Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Front Digit Health ; 6: 1403457, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39184339

RESUMEN

Cardiovascular diseases (CVDs) are a global burden that requires attention. For the detection and diagnosis of CVDs, the 12-lead ECG is a key tool. With technological advancements, ECG devices are becoming smaller and available for home use. Most of these devices contain a limited number of leads and are aimed to detect atrial fibrillation (AF). To investigate whether a four-electrode arrangement could provide enough information to diagnose other CVDs, further research is necessary. At the University Medical Center Utrecht in a multidisciplinary team, we developed the miniECG, a four-electrode ECG handheld system for scientific research in clinical environments (TRL6). This paper describes the process followed during the development of the miniECG. From assembling a multidisciplinary team, which includes engineers, cardiologists, and clinical physicians to the contribution of team members in the design input, design, and testing for safety and functionality of the device. Finally, we detail how the development process was composed by iterative design steps based on user input and intended use evolution. The miniECG is a device compliant for scientific research with patients within Dutch Medical Centers. We believe that hospital-based development led to a streamlined process, which could be applied for the design and development of other technologies used for scientific research in clinical environments.

2.
Phys Med Biol ; 69(17)2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39084657

RESUMEN

Objective.A robotic needle implant device for MR-guided high-dose-rate (HDR) prostate brachytherapy was developed. This study aimed to assess the feasibility and spatial accuracy of HDR brachytherapy using the robotic device, for a single intraprostatic target point.Approach.Five patients were treated from November 2019-June 2022 with the robot. The robot fits a 1.5 T MR scanner and the needle can be shifted and angulated. An intraprocedural MR scan was fused with the diagnostic MR and one preplanned needle position was selected for robotic insertion. The needle entry point and angles were set for a needle tip target point within the intraprostatic target volume. The needle was tapped stepwise towards the target point pneumatically. Final needle position was verified with MR, followed by plan optimization and dose delivery. Any remaining planned needles were inserted manually. Needle tip to geometrical target error (NTG-error) was defined as the deviation of the actual tip position relative to the predefined geometric target point, using MR-coordinates. Needle tip to treatment target error (NTT-error) was defined as the deviation of the actual tip position relative to the treatment target point, using fused MR-images pre- and post-needle implantation taking into account prostate deformation. Difference between NTT-error and NTG-error and fiducial marker shifts indicated prostate movement. For determining prostate deformation, the Jaccard index and prostate volumes were assessed.Main results.The robotic device was able to tap the needle to the planned depth for all patients. Mean robotic procedure duration was 142 min. NTG-error was 3.2 (range 1.1-6.7) mm and NTT-error 4.5 (range 2.6-9.6) mm. Marker displacements were smaller than 3 mm. No treatment-related acute toxicity was reported. Feasibility of needle placement within the prostate was considered adequate.Significance.MR-guided robotic needle insertion is feasible with a mean geometric accuracy of 3.2 mm and <3 mm prostate movement.


Asunto(s)
Braquiterapia , Imagen por Resonancia Magnética , Agujas , Neoplasias de la Próstata , Dosificación Radioterapéutica , Radioterapia Guiada por Imagen , Robótica , Masculino , Humanos , Braquiterapia/instrumentación , Braquiterapia/métodos , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/diagnóstico por imagen , Robótica/instrumentación , Radioterapia Guiada por Imagen/métodos , Radioterapia Guiada por Imagen/instrumentación , Prueba de Estudio Conceptual , Dosis de Radiación , Próstata/efectos de la radiación , Próstata/diagnóstico por imagen , Procedimientos Quirúrgicos Robotizados/instrumentación , Procedimientos Quirúrgicos Robotizados/métodos
3.
Brain ; 147(8): 2842-2853, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38662766

