Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
2.
ASAIO J ; 69(1): 101-106, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-35239536

RESUMEN

Postinfarct ventricular septal defect (PIVSD) is associated with high mortality and the management of these patients has been a challenge with little improvement in outcomes. We commenced a protocol of veno-arterial extracorporeal membrane oxygenation (VA ECMO) for those patients who present in cardiogenic shock with the aim to improve end-organ function before definitive surgical repair to reduce postoperative mortality. This study reviewed the results of this strategy. This was a single-center, retrospective review of all patients who were admitted to our institution with PIVSD in cardiogenic shock from September 2015 to November 2019. Clinical and investigative data were evaluated. Eight patients were referred with PIVSD during this period in cardiogenic shock. One patient had an anterior PIVSD and the other seven had inferior PIVSD. Six patients underwent surgical repair at a median (interquartile range, IQR) of 7 (5-8) days after initiation of VA ECMO. Two patients did not undergo surgical repair. Five patients survived after surgery and one patient died postoperatively due to multiorgan failure. Preoperative use of VA ECMO is a feasible strategy for PIVSD and may improve the results of repair.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Defectos del Tabique Interventricular , Humanos , Choque Cardiogénico/etiología , Choque Cardiogénico/cirugía , Oxigenación por Membrana Extracorpórea/métodos , Defectos del Tabique Interventricular/cirugía , Estudios Retrospectivos , Muerte
3.
Ann Thorac Surg ; 115(2): e63-e65, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35738402

RESUMEN

Heart-lung transplantation is a mature therapy but has perioperative complications, such as phrenic nerve dysfunction and mediastinal bleeding. We report our technical modifications to simplify the procedure.


Asunto(s)
Trasplante de Corazón-Pulmón , Trasplante de Pulmón , Humanos , Trasplante de Corazón-Pulmón/métodos , Mediastino , Nervio Frénico/cirugía , Hemorragia
4.
JACC Case Rep ; 4(15): 977-981, 2022 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-35935148

RESUMEN

We present the case of acute myocardial infarction secondary to spontaneous coronary artery dissection in a patient 2 weeks post orthotopic heart transplantation. (Level of Difficulty: Advanced.).

5.
Heart Lung Circ ; 31(5): 711-715, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34838453

RESUMEN

BACKGROUND: Problematic mitral regurgitation (MR) may develop following lung transplantation (LTx). There is limited information on the management of MR in LTx patients, as such we sought to evaluate our centre's experience. METHODS: From 2000 to 2019, 1,054 patients underwent LTx at our centre (896 bilateral, 158 single). We identified patients in whom significant MR developed at any point post-LTx. The aetiology of MR, management and outcome were retrospectively analysed. RESULTS: Eight (8) patients developed severe MR post-LTx, six following bilateral LTx and two following single LTx. Lung transplantation indications included interstitial lung disease (n=5), chronic obstructive pulmonary disease (n=2) and pulmonary arterial hypertension (n=1). Severe MR occurred intraoperatively (n=1), postoperative day 1 (n=1) with the remaining six cases between 80 and 263 days post-LTx. The aetiology was noted to be due to severe left ventricular dysfunction following unmasking of a chronically pulmonary hypertension-related under-preloaded left ventricle in one case, and in the remaining seven patients causes included myxomatous degeneration, ischaemic MR, and functional MR due to annular dilatation. In the patient with intraoperative severe MR, the MR became mild with veno-arterial extracorporeal membrane oxygenation (VA-ECMO) and in the remaining seven patients a variety of procedures were used, including mitral valve repair, valve replacement and transcatheter edge-to-edge mitral valve repair. All patients survived the mitral procedure. Two (2) deaths occurred at 12.9 years (stroke) and 5 years (cancer) from mitral valve surgery. CONCLUSIONS: Development of significant mitral valve regurgitation is a rare but morbid complication after lung transplantation. This may represent the progressive natural history of pre-existing degenerative mitral valve disease and rarely, early after transplantation may be related to changes in ventricular geometry. Management of severe MR can follow the same management approach as in the non-transplant community, with the expectation of similarly good results.


Asunto(s)
Trasplante de Pulmón , Insuficiencia de la Válvula Mitral , Humanos , Trasplante de Pulmón/efectos adversos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
6.
Curr Cardiol Rev ; 17(5): e160721192831, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33855948

RESUMEN

Optimal management of heart failure is collaborative, with the involvement of specialist heart failure physicians, nurses, interventionalists, and surgeons. In addition to medical optimisation and cardiac resynchronisation therapy, surgery plays a valuable role in many patients. We herein study the evidence and the role of surgical intervention in functional mitral regurgitation, coronary revascularisation in ischaemic cardiomyopathy, and surgical ventricular reconstruction. Additionally, we describe techniques of temporary and durable mechanical circulatory support, with their relative advantages and disadvantages, and applications. Finally, we describe the history and nomenclature around heart transplants, their indications, techniques, present-day outcomes, complications, and new developments in the field.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Isquemia Miocárdica , Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
7.
J Heart Lung Transplant ; 40(3): 193-200, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33423854

RESUMEN

BACKGROUND: Right ventricular (RV) failure after left ventricular assist device (VAD) implantation is a difficult problem. One solution is the implantation of continuous-flow VADs in a biventricular configuration. Disappointing survival and a concerning incidence of right-sided pump thrombosis have been previously reported. METHODS: From May 2017 to April 2020, a total of 12 patients underwent implantation of HeartMate 3 (HM3) biventricular VADs (BiVADs) as a bridge to cardiac transplantation. The right-sided pump was implanted in the right atrium in all cases. Adverse events and patient outcomes were determined. RESULTS: Patients were male, and the mean age was 44 years. The etiology was dilated cardiomyopathy (6 patients), sarcoid heart disease (2 patients), ischemic cardiomyopathy (1 patient), anthracycline cardiomyopathy (1 patient), non-compaction cardiomyopathy (1 patient), and arrhythmogenic RV cardiomyopathy with biventricular involvement (1 patient). There was 1 death from multisystem failure. There were 3 episodes of right VAD thrombus (thrombosis or clot ingestion); 1 managed medically, 1 recognized intraoperatively treated with clot retrieval, and 1 requiring pump exchange. There were 3 driveline infections. At 18 months after the procedure, 5 patients (41.7%) had undergone cardiac transplantation, 5 patients (41.7%) were alive and on biventricular support, 1 patient had died (8.3%), and 1 patient had VAD explantation for myocardial recovery (8.3%). Actuarial survival at 18 months was 91.7%. CONCLUSIONS: In this small study, HM3 BiVAD in these critically ill patients was used with low mortality. This suggests that the timely deployment of biventricular support with HM3 can be associated with favorable outcomes.


Asunto(s)
Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Corazón Auxiliar , Adolescente , Adulto , Ecocardiografía , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/diagnóstico , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Adulto Joven
8.
J Heart Lung Transplant ; 39(11): 1289-1299, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32771438

RESUMEN

BACKGROUND: Driveline infections remain a major complication of ventricular assist device (VAD) implantation. This study aimed to characterize in vivo microbial biofilms associated with driveline infections and host tissue integration of implanted drivelines. METHODS: A total of 9 infected and 13 uninfected drivelines were obtained from patients with VAD undergoing heart transplantation in Australia between 2016 and 2018. Each driveline was sectioned into 11 pieces of 1.5 cm in length, and each section was examined by scanning electron microscopy (SEM) and viable counts for microbial biofilms. Microorganisms were cultured and identified. Host tissue integration of clinical drivelines was assessed with micro-computed tomography (CT) and SEM. An in vitro interstitial biofilm assay was used to simulate biofilm migration in the driveline tunnel, and time-lapse microscopy was performed. RESULTS: Of the 9 explanted, infected drivelines, all had organisms isolated from varying depths along the velour section of the drivelines, and all were consistent with the swab culture results of the clinically infected exit site. SEM and micro-CT suggested insufficient tissue integration throughout the driveline velour, with microgaps observed. Clinical biofilms presented as microcolonies within the driveline tunnel, with human tissue as the sub-stratum, and were resistant to anti-microbial treatment. Biofilm migration mediated by a dispersal-seeding mechanism was observed. CONCLUSIONS: This study of explanted infected drivelines showed extensive anti-microbial-resistant biofilms along the velour, associated with microgaps between the driveline and the surrounding tissue. These data support the enhancement of tissue integration into the velour as a potential preventive strategy against driveline infections by preventing biofilm migration that may use microgaps as mediators.


