Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Vasc Access ; : 11297298231218663, 2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-38166456
2.
J Vasc Access ; : 11297298231180627, 2023 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-37334775

RESUMEN

OBJECTIVE: Clinical guidelines provide recommendations on the minimal blood vessel diameters required for arteriovenous fistula creation but the evidence for these recommendations is limited. We compared vascular access outcomes of fistulas created in agreement with the ESVS Clinical Practice Guidelines (i.e. arteries and veins >2 mm for forearm fistulas and >3 mm for upper arm fistulas) with fistulas created outside these recommendations. METHODS: The multicenter Shunt Simulation Study cohort contains 211 hemodialysis patients who received a first radiocephalic, brachiocephalic, or brachiobasilic fistula before publication of the ESVS Clinical Practice Guidelines. All patients had preoperative duplex ultrasound measurements according to a standardized protocol. Outcomes included duplex ultrasound findings at 6 weeks after surgery, vascular access function, and intervention rates until 1 year after surgery. RESULTS: In 55% of patients, fistulas were created in agreement with the ESVS Clinical Practice Guidelines recommendations on minimal blood vessel diameters. Concordance with the guideline recommendations was more frequent for forearm fistulas than for upper arm fistulas (65% vs 46%, p = 0.01). In the entire cohort, agreement with the guideline recommendations was not associated with an increased proportion of functional vascular accesses (70% vs 66% for fistulas created within and outside guideline recommendations, respectively; p = 0.61) or with decreased access-related intervention rates (1.45 vs 1.68 per patient-year, p = 0.20). In forearm fistulas, however, only 52% of arteriovenous fistulas created outside these recommendations developed into a timely functional vascular access. CONCLUSIONS: Whereas upper arm arteriovenous fistulas with preoperative blood vessel diameters <3 mm had similar vascular access function as fistulas created with larger blood vessels, forearm arteriovenous fistulas with preoperative blood vessel diameters <2 mm had poor clinical outcomes. These results support that clinical decision-making should be guided by an individual approach.

4.
Eur J Vasc Endovasc Surg ; 65(4): 555-562, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36646270

RESUMEN

OBJECTIVE: Although observational cohort studies report that interventions to achieve functionality are clinically successful in 85% of patients, the proportion of newly created autologous arteriovenous fistulas that result in functional vascular access typically is only 70 - 80%. To address this discrepancy, the selection and outcomes of interventions to achieve functionality in a multicentre prospective cohort study were analysed. METHODS: The Shunt Simulation Study enrolled 222 patients who needed a first arteriovenous fistula in nine dialysis units in The Netherlands from 2015 to 2018 and followed these patients until one year after access creation. In this observational study, the technical and clinical success rates of interventions to achieve functionality based on lesion and intervention characteristics were analysed and the clinical outcomes of arteriovenous fistulas with assisted and unassisted functionality were compared. RESULTS: For patients who were on dialysis treatment at the end of the study, unassisted fistula functionality was 54% and overall fistula functionality was 78%. Thirty-four per cent of arteriovenous fistulas required an intervention to achieve functionality, 68% of which eventually became functional. Seventy-five per cent of these interventions were percutaneous balloon angioplasties of vascular access stenoses. Patients with clinically successful interventions to achieve functionality had larger pre-operative vein diameters (2.8 ± 1.0 mm vs. 2.3 ± 0.6 mm, p = .036) and less often presented with thrombosed fistulas than patients with unsuccessful interventions (7% vs. 43%, p = .006). Arteriovenous fistulas with assisted functionality had similar secondary patency as fistulas with unassisted functionality (100% and 98% at six months, p = .44), although they required more interventions to maintain function (2.6 vs. 1.7 per year; rate ratio 1.52, 95% CI 1.04 - 2.18, p = .032). CONCLUSION: Interventions to achieve functionality were needed in about a third of newly created arteriovenous fistulas. Most thrombosed fistulas were abandoned, and when selected for thrombectomy rarely reached clinical success. On the other hand, interventions to achieve functionality of patent fistulas had high clinical success rates and therefore can be done repeatedly until the fistula has become functional.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...