Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 6 de 6
1.
Food Chem Toxicol ; 188: 114632, 2024 Jun.
Article En | MEDLINE | ID: mdl-38583503

PFOA is one of the most representative compounds in the family of perfluorinated organic compounds. Due to its varying toxicity, alternatives to PFOA are beginning to emerge. HFPO-TA is an alternative for PFOA. It is currently unclear whether HFPO-TA affects glucose and lipid metabolism. In this study, rats were used as an animal model to investigate the effects of HFPO-TA on liver glucose and lipid metabolism. We found that HFPO-TA can affect glucose tolerance. Through omics analysis and molecular detection, it was found that HFPO-TA mainly affects the PPAR signaling pathway in the liver of rats, inhibiting liver glycolysis while promoting glucose production. HFPO-TA not only promotes the synthesis of fatty acids in the liver, but also promotes the breakdown of fatty acids, which ultimately leads to the disruption of hepatic glucose and lipid metabolism. The effects of HFPO-TA on metabolism are discussed in this paper to provide a reference for the risk assessment of this PFOA substitute.


Glucose , Lipid Metabolism , Liver , Metabolome , Peroxisome Proliferator-Activated Receptors , Signal Transduction , Transcriptome , Animals , Lipid Metabolism/drug effects , Liver/metabolism , Liver/drug effects , Signal Transduction/drug effects , Rats , Male , Peroxisome Proliferator-Activated Receptors/metabolism , Peroxisome Proliferator-Activated Receptors/genetics , Transcriptome/drug effects , Glucose/metabolism , Metabolome/drug effects , Rats, Sprague-Dawley , Fluorocarbons
2.
Ying Yong Sheng Tai Xue Bao ; 33(4): 1037-1044, 2022 Apr.
Article Zh | MEDLINE | ID: mdl-35543057

In order to optimize water and fertilizer use in the double-cropping rice in eastern Fujian Province, a field runoff plot experiment was conducted to investigate rice yield, nutrient uptake, and runoff losses of N (nitrogen) and P (phosphorus) in the T0(no chemical fertilization with traditional flooding irrigation), T1(common chemical fertilizer of 273 kg N·hm-2, 59 kg P·hm-2, and 112 kg K·hm-2 combined with traditional flooding irrigation), T2(chemical fertilizer of 240 kg N·hm-2, 52 kg P·hm-2, and 198 kg K·hm-2 combined with traditional flooding irrigation) and T3(chemical fertilizer combined with shallow intermittent irrigation) treatments. Results showed that early rice grain yield in the T1, T2 and T3 treatments significantly increased by 0.7, 1.0, 1.1 times, late rice grain yield significantly increased by 0.9, 1.1, 1.0 times compared to that in the T0 treatment, respectively. The T1, T2 and T3 treatments significantly increased the uptake of N and P in aboveground parts of the plants, especially in grains. The T1, T2 and T3 treatments significantly increased N uptake by 1.1, 1.2, 1.2 times, increased P uptake by 0.9, 1.4, 1.6 times in early-season grains, and significantly increased N uptake by 0.8, 1.0, 1.0 times, increased P uptake by 0.7, 0.9, 0.9 times in late-season grains, compared to T0, respectively. Furthermore, T3 increased agronomic N use efficiency (AEN) and agronomic P use efficiency (AEP) by 71.1% and 69.2% in early rice plants, increased AEN and AEP by 26.4% and 25.0% in late rice plants, whereas T3 decreased total dissolved N (DN) by 16.0% in comparison with T1. Dissolved inorganic N loss in surface runoff occurred mainly in the form of NO3--N (nitrate N) under different water and fertilizer regimes. However, there were no significant differences in AEN and AEP between T2 and T3 treatments. These findings suggested that optimal applications of water and fertilizers (T3) might increase N and P uptake in rice plants, maintain yield, and reduce N loss, especially in the form of NO3--N in surface water from early rice field. In general, this study could provide theoretical support for the optimization of irrigation and fertilization and for the control of N and P non-point source pollution from the double cropping rice paddy fields in eastern Fujian Province.


