Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 40
1.
Eur Heart J Case Rep ; 8(6): ytae226, 2024 Jun.
Article En | MEDLINE | ID: mdl-38845809

Background: Iatrogenic aortic valve injury during cardiovascular catheterization interventions is extremely rare. Severe aortic regurgitation that ensues can be catastrophic and the management is typically with surgical valve replacement or repair. Percutaneous management of native pure aortic regurgitation is difficult due to anatomical challenges and the limitations of current transcatheter heart valve technology to anchor in the absence of leaflet or annular calcification. Case Summary: An 82-year-old female underwent rotational atherectomy (RA) for a severely calcified stenosis of the left anterior descending artery. The patient was discharged well following placement of two drug eluting stents. She represented to hospital 7 days later with acute pulmonary oedema. Bedside transthoracic echocardiography demonstrated new, severe AR with preserved left ventricular size and function. Review of the prior percutaneous coronary intervention revealed significant trauma to the aortic valve during RA, with contrast seen refluxing into the LV during diastole, evolving throughout the procedure. Given the patient was not an operative candidate, an oversized transcatheter aortic valve was successfully implanted. In the post-operative setting, the patient suffered a stroke. Extensive hypoattenuated leaflet thickening (HALT) and thrombus was seen on dedicated 4D CT imaging. She made full neurological recovery and valve function returned to normal following a period of anticoagulation. Conclusion: Although iatrogenic aortic valve laceration is rare, this case highlights several important learning points including the importance of good guide catheter support during RA; the feasibility of Transcatheter Aortic Valve Replacement for pure native AR; and the detection and management of HALT.

2.
JACC Case Rep ; 29(10): 102330, 2024 May 15.
Article En | MEDLINE | ID: mdl-38601844

This clinical case describes a subacute presentation of decompensated heart failure secondary to an iatrogenic left ventricle-to-coronary sinus fistula after sequential mitral valve surgical procedures. Computed tomography was used to select an unconventional hybrid transapical access approach and facilitate successful closure using a vascular plug.

6.
JACC Cardiovasc Interv ; 16(6): 681-689, 2023 03 27.
Article En | MEDLINE | ID: mdl-36990558

BACKGROUND: The self-expanding, intra-annular Navitor (Abbott Structural Heart) valve includes an outer cuff to reduce paravalvular leak (PVL) and large stent cells for future coronary access. OBJECTIVES: The purpose of the PORTICO NG (Evaluation of the Portico NG [Next Generation] Transcatheter Aortic Valve in High and Extreme Risk Patients With Symptomatic Severe Aortic Stenosis) study is to evaluate the safety and effectiveness of the Navitor valve in patients with symptomatic, severe aortic stenosis who are at high or extreme surgical risk. METHODS: PORTICO NG is a prospective, multicenter, global study with follow-up at 30 days, 1 year, and annually through 5 years. The primary endpoints are all-cause mortality and moderate or greater PVL at 30 days. Valve Academic Research Consortium-2 events and valve performance are assessed by an independent clinical events committee and echocardiographic core laboratory. RESULTS: A total of 260 subjects were treated at 26 clinical sites across Europe, Australia, and the United States between September 2019 and August 2022. The mean age was 83.4 ± 5.4 years, 57.3% were female, and the average Society of Thoracic Surgeons score was 3.9% ± 2.1%. At 30 days, the rate of all-cause mortality was 1.9%, and no subjects had moderate or greater PVL. The rate of disabling stroke was 1.9%, life-threatening bleeding was 3.8%, stage 3 acute kidney injury was 0.8%, major vascular complications were 4.2%, and new permanent pacemaker implantation was 19.0%. Hemodynamic performance included a mean gradient of 7.4 ± 3.5 mm Hg and an effective orifice area of 2.00 ± 0.47 cm2. CONCLUSIONS: The Navitor valve is safe and effective for the treatment of subjects with severe aortic stenosis who are at high or greater risk for surgery, which is supported by low rates of adverse events and PVL. (Evaluation of the Portico NG [Next Generation] Transcatheter Aortic Valve in High and Extreme Risk Patients With Symptomatic Severe Aortic Stenosis [PORTICO NG]; NCT04011722).


Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Female , United States , Aged , Aged, 80 and over , Male , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Transcatheter Aortic Valve Replacement/adverse effects , Prospective Studies , Treatment Outcome , Postoperative Complications/etiology , Heart Valve Prosthesis/adverse effects , Prosthesis Design
7.
EuroIntervention ; 19(3): 248-255, 2023 Jun 19.
Article En | MEDLINE | ID: mdl-36895190

BACKGROUND: The Navitor transcatheter heart valve (THV) is a self-expanding valve, with an intra-annular leaflet position and an outer cuff intended to reduce paravalvular leak (PVL). AIMS: The aim of the PORTICO NG Study is to assess the safety and performance of the Navitor THV in patients with symptomatic, severe aortic stenosis who are at high or extreme surgical risk. METHODS: PORTICO NG is a prospective, multicentre, global, single-arm, investigational study with follow-up at 30 days, 1 year, and annually up to 5 years. The primary endpoints are all-cause mortality and moderate or greater PVL at 30 days. Valve Academic Research Consortium-2 events and valve performance are assessed by an independent clinical events committee and echocardiographic core laboratory. RESULTS: A total of 120 high- or extreme-risk subjects (age 83.5±5.4 years; 58.3% female; Society of Thoracic Surgeons score 4.0±2.0%) were enrolled in the European conformity (CE) mark cohort. Procedural success was high at 97.5%. At 30 days, the rate of all-cause mortality was 0%, and no subjects had moderate or greater PVL. The rate of disabling stroke was 0.8%, life-threatening bleeding was 2.5%, stage 3 acute kidney injury 0%, major vascular complications 0.8%, and new pacemaker implantation 15.0%. At 1 year, the rates of all-cause mortality and disabling stroke were 4.2% and 0.8%, respectively. The rate of moderate PVL was 1.0% at 1 year. Haemodynamic performance with a mean gradient of 7.5±3.2 mmHg and effective orifice area of 1.9±0.4 cm2 was sustained up to 1 year. CONCLUSIONS: The PORTICO NG Study demonstrates low rates of adverse events and PVL up to 1 year in patients at high or extreme surgical risk, confirming the safety and efficacy of the Navitor THV system.


Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Prospective Studies , Treatment Outcome , Prosthesis Design , Aortic Valve Stenosis/surgery , Stroke/etiology
8.
AsiaIntervention ; 8(1): 42-49, 2022 Mar.
Article En | MEDLINE | ID: mdl-35350794

Aims: Calcified coronary stenoses are a serious impediment to optimal stent expansion and can lead to stent failure and catastrophic adverse outcomes. We hereby present early Australian experience with intravascular lithotripsy for the treatment of calcific lesions in acute and chronic coronary syndromes. Methods and results: This was a single-centre retrospective study of all patients treated with intravascular lithotripsy (IVL) between October 2019 and June 2021. Patient demographics, procedural variables, and treatment safety/efficacy outcomes were evaluated. During this period, there were 40 patients and 41 coronary lesions with IVL-assisted percutaneous coronary intervention (PCI) (70% male; mean age 72.8±9.5 years). Indications for PCI were acute coronary syndromes in 25 patients (62.5%), and stable angina in 15 patients (37.5%). Upfront IVL usage occurred in 5% of cases with the rest being bailout procedures due to suboptimal initial balloon predilatation or stent underexpansion. Angiographic success (<20% residual stenosis) occurred in 37 cases (92.5%), with mean residual stenosis of 8.25%±8.5%. Two patients experienced procedural complications (5%). Conclusions: IVL appears to be a safe and effective modality in modifying coronary calcium to achieve optimal stent expansion in real-world practice. This device obviates the need for more complex lesion preparation strategies such as rotational or orbital atherectomy.

10.
Heart Lung Circ ; 31(4): 559-565, 2022 Apr.
Article En | MEDLINE | ID: mdl-34916154

BACKGROUND: Indications for transcatheter aortic valve implantation (TAVI) in aortic stenosis are expanding and the life expectancy of patients following TAVI is increasing. Determining the long-term durability of TAVI valves is therefore important. Rates of long-term (≥5 years) structural valve deterioration (SVD) vary widely and there are currently no comparable data from Australia. The aim herein was to determine the incidence of haemodynamic SVD and bioprosthetic valve failure (BVF) using recently standardised definitions in a Western Australian cohort after at least 5 years. METHODS: This is a retrospective cohort study of consecutive patients undergoing TAVI at Royal Perth Hospital between January 2009 and January 2015. Of 211 patients, 55 survived ≥5 years and had echocardiographic data available for review. Median time to the echocardiogram was 5.9 years (max 7.8 years); 49% male, mean age 83 years. RESULTS: Of the 55 survivors who had echocardiograms available ≥5 years after TAVI, four (9%) had moderate haemodynamic SVD and one (2%) had severe SVD and BVF. CONCLUSIONS: Our results suggest excellent long-term durability of contemporary TAVI valves in an Australian cohort with very low incidence of SVD and BVF. These findings add confidence to the expanding applications of TAVI valves.


Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Australia/epidemiology , Bioprosthesis/adverse effects , Echocardiography , Female , Follow-Up Studies , Humans , Male , Prosthesis Failure , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
11.
BMJ Case Rep ; 14(11)2021 Nov 23.
Article En | MEDLINE | ID: mdl-34815226

A 32-year-old, 11-week pregnant African woman with known rheumatic heart disease presented to the emergency department with worsening shortness of breath on exertion. She had undergone a double bioprosthetic valve replacement and left atrial appendage resection 8 years prior for severe mitral stenosis, moderate mitral regurgitation and moderate aortic regurgitation. A transo-oesophageal echocardiography at this presentation confirmed a morphologically calcified and stenosed mitral bioprosthesis, with moderate stenosis of her aortic bioprosthesis. Her multidisciplinary team, including cardiologists, cardiothoracic surgeons and obstetricians, came to a consensus decision to proceed with a transseptal transcatheter valve implantation within the mitral valve prosthesis (valve-in-valve implantation). Transthoracic echocardiography performed 2 months post procedure showed satisfactory mitral valve gradients and at 30 weeks' gestation, she successfully delivered her fifth child. 2 years later, the valve in valve complex is still functioning well.


Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Adult , Cardiac Catheterization , Child , Female , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/surgery , Pregnancy , Prosthesis Design , Prosthesis Failure , Treatment Outcome
13.
Eur Heart J Case Rep ; 5(12): ytab482, 2021 Dec.
Article En | MEDLINE | ID: mdl-34993407

BACKGROUND: Despite increasing use of percutaneous coronary intervention and stenting, septic complications such as coronary stent infections are rare. We report a unique case of mitral valve infective endocarditis and associated coronary stent infection which emerged 6 months after index stent insertion. CASE SUMMARY: A 56-year-old previously healthy man underwent percutaneous coronary intervention and stenting of left circumflex (LCx) coronary artery in the setting of non-ST-segment elevation myocardial infarction. Six months later, he represented with inferior ST-segment elevation myocardial infarction and was found to have a coronary pseudoaneurysm of stented segment of LCx. The pseudoaneurysm was treated with insertion of a covered stent, and immediately following that he developed sepsis with methicillin-sensitive Staphylococcus aureus bacteraemia. Comprehensive work-up resulted in the diagnosis of mitral valve endocarditis complicated by coronary stent infection and myocardial abscess formation. He was managed with initial prolonged systemic antibiotic treatment followed by mitral valve replacement. Post-operative course was uneventful with a short duration of oral antibiotics. At 6-year follow-up, the patient was well with the satisfactory echocardiographic result. DISCUSSION: This is a very rare case of mitral valve endocarditis with extensive cardiac involvement including coronary stent infection and surrounding myocardial abscess. Stents can act as an ideal vector for bacterial adherence from which bacteria could spread to the arterial wall and adjacent myocardium. This case suggests a potential complication of delayed endothelialization and risk of infective complication due to bacterial seeding or embolization.

