1.
Microsc Res Tech ; 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38988203

RESUMEN

The aim of this study was to compare of four different nickel-titanium (Ni-Ti) endodontic files and evaluate in terms of cyclic fatigue resistance and metallurgical properties. Four different type Ni-Ti root canal files Protaper Next X2 (PTN) (Dentsply Maillefer, Ballaigues, Switzerland), One Curve (OC) #25.06 (Micro Mega, Besancon, France), EndoPlus Flex Plus Gold X2 (EPG) (Turkuaz Dental, Denizli, Turkey), and EndoPlus Flex Plus Blue #25.06 (EPB) (Turkuaz Dental, Denizli, Turkey) files were tested for cyclic fatigue resistance (n = 20). During experiments artificial zirconia block canal was used. The artificial canal designed with curvature 60° and 5-mm radius. The number of cyclic to fracture (NCF) was noted. Fractured length (FL) parts of Ni-Ti files were recorded to assessment of fracture volumetric point. All fractured surfaces of Ni-Ti files were assessed by scanning electron microscope (SEM) to confirm the type of fractures. Descriptive evaluation become accomplished for the fundamental composition of units with the aid of using energy-dispersive x-ray spectroscopy (EDX). NCF data were evaluated via Bonferroni test with post hoc multiple comparison method. OC showed the highest NCF values (p < .05). The standardization of the study was confirmed as the FL of files was statistically similar in length (p > .05). SEM analysis confirmed that all scanned samples were fractured due to cyclic fatigue. EDX analysis confirmed that EPB established the poorest Ni content file. RESEARCH HIGHLIGHTS: The cyclic fatigue-related failure of One Curve was significantly more resistant than Protaper Next and EndoPlus files. Scanning electron microscopy images showed that One Curve and Protaper Next have round tips Energy dispersive x-ray spectroscopy showed that all four endodontic instruments mainly have Nickel and Titanium elements.

2.
J Endod ; 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38964675

RESUMEN

INTRODUCTION: This study aimed to evaluate the dynamic cyclic fatigue resistance of Reciproc® Blue files subjected to brushing motion. METHODS: Twenty Reciproc® Blue files (R25, VDW, Munich, Germany) were employed for chemical-mechanical preparation in root canals of 3D printed replicas of mandibular molars. The instruments were divided into two groups (n=10): Group BM, instrumentation with brushing motions; Group WBM, instrumentation without brushing motions. Subsequently, the same instruments underwent cyclic fatigue testing using artificial canals consisting of a stainless-steel plate and an apical segment with a 45° curvature. Data regarding the time to fracture, number of cycles to fracture (NCF), and length of the fractured fragment were collected and subjected to statistical analysis using the t-test or Mann-Whitney test, with a significance level of 5%. Additionally, the fractured fragments were examined under a scanning electron microscope. RESULTS: No statistical differences were observed between the groups in terms of time to fracture (p<0.05), NCF (p<0.05), and length of the fractured fragment (p<0.05). CONCLUSION: The brushing motion did not affect the dynamic cyclic fatigue resistance of Reciproc Blue files.

3.
J Conserv Dent Endod ; 27(4): 393-399, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38779209

RESUMEN

Background: This study aimed to compare the effect of heat treatment on the cyclic fatigue resistance of three different nickel-titanium rotary file systems: TruNatomy, HyFlex CM, and NeoEndo flex in simulated curved canals at two different radii of curvatures. Materials and Methods: A total of 60 NiTi rotary files of three types were used, and the samples were divided into three groups TruNatomy, HyFlex CM, and NeoEndo flex. All the instruments were subjected to cyclic fatigue testing using a stainless steel custom-made canal model with a 60° angle of curvature and two radii of curvature 5 mm and 3 mm; the number of cycles to fracture and length of the fractured segment was measured. The separated instruments were subjected to fractographic analysis under scanning electron microscope. Results: The number of cycles to failure to fracture a file at a 3 mm radius of curvature is significantly less as compared to a 5 mm radius of curvature (HCM > TRN > NE). Conclusion: Within the limitation of the present study, there was a positive correlation between the radius of curvature and fatigue life of NiTi files.

4.
Materials (Basel) ; 17(10)2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38793413

RESUMEN

The resistance of nickel-titanium endodontic instruments against cyclic fatigue failure remains a significant concern in clinical settings. This study aimed to assess the cyclic fatigue strength of five nickel-titanium rotary systems, while correlating the results with the instruments' geometric and metallurgical characteristics. A total of 250 new instruments (sizes S1/A1, S2/A2, F1/B1, F2/B2, F3/B3) from ProTaper Gold, ProTaper Universal, Premium Taper Gold, Go-Taper Flex, and U-Files systems underwent mechanical testing. Prior to experimental procedures, all instruments were meticulously inspected to identify irregularities that could affect the investigation. Using a stereomicroscope, design characteristics such as the number of spirals, length, spirals per millimeter, and average helical angle of the active blade were determined. The surface finishing characteristics of the instruments were examined using a scanning electron microscope. Differential scanning calorimetry was employed to establish the instruments' phase transformation temperatures, while energy-dispersive X-ray spectroscopy was utilized to analyze the elemental composition of the alloy. The instruments were subjected to cyclic fatigue testing within a stainless steel non-tapered artificial canal featuring a 6 mm radius and 86 degrees of curvature. Appropriate statistical tests were applied to compare groups, considering a significance level of 0.05. The assessed design characteristics varied depending on the instrument type. The least irregular surface finishing was observed in U-Files and Premium Taper Gold files, while the most irregular surface was noted in Go-Taper Flex. All instruments exhibited near-equiatomic proportions of nickel and titanium elements, whereas ProTaper Universal and U-Files instruments demonstrated lower phase transformation temperatures compared to their counterparts. Larger-sized instruments, as well as ProTaper Universal and U-Files, tended to display lower cyclic fatigue strength results. Overall, the design, metallurgical, and cyclic fatigue outcomes varied among instruments and systems. Understanding these outcomes may assist clinicians in making more informed decisions regarding instrument selection.

5.
Saudi Dent J ; 36(4): 656-660, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38690374

RESUMEN

Introduction: Comparative evaluation of the newly introduced; RACE EVO file system to the currently well-performing file systems like HyFlex EDM OneFile, Vortex Blue, ProTaper Gold (PTG) with regards to the cyclic fatigue resistance. Materials: &Methods.The endodontic rotary files under evaluation were segregated into four groups as follows:; RACE EVO, PTG, Vortex Blue, and HyFlex EDM OneFile. A detailed physical analysis of the cyclic fatigue resistance was performed in 15 files of each type (n = 60). Under the test conditions of 37 °C the test samples were subjected to continuous motion at the manufacturer recommended speed within an artificial curved canal until it fractured. For all the test samples, with the recording of time of fracture, calculation was done for number of cycles to fracture (NCF). In addition, the length of the fractured segment was determined. The fractured surface was further evaluated with scanning electron microscopic (SEM) images. Results: Highest significance for NCF was seen in HyFlex EDM OneFile followed by the Vortex Blue, PTG, and; RACE EVO (p < 0.05) by analyzing the data statistically. Significant differences among the lengths of the fractured segments were evident among tested files, ranging between 4.73 and 6.3 mm (p < 0.05) with HyFlex EDM OneFile uniquely differentiating from the others showing the fracture at 6.3 mm. The common features of cyclic fatigue failure was further substantiated by SEM images. Conclusions: Compared to the HyFlex EDM OneFile, Vortex Blue, and PTG files; RACE EVO demonstrated significantly lower resistance to cyclic fatigue.

6.
PeerJ ; 12: e17418, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38799069

RESUMEN

Aim: Assess the effect of simulated clinical use and sterilization on the cyclic fatigue resistance of Race Evo and Tia Tornado Blue nickel titanium (NiTi) files. Materials and Methods: For this study, a total of sixty-four NiTi files were selected, with thirty-two files each from two different manufacturers. Files from each manufacturer were subdivided into four subgroups (n = 8) based on the test parameters. The control groups included files that were neither used nor sterilized. Files from the test groups were used to prepare the root canals of extracted mandibular premolars and then sterilized. This procedure was repeated once, twice, or thrice, depending on the test group. All files were then subjected to a cyclic fatigue test. Data was statistically analyzed using the Kruskal-Wallis and Mann-Whitney U tests. Results: No significant difference was observed in the number of cycles to failure (NCF) among the subgroups for both types of files (P = 0.869 for Tia Tornado Blue, P = 0.626 for Race Evo). Tia Tornado Blue files displayed significantly higher NCF values in the control (P = 0.021), once (P = 0.027), and thrice (P = 0.031) usage groups when compared to Race Evo files. Conclusions: Repeated clinical use and sterilization for up to three cycles did not affect the cyclic fatigue resistance of Race Evo and Tia Tornado Blue files.


Asunto(s)
Níquel , Esterilización , Titanio , Esterilización/métodos , Humanos , Falla de Equipo , Ensayo de Materiales , Preparación del Conducto Radicular/instrumentación
7.
Bioengineering (Basel) ; 11(5)2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38790365

RESUMEN

INTRODUCTION: Modern endodontics aims to decrease the bacterial load from the complex endodontic space. Over the years, improvements in the operative phases have led to a considerable increase in the success rate of endodontic treatments. The shaping phase has seen the development of new techniques supported by technological innovations that have led to higher treatment predictability. Endodontic instruments have experienced a series of changes that have led to modifications in their design, surface treatments, and heat treatments. The clinical use of rotating nickel-titanium instruments has become widespread and consolidated, a success due primarily to the alloy's mechanical characteristics, which are superior to steel ones, but also to innovations in instrument design. The advent of the Ni-Ti alloy has kept the concepts and requirements of shaping the same but has modified its implementation in endodontics. AIM: The following review followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) protocol. The research question focused on Ni-Ti endodontic instruments whose cyclic fatigue was evaluated by analyzing cyclic fatigue strength and the incidence of fracture. RESULTS: At the end of the research, 10 systematic reviews and 1 randomized controlled trial were included in this comprehensive review. The most frequently analysed alloys were M-wire, conventional Ni-Ti, and CM-wire. In seven articles, instruments made of M-wire alloy were used; in eight articles, instruments made of conventional Ni-Ti; and in seven articles, instruments made of CM-wire alloy. CONCLUSIONS: The technological evolution of Ni-Ti alloys has led to the development of increasingly high-performance endodontic files that are resistant to cyclic fatigue during clinical practice and have greater resistance to sterilisation practices, making treatment easier and more predictable over time. In particular, heat-treated nickel-titanium root canal instruments present greater resistance to cyclic fatigue than untreated ones and those used with reciprocating kinematics concerning continuous rotation.

8.
J Endod ; 50(7): 1011-1016, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38642733

RESUMEN

INTRODUCTION: The purpose of this study was to evaluate the effect of side flattening of cutting flutes on the cyclic resistance and torsional resistance of nickel-titanium files. METHODS: Both novel flattened Platinum V.EU (PL) and standard nonflattened CC Premium V.EU (CC) rotaries were tested. For cyclic fatigue tests, all the files were rotated in an artificial root canal with a curvature of 45° and a radius of 6.06 mm at 300 rpm (n = 15 in each group). The number of cycles to failure (NCF) was calculated. For torsional tests, the files were rotated at 2 rpm clockwise until fracture occurred. The maximum torque value at fracture was measured and the toughness and distortion angle were computed. Subsequently, 5 fragments were randomly selected in each experiment, the cross-section and longitudinal direction of the fragments were photographed using a scanning electron microscope. An unpaired t-test was performed at a significance level of 95%. RESULTS: There was a statistically significant difference in NCF between CC and PL (P < .05). CC showed higher NCF than PL. There was no statistically significant difference between CC and PL with regards to the parameters related to torsional resistance (distortion angle, ultimate strength, and toughness) (P > .05). CONCLUSION: Within the limitations of this study, side flattening of the file did not improve cyclic resistance or torsional resistance of the files. As side flattening may reduce a file's cyclic resistance, such files should be used with caution in clinical practice.


Asunto(s)
Falla de Equipo , Níquel , Preparación del Conducto Radicular , Titanio , Torsión Mecánica , Preparación del Conducto Radicular/instrumentación , Ensayo de Materiales , Diseño de Equipo , Torque , Microscopía Electrónica de Rastreo , Instrumentos Dentales , Aleaciones Dentales/química
9.
J Pharm Bioallied Sci ; 16(Suppl 1): S254-S257, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38595510

RESUMEN

Background: Maxillary molar endodontic treatments require the right post and core system. This study tested cast metal, glass fiber with composite resin, carbon fiber with composite resin, and zirconia post and core materials. Materials and Methods: Sixty removed human maxillary teeth were randomly divided into four post and core material groups (n = 15 per group). The teeth acquired their post and core system after normal endodontic treatment. Fracture resistance, cyclic fatigue resistance, and microleakage analyses were statistically assessed. Results: The zirconia post and core material had the highest fracture resistance (mean: 900 N), followed by carbon fiber with composite resin, cast metal, and glass fiber with composite resin. Zirconia had the highest mean cycles to failure (120,000), followed by carbon fiber with composite resin (100,000), cast metal (110,000), and glass fiber with composite resin (90,000). Zirconia had the lowest mean microleakage score (1.8), and glass fiber with composite resin, the highest (3.0). Conclusion: The zirconia post and core material outperformed the others in fracture resistance, cyclic fatigue resistance, and sealing. The cast metal has better fracture and cycle fatigue resistance than glass fiber with composite resin. These findings help doctors choose maxillary molar endodontic post and core materials.

10.
J Funct Biomater ; 15(4)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38667542

RESUMEN

This in vitro study aims to assess the cyclic fatigue resistance of the Protaper Ultimate (PTU) files compared to the Protaper Gold (PTG) and the M3 UDG (M3) files using various motion kinematics in simulated canals. As far as the authors are aware, no study has previously compared the three file systems before this current investigation. Therefore, closing this information gap is the goal of the current research. Methods: A total of (60 new endodontic files were randomly divided into 6 groups (10 files per group); groups 1, 3, and 5 used continuous rotation (CR), while groups 2, 4, and 6 used forward reciprocating motion (FRM). A manufactured stainless-steel artificial canal was used to perform the cyclic fatigue testing. The results were analyzed using Student's t-test and two-way ANOVA. All pairwise comparisons revealed statistically significant differences in the time to failure (TTF) for every study group (p < 0.001), with the exception of the PTG and M3 files, which performed similarly using both CR and FRM. Conclusions: The PTU files performed better than the PTG and M3 files in terms of the TTF and number of cycles to failure (NCF) using both CR and FRM.

11.
Materials (Basel) ; 17(3)2024 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-38591373

RESUMEN

The aim of this study was to assess the effect of body temperature (37 °C) on the cyclic fatigue resistance of three endodontic single-file systems using a new testing setup. One Shape® new generation (OS), WaveOne™ (WO) and WaveOne® GOLD (WOG), which are made from different NiTi alloys and operated in different motions (rotation/reciprocation), were evaluated. The study design included four groups. Each group comprised 30 files, 10 files of each of the three file systems, tested at 20 ± 2 °C (group 1 and 3) and at 37 ± 1 °C (group 2 and 4). All files were tested in a custom-made metal block with artificial canals of 60° angle, and a 5 mm and 3 mm radius of curvature, respectively. A heating element was attached to replicate a temperature of 37 °C. Files were introduced 18 mm into the canals and operated until failure. Transformation temperatures of five samples of each of the tested file systems were determined via the bend and free recovery (BFR) method. With the exception of WOG in canals with a 3 mm radius of curvature (p = 0.075), all the tested file systems showed statistically significantly less time needed to fracture when operated at 37 ± 1 °C compared to at 20 ± 2 °C in canals with a 5 mm and 3 mm radius of curvature using Mann-Whitney U test (p < 0.05). All file systems showed transformation temperatures below the body temperature. We concluded that body temperature directly affects the cyclic fatigue resistance of all tested file systems. Bend and free recovery can be suitable for the determination of austenite finish temperatures (Af) of endodontic instruments as it allows testing a longer portion of the instrument.

12.
Int Dent J ; 74(4): 855-861, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38350803

RESUMEN

OBJECTIVE: This is the first study evaluating the impact of different pecking motion depths on dynamic cyclic fatigue resistance of different endodontic instruments. METHODS: Four nickel-titanium systems (Hyflex EDM OneFile 25/. ∼; Rotate 25/0.6; Mtwo 25/0.6; Reciproc Blue R25) were tested. Forty instruments from each group were subjected to 4 different pecking movements to evaluate their cyclic fatigue resistance. The distances for the pecking motion were 3-mm forward and backward, 1-mm (3-mm forward and 2-mm backward), 2-mm (4-mm forward and 2-mm backward), and 3-mm (5-mm forward and 2-mm backward). Speeds were 100 and 200 mm/min for the descending and ascending motion, respectively. The times to fracture (TtF) in seconds were recorded for each instrument. Data were statistically analysed by using 2-way ANOVA and Bonferroni multiple comparison post hoc test (P < .05). RESULTS: All instruments had a significant increase in cyclic fatigue resistance during the forward dynamic motion compared with the axial continuous. Overall, the heat-treated instruments reported higher fatigue strength than the untreated files (P < .05). Reciproc Blue and Hyflex EDM showed higher TtF in the forward movements of 1-/2-mm and 2-mm (P < .05), respectively while Mtwo 25.06 and Rotate 25.06 in the forward movement of 3-mm (P < .05). CONCLUSIONS: Within the limits of this in vitro study, the pecking motion depths had varying impacts on the cyclic fatigue resistance of instruments. Reciproc Blue and Hyflex EDM performed significantly better with pecking motions of 1-and 2-mm. Improving endodontic instrument durability through specific pecking depths has the potential for improving clinical performance and reducing instrument failures.


Asunto(s)
Falla de Equipo , Ensayo de Materiales , Preparación del Conducto Radicular , Técnicas In Vitro , Preparación del Conducto Radicular/instrumentación , Instrumentos Dentales , Titanio , Diseño de Equipo , Níquel , Movimiento (Física) , Análisis del Estrés Dental , Humanos , Estrés Mecánico
13.
J Endod ; 50(4): 520-526, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38311116

RESUMEN

INTRODUCTION: This study aimed to evaluate the effects from the memory-triple (MT) heat treatment on the fatigue resistance of the Reciproc by comparison with the file systems of same geometry. METHODS: Reciproc files subjected to MT heat treatment technology were designated as Group RMT and were compared with the original Reciproc (Group REC) and Reciproc Blue (Group REB). Each NiTi file from 3 groups (n = 15) was operated reciprocally with a repetitive up-and-down movement in the curved canal with 4 mm of pecking distance inside of the simulated canal at body temperature. When each file fractured, the time until fracture was recorded. The length of the fractured fragment was measured. Fractured fragments were observed under scanning electron microscope (SEM) to evaluate the topographic features of the surface. Differential scanning calorimetry (DSC) analysis was performed to estimate phase transformation temperatures. One-way analysis of variance and Duncan post hoc comparison were applied to compare among the groups at a significance level of 95%. RESULTS: RMT showed significantly higher fracture resistance (P < .05), whereas there was no difference in fatigue resistance between REC and REB. SEM examination showed the files from the 3 groups had similar topographic features. RMT showed a peak of austenite peak (Ap) at a temperature (52°C) higher than body temperature, whereas REC and REB showed Ap at 37 and 32°C, respectively. CONCLUSIONS: Under the condition of this study, the new heat treatment technique of MT technology could enhance the fatigue fracture resistance of the reciprocating files made of M-wire and Blue-wire.


Asunto(s)
Calor , Preparación del Conducto Radicular , Falla de Equipo , Estrés Mecánico , Instrumentos Dentales , Ensayo de Materiales , Diseño de Equipo , Titanio
14.
Bull Tokyo Dent Coll ; 65(1): 1-9, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38355115

RESUMEN

The present study investigated the cyclic fatigue properties of titanium alloys (Ti-6Al-4V and Ti-6Al-7Nb) as implant materials and compared their properties with those of commercially pure titanium. Ti-6Al-4V and Ti-6Al-7Nb cylinders with diameters of 3.0 mm were examined. The surfaces of the cylinders were roughened by sand blasting with alumina particles and acid etching. Static and cyclic tests were performed according to ISO 14801:2016. The yield force in the static test (YS) was measured in 5 specimens of each alloy using a universal testing machine. The yield force in a cyclic test (YC) was measured in 20 specimens of each alloy using the staircase method, which involved applying a cyclic load at a frequency of 10 Hz for 106 cycles. After the cyclic loading tests, cross-sections of the specimens were examined under an optical microscope. The YS values for Ti-6Al-4V and Ti-6Al-7Nb were 1463 N±93 N and 1405 N±79 N, respectively, and the YC values were 870 N±58 N and 853 N±202 N, respectively. Microscopic observation revealed cracks on the tensile side of some of the specimens, including run outs and failures. The results of this study suggest that the YC values for Ti-6Al-4V and Ti-6Al-7Nb were 40% less than those for YS. The yield force of Grade-4 Cp-Ti significantly decreased after cyclic loading. The YC values for Ti-6Al-4V and Ti-6Al-7Nb were approximately 900 N, which was markedly greater than that for commercially pure, Grade-4 titanium (700 N).


Asunto(s)
Aleaciones , Implantes Dentales , Titanio , Materiales Dentales , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Ensayo de Materiales , Aleaciones Dentales
15.
J Conserv Dent Endod ; 27(1): 95-99, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38389747

RESUMEN

Aims: The aim of this in vitro study was to compare the cyclic fatigue resistance of three different endodontic nickel-titanium rotary instruments using a dynamic testing device. Materials and Methods: Ten files each of ProTaper Gold (PG), Hyflex Electro-discharge Machining (HEDM), and TruNatomy (TN) were tested in a custom-fabricated dynamic cyclic fatigue testing device at 60° curvature having a radius of curvature of 5 mm. The number of cycles to the fracture (NCF) of each instrument was calculated and three continuous groups were compared by the Kruskal-Wallis test and Dunn post hoc test was used for pairwise comparison. Results: Cyclic fatigue resistance of HEDM was the highest, followed by TN. PG had the lowest among the three. Conclusion: Within the limitations of the present in vitro results, it can be concluded that HEDM files appeared to be suitable for shaping complex canals with the greater number of cycles before it fractures.

16.
Cureus ; 16(1): e52916, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38406139

RESUMEN

Background This study aims to analyze the phase transformation behavior and evaluate the effect of different temperatures on the fracture strength of files. Methodology A total of 108 files were used, and cyclic fatigue tests were performed on HyFlex EDM, VDW.ROTATE, and TruNatomy at three different temperatures (+4°C, +35°C, and +60°C) The time to fracture of files was measured, and the number of cycles was calculated. In addition, the fractured fragment lengths were measured. The Kruskal-Wallis test was used to compare the data that were not normally distributed according to groups. The Mann-Whitney U test was performed for comparisons. P-values <0.05 were considered statistically significant. Results As the temperature increased for all files, the number of cycles to fracture (NCF) decreased. NCF was significantly higher for ROTATE at 4°C and 60°C and HyFlex EDM at 35°C. Conclusions The resistance to cyclic fatigue in all files decreased significantly as the temperature increased.

17.
Clin Oral Investig ; 28(2): 149, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38355823

RESUMEN

OBJECTIVE: The study aims to evaluate the shear bond and flexural strength fatigue behavior of yttrium-stabilized zirconia (4YSZ) repaired using different resin composites. MATERIALS AND METHODS: Cylindric specimens of 4YSZ were obtained for the bond strength (Ø = 6 mm, 1.5 mm of thickness) and biaxial flexural strength (Ø = 15 mm, 1 mm of thickness) fatigue tests and divided into 3 groups according to the repair resin composite: EVO (nanohybrid), BULK (bulk-fill), and FLOW (flowable). The zirconia surface was air-abraded with alumina particles, a 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) primer was applied, and the resin composite was build-up over the zirconia. Fatigue shear bond strength and flexural fatigue strength tests were performed (n = 15). One-way ANOVA and Tukey post hoc tests were carried out for both outcomes, besides scanning electron microscopy and finite element analysis. RESULTS: The repair material affected the fatigue shear bond strength of zirconia ceramic. The BULK group (18.9 MPa) depicted higher bond strength values than FLOW (14.8 MPa) (p = 0.04), while EVO (18.0 MPa) showed similar results to both groups. No effect was observed for the mechanical behavior (p = 0.53). The stress distribution was similar for all groups. CONCLUSION: The repair of yttrium-stabilized zirconia (4YSZ) ceramics with bulk-fill resin composites was the best option for high fatigue bond strength. However, the fatigue mechanical performance was similar regardless of the applied repair material. CLINICAL RELEVANCE: The repair of yttrium-stabilized zirconia (4YSZ) monolithic restorations may be performed with nanohybrid and bulk-fill resin composites in order to promote longevity in the treatment.