RESUMEN

Amyotrophic lateral sclerosis is a devastating neurodegenerative disease, characterized by loss of central and peripheral motor neurons. Although the disease is clinically and genetically heterogeneous, axonal hyperexcitability is a commonly observed feature that has been suggested to reflect an early pathophysiological step linked to the neurodegenerative cascade. Therefore, it is important to clarify the mechanisms causing axonal hyperexcitability and how these relate to the clinical characteristics of patients. Measures derived directly from a nerve excitability recording are frequently used as study end points, although their biophysical basis is difficult to deduce. Mathematical models can aid in the interpretation but are reliable only when applied to group-averaged recordings. Consequently, model estimates of membrane properties cannot be compared with clinical characteristics or treatment effects in individual patients, posing a considerable limitation in heterogeneous diseases, such as amyotrophic lateral sclerosis. To address these challenges, we revisited nerve excitability using a new pattern analysis-based approach (principal component analysis). We evaluated disease-specific patterns of excitability changes and established their biophysical origins. Based on the observed patterns, we developed new compound measures of excitability that facilitate the implementation of this approach in clinical settings. We found that excitability changes in amyotrophic lateral sclerosis patients (n = 161, median disease duration = 11 months) were characterized by four unique patterns compared with controls (n = 50, age and sex matched). These four patterns were best explained by changes in resting membrane potential (modulated by Na+/K+ currents), slow potassium and sodium currents (modulated by their gating kinetics) and refractory properties of the nerve. Consequently, we were able to show that altered gating of slow potassium channels was associated with, and predictive of, the rate of progression of the disease on the amyotrophic lateral sclerosis functional rating scale. Based on these findings, we designed four composite measures that capture these properties to facilitate implementation outside this study. Our findings demonstrate that changes in nerve excitability in patients with amyotrophic lateral sclerosis are dominated by four distinct patterns, each with a distinct biophysical origin. Based on this new approach, we provide evidence that altered slow potassium-channel function might play a role in the rate of disease progression. The magnitudes of these patterns, quantified using a similar approach or our new composite measures, have potential as efficient measures to study membrane properties directly in amyotrophic lateral sclerosis patients, and thus aid prognostic stratification and trial design.


Asunto(s)
Esclerosis Amiotrófica Lateral , Neuronas Motoras , Esclerosis Amiotrófica Lateral/fisiopatología , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Neuronas Motoras/fisiología , Adulto , Potenciales de Acción/fisiología , Análisis de Componente Principal , Axones/fisiología , Potenciales de la Membrana/fisiología
4.
Muscle Nerve ; 65(3): 317-325, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34854491

RESUMEN

INTRODUCTION/AIMS: Progressive axonal loss in multifocal motor neuropathy (MMN) is often assessed with nerve conduction studies (NCS), by recording maximum compound muscle action potentials (CMAPs). However, reinnervation maintains the CMAP amplitude until a significant portion of the motor unit (MU) pool is lost. Therefore, we performed more informative CMAP scans to study MU characteristics in a large cohort of patients with MMN. METHODS: We derived the maximum CMAP amplitude (CMAPmax ), an MU number estimate (MUNE), and the largest MU amplitude stimulus current required to elicit 5%, 50%, and 95% of CMAPmax (S5, S50, S95) and relative ranges ([S95 - S5] × 100 / S50) from the scans. These metrics were compared with clinical, laboratory, and NCS results. RESULTS: Forty MMN patients and 24 healthy controls were included in the study. CMAPmax and MUNE were reduced in MMN patients (both P < .001). Largest MU amplitude as a percentage of CMAPmax was increased in MMN patients (P < .001). Disease duration and treatment duration were not associated with MUNE. Relative range was larger in patients with anti-GM1 antibodies than in those without anti-GM1 antibodies (P = .016) and controls (P < .001). The largest MU amplitudes were larger in patients without anti-GM1 antibodies than in patients with anti-GM1 antibodies (P = .037) and controls (P = .044). DISCUSSION: We found that MU loss is common in MMN and accompanied by enlarged MUs. Presence of anti-GM1 antibodies was associated with increased relative range of MU thresholds and reduction in largest MU amplitude. Our findings indicate that CMAP scans complement routine NCS, and may have potential for practical monitoring of treatment efficacy and disease progression.


Asunto(s)
Polineuropatías , Potenciales de Acción/fisiología , Estudios de Cohortes , Progresión de la Enfermedad , Humanos , Conducción Nerviosa/fisiología , Polineuropatías/diagnóstico por imagen
5.
Clin Neurophysiol ; 132(2): 323-331, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33450554

