Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Anal Chem ; 2024 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-39305236

RESUMEN

The traditional magnetic relaxation switching (MRS) sensors have excellent sensitivity, but their stability is poor because the magnetic relaxation signal is easily affected by the external magnetic field or environmental oxidation. In this study, a highly stable hydrogel bead-based MRS (Gel-MRS) sensor was established for the accurate and sensitive detection of Cd2+ in rice. A pH-responsive hydrogel bead was applied as a core element for the target stimulus and transverse relaxation signal transduction. The stability experiments showed that the transverse relaxation time (T2) change of the Gel-MRS sensor was one-seventh that of traditional magnetic nanoparticles under an external magnetic field and less than a fifth that of Fe2+/Fe3+ conversion in air. The excellent stability was due to the fact that T2 of the Gel-MRS sensor came from the swelling system mediated by pH rather than the traditional aggregation/dispersion or Fe2+/Fe3+ conversion of magnetic nanoparticles. In addition, the target Cd2+ could exclusively trigger a pH response of the hydrogel beads, altering the T2, thus resulting in excellent relaxation properties (R2 = 56.89) and pH responsiveness of the Gel-MRS sensor. The swelling process of the hydrogel beads followed quasi-second-order dynamics. The Gel-MRS sensor demonstrated a remarkable limit of detection as low as 0.009 ng/mL for Cd2+, with a linear range of 0.01-5 ng/mL. The excellent stability and sensitivity made the Gel-MRS sensor have great application potential in food and environmental detection.

2.
J Agric Food Chem ; 72(22): 12832-12841, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38785419

RESUMEN

Capsaicin (CAP) is a primary indicator for assessing the level of pungency. Herein, iron-based single-atom nanozymes (SAzymes) (Fe/NC) with exceptional oxidase-like activity were used to construct an immunosensor for CAP analysis. Fe/NC could imitate oxidase actions by transforming O2 to •O2- radicals in the absence of hydrogen peroxide (H2O2), which could avoid complex operations and unstable results. By regulating the Fe atom loads, an optimal Fe0.7/NC atom usage rate could improve the catalytic activity (Michaelis-Menten constant (Km) = 0.09 mM). Fe0.7/NC was integrated with goat antimouse IgG by facile mix incubation to develop a competitive enzyme-linked immunosorbent assay (ELISA). Our Fe0.7/NC immunosensing platform is anticipated to outperform the conventional ELISA in terms of stability and shelf life. The proposed immunosensor provided color responses across 0.01-1000 ng/mL CAP concentrations, with a detection limit of 0.046 ng/mL. Fe/NC may have potential as nanozymes for CAP detection in spicy foods, with promising applications in food biosensing.


Asunto(s)
Técnicas Biosensibles , Capsaicina , Capsaicina/análisis , Capsaicina/química , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Oxidorreductasas/química , Ensayo de Inmunoadsorción Enzimática/métodos , Hierro/química , Hierro/análisis , Límite de Detección , Peróxido de Hidrógeno/química , Análisis de los Alimentos/métodos
3.
Soft Robot ; 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38387016

RESUMEN

Soft robotic grippers and hands offer adaptability, lightweight construction, and enhanced safety in human-robot interactions. In this study, we introduce vacuum-actuated soft robotic finger joints to overcome their limitations in stiffness, response, and load-carrying capability. Our design-optimized through parametric design and three-dimensional (3D) printing-achieves high stiffness using vacuum pressure and a buckling mechanism for large bending angles (>90°) and rapid response times (0.24 s). We develop a theoretical model and nonlinear finite-element simulations to validate the experimental results and provide valuable insights into the underlying mechanics and visualization of the deformation and stress field. We showcase versatile applications of the buckling joints: a three-finger gripper with a large lifting ratio (∼96), a five-finger robotic hand capable of replicating human gestures and adeptly grasping objects of various characteristics in static and dynamic scenarios, and a planar-crawling robot carrying loads 30 times its weight at 0.89 body length per second (BL/s). In addition, a jellyfish-inspired robot crawls in circular pipes at 0.47 BL/s. By enhancing soft robotic grippers' functionality and performance, our study expands their applications and paves the way for innovation through 3D-printed multifunctional buckling joints.

4.
Food Chem ; 443: 138537, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38309027

RESUMEN

Aflatoxin B1 (AFB1) can accumulate in different organs or tissues and seriously harm humans. Traditional magnetic relaxation switching (MRS) sensors have relatively low sensitivity, but are complex to use. Rapid small-trace molecule analysis in complex samples is challenging. In this study, we used a gadolinium-based metal-organic framework (Gd-MOF) and ultra-small superparamagnetic iron oxide (USPIO) assembly to develop a magnetic resonance tuning-magnetic relaxation switching (MRET-MRS) sensor to improve conventional MRS sensor sensitivity and simplify operational steps in complex samples. Importantly, the local magnetic field generated by USPIO interfered with Gd-MOF electron spin fluctuation and directly affected dipole-dipole interactions between Gd electrons and water molecules, thus rendering relaxation signal changes more sensitive. The sensitivity (0.54 pg mL-1) was 833 times more sensitive than that of a conventional MRS sensor (0.45 ng mL-1). Finally, a convenient one-step detection approach can be achieved by mixing antigen/antibody functionalized Gd-MOF/USPIO and target samples.


Asunto(s)
Dextranos , Nanopartículas de Magnetita , Estructuras Metalorgánicas , Humanos , Gadolinio , Aflatoxina B1 , Espectroscopía de Resonancia Magnética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA