Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Eur Radiol ; 23(3): 623-31, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22940731

RESUMEN

OBJECTIVE: To survey procedures and protocols in paediatric computed tomography (CT) in 40 less resourced countries. METHODS: Under a project of the International Atomic Energy Agency, 146 CT facilities in 40 countries of Africa, Asia, Europe and Latin America responded to an electronic survey of CT technology, exposure parameters, CT protocols and doses. RESULTS: Modern MDCT systems are available in 77 % of the facilities surveyed with dedicated paediatric CT protocols available in 94 %. However, protocols for some age groups were unavailable in around 50 % of the facilities surveyed. Indication-based protocols were used in 57 % of facilities. Estimates of radiation dose using CTDI or DLP from standard CT protocols demonstrated wide variation up to a factor of 100. CTDI(vol) values for the head and chest were between two and five times those for an adult at some sites. Sedation and use of shielding were frequently reported; immobilisation was not. Records of exposure factors were kept at 49 % of sites. CONCLUSION: There is significant potential for improvement in CT practice and protocol use for children in less resourced countries. Dose estimates for young children varied widely. This survey provides critical baseline data for ongoing quality improvement efforts by the IAEA.


Asunto(s)
Accesibilidad a los Servicios de Salud/estadística & datos numéricos , Pediatría/estadística & datos numéricos , Pautas de la Práctica en Medicina/estadística & datos numéricos , Protección Radiológica/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , África/epidemiología , Asia/epidemiología , Europa (Continente)/epidemiología , Encuestas de Atención de la Salud , Humanos , América Latina/epidemiología , Dosis de Radiación
2.
Eur J Radiol ; 81(10): e982-9, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22835877

RESUMEN

Recognizing the lack of information on image quality and patient doses in most countries in Asia, the International Atomic Energy Agency (IAEA) initiated a project to assess the status of imaging technology, practice in conventional radiography, mammography, computed tomography (CT) and interventional procedures, and to implement optimisation actions. A total of 20 countries participated. Obsolete practices of use of fluoroscopy for positioning, photofluorography, chest fluoroscopy and conventional tomography were reported by 4 out of 7 countries that provided this information. Low-kV technique for chest radiography is in use in participating countries for 20-85% of cases, and manual processing is in 5-85% of facilities in 5 countries. Instances of the use of adult CT protocol for children in three participating countries were observed in 10-40% of hospitals surveyed. After implementation of a Quality Control programme, the image quality in conventional radiography improved by zero to 13 percentage points in certain countries and dose reduction was from 10% to 85%. In mammography, poor quality, ranging from 10 to 29% of images in different countries was observed. The project increased attention to dose quantities and dose levels in computed tomography, although doses in most cases were not higher than reference levels. In this study 16-19% of patients in interventional cardiology received doses that have potential for either stochastic risk or tissue reaction. This multi-national study is the first of its kind in the Asia, and it provided insight into the situation and opportunities for improvement.


Asunto(s)
Carga Corporal (Radioterapia) , Diagnóstico por Imagen/estadística & datos numéricos , Pautas de la Práctica en Medicina/estadística & datos numéricos , Traumatismos por Radiación/epidemiología , Traumatismos por Radiación/prevención & control , Monitoreo de Radiación/estadística & datos numéricos , Protección Radiológica/estadística & datos numéricos , Adulto , Asia/epidemiología , Niño , Recolección de Datos , Humanos , Vigilancia de la Población
3.
AJR Am J Roentgenol ; 198(5): 1021-31, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22528891

RESUMEN

OBJECTIVE: The purpose of this study was to assess the frequency of pediatric CT in 40 less-resourced countries and to determine the level of appropriateness in CT use. MATERIALS AND METHODS: Data on the increase in the number of CT examinations during 2007 and 2009 and appropriate use of CT examinations were collected, using standard forms, from 146 CT facilities at 126 hospitals. RESULTS: The lowest frequency of pediatric CT examinations in 2009 was in European facilities (4.3%), and frequencies in Asia (12.2%) and Africa (7.8%) were twice as high. Head CT is the most common CT examination in children, amounting to nearly 75% of all pediatric CT examinations. Although regulations in many countries assign radiologists with the main responsibility of deciding whether a radiologic examination should be performed, in fact, radiologists alone were responsible for only 6.3% of situations. Written referral guidelines for imaging were not available in almost one half of the CT facilities. Appropriateness criteria for CT examinations in children did not always follow guidelines set by agencies, in particular, for patients with accidental head trauma, infants with congenital torticollis, children with possible ventriculoperitoneal shunt malfunction, and young children (< 5 years old) with acute sinusitis. In about one third of situations, nonavailability of previous images and records on previously received patient doses have the potential to lead to unnecessary examinations and radiation doses. CONCLUSION: With increasing use of CT in children and a lack of use of appropriateness criteria, there is a strong need to implement guidelines to avoid unnecessary radiation doses to children.