Asunto(s)
Biopelículas , Corazón Auxiliar/efectos adversos , Infecciones Relacionadas con Prótesis/diagnóstico , Microtomografía por Rayos X/métodos , Estudios de Seguimiento , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/microbiología , Humanos , Estudios Prospectivos
9.
Emerg Med Australas ; 32(4): 657-662, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32400039

RESUMEN

OBJECTIVE: The objective of this study was to report the procedural incidence and patient outcomes after the 2009 introduction of an institutional resuscitative thoracotomy (RT) programme. Emergency physicians, general surgeons and emergency nursing trauma team members were trained to perform RT on thoracic trauma patients with an unresponsive systolic blood pressure (SBP) <70 mmHg within 30 min of arrival, prior to cardiothoracic team back-up. METHODS: A retrospective cohort study was conducted on patients who underwent RT from 2009 to 2017. The primary outcome measures were the incidence of the procedure and patients' survival to hospital discharge. Variables associated with survival were assessed using univariable logistic regression analyses. RESULTS: There were 12 399 major trauma patients, including 7657 with major thoracic trauma and 315 presenting with SBP <70 mmHg. There were 32 RTs performed (incidence of 0.4%; 95% confidence interval [CI] 0.3-0.6) among patients with major thoracic trauma and 10.2% (99% CI 7.3-13.4) among patients with major thoracic trauma and SBP <70 mmHg. There were eight (25%; 95% CI 13.2-42.1) survivors to hospital discharge and no late mortality (mean follow-up 2.8 years). Survival was significantly associated with the procedure performed within 30 min of arrival (odds ratio 0.09; 95% CI 0.01-0.67) while mortality was associated with the procedure being performed in the setting of traumatic cardiac arrest (odds ratio 18.3; 95% CI 2.4-140.4). CONCLUSIONS: A formal training and credentialing programme was associated with a low incidence of the procedure, yet achieved a survival rate of 25%, which is comparable to other reported literature.


Asunto(s)
Traumatismos Torácicos , Toracotomía , Adulto , Servicio de Urgencia en Hospital , Humanos , Resucitación , Estudios Retrospectivos , Traumatismos Torácicos/cirugía , Centros Traumatológicos
10.
J Heart Lung Transplant ; 39(1): 53-61, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31636045

RESUMEN

BACKGROUND: A donor arterial PO2/FiO2 (P/F ratio) of less than the 300 threshold would frequently result in either exclusion of the donor or placement of the lungs on ex vivo lung perfusion (EVLP). The aim was to investigate the veracity of the P/F ratio threshold of 300 for donor lung acceptability. METHODS: In 93 brain dead lung donors, arterial blood gases were drawn in the intensive care unit (ICU) just before procurement and each of the 4 donor pulmonary veins in the operating room (OR). No donor lungs were rejected for transplantation based on the last ICU or OR P/F ratio, and EVLP was not used. The recipients were followed up 6 and 12 months following transplantation. RESULTS: There were 93 recipients of bilateral lung transplantation. An arterial P/F ratio of < 300 was largely driven by a low P/F ratio in the lower lobes. There were no differences between the recipients receiving donor lungs where the ICU P/F ratio was < 300 compared with ≥ 300 in the time to extubation, grade of primary graft dysfunction, pulmonary function at 6 and 12 months, and 12-month survival. CONCLUSIONS: From this study:(1) If a donor P/F threshold of 300 was adhered to, 36% would have been rejected, and (2) The donor P/F ratio threshold of 300 is excessively conservative and results in the wastage of donor lungs and the application of unnecessary EVLP.


Asunto(s)
Circulación Extracorporea/métodos , Supervivencia de Injerto/fisiología , Trasplante de Pulmón/métodos , Pulmón/metabolismo , Preservación de Órganos/métodos , Perfusión/métodos , Donantes de Tejidos , Adulto , Femenino , Estudios de Seguimiento , Humanos , Pulmón/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Prospectivos
12.
J Thorac Cardiovasc Surg ; 156(4): 1589-1595.e1, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29778340

RESUMEN

OBJECTIVE: Midline sternotomy remains the most common access incision for cardiac operations. Traditionally, the sternum is closed with stainless steel wires. Wires are well known to stretch and break, however, leading to pain, nonunion, and potential deep sternal wound infection. We hypothesized that biocompatible plastic cable ties would achieve a more rigid sternal fixation, reducing postoperative pain and analgesia requirements. METHODS: A prospective, randomized study compared the ZIPFIX (De Puy Synthes, West Chester, Pa) sternal closure system (n = 58) with standard stainless steel wires (n = 60). Primary outcomes were pain and analgesia requirements in the early postoperative period. Secondary outcome was sternal movement, as assessed by ultrasound at the postoperative follow-up visit. RESULTS: Groups were well matched in demographic and operative variables. There were no significant differences between groups in postoperative pain, analgesia, or early ventilatory requirements. Patients in the ZIPFIX group had significantly more movement in the sternum and manubrium on ultrasound at 4 weeks. CONCLUSIONS: ZIPFIX sternal cable ties provide reliable closure but no demonstrable benefit in this study in pain or analgesic requirements relative to standard wire closure after median sternotomy.


Asunto(s)
Materiales Biocompatibles , Hilos Ortopédicos , Polímeros , Acero Inoxidable , Esternotomía , Técnicas de Cierre de Heridas/instrumentación , Anciano , Analgésicos/administración & dosificación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Dolor Postoperatorio/etiología , Dolor Postoperatorio/prevención & control , Estudios Prospectivos , Esternotomía/efectos adversos , Factores de Tiempo , Resultado del Tratamiento , Victoria , Técnicas de Cierre de Heridas/efectos adversos
13.
Innovations (Phila) ; 13(2): 97-103, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29697598

RESUMEN

OBJECTIVE: Leg ischemia is a serious complication of femoral artery cannulation. The primary aim of this study was to assess the safety and efficacy of a novel bidirectional femoral arterial cannula (Sorin Group USA, a wholly owned subsidiary of LivaNova PLC, Arvada, CO USA) that provides both antegrade and retrograde flow, in patients undergoing peripheral cannulation for cardiopulmonary bypass during cardiac surgery. METHODS: Patients undergoing routine cardiac surgery requiring femoral artery cannulation for cardiopulmonary bypass were identified preoperatively. Informed written consent was obtained in all cases. Bidirectional cannula insertion used either a surgical cut-down and wire through needle approach or a percutaneous technique. Flow in the superficial femoral artery was assessed using Doppler ultrasound after commencement of cardiopulmonary bypass. Lower limb perfusion was assessed using reflectance near-infrared spectroscopy to measure regional oxygen saturations in the cannulated limb during cardiopulmonary bypass. RESULTS: Fifteen patients (median age = 61.3 years, range = 26-79 years, 10 males, 5 females) underwent femoral arterial cannulation using the novel bidirectional femoral cannula between August 2016 and May 2017. Fourteen cannulae were inserted directly into the femoral artery via a surgical cut-down and wire through needle technique. One bidirectional cannula was inserted using a percutaneous insertion technique. Indications included minimally invasive mitral and aortic valve surgery, thoracic aortic aneurysm repair, and redo cardiac surgery. The median duration of cardiopulmonary bypass was 129 minutes (range = 53-228 minutes). The cannula was inserted and positioned without difficulty in 14 of 15 patients. Incorrect sizing and arterial spasm prevented correct cannula positioning in one patient. Antegrade flow in the superficial femoral artery was observed on Doppler ultrasound in 12 of 12 patients in which this was performed. Continuous stable distal perfusion was demonstrated in the cannulated limb in 14 of 15 patients. No procedural complications occurred in the immediate or convalescent postoperative period. CONCLUSIONS: This study demonstrates that in patients undergoing femoral arterial cannulation for cardiopulmonary bypass during cardiac surgery, the use of a novel bidirectional cannula is safe and easy to insert and provides stable distal perfusion of the cannulated limb. Use of the device should largely obviate the need to insert a separate downstream perfusion cannula or use other techniques to protect against lower limb ischemia. Further research on a larger scale and in different patient populations is now warranted.


Asunto(s)
Cánula/normas , Procedimientos Quirúrgicos Cardíacos/métodos , Cateterismo Periférico/métodos , Arteria Femoral/cirugía , Perfusión/instrumentación , Enfermedades Vasculares Periféricas/complicaciones , Adulto , Anciano , Aneurisma de la Aorta Torácica/cirugía , Válvula Aórtica/cirugía , Puente Cardiopulmonar/métodos , Puente Cardiopulmonar/estadística & datos numéricos , Cateterismo Periférico/efectos adversos , Diseño de Equipo , Femenino , Arteria Femoral/diagnóstico por imagen , Humanos , Isquemia/patología , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Válvula Mitral/cirugía , Enfermedades Vasculares Periféricas/diagnóstico por imagen , Enfermedades Vasculares Periféricas/patología , Espectroscopía Infrarroja Corta/métodos , Ultrasonografía Doppler
14.
Heart Lung Circ ; 27(8): 961-966, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29525135

RESUMEN

There is an ever increasing demand for donor lungs in patients waiting for transplantation. Lungs of many potential donors will be rejected if the standard criteria for donor assessment are followed. We have expanded our donor lung pool by accepting marginal donors and establishing a donation after circulatory death program. We have achieved comparable results using marginal donors and accepting donor lungs following donation after circulatory death. We present our assessment and technical guidelines on lung procurement taking into consideration an increasingly complex cohort of lung donors. These guidelines form the basis of the lung procurement training program involving surgical Fellows at the Alfred Hospital in Melbourne, Australia.


Asunto(s)
Educación de Postgrado en Medicina , Trasplante de Pulmón/educación , Pulmón/cirugía , Cirujanos/educación , Donantes de Tejidos , Obtención de Tejidos y Órganos/métodos , Humanos
15.
Innovations (Phila) ; 12(5): 370-374, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29023352

RESUMEN

OBJECTIVE: Sternal bleeding during cardiac surgery is currently controlled using bone wax or other chemical substances that may result in adverse effects and affect wound healing and recovery. The purpose of this study was to identify a safe, cost-effective, and easy-to-use technique to reduce sternal bleeding and sternal trauma during cardiac surgery. METHODS: After sternotomy, a sternal protection device was placed over each hemisternal section before insertion of the retractor and remained in situ until the end of surgery. Sternal bleeding and ease of use were assessed and recorded during surgery. Sternal trauma was assessed and recorded within 5 minutes of removal of the device, and overall satisfaction (Global Impression) and any intraoperative adverse events or device malfunction were reported at surgery completion. Patients were followed up 24 hours and 4 weeks after surgery. RESULTS: Twelve patients completed the study. Adverse events reported were not considered related to the device. No sternal trauma was identified in any patient. In 9 of 11 patients, sternal bleeding was reduced after insertion of the device. The device was generally considered easy to use, although some difficulty was encountered when used with the Internal Mammary Artery retractor. CONCLUSIONS: Our data suggest that the device is safe and able to reduce sternal bleeding during surgery using sternal retractors. We recommend further studies in a larger population of patients with a control group to evaluate the device's ability to reduce the morbidity associated with sternal bleeding and sternal trauma.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/instrumentación , Hemorragia/prevención & control , Revascularización Miocárdica/instrumentación , Equipos de Seguridad/normas , Esternotomía/instrumentación , Esternón/cirugía , Anciano , Válvula Aórtica/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Puente de Arteria Coronaria/métodos , Femenino , Humanos , Masculino , Arterias Mamarias/cirugía , Persona de Mediana Edad , Revascularización Miocárdica/métodos , Palmitatos/efectos adversos , Palmitatos/uso terapéutico , Proyectos Piloto , Esternotomía/métodos , Estrés Mecánico , Instrumentos Quirúrgicos/efectos adversos , Resultado del Tratamiento , Ceras/efectos adversos , Ceras/uso terapéutico , Cicatrización de Heridas
16.
Asian Cardiovasc Thorac Ann ; 25(1): 65-66, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26691582

RESUMEN

A right atrial mass was incidentally detected in an immunosuppressed 49-year-old woman 5 years after successful bilateral lung transplantation. The mass was surgically excised and found to be an organized thrombus. There was no clear mechanism for the de-novo thrombus formation. The potential mechanisms include immunosuppression-related thrombogenicity, transient pericarditis, and stasis of blood from persisting pulmonary hypertension.


Asunto(s)
Cardiopatías/etiología , Trasplante de Pulmón/efectos adversos , Trombosis/etiología , Ecocardiografía Transesofágica , Femenino , Atrios Cardíacos/diagnóstico por imagen , Cardiopatías/diagnóstico por imagen , Cardiopatías/cirugía , Humanos , Huésped Inmunocomprometido , Inmunosupresores/uso terapéutico , Persona de Mediana Edad , Factores de Riesgo , Trombectomía , Trombosis/diagnóstico por imagen , Trombosis/cirugía , Factores de Tiempo , Resultado del Tratamiento
17.
J Heart Lung Transplant ; 35(11): 1358-1364, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27311376

RESUMEN

BACKGROUND: Donation after circulatory death (DCD) represents a potential new source of hearts to increase the donor pool. We showed previously that DCD hearts in Greyhound dogs could be resuscitated and preserved by continuous cold crystalloid perfusion but not by cold static storage and could demonstrate excellent contractile and metabolic function on an in vitro system. In the current study, we demonstrate that resuscitated DCD hearts are transplantable. METHODS: Donor Greyhound dogs (n = 12) were divided into perfusion (n = 8) and cold static storage (n = 4) groups. General anesthesia was induced and ventilation ceased for 30 minutes to achieve circulatory death. Donor cardiectomy was performed, and for 4 hours the heart was preserved by controlled reperfusion, followed by continuous cold perfusion with an oxygenated crystalloid perfusate or by static cold storage, after which orthotopic heart transplantation was performed. Recovery was assessed over 4 hours by hemodynamic monitoring. RESULTS: During cold perfusion, hearts showed continuous oxygen consumption and low lactate levels, indicating aerobic metabolism. The 8 dogs in the perfusion group were weaned off bypass, and 4 hours after bypass produced cardiac output of 4.73 ± 0.51 liters/min, left ventricular power of 7.63 ± 1.32 J/s, right ventricular power of 1.40 ± 0.43 J/s, and left ventricular fractional area shortening of 39.1% ± 5.2%, all comparable to pre-transplant values. In the cold storage group, 3 of 4 animals could not be weaned from cardiopulmonary bypass, and the fourth exhibited low-level function. CONCLUSIONS: Cold crystalloid perfusion, but not cold static storage, can resuscitate and preserve the DCD donor heart in a canine model of heart transplantation, thus rendering it transplantable. Controlled reperfusion and cold crystalloid perfusion have potential for clinical application in DCD transplantation.


Asunto(s)
Cardiopatías/cirugía , Trasplante de Corazón/métodos , Soluciones Isotónicas/farmacología , Preservación de Órganos/métodos , Perfusión/métodos , Donantes de Tejidos , Obtención de Tejidos y Órganos/métodos , Animales , Criopreservación , Soluciones Cristaloides , Modelos Animales de Enfermedad , Perros , Soluciones para Rehidratación
18.
Int J Cardiol ; 202: 44-8, 2016 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-26386918

RESUMEN

The incidence of isolated tricuspid valve infective endocarditis is increasing. Medical management is the mainstay of treatment but surgical intervention is required in a subset of patients. Surgical treatment options include valve excision and replacement or valve reconstruction. We searched PubMed and the Cochrane library to identify articles to be included in this review of surgical outcomes. References of selected articles were crosschecked for other relevant studies. Surgical management of tricuspid valve endocarditis can be achieved with satisfactory outcomes. However, the optimal indication and timing of surgery remain unclear, and the frequent association with intravenous drug use complicates management. Repair techniques are preferable though there is no clear evidence supporting one method over another.


Asunto(s)
Endocarditis/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas , Válvula Tricúspide/cirugía , Endocarditis/complicaciones , Enfermedades de las Válvulas Cardíacas/etiología , Humanos , Diseño de Prótesis
19.
Artif Organs ; 40(1): 100-6, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25980985

RESUMEN

In patients requiring left ventricular assist device (LVAD) support, it can be difficult to ascertain suitability for long-term mechanical support with LVAD and eventual transplantation. LVAD implantation in a shocked patient is associated with increased morbidity and mortality. Interest is growing in the utilization of extracorporeal life support (ECLS) as a bridge-to-bridge support for these critically unwell patients. Here, we reviewed our experience with ECLS double bridging. We hypothesized that ECLS double bridging would stabilize end-organ dysfunction and reduce ventricular assist device (VAD) implant perioperative mortality. We conducted a retrospective review of prospectively collected data for 58 consecutive patients implanted with a continuous-flow LVAD between January 2010 and December 2013 at The Alfred Hospital, Melbourne, Victoria, Australia. Twenty-three patients required ECLS support pre-LVAD while 35 patients underwent LVAD implantation without an ECLS bridge. Preoperative morbidity in the ECLS bridge group was reflected by increased postoperative intensive care duration, blood loss, blood product use, and postoperative renal failure, but without negative impact upon survival when compared with the no ECLS group. ECLS stabilization improved end-organ function pre-VAD implant with significant improvements in hepatic and renal dysfunction. This series demonstrates that the use of ECLS bridge to VAD stabilizes end-organ dysfunction and reduces VAD implant perioperative mortality from that traditionally reported in these "crash and burn" patients.


Asunto(s)
Oxigenación por Membrana Extracorpórea/instrumentación , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Oxigenadores de Membrana , Adulto , Oxigenación por Membrana Extracorpórea/efectos adversos , Oxigenación por Membrana Extracorpórea/mortalidad , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda , Victoria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...