RESUMEN

OBJECTIVE: To investigate the impact of stimulus duration on motor unit (MU) thresholds and alternation within compound muscle action potential (CMAP) scans. METHODS: The stimulus duration (0.1, 0.2, 0.6, and 1.0 ms) in thenar CMAP scans and individual MUs of 14 healthy subjects was systematically varied. We quantified variability of individual MU's thresholds by relative spread (RS), MU thresholds by stimulus currents required to elicit target CMAPs of 5% (S5), 50% (S50) and 95% (S95) of the maximum CMAP, and relative range (RR) by 100*[S95-S5]/S50. We further assessed the strength-duration time constant (SDTC). Experimental observations were subsequently simulated to quantify alternation. RESULTS: RS, unaffected by stimulus duration, was 1.65% averaged over all recordings. RR increased for longer stimulus duration (11.4% per ms, p < 0.001). SDTC shortened with higher target CMAPs (0.007 ms per 10% CMAP, p < 0.001). Experiments and simulations supported that this may underlie the increased RR. A short compared to long stimulus duration recruited relative more MUs at S50 (more alternation) than at the tails (less alternation). CONCLUSIONS: The stimulus duration significantly affects MU threshold distribution and alternation within CMAP scans. SIGNIFICANCE: Stimulation settings can be further optimized and their standardization is preferred when using CMAP scans for monitoring neuromuscular diseases.


Asunto(s)
Potenciales de Acción , Fibras Musculares Esqueléticas/fisiología , Estimulación Eléctrica Transcutánea del Nervio/métodos , Adulto , Electromiografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Contracción Muscular , Tiempo
6.
Clin Neurophysiol ; 131(11): 2641-2650, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32947198

RESUMEN

OBJECTIVE: To assess excitability differences between motor and sensory axons of affected nerves in patients with multifocal motor neuropathy (MMN). METHODS: We performed motor and sensory excitability tests in affected median nerves of 20 MMN patients and in 20 age-matched normal subjects. CMAPs were recorded from the thenar and SNAPs from the 3rd digit. Clinical tests included assessment of muscle strength, two-point discrimination and joint position. RESULTS: All MMN patients had weakness of the thenar muscle and normal sensory tests. Motor excitability testing in MMN showed an increased threshold for a 50% CMAP, increased rheobase, decreased stimulus-response slope, fanning-out of threshold electrotonus, decreased resting I/V slope, shortened refractory period, and more pronounced superexcitability. Sensory excitability testing in MMN revealed decreased accommodation half-time and S2-accommodation and less pronounced subexcitability. Mathematical modeling indicated increased Barrett-Barrett conductance for motor fibers and increase in internodal fast potassium conductance for sensory fibers. CONCLUSIONS: Excitability findings in MMN suggest myelin sheath or paranodal seal involvement in motor fibers and, possibly, paranodal detachment in sensory fibers. SIGNIFICANCE: Excitability properties of affected nerves in MMN differ between motor and sensory nerve fibers.


Asunto(s)
Potenciales de Acción/fisiología , Axones/fisiología , Neuronas Motoras/fisiología , Conducción Nerviosa/fisiología , Polineuropatías/fisiopatología , Células Receptoras Sensoriales/fisiología , Adulto , Anciano , Estimulación Eléctrica , Femenino , Humanos , Masculino , Persona de Mediana Edad
7.
Muscle Nerve ; 60(3): 279-285, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31241195

RESUMEN

INTRODUCTION: The aim of this study was to find the best method of warming the median nerve before excitability testing to a standard temperature. METHODS: In 5 healthy subjects, the forearm and hand were warmed for 1 h to 37°C by infrared lamp, water blanket, or water bath. Recordings were performed before and during warming every 10 min. Excitability indices were fitted by exponential relations, thereby calculating the time needed to reach 95% of their asymptotic end value. RESULTS: Distal motor latency, refractory period, and superexcitability at 10 ms changed exponentially with time. Warming by water bath took the shortest time (24 min); this was followed by warming by infrared lamp (34 min) and water blanket (35 min). CONCLUSIONS: Warming by water bath is the quickest way. The other methods took only moderately more time. Future studies need to specify both warming method and warming time before excitability testing. Muscle Nerve, 2019.


Asunto(s)
Hipotermia/fisiopatología , Nervio Mediano/fisiopatología , Piel/fisiopatología , Temperatura , Adulto , Femenino , Humanos , Masculino , Tejido Nervioso/fisiopatología , Factores de Tiempo
8.
Clin Neurophysiol ; 129(8): 1634-1641, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29909363

RESUMEN

OBJECTIVE: To study excitability of single motor units (MUs) using high-density surface-EMG. METHODS: Motor unit action potentials (MUAPs) were evoked by submaximal stimulation of the median nerve at the wrist and recorded with a 9 × 14 electrode grid on the skin overlying the thenar muscles. For excitability tests of single MUs, the most optimal specific single-channel surface-EMG signal was selected based on the spatiotemporal profile of single MUs. RESULTS: Axonal excitability measures were successfully obtained from 14 single MUs derived from ten healthy subjects. Selecting the optimal single-channel surface-EMG signals minimized interference from other single MUs and improved signal-to-noise ratio. The muscle fiber conduction velocity (MFCV) could also be derived from the unique spatiotemporal profile of single MUs. CONCLUSION: High-density surface-EMG helps to isolate single MUAP responses, making it a suitable technique for assessing excitability in multiple single motor axons per nerve. SIGNIFICANCE: Our method enables the reliable study of ion-channel dysfunction in single motor axons of nerves without any requirement for specific conditions, such as prominent MU loss or enlarged MUAPs due to collateral sprouting.


Asunto(s)
Electromiografía/métodos , Potenciales Evocados Motores/fisiología , Reclutamiento Neurofisiológico/fisiología , Potenciales de Acción/fisiología , Adolescente , Adulto , Estimulación Eléctrica/instrumentación , Estimulación Eléctrica/métodos , Femenino , Mano/inervación , Mano/fisiología , Humanos , Masculino , Adulto Joven
9.
Clin Neurophysiol ; 129(4): 809-814, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29477980

RESUMEN

OBJECTIVE: Sodium-potassium pump dysfunction in peripheral nerve is usually assessed by determining axonal hyperpolarization following maximal voluntary contraction (MVC) or maximal electrical nerve stimulation. As MVC may be unreliable and maximal electrical stimulation too painful, we assessed if hyperpolarization can also be induced by submaximal electrical nerve stimulation. METHODS: In 8 healthy volunteers different submaximal electrical stimulus trains were given to the median nerve at the wrist, followed by 5 min assessment of thresholds for compound muscle action potentials of 20%, 40% or 60% of maximal. RESULTS: Threshold increase after submaximal electrical nerve stimulation was most prominent after an 8 Hz train of at least 5 min duration evoking submaximal CMAPs of 60%. It induced minimal discomfort and was not painful. Threshold increase after MVC was not significantly higher than this stimulus train. CONCLUSIONS: Submaximal electrical stimulation evokes activity dependent hyperpolarization in healthy test subjects without causing significant discomfort. SIGNIFICANCE: Sodium-potassium pump function may be assessed using submaximal electrical stimulation.


Asunto(s)
Nervio Mediano/fisiología , Contracción Muscular/fisiología , ATPasa Intercambiadora de Sodio-Potasio/fisiología , Adulto , Estimulación Eléctrica/métodos , Femenino , Humanos , Masculino
10.
Muscle Nerve ; 57(4): 574-580, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-28877547

RESUMEN

INTRODUCTION: In some peripheral nervous system disorders, cold induces symptoms of muscle weakness without loss of sensation. To understand this selective effect on motor function, it is first essential to delineate the effects of cooling in motor and sensory axons of healthy subjects. METHODS: In 17 healthy volunteers, we performed excitability and clinical tests of median nerve motor and sensory axons at 37°C and at 20°C. Clinical tests consisted of assessing thenar muscle strength, 2-point discrimination, and joint position sense of the third finger. RESULTS: Excitability tests showed that cooling induced opposite changes to hyperpolarizing current in threshold electrotonus (motor, decreased threshold change; sensory, increased threshold change) and current-voltage relation slopes (motor, steepening; sensory, less steep). Clinical tests showed worsening in motor function but no consistent changes in sensory function. DISCUSSION: Cooling induces changes in motor axons consistent with depolarization and more complicated changes in sensory axons, possibly related to differences in hyperpolarization-activated cyclic nucleotide-gated channel expression. Muscle Nerve 57: 574-580, 2018.


Asunto(s)
Axones/fisiología , Mano , Neuronas Motoras/fisiología , Fuerza Muscular/fisiología , Propiocepción/fisiología , Células Receptoras Sensoriales/fisiología , Temperatura , Tacto/fisiología , Adulto , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Umbral Sensorial , Adulto Joven
11.
J Vasc Access ; 16(4): 327-32, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25768047

RESUMEN

PURPOSE: In order to find the correct final position of the tip of a central venous catheter, we have developed a new electric method (the Proximity of Cardiac Motion (PCM) method), designed to work in tandem with the existing ECG-based method. METHODS: A small, patient-safe, high-frequency current is fed through the catheter (via the saline-filled lumen of the catheter, or a stylet). Simultaneously, the resulting voltage is measured by two electrodes on the frontal thoracic skin. The catheter tip hence functions as a current source inside the vasculature. The cardiac motion produces a variation in the amplitude of the measured voltage in the rhythm of the cardiac cycle, and the strength of this oscillatory variation is proportional to the strength of the incident current field on the heart, which is a rapidly decaying function of the distance between the catheter tip and the cavoatrial junction (CAJ). Hence the strength of this oscillatory variation is a strong indicator for the proximity of the catheter tip with respect to the CAJ. RESULTS: The new method has been tested in an animal model, yielding an average final position of the catheter tip of 2.1 cm above the CAJ, with a maximum deviation of 0.5 cm. CONCLUSIONS: We conclude that the new PCM method can be combined with the existing ECG method, and may potentially have significant added value when the ECG method cannot be applied, for example, in patients with atrial fibrillation or a pacemaker.


Asunto(s)
Cardiografía de Impedancia/instrumentación , Cardiografía de Impedancia/métodos , Cateterismo Venoso Central/instrumentación , Cateterismo Venoso Central/métodos , Catéteres Venosos Centrales , Animales , Volumen Sanguíneo , Equipos y Suministros Eléctricos , Electricidad , Electrocardiografía , Diseño de Equipo , Estudios de Factibilidad , Modelos Animales , Valor Predictivo de las Pruebas , Procesamiento de Señales Asistido por Computador , Porcinos
12.
J Neuropsychiatry Clin Neurosci ; 27(2): e112-6, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25541864

RESUMEN

Sympathovagal balance, assessed with heart rate variability (HRV), may be altered in intensive care unit (ICU) delirium. HRV was measured in the frequency domain [low frequencies (LF)=0.04-0.15 Hz and high frequencies (HF)=0.15-0.40 Hz] with HF in normalized units (HFnu) to evaluate parasympathetic tone and LF:HF ratio for sympathovagal balance. The authors assessed 726 ICU patients and excluded patients with conditions affecting HRV. No difference could be found between patients with (N=13) and without (N=12) delirium by comparing the mean (±standard deviation) of the HFnu (75±7 versus 68±23) and the LF:HF ratio (-0.7±1.0 versus -0.1±1.1). This study suggests that autonomic function is not altered in ICU delirium.


Asunto(s)
Delirio/fisiopatología , Frecuencia Cardíaca/fisiología , Unidades de Cuidados Intensivos/estadística & datos numéricos , Adulto , Anciano , Delirio/epidemiología , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estadísticas no Paramétricas
13.
PLoS One ; 8(6): e67113, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23840596

RESUMEN

OBJECTIVE: In common peripheral neuropathies, sensory symptoms usually prevail over motor symptoms. This predominance of sensory symptoms may result from higher sensitivity of sensory axons to ischemia. METHODS: We measured median nerve compound sensory action potentials (CSAPs), compound muscle action potentials (CMAPs), and excitability indices in five healthy subjects during forearm ischemia lasting up to disappearance of both CSAPs and CMAPs. RESULTS: ISCHEMIA INDUCED: (1) earlier disappearance of CSAPs than CMAPs (mean ± standard deviation 30±5 vs. 46±6 minutes), (2) initial changes compatible with axonal depolarization on excitability testing (decrease in threshold, increase in strength duration time constant (SDTC) and refractory period, and decrease in absolute superexcitability) which were all more prominent in sensory than in motor axons, and (3) a subsequent decrease of SDTC reflecting a decrease in persistent Na(+) conductance during continuing depolarisation. INTERPRETATION: Our study shows that peripheral sensory axons are more vulnerable for ischemia than motor axons, with faster inexcitability during ischemia. Excitability studies during ischemia showed that this was associated with faster depolarization and faster persistent Na(+) channel inactivation in sensory than in motor axons. These findings might be attributed to differences in ion channel composition between sensory and motor axons and may contribute to the predominance of sensory over motor symptoms in common peripheral neuropathies.


Asunto(s)
Brazo/irrigación sanguínea , Axones/fisiología , Isquemia/fisiopatología , Neuronas Motoras/fisiología , Células Receptoras Sensoriales/fisiología , Potenciales de Acción , Adulto , Brazo/fisiopatología , Hipoxia de la Célula , Femenino , Humanos , Masculino , Persona de Mediana Edad , Conducción Nerviosa , Propiocepción
14.
Psychiatry Res ; 188(1): 133-7, 2011 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-21277026

RESUMEN

Movement disorders such as dyskinesia and Parkinsonism have frequently been reported in (drug-naïve) patients with nonaffective psychosis. Therefore movement disorders may be related to schizophrenia. Siblings of patients with nonaffective psychosis also appear to have subtle forms of movement disorders. This suggests that motor abnormalities may also be related to the risk of developing the disease. Subtle forms are not always detected with the use of the standard observation-based clinical rating scales, which are less sensitive than mechanical instrument measurement. This study compared the presence and severity of dyskinesia and Parkinsonism in 42 non-psychotic siblings of patients with nonaffective psychosis and in 38 controls as measured by mechanical instruments and clinical rating scales. There were no significant differences in movement disorders between siblings and controls on the basis of clinical assessments. However, mechanical measurements indicated that siblings compared to controls displayed significantly more dyskinesia and Parkinsonism signs. These results suggest that motor signs could be markers of vulnerability for psychosis or schizophrenia. In addition this study shows that mechanical instrument measurement of movement disorders is more sensitive than assessment with clinical rating scales. Therefore, it may be used in screening programs for populations at risk for psychosis.


Asunto(s)
Predisposición Genética a la Enfermedad/genética , Trastornos del Movimiento/genética , Trastornos del Movimiento/psicología , Trastornos Psicóticos/genética , Hermanos/psicología , Adolescente , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Examen Neurológico , Escalas de Valoración Psiquiátrica , Trastornos Psicóticos/psicología , Factores de Riesgo , Estadísticas no Paramétricas , Adulto Joven
15.
J Peripher Nerv Syst ; 15(3): 227-37, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21040145

RESUMEN

Cold paresis may occur in multifocal motor neuropathy and lower motor neuron disease. It was proposed to reflect nerve lesions where axons are depolarized due to loss of Na/K-pump activity. In those circumstances, a further decrease in pump activity by cooling may induce extra depolarization, conduction block, and weakness. Evidence for this hypothesis is incomplete because it is unknown if cold induces depolarization in human motor axons and other factors may contribute to the symptoms. To solve these questions, we examined 10 normal subjects. At 37, 25, 20, and 15°C we assessed: excitability in the median nerve, decrement on 3-Hz stimulation, pulsed Doppler of a wrist artery, and thenar muscle strength. Cooling induced: (1) findings compatible with axonal depolarization on excitability testing (fanning-in of threshold electrotonus, steepened current threshold relation, increased refractory period, decreased super- and subexcitability), (2) decreased Doppler peak systolic velocity without causing ischemia, (3) decreased muscle strength and impaired muscle relaxation. Decrement tests and compound muscle action potential amplitude remained normal. The excitability findings induced by cooling were best explained by axonal depolarization due to the effect of temperature on Na/K-pump activity. The induced weakness may be explained not only by this mechanism but also by impaired muscle contraction.


Asunto(s)
Potenciales de Acción/fisiología , Axones/fisiología , Frío/efectos adversos , Nervio Mediano/fisiopatología , Paresia/patología , Adulto , Axones/patología , Estimulación Eléctrica/métodos , Electromiografía/métodos , Femenino , Humanos , Masculino , Nervio Mediano/patología , Contracción Muscular/fisiología , Músculo Esquelético/fisiopatología , Conducción Nerviosa/fisiología , Temperatura , Adulto Joven
16.
Phys Med Biol ; 55(5): N133-40, 2010 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-20145293

RESUMEN

In this study, we demonstrate the proof of principle of the University Medical Center Utrecht (UMCU) robot dedicated to magnetic resonance imaging (MRI)-guided interventions in patients. The UMCU robot consists of polymers and non-ferromagnetic materials. For transperineal prostate interventions, it can be placed between the patient's legs inside a closed bore 1.5T MR scanner. The robot can manually be translated and rotated resulting in five degrees of freedom. It contains a pneumatically driven tapping device to automatically insert a needle stepwise into the prostate using a controller unit outside the scanning room. To define the target positions and to verify the needle insertion point and the needle trajectory, a high-resolution 3D balanced steady state free precession (bSSFP) scan that provides a T2/T1-weighted contrast is acquired. During the needle insertion fast 2D bSSFP images are generated to track the needle on-line. When the target position is reached, the radiation oncologist manually places a fiducial gold marker (small seed) at this location. In total two needle trajectories are used to place all markers. Afterwards, a high-resolution 3D bSSFP scan is acquired to visualize the fiducial gold markers. Four fiducial gold markers were placed transperineally into the prostate of a patient with a clinical stage T3 prostate cancer. In the generated scans, it was possible to discriminate the patient's anatomy, the needle and the markers. All markers were delivered inside the prostate. The procedure time was 1.5 h. This study proves that MRI-guided needle placement and seed delivery in the prostate with the UMCU robot are feasible.


Asunto(s)
Biopsia con Aguja/métodos , Imagen por Resonancia Magnética , Próstata/patología , Robótica/métodos , Centros Médicos Académicos , Anciano , Estudios de Factibilidad , Humanos , Masculino
17.
ASAIO J ; 55(6): 575-80, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19812475

RESUMEN

Intradialytic hypotension is often caused by a discrepancy between ultrafiltration and plasma refilling. Increasing the plasma refill rate could therefore reduce intradialytic hypotension. We used a recently developed method to measure the effect of cool dialysate and sodium (Na) profiling on refill during hemodialysis (HD). Using a Gambro AK200 with blood volume (BV) sensor plus computer-guided external pump, a high ultrafiltration rate quickly induced a preset BV reduction. A software feedback mechanism subsequently adjusted the ultrafiltration rate continuously to maintain BV between very narrow preset boundaries. The continuously changing, software-generated ultrafiltration rate then quantitatively equalled refill. Absolute plasma refill rate was measured in six stable patients without intradialytic hypotension, undergoing HD without intervention, with cool dialysate (1 degrees C below core temperature), and with Na profiling (gradually declining from 150 to 140 mmol/l). Baseline refill rate was 20.1 + or - 4.0 ml/min (mean + or - SD). Although cool dialysate did not affect refill (22.2 + or - 4.1 ml/min, p = 0.27 vs. baseline), Na profiling induced a significant improvement (26.8 + or - 3.7 ml/min, p = 0.006 vs. baseline). Using our method to measure absolute plasma refill rate during HD, we demonstrated that Na profiling indeed improves the plasma refill rate. A potential effect of cool dialysate could not be established.


Asunto(s)
Soluciones para Diálisis/química , Hipotensión/prevención & control , Diálisis Renal/efectos adversos , Diálisis Renal/métodos , Sodio/análisis , Humanos , Hipotensión/etiología
18.
Clin Auton Res ; 18(1): 28-35, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18236004

RESUMEN

OBJECTIVE: The cardiovascular response to a meal is modulated by gastric distension and the interaction of nutrients, particularly carbohydrate, within the small intestine. We tested the hypothesis that the depressor effect of small intestinal glucose is greater in older than in young subjects, because the reflex increase in muscle sympathetic nerve activity (MSNA) is blunted by age. METHODS: The effects of intraduodenal glucose infusion (IDGI) on blood pressure, heart rate and MSNA were evaluated in eight healthy young subjects (4 women; mean age +/- SEM: 28.8 +/- 3.4 years), eight healthy elderly (4 women; 75.3 +/- 1.6 years) and in two patients with symptomatic postprandial hypotension (PPH), one young (21 years), and one old (90 years). RESULTS: In both young and elderly healthy subjects, IDGI decreased blood pressure (P < 0.05), but the fall in systolic blood pressure was greater in the older subjects (-17.0 +/- 4.1 vs. -6.5 +/- 1.6 mmHg, P < 0.03). MSNA increased similarly, after infusion in both young (9.0 +/- 3.4 bursts/min) and elderly (7.8 +/- 1.0 bursts/min) subjects. Baroreflex sensitivity for number of sympathetic bursts was attenuated in the elderly (P < 0.03). The increase in burst area in the young patient with PPH was attenuated (18 vs. 63% in the healthy young group). INTERPRETATION: The fall in BP induced by IDGI was greater in healthy elderly compared to healthy young subjects. The reason for this is unclear, as they have similar increases in MSNA.


Asunto(s)
Duodeno/fisiología , Glucosa/administración & dosificación , Músculo Esquelético/inervación , Músculo Esquelético/fisiología , Sistema Nervioso Simpático/fisiología , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Barorreflejo/efectos de los fármacos , Barorreflejo/fisiología , Presión Sanguínea/efectos de los fármacos , Presión Sanguínea/fisiología , Duodeno/efectos de los fármacos , Femenino , Frecuencia Cardíaca/efectos de los fármacos , Frecuencia Cardíaca/fisiología , Humanos , Hipotensión/inducido químicamente , Intubación Gastrointestinal , Sistema Nervioso Simpático/efectos de los fármacos
19.
Clin Neurophysiol ; 119(4): 869-79, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18258478

RESUMEN

OBJECTIVE: Sympathetic baroreflex sensitivity (symBRS) can be defined as the maximum sensitivity of muscle sympathetic nerve activity (MSNA) to changes in arterial blood pressure. This sensitivity is the slope of the linear middle part of the sigmoid curve that relates blood pressure to MSNA. SymBRS is known to vary with conditions, for instance during cold pressor testing. We investigated whether symBRS is affected by infusions of phenylephrine and nitroprusside. METHODS: In 10 healthy subjects, vasoactive infusions were varied in slow steps, as customary in protocols to determine 'graded infusion symBRS' (symBRS(inf)). During each step, symBRS was estimated from spontaneous beat-to-beat fluctuations (symBRS(sp)). As a secondary goal, symBRS(inf) was compared to the symBRS(sp) without infusions. RESULTS: The symBRS(sp) for MSNA burst area varied with infusions, augmenting with decreasing blood pressure, however the symBRS(sp) for burst occurrence was not affected. There were large differences between symBRS(inf) and symBRS(sp) at rest. CONCLUSIONS: symBRS(sp) varies systematically with infusions during a symBRS(inf) protocol. This denotes a fundamental difference between these methods. SIGNIFICANCE: The relationship between 'slow' infusion effects (symBRS(inf)) and changes in symBRS(sp) is elucidated. The mathematical model that describes this relationship can also explain the increase of symBRS found with other sympathoexcitatory stimuli.


Asunto(s)
Barorreflejo/fisiología , Presión Sanguínea/fisiología , Sistema Nervioso Simpático/fisiología , Adulto , Barorreflejo/efectos de los fármacos , Presión Sanguínea/efectos de los fármacos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Teóricos , Músculos/inervación , Nitroprusiato/farmacología , Fenilefrina/farmacología , Sistema Nervioso Simpático/efectos de los fármacos , Tiempo , Vasoconstrictores/farmacología , Vasodilatadores/farmacología
20.
ASAIO J ; 54(1): 95-9, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18204322

RESUMEN

Methods to continuously measure absolute refill during dialysis are not available. It would be useful to have such a method because it would allow investigating the mechanism of refill the effect of interventions. We designed a feedback algorithm that adjusts ultrafiltration rate (QUF) according to hemoglobin (Hb) concentration changes in such a way that relative blood volume (BV) remains constant within a narrow target range. In this situation, the generated QUF quantitatively reflects refill. Refill patterns were studied in five hypotension prone patients. In addition, on separate occasions, we studied the effect of antiembolism stockings (AES) and infusion of hydroxy-ethylated starch (HAES) on refill in these patients. Refill during the first hour fell significantly from 21 +/- 3 ml/min to 9 +/- 2 ml/min (p < 0.05). In the second hour, refill decreased further and became zero in four out of five patients. Neither AES nor HAES measurably affected refill. The marked and rapid fall in refill in the early stages of dialysis suggests untimely depletion of the interstitial compartment and underestimation of dry weight. We propose that continuous, online measurement of refill patterns may be of value for accurate estimation of dry weight in dialysis patients.


Asunto(s)
Hemodiafiltración/instrumentación , Diálisis Renal/instrumentación , Diálisis Renal/métodos , Ultrafiltración/instrumentación , Anciano , Anciano de 80 o más Años , Volumen Sanguíneo , Hemodiafiltración/métodos , Soluciones para Hemodiálisis/farmacología , Hemoglobinas/química , Humanos , Derivados de Hidroxietil Almidón/química , Hipotensión/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Sistemas en Línea , Reproducibilidad de los Resultados , Ultrafiltración/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA