Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 5 de 5
1.
Biomed Opt Express ; 5(7): 2037-53, 2014 Jul 01.
Article En | MEDLINE | ID: mdl-25071947

A multi-center study has been set up to accurately characterize the optical properties of diffusive liquid phantoms based on Intralipid and India ink at near-infrared (NIR) wavelengths. Nine research laboratories from six countries adopting different measurement techniques, instrumental set-ups, and data analysis methods determined at their best the optical properties and relative uncertainties of diffusive dilutions prepared with common samples of the two compounds. By exploiting a suitable statistical model, comprehensive reference values at three NIR wavelengths for the intrinsic absorption coefficient of India ink and the intrinsic reduced scattering coefficient of Intralipid-20% were determined with an uncertainty of about 2% or better, depending on the wavelength considered, and 1%, respectively. Even if in this study we focused on particular batches of India ink and Intralipid, the reference values determined here represent a solid and useful starting point for preparing diffusive liquid phantoms with accurately defined optical properties. Furthermore, due to the ready availability, low cost, long-term stability and batch-to-batch reproducibility of these compounds, they provide a unique fundamental tool for the calibration and performance assessment of diffuse optical spectroscopy instrumentation intended to be used in laboratory or clinical environment. Finally, the collaborative work presented here demonstrates that the accuracy level attained in this work for optical properties of diffusive phantoms is reliable.

2.
Phys Med Biol ; 57(23): 7973-81, 2012 Dec 07.
Article En | MEDLINE | ID: mdl-23154664

A time-gated intensified CCD camera was applied for time-resolved imaging of light penetrating in an optically turbid medium. Spatial distributions of light penetration probability in the plane perpendicular to the axes of the source and the detector were determined at different source positions. Furthermore, visiting probability profiles of diffuse reflectance measurement were obtained by the convolution of the light penetration distributions recorded at different source positions. Experiments were carried out on homogeneous phantoms, more realistic two-layered tissue phantoms based on the human skull filled with Intralipid-ink solution and on cadavers. It was noted that the photons visiting probability profiles depend strongly on the source-detector separation, the delay between the laser pulse and the photons collection window and the complex tissue composition of the human head.


Optical Imaging/methods , Photons , Diffusion , Head , Humans , Light , Optical Imaging/instrumentation , Probability , Time Factors
3.
Phys Med Biol ; 54(3): 679-97, 2009 Feb 07.
Article En | MEDLINE | ID: mdl-19131674

Recently, a method for the estimation of speed distribution of particles moving in an optically turbid medium has been proposed. The method allows potentially absolute measurement of speed of the particles and can be applied in laser-Doppler perfusion measurements. However, the decomposition technique was limited to short source-detector separations for which the assumption that one photon is Doppler scattered not more than once is fulfilled. In the present paper we show a generalized decomposition technique in which photons can be scattered more than once. We show the theoretical background for decomposition in such a case. We apply a decomposition method for the analysis of laser-Doppler spectra obtained by Monte Carlo simulations. This analysis allows showing noise limits in which the technique can be effectively applied in analysis of measured spectra. We propose an approximated scattering model based on the assumption that for one photon consecutive Doppler scattering events occur on particles moving with the same speed, and we show that this approximation does not influence significantly the uncertainty of the resulting speed distribution. The proposed decomposition procedure is validated in measurements on a physical flow model. The decomposition procedure is also validated by analysis of spectra measured on a physical phantom using laser-Doppler flow meter (Oxford Optronix, UK). A diluted solution of milk was pumped through a tube fixed in an optically turbid material with speed varying from 0 mm s(-1) to 4 mm s(-1). We observed a linear relation between actual speed of milk solution and speed estimated from results of spectra decomposition.


Biopolymers/chemistry , Laser-Doppler Flowmetry/methods , Models, Biological , Models, Chemical , Nephelometry and Turbidimetry/methods , Animals , Biopolymers/analysis , Computer Simulation , Diffusion , Humans , Motion , Particle Size , Scattering, Radiation
4.
Opt Express ; 16(17): 13188-202, 2008 Aug 18.
Article En | MEDLINE | ID: mdl-18711557

We present an efficient Monte Carlo algorithm for simulation of time-resolved fluorescence in a layered turbid medium. It is based on the propagation of excitation and fluorescence photon bundles and the assumption of equal reduced scattering coefficients at the excitation and emission wavelengths. In addition to distributions of times of arrival of fluorescence photons at the detector, 3-D spatial generation probabilities were calculated. The algorithm was validated by comparison with the analytical solution of the diffusion equation for time-resolved fluorescence from a homogeneous semi-infinite turbid medium. It was applied to a two-layered model mimicking intra- and extracerebral compartments of the adult human head.


Algorithms , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Luminescent Measurements/methods , Microscopy, Fluorescence/methods , Nephelometry and Turbidimetry/methods , Spectrometry, Fluorescence/methods , Computer Simulation , Humans , Light , Models, Biological , Monte Carlo Method , Scattering, Radiation
5.
Phys Med Biol ; 51(22): 5737-51, 2006 Nov 21.
Article En | MEDLINE | ID: mdl-17068362

A method for measurement of distribution of speed of particles moving in an optically turbid medium is presented. The technique is based on decomposition of the laser-Doppler spectrum. The theoretical background is shown together with the results of Monte Carlo simulations, which were performed to validate the proposed method. The laser-Doppler spectra were obtained by Monte Carlo simulations for assumed uniform and Gaussian speed distributions of particles moving in the turbid medium. The Doppler shift probability distributions were calculated by Monte Carlo simulations for several anisotropy factors of the medium, assuming the Hanyey-Greenstein phase function. The results of the spectra decomposition show that the calculated speed distribution of moving particles match well the distribution assumed for Monte Carlo simulations. This result was obtained for the spectra simulated in optical conditions, in which the photon is scattered with the Doppler shift not more than once during its travel between the source and detector. Influence of multiple scattering of the photon is analysed and a perspective of spectrum decomposition under such conditions is considered. Potential applications and limitations of the method are discussed.


Blood Flow Velocity/physiology , Erythrocytes/physiology , Laser-Doppler Flowmetry/methods , Models, Cardiovascular , Nephelometry and Turbidimetry/methods , Cell Movement/physiology , Computer Simulation , Models, Statistical , Monte Carlo Method , Particle Size , Spectrum Analysis/methods
...