Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 38
1.
Article En | MEDLINE | ID: mdl-38589503

INTRODUCTION: It is unclear if elderly patients treated with plate osteosynthesis for proximal humerus fractures benefit from cement augmentation. This meta-analysis aims to compare cement augmentation to no augmentation regarding healing, complications, and functional results. METHODS: PubMed, Embase, and Cochrane Central Register of Controlled Trials were searched for randomized clinical trials and observational studies. Effect estimates were pooled across studies using random effects models. The primary outcome is overall complication rate. Stratified analyses were performed for types of complication (implant-related or systemic). Secondary outcomes include re-interventions, hospital stay, operation time, functional scores, and general quality of life. RESULTS: Five observational studies and one randomized controlled trial with a total of 541 patients were included. The overall complication rate was significantly lower in the augmented group (15.6% versus 25.4%, OR 0.54 (95%CI 0.33-0.87)). This was caused by a reduction of implant-related complications (10.4% vs. 19.9%, OR 0.49 (95%CI 0.28, 0.88)). No difference in humeral head necrosis was found. Data on re-intervention, hospital stay, and operation time was limited but did not show significant differences. No impact on functional scores and general quality of life was detected. CONCLUSION: This meta-analysis shows that cement augmentation may reduce overall complications, mainly by preventing implant-related complications. No difference was detected regarding need for re-intervention, functional scores, general quality of life, and hospital stay. This is the first meta-analysis on this topic. It remains to be seen whether conclusions will hold when more and better-quality data becomes available.

2.
JMIR Res Protoc ; 13: e52917, 2024 Feb 13.
Article En | MEDLINE | ID: mdl-38349719

BACKGROUND: Distal radius fractures are the most frequently encountered fractures in Western societies, typically affecting patients aged 50 years and older. Although this is a common injury, the best treatment for these fractures in older patients is still under debate. OBJECTIVE: This prospective study aims to compare the outcome of operatively and nonoperatively treated distal radius fractures in the older population. Only patients with distal radius fractures for which equipoise regarding the optimal treatment exists will be included. METHODS: This prospective international multicenter observational cohort study will be designed as a natural experiment. Natural experiments are observational studies in which treatment allocation is determined by factors outside the control of the investigators but also (largely) independent of patient characteristics. Patients aged 65 years and older with an acute distal radius fracture will be considered for inclusion. Treatment allocation (operative vs nonoperative) will be based on the local preferences of the treating hospital either in Switzerland or the Netherlands. Hence, the process governing treatment allocation resembles that of randomization. Patients will be identified after treatment has been initiated. Based on the radiographs and baseline information of the patient, an expert panel of 6 certified trauma surgeons from 2 regions will provide their treatment recommendation. Only patients for whom the experts disagree on treatment recommendations will ultimately be included in the study (ie, for whom there is a clinical equipoise). For these patients, both operative and nonoperative treatment of distal radius fractures are viable, and treatment choice is predominantly determined by personal or local preference. The primary outcome will be the Patient-Rated Wrist Evaluation score at 12 weeks. Secondary outcomes will include the Physical Activity Score for the Elderly, the EQ questionnaire, pain, the living situation, range of motion, complications, and radiological outcomes. By including outcomes such as living situation and the Physical Activity Score for the Elderly, which are not relevant for younger cohorts, valuable information to tailor treatment to the needs of the older population can be gained. According to the sample size collection, which was based on the minimal important clinical difference of the Patient-Rated Wrist Evaluation, 92 patients will have to be included, with at least 46 patients in each treatment group. RESULTS: Enrollment began in July 2023 and is expected to continue until summer 2024. The final follow-up will be 2 years after the last patient is included. CONCLUSIONS: Although many trials on this topic have previously been published, there remains an ongoing debate regarding the optimal treatment for distal radius fractures in older patients. This observational study, which will use a fairly new methodological study design, will provide further information on treatment outcomes for older patients with distal radius fractures for which to date equipoise exists regarding the optimal treatment. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/52917.

3.
PLoS One ; 18(9): e0291238, 2023.
Article En | MEDLINE | ID: mdl-37683048

BACKGROUND: Single plate osteosynthesis is commonly employed when performing surgical stabilization of midshaft clavicle fractures. In recent years, a smaller structural low-profile double plating technique has been described as a possible solution for the high removal rates associated with single plating. A previous meta-analysis has demonstrated that low-profile double plating attains the same healing rates as single plating without a higher chance of fracture-related infections. This meta-analysis, however, was based on relatively small studies. Therefore, a multicentre prospective natural experiment was designed using natural variation in treatment regimens and geographical location of the trauma as treatment allocation mechanism to compare both treatments on a larger scale. This manuscript describes its protocol. MATERIAL & METHODS: Patients (≥16 years) with primary midshaft clavicle fractures that are eligible for operative treatment will be included. Treatment allocation will be determined by the geographical location of the accident and local hospital providing treatment. In two centres, single plating is the treatment of choice for these patients. In two others, low-profile double plating has become the standard treatment. For the low-profile double plating group, one superiorly positioned VariAx 2.0mm and one anterior VariAx 2.4mm or 2.7mm plate will be used. For the single plating group, the standard locally available implant will be used. A total of 336 patients will be included. The primary outcome of interest is re-intervention. Secondary outcomes include complications, operative time, length of incision, functional scores (DASH, EQ-5D-DL, VAS-Pain/Satisfaction) and cost-effectiveness. DISCUSSION: This study will determine whether low-profile double plating has significant clinical and cost-effective benefits over single plating techniques in midshaft clavicle fractures. The study will also give insight in the performance of a natural experiment study design for orthopedic trauma research. TRIAL REGISTRATION: This study has been registered on ClincialTrials.gov, identifier NCT05579873.


Clavicle , Fractures, Bone , Humans , Clavicle/surgery , Prospective Studies , Fractures, Bone/surgery , Fracture Fixation, Internal , Bone Plates , Meta-Analysis as Topic
4.
Oper Orthop Traumatol ; 35(6): 352-369, 2023 Dec.
Article De | MEDLINE | ID: mdl-37395767

OBJECTIVE: The aim of surgical treatment is fracture healing with restored alignment, rotation, and joint surface. Stable fixation allows for functional postoperative aftercare. INDICATIONS: Displaced intra- and extra-articular fractures which either could not be adequately reduced or in which a secondary displacement is to expected due to instability criteria. The following factors are considered instability criteria: age > 60 years, female, initial dorsal displacement > 20°, dorsal comminution, radial shortening > 5 mm, palmar displacement. CONTRAINDICATIONS: The only absolute contraindication is if the patient is deemed unfit for surgery due to concerns regarding anesthesia. Old age is a relative contraindication, as it is currently debated whether older patients benefit from the operation. SURGICAL TECHNIQUE: The surgical technique is guided by the fracture pattern. Palmar plating is most commonly performed. If the joint surface needs to be visualized, a dorsal approach (in combination with another approach or alone) or arthroscopically assisted fixation should be chosen. POSTOPERATIVE MANAGEMENT: In general, a functional postoperative regime can be carried out after plate fixation with mobilization without weightbearing. Short-term splinting can provide pain relief. Concomitant ligamentous injuries and fixations, which are not stable enough for functional aftercare (such as k­wires) require a longer period of immobilization. RESULTS: Provided the fracture is reduced correctly, osteosynthesis improves functional outcome. The complication rate ranges between 9 and 15% with the most common complication being tendon irritation/rupture and plate removal. Whether surgical treatment holds the same benefits for patients > 65 years as for younger patients is currently under debate.


Radius Fractures , Tendon Injuries , Wrist Fractures , Wrist Injuries , Humans , Female , Middle Aged , Radius Fractures/diagnosis , Radius Fractures/surgery , Treatment Outcome , Bone Wires/adverse effects , Wrist Injuries/complications , Wrist Injuries/surgery , Fracture Fixation, Internal/methods , Bone Plates/adverse effects
5.
Arthroplasty ; 5(1): 20, 2023 Apr 07.
Article En | MEDLINE | ID: mdl-37024967

BACKGROUND: Intraoperative fluoroscopy (IFC) is gaining popularity in total hip arthroplasty (THA), with the aim to achieve better component positioning and therefore eventually reduced revision rates. This meta-analysis investigated the benefit of IFC by comparing it to intraoperative assessment alone. The primary outcome was component positioning and the secondary outcomes included complications and revision rates. METHODS: PubMed, Embase and Cochrane Central Register of Controlled Trials were searched for both randomized clinical trials (RCT) and observational studies. Effect estimates for radiographic cup position, offset/leg length difference and outliers from a safe zone were pooled across studies using random effects models and presented as a weighted odds ratio (OR) with a corresponding 95% confidence interval (95% CI). RESULTS: A total of 10 observational studies involving 1,394 patients were included. No randomized trials were found. IFC showed no significant reduction in acetabular cup position (inclination and anteversion), offset, leg-length discrepancies, revision (none reported) or overall complication rates. CONCLUSION: The current meta-analysis found no differences in cup positioning, offset, leg length discrepancy, the incidence of complications or revision surgery. It should be acknowledged that the included studies were generally performed by experienced surgeons. The benefit of intraoperative fluoroscopy might become more evident at an early phase of the learning curve for this procedure. Therefore, its role has yet to be defined.

6.
Plast Reconstr Surg ; 151(5): 949-957, 2023 05 01.
Article En | MEDLINE | ID: mdl-36729428

BACKGROUND: The perioperative use of tranexamic acid (TXA) has become popular among plastic surgeons for a variety of surgical procedures. The aim of this study was to perform a systematic review and meta-analysis on the results reported in the literature regarding the effect of perioperative systemic TXA administration in breast surgery. METHODS: The PubMed, MEDLINE, Embase, CENTRAL, and CINAHL databases were searched for both randomized clinical trials and observational studies. Effect estimates were pooled across studies using random effects models and presented as weighted odds ratio with corresponding 95% confidence interval. RESULTS: A total of five studies encompassing 1139 patients undergoing mastectomy with or without immediate implant or free flap-based breast reconstruction or breast-conserving surgery with or without axillary lymph node dissection were included. Perioperative intravenous administration of TXA significantly reduced the risk for hematoma (7.3% versus 12.9%; OR, 0.43; 95% CI, 0.23 to 0.81) and seroma formation (11.5% versus 19.9%; OR, 0.57; 95% CI, 0.35 to 0.92) in comparison to the control group. In the studies measuring the postoperative drainage amount, the mean difference was 132 mL (95% CI, 220 to 44 mL). No thromboembolic event occurred in either group. The weighted surgical-site infection rate was higher in the control group (3.1% versus 1.5%). However, these data were too sparse to perform comparative meta-analysis. CONCLUSION: Evidence of this study suggests that perioperative administration of TXA significantly reduces the risk for postoperative hematoma and seroma formation in breast surgery, whereas the risk for thromboembolic events and postoperative infection is not increased.


Antifibrinolytic Agents , Breast Neoplasms , Thromboembolism , Tranexamic Acid , Humans , Female , Tranexamic Acid/therapeutic use , Antifibrinolytic Agents/therapeutic use , Seroma/epidemiology , Seroma/etiology , Seroma/prevention & control , Breast Neoplasms/surgery , Breast Neoplasms/drug therapy , Mastectomy/adverse effects , Hematoma/etiology , Hematoma/prevention & control , Blood Loss, Surgical/prevention & control
7.
Eur J Trauma Emerg Surg ; 49(5): 2071-2084, 2023 Oct.
Article En | MEDLINE | ID: mdl-36750472

PURPOSE: The objective of this systematic review was to perform epidemiological as well as clinical, radiological and patient-reported outcome analysis of surgically treated perilunate dislocations and fracture dislocations (PLDs and PLFDs) based on the so far largest pooled patient population to date. MATERIAL AND METHODS: This systematic review was written according to the updated guideline for reporting systematic reviews by the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) statement. A comprehensive literature search of Pubmed, Embase, CENTRAL, and CINAHL databases was performed. All studies reporting on complications, radiological, functional and/or patient-reported outcomes of surgically treated acute PLDs and PLFDs with a minimum follow-up of 12 months were included. RESULTS: Twenty-six studies encompassing 550 patients with 553 operatively treated acute perilunate injuries (106 PLDs and 447 PLFDs) were included. The overall postoperative complication rate was 15.0% with secondary reduction loss representing the main contributing factor (10.1%). The overall reoperation rate was 10.4% and the incidence of salvage procedures was 2.8%. The risk for secondary reduction loss was higher for PLD than for PLFD injuries (24.2% vs. 7.0%, relative risk [RR] 3.5, 95% confidence interval [CI] 1.6-7.5). There was a higher overall complication rate for the combined dorsopalmar approach when compared to the isolated dorsal approach (17.4% vs. 8.4%, RR 0.5, 95% CI 0.2-1.0, number needed to treat [NNT] 11.2) and for open surgery versus arthroscopic surgery (17.4% vs. 4.8%, RR 0.3, 95% CI 0.1-0.9, NNT 8.0). A significant correlation was found between radiological osteoarthritis (rOA) and follow-up duration of the individual studies, while functional and patient-rated outcomes were comparable. CONCLUSIONS: Regardless of surgical technique, PLFDs appear to be less susceptible to secondary reduction loss than PLDs. Whenever possible, less invasive (e.g. arthroscopic) surgery should be performed to minimize postoperative complications. The rate of rOA is high and increases significantly with follow-up duration. Interestingly, rOA does not seem to correlate with reduced wrist function nor patient dissatisfaction and the need for salvage surgery is surprisingly rare. LEVEL OF EVIDENCE: Systematic review of level IV studies.


Fracture Dislocation , Fractures, Bone , Joint Dislocations , Lunate Bone , Wrist Injuries , Humans , Lunate Bone/diagnostic imaging , Lunate Bone/surgery , Lunate Bone/injuries , Fractures, Bone/surgery , Fractures, Bone/complications , Joint Dislocations/surgery , Wrist Injuries/diagnostic imaging , Wrist Injuries/surgery , Postoperative Complications/epidemiology
8.
J Bone Joint Surg Am ; 105(3): 207-213, 2023 02 01.
Article En | MEDLINE | ID: mdl-36622896

BACKGROUND: The aim of this single-center randomized controlled trial was to compare primary wound closure using a suture with secondary wound healing of pin sites after removal of temporary external fixation. METHODS: This noninferiority trial included all patients who were treated with a temporary external fixator on an upper or lower extremity at 1 institution. The primary outcome was pin-site infection. Secondary outcomes were measured at 2, 6, 12, 24, and 52 weeks and included all other complications, time to pin-site wound healing (in weeks), the most satisfactory pin site as rated by the patient, the visual analog scale (VAS) score for pain, and the Vancouver Scar Scale (VSS). The most proximal pin site was randomly allocated (1:1) to either primary closure or secondary wound healing, and the other pin sites were treated alternately. RESULTS: Seventy patients, providing 241 pin sites, were included between January 1, 2019, and March 1, 2020. A total of 123 pin sites were treated with primary closure and 118, with secondary wound healing. The median age was 55 years (interquartile range, 46 to 67 years), 44% were male, and the median duration of the external fixation was 6 days (interquartile range, 4 to 8 days). There were no pin-site infections in either group. Wound healing was significantly faster in the primary closure group (median of 2 versus 6 weeks, p = 0.013). The VSS and patient satisfaction showed no differences between groups. There was 1 case of fracture-related infection not related to any pin site. CONCLUSIONS: Primary closure of temporary external fixator pin sites did not result in higher infection rates compared with secondary wound healing, and pin sites healed significantly faster after primary closure. Primary closure should therefore be considered in patients treated with a temporary external fixator. LEVEL OF EVIDENCE: Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.


External Fixators , Fractures, Bone , Humans , Male , Middle Aged , Female , Treatment Outcome , Wound Healing , Fractures, Bone/etiology , Fracture Fixation/adverse effects , Cicatrix/etiology
9.
Eur J Orthop Surg Traumatol ; 33(4): 1421-1426, 2023 May.
Article En | MEDLINE | ID: mdl-35704065

INTRODUCTION: The Arbeitsgemeinschaft für Osteosynthesefragen (AO) foundation along with the Orthopaedic. Trauma Association (OTA) introduced a new classification for sternal fractures in 2018 aiming to provide greater uniformity and clinical utility for the surgical community. A previous validation study identified some critical issues such as the differentiation between type A and B fractures and localization of the fracture either in the manubrium or in the body. Due to the moderate agreement in inter- and intra-observer variability, some modifications were proposed in order to improve the performance of the classification. The aim of this study was to re-assess the inter- and intra-observer variability after adding modifications to the classification. Our hypothesis was that a significative improvement of inter- and intra-observer variability could be achieved. MATERIAL AND METHODS: Twenty computed tomography (CT) scans of patients with sternal fractures were analyzed by six. Junior and six senior surgeons independently. Two assessments were performed with an interval of 6 weeks. The kappa (K) value was calculated in order to assess inter- and intra-observer variability. RESULTS: The overall mean kappa value for inter-observer variability improved from 0.364 to 0.468 (p < 0.001). Inter-observer variability mean for location was 0.573 (SD 0.221) and for type was 0.441 (SD: 0.181). Intra-observer variability showed a mean of 0.703 (SD: 0.153) with a statistic significant improvement when compared to the previous study (mean 0.414, SD: 0.256, p < 0.001). CONCLUSIONS: By modifying the AO/OTA classification of sternal fractures, the inter- and intra-observer variability improved and now shows moderate to substantial agreement.


Fractures, Bone , Thoracic Injuries , Humans , Reproducibility of Results , Tomography, X-Ray Computed/methods , Sternum , Observer Variation
10.
Arch Orthop Trauma Surg ; 143(2): 887-893, 2023 Feb.
Article En | MEDLINE | ID: mdl-35137253

BACKGROUND: Multiple rib fractures are associated with significant morbidity and mortality, especially in elderly patients. There is growing interest in surgical stabilization in this subgroup of patients. This systematic review compares conservative treatment to surgical fixation in elderly patients (older than 60 years) with multiple rib fractures. The primary outcome is mortality. Secondary outcomes include hospital and intensive care length of stay (HLOS and ILOS), duration of mechanical ventilation (DMV) and pneumonia rates. METHODS: Multiple databases were searched for comparative studies reporting on conservative versus operative treatment for rib fractures in patients older than 60 years. Both observational studies and randomised clinical trials were considered. RESULTS: Five observational studies (n = 2583) were included. Mortality was lower in operatively treated patients compared to conservative treatment (4% vs. 8%). Pneumonia rate and DMV were similar (5/6% and 5.8/6.5 days) for either treatment modality. Overall ILOS and HLOS of stay were longer in operatively treated patients (6.5 ILOS and 12.7 HLOS vs. 2.7 ILOS and 6.5 ILOS). There were only minimal reports on perioperative complications. Notably, the median number of rib fractures (8.4 vs. 5) and the percentage of flail chest were higher in operatively treated patients (47% vs. 39%). CONCLUSION: It remains unknown to what extent conservative and operative treatment contribute individually to reducing morbidity and mortality in the elderly with multiple rib fractures. To date, the quality of evidence is rather low, thus well-performed comparative observational studies or randomised controlled trials considering all confounders are needed to determine whether operative treatment can improve a patient's outcome.


