Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 119
Filtrar
1.
Ann Lab Med ; 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38953115

RESUMEN

Background: Healthcare 4.0. refers to the integration of advanced technologies, such as artificial intelligence (AI) and big data analysis, into the healthcare sector. Recognizing the impact of Healthcare 4.0 technologies in laboratory medicine (LM), we seek to assess the overall awareness and implementation of Healthcare 4.0 among members of the Korean Society for Laboratory Medicine (KSLM). Methods: A web-based survey was conducted using an anonymous questionnaire. The survey comprised 36 questions covering demographic information (seven questions), big data (10 questions), and AI (19 questions). Results: In total, 182 (17.9%) of 1,017 KSLM members participated in the survey. Thirty-two percent of respondents considered AI to be the most important technology in LM in the era of Healthcare 4.0, closely followed by 31% who favored big data. Approximately 80% of respondents were familiar with big data but had not conducted research using it, and 71% were willing to participate in future big data research conducted by the KSLM. Respondents viewed AI as the most valuable tool in molecular genetics within various divisions. More than half of the respondents were open to the notion of using AI as assistance rather than a complete replacement for their roles. Conclusions: This survey highlighted KSLM members' awareness of the potential applications and implications of big data and AI. We emphasize the complexity of AI integration in healthcare, citing technical and ethical challenges leading to diverse opinions on its impact on employment and training. This highlights the need for a holistic approach to adopting new technologies.

2.
Clin Chem ; 70(4): 669-679, 2024 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-38385453

RESUMEN

BACKGROUND: The harmonization status of most tumor markers (TMs) is unknown. We report a feasibility study performed to determine whether external quality assessment (EQA) programs can be used to obtain insights into the current harmonization status of the tumor markers α-fetoprotein (AFP), prostate specific antigen (PSA), carcinoembryonic antigen (CEA), cancer antigen (CA)125, CA15-3 and CA19-9. METHODS: EQA sample results provided by 6 EQA providers (INSTAND [Germany], Korean Association of External Quality Assessment Service [KEQAS, South Korea], National Center for Clinical Laboratories [NCCL, China], United Kingdom National External Quality Assessment Service [UK NEQAS, United Kingdom], Stichting Kwaliteitsbewaking Medische Laboratoriumdiagnostiek [SKML, the Netherlands], and the Royal College of Pathologists of Australasia Quality Assurance Programs [RCPAQAP, Australia]) between 2020 and 2021 were used. The consensus means, calculated from the measurement procedures present in all EQA programs (Abbott Alinity, Beckman Coulter DxI, Roche Cobas, and Siemens Atellica), was used as reference values. Per measurement procedure, the relative difference between consensus mean for each EQA sample and the mean of all patient-pool-based EQA samples were calculated and compared to minimum, desirable, and optimal allowable bias criteria based on biological variation. RESULTS: Between 19040 (CA15-3) and 25398 (PSA) individual results and 56 (PSA) to 76 (AFP) unique EQA samples were included in the final analysis. The mean differences with the consensus mean of patient-pool-based EQA samples for all measurement procedures were within the optimum bias criterion for AFP, the desirable bias for PSA, and the minimum bias criterion for CEA. However, CEA results <8 µg/L exceeded the minimum bias criterion. For CA125, CA15-3, and CA19-9, the harmonization status was outside the minimum bias criterion, with systematic differences identified. CONCLUSIONS: This study provides relevant information about the current harmonization status of 6 tumor markers. A pilot harmonization investigation for CEA, CA125, CA15-3, and CA19-9 would be desirable.


