Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Radiat Prot Dosimetry ; 185(4): 409-413, 2019 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-30864671

RESUMEN

The International Commission on Radiological Protection has substantially reduced the recommended maximum annual eye lens dose for workers. Use of a dedicated eye dosemeter is one method for accurate dose monitoring. The main aim of this study was to yield recommendations for optimal placement of eye dosemeters to estimate the eye dose to interventional cardiology physicians and nurses. A phantom measurement was conducted to simulate typical interventional cardiology procedures. Considering eight X-ray tube angulations, the left side of the head position provide good estimates for physician, and the forehead position provide good estimates for nurse.


Asunto(s)
Exposición Profesional/análisis , Fantasmas de Imagen , Dosis de Radiación , Exposición a la Radiación/análisis , Monitoreo de Radiación/instrumentación , Radiología Intervencionista/métodos , Antropometría , Cardiología/métodos , Humanos , Cristalino/efectos de la radiación , Enfermeras y Enfermeros , Médicos , Dosímetros de Radiación , Monitoreo de Radiación/métodos , Protección Radiológica , Rayos X
2.
Acta Radiol ; 50(5): 474-81, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19353341

RESUMEN

Cardiac interventional radiology has lower risks than surgical procedures. This is despite the fact that radiation doses from cardiac intervention procedures are the highest of any commonly performed general X-ray examination. Maximum radiation skin doses (MSDs) should be determined to avoid radiation-associated skin injuries in patients undergoing cardiac intervention procedures. However, real-time evaluation of MSD is unavailable for many cardiac intervention procedures. This review describes methods of determining MSD during cardiac intervention procedures. Currently, in most cardiac intervention procedures, real-time measuring of MSD is not feasible. Thus, we recommend that physicians record the patient's total entrance skin dose, such as the dose at the interventional reference point when it can be monitored, in order to estimate MSD in intervention procedures.


Asunto(s)
Cardiopatías/terapia , Dosis de Radiación , Monitoreo de Radiación/métodos , Radiografía Intervencional/métodos , Cardiopatías/diagnóstico por imagen , Cardiopatías/cirugía , Humanos , Piel/efectos de la radiación
3.
Acta Radiol ; 50(2): 170-3, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19096953

RESUMEN

BACKGROUND: Currently, one or two dosimeters are used to monitor radiation exposure in most cardiac laboratories. In addition, several different formulas are used to convert exposure data into an effective dose (ED). PURPOSE: To clarify the effect of monitoring methods and formula selection on the estimated ED for physicians during percutaneous coronary interventions (PCIs). MATERIAL AND METHODS: The ED of physicians during cardiac catheterization was determined using an optically stimulated luminescence dosimeter (Luxel badge). Two Luxel badges were worn: one beneath a personal lead apron (0.35-mm lead equivalent) at the chest and one outside of the apron at the neck. RESULTS: The difference in the average ED of seven physicians was approximately fivefold (range 1.13-5.43 mSv/year) using the six different formulas in the clinical evaluation. The estimated physician ED differed markedly according to both the monitoring method and formula selected. CONCLUSION: ED estimation is dependent on both the monitoring method and the formula used. Therefore, it is important that comparisons among laboratories are based on the same monitoring method and same formula for calculating the ED.


Asunto(s)
Cateterismo Cardíaco , Exposición Profesional , Médicos , Dosis de Radiación , Monitoreo de Radiación/métodos , Radiografía Intervencional/efectos adversos , Humanos , Matemática , Protección Radiológica , Radiometría/métodos
4.
Acta Radiol ; 48(8): 846-50, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17924214

RESUMEN

BACKGROUND: A number of cases involving radiation-associated patient skin injury attributable to percutaneous coronary intervention (PCI) have been reported. Knowledge of the location and area of the patient's maximum skin dose (MSD) in PCI is necessary to reduce the risk of skin injury. PURPOSE: To determine the location and area of the MSD in PCI, and separately analyze the effects of different target vessels. MATERIAL AND METHODS: 197 consecutive PCI procedures were studied, and the location and area of the MSD were calculated by a skin-dose mapping software program: Caregraph. The target vessels of the PCI procedures were divided into four groups based on the American Heart Association (AHA) classification. RESULTS: The sites of the MSD for AHA #1-3, AHA #4, and AHA #11-15 were located mainly on the right back skin, the lower right or center back skin, and the upper back skin areas, respectively, whereas the MSD sites for the AHA #5-10 PCI were widely spread. The MSD area for the AHA #4 PCI was larger than that for the AHA #11-15 PCI (P<0.0001). CONCLUSION: Although the radiation associated with PCI can be widely spread and variable, we observed a tendency regarding the location and area of the MSD when we separately analyzed the data for different target vessels. We recommend the use of a smaller radiation field size and the elimination of overlapping fields during PCI.


Asunto(s)
Angiografía Coronaria , Monitoreo de Radiación/métodos , Piel/efectos de la radiación , Anciano , Angioplastia Coronaria con Balón , Fluoroscopía , Humanos , Persona de Mediana Edad , Dosis de Radiación , Radiografía Intervencional
5.
Acta Radiol ; 46(4): 386-90, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16134315

RESUMEN

PURPOSE: To determine the clinical feasibility of rapid-sequence phosphorus-31 magnetic resonance spectroscopy (31P-MRS) of the heart with cardiac patients using a 1.5T clinical MR system. MATERIAL AND METHODS: Twenty cardiac patients, i.e. dilated cardiomyopathy (DCM) 13 cases, hypertrophic cardiomyopathy (HCM) 3 cases, hypertensive heart diseases (HHD) 3 cases, and aortic regurgitation (AR) 1 case were examined using rapid cardiac 31P-MRS. Complete three-dimensional localization was performed using a two-dimensional phosphorus chemical-shift imaging sequence in combination with 30-mm axial slice-selective excitation. The rapid-sequence 31P-MRS procedure was phase encoded in arrays of 8 x 8 steps with an average of 4 acquisitions. The total examination time, including proton imaging and shimming, for the rapid cardiac 31P-MRS procedure, ranged from 10 to 15 min, depending on the heart rate. Student's t test was used to compare creatine phosphate (PCr)/adenosine triphosphate (ATP) ratios from the cardiac patients with those of the control subjects (n = 13). RESULTS: The myocardial PCr/ATP ratio obtained by rapid 31P-MRS was significantly lower (P < 0.001) in DCM patients (1.82 +/- 0.33, mean +/- SD), and in patients with global myocardial dysfunction (combined data for 20 patients: 1.89 +/- 0.32) than in normal volunteers (2.96 +/- 0.59). These results are similar to previous studies. CONCLUSION: Rapid-sequence 31P-MRS may be a valid diagnostic tool for patients with cardiac disease.


Asunto(s)
Técnicas de Diagnóstico Cardiovascular , Cardiopatías/diagnóstico , Espectroscopía de Resonancia Magnética/métodos , Miocardio/metabolismo , Adenosina Trifosfato/análisis , Adenosina Trifosfato/metabolismo , Electrocardiografía/métodos , Estudios de Factibilidad , Femenino , Cardiopatías/metabolismo , Humanos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Fosfocreatina/análisis , Fosfocreatina/metabolismo , Isótopos de Fósforo , Valores de Referencia , Sensibilidad y Especificidad , Factores de Tiempo
6.
Acta Radiol ; 46(8): 810-4, 2005 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16392605

RESUMEN

PURPOSE: To present a novel method for analyzing the voltage waveform from high-frequency X-ray generators for radiographic systems. MATERIAL AND METHODS: The output signal of the actual voltage across the tube of a high-frequency generator was measured using the built-in voltage sense taps that are used for voltage regulation feedback in X-ray generators. The output signal was stored in an analyzing recorder, and the waveforms were analyzed using FFT analysis. The FFT analysis of high-frequency generators consisted of obtaining the power spectrum, comparing the major frequency components in the tube voltage waveforms, and examining the intensity of each frequency component. RESULTS: FFT analysis enables an objective comparison of the complex tube voltage waveforms in high-frequency X-ray generators. FFT analysis detected the change in the X-ray tube voltage waveform that occurred when there were problems with the high-frequency generator. CONCLUSION: High-frequency X-ray generators are becoming the universal choice for radiographic systems. The X-ray tube voltage and its waveform are important features of an X-ray generator, and quality assurance (QA) is important, too. As a tool for engineers involved in the design and development of X-ray generators, we can see that our methods (FFT analysis) might have some value as a means of describing generator performance under varying conditions. Furthermore, since the X-ray tube voltage waveform of a high-frequency generator is complex, FFT analysis may be useful for QA of the waveform.


Asunto(s)
Electricidad , Análisis de Fourier , Radiografía/instrumentación , Radiometría/métodos , Algoritmos , Humanos , Garantía de la Calidad de Atención de Salud/métodos , Reproducibilidad de los Resultados
7.
Acta Radiol ; 45(1): 30-7, 2004 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15164776

RESUMEN

PURPOSE: To compare a 'standard' slow phosphorus-31 magnetic resonance spectroscopy (31P-MRS) sequence with two faster sequences in phantoms and healthy volunteers using a 1.5-T clinical system. MATERIAL AND METHODS: Complete 3D localization was performed using a 2D phosphorus chemical-shift imaging sequence in combination with 30-mm axial slice-selective excitation. Two 31P-MRS rapid sequences (RS8-4: 8 x 8 phase-encoding, with an average of 4 acquisitions, and RS16-1: 16 x 16 phase-encoding, 1 acquisition) were compared with the standard sequence (StdP: 16 x 16 phase-encoding, with an average of 8 acquisitions) in phantom and healthy volunteers. RESULTS: Acquisition time for the 31P-MRS procedure with StdP, RS8-4, and RS16-1 in the healthy volunteer studies ranged from 30 to 45, 3 to 5, and 3 to 5 minutes, respectively. Metabolite measurements of healthy volunteers obtained from 31P-MRS using RS8-4 correlated with values obtained using StdP (PCr r2=0.63, P<0.001; ATP r=0.41, P<0.01 and PCr/ATP ratio r2=0.25, P<0.05). There was no correlation between StdP and RS16-1 for either ATP or the PCr/ATP ratio (r2=0.03, P=0.60, and r2=0.11, p=0.26, respectively). Reproducibility (intensity of phosphorus signal) with RS16-1 was worse than that of RS8-4 or StdP. CONCLUSION: 31P-MRS using RS8-4 may be a valid diagnostic tool for patients with cardiac diseases.


Asunto(s)
Corazón/diagnóstico por imagen , Espectroscopía de Resonancia Magnética , Adulto , Humanos , Masculino , Fantasmas de Imagen , Fósforo , Cintigrafía , Factores de Tiempo
8.
Jpn J Thorac Cardiovasc Surg ; 49(5): 330-2, 2001 May.
Artículo en Inglés | MEDLINE | ID: mdl-11431956

RESUMEN

We present a case with asymptomatic mediastinal bronchial artery aneurysm at the origin of the left bronchial artery. This bronchial artery aneurysm was successfully treated with percutaneous transluminal coil embolization. Complete embolization of the feeding artery and tributaries from the aneurysm is the key to successful isolation of a large bronchial artery aneurysm from the circulation. Percutaneous transluminal embolization is one of the treatment options for a patient with asymptomatic, incidentally-identified bronchial artery aneurysm.


Asunto(s)
Aneurisma/terapia , Arterias Bronquiales , Embolización Terapéutica/métodos , Femenino , Humanos , Persona de Mediana Edad
9.
Comput Methods Programs Biomed ; 66(1): 105-10, 2001 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-11378231

RESUMEN

A few studies have been reported that CT cine viewing on the CRT is superior to film-based viewing of CT images (Seltzer et al., Radiology 197 (1994) 119; Bonaldi et al., Am. J. Roentgenol. 170 (1998) 373; Tillich et al., Am. J. Roentgenol. 169 (1997) 1611). The purpose of our study is to know how to use cine viewing of abdominal CT. Thirty CT studies on the abdomen with both precontrast and postcontrast images were examined. The suitable rate of cine viewing ranged from 1 to 6 frames per second according to the size, the contrast and the complexity of the anatomical structures, and the slice thickness. For small or complex structures, checking each image might be required to know the full detail of them. Positional sorting among multiphase images, which is followed by consecutive display of a precontrast image, postcontrast early and late phase images at one position and so on, is useful to see the dynamic pattern of enhancement of the anatomical structures. However, there was no significant difference between cine viewing and film-based viewing concerning both the detectability of the anatomical structures and the conspicuity of enhancement of the liver and the pancreas, so that cine viewing might be an alternative to film-based viewing for CT diagnosis of the abdomen.


Asunto(s)
Intensificación de Imagen Radiográfica/métodos , Radiografía Abdominal/métodos , Tomografía Computarizada por Rayos X/métodos , Abdomen/patología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad
10.
Tohoku J Exp Med ; 190(3): 169-76, 2000 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-10778800

RESUMEN

Quantitative digital subtraction angiography (DSA) image analysis based on densitometry is widely accepted and used. For the densitometoric DSA image analysis, it is required that there is a linear relationships between the pixel values on DSA images (DSA values) and contrast medium iodine concentration or the thickness of the vessels or the chambers filled with contrast material. We studied on relationship between the DSA value and iodine concentration especially in high iodine concentration. As for the relationship between DSA values and iodine concentration on the DSA images at low concentration, DSA phantom had a good linear relationship. However, the relationship at the high iodine concentration, DSA phantom sometimes lost this linear relationship. Our results suggested that it was necessary to identify relationship between DSA values and iodine concentration in each DSA system, especially in high iodine concentration setting, for densitometoric DSA image analysis.


Asunto(s)
Angiografía de Substracción Digital/métodos , Medios de Contraste , Yodo , Fantasmas de Imagen , Angiografía , Animales , Densitometría , Humanos , Procesamiento de Imagen Asistido por Computador
11.
Kyobu Geka ; 52(3): 243-6, 1999 Mar.
Artículo en Japonés | MEDLINE | ID: mdl-10097554

RESUMEN

A 13-year-old girl was admitted with a sudden onset of chest oppression. Mediastinal teratoma was suspected on chest X-ray and CT scan. A grade 2/6 systolic murmur was heard at the upper left sternal area and cardiac catheterization showed mild pulmonary stenosis. After resection of the tumor, the murmur disappeared and histopathological diagnosis was mature teratoma. This is a rare case report of pulmonary stenosis caused by mediastinal mature teratoma.


Asunto(s)
Neoplasias del Mediastino/complicaciones , Teratoma/complicaciones , Adolescente , Femenino , Humanos , Estenosis de la Válvula Pulmonar/etiología
12.
Jpn J Thorac Cardiovasc Surg ; 46(7): 643-6, 1998 Jul.
Artículo en Japonés | MEDLINE | ID: mdl-9750449

RESUMEN

We performed the coil embolization for 64-year-old male with patent ductus arteriosus and left ventricular dysfunction. We used "snare method" and "cross catheter technique" delivering one coil transvenously and one coil transarterially. Echocardiograms at 7 month after the procedure demonstrated complete occlusion of the ductus, though small shunt was detected at discharge.


Asunto(s)
Cateterismo Periférico/métodos , Conducto Arterioso Permeable/terapia , Embolización Terapéutica/métodos , Disfunción Ventricular Izquierda/complicaciones , Conducto Arterioso Permeable/complicaciones , Conducto Arterioso Permeable/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Ultrasonografía
13.
Nihon Igaku Hoshasen Gakkai Zasshi ; 57(9): 602-4, 1997 Aug.
Artículo en Japonés | MEDLINE | ID: mdl-9293759

RESUMEN

We have developed a cine display of postprocessed 3D MR images of the thoracic aorta. Maximum intensity projection (MIP) images of the thoracic aorta in each phase were reconstructed from consecutive 2D-cine MR data sets, and displayed in a cine loop. The postprocessed 3D MR images clearly showed the relationship between major cervical branches and aortic pathologies such as aneurysms, and cine display presented the flow pattern in the aorta. 3D-cine MR angiography seems to be useful for follow-up studies of thoracic aortic diseases especially in patients with renal dysfunction.


Asunto(s)
Aneurisma de la Aorta Torácica/diagnóstico , Disección Aórtica/diagnóstico , Imagen por Resonancia Cinemagnética/métodos , Adulto , Anciano , Humanos , Persona de Mediana Edad
14.
Ann Thorac Surg ; 63(1): 244-6, 1997 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8993282

RESUMEN

Aortic replacement was performed in a patient with acute type A aortic dissection originating from the descending thoracic aorta. Postoperatively, a persistent false lumen resulted in severe stenosis of the right renal artery. Percutaneous stent angioplasty improved renovascular hypertension and renal function. This procedure is useful for management of patients with branch complications of aortic dissection.


Asunto(s)
Angioplastia de Balón , Aneurisma de la Aorta Torácica/complicaciones , Disección Aórtica/complicaciones , Hipertensión Renovascular/etiología , Obstrucción de la Arteria Renal/etiología , Obstrucción de la Arteria Renal/terapia , Stents , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Femenino , Humanos , Hipertensión Renovascular/terapia , Persona de Mediana Edad , Radiografía , Obstrucción de la Arteria Renal/diagnóstico por imagen
16.
Nihon Igaku Hoshasen Gakkai Zasshi ; 56(13): 948-54, 1996 Nov.
Artículo en Japonés | MEDLINE | ID: mdl-8969058

RESUMEN

MR images of the brain were retrospectively reviewed in 13 patients with carbon monoxide (CO) poisoning to examine the relation between the MR findings and clinical course. The patients included 11 men and 2 women whose ages ranged from 6 to 88 years (mean, 38 years). Repeated MR studies of at most five times were performed on 9 patients. Lesions in the bilateral globus pallidi were found in 5 cases showing hyperintensity on T2-weighted images (T2WI) and iso-to hypointensity on T1-weighted images (T1WI). The patients with only pallidi lesions clinically recovered well. Hyperintense white matter lesions were recognized on T2WI in 8 patients, including all 5 with delayed encephalopathy. Sequential studies generally showed a tendency of regression of these hyperintense lesions with improvement of symptoms, indicative of reversible demyelination as documented in the pathological literature. One patient with poor prognosis revealed white matter lesions, that were hyperintense on T2WI and very hypointense on T1WI, which may represent irreversible change. Thus, clinical course seems to be closely related with white matter lesions, but not with pallidi lesions. In cases of CO intoxication, therefore, MR study provides valuable information on patients' clinical prognoses.


Asunto(s)
Encéfalo/patología , Intoxicación por Monóxido de Carbono/diagnóstico , Imagen por Resonancia Magnética , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
17.
J Am Coll Cardiol ; 27(1): 30-7, 1996 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8522707

RESUMEN

OBJECTIVES: This study sought to investigate the effect of coronary angioplasty on chronic hypoperfusion-induced endothelial dysfunction in patients with coronary heart disease. BACKGROUND: The endothelium is an important component for organ flow regulation. Ischemia with or without reperfusion is known to cause endothelial dysfunction. We tested the hypothesis that chronic hypoperfusion impairs endothelial function in the angiographically normal coronary artery segment distal to stenosis and that the impairment by chronic hypoperfusion is reduced by coronary angioplasty. METHODS: In 13 patients with stable angina pectoris, substance P (10, 30 and 100 pmol) and nitroglycerin (200 micrograms) were sequentially infused into the coronary artery in a cumulative manner on the day after coronary angioplasty. In 10 of these patients, vascular responses to these agents were again investigated 3 months after angioplasty. Changes in vascular diameter were evaluated in vessels located proximal and distal to the target lesion, both of which were angiographically normal, by performing computer-assisted quantitative coronary angiography. In five patients, the transstenotic pressure gradient was also measured with a pressure sensor-mounted guide wire before angioplasty. RESULTS: On the day after angioplasty, the magnitude of dilation by substance P in distal segments was significantly less than that in proximal segments and inversely correlated with the transstenotic pressure gradient (p < 0.05) and lesion stenosis (p < 0.05). There was no difference in nitroglycerin-induced vasodilation between the two vessel segment groups. Three months later, the impaired response to substance P in the distal segment was restored to normal. CONCLUSIONS: We conclude that chronic hypoperfusion impairs endothelium-dependent dilation of coronary artery distal to critical stenosis in patients with ischemic heart disease and that coronary angioplasty ameliorates the endothelial dysfunction within 3 months.


Asunto(s)
Angina de Pecho/fisiopatología , Angina de Pecho/terapia , Angioplastia Coronaria con Balón , Endotelio Vascular/fisiopatología , Anciano , Angina de Pecho/diagnóstico por imagen , Angiografía Coronaria , Vasos Coronarios/efectos de los fármacos , Relación Dosis-Respuesta a Droga , Estudios de Seguimiento , Humanos , Inyecciones Intraarteriales , Masculino , Persona de Mediana Edad , Nitroglicerina/administración & dosificación , Variaciones Dependientes del Observador , Estudios Prospectivos , Análisis de Regresión , Factores de Riesgo , Volumen Sistólico/fisiología , Sustancia P/administración & dosificación , Vasodilatadores/administración & dosificación
18.
Tohoku J Exp Med ; 175(4): 219-23, 1995 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-7570580

RESUMEN

A simple maneuver in intraarterial digital subtraction angiography (DSA) is proposed to improve the images of left internal thoracic artery bypass grafts (LITAGs). A contrast flush in the left subclavian artery, using a catheter that had been percutaneously introduced from the left brachial artery, was carried out in 14 patients with multiple coronary-aorta bypass grafts (CABGs) after aortic DSA. The side-hole portion of the catheter tip was positioned in the proximal left subclavian artery as the coiled portion remained in the aortic arch. Nonionic contrast medium (350 mg/ml of iodine) was injected with an automatic injector in a volume of 6-8 ml and at a flow rate of 3-4 ml/sec. Left subclavian arterial flush DSA delineated the LITAGs excellently in 11, well in 3, and fairly or poorly in none of the 14 cases. There were no complications in any of these cases. A supplemental contrast flush of the left subclavian artery with a pigtail catheter following aortic DSA improves the diagnosis of multiple CABG patency.


Asunto(s)
Angiografía de Substracción Digital/estadística & datos numéricos , Puente de Arteria Coronaria , Estudios de Seguimiento , Anciano , Cateterismo , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad
19.
Nihon Igaku Hoshasen Gakkai Zasshi ; 54(8): 751-60, 1994 Jul 25.
Artículo en Japonés | MEDLINE | ID: mdl-8072865

RESUMEN

CT and MR imaging findings of 57 sphenoidal masses were retrospectively reviewed to assess the possibility of differential diagnosis between them. Various kinds of masses such as pituitary adenoma, epipharyngeal cancer, mucocele, chordoma, chondroma, chondrosarcoma, distant metastasis, multiple myeloma, fibrous dysplasia, craniopharyngioma, hemangiopericytoma, giant cell tumor, primary sphenoidal cancer, malignant melanoma, leukemia, histiocytosis X, and giant cell tumor were included in this series. CT scanning was performed in all cases, while MR images were obtained in 48 cases using a spin-echo pulse sequence. The relative density of the masses, bony changes and calcification were evaluated on CT, and on MR images, signal intensity of the masses relative to the normal gray matter, contrast enhancement and extension/contour were evaluated. Although no single feature appeared to be specific to the masses, detection of calcification on CT, identification of the normal pituitary gland as deformed or displaced on T1-weighted images, signal intensity on T2-weighted images, and extension of the masses seemed to be useful and should be examined in terms of their ability to assist in differential diagnosis. Finally, accommodative classification of sphenoidal masses primarily based on presumed origin or mode of extension was attempted.


Asunto(s)
Neoplasias de los Senos Paranasales/diagnóstico , Seno Esfenoidal , Adolescente , Adulto , Anciano , Niño , Preescolar , Diagnóstico Diferencial , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Neoplasias de los Senos Paranasales/diagnóstico por imagen , Neoplasias Hipofisarias/diagnóstico , Estudios Retrospectivos , Seno Esfenoidal/patología , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...