Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 291
1.
Ultrasonics ; 142: 107358, 2024 Jun 10.
Article En | MEDLINE | ID: mdl-38901149

Stiffness measurement using shear wave propagation velocity has been the most common non-invasive method for liver fibrosis assessment. The velocity is captured through a trace recorded by transient ultrasonographic elastography, with the slope indicating the velocity of the wave. However, due to various factors such as noise and shear wave attenuation, detecting shear wave trajectory on wave propagation maps is a challenging task. In this work, we made the first attempt to use deep learning methods for shear wave trajectory detection on wave propagation maps. Specifically, we adopted five deep learning models in this task and evaluated them by using a well-acknowledged metric based on EA-Angular-Score (EAA) and task-specific metric based on Young s-Score (Ys) in the line-detection field. Furthermore, we proposed an end-to-end framework based on a Transformer and Hough transform, named Transformer-enhanced Hough Transform (TEHT). It took a wave propagation map as input image and directly output the slope of the shear wave trajectory. The framework extracts multi-scale local features from wave propagation maps, employs a deformable attention mechanism for feature fusion, identifies the target line using the Hough transform's voting mechanism, and calculates the contribution of each scale through channel attention. Wave propagation maps from 68 patients were utilized in this study, with manual annotation performed by a rater who was trained as a radiologist, serving as the reference value. The evaluation revealed that the SLNet model exhibited F-measure of EA and Ys values as 40.33 % and 40.72 %, respectively, while the TEHT model showed F-measure of EA and Ys values as 80.96 % and 98.00 %, respectively. TEHT yielded significantly better performance than other deep learning models. Moreover, TEHT demonstrated strong concordance with the gold standard, yielding R2 values of 0.967 and 0.968 for velocity and liver stiffness, respectively. The present study therefore suggests the application of the TEHT model for assessing liver fibrosis owing to its superiority among the five deep learning models.

2.
Insights Imaging ; 15(1): 114, 2024 May 12.
Article En | MEDLINE | ID: mdl-38734997

OBJECTIVES: Liver transient elastography (TE) has been endorsed by the WHO as the first-line diagnostic tool for liver diseases. Although unreliable and invalid results caused by intercostal space (ICS)-associated factors (including excessive subcutaneous fat and a narrow ICS relative to the transducer size) and operator inexperience are not uncommon, no standard guidelines for ideal probe placement are currently available. Herein, we conducted a prospective observational study to identify an ideal measurement site and respiratory condition for TE by characterizing anatomical and biomechanical properties of the ICSs using ultrasound B-mode and elasticity imaging. METHODS: Intercostal ultrasound was performed pointwise at four specific sites in 59 patients to simultaneously measure the width, stiffness, and skin‒liver capsule distance (SCD) of the ICSs over the liver, under end-inspiratory and end-expiratory conditions. Intersections between the 8th ICS and anterior axillary line, the 7th ICS and anterior axillary line, the 8th ICS and mid-axillary line, and the 7th ICS and mid-axillary line were defined as Sites 1 to 4, respectively. RESULTS: Results indicated that Sites 2 and 3 presented greater intercostal width; Sites 3 and 4 displayed lower intercostal stiffness; Sites 2 and 3 exhibited a shorter SCD. The ICSs were significantly wider and stiffer at end-inspiration. Additionally, the liver was more easily visualized at Sites 1 and 3. CONCLUSION: We recommend Site 3 for TE probe placement owing to its greater width, lower stiffness, and smaller abdominal wall thickness. Performing TE at end-inspiration is preferred to minimize transducer-rib interferences. This study paves the way toward a standardized TE examination procedure. CRITICAL RELEVANCE STATEMENT: A standardized measurement protocol for WHO-recommended liver TE was first established to improve the success and efficiency of the examination procedure. KEY POINTS: WHO-recommended TE is unreliable or fails due to intercostal space-related factors. The 8th intercostal space on the mid-axillary line and end-inspiration are recommended. This standardized protocol aids in handling challenging cases and simplifies operational procedures.

3.
Ultrasonics ; 141: 107332, 2024 Jul.
Article En | MEDLINE | ID: mdl-38718460

BACKGROUND: Stroke is the second leading cause of death across the globe. Early screening and risk detection could provide early intervention and possibly prevent its incidence. Imaging modalities, including 1D-Transcranial Doppler Ultrasound (1D-TCD) or Transcranial Color-code sonography (TCCS), could only provide low spatial resolution or 2D image information, respectively. Notably, 3D imaging modalities including CT have high radiation exposure, whereas MRI is expensive and cannot be adopted in patients with implanted devices. This study proposes an alternative imaging solution for reconstructing 3D Doppler ultrasound geared towards providing a screening tool for the 3D vessel structure of the brain. METHODS: The system comprises an ultrasound phased array attached to a servo motor, which can rotate 180˚ at a speed of 2˚/s. We extracted the color Doppler ROI from the image before reconstructing it into a 3D view using a customized pixel-based algorithm. Different vascular diameters, flow velocity, and depth were tested using a vascular phantom with a pumped flow to confirm the system for imaging blood flow. These variables were set to mimic the vessel diameter, flow speed, and depth of the Circle of Willis (CoW) during a transcranial screening. RESULTS AND CONCLUSIONS: The lower values of absolute error and ratio were found in the larger vascular channels, and vessel diameter overrepresentation was observed. Under different flow velocities, such diameter overrepresentation in the reconstructed flow did not change much; however, it did change with different depths. Meanwhile, the setting of the velocity scale and the color gain affected the dimension of reconstructed objectives. Moreover, we presented a 3D image of CoW from a subject to demonstrate its potential. The findings of this work can provide a good reference for further studies on the reconstruction of the CoW or other blood vessels using Doppler imaging.


Circle of Willis , Imaging, Three-Dimensional , Phantoms, Imaging , Ultrasonography, Doppler, Transcranial , Circle of Willis/diagnostic imaging , Imaging, Three-Dimensional/methods , Ultrasonography, Doppler, Transcranial/methods , Humans , Algorithms , Cerebrovascular Circulation , Blood Flow Velocity
4.
Vis Comput Ind Biomed Art ; 7(1): 8, 2024 Apr 16.
Article En | MEDLINE | ID: mdl-38625580

This study addresses a limitation of prior research on pectoralis major (PMaj) thickness changes during the pectoralis fly exercise using a wearable ultrasound imaging setup. Although previous studies used manual measurement and subjective evaluation, it is important to acknowledge the subsequent limitations of automating widespread applications. We then employed a deep learning model for image segmentation and automated measurement to solve the problem and study the additional quantitative supplementary information that could be provided. Our results revealed increased PMaj thickness changes in the coronal plane within the probe detection region when real-time ultrasound imaging (RUSI) visual biofeedback was incorporated, regardless of load intensity (50% or 80% of one-repetition maximum). Additionally, participants showed uniform thickness changes in the PMaj in response to enhanced RUSI biofeedback. Notably, the differences in PMaj thickness changes between load intensities were reduced by RUSI biofeedback, suggesting altered muscle activation strategies. We identified the optimal measurement location for the maximal PMaj thickness close to the rib end and emphasized the lightweight applicability of our model for fitness training and muscle assessment. Further studies can refine load intensities, investigate diverse parameters, and employ different network models to enhance accuracy. This study contributes to our understanding of the effects of muscle physiology and exercise training.

5.
J Clin Med ; 13(8)2024 Apr 15.
Article En | MEDLINE | ID: mdl-38673561

(1) Background: Swallowing is a complex process that comprises well-timed control of oropharyngeal and laryngeal structures to achieve airway protection and swallowing efficiency. To understand its temporality, previous research adopted adherence measures and revealed obligatory pairs in healthy swallows and the effect of aging and bolus type on the variability of event timing and order. This study aimed to (i) propose a systemic conceptualization of swallowing physiology, (ii) apply sequence analyses, a set of information-theoretic and bioinformatic methods, to quantify and characterize swallowing temporality, and (iii) investigate the effect of aging and dysphagia on the quantified variables using sequence analyses measures. (2) Method: Forty-three participants (17 young adults, 15 older adults, and 11 dysphagic adults) underwent B-mode ultrasound swallowing examinations at the mid-sagittal plane of the submental region. The onset, maximum, and offset states of hyoid bone displacement, geniohyoid muscle contraction, and tongue base retraction were identified and sorted to form sequences which were analyzed using an inventory of sequence analytic techniques; namely, overlap coefficients, Shannon entropy, and longest common subsequence algorithms. (3) Results: The concurrency of movement sequence was found to be significantly impacted by aging and dysphagia. Swallowing sequence variability was also found to be reduced with age and the presence of dysphagia (H(2) = 52.253, p < 0.001, η2 = 0.260). Four obligatory sequences were identified, and high adherence was also indicated in two previously reported pairs. These results provided preliminary support for the validity of sequence analyses for quantifying swallowing sequence temporality. (4) Conclusions: A systemic conceptualization of human deglutition permits a multi-level quantitative analysis of swallowing physiology. Sequence analyses are a set of promising quantitative measurement techniques for point-of-care ultrasound (POCUS) swallowing examinations and outcome measures for swallowing rehabilitation and evaluation of associated physiological conditions, such as sarcopenia. Findings in the current study revealed physiological differences among healthy young, healthy older, and dysphagic adults. They also helped lay the groundwork for future AI-assisted dysphagia assessment and outcome measures using POCUSs. Arguably, the proposed conceptualization and analyses are also modality-independent measures that can potentially be generalized for other instrumental swallowing assessment modalities.