Oryza , Phosphorus , Agriculture/methods , China , Fertilization , Fertilizers , Nitrogen/analysis , Phosphorus/analysis , Soil , Water
3.
Int J Gynecol Cancer ; 27(4): 768-775, 2017 05.
Article En | MEDLINE | ID: mdl-28267131

OBJECTIVE: We present a new technique of 3-dimensional computed tomography-guided interstitial (IS) brachytherapy (BT) for locally advanced cervical cancer, offering a more advantageous clinical treatment approach. MATERIALS/METHODS: Interstitial BT was performed using an applicator combining uterine tandem and metal needles; needles were inserted freehand under real-time 3-dimensional computed tomography guidance. Twenty-eight patients with bulky tumors and/or parametrial extension (tumor size > 5 cm) after external beam radiotherapy received IS BT. Dosimetric outcomes of the IS BT including the total dose (external beam radiotherapy and high dose-rate BT) D90 for the high-risk clinical target volume (HR-CTV) and D2cc for the organs at risk (OARs) were investigated and compared with a former patient group consisting of 30 individuals who received the conventional intracavitary (IC) BT. RESULTS: The mean D90 values for HR-CTV in the IC BT and IS BT groups were 76.9 ± 5.7 and 88.1 ± 3.3 Gy, respectively. Moreover, 85.7% of the patients received D90 for HR-CTV of 87 Gy or greater in the IS BT group, and only 6.7% of the patients received D90 for HR-CTV of 87 Gy or greater in the IC BT group. The D2cc for the bladder, rectum, and sigmoid were 84.7 ± 6.8, 69.2 ± 4.2, and 67.8 ± 4.5 Gy in the IC BT group and 81.8 ± 6.5, 66.8 ± 4.0, and 64.8 ± 4.1 Gy in the IS BT group. The mean number of needles was 6.9 ± 1.4, with a mean depth of 2.9 ± 0.9 mm for each IS BT. Interstitial BT was associated with only minor complications. CONCLUSIONS: The IS BT technique resulted in better dose-volume histogram parameters for large volume tumors (>5 cm) compared with the conventional IC BT and acceptable risk of acute complications in locally advanced cervical cancer and is clinically feasible.


Brachytherapy/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Uterine Cervical Neoplasms/diagnostic imaging , Uterine Cervical Neoplasms/radiotherapy , Brachytherapy/instrumentation , Female , Humans , Imaging, Three-Dimensional/instrumentation , Imaging, Three-Dimensional/methods , Middle Aged , Radiotherapy Planning, Computer-Assisted/instrumentation , Radiotherapy, Image-Guided/instrumentation , Tomography, X-Ray Computed/instrumentation , Tomography, X-Ray Computed/methods
4.
J Contemp Brachytherapy ; 8(5): 415-421, 2016 Oct.
Article En | MEDLINE | ID: mdl-27895683

PURPOSE: Locally recurring cervical cancer after surgery and adjuvant radiotherapy remains a major therapeutic challenge. This paper presents a new therapeutic technique for such patients: interstitial brachytherapy (BT) guided by real-time three-dimensional (3D) computed tomography (CT). MATERIAL AND METHODS: Sixteen patients with recurrent cervical cancer after radical surgery and adjuvant external-beam radiotherapy (EBRT) were included in this study. These patients underwent high-dose-rate (HDR) interstitial BT with free-hand placement of metal needles guided by real-time 3D-CT. Six Gy in 6 fractions were prescribed for the high-risk clinical target volume (HR-CTV). D90 and D100 for HR-CTV of BT, and the cumulative D2cc for the bladder, rectum, and sigmoid, including previous EBRT and present BT were analyzed. Treatment-related complications and 3-month tumor-response rates were investigated. RESULTS: The mean D90 value for HR-CTV was 52.5 ± 3.3 Gy. The cumulative D2cc for the bladder, rectum, and sigmoid were 85.6 ± 5.8, 71.6 ± 6.4, and 69.6 ± 5.9 Gy, respectively. The mean number of needles was 6.1 ± 1.5, with an average depth of 3.5 ± 0.9 cm for each application. Interstitial BT was associated with minor complications and passable tumor-response rate. CONCLUSIONS: Interstitial BT guided by real-time 3D-CT for recurrent cervical cancer results in good dose-volume histogram (DVH) parameters. The current technique may be clinically feasible. However, long-term clinical outcomes should be further investigated.