Asunto(s)
Pautas de la Práctica en Medicina/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , África , Asia , Niño , Preescolar , Europa (Continente) , Humanos , Lactante , Recién Nacido , Agencias Internacionales , América Latina , Dosis de Radiación , Protección Radiológica , Encuestas y Cuestionarios
4.
Eur J Radiol ; 81(9): 2161-8, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21665395

RESUMEN

PURPOSE: The objective is to study mammography practice from an optimisation point of view by assessing the impact of simple and immediately implementable corrective actions on image quality. MATERIALS AND METHODS: This prospective multinational study included 54 mammography units in 17 countries. More than 21,000 mammography images were evaluated using a three-level image quality scoring system. Following initial assessment, appropriate corrective actions were implemented and image quality was re-assessed in 24 units. RESULTS: The fraction of images that were considered acceptable without any remark in the first phase (before the implementation of corrective actions) was 70% and 75% for cranio-caudal and medio-lateral oblique projections, respectively. The main causes for poor image quality before corrective actions were related to film processing, damaged or scratched image receptors, or film-screen combinations that are not spectrally matched, inappropriate radiographic techniques and lack of training. Average glandular dose to a standard breast was 1.5 mGy (mean and range 0.59-3.2 mGy). After optimisation the frequency of poor quality images decreased, but the relative contributions of the various causes remained similar. Image quality improvements following appropriate corrective actions were up to 50 percentage points in some facilities. CONCLUSIONS: Poor image quality is a major source of unnecessary radiation dose to the breast. An increased awareness of good quality mammograms is of particular importance for countries that are moving towards introduction of population-based screening programmes. The study demonstrated how simple and low-cost measures can be a valuable tool in improving of image quality in mammography.


Asunto(s)
Interpretación de Imagen Asistida por Computador/normas , Mamografía/estadística & datos numéricos , Mamografía/normas , Guías de Práctica Clínica como Asunto , Garantía de la Calidad de Atención de Salud/estadística & datos numéricos , Radiometría/estadística & datos numéricos , Radiometría/normas , África , Asia , Europa Oriental , Humanos , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
AJR Am J Roentgenol ; 193(2): 559-69, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19620457

RESUMEN

OBJECTIVE: The purpose of our study was to investigate the level of radiation protection of patients and staff during interventional procedures in 20 countries of Africa, Asia, and Europe. SUBJECTS AND METHODS: In a multinational prospective study, information on radiation protection tools, peak skin dose (PSD), and kerma-area product (KAP) was provided by 55 hospitals in 20 mainly developing countries (nine mostly in Eastern Europe, five in Africa, and six in Asia). RESULTS: Nearly 40% of the interventional rooms had an annual workload of more than 2,000 patients. It is remarkable that the workload of pediatric interventional procedures can reach the levels of adult procedures even in developing countries. About 30% of participating countries have shown a 100% increase in workload in 3 years. Lead aprons are used in all participating rooms. Even though KAP was available in almost half of the facilities, none had experience in its use. One hundred of 505 patients monitored for PSD (20%) were above the 2-Gy threshold for deterministic effects. CONCLUSION: Interventional procedures are increasing in developing countries, not only for adults but also for pediatric patients. The situation with respect to staff protection is considered generally acceptable, but this is not the case for patient protection. Many patients exceeded the dose threshold for erythema. A substantial number (62%) of percutaneous transluminal coronary angioplasty procedures performed in developing countries in this study are above the currently known dose reference level and thus could be optimized. Therefore, this study has significance in introducing the concept of patient dose estimation and dose management.


Asunto(s)
Exposición a Riesgos Ambientales/estadística & datos numéricos , Dosis de Radiación , Monitoreo de Radiación/estadística & datos numéricos , Protección Radiológica/estadística & datos numéricos , Radiografía Intervencional/estadística & datos numéricos , Adulto , África , Contaminantes Radiactivos del Aire/análisis , Asia , Calibración , Niño , Europa (Continente) , Femenino , Humanos , Masculino , Exposición Profesional/análisis , Exposición Profesional/estadística & datos numéricos , Proyectos Piloto , Estudios Prospectivos , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Dispersión de Radiación , Carga de Trabajo/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...