Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Food Chem X ; 2: 100032, 2019 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-31432016

RESUMEN

The physico-elemental profiles of commercially attained and roasted organic coffee beans from Ethiopia, Colombia, Honduras, and Mexico were compared using light microscopy, X-ray micro-computed tomography, and external beam particle induced X-ray emission. External beam PIXE analysis detected P, S, Cl, K, Ca, Ti, Mn, Fe, Cu, Zn, Br, Rb, and Sr in samples. Linear discriminant analysis showed that there was no strong association between elemental data and production region, whilst a heatmap combined with hierarchical clustering showed that soil-plant physico-chemical properties may influence regional elemental signatures. Physical trait data showed that Mexican coffee beans weighed significantly more than beans from other regions, whilst Honduras beans had the highest width. X-ray micro-computed tomography qualitative data showed heterogeneous microstructural features within and between beans representing different regions. In conclusion, such multi-dimensional analysis may present a promising tool in assessing the nutritional content and qualitative characteristics of food products such as coffee.

2.
Gigascience ; 8(3)2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30534956

RESUMEN

BACKGROUND: Taphonomic and palaeoecologic studies of obrution beds often employ conventional methods of investigation such as physical removal and extraction of fossils from their host rock (matrix) by mechanical preparation. This often-destructive method is not suitable for studying mold fossils, which are voids left in host rocks due to dissolution of the original organism in post-depositional processes. FINDINGS: Microcomputed tomography (µCT) scan data of 24 fossiliferous rock samples revealed thousands of Paleozoic echinoderms. Digitally "stitching" together individually µCT scanned rock samples within three-dimensional (3D) space allows for quantifiable taphonomic data on a fossil echinoderm-rich obrution deposit from the Devonian (Emsian) of South Africa. Here, we provide a brief step-by-step guide on creating, segmenting, and ultimately combining sections of richly fossiliferous beds to create virtual models suited for the quantitative and qualitative taphonomic analyses of fossil invertebrate assemblages. CONCLUSIONS: Visualizing the internal features of fossiliferous beds in 3D is an invaluable taphonomic tool for analyzing delicate fossils, accounting for all specimens irrespective of their preservation stages and with minimal damage. This technique is particularly useful for analyzing fossiliferous deposits with mold fossils that prove to be difficult to study with traditional methods, because the method relies on the large density contrast between the mold and host rock.


Asunto(s)
Fósiles , Sedimentos Geológicos , Paleontología , Microtomografía por Rayos X , Animales , Equinodermos , Geografía , Procesamiento de Imagen Asistido por Computador , Sudáfrica
3.
MethodsX ; 5: 1336-1345, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30406023

RESUMEN

X-ray micro computed tomography (microCT) can be applied to analyse powder feedstock used in additive manufacturing. In this paper, we demonstrate a dedicated workflow for this analysis method, specifically for Ti6Al4V powder typically used in commercial powder bed fusion (PBF) additive manufacturing (AM) systems. The methodology presented includes sample size requirements, scan conditions and settings, reconstruction and image analysis procedures. We envisage this method will support standardization in powder analysis in the additive manufacturing community. This is aimed at ultimately improving the quality of additively manufactured parts, through the identification of impurities and defects in powders. •MicroCT analysis of metal powders for additive manufacturing•Method describes a standard workflow simplifying usage of the technique•Sample requirements and image analysis workflow is described.

4.
MethodsX ; 5: 1102-1110, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30271722

RESUMEN

MicroCT is a well-established technique that is used to analyze the interior of objects non-destructively, and it is especially useful for void or porosity analysis. Besides its widespread use, few standards exist and none for additive manufacturing as yet. This is due to the inherent differences in part design, sizes and geometries, which results in different scan resolutions and qualities. This makes direct comparison between different scans of additively manufactured parts almost impossible. In addition, different image analysis methodologies can produce different results. In this method paper, we present a simplified 10 mm cube-shaped coupon sample as a standard size for detailed analysis of porosity using microCT, and a simplified workflow for obtaining porosity information. The aim is to be able to obtain directly comparable porosity information from different samples from the same AM system and even from different AM systems, and to potentially correlate detailed morphologies of the pores or voids with improper process parameters. The method is applied to two examples of different characteristic types of voids in AM: sub-surface lack of fusion due to improper contour scanning, and tree-like pores growing in the build direction. This standardized method demonstrates the capability for microCT to not only quantify porosity, but also identify void types which can be used to improve AM process optimization.

5.
MethodsX ; 5: 1111-1116, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30294558

RESUMEN

The use of microCT of 10 mm coupon samples produced by AM has the potential to provide useful information of mean density and detailed porosity information of the interior of the samples. In addition, the same scan data can be used to provide surface roughness analysis of the as-built surfaces of the same coupon samples. This can be used to compare process parameters or new materials. While surface roughness is traditionally done using tactile probes or with non-contact interferometric techniques, the complex surfaces in AM are sometimes difficult to access and may be very rough, with undercuts and may be difficult to accurately measure using traditional techniques which are meant for smoother surfaces. This standard workflow demonstrates on a coupon sample how to acquire surface roughness results, and compares the results from roughly the same area of the same sample with tactile probe results. The same principle can be applied to more complex parts, keeping in mind the resolution limit vs sample size of microCT.

6.
MethodsX ; 5: 1117-1123, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30294559

RESUMEN

MicroCT is best known for its ability to detect and quantify porosity or defects, and to visualize its 3D distribution. However, it is also possible to obtain accurate volumetric measurements from parts - this can be used in combination with the part mass to provide a good measure of its average density. The advantage of this density-measurement method is the ability to combine the density measurement with visualization and other microCT analyses of the same sample. These other analyses may include detailed porosity or void analysis (size and distribution) and roughness assessment, obtainable with the same scan data. Simple imaging of the interior of the sample allows the detection of unconsolidated powder, open porosity to the surface or the presence of inclusions. The CT density method presented here makes use of a 10 mm cube sample and a simple data analysis workflow, facilitating standardization of the method. A laboratory microCT scanner is required at 15 µm voxel size, suitable software to allow sub-voxel precise edge determination of the scanned sample and hence an accurate total volume measurement, and a scale with accuracy to 3 digits. •MicroCT-based mean density measurement method.•Accurate volume measurement and scale mass.•10 mm cube sample allows standardization and automation of workflow.

7.
Gigascience ; 7(1): 1-8, 2018 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-29267887

RESUMEN

This Data Note provides data from an experimental campaign to analyse the detailed internal and external morphology and mechanical properties of venomous snake fangs. The aim of the experimental campaign was to investigate the evolutionary development of 3 fang phenotypes and investigate their mechanical behaviour. The study involved the use of load simulations to compare maximum Von Mises stress values when a load is applied to the tip of the fang. The conclusions of this study have been published elsewhere, but in this data note we extend the analysis, providing morphological comparisons including details such as curvature comparisons, thickness, etc. Physical compression results of individual fangs, though reported in the original paper, were also extended here by calculating the effective elastic modulus of the entire snake fang structure including internal cavities for the first time. This elastic modulus of the entire fang is significantly lower than the locally measured values previously reported from indentation experiments, highlighting the possibility that the elastic modulus is higher on the surface than in the rest of the material. The micro-computed tomography (microCT) data are presented both in image stacks and in the form of STL files, which simplifies the handling of the data and allows its re-use for future morphological studies. These fangs might also serve as bio-inspiration for future hypodermic needles.


Asunto(s)
Evolución Biológica , Agujas , Venenos de Serpiente/metabolismo , Serpientes/anatomía & histología , Diente/anatomía & histología , Animales , Fenómenos Biomecánicos , Materiales Biomiméticos , Módulo de Elasticidad , Diseño de Equipo , Fenotipo , Serpientes/fisiología , Estrés Mecánico , Diente/fisiología , Diente/ultraestructura , Microtomografía por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...