5.
Brachytherapy ; 15(5): 562-9, 2016.
Article En | MEDLINE | ID: mdl-27474180

PURPOSE: To explore the dosimetric advantage of target volume and surrounding normal tissue by using interstitial (IS) brachytherapy (BT) based on three-dimensional CT in locally advanced cervical cancer, as a simple and effective clinical treatment approach. METHODS AND MATERIALS: Fifty-two patients with poor tumor response to external beam radiotherapy and a residual tumor >5 cm at the time of the first BT were included. IS BT was performed using a "hybrid" applicator combining uterine tandem and free metal needles based on three-dimensional CT. The high-risk clinical target volume (HR-CTV), intermediate-risk clinical target volume, and organs at risk were contoured. The total dose, including external beam radiotherapy (45 Gy in 25 fractions) and high-dose-rate BT (30 Gy in 5 fractions), was biologically normalized to conventional 2-Gy fractions. D90 and D100 for HR-CTV and intermediate-risk clinical target volume and D2cc for the bladder, rectum, and sigmoid were analyzed. RESULTS: The mean D90 value for HR-CTV was 88.4 ± 3.5 Gy. Totally, 88.5% of the patients received D90 for HR-CTV ≥87 Gy. The D2cc for the bladder, rectum, and sigmoid were 81.1 ± 5.6, 65.7 ± 5.1, and 63.1 ± 5.4 Gy, respectively. The mean number of needles was 6.9 ± 1.3 for each application. IS BT was associated with minor complications. CONCLUSION: IS BT using the "hybrid" applicator provides a dosimetric advantage for target volume and organs at risk in large-volume (>5 cm) tumors and is, thereby, clinically feasible. However, the long-term curative effect and possible toxicity need further clinical observation.


Brachytherapy/instrumentation , Organs at Risk , Uterine Cervical Neoplasms/diagnostic imaging , Uterine Cervical Neoplasms/radiotherapy , Adult , Aged , Brachytherapy/adverse effects , Brachytherapy/methods , Colon, Sigmoid , Feasibility Studies , Female , Humans , Imaging, Three-Dimensional , Middle Aged , Needles , Neoplasm, Residual , Radiotherapy Dosage , Rectum , Retreatment , Tomography, X-Ray Computed , Treatment Outcome , Tumor Burden , Urinary Bladder , Uterine Cervical Neoplasms/pathology
6.
Int J Clin Exp Med ; 8(4): 5499-505, 2015.
Article En | MEDLINE | ID: mdl-26131129

Long non-coding RNAs (lncRNAs) have been suggested to serve as an important role in tumor development and progression. The aim of this study was to analyse the association between lncRNA metastasis-associated lung adenocarcinoma transcript 1 (MALAT1) and cancer patients' overall survival. We systematically and carefully searched the studies from electronic databases and seriously identified according to eligibility criteria. The correlation between lncRNA MALAT1 expression and overall survival in human cancers was evaluated through Review Manager. A total of 8 studies which included 792 cancer patients were included in the final analysis. Meta-analysis showed that lncRNA MALAT1 overexpression was correlated with a poor overall survival and the pooled hazard ratio (HR) and corresponding 95% confidence interval (CI) was 1.94 (95% CI 1.59-2.38). From subgroup analyses, we present evidence that lncRNA MALAT1 overexpression was an unfavorable prognostic factor for patients' overall survival in non-small cell lung cancer and pancreatic cancer, the pooled HRs (95% CI) were 1.86 (95% CI 1.27-2.73) and 1.78 (95% CI 1.30-2.44), respectively. In conclusion, lncRNA MALAT1 is a potential prognostic factor in human cancers.

...