Asunto(s)
Biomarcadores de Tumor , Antígeno Carcinoembrionario , Masculino , Humanos , alfa-Fetoproteínas/análisis , Antígeno Prostático Específico , Antígeno CA-19-9 , Estudios de Factibilidad , Mucina-1 , Antígeno Ca-125
3.
Pract Lab Med ; 38: e00347, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38188654

RESUMEN

Background: Vitamin D (vit-D) deficiency is highly prevalent in the Korean population, highlighting the need for accurate measurements. In this study, the interferences by endogenous and cross-reactive substances were compared between routine vit-D immunoassays and mass spectrometry (MS) methods. Methods: Two MS methods and 4 immunoassays from different manufacturers (Abbott, Beckman Coulter, Roche, Siemens) were compared. Residual samples that were icteric, lipemic, hemolyzed, high in rheumatoid factor, from myeloma patients, or patients undergoing hemodialysis were collected. Also, 4 levels of National Institute of Standards and Technology (NIST) Standard Reference Material 972a, and 12 samples serially spiked with 3-epi-25-OH-D3 were prepared. Results: Significant interferences were observed in hemolytic (Roche), icteric (Beckman and Siemens) and lipemic samples (all 4 immunoassays). Level 4 NIST material and 3-epi-25-OH-D3-spiked samples induced significant cross-reactivity, yielding higher total vit-D measurements in non-epimer-separating MS methods, and both the Beckman and Roche immunoassays. Conclusion: Most observed interferences were consistent with manufacturers' claims, but overall improvement of immunoassay bias limits is required. Awareness of potential interference is important to increase the accuracy of vit-D measurements. Moreover, care is due when interpreting vit-D results of newborns, infants and less commonly, pregnant women, who are known to have physiologically high levels of the highly cross-reactive 3-epi-25-OH-D3.

4.
Diagnostics (Basel) ; 14(2)2024 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-38275478

RESUMEN

We evaluated the diagnostic performance of the STANDARD i-Q COVID-19 Ag Test, which was developed to detect viral antigens, using nasal and oral swabs. Sixty positive and 100 negative samples were analyzed. We determined the distribution of the Ct values according to the day of sample collection after symptom onset, the diagnostic performance of the total samples and subgroups separated by Ct value or time of sample collection, and the Ct value at which maximal accuracy was expected. No differences were observed in Ct values, except for the samples obtained on the day of symptom onset. The diagnostic sensitivity and specificity of the oral swabs were 75.0 and 100.0%, respectively, whereas those of the nasal swabs were 85.0 and 98.0%, respectively. The sensitivity was higher in samples with a high viral load collected earlier than those collected later, although the difference was not significant. False-negative results were confirmed in all samples with a Ct value ≥ 30.0. These results indicate that tests using oral and nasal swabs are helpful for diagnosing acute symptomatic cases with suspected high viral loads. Our tests exhibited relatively low sensitivity but high specificity rates, indicating the need to assess negative antigen test results.

5.
Clin Chem Lab Med ; 62(5): 958-966, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38000045

RESUMEN

OBJECTIVES: White blood cell (WBC)-related flags are essential for detecting abnormal cells including blasts in automated hematology analyzers (AHAs). Cell population data (CPD) may characterize each WBC population, and customized CPD rules can be also useful for detecting blasts. We evaluated the performance of WBC-related flags, customized CPD rules, and their combination for detecting blasts on the Beckman Coulter DxH 900 AHA (DxH 900, Beckman Coulter, Miami, Florida, USA). METHODS: In a total of 239 samples from patients with hematologic diseases, complete blood count on DxH 900 and manual slide review (MSR) were conducted. The sensitivity, specificity, and efficiency of the five WBC-related flags, nine customized CPD rules, and their combination were evaluated for detecting blasts, in comparison with MSR. RESULTS: Blasts were detected by MSR in 40 out of 239 (16.7 %) samples. The combination of flags and CPD rules showed the highest sensitivity compared with each of flags and CPD rules for detecting blasts (97.5 vs. 72.5 % vs. 92.5 %). Compared with any flag, the combination of flags and CPD rules significantly reduced false-negative samples from 11 to one for detecting blasts (27.5 vs. 2.5 %, p=0.002). CONCLUSIONS: This is the first study that evaluated the performance of both flags and CPD rules on DxH 900. The customized CPD rules as well as the combination of flags and CPD rules outperformed WBC-related flags for detecting blasts on DxH 900. The customized CPD rules can play a complementary role for improving the capability of blast detection on DxH 900.


Asunto(s)
Enfermedades Hematológicas , Hematología , Humanos , Recuento de Células Sanguíneas , Enfermedades Hematológicas/diagnóstico , Leucocitos , Recuento de Leucocitos
6.
Diagnostics (Basel) ; 13(14)2023 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-37510116

RESUMEN

We explored the utility of novel biomarkers, presepsin and interferon-λ3 (IFN-λ3), for predicting disease severity and clinical outcomes in hospitalized Coronavirus (COVID-19) patients. In a total of 55 patients (non-critical, n = 16; critical, n = 39), presepsin and IFN-λ3 were compared with sequential organ failure assessment (SOFA) scores and age. Disease severity and clinical outcomes (in-hospital mortality, intensive care unit admission, ventilator use, and kidney replacement therapy) were analyzed using receiver operating characteristic (ROC) curves. In-hospital mortality was also analyzed using the Kaplan-Meier method with hazard ratios (HR). SOFA scores, age, presepsin, and IFN-λ3 predicted disease severity comparably (area under the curve [AUC], 0.67-0.73). SOFA score and IFN-λ3 predicted clinical outcomes comparably (AUC, 0.68-0.88 and 0.66-0.74, respectively). Presepsin predicted in-hospital mortality (AUC = 0.74). The combination of presepsin and IFN-λ3 showed a higher mortality risk than SOFA score or age (HR [95% confidence interval, CI], 6.7 [1.8-24.1]; 3.6 [1.1-12.1]; 2.8 [0.8-9.6], respectively) and mortality rate further increased when presepsin and IFN-λ3 were added to SOFA scores or age (8.5 [6.8-24.6], 4.2 [0.9-20.6], respectively). In the elderly (≥65 years), in-hospital mortality rate was significantly higher when both presepsin and IFN-λ3 levels increased than when either one or no biomarker level increased (88.9% vs. 14.3%, p < 0.001). Presepsin and IFN-λ3 predicted disease severity and clinical outcomes in hospitalized COVID-19 patients. Both biomarkers, whether alone or added to the clinical assessment, could be useful for managing COVID-19 patients, especially the elderly.

7.
Ann Lab Med ; 43(5): 425-433, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37080743

RESUMEN

Background: To ensure valid results of big data research in the medical field, the input laboratory results need to be of high quality. We aimed to establish a strategy for evaluating the quality of laboratory results suitable for big data research. Methods: We used Korean Association of External Quality Assessment Service (KEQAS) data to retrospectively review multicenter data. Seven measurands were analyzed using commutable materials: HbA1c, creatinine (Cr), total cholesterol (TC), triglyceride (TG), alpha-fetoprotein (AFP), prostate-specific antigen (PSA), and cardiac troponin I (cTnI). These were classified into three groups based on their standardization or harmonization status. HbA1c, Cr, TC, TG, and AFP were analyzed with respect to peer group values. PSA and cTnI were analyzed in separate peer groups according to the calibrator type and manufacturer, respectively. The acceptance rate and absolute percentage bias at the medical decision level were calculated based on biological variation criteria. Results: The acceptance rate (22.5%-100%) varied greatly among the test items, and the mean percentage biases were 0.6%-5.6%, 1.0%-9.6%, and 1.6%-11.3% for all items that satisfied optimum, desirable, and minimum criteria, respectively. Conclusions: The acceptance rate of participants and their external quality assessment (EQA) results exhibited statistically significant differences according to the quality grade for each criterion. Even when they passed the EQA standards, the test results did not guarantee the quality requirements for big data. We suggest that the KEQAS classification can serve as a guide for building big data.


Asunto(s)
Antígeno Prostático Específico , alfa-Fetoproteínas , Masculino , Humanos , Garantía de la Calidad de Atención de Salud , Hemoglobina Glucada , Macrodatos , Estudios Retrospectivos , Troponina I , Creatinina
8.
Ann Lab Med ; 43(1): 19-28, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36045053

RESUMEN

Background: Mass spectrometry methods exhibit higher accuracy and lower variability than immunoassays at low testosterone concentrations. We developed and validated an ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) assay for quantifying serum total testosterone. Methods: We used an ExionLC UPLC (Sciex, Framingham, MA, USA) system and a Sciex Triple Quad 6500+ (Sciex) MS/MS system in electrospray ionization and positive ion modes with multiple reaction monitoring transitions to evaluate precision, accuracy, linearity, lower limit of quantitation (LLOQ), carryover, ion suppression, stability, and reference intervals. For method comparison, we measured serum testosterone concentrations using this method in 40 subjects whose testosterone concentrations ranged from 0.14 to 55.48 nmol/L as determined using the Architect i2000 immunoassay (Abbott Diagnostics, Abbott Park, IL, USA) and in an additional 160 sera with testosterone concentrations <1.67 nmol/L. Results: The intra- and inter-run precision CVs were <2.81%, and the accuracy bias values were <3.85%, which were all acceptable. The verified linear interval was 0.03-180.84 nmol/L; the LLOQ was 0.03 nmol/L. No significant carryover and ion suppression were observed. The testosterone in serum was stable at 4°C, at -20°C, and after three freeze-thaw cycles. The reference intervals were successfully verified. The correlation was good at testosterone concentrations of 0.14-55.48 nmol/L; however, the Architect assay showed positive percent bias at concentrations <1.67 nmol/L. Conclusions: The UPLC-MS/MS assay shows acceptable performance, with a lower LLOQ than the immunoassay. This method will enable the quantitation of low testosterone concentrations.


Asunto(s)
Espectrometría de Masas en Tándem , Testosterona , Cromatografía Liquida/métodos , Humanos , Inmunoensayo/métodos , Valores de Referencia , Reproducibilidad de los Resultados
11.
Ann Lab Med ; 43(3): 290-294, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36544341

RESUMEN

While numerous studies have evaluated humoral responses to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccines, data on the cellular responses to these vaccines remain sparse. We evaluated T cell responses to ChAdOx1-nCoV-19 and BNT162b2 vaccinations using an interferon gamma (IFN-γ) release assay (IGRA). ChAdOx1-nCoV-19- and BNT162b2-vaccinated participants initially showed stronger T cell responses than unvaccinated controls. The T cell response decreased over time and increased substantially after the administration of a BNT162b2 booster dose. Changes in the T cell response were less significant than those in the anti-receptor-binding domain IgG antibody titer. The study results can serve as baseline data for T cell responses after SARS-CoV-2 vaccination and suggest that the IGRA can be useful in monitoring immunogenicity.


Asunto(s)
COVID-19 , ChAdOx1 nCoV-19 , Humanos , Vacuna BNT162 , Vacunas contra la COVID-19 , COVID-19/prevención & control , SARS-CoV-2 , Vacunación , Anticuerpos Antivirales
12.
Diagnostics (Basel) ; 12(8)2022 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-36010280

RESUMEN

The newly developed Axis-Shield clinical chemistry heparin-binding protein (HBP) assay (Axis-Shield Diagnostics Ltd., Dundee, Scotland) can be applied to fully automated platforms. We aimed to establish a reference interval (RI) of HBP using the Axis-Shield HBP assay, and to evaluate the analytical performance of this assay. An RI was established in 212 sodium citrated plasma samples using the non-parametric method (2.5th and 97.5th percentiles). Precision, linearity, and carry-over were evaluated according to the Clinical and Laboratory Standards Institute guidelines. The RI of HBP was between 5.3 ng/mL and 171.0 ng/mL, which could be applied regardless of gender and age. Percentage coefficients of variations (%CVs) of repeatability and within-laboratory precision were 4.9% and 6.3%, respectively, for low-concentration control and 1.6% and 3.0%, respectively, for high-concentration control. The linearity was excellent (coefficient of determination (R2) = 0.99), and the carry-over rate was negligible (0.05%). This is the first study to establish an RI of HBP using the newly developed and fully automated Axis-Shield HBP assay. The Axis-Shield HBP assay showed an acceptable level of analytical performance and could be used to measure HBP concentrations effectively in routine clinical practice. Further studies are awaited to evaluate the clinical utility of HBP using this automated assay.

13.
J Clin Med ; 11(15)2022 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-35893414

RESUMEN

The Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation is the most commonly used equation for estimated glomerular filtration rate (eGFR). Recently, the European Kidney Function Consortium (EKFC) announced a full-age spectrum equation, and the CKD-EPI announced the CKD-EPI refit equations (CKD-EPI-R). We compared CKD-EPI, EKFC, and CKD-EPI-R equations in a large-scale Korean population and investigated their potential implications for CKD prevalence. In a total of 106,021 individuals who received annual check-ups from 2018 to 2020, we compared the eGFR equations according to the Clinical and Laboratory Standards Institute guidelines. Weighted kappa (κ) agreement was used to compare the potential implications for CKD prevalence across the equations. The median value of eGFR tended to increase in the order of EKFC, CKD-EPI, and CKD-EPI-R equations (92.4 mL/min/1.73 m2, 96.0 mL/min/1.73 m2, and 100.0 mL/min/1.73 m2, respectively). The EKFC and CKD-EPI-R equations showed a very high correlation of eGFR and good agreement for CKD prevalence with CKD-EPI equation (r = 0.98 and 1.00; κ = 0.80 and 0.82, respectively). Compared with the CKD-EPI equation, the EFKC equation overestimated CKD prevalence (3.5%), and the CKD-EPI-R equation underestimated it (1.5%). This is the first study comparing CKD-EPI, EKFC, and CKD-EPI-R equations simultaneously. The EKFC and CKD-EPI-R equations were statistically interchangeable with CKD-EPI equations in this large-scale Korean population. The transition of eGFR equations, however, would lead to sizable changes in the CKD prevalence. To improve kidney health, in-depth discussion considering various clinical aspects is imperative for the transition of eGFR equations.

14.
Front Genet ; 13: 836970, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35664336

RESUMEN

Background: Statins are the most popular agents for the primary and secondary prevention of cardiovascular disease; however, the pharmacokinetic parameters and associated genetic factors in the Korean population have not been fully elucidated. This study explored the pharmacokinetic properties of atorvastatin and the association between genetic variations and atorvastatin pharmacokinetics in healthy Korean subjects. Methods: Atorvastatin (80 mg) was administered to 35 healthy Korean volunteers. Plasma levels of atorvastatin and its metabolites were measured sequentially using liquid chromatography-tandem mass spectrometry from 0 to 24 h after atorvastatin administration. Customized next-generation sequencing analysis was performed covering all coding exons of 15 genes, as well as 46 single-nucleotide variants in 29 genes related to statin pharmacokinetics. Results: The mean area under the concentration-time (AUC) and Cmax (maximum peak concentration) were 269.0 ng/ml∙h and 84.3 ng/ml, respectively, which were approximately two times higher than those reported in Caucasians. Genetic analysis revealed that eight genetic variants in ABCB1, ABCG2, APOA5, CETP, and CYP7A1 contributed to the AUC of atorvastatin. The atorvastatin AUC0-24 h prediction model was developed based on age and eight genetic variants using multivariate linear regression (adjusted R 2 = 0.878, p < 0.0001). Conclusion: This study shows that the pharmacokinetic properties of atorvastatin in Koreans are different from those in Caucasians and that atorvastatin AUC0-24 h could be predicted based on age and eight genetic variants of ABCB1, ABCG2, APOA5, CETP, and CYP7A1.

15.
Ann Lab Med ; 42(6): 630-637, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-35765871

RESUMEN

Background: The top-down (TD) approach using internal quality control (IQC) data is regarded a practical method for estimating measurement uncertainty (MU) in clinical laboratories. We estimated the MU of 14 clinical chemistry analytes using the TD approach and evaluated the effect of lot changes on the MU. Methods: MU values were estimated using subgrouping by reagent lot changes or using the data as a whole, and both methods were compared. Reagent lot change was simulated using randomly generated data, and the mean values and MU for two IQC datasets (different QC material lots) were compared using statistical methods. Results: All MU values calculated using subgrouping were lower than the total values; however, the average differences were minimal. The simulation showed that the greater the increase in the extent of the average shift, the larger the difference in MU. In IQC data comparison, the mean values and MU exhibited statistically significant differences for most analytes. The MU calculation methods gave rise to minimal differences, suggesting that IQC data in clinical laboratories show no significant shift. However, the simulation results demonstrated that notable differences in the MU can arise from significant variations in IQC results before and after a reagent lot change. Additionally, IQC material lots should be treated separately when IQC data are collected for MU estimation. Conclusions: Lot changes in IQC data are a key factor affecting MU estimation and should not be overlooked during MU estimation.


Asunto(s)
Química Clínica , Servicios de Laboratorio Clínico , Humanos , Laboratorios Clínicos , Control de Calidad , Incertidumbre
16.
Ann Lab Med ; 42(6): 621-629, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-35765870

RESUMEN

Background: Anti-Müllerian hormone (AMH) is one of the most reliable markers of ovarian reserve. Automated AMH assays are widely used in clinical laboratories, but reference intervals for the Elecsys AMH assay for Asian populations have not yet been determined. We aimed to determine reference intervals in healthy Korean women. Methods: The study included 1,450 women aged 19 to 54 years who participated in the Korea National Health and Nutrition Examination Survey between 2013 and 2016. The study participants were divided into seven 5-year age groups. AMH and progesterone concentrations were measured using Roche Elecsys assays, and bone morphogenetic protein-15 (BMP15) was genotyped for the detection of major variants. Age group-specific reference intervals for AMH were established as recommended by the CLSI EP28-A3c guidelines. Results: The mean age was 37.4 years. AMH concentrations decreased with increasing age, especially after 40 years, with the median AMH decreasing from 30.9 pmol/L in participants of 19-24 years to 0.071 pmol/L in participants of 50-54 years. The mid-95 percentile AMH reference intervals decreased from 7.93-81.21 pmol/L in participants of 19-24 years to 0.07-3.86 pmol/L in participants of 50-54 years. Disease-associated BMP15 variants were not detected. Conclusions: We determined Elecsys AMH assay reference intervals in healthy Korean women. The results may provide basic information for the interpretation of AMH concentrations and assessment of ovarian reserve in Korean women.


Asunto(s)
Hormona Antimülleriana , Reserva Ovárica , Adulto , Pueblo Asiatico/genética , Femenino , Humanos , Encuestas Nutricionales , Valores de Referencia
17.
Vox Sang ; 117(3): 399-407, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34318939

RESUMEN

BACKGROUND AND OBJECTIVES: VISION Max (Ortho Clinical Diagnostics, Raritan, NJ) measures anti-A/B isoagglutinin titres using automated column agglutination technology (CAT). We compared tube test (TT) and CAT of VISION Max comprehensively, including failure mode and effect analysis (FMEA), turnaround time (TAT) and cost, and suggested modified CAT (MCAT). MATERIALS AND METHODS: For 100 samples (each 25 for blood type A, B and O with anti-A and anti-B), anti-A/B isoagglutinin titres were measured by TT and CAT (1:2-1:1024 dilution), as well as by MCAT (with agglutination at 1:32 dilution, then perform additional testing from 1:64 to 1:1024). We assessed the agreement and correlation between TT and CAT and compared FMEA (risk priority number [RPN] score), TAT (h:min:sec) and cost (US dollar, US $) among TT, CAT and MCAT. RESULTS: TT and CAT showed overall substantial agreement (k = 0.73) and high correlation (ρ ≥ 0.75) except blood type O with anti-A (ρ = 0.68). Compared with TT, CAT showed lower RPN scores in FMEA and similar TAT and cost (FMEA, 33,700 vs. 184,300; TAT, 15:23:00 vs. 14:26:40; cost, 1377.4 vs. 1312.4, respectively). Regarding FMEA, TAT and cost, MCAT was superior to CAT or TT (43,810; 13:28:00; 899.2, respectively). CONCLUSION: This is the first multidimensional analysis on VISION Max CAT for measuring anti-A/B isoagglutinin titres. The results of anti-A/B isoagglutinin titres by CAT were comparable with those of TT. MCAT would be a safe, time-saving and cost-effective alternative to TT and CAT in high-volume blood bank laboratories.


Asunto(s)
Sistema del Grupo Sanguíneo ABO , Hemaglutininas , Aglutinación , Anticuerpos , Tecnología
18.
Ann Lab Med ; 42(1): 63-70, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34374350

RESUMEN

BACKGROUND: Recently, two fully automated immunoassays for antinuclear antibody (ANA) screening were introduced: EliA CTD Screen (Thermo Fisher Scientific, Freiburg, Germany) and QUANTA Flash CTD Screen Plus (Inova Diagnostics, San Diego, USA). We evaluated their clinical performance in comparison with the indirect immunofluorescence assay (IIFA) and analyzed samples with discrepant results. METHODS: In total, 406 serum samples (206 from patients undergoing routine checkups and 200 from rheumatology clinic patients) were assayed using EliA, QUANTA Flash, and IIFA. We evaluated assay concordance and agreement and confirmed the presence of anti-extractable nuclear antigen (ENA) antibodies in samples with discrepant automated immunoassay and IIFA results. Additionally, we compared the clinical performance of each assay in diagnosing ANA-associated rheumatic disease (AARD) and adjusted the cut-off values. RESULTS: In rheumatology clinic samples, the concordance and agreement were 91.5% and strong between EliA and QUANTA Flash, 79.0% and weak between EliA and IIFA, and 80.5% and moderate between QUANTA Flash and IIFA, respectively. In automated immunoassay-positive, IIFA-negative samples (N=15), all anti-ENA antibodies detected (6/15) were anti-Sjögren's syndrome antigen A/Ro (Ro60) antibodies. The automated immunoassays and IIFA showed high accuracy for diagnosing AARD, and adjusted cut-off values improved their sensitivities (EliA with 0.56 ratio, 82.9% sensitivity; QUANTA Flash with 9.7 chemiluminescent units, 87.8% sensitivity). CONCLUSIONS: The two automated immunoassays showed reliable performance compared with IIFA and can be efficiently used with the IIFA in clinical immunology laboratories. Clinical cut-off values can be adjusted according to the workflow in each laboratory.


Asunto(s)
Anticuerpos Antinucleares , Tamizaje Masivo , Técnica del Anticuerpo Fluorescente Indirecta , Humanos , Inmunoensayo , Sensibilidad y Especificidad
19.
Microbiol Spectr ; 9(3): e0120221, 2021 12 22.
Artículo en Inglés | MEDLINE | ID: mdl-34817223