14.
JACC Cardiovasc Interv ; 13(21): 2467-2478, 2020 11 09.
Article En | MEDLINE | ID: mdl-33153563

OBJECTIVES: The aim of this study was to characterize the safety profile of an intra-annular self-expanding valve with a next-generation low-profile delivery system (DS). BACKGROUND: Key design modifications to the FlexNav DS include the addition of a hydrophilic-coated, integrated sheath and stability layer to facilitate gradual, controlled deployment in vessels with diameter ≥5 mm. METHODS: Patients were pooled from 2 concurrent prospective, multicenter, single-arm studies (FlexNav DS arm of PORTICO IDE [Portico Re-Sheathable Transcatheter Aortic Valve System U.S. IDE Trial] [n = 134] and the FlexNav EU CE Mark Study [n = 46]) for the analysis. The primary endpoint was Valve Academic Research Consortium-2-defined major vascular complications at 30 days. Clinical outcomes and valve performance were assessed through 30 days by an independent clinical events committee and an echocardiography core laboratory, respectively. RESULTS: One hundred forty high-risk and 40 extreme-risk subjects enrolled between October 15, 2018, and December 10, 2019, from 28 sites in the United States, Australia, and Europe who underwent attempted transfemoral Portico valve implantation were included. The mean age was 85.1 ± 5.6 years, 60% were women, the mean Society of Thoracic Surgeons score was 5.3%, and 96.1% presented with ≥1 frailty factor. Technical device success was 96.7%. At 30 days, the rate of major vascular complications was 5.0%, with 4.4% of complications adjudicated as access site-related (3.3% transcatheter aortic valve replacement DS access site-related). Death (0.6%) and disabling stroke (1.1%) were rare. The rate of new permanent pacemaker implantation was 15.4%. Echocardiography revealed a mean gradient of 7.1 ± 3.2 mm Hg, mean valve area of 1.77 ± 0.41 cm2, and a 4.1% rate of moderate paravalvular leak at 30 days. CONCLUSIONS: Portico valve implantation with the FlexNav DS was associated with an excellent safety profile at 30 days.


Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Australia , Europe , Female , Humans , Male , Prospective Studies , Prosthesis Design , Severity of Illness Index , Time Factors , Treatment Outcome , United States
15.
Heart Lung Circ ; 29(12): 1839-1846, 2020 Dec.
Article En | MEDLINE | ID: mdl-32712017

BACKGROUND: To determine the safety and performance of the SAPIEN XT transcatheter heart valve (THV) in Australian patients with severe aortic stenosis (AS) and intermediate surgical risk. METHODS: Eligible patients in this multi-centre, prospective, consecutively enrolled, non-randomised, clinical trial, received transcatheter aortic valve replacement via femoral artery access. Follow-up visits were at discharge, 30 days, and 6, 12, and 24 months. The primary endpoint was Valve Academic Research Consortium-2 composite safety at 30 days: all-cause mortality, all stroke, life-threatening bleeding, acute kidney injury-Stage 3, coronary artery obstruction requiring intervention, major vascular complication, and valve-related dysfunction requiring repeat procedure. Other endpoints were device success (successful vascular access, delivery, and deployment; correct position; intended performance mean aortic valve gradient <20 mmHg, mild or less paravalvular aortic regurgitation [PAR]; and only one valve implanted) and New York Heart Association functional class (NYHA). Kaplan-Meier (KM) estimates were calculated for the primary endpoint. RESULTS: At baseline, mean patient (N=199) age was 85.5 years, mean Society of Thoracic Surgeon score was 5.9, and 78.4% were in NYHA class III/IV. The primary composite endpoint KM estimate was 12.1%. Device success was 88.8%. SAPIEN XT was implanted in the proper location in 98.5% (n=2: valve-in-valve procedures, n=1: no implant due to left main coronary artery occlusion). No device malfunctions were reported. The post procedure PAR was mild or less in 93.8% of patients. Mean aortic gradient decreased from baseline (50.0 mmHg) to 2 years (10.3 mmHg). Most patients (90.9%) were in NYHA class I/II at 30 days. New permanent pacemaker rate was 8.1%. Stroke at 30 days was 3.5% (1.5% disabling). CONCLUSION: SAPIEN XT was safe and improved heart failure symptoms and valve haemodynamics in this cohort of Australian patients.


Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Cardiac Catheterization/methods , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnosis , Australia , Echocardiography , Female , Femoral Artery , Humans , Male , Prospective Studies , Prosthesis Design , Risk Factors , Severity of Illness Index , Treatment Outcome
16.
Lancet ; 396(10252): 669-683, 2020 09 05.
Article En | MEDLINE | ID: mdl-32593323

BACKGROUND: Randomised trial data assessing the safety and efficacy of the self-expanding intra-annular Portico transcatheter aortic valve system (Abbott Structural Heart, St Paul, MN, USA) compared with any commercially available valves are needed to compare performance among designs. METHODS: In this prospective, multicentre, non-inferiority, randomised controlled trial (the Portico Re-sheathable Transcatheter Aortic Valve System US Investigational Device Exemption trial [PORTICO IDE]), high and extreme risk patients with severe symptomatic aortic stenosis were recruited from 52 medical centres experienced in performing transcatheter aortic valve replacement in the USA and Australia. Patients were eligible if they were aged 21 years or older, in New York Heart Association functional class II or higher, and had severe native aortic stenosis. Eligible patients were randomly assigned (1:1) using permuted block randomisation (block sizes of 2 and 4) and stratified by clinical investigational site, surgical risk cohort, and vascular access method, to transcatheter aortic valve replacement with the first generation Portico valve and delivery system or a commercially available valve (either an intra-annular balloon-expandable Edwards-SAPIEN, SAPIEN XT, or SAPIEN 3 valve [Edwards LifeSciences, Irvine, CA, USA]; or a supra-annular self-expanding CoreValve, Evolut-R, or Evolut-PRO valve [Medtronic, Minneapolis, MN, USA]). Investigational site staff, implanting physician, and study participant were unmasked to treatment assignment. Core laboratories and clinical event assessors were masked to treatment allocation. The primary safety endpoint was a composite of all-cause mortality, disabling stroke, life-threatening bleeding requiring transfusion, acute kidney injury requiring dialysis, or major vascular complication at 30 days. The primary efficacy endpoint was all-cause mortality or disabling stroke at 1 year. Clinical outcomes and valve performance were assessed up to 2 years after the procedure. Primary analyses were by intention to treat and the Kaplan-Meier method to estimate event rates. The non-inferiority margin was 8·5% for primary safety and 8·0% for primary efficacy endpoints. This study is registered with ClinicalTrials.gov, NCT02000115, and is ongoing. FINDINGS: Between May 30 and Sept 12, 2014, and between Aug 21, 2015, and Oct 10, 2017, with recruitment paused for 11 months by the funder, we recruited 1034 patients, of whom 750 were eligible and randomly assigned to the Portico valve group (n=381) or commercially available valve group (n=369). Mean age was 83 years (SD 7) and 395 (52·7%) patients were female. For the primary safety endpoint at 30 days, the event rate was higher in the Portico valve group than in the commercial valve group (52 [13·8%] vs 35 [9·6%]; absolute difference 4·2, 95% CI -0·4 to 8·8 [upper confidence bound {UCB} 8·1%]; pnon-inferiority=0·034, psuperiority=0·071). At 1 year, the rates of the primary efficacy endpoint were similar between the groups (55 [14·8%] in the Portico group vs 48 [13·4%] in the commercial valve group; difference 1·5%, 95% CI -3·6 to 6·5 [UCB 5·7%]; pnon-inferiority=0·0058, psuperiority=0·50). At 2 years, rates of death (80 [22·3%] vs 70 [20·2%]; p=0·40) or disabling stroke (10 [3·1%] vs 16 [5·0%]; p=0·23) were similar between groups. INTERPRETATION: The Portico valve was associated with similar rates of death or disabling stroke at 2 years compared with commercial valves, but was associated with higher rates of the primary composite safety endpoint including death at 30 days. The first-generation Portico valve and delivery system did not offer advantages over other commercially available valves. FUNDING: Abbott.


Aortic Valve Stenosis/surgery , Heart Valve Prosthesis , Mortality , Postoperative Complications/epidemiology , Prosthesis Design , Stroke/epidemiology , Transcatheter Aortic Valve Replacement , Acute Kidney Injury/epidemiology , Acute Kidney Injury/therapy , Aged , Aged, 80 and over , Australia , Blood Transfusion , Cause of Death , Female , Humans , Male , Postoperative Complications/therapy , Postoperative Hemorrhage/epidemiology , Postoperative Hemorrhage/therapy , Renal Dialysis , Severity of Illness Index , Treatment Outcome , United States
18.
J Am Coll Cardiol ; 69(21): 2579-2589, 2017 May 30.
Article En | MEDLINE | ID: mdl-28330793

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is being increasingly performed in patients with bicuspid aortic valve stenosis (AS). OBJECTIVES: This study sought to compare the procedural and clinical outcomes in patients with bicuspid versus tricuspid AS from the Bicuspid AS TAVR multicenter registry. METHODS: Outcomes of 561 patients with bicuspid AS and 4,546 patients with tricuspid AS were compared after propensity score matching, assembling 546 pairs of patients with similar baseline characteristics. Procedural and clinical outcomes were recorded according to Valve Academic Research Consortium-2 criteria. RESULTS: Compared with patients with tricuspid AS, patients with bicuspid AS had more frequent conversion to surgery (2.0% vs. 0.2%; p = 0.006) and a significantly lower device success rate (85.3% vs. 91.4%; p = 0.002). Early-generation devices were implanted in 320 patients with bicuspid and 321 patients with tricuspid AS, whereas new-generation devices were implanted in 226 and 225 patients with bicuspid and tricuspid AS, respectively. Within the group receiving early-generation devices, bicuspid AS had more frequent aortic root injury (4.5% vs. 0.0%; p = 0.015) when receiving the balloon-expanding device, and moderate-to-severe paravalvular leak (19.4% vs. 10.5%; p = 0.02) when receiving the self-expanding device. Among patients with new-generation devices, however, procedural results were comparable across different prostheses. The cumulative all-cause mortality rates at 2 years were comparable between bicuspid and tricuspid AS (17.2% vs. 19.4%; p = 0.28). CONCLUSIONS: Compared with tricuspid AS, TAVR in bicuspid AS was associated with a similar prognosis, but lower device success rate. Procedural differences were observed in patients treated with the early-generation devices, whereas no differences were observed with the new-generation devices.


Aortic Valve Stenosis/surgery , Aortic Valve/abnormalities , Heart Valve Diseases/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/methods , Tricuspid Valve/surgery , Aged , Aortic Valve/surgery , Aortic Valve Stenosis/mortality , Bicuspid Aortic Valve Disease , Female , Global Health , Humans , Male , Retrospective Studies , Survival Rate/trends , Treatment Outcome , Tricuspid Valve/abnormalities
19.
J Am Coll Cardiol ; 68(11): 1195-1205, 2016 09 13.
Article En | MEDLINE | ID: mdl-27609682

BACKGROUND: Few studies have evaluated the clinical outcomes of transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS). Particularly, limited data exist comparing the results of TAVR with new-generation devices versus early-generation devices. OBJECTIVES: This study sought to evaluate the clinical outcomes of TAVR for bicuspid AS with early- and new-generation devices. METHODS: The Bicuspid TAVR Registry is an international multicenter study enrolling consecutive patients with bicuspid AS undergoing TAVR between April 2005 and May 2015. RESULTS: Of 301 patients, 199 patients (71.1%) were treated with early-generation devices (Sapien XT [Edwards Lifesciences Corporation, Irvine, California]: n = 87; CoreValve [Medtronic, Minneapolis, Minnesota]: n = 112) and 102 with new-generation devices (Sapien 3 [Edwards Lifesciences Corporation]: n = 91; Lotus [Boston Scientific Corporation, Marlborough, Massachusetts]: n = 11). The mean Society of Thoracic Surgeons score was 4.7 ± 5.2 without significant differences between groups (4.6 ± 5.1 vs. 4.9 ± 5.4; p = 0.57). Overall, all-cause mortality rates were 4.3% at 30 days and 14.4% at 1 year. Moderate or severe paravalvular leak was absent and significantly less frequent with new-generation compared to early-generation devices (0.0% vs. 8.5%; p = 0.002), which resulted in a higher device success rate (92.2% vs. 80.9%; p = 0.01). There were no differences between early- and new-generation devices in stroke (2.5% vs. 2.0%; p > 0.99), life-threatening bleeding (3.5% vs. 2.9%; p > 0.99), major vascular complication (4.5% vs. 2.9%; p = 0.76), stage 2 to 3 acute kidney injury (2.5% vs. 2.9%; p > 0.99), early safety endpoints (15.1% vs. 10.8%; p = 0.30), and 30-day all-cause mortality (4.5% vs. 3.9%; p > 0.99). CONCLUSIONS: The clinical outcomes of TAVR in patients with bicuspid AS were favorable. New-generation devices were associated with less paravalvular leak and, hence, a higher device success rate than early-generation devices. (The Bicuspid Aortic Stenosis Following Transcatheter Aortic Valve Replacement Registry [Bicuspid TAVR]; NCT02394184).


Aortic Valve Stenosis/surgery , Aortic Valve/abnormalities , Heart Valve Diseases/surgery , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aortic Valve/surgery , Aortic Valve Stenosis/etiology , Bicuspid Aortic Valve Disease , Equipment Design , Female , Heart Valve Diseases/complications , Humans , Male
...