6.
Front Bioeng Biotechnol ; 12: 1372158, 2024.
Article En | MEDLINE | ID: mdl-38576448

Background: Trans-spinal electrical stimulation (tsES) to the intact spinal cord poststroke may modulate the cortico-muscular control in stroke survivors with diverse lesions in the brain. This work aimed to investigate the immediate effects of tsES on the cortico-muscular descending patterns during voluntary upper extremity (UE) muscle contractions by analyzing cortico-muscular coherence (CMCoh) and electromyography (EMG) in people with chronic stroke. Methods: Twelve chronic stroke participants were recruited to perform wrist-hand extension and flexion tasks at submaximal levels of voluntary contraction for the corresponding agonist flexors and extensors. During the tasks, the tsES was delivered to the cervical spinal cord with rectangular biphasic pulses. Electroencephalography (EEG) data were collected from the sensorimotor cortex, and the EMG data were recorded from both distal and proximal UE muscles. The CMCoh, laterality index (LI) of the peak CMCoh, and EMG activation level parameters under both non-tsES and tsES conditions were compared to evaluate the immediate effects of tsES on the cortico-muscular descending pathway. Results: The CMCoh and LI of peak CMCoh in the agonist distal muscles showed significant increases (p < 0.05) during the wrist-hand extension and flexion tasks with the application of tsES. The EMG activation levels of the antagonist distal muscle during wrist-hand extension were significantly decreased (p < 0.05) with tsES. Additionally, the proximal UE muscles exhibited significant decreases (p < 0.05) in peak CMCoh and EMG activation levels by applying tsES. There was a significant increase (p < 0.05) in LI of peak CMCoh of proximal UE muscles during tsES. Conclusion: The cervical spinal cord neuromodulation via tsES enhanced the residual descending excitatory control, activated the local inhibitory circuits within the spinal cord, and reduced the cortical and proximal muscular compensatory effects. These results suggested the potential of tsES as a supplementary input for improving UE motor functions in stroke rehabilitation.

7.
Sleep Breath ; 28(3): 1365-1372, 2024 Jun.
Article En | MEDLINE | ID: mdl-38499834

BACKGROUND AND PURPOSE: Bispectral Index (BIS) and University of Michigan Sedation Scale (UMSS) were two commonly used methods of monitoring the sedation depth, but their correlation was not clear. The purpose of this study is to ascertain if BIS correlates with UMSS in determining the sedation level during pediatric drug-induced sleep endoscopy (DISE). METHODS: One-hundred children, aged 36-143 months, with ASA I~II grade, were enrolled. They were subject to general anesthesia for an elective adenotonsillectomy. Two drug regimens were used. After UMSS ≥ 3, the sites of airway obstructions were located by checking the supraglottic airway structures with a fibrous laryngoscope. UMSS scores, BIS values, electromyography (EMG), and signal quality indices (SQIs) were recorded at the pre-medication and pre-DISE baseline (T0), 5 min subsequent to medication administration but prior to DISE initiation (T1), 1 min after DISE was initiated (T2), 1 min after DISE was completed (T3), 1 min subsequent to tracheal intubation (T4), 1 min following extubation (T5), and 30 min past extubation (T6). RESULTS: There were strong correlations between BIS monitor readings and UMSS scores for total and two regimens. Kappa values revealed moderate agreement between BIS and UMSS for total and two regimens. The agreement rates were 67.47% for the total, 61.43% for Regimen 1, and 73.42% for Regimen 2, respectively. CONCLUSION: BIS correlates with UMSS in determining the sedation level during pediatric DISE for two regimens. BIS might serve as an appropriate indicator of sedation intensity when UMSS could not be used.


Conscious Sedation , Endoscopy , Tonsillectomy , Humans , Male , Female , Child , Child, Preschool , Adenoidectomy , Hypnotics and Sedatives/administration & dosage , Consciousness Monitors , Anesthesia, General , Electromyography
8.
BMC Endocr Disord ; 24(1): 32, 2024 Mar 06.
Article En | MEDLINE | ID: mdl-38443883

BACKGROUND: Hyperlipidaemic acute pancreatitis (HLAP) has become the most common cause of acute pancreatitis (AP) not due to gallstones or alcohol (Mosztbacher et al, Pancreatology 20:608-616, 2020; Yin et al, Pancreas 46:504-509, 2017). Therapeutic plasma exchange (TPE) has been reported to be effective in reducing serum TG levels which is important in management of HLAP (World J Clin Cases 9:5794-803, 2021). However, studies on TPE are mostly focusing on cases reports, TPE remains poorly evaluated till date and need to be compared with conservative therapy with a well-designed study. METHODS: A retrospectively cohort study on HLAP patients between January 2003 and July 2023 was conducted. Factors correlated with efficacy of TPE were included in a propensity model to balance the confounding factors and minimize selection bias. Patients with and without TPE were matched 1:2 based on the propensity score to generate the compared groups. Lipid profiles were detected on admission and consecutive 7 days. The triglyceride (TG) level decline rates, percentage of patients to reach the target TG levels, early recurrence rate, local complications and mortality were compared between groups. RESULTS: A total of 504 HLAP patients were identified. Since TPE was scarcely performed on patients with TG < 11.3 mmol/L, 152 patients with TG level 5.65 to 11.3 mmol/L were excluded while 352 with TG ≧11.3 mmol/L were enrolled. After excluding 25 cases with incomplete data or pregnancy, 327 patients, of whom 109 treated without TPE while 218 treated with TPE, were included in data analysis. One-to-two propensity-score matching generated 78 pairs, 194 patients with well-balanced baseline characteristics. Of 194 patients enrolled after matching done, 78 were treated without while 116 with TPE. In the matched cohort (n = 194), patients treated with TPE had a higher TG decline rate in 48 h than those without TPE (70.00% vs 54.00%, P = 0.001); the early recurrence rates were 8.96% vs 1.83%, p = 0.055. If only SAP patients were analyzed, the early recurrence rates were 14.81% vs 0.00% (p = 0.026) respectively. For patients with CT severity index (CTSI) rechecked within 14 days, early CTSI improment rate were 40.90% vs 31.91%. Local complications checked 6 months after discharge were 44.12% vs 38.30%. Mortality was 1.28% vs 1.72%. No differences were found in early stage CTSI improment rate (P = .589), local complications (P = .451) or motality between two groups. CONCLUSIONS: TPE reduces TG levels more quickly in 48 h compared with those with conservative treatment, but no difference in the consecutive days. TPE tends to reduce the early recurrence rate comparing with conventional therapy, but TPE has no advantages in improving CTSI in early stage, and no improvement for outcomes including local complications and mortalty.


Hyperlipidemias , Pancreatitis , Female , Pregnancy , Humans , Plasma Exchange , Retrospective Studies , Cohort Studies , Acute Disease , Propensity Score , Pancreatitis/complications , Pancreatitis/therapy , Hyperlipidemias/complications , Hyperlipidemias/therapy , Triglycerides
9.
Angew Chem Int Ed Engl ; 63(20): e202402657, 2024 May 13.
Article En | MEDLINE | ID: mdl-38477874

The main group metals are commonly perceived as catalytically inert in the context of oxygen reduction reactions (ORR) due to the delocalized valence orbitals. Regulating the local environment and structure of metal center coordinated by nitrogen ligands (M-Nx) is a promising approach to accelerate catalytic dynamics. Herein, we, for the first time, report the atomically dispersed Al catalysts coordinated with N and C atoms for 4-electron ORR. The axial coordinated pyrrolyl N group (No) is constructed in the Al-N4-No moiety to regulate the p-band structure of Al center, effectively steering the local environment and structure of the square planar Al-N4 sites, which typically exhibit too strong interaction with ORR intermediates. The dynamic covalency competition of axial Al-No and Al-O bonding could endow the Al center with moderate hybridization between Al 3p orbital and O 2p orbital, alleviating the binding energy of ORR intermediates. The as-prepared Al-N4-No electrocatalyst exhibits excellent ORR activity, selectivity, and durability, along with the rapid kinetics as demonstrated by in situ Raman spectroscopy. This work offers a fundamental comprehension of the fine regulation on p-band and guides the rational design of main-group metal-based single atom catalysts.

10.
Ultrasound Med Biol ; 50(5): 647-660, 2024 05.
Article En | MEDLINE | ID: mdl-38355361

OBJECTIVE: Scoliosis is a spinal deformation in which the spine takes a lateral curvature, generating an angle in the coronal plane. The conventional method for detecting scoliosis is measurement of the Cobb angle in spine images obtained by anterior X-ray scanning. Ultrasound imaging of the spine is found to be less ionising than traditional radiographic modalities. For posterior ultrasound scanning, alternate indices of the spinous process angle (SPA) and ultrasound curve angle (UCA) were developed and have proven comparable to those of the traditional Cobb angle. In SPA, the measurements are made using the spinous processes as an anatomical reference, leading to an underestimation of the traditionally used Cobb angles. Alternatively, in UCA, more lateral features of the spine are employed for measurement of the main thoracic and thoracolumbar angles; however, clear identification of bony features is required. The current practice of UCA angle measurement is manual. This research attempts to automate the process so that the errors related to human intervention can be avoided and the scalability of ultrasound scoliosis diagnosis can be improved. The key objective is to develop an automatic scoliosis diagnosis system using 3-D ultrasound imaging. METHODS: The novel diagnosis system is a three-step process: (i) finding the ultrasound spine image with the most visible lateral features using the convolutional RankNet algorithm; (ii) segmenting the bony features from the noisy ultrasound images using joint spine segmentation and noise removal; and (iii) calculating the UCA automatically using a newly developed centroid pairing and inscribed rectangle slope method. RESULTS: The proposed method was evaluated on 109 patients with scoliosis of different severity. The results obtained had a good correlation with manually measured UCAs (R2=0.9784 for the main thoracic angle andR2=0.9671 for the thoracolumbar angle) and a clinically acceptable mean absolute difference of the main thoracic angle (2.82 ± 2.67°) and thoracolumbar angle (3.34 ± 2.83°). CONCLUSION: The proposed method establishes a very promising approach for enabling the applications of economic 3-D ultrasound volume projection imaging for mass screening of scoliosis.


Scoliosis , Humans , Scoliosis/diagnostic imaging , Spine/diagnostic imaging , Ultrasonography/methods , Radiography , Imaging, Three-Dimensional
11.
IEEE Trans Med Imaging ; PP2024 Feb 29.
Article En | MEDLINE | ID: mdl-38421850

In medical image analysis, anatomical landmarks usually contain strong prior knowledge of their structural information. In this paper, we propose to promote medical landmark localization by modeling the underlying landmark distribution via normalizing flows. Specifically, we introduce the flow-based landmark distribution prior as a learnable objective function into a regression-based landmark localization framework. Moreover, we employ an integral operation to make the mapping from heatmaps to coordinates differentiable to further enhance heatmap-based localization with the learned distribution prior. Our proposed Normalizing Flow-based Distribution Prior (NFDP) employs a straightforward backbone and non-problem-tailored architecture (i.e., ResNet18), which delivers high-fidelity outputs across three X-ray-based landmark localization datasets. Remarkably, the proposed NFDP can do the job with minimal additional computational burden as the normalizing flows module is detached from the framework on inferencing. As compared to existing techniques, our proposed NFDP provides a superior balance between prediction accuracy and inference speed, making it a highly efficient and effective approach. The source code of this paper is available at https://github.com/jacksonhzx95/NFDP.

12.
Natl Sci Rev ; 11(3): nwad323, 2024 Mar.
Article En | MEDLINE | ID: mdl-38312377

Tunability of optical performance is one of the key technologies for adaptive optoelectronic applications, such as camouflage clothing, displays, and infrared shielding. High-precision spectral tunability is of great importance for some special applications with on-demand adaptability but remains challenging. Here we demonstrate a galvanostatic control strategy to achieve this goal, relying on the finding of the quantitative correlation between optical properties and electrochemical reactions within materials. An electrochromic electro-optical efficiency index is established to optically fingerprint and precisely identify electrochemical redox reactions in the electrochromic device. Consequently, the charge-transfer process during galvanostatic electrochemical reaction can be quantitatively regulated, permitting precise control over the final optical performance and on-demand adaptability of electrochromic devices as evidenced by an ultralow deviation of <3.0%. These findings not only provide opportunities for future adaptive optoelectronic applications with strict demand on precise spectral tunability but also will promote in situ quantitative research in a wide range of spectroelectrochemistry, electrochemical energy storage, electrocatalysis, and material chemistry.

13.
Adv Mater ; 36(23): e2314247, 2024 Jun.
Article En | MEDLINE | ID: mdl-38332496

Aqueous dual-ion batteries (ADIBs) based on the cooperative redox of cations and iodine anions at the anode and cathode respectively, are attracting increasing interest because of high capacity and safety. However, the full-cell performance is limited by the sluggish iodine redox kinetics between iodide and polyiodide involving multiple electron transfer steps, and the undesirable shuttling effect of polyiodides. Here, this work reports a versatile conjugated microporous polymer functionalized with secondary amine groups as an organocatalytic cathode for ADIB, which can be positively charged and electrostatically adsorb iodide, and organocatalyze iodine redox reactions through the amine groups. Both theoretical calculations and controlled experiments confirm that the secondary amine groups confine (poly)iodide species via hydrogen bonding, which is essential for accelerating iodine redox kinetics and reducing the polyiodide shuttling effect. The ADIB achieves an ultrahigh capacity of 730 mAh g-1 with an ultrasmall overpotential of 47 mV at 1 A g-1, which also exhibits excellent rate performance and long cycling stability with a capacity retention of 74% after 5000 cycles at a high current density of 5 A g-1. This work demonstrates the promise of developing organocatalysts for accelerating electrochemical processes, which remains a virtually unexplored area in electrocatalyst design for clean energy applications.

14.
BMC Musculoskelet Disord ; 25(1): 32, 2024 Jan 04.
Article En | MEDLINE | ID: mdl-38178051

BACKGROUND: Adolescent idiopathic scoliosis (AIS) is the most common developmental spine disorder among children. It is characterized by a lateral deviation of the spine that gives rise to the distinctive "S" or "C" shaped bending of the spine. The Lin School of Lingnan Region (LSLR), one of the prominent schools for bare-handed orthopaedic manipulation in southern China, provides preliminary evidences that the orthopaedic manipulation techniques help to correct deviations of the spine. Previous research found that Orthopaedic Manipulation Techniques of LSLR (OMT-LSLR) could reduce the Cobb's angles in patients with AIS. Therefore, the current study aims to investigate the effectiveness and safety of the OMT-LSLR in treating teenagers with AIS. METHODS: In this participant-and-assessor-blinded randomized controlled clinical trial, 50 participants identified AIS without surgical indications will be recruited and randomized into two groups to receive physiotherapy scoliosis-specific exercises training with either orthopaedic manipulation or sham manipulation treatment for 16 weeks, followed by post-treatment visits at week 24. Primary outcome measure is the change of Scoliosis Research Society-22 (SRS-22) questionnaire score. Secondary outcome measures include Traditional Chinese version of Spinal Appearance Questionnaire (TC-SAQ) score, Italian Spine Youth Quality of Life (ISYQOL) score, the change of Cobb's angle measured by Xray, and the change of Cobb's angle, spinal rotation and muscle volume measured by three-dimensional (3D) ultrasound. The trial will be conducted at the Chinese University of Hong Kong Chinese Medicine Specialty Clinic cum Clinical Teaching and Research Centre in Hong Kong (CUHK-CMSCTRC). DISCUSSION: The results of this study will establish comprehensive clinical evidence about the efficacy and safety of the Orthopaedic Manipulation Techniques of the Lin School of Lingnan Region in the Treatment of Adolescent Idiopathic Scoliosis. One of the characteristics of this trial is that it is a participant-and-assessor-blinded randomized controlled clinical trial with sham manipulation. The study would also apply three-dimensional (3D) ultrasound technology to investigate the relationship between the change of the muscle volume and the spinal curve. TRIAL REGISTRATION: The trial is registered on ClinicalTrials.gov (Identifier: NCT05639023 ) on December 6, 2022.


Scoliosis , Child , Humans , Adolescent , Scoliosis/therapy , Scoliosis/surgery , Manipulation, Orthopedic , Quality of Life , Spine , Exercise Therapy/methods , Randomized Controlled Trials as Topic
15.
Diagnostics (Basel) ; 14(2)2024 Jan 15.
Article En | MEDLINE | ID: mdl-38248066

Transient elastography (TE), recommended by the WHO, is an established method for characterizing liver fibrosis via liver stiffness measurement (LSM). However, technical barriers remain towards point-of-care application, as conventional TE requires wired connections, possesses a bulky size, and lacks adequate imaging guidance for precise liver localization. In this work, we report the design, phantom validation, and clinical evaluation of a palm-sized TE system that enables simultaneous B-mode imaging and LSM. The performance of this system was validated experimentally using tissue-equivalent reference phantoms (1.45-75 kPa). Comparative studies against other liver elastography techniques, including conventional TE and two-dimensional shear wave elastography (2D-SWE), were performed to evaluate its reliability and validity in adults with various chronic liver diseases. Intra- and inter-operator reliability of LSM were established by an elastography expert and a novice. A good agreement was observed between the Young's modulus reported by the phantom manufacturer and this system (bias: 1.1-8.6%). Among 121 patients, liver stiffness measured by this system and conventional TE were highly correlated (r = 0.975) and strongly agreed with each other (mean difference: -0.77 kPa). Inter-correlation of this system with conventional TE and 2D-SWE was observed. Excellent-to-good operator reliability was demonstrated in 60 patients (ICCs: 0.824-0.913). We demonstrated the feasibility of employing a fully integrated phased array probe for reliable and valid LSM, guided by real-time B-mode imaging of liver anatomy. This system represents the first technical advancement toward point-of-care liver fibrosis assessment. Its small footprint, along with B-mode guidance capability, improves examination efficiency and scales up screening for liver fibrosis.

16.
Spine J ; 24(4): 692-720, 2024 Apr.
Article En | MEDLINE | ID: mdl-38008187

BACKGROUND CONTEXT: Children with adolescent idiopathic scoliosis (AIS) may show asymmetrical paraspinal muscle characteristics. PURPOSE: To summarize the evidence regarding: (1) the associations between various paraspinal muscle characteristics and spinal curvature; (2) whether paraspinal muscle properties significantly differed between children with and without AIS; and (3) whether baseline paraspinal muscle characteristics predicted curve progression. STUDY DESIGN/SETTING: Systematic literature review. METHODS: Five databases (CINAHL, Academic Search Premier, MEDLINE, Scopus, and PubMed) were searched from inception to May 2022. This protocol was registered in the PROSPERO database of systematic reviews CRD 42020171263. The Critical appraisal skills program, the Appraisal Tool for Cross-Sectional Studies and Quality In Prognosis Studies tool were used to evaluate the risk of bias of the included studies. The strength of evidence of each identified association was determined by the Grading of Recommendations Assessment, Development, and Evaluation System (GRADE). RESULTS: Of 1,530 identified citations, four cohort, 17 cross-sectional, and 23 case-control studies including 31 with low, nine with moderate and four with high risk of bias were included. Low to very low-strength evidence supported that the convex side of the curve had more type I muscle fibers, higher muscle volume and paraspinal muscle activity, while the concavity had more intramuscular fatty infiltration. Very low-strength evidence substantiated greater side-to-side surface electromyography signals during left trunk bending in prone lying, standing, and standing with perturbation between people with and without AIS. Also, low to very low-strength evidence supported that a larger side-to-side surface electromyography ratio at the lower end vertebra predicted curve progression. CONCLUSIONS: Our review highlights that paraspinal muscles on the concavity of the curve demonstrate consistent changes (ie, altered muscle-related gene expression, muscle atrophy, increased fatty infiltration, reduced type I fibers, and reduced muscle activity), which may be the cause or consequence.


Kyphosis , Scoliosis , Child , Humans , Adolescent , Paraspinal Muscles , Cross-Sectional Studies , Systematic Reviews as Topic , Spine
17.
Ultrasound Med Biol ; 50(3): 384-393, 2024 03.
Article En | MEDLINE | ID: mdl-38114347

OBJECTIVE: The aim of the work described here was to determine whether 3-D ultrasound can provide results comparable to those of conventional X-ray examination in assessing curve progression in patients with adolescent idiopathic scoliosis (AIS). METHODS: One hundred thirty-six participants with AIS (42 males and 94 females; age range: 10-18 y, mean age: 14.1 ± 1.9 y) with scoliosis of different severity (Cobb angle range: 10º- 85º, mean: of 24.3 ± 14.4º) were included. Each participant underwent biplanar low-dose X-ray EOS and 3-D ultrasound system scanning with the same posture on the same date. Participants underwent the second assessment at routine clinical follow-up. Manual measurements of scoliotic curvature on ultrasound coronal projection images and posterior-anterior radiographs were expressed as the ultrasound curve angle (UCA) and radiographic Cobb angle (RCA), respectively. RCA and UCA increments ≥5º represented a scoliosis progression detected by X-ray assessment and 3-D ultrasound assessment, respectively. RESULTS: The sensitivity and specificity of UCA measurement in detecting scoliosis progression were 0.93 and 0.90, respectively. The negative likelihood ratio of the diagnostic test for scoliosis progression by the 3-D ultrasound imaging system was 0.08. CONCLUSION: The 3-D ultrasound imaging method is a valid technique for detecting coronal curve progression as compared with conventional radiography in follow-up of AIS. Substituting conventional radiography with 3-D ultrasound is effective in reducing the radiation dose to which AIS patients are exposed during their follow-up examinations.


Kyphosis , Scoliosis , Male , Female , Humans , Adolescent , Child , Scoliosis/diagnostic imaging , Kyphosis/diagnostic imaging , Radiography , Ultrasonography , X-Rays
18.
J Clin Med ; 12(23)2023 Nov 28.
Article En | MEDLINE | ID: mdl-38068414

Spinal cord injuries (SCI) can result in sensory and motor dysfunctions, which were long considered permanent. Recent advancement in electrical neuromodulation has been proven to restore sensorimotor function in people with SCI. These stimulation protocols, however, were mostly invasive, expensive, and difficult to implement. In this study, transcutaneous electrical stimulation (tES) was used to restore over-ground walking of an individual with 21 years of chronic paralysis from a cervical SCI. After a total of 66 weeks of rehabilitation training with tES, which included standing, functional reaching, reclined sit-up, treadmill walking, and active biking, significant improvement in lower-limb volitional movements and overall light touch sensation were shown as measured by the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI) score. By the end of the study, the participant could walk in a 4-m walking test with the aid of a walking frame and ankle-foot orthoses. The successful sensorimotor recovery of our study participant sheds light on the future of non-invasive neuromodulation treatment for SCI paralysis.

19.
Biosensors (Basel) ; 13(12)2023 Nov 25.
Article En | MEDLINE | ID: mdl-38131758

Falls are a prevalent cause of injury among older people. While some wearable inertial measurement unit (IMU) sensor-based systems have been widely investigated for fall risk assessment, their reliability, validity, and identification ability in community-dwelling older people remain unclear. Therefore, this study evaluated the performance of a commercially available IMU sensor-based fall risk assessment system among 20 community-dwelling older recurrent fallers (with a history of ≥2 falls in the past 12 months) and 20 community-dwelling older non-fallers (no history of falls in the past 12 months), together with applying the clinical scale of the Mini-Balance Evaluation Systems Test (Mini-BESTest). The results show that the IMU sensor-based system exhibited a significant moderate to excellent test-retest reliability (ICC = 0.838, p < 0.001), an acceptable level of internal consistency reliability (Spearman's rho = 0.471, p = 0.002), an acceptable convergent validity (Cronbach's α = 0.712), and an area under the curve (AUC) value of 0.590 for the IMU sensor-based receiver-operating characteristic (ROC) curve. The findings suggest that while the evaluated IMU sensor-based system exhibited good reliability and acceptable validity, it might not be able to fully identify the recurrent fallers and non-fallers in a community-dwelling older population. Further system optimization is still needed.


Accidental Falls , Postural Balance , Humans , Aged , Reproducibility of Results , Risk Assessment/methods , ROC Curve
20.
Angew Chem Int Ed Engl ; 62(51): e202314509, 2023 Dec 18.
Article En | MEDLINE | ID: mdl-37884441

The pulverization of alloying anodes significantly restricts their use in lithium-ion batteries (LIBs). This study presents a dual-phase solid electrolyte interphase (SEI) design that incorporates finely dispersed Al nanoparticles within the LiPON matrix. This distinctive dual-phase structure imparts high stiffness and toughness to the integrated SEI film. In comparison to single-phase LiPON film, the optimized Al/LiPON dual-phase SEI film demonstrates a remarkable increase in fracture toughness by 317.8 %, while maintaining stiffness, achieved through the substantial dissipation of strain energy. Application of the dual-phase SEI film on an Al anode leads to a 450 % enhancement in cycling stability for lithium storage in dual-ion batteries. A similar enhancement in cycling stability for silicon anodes, which face severe volume expansion issues, is also observed, demonstrating the broad applicability of the dual-phase SEI design. Specifically, homogeneous Li-Al alloying has been observed in conventional LIBs, even when paired with a high mass loading LiNi0.5 Co0.3 Mn0.2 O2 cathode (7 mg cm-2 ). The dual-phase SEI film design can also accelerate the diffusion kinetics of Li-ions through interface electronic structure regulation. This dual-phase design can integrate stiffness and toughness into a single SEI film, providing a pathway to enhance both the structural stability and rate capability of alloying anodes.

...