Flail Chest , Pneumonia , Rib Fractures , Spinal Fractures , Humans , Aged , Rib Fractures/surgery , Rib Fractures/complications , Flail Chest/surgery , Length of Stay , Fracture Fixation/adverse effects , Spinal Fractures/complications , Pneumonia/etiology , Pneumonia/complications , Retrospective Studies
11.
Injury ; 54(2): 429-434, 2023 Feb.
Article En | MEDLINE | ID: mdl-36402587

Natural experiments are observational studies of medical treatments in which treatment allocation is determined by factors outside the control of the investigators, arguably resembling experimental randomisation. Natural experiments in the field of orthopaedic trauma research are scarce. However, they have great potential due to the process governing treatment allocation and the existence of opposing treatment strategies between hospitals or between regions as a result of local education, conviction, or cultural and socio-economic factors. Here, the possibilities and opportunities of natural experiments in the orthopaedic trauma field are discussed. Potential solutions are presented to improve the validity of natural experiments and how to assess the credibility of such studies. Above all, it is meant to spark a discussion about its role within the field of orthopaedic trauma research.


Orthopedics , Humans , Orthopedics/education , Hospitals
12.
Medicina (Kaunas) ; 58(12)2022 Dec 09.
Article En | MEDLINE | ID: mdl-36557015

The ideal surgical treatment of femoral neck fractures remains controversial. When treating these fractures with internal fixation, many fixation constructs exist. The primary aim of this study was to evaluate the incidence and specific risk factors associated with complication and re-operation following fixation of intracapsular proximal femoral fractures using the Targon-FN system (B.Braun Melsungen AG). A secondary aim was to identify if lateral prominence of the implant relative to the lateral border of the vastus ridge was a specific risk factor for elective plate removal. Methodically, a retrospective case series was conducted of all consecutive adult patients treated at a single level 1 trauma center in Switzerland for an intracapsular proximal femoral fracture with the Targon-FN. Demographic data were collected. Patients with a follow-up of less than three months were excluded. Complications as well as plate position were recorded. Statistical analysis to identify specific risk factors for re-operation and complications was performed. In result, a total of 72 cases with intracapsular femoral neck fractures were treated with the Targon-FN locking plate system between 2010 and 2017. Thirty-four patients (47.2%) experienced one or more complications. The most common complication was mechanical irritation of the iliotibial band (ITB) (23.6%, n = 17). Complications included intraarticular screw perforation (6.9%, n = 5), avascular necrosis (5.6%, n = 4), non-union (5.6%, n = 4) among others. In total, 46 re-operations were required. Younger age, fracture displacement and time to postoperative weight bearing were identified as risk factors for re-operation. In conclusion, intracapsular femoral neck fractures treated with the Targon-FN system resulted in a high rate of post-operative complication and re-operation. Statistical analysis revealed patient age, fracture displacement, time to postoperative full weight bearing were risk factors for re-operation. The main limitation is the limited number of cases and a short follow-up of less than 12 months in a subgroup of our patients.


Femoral Neck Fractures , Proximal Femoral Fractures , Adult , Humans , Retrospective Studies , Femoral Neck Fractures/surgery , Bone Screws/adverse effects , Reoperation , Fracture Fixation, Internal/adverse effects , Bone Plates/adverse effects
13.
Eur J Trauma Emerg Surg ; 48(6): 4943-4953, 2022 Dec.
Article En | MEDLINE | ID: mdl-35809102

PURPOSE: It is challenging to generate and subsequently implement high-quality evidence in surgical practice. A first step would be to grade the strengths and weaknesses of surgical evidence and appraise risk of bias and applicability. Here, we described items that are common to different risk-of-bias tools. We explained how these could be used to assess comparative operative intervention studies in orthopedic trauma surgery, and how these relate to applicability of results. METHODS: We extracted information from the Cochrane risk-of-bias-2 (RoB-2) tool, Risk Of Bias In Non-randomised Studies-of Interventions tool (ROBINS-I), and Methodological Index for Non-Randomized Studies (MINORS) criteria and derived a concisely formulated set of items with signaling questions tailored to operative interventions in orthopedic trauma surgery. RESULTS: The established set contained nine items: population, intervention, comparator, outcome, confounding, missing data and selection bias, intervention status, outcome assessment, and pre-specification of analysis. Each item can be assessed using signaling questions and was explained using good practice examples of operative intervention studies in orthopedic trauma surgery. CONCLUSION: The set of items will be useful to form a first judgment on studies, for example when including them in a systematic review. Existing risk of bias tools can be used for further evaluation of methodological quality. Additionally, the proposed set of items and signaling questions might be a helpful starting point for peer reviewers and clinical readers.