Asunto(s)
Recubrimiento Dental Adhesivo , Metacrilatos , Recubrimiento Dental Adhesivo/métodos , Propiedades de Superficie , Ensayo de Materiales , Resinas Compuestas/química , Circonio/química , Cerámica/química , Resistencia al Corte , Itrio/química , Cementos de Resina/química , Análisis del Estrés Dental
18.
J Clin Med ; 13(3)2024 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-38337577

RESUMEN

(1) Background: The failure of nickel-titanium (NiTi) rotary files is a complication related to endodontic instruments. The aim of this study was to compare the resistance to cyclic fatigue between rotary and reciprocating file systems. (2) Methods: Specific PICO: Population (P): artificial root canals; Interventions (I): instrumentation with NiTi rotary and reciprocating files; Comparison (C): rotary versus reciprocating files; Outcome (O): cyclic fatigue resistance. Studies were identified through bibliographic research using electronic databases (Medline, Embase, Scopus, SciELO, and WOS). The studies were combined using a random effects model by the inverse variance method. The effect size was the mean of the time to fracture (TTF) and number of cycles to fracture (NCF). Heterogeneity was assessed using the p value of the Q test for heterogeneity and the I2. (3) Results: TTF for rotary files was determined in 474.5 s and 839.1 for reciprocating without statistically significant differences. NCF for rotary systems was determined in 1444.2 and for reciprocating file systems in 4155.9 with statistically significant differences (p = 0.035), making reciprocating files more resistant. (4) Conclusions: Reciprocating files have better resistance to cyclic fatigue than rotary files. When tested in double curvature canals, reciprocating files also showed higher resistance.

19.
J Endod ; 50(2): 213-219, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37924940

RESUMEN

INTRODUCTION: The aim of this study was to evaluate the torsional resistance, cyclic fatigue resistance, and bending stiffness of nickel-titanium (NiTi) file systems with different heat treatments and cross-sectional designs. METHODS: WaveOne Primary treated with memory-triple (MT) heat treatment (WOMT) was compared with WaveOne Primary (WO) and WaveOne Gold Primary (WOG). Torsional resistance test was performed using a customized device, and the distortion angle, ultimate strength, and toughness were evaluated. For cyclic fatigue resistance test, the instruments were reciprocated with continuous 4 mm up-and-down movement until fracture in a customized device, and the time to fracture was compared. Fracture surfaces of each group were examined under the scanning electron microscope. Bending stiffness was measured using a custom-made device. The results were analyzed using one-way analysis of variance and the Tukey's post hoc comparison at a significance level of 95%. RESULTS: WOMT showed higher ultimate strength and toughness than the other systems (P < .05). WOMT also showed highest cyclic fatigue resistance among the tested groups (P < .05). WO had the highest bending stiffness than others, whereas WOMT had a larger residual angle than others (P < .05). CONCLUSIONS: This new MT heat treatment technique makes NiTi file more flexible and improves its mechanical properties. In addition, the effect of heat treatment on flexibility was found to be more significant than that of the cross-sectional area.


Asunto(s)
Aleaciones , Calor , Titanio , Níquel , Instrumentos Dentales , Diseño de Equipo , Preparación del Conducto Radicular , Estrés Mecánico , Ensayo de Materiales , Torsión Mecánica
20.
Clin Exp Dent Res ; 10(1): e811, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38053521

RESUMEN

OBJECTIVES: The aim of this study is to determine the cyclic fatigue resistance of Mtwo Minimal in static and dynamic tests, with different amplitudes of pecking movements, at intracanal temperature. MATERIALS AND METHODS: Two hundred new 25-mm Mtwo Minimal rotary files (#10/0.035, #17.5/0.045, #25/0.05, #40/0.03, #45/0.03) were tested in static and dynamic cyclic fatigue tests at 35°C (±1°C). An artificial stainless-steel canal was used. In the dynamic mode, axial movements were set at 1 and 3 mm. The number of cycles to fracture (NCF) was recorded and statistically analyzed by one-way analysis of variance (p < 0.05). RESULTS: The 3-mm dynamic test showed significantly increased NCF than the other tests for the #10/0.035, #17.5/0.045, and #25/0.05 files (p < 0.05). The #40/0.03 and #45/0.03 files showed no significant differences in all the tests (p > 0.05). CONCLUSION: Mtwo Minimal showed higher cyclic fatigue resistance in the dynamic test than the static test, except for the larger instruments. The 3-mm pecking amplitude increased the cyclic fatigue resistance of the smaller instruments.


Asunto(s)
Níquel , Titanio , Aleaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...