RESUMEN

Multiple vaccines against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have been developed and administered to mitigate the coronavirus disease 2019 (COVID-19) pandemic. We assessed the humoral response of BNT162b2 and ChAdOx1 nCoV-19 using Siemens SARS-CoV-2 IgG (sCOVG; cutoff of ≥1.0 U/ml), Abbott SARS-CoV-2 IgG II Quant (CoV-2 IgG II; cutoff of ≥50.0 AU/ml), and GenScript cPASS SARS-CoV-2 neutralization antibody detection kits (cPASS; cutoff of ≥30% inhibition). We collected 710 serum samples (174 samples after BNT162b2 and 536 samples after ChAdOx1 nCoV-19). Venous blood was obtained 3 weeks after first and second vaccinations. In both vaccines, sCOVG, CoV-2 IgG II, and cPASS showed a high seropositive rate (>95.7%) except for cPASS after the first vaccination with ChAdOx1 nCoV-19 (68.8%). Using sCOVG and CoV-2 IgG II, the ratios of antibody value (second/first) increased 10.6- and 11.4-fold in BNT162b2 (first 14.1, second 134.8 U/ml; first 1,416.2, second 14,326.4 AU/ml) and 2.3- and 2.0-fold in ChAdOx1 nCoV-19 (first 4.0, second 9.1 U/ml; first 431.0, second 9,744.0 AU/ml). cPASS-positive results indicated a very high concordance rate with sCOVG and CoV-2 IgG II (>98%), whereas cPASS-negative results showed a relatively low concordance rate (range of 22.2% to 66.7%). To predict cPASS positivity, we suggested additional cutoffs for sCOVG and CoV-2 IgG II at 2.42 U/ml and 284 AU/ml, respectively. In conclusion, BNT162b2 and ChAdOx1 nCoV-19 evoked robust humoral responses. sCOVG and CoV-2 IgG II showed a very strong correlation with cPASS. sCOVG and CoV-2 IgG II may predict the presence of neutralizing antibodies against SARS-CoV-2. IMPORTANCE The Siemens severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) IgG (sCOVG; Siemens Healthcare Diagnostics Inc., NY, USA) and Abbott SARS-CoV-2 IgG II Quant (CoV-2 IgG II; Abbott Laboratories, Sligo, Ireland), which are automated, quantitative SARS-CoV-2-binding antibody assays, have been recently launched. This study aimed to evaluate the humoral immune response of BNT162b2 and ChAdOx1 nCoV-19 vaccines using sCOVG and CoV-2 IgG II and compare the quantitative values with the results of the GenScript surrogate virus neutralization test (cPASS; GenScript, USA Inc., NJ, USA). Our findings demonstrated that both BNT162b2 and ChAdOx1 nCoV-19 elicited a robust humoral response after the first vaccination and further increased after the second vaccination. sCOVG and CoV-2 IgG II showed a strong correlation, and the concordance rates among sCOVG, CoV-2 IgG II, and cPASS were very high in the cPASS-positive results. The additional cutoff sCOVG and CoV-2 IgG II could predict the results of cPASS.


Asunto(s)
Anticuerpos Neutralizantes/sangre , Anticuerpos Antivirales/sangre , Vacunas contra la COVID-19/inmunología , COVID-19/inmunología , Inmunidad Humoral , Vacunación , Adulto , Vacuna BNT162/inmunología , COVID-19/prevención & control , ChAdOx1 nCoV-19/inmunología , Femenino , Humanos , Inmunoglobulina G/sangre , Masculino , Persona de Mediana Edad , SARS-CoV-2 , Pruebas Serológicas/métodos , Glicoproteína de la Espiga del Coronavirus/inmunología , Adulto Joven
20.
Ann Lab Med ; 41(4): 372-379, 2021 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-33536355

RESUMEN

BACKGROUND: Accurate serum creatinine (Cr) concentration measurement is essential for evaluating kidney function. In 2011, the Korean Association of External Quality Assessment Service (KEQAS) launched an accuracy-based Cr proficiency testing (ABCr PT) survey. We analyzed long-term data of the KEQAS ABCr PT survey collected between 2011 and 2019 to assess recent trends in Cr assays in Korea. METHODS: The ABCr PT survey including three commutable fresh-frozen serum samples was performed twice a year. The target Cr concentration was assigned using isotope-dilution mass spectrometry. We analyzed data obtained from the participating laboratories, calculated the yearly bias, and evaluated bias trends for the major reagents and instruments. Outliers were excluded from all analysis. RESULTS: The mean percentage bias based on the total data of all participating laboratories was 10.8% in the 2011-A survey and 0.2% in 2019-B survey. Bias for the major reagents and instruments differed depending on the manufacturer. Enzymatic assays generally showed desirable bias ranging from -3.9% to 3.2% at all Cr concentrations and lower interlaboratory variability than non-enzymatic assays (enzymatic vs. non-enzymatic, 3.3%-7.2% vs. 6.3%-9.1%). CONCLUSIONS: Although the mean percentage bias of Cr assays tends to decrease over time, it is necessary to continuously strive to improve Cr assay accuracy, especially at low concentrations.


Asunto(s)
Ensayos de Aptitud de Laboratorios , Creatinina , Humanos , Laboratorios , Espectrometría de Masas , República de Corea
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...