Orthopedic Procedures , Humans , Bias , Selection Bias
14.
Clin Biomech (Bristol, Avon) ; 94: 105634, 2022 04.
Article En | MEDLINE | ID: mdl-35367818

BACKGROUND: Implant removal rates after clavicle plating are high. Recently, low-profile dual mini-fragment plate constructs have revealed lower implant removal rates following fixation of diaphyseal clavicle fractures. However, they have not been subject to a biomechanical investigation. AIMS: To: (1) investigate thebiomechanical competence of different dual plate designs and (2) compare them against single superoanterior plating. METHODS: Twelve artificial clavicles with a simulated AO/OTA 15.2C unstable diaphyseal clavicle fracture were assigned to 2 groups and instrumented with dual titanium mandible plates as follows: Group 1 - 2.5 mm anterior plus 2.0 mm superior (2.5/2.0); Group 2 - 2.0 mm anterior plus 2.0 mm superior (2.0/2.0). Specimens were cyclically tested to failure under craniocaudal cantilever bending superimposed with torsion around the shaft axis and compared to previous published data acquired using 6 locking superoanterior plates tested under the same conditions (Group 3). FINDINGS: Initial stiffness was highest in Group 1 followed by Group 2 and Group 3, being significantly different between Group 1 and Group 3 (p = 0.020). Displacement after 5000 cycles was biggest in Group 3, followed by Group 2 and Group 1, with significant differences between Group 3 and both Group 1 and Group 2 (p ≤ 0.027). Cycles to failure were highest in Group 3 followed by Group 1 and Group 2, being significantly different between Group 2 and Group 3 (p = 0.004). INTERPRETATION: Low-profile 2.0/2.0 dual plates demonstrated similar initial stiffness compared with single 3.5 mm locking plates, however, they revealed significantly lower resistance to failure. Moreover, low-profile 2.5/2.0 dual plates demonstrated significantly higher initial stiffness and similar resistance to failure compared with single 3.5 mm locking plates and can therefore be considered as their useful alternative for diaphyseal clavicle fracture fixation.


Clavicle , Fractures, Bone , Biomechanical Phenomena , Bone Plates , Clavicle/surgery , Fracture Fixation, Internal , Fractures, Bone/surgery , Humans
16.
Eur J Trauma Emerg Surg ; 48(5): 3683-3691, 2022 Oct.
Article En | MEDLINE | ID: mdl-34984496

INTRODUCTION: Definitive treatment of distal extra-articular fractures of the tibia is challenging and both minimal invasive plate osteosynthesis (MIPO) and intramedullary nailing (IMN) are considered to be feasible surgical modalities with their own implant-specific merits and demerits. This retrospective study was designed to compare MIPO versus IMN in terms of fracture healing, complications, functional and radiological outcomes and to assess the efficacy of intra-operative alignment control to reduce the rate of malalignment after definitive fixation of distal extra-articular fractures of the tibia. MATERIALS AND METHODS: All consecutive adult patients with extra-articular distal meta- or diaphyseal tibia fractures that were treated between January 2012 and September 2019 either with MIPO or IMN were included. Outcome measures included fracture healing, complications (infection, malalignment, subsequent surgeries), functional and radiological outcomes. Intra-operative alignment control encompassed bilateral draping of the lower extremities. RESULTS: A total of 135 patients were included out of which 72 patients (53%) were treated with MIPO and 63 patients (47%) underwent IMN. There was a significantly higher incidence of non-union for fractures treated with IMN (13 (22%) vs. 4 (6%), p = 0.04). There was no significant difference between both groups in terms of rotational malalignment (3% vs. 10%) and angular malalignment (4% vs. 5%). A significantly higher rate of infection was found after MIPO after correction of significant differences in baseline characteristics. No differences were found in subsequent surgeries or functional outcomes. CONCLUSION: Both MIPO and IMN are reliable surgical techniques. IMN is associated with higher rates of non-union, whereas MIPO results in a higher risk for infection. The incidence of malalignment was surprisingly low endorsing the utility of the intra-operative alignment control.


Ankle Fractures , Fracture Fixation, Intramedullary , Tibial Fractures , Adult , Ankle Fractures/surgery , Bone Plates/adverse effects , Fracture Fixation, Internal/methods , Fracture Fixation, Intramedullary/methods , Fracture Healing , Humans , Minimally Invasive Surgical Procedures/methods , Retrospective Studies , Tibia/injuries , Tibial Fractures/diagnostic imaging , Tibial Fractures/surgery , Treatment Outcome
17.
Eur J Trauma Emerg Surg ; 48(1): 47-59, 2022 Feb.
Article En | MEDLINE | ID: mdl-33452548

PURPOSE: There is no consensus on the optimal operative technique for humeral shaft fractures. This meta-analysis aims to compare minimal-invasive plate osteosynthesis (MIPO) with nail fixation for humeral shaft fractures regarding healing, complications and functional results. METHODS: PubMed/Medline/Embase/CENTRAL/CINAHL were searched for randomized clinical trials (RCT) and observational studies comparing MIPO with nailing for humeral shaft fractures. Effect estimates were pooled across studies using random effects models and presented as weighted odds ratio (OR), risk difference (RD), mean difference (MD) and standardized mean difference (SMD) with corresponding 95% confidence interval (95%CI). Analyses were repeated stratified by study design (RCTs and observational studies). RESULTS: A total of 2 RCTs (87 patients) and 5 observational studies (595 patients) were included. The effects estimated in observational studies and RCTs were similar in direction and magnitude for all outcomes except operation duration. MIPO has a lower risk for non-union (RD 7%; OR 0.2, 95% CI 0.1-0.5) and re-intervention (RD 13%; OR 0.3, 95% CI 0.1-0.8). Functional shoulder (SMD 1.0, 95% CI 0.2-1.8) and elbow scores (SMD 0.4, 95% CI 0-0.8) were better among patients treated with MIPO. The risk for radial nerve palsy following surgery was equal (RD 2%; OR 0.6, 95% CI 0.3-1.2) and nerve function recovered spontaneously in all patients in both groups. No difference was detected with regard to infection, time to union and operation duration. CONCLUSION: MIPO has a considerable lower risk for non-union and re-intervention, leads to better shoulder function and, to a lesser extent, better elbow function compared to nailing. Although nailing appears to be a viable option, the evidence suggests that MIPO should be the preferred treatment of choice. The learning curve of minimal-invasive plating should, however, be taken into account when interpreting these results.


Fracture Fixation, Intramedullary , Humeral Fractures , Bone Plates , Fracture Fixation, Internal , Humans , Humeral Fractures/surgery , Humerus , Minimally Invasive Surgical Procedures , Observational Studies as Topic , Randomized Controlled Trials as Topic , Treatment Outcome
18.
Eur J Trauma Emerg Surg ; 48(3): 1649-1662, 2022 Jun.
Article En | MEDLINE | ID: mdl-33900417

PURPOSE: Temporary spanning plate fixation of the wrist has been described as an alternative treatment method for complex distal radius fractures (DRfs). This systematic review aims to gain insight on clinical and radiological outcomes of this technique currently published in literature. METHODS: A comprehensive literature search of Pubmed, Embase, CENTRAL and CINAHL databases was conducted on November 5th 2020. All studies reporting on complications, functional, patient-rated and radiological outcomes of temporary spanning plate wrist fixation of DRFs in adult patients were included. RESULTS: Two prospective and eight retrospective cohort studies were included encompassing 353 patients with of 357 DRFs. The overall mean age was 53 years (range 19-95 years). Overall mean follow-up ranged from 6 months to 8.8 years. The union rate was 99.4%. Plate removal was performed on average 4.5 months after initial operation (range 1.1-28.9 months). The most frequently reported complication was implant failure with an incidence of 3.1%. Mean flexion/extension, pronation/supination and radial/ulnar inclination arc averaged 96.6°, 151.5° and 36.5°, respectively. Grip strength averaged 79.7% of the contralateral side. Mean DASH and PRWE scores were 22.9 and 16 points, respectively. Radiological indices were all within the acceptable limits. CONCLUSIONS: Temporary spanning plate wrist fixation is a safe method for the treatment of complex DRFs. This technique can exploit the advantages of temporary wrist immobilization without the disadvantages of external fixation. With these aspects in mind, the spanning plate can serve as a valuable tool in the treatment of complex intra-articular DRFs.


Radius Fractures , Adult , Aged , Aged, 80 and over , Bone Plates , Fracture Fixation, Internal/methods , Humans , Middle Aged , Prospective Studies , Radius Fractures/diagnostic imaging , Radius Fractures/surgery , Range of Motion, Articular , Retrospective Studies , Treatment Outcome , Wrist , Young Adult
19.
Eur J Trauma Emerg Surg ; 48(3): 2477-2482, 2022 Jun.
Article En | MEDLINE | ID: mdl-34625816

PURPOSE: In most hospitals, acquiring postoperative X-rays after operative treatment of a fracture is the standard. Its value, however, after operative treatment for clavicular fractures is questionable. The aim of this study was to evaluate how often there is a change in treatment plan due to the postoperative X-ray after operative treatment of clavicular fractures when intra-operative images were acquired. METHODS: This was a retrospective cohort study performed in a level I trauma center. All consecutive patients treated surgically for clavicular fractures between 2014 and 2018 were included. The primary outcome was any deviation from the standard postoperative protocol resulting from the routine postoperative X-ray taken within the first 72 h after surgery. Secondary outcomes included all other complications and re-interventions performed during follow-up of patients with at least 6-month follow-up. RESULTS: In total, 241 patients were included in the study with a mean age of 42 years (SD 17). Only one patient had an abnormality on postoperative X-ray necessitating additional CT-scanning. No additional re-interventions or deviations from standard postoperative protocol were required. For secondary analyses, 187 patients were available. Seven patients had a late implant associated infection: one was detected at the time of implant removal and six during revision for non-union. Six patients had aseptic complications: four with non-union and two with implant failure. One-hundred and seven patients had an implant removal due to irritation after consolidation. CONCLUSION: Routinely performing postoperative X-rays after osteosynthesis for clavicular fractures seems unnecessary. Refraining from performing unnecessary radiographs will decrease exposure to radiation and likely have a beneficial effect on costs, length of hospital stay as well as healthcare consumption. This study was performed in a single center; therefore, it remains to be seen whether the findings are reproducible in another setting.


Bone Plates , Fractures, Bone , Adult , Bone Plates/adverse effects , Clavicle/diagnostic imaging , Clavicle/injuries , Clavicle/surgery , Fracture Fixation, Internal/methods , Fractures, Bone/complications , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Humans , Postoperative Complications/diagnostic imaging , Postoperative Complications/etiology , Retrospective Studies , Treatment Outcome , X-Rays
20.
Eur J Trauma Emerg Surg ; 48(3): 2369-2377, 2022 Jun.
Article En | MEDLINE | ID: mdl-34185106

OBJECTIVE: Minimal invasive temporary spanning plate (SP) fixation of the wrist has been described as an alternative treatment method in complex distal radius fractures (DRFs). The purpose of this study is to conduct an outcome analysis of all consecutive DRFs treated by SP fixation representing the so far largest published patient cohort outside the United States. METHODS: Indication for SP fixation include DRFs with severe metaphyseal comminution, radiocarpal fracture dislocations with concomitant ligamentous injuries and very distal intra-articular fractures lacking the possibility of adequate plate anchoring. All consecutive patients undergoing SP fixation of DRFs were prospectively included in a single level I trauma centre between 01/01/2018 and 31/12/2020. For functional and patient-rated outcome analysis only patients who completed the 12 month follow-up were included. RESULTS: In the mentioned timeframe, a total of 562 DRFs were treated operatively of which 28 underwent SP fixation. Average age was 58.1 years (range 22-95 years). The fracture type ranged from AO/OTA type B1.1 to C3.3 and included 8 fracture dislocations. SP removal was performed on average 3.7 months after the initial operation (range 1.4-6.5 months). Twenty-five patients completed the 12 month follow-up (mean 14.5 months, range 12-24). Radiological evidence of fracture healing appeared on average 9.9 weeks (range 5-28 weeks) after the initial operation. One patient experienced asymptomatic non-union. Mean radial inclination, volar tilt and ulnar variance at 1 year were all within the acceptable limit predictive of symptomatic malunion. Complications included two patients with tendon rupture and one patient with extensor tendon adhesions needing tenolysis at the time of plate removal leaving an overall complication rate of 12%. There was no implant failure and no infection. Mean satisfaction score was 8.3 (range 4-10) and mean visual analogue scale for resting pain was 0.8 (range 0-5). The mean PRWE score was 17.9 (range 0-59.5) and the mean DASH score was 16.6 (range 0-60.8). Grip strength averaged 23 kg (range 4-74 kg) amounting to 68% of the opposite side. Range of motion regarding the extension/flexion, radial/ulnar abduction and pronation/supination arc reached 72%, 77% and 95% compared to the unaffected side, respectively. CONCLUSIONS: The radiological, functional and patient-rated outcomes in this study are remarkably good considering the complexity of the included fractures. Therefore, this method represents a valuable alternative for the treatment of complex DRFs in selected patients.


Fracture Dislocation , Radius Fractures , Adult , Aged , Aged, 80 and over , Bone Plates/adverse effects , Cohort Studies , Fracture Dislocation/diagnostic imaging , Fracture Dislocation/surgery , Fracture Fixation, Internal/methods , Humans , Middle Aged , Prospective Studies , Radius Fractures/diagnostic imaging , Radius Fractures/surgery , Range of Motion, Articular , Treatment Outcome , Young Adult
...