Front Med (Lausanne) ; 8: 729523, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34513889

RESUMEN

Purpose: This study was conducted in order to compare the diagnostic classification of Bruch's membrane opening-minimum rim width (BMO-MRW) and RNFL thickness in normal myopic subjects by using optical coherence tomography (OCT). Methods: This cross-sectional study involved 75 healthy myopic subjects [spherical equivalent (SE) ≤ -0.5D] from April 2019 to January 2020. One eye of each subject was randomly selected for examination. BMO-MRW and peripapillary RNFL thickness were measured by spectral-domain OCT (Spectralis, Heidelberg Engineering GmbH, Heidelberg, Germany). All the subjects were divided into three groups: low myopic group (SE > -3D), moderate myopic group (-6D < SE ≤ -3D), and high myopic group (SE ≤ -6D). A nonparametric test was used to analyze the difference among groups. Linear regression was used to analyze the relationship between BMO-MRW/RNFL thickness and axial length/spherical equivalent. McNemar test was used to compare the diagnostic classification between BMO-MRW and RNFL thickness. Results: The RNFL thickness classified a significantly higher percentage of eyes as outside normal limits/borderline in at least 1 quadrant (BMO-MRW, 4%; RNFL thickness, 34.67%; p < 0.01). There was no significant correlation between BMO-MRW/RNFL thickness and AL/SE. The low myopia (SE > -3D) had a significantly lower percentage of eyes classified as outside normal limits/borderline in at least 1 quadrant than the moderate myopia (-6D < SE ≤ -3D) and high myopia (SE ≤ -6D) (low myopia, 12.5%; moderate/high myopia, 42.42%/50%; p < 0.05). Conclusion: BMO-MRW had a lower percentage of eyes classified as outside normal limits/borderline in at least 1 quadrant than RNFL thickness in normal myopic subjects. When referring to the diagnostic classification of RNFL thickness in myopic subjects, caution should be exercised in interpreting positive results. Further studies are needed to compare the diagnostic accuracy of these two measurements in myopic glaucoma patients.

2.
Front Med (Lausanne) ; 8: 705873, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34568368

RESUMEN

Purpose: To investigate the stability of intraocular lens (IOLs) with different haptics by swept-source anterior-segment optical coherence tomography (AS-OCT). Methods: Sixty-eight eyes from 55 patients received the implantation of Rayner 920H (Closed C-loop Group), Zeiss 509M (Plate Group) or Lenstec SOFTEC HD (C-loop Group) IOLs. The tilt and decentration of IOLs were evaluated using AS-OCT at least 1 month postoperatively. Results: Mean decentration and tilt of IOLs were 0.18 ± 0.12 mm (range 0.02 to 0.59 mm) and 5.63 ± 1.65° (range 2.2 to 9.6°) respectively. Decentration was significantly smaller in the plate haptic group (0.12 ± 0.06 mm) as compared to the C-loop group (0.22 ± 0.13 mm, P = 0.02). The tilt of IOL was also significantly smaller in the plate haptic group (4.96 ± 0.89°) as compared to the C-loop group (6.28 ± 1.83°, P = 0.01). There was marginal difference between the Closed C-loop group (5.52 ± 1.74°) and C-loop group (6.28 ± 1.83°, P = 0.07). Conclusions: The Plate-haptic IOLs should have better stability for the decentration and tilt than the C-loop design IOLs.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA