Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 12(1): 14909, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36050347

RESUMEN

COVID-19 antibody testing has been developed to investigate humoral immune response in SARS-CoV-2 infection. To assess the serological dynamics and neutralizing potency following SARS-CoV-2 infection, we investigated the neutralizing (NT) antibody, anti-spike, and anti-nucleocapsid antibodies responses using a total of 168 samples obtained from 68 SARS-CoV-2 infected patients. Antibodies were measured using an authentic virus neutralization assay, the high-throughput laboratory measurements of the Abbott Alinity quantitative anti-spike receptor-binding domain IgG (S-IgG), semiquantitative anti-spike IgM (S-IgM), and anti-nucleocapsid IgG (N-IgG) assays. The quantitative measurement of S-IgG antibodies was well correlated with the neutralizing activity detected by the neutralization assay (r = 0.8943, p < 0.0001). However, the kinetics of the SARS-CoV-2 NT antibody in severe cases were slower than that of anti-S and anti-N specific antibodies. These findings indicate a limitation of using the S-IgG antibody titer, detected by the chemiluminescent immunoassay, as a direct quantitative marker of neutralizing activity capacity. Antibody testing should be carefully interpreted when utilized as a marker for serological responses to facilitate diagnostic, therapeutic, and prophylactic interventions.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anticuerpos Neutralizantes , Anticuerpos Antivirales , Prueba de COVID-19 , Humanos , Inmunoglobulina G , Inmunoglobulina M , Sensibilidad y Especificidad
2.
Heliyon ; 7(11): e08393, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34805572

RESUMEN

BACKGROUND: We evaluated the efficacy of the Siemens SARS-CoV-2 Total Antibody assay (CV2T) and IgG assay (CV2G) that can detect antibodies against the receptor binding domain of S antigen in patients with COVID-19 in a Tokyo metropolitan area. METHODS: Sensitivity and antibody levels were examined by CV2T and CV2G on Dimension EXL 200 using 236 serum samples obtained from 79 RT-PCR confirmed COVID-19 patients at multiple time points and were compared with disease severity by the World Health Organization criteria. The assay specificity was evaluated using samples collected before the COVID-19 pandemic. RESULTS: The sensitivity of CV2T and CV2G were low (16.7-21.4%) in days 0-6 and increased to 43.8-52.5% in days 7-13 and to 80.8-90.0% in days 14-20. The seroprevalences persisted after day 21 to days past 42 regardless of disease severity. In every day grouping, mean antibody levels were higher in severe cases than in mild cases with a significant difference in days 14-20 and days 20-27. The specificity was 97.9 % (95% CI; 92.8-99.8) for CV2T and 99.0 % (95% CI; 94.6-100) for CV2G. CONCLUSIONS: Our results indicate a high specificity and high sensitivity at 14 days of CV2T and CV2G as antibody detection assays.

3.
PLoS One ; 14(3): e0207170, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30835732

RESUMEN

Tyrosine kinase inhibitors (TKIs) targeting the BCR-ABL1 fusion protein, encoded by the Philadelphia chromosome, have drastically improved the outcomes for patients with chronic myeloid leukemia (CML). Although several real-time quantitative polymerase chain reaction (RQ-PCR) kits for the detection of BCR-ABL1 transcripts are commercially available, their accuracy and efficiency in laboratory practice require reevaluation. We have developed a new in-house RQ-PCR method to detect minimal residual disease (MRD) in CML cases. MRD was analyzed in 102 patients with CML from the DOMEST study, a clinical trial to study the rationale for imatinib mesylate discontinuation in Japan. The BCR-ABL1/ABL1 ratio was evaluated using the international standard (IS) ratio, where IS < 0.1% was defined as a major molecular response. At enrollment, BCR-ABL1 transcripts were undetectable in all samples using a widely-applied RQ-PCR method performed in the commercial laboratory, BML (BML Inc., Tokyo, Japan); however, the in-house method detected the BCR-ABL1 transcripts in five samples (5%) (mean IS ratio: 0.0062 ± 0.0010%). After discontinuation of imatinib, BCR-ABL1 transcripts were detected using the in-house RQ-PCR in 21 patients (21%) that were not positive using the BML method. Nineteen samples were also tested using a commercially available RQ-PCR assay kit with a detection limit of IS ratio, 0.0032 (ODK-1201, Otsuka Pharmaceutical Co., Tokyo, Japan). This method detected low levels of BCR-ABL1 transcripts in 14 samples (74%), but scored negative for five samples (26%) that were positive using the in-house method. From the perspective of the in-house RQ-PCR method, number of patients confirmed loss of MMR was 4. These data suggest that our new in-house RQ-PCR method is effective for monitoring MRD in CML.


Asunto(s)
Proteínas de Fusión bcr-abl/genética , Mesilato de Imatinib/uso terapéutico , Leucemia Mielógena Crónica BCR-ABL Positiva/tratamiento farmacológico , Monitoreo Fisiológico/métodos , Neoplasia Residual/diagnóstico , Inhibidores de Proteínas Quinasas/uso terapéutico , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Humanos , Leucemia Mielógena Crónica BCR-ABL Positiva/genética , Leucemia Mielógena Crónica BCR-ABL Positiva/patología , Persona de Mediana Edad , Neoplasia Residual/epidemiología , Neoplasia Residual/genética , Privación de Tratamiento , Adulto Joven
4.
PLoS One ; 13(10): e0202429, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30281597

RESUMEN

The detection and quantification of leukemia-associated fusion gene transcripts play important roles in the diagnosis and follow-up of leukemias. To establish a standardized method without interlaboratory discrepancies, we developed a novel one-step reverse transcription quantitative PCR (RT-qPCR) assay, called "the Eprobe leukemia assay," for major and minor BCR-ABL1, RUNX1-RUNX1T1, and various isoforms of PML-RARA. This assay is comprised of Eprobes that are exciton-controlled hybridization-sensitive fluorescent oligonucleotides. Melting curve analyses were performed on synthetic quantitative standard RNAs with strict quality control. Quantification capacity was evaluated by comparison with TaqMan RT-qPCR using 67 primary leukemia patient samples. The lower limit of detection and the limit of quantification of this assay were less than 31.3 copies/reaction and 62.5 copies/reaction, respectively. This assay correctly detected the fusion genes in samples with 100% sensitivity and specificity. The specificity of the reactions was confirmed by melting curve analyses. The assay detected low-level expression of minor BCR-ABL1 co-expressed with major BCR-ABL1. These results illustrate the feasibility and high accuracy of the Eprobe leukemia assay, even for minimal residual disease monitoring.


Asunto(s)
Proteínas de Fusión bcr-abl/genética , Leucemia/diagnóstico , Leucemia/genética , Proteínas de Fusión Oncogénica/genética , Subunidad alfa 2 del Factor de Unión al Sitio Principal/genética , Femenino , Regulación Neoplásica de la Expresión Génica , Células HL-60 , Humanos , Leucemia/patología , Masculino , Proteínas de Fusión Oncogénica/aislamiento & purificación , Reacción en Cadena de la Polimerasa , ARN/química , ARN/genética , Proteína 1 Compañera de Translocación de RUNX1/genética , Temperatura de Transición
5.
Clin Lab ; 63(5): 1021-1026, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28627833

RESUMEN

BACKGROUND: EGFR, a tyrosine-kinase, plays an important role in the progression of lung cancer. Since genetic abnormality of EGFR alters the effects of tyrosine-kinase inhibitors targeting EGFR, molecular analyses of EGFR have recently gained more attention in the treatment of lung cancer. However, several different techniques are available and which method is superior has not been determined. In this study, we compared two recently developed PCR-based techniques, PCR-clamp method and cobas EGFR assay. METHODS: Ninety-four surgical samples and 58 biopsy samples from patients suffering from non-small cell lung cancers (NSCLCs) were included in the study. Samples with positive and negative genetic abnormalities, 66 and 28 respectively, were chosen for PCR-Clamp methods. Those same samples were reanalyzed with cobas EGFR assay. RESULTS: The concordance between PCR-Clamp and cobas EGFR methods was 95.7%. PCR-Clamp failed to detect four mutations that were detected with cobas EGFR assay. These two methods were further tested by analyzing 58 random biopsy samples. The concordance for the biopsy samples was 93.1%, and PCR-Clamp, again, failed to detect three mutations that were detected with cobas EGFR assay. CONCLUSIONS: Our results showed both methods detected most of the known EGFR mutations and the concordance was similar to those previously reported in different ethnicities. However, in our study, PCR-Clamp method failed to detect a total of seven mutations that were detected with cobas EGFR assay. Thus, we concluded that cobas EGFR assay is an easier and more accurate screening assay than PCR-Clamp method in detecting EGFR genetic abnormalities.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/genética , Receptores ErbB/genética , Neoplasias Pulmonares/genética , Reacción en Cadena de la Polimerasa , Humanos , Mutación , Juego de Reactivos para Diagnóstico
6.
Int J Hematol ; 103(6): 665-72, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26984594

RESUMEN

Clinical demand for the prompt assessment of the activity of direct-acting factor Xa inhibitors in the emergency care setting is increasing. In the present study, we examined whether prothrombin time (PT) tests can serve as a clinically useful indicator of anti-factor Xa activity. In the first series, the in vitro effect of edoxaban on PT was evaluated by spiking human plasma with edoxaban and measuring PT using three different commercial PT tests. In the second series, the reversal effect of prothrombin complex concentrates (PCC) and activated PCC (aPCC) in edoxaban-spiked plasma was evaluated. In the third series, PT of plasma samples from patients administered either 15 or 30 mg/day of edoxaban was assessed, and the results were compared with edoxaban concentrations determined by a calibrated anti-factor Xa activity assay. The spike test revealed that all PT reagents positively correlated with edoxaban. The sensitivity to edoxaban varied among the three reagents and Triniclot(®) Excel S showed the best performance. Prolonged PT by edoxaban was reversed by PCC and aPCC in a dose-dependent manner; however, complete reversal was not achieved. Positive correlation between anti-factor Xa activity and PT was shown in the clinical samples at the edoxaban range from 0 to >300 ng/mL.


Asunto(s)
Tiempo de Protrombina , Piridinas/sangre , Tiazoles/sangre , Factores de Coagulación Sanguínea/farmacología , Relación Dosis-Respuesta a Droga , Monitoreo de Drogas/métodos , Inhibidores del Factor Xa/farmacología , Inhibidores del Factor Xa/uso terapéutico , Humanos , Piridinas/farmacología , Tiazoles/farmacología
7.
Clin Appl Thromb Hemost ; 22(5): 453-8, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26177660

RESUMEN

Fondaparinux (FPX), a synthesized factor Xa inhibitor, is one of the most popular anticoagulants for the prevention of postoperative venous thromboembolism (VTE). Although routine monitoring is not required, the bleeding adverse events cannot be neglected, and the measurement of anti-Xa activity is expected to be monitored. The primary purpose of this study is to evaluate the performances of 2 chromogenic assays for the detection of anti-Xa activity. Furthermore, the pharmacokinetics of FPX was examined using chromogenic assays. Anti-Xa activity was measured using 2 FPX-based chromogenic substrates (S2222 and STA-Liquid Anti-Xa). The reproducibility, detection limits, linearity, and correlations between the substrates were examined using normal plasma doped with low and high concentrations of FPX formulation. In addition, anti-Xa activity in 235 clinical samples from 164 cases treated was measured, and the pharmacokinetics of FPX was evaluated. Both of the tested substrates were capable of accurately measuring the anti-Xa activity of FPX, with a lower limit of 0.05 µg/mL and a coefficient of variation of less than 10%. The repeated administration of FPX induced a gradual but significant increase in the anti-Xa activity, which was negatively correlated with body weight and estimated glomerular filtration rate. No significant correlation between the anti-Xa activity and the occurrence of postoperative VTE or bleeding event was observed. Anti-Xa activity can be successfully determined using 2 chromogenic assays and automated biochemical analyzers. The clinical significance of anti-Xa activity monitoring should be examined in the future study.


Asunto(s)
Compuestos Cromogénicos , Pruebas de Química Clínica/normas , Polisacáridos/farmacocinética , Adulto , Anciano , Anciano de 80 o más Años , Anticoagulantes/farmacocinética , Peso Corporal , Pruebas de Química Clínica/métodos , Relación Dosis-Respuesta a Droga , Inhibidores del Factor Xa/farmacocinética , Femenino , Fondaparinux , Tasa de Filtración Glomerular , Hemorragia/etiología , Hemorragia/prevención & control , Humanos , Masculino , Persona de Mediana Edad , Polisacáridos/administración & dosificación , Complicaciones Posoperatorias/prevención & control , Tromboembolia Venosa/prevención & control
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA