1.
Cancer Biol Ther ; 25(1): 2284849, 2024 12 31.
Article En | MEDLINE | ID: mdl-38051132

OBJECTIVE: This study aims to investigate the effect of red ginseng polysaccharide (RGP) on gastric cancer (GC) development and explore its mechanism. METHODS: GC cell lines AGS were treated with varying concentrations of RGP (50, 100, and 200 µg/mL). AGS cells treated with 200 µg/mL RGP were transfected with aquaporin 3 (AQP3) overexpression vector. Cell proliferation, viability, and apoptosis were evaluated by MTT, colony formation assay, and flow cytometry, respectively. Real-time quantitative reverse transcription PCR (qRT-PCR) was used to detect the expression of AQP3. The levels of Fe2+, malondialdehyde, and lactate dehydrogenase were measured using their respective detection kits, and the reactive oxygen species levels was determined by probe 2',7'-dichlorodihydrofluorescein diacetate. The expression of ferroptosis-related protein and PI3K/Akt pathway-related protein were assessed by western blot. In vivo experiments in nude mice were performed and the mice were divided into four groups (n = 5/group) which gavage administrated with 150 mg/kg normal saline, and 75, 150, 300 mg/kg RGP, respectively. Their tumor weight and volume were recorded. RESULTS: RGP treatment effectively inhibited the proliferation and viability of AGS cells in a dosage-dependent manner and induced apoptosis. It induced ferroptosis in AGS cells, as well as inhibiting the expression of PI3K/Akt-related proteins. AQP3 overexpression could reversed the effect of RGP treatment on ferroptosis. Confirmatory in vivo experiments showed that RGP could reduce the growth of implanted tumor, with increased RGP concentration resulting in greater tumor inhibitory effects. CONCLUSION: RGP might have therapeutic potential against GC, effectively inhibiting the proliferation and viability of AGS cells.


Ferroptosis , Panax , Stomach Neoplasms , Animals , Mice , Stomach Neoplasms/pathology , Proto-Oncogene Proteins c-akt/metabolism , Signal Transduction , Phosphatidylinositol 3-Kinases/metabolism , Down-Regulation , Aquaporin 3/genetics , Aquaporin 3/metabolism , Mice, Nude , Cell Proliferation , Panax/metabolism , Cell Line, Tumor
3.
Chin Med J (Engl) ; 131(13): 1584-1590, 2018 Jul 05.
Article En | MEDLINE | ID: mdl-29941712

BACKGROUND: Measuring total serum calcium is important for the diagnosis of diseases. Currently, results from commercial kits for calcium measurement are variable. Generally, the performance of serum calcium measurements is monitored by external quality assessment (EQA) or proficiency testing schemes. However, the commutability of the EQA samples and calibrators is often unknown, which limits the effectiveness of EQA schemes. The aim of this study was to evaluate the bias of serum calcium measurements and the commutability of processed materials. METHODS: Inductively coupled plasma mass spectrometry was applied as a comparative method, and 14 routine methods were chosen as test methods. Forty-eight serum samples from individual patients and 25 processed materials were quantified. A scatter plot was generated from patient samples, and 95% prediction intervals were calculated to evaluate the commutability of the processed materials and measurement bias at three concentration levels was used to determine the accuracy of routine assays. RESULTS: All assays showed high precision (total coefficient of variation [CV] <2.26%) and correlation coefficients (r > 0.99). For all assays, the mean bias for the 48 patient samples ranged from -0.13 mmol/L to 0.00 mmol/L (-5.61-0.01%), and the ranges for the three concentrations were -0.10-0.04 mmol/L (-5.71-2.35%), -0.14--0.01 mmol/L (-5.80--0.30%), and -0.19-0.04 mmol/L (-6.24-1.22%). The EQA samples, calibrators, and animal sera exhibited matrix effects in some assays; human serum pools were commutable in all assays; certificate reference materials were commutable in most assays, and only GBW09152 exhibited a matrix effect in one assay; and aqueous reference materials exhibited matrix effects in most assays. CONCLUSIONS: Biases for most assays were within the acceptable range, although the accuracy of some assays needs improvement. Human serum pools prepared from patient samples were commutable, and the other tested materials exhibited a matrix effect.


Calcium/blood , Mass Spectrometry , Animals , Biological Assay , Calibration , Humans , Reproducibility of Results
4.
Chin Med J (Engl) ; 130(9): 1079-1084, 2017 May 05.
Article En | MEDLINE | ID: mdl-28469104

BACKGROUND: Hemoglobin A1c (HbA1c) measurement is of great value for the diagnosis and monitoring of diabetes. Many manufacturers have developed various experiments to determine the HbA1c concentration. However, the longitudinal use of these tests requires strict quality management. This study aimed to analyze the quality of HbA1c measurement systems in China using six sigma techniques to help improve their performances. METHODS: A total of 135 laboratories were involved in this investigation in 2015. Bias values and coefficients of variation were collected from an HbA1c trueness verification external quality assessment program and an internal quality control program organized by the National Center of Clinical Laboratories in China. The sigma (σ) values and the quality goal index (QGI) were used to evaluate the performances of different groups, which were divided according to principles and instruments. RESULTS: The majority of participants (88, 65.2%) were scored as "improvement needed (σ < 3)", suggesting that the laboratories needed to improve their measurement performance. Only 8.2% (11/135) of the laboratories were scored as "world class (σ ≥ 6)". Among all the 88 laboratories whose σ values were below 3, 52 (59.1%) and 23 (26.1%) laboratories needed to improve measurement precision (QGI <8.0) and trueness (QGI >1.2), respectively; the remaining laboratories (13, 14.8%) needed to improve both measurement precision and trueness. In addition, 16.1% (5/31) and 15.0% (3/20) of the laboratories in "TOSOH" and "ARKRAY" groups, respectively, were scored as "world class", whereas none of the laboratories in "BIO-RAD" group were scored as "world class". CONCLUSIONS: This study indicated that, although participating laboratories were laboratories with better performance in China, the performances were still unsatisfactory. Actions should be taken to improve HbA1c measurement performance before we can include HbA1c assays in diabetes diagnosis in China.


Glycated Hemoglobin/metabolism , China , Diabetes Mellitus/blood , Diabetes Mellitus/metabolism , Humans , Quality Assurance, Health Care/methods
5.
Asian Pac J Cancer Prev ; 16(7): 2685-91, 2015.
Article En | MEDLINE | ID: mdl-25854347

To evaluate the clinical impact of preoperative serum CEA and CA19-9 on resectable gastric cancer (GC), a total of 1,075 consecutive cases with gastric adenocarcinoma were obtained retrospectively from January 2012 and December 2013 in a single tertiary hospital, and the relationships between serum CEA, CA19-9 and clinicopathologic features were investigated. Positive preoperative serum rates of CEA and CA19-9 were 22.4% and 12.3% respectively, levels significantly correlating with each other and depth of invasion, lymph node involvement, pTNM and stage. The CEA level also presented a remarkable association with lymphovascular invasion. Both CEA and CA19-9 positivity significantly and positively correlated with depth of invasion, nodal involvement, pTNM stage, lymphovascular invasion, tumor size and tumor location. Stratified analyses according to gender or tumor location showed preoperative CEA or CA19-9 had different associations with clinicopathologic features in different gender subgroups or location subgroups. Preoperative serum CA19-9 positivity may be more meaningful for tumor size rather than CEA. In conclusion, preoperative serum CEA and CA19-9 correlate with disease progression of GC, and may have applications in aiding more accurate estimation of tumor stage, decision of treatment choice and prognosis evaluation.


Adenocarcinoma/pathology , Biomarkers, Tumor/blood , CA-19-9 Antigen/blood , Carcinoembryonic Antigen/blood , Stomach Neoplasms/pathology , Adenocarcinoma/blood , Adenocarcinoma/surgery , Disease Progression , Female , Humans , Lymphatic Metastasis/pathology , Male , Middle Aged , Neoplasm Invasiveness/pathology , Retrospective Studies , Stomach Neoplasms/blood , Stomach Neoplasms/surgery , Tertiary Care Centers , Tumor Burden
6.
Zhonghua Yi Xue Za Zhi ; 90(14): 993-7, 2010 Apr 13.
Article Zh | MEDLINE | ID: mdl-20646652

OBJECTIVE: To evaluate the performance of tumor markers (TM) measurements in clinical laboratories by external quality assessment (EQA) and investigate the comparability of assays for TM. METHODS: Ten quality control sera specimens were distributed to 586 laboratories by global Express Mail Services (EMS) in March 2008 and tested twice with 5 specimens each time. Analytes were total prostate specific antigen (PSA), free PSA, carcinoembryonic antigen (CEA), alpha fetoprotein (AFP), human chorionic gonadotrophin (HCG), beta-HCG, carbohydrate antigen 19-9 (CA19-9), cancer antigen 15-3 (CA 15-3), cancer antigen 125 (CA125), beta-2-microglobulin and ferritin. The collected data were divided into peer groups according to analyzers or methods and the median of peer group was adopted as the target value (TV) separately after outlier removal. Two standard deviations of the median were set as the limit of difference. RESULTS: The first TM EQA results of 2008 showed that the pass percentage of all participating laboratories ranged from 87.3% (CA125) to 95.5% (beta-2-microglobulin). And the second batch ranged from 83.5% (HCG) to 94.0% (beta-2-microglobulin). The coefficient variances (CVs) of intra-group values determined by automatic analyzers were lesser than 15% for each test of every specimen. The CVs of radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA) were over 20% and 50% respectively. The inter-group medians of 9 tests showed CVs>20% with HCG 13.4% and ferritin 15.7%. The CV of paired medians of some automatic analyzers was small and showed no statistical significance (all Z<1.890, all P>0.05). CONCLUSION: The analytical performance of automatic analyzers is superior to RIA and ELISA. There is an excellent comparability within automatic analyzers for TM measurements and a lack of comparability within RIA and ELISA. Noncomparability is found in over 80% of TM assays.


Automation/methods , Biomarkers, Tumor/blood , Clinical Laboratory Techniques/methods , Quality Assurance, Health Care , Automation/standards , CA-19-9 Antigen/blood , Carcinoembryonic Antigen/blood , Clinical Laboratory Techniques/standards , Enzyme-Linked Immunosorbent Assay , Humans , Prostate-Specific Antigen/blood , Radioimmunoassay , alpha-Fetoproteins/analysis
...