Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 5 de 5
1.
Updates Surg ; 2024 Mar 20.
Article En | MEDLINE | ID: mdl-38507177

Transduodenal Ampullectomy (TA) is a procedure for resecting low-malignancy ampullary tumors, with postoperative fistula as a notable complication. This study aims to clarify the indications for TA, outline the surgical robotic technique, and emphasize the importance of comprehensive complication management alongside the surgical approach. This multimedia article provides a detailed exposition of the robotic TA surgical technique, including the most important steps involved in exposing and reimplanting biliary and pancreatic ducts. The procedure encompasses the mobilization of the hepatic flexure of the colon, an extensive Kocher maneuver for duodenal mobilization, and ampulla exposure through a duodenal incision. Employing retraction loop sutures enhances surgical field visibility. Reconstruction involves securing pancreatic and biliary ducts to the duodenal mucosa, each tutored with a silicon catheter, and suturing for ampullectomy completion. The total operative time was 380 min. Final histopathology disclosed high-grade dysplasia with an isolated focus of adenocarcinoma (pT1), accompanied by clear resection margins. A postoperative duodenal fistula occurred, managed successfully through conservative treatment, utilizing subcutaneous drainage. Despite accurate robotic TA execution, complications may arise. This study underscores the importance of a comprehensive approach, incorporating meticulous surgical technique and effective complication management, to optimize patient outcomes.

2.
Ann Surg Oncol ; 31(5): 3084-3085, 2024 May.
Article En | MEDLINE | ID: mdl-38315334

BACKGROUND: Perihilar cholangiocarcinoma is a challenging technique to be performed by minimally invasive approach being the type III among the most complex procedure. Nowadays, the robotic approach is gaining increasing interest among the surgical community, and more and more series describing robotic liver resection have been reported. However, few cases of minimally invasive Bismuth type IIIA cholangiocarcinoma have been reported. Robotic approach allows for a better dissection and suture thanks to the flexible and precise instruments movements, overcoming some of the limitations of the laparoscopic technique. Therefore, robotic technique can facilitate some of the critical steps of a technically demanding procedure, such as the extended right hepatectomy for perihilar cholangiocarcinoma Bismuth IIIA type. METHODS: In this multimedia video we describe, for the first time in the literature, a full robotic surgical step-by-step technique with some tips and tricks for treating a perihilar cholangiocarcinoma Bismuth IIIA type, performing a radical extended right hemihepatectomy, including segment I combined with regional lymphadenectomy anf left bile duct reconstruction. A 55-year-old woman with obstructive jaundice (10 mg/dl) was referred to our center. The endobiliary brushing confirmed adenocarcinoma, and MRI/CT showed a focal perihilar lesion of 2 cm, including the main biliary duct bifurcation and extending up to the right duct (Bismuth Type IIIA hilar cholangiocarcinoma). After endoscopic biliary stents placement and 6 weeks after right portal vein embolization, the future liver remnant, including segments II and III, reached an enough hypertrophy volume with a ratio of 30%. A right hemihepatectomy with caudate lobe, including standard standard lymphadenectomy and left biliary duct reconstruction was performed. RESULTS: The operation lasted 670 min with an estimated blood loss of 350 ml. Postoperative pathological examination revealed a moderately differentiated adenocarcinoma pT1N0 with 15 retrieved nodes and free margins. The patient experienced a type A biliary fistula and was discharged on the 21st postoperative day without abdominal drainage. CONCLUSIONS: Through the tips and tricks presented in this multimedia article, we show the advantages of the robotic approach for performing correctly one of the most complex surgeries.1-7.


Bile Duct Neoplasms , Cholangiocarcinoma , Klatskin Tumor , Robotic Surgical Procedures , Female , Humans , Middle Aged , Bile Duct Neoplasms/surgery , Bile Duct Neoplasms/pathology , Bile Ducts, Intrahepatic/pathology , Bismuth , Cholangiocarcinoma/surgery , Hepatectomy/methods , Klatskin Tumor/surgery , Klatskin Tumor/pathology , Robotic Surgical Procedures/methods
4.
Ann Surg Oncol ; 31(3): 1916-1918, 2024 Mar.
Article En | MEDLINE | ID: mdl-38071705

INTRODUCTION: The robotic approach is attracting increasing interest among the surgical community, and more and more series describing robotic pancreatoduodenectomy have been reported. Thus, surgeons performing robotic pancreatoduodenectomy should be confident with this critical step's potential scenarios. MATERIALS AND METHODS: According to Yosuke et al., there are three different levels of mesopancreas dissection. We describe the main steps for a safe mesopancreas dissection by robotic approach. RESULTS: This multimedia article provides, for the first time in literature, a comprehensive step-by-step overview of the mesopancreas dissection during robotic pancreatoduodenectomy (PD) and its three different levels according to tumor type. CONCLUSIONS: Through the tips and indications presented in this multimedia article, we aim to familiarize surgeons with the mesopancreas dissections levels according to type of malignancy and vascular anatomy.


Pancreatic Neoplasms , Robotic Surgical Procedures , Surgeons , Humans , Pancreatic Neoplasms/surgery , Dissection , Pancreaticoduodenectomy
5.
BMC Surg ; 18(Suppl 1): 19, 2019 Apr 24.
Article En | MEDLINE | ID: mdl-31074396

BACKGROUND: Robotic thyroidectomy by transaxillary approach (RATS) is regarded as a feasible and safe alternative procedure in selected patients with benign disease or thyroid cancer of low risk, facilitating thyroidectomy with respect to conventional endoscopic approach and offering improved cosmetic results. The Da Vinci Xi surgical system (Intuitive Surgical, Sunnyvale, CA, USA) presents technical advantages over its previous generations, including overhead docking, more compact robotic arms, extended range of motion, and ability for camera to be docked in any arm. This construct supports dissection in smaller spaces with less arm interference and improved view. We present an initial experience of RATS on DVSS Xi in an academic Centre in Italy. METHODS: We conducted a prospective observational study, involving patients with thyroid disease and treated between April 2016 and January 2018. A modified thyroidectomy retractor (Modena retractor, CEATEC Medizintechnik, Germany) was used to lift a musculocutaneous flap and operate gasless. Instrument placement was recorded for each procedure. Each procedure description was broken down into three phases, creation of working space, machine docking with instrument positioning and endoscopic operating technique. Duration of cases was recorded. Patients selected were young women, BMI < 30, thyroid nodule < 5 cm, cytology TIR2 to TIR4 (TIR4:only nodules < 1 cm diameter). RESULTS: Twelve RATS were performed within the learning curve for the robotic technique, 10 lobectomies and 2 total thyroidectomies. No patients required reintervention. Mean duration of surgery was 198.9 min for lobectomy and 210 for thyroidectomy. The same surgical team performed all procedures. No patients presented surgery-related complications, mean stay was 3 days. Decrease in operating time was observed after 8 cases along with more precise preparation of working space. Four arms were used in the first 10 procedures then only three. No recurrent laryngeal nerve dysfunction, no seroma or haematoma were recorded. One patient had transient hypocalcaemia after total thyroidectomy. CONCLUSIONS: Since the early phases of a preliminary experience RATS appeared a safe alternative to open thyroidectomy. Uptake of technique was quick on Xi platform with few technical tweaks over techniques described for Si machines. Careful patient selection is crucial. TRIAL REGISTRATION: Retrospectively registered on 20 july 2018 . TRIAL REGISTRATION NUMBER: researchregistry4272. The Research Registry: https://www.researchregistry.com/browse-the-registry#home/registrationdetails/5b517f08dbc2045aefd7f9b4/.


Robotic Surgical Procedures/methods , Thyroid Neoplasms/surgery , Thyroidectomy/methods , Adult , Dissection , Endoscopy/methods , Female , Humans , Learning Curve , Middle Aged , Operative Time , Prospective Studies , Thyroid Nodule/surgery
...