Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.169
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39229644

RESUMEN

PURPOSE: It is common to hear talk of 'responders' and 'non-responders' with respect to myopia control interventions. We consider the reality of distinguishing these sub-groups using data from the first year of the Low-concentration Atropine for Myopia Progression (LAMP) study. METHODS: The first year of the LAMP study was a robustly designed, placebo-controlled trial of three different low concentrations of atropine using a large sample size (N > 100 randomised to each group). The authors subsequently published mean axial elongation and myopia progression rates by age group. We used these data to calculate efficacy in terms of both absolute reduction in myopic progression and absolute reduction in axial elongation for each of the different atropine concentrations at each age group. We then compared these efficacy data to the overall progression for each of the two progression metrics. RESULTS: Plotting efficacy as a function of overall myopia progression and axial elongation for each of the different atropine concentrations demonstrates the invariant nature of efficacy, in terms of clinically meaningful reduction in progression, despite a substantial range of underlying overall progression. That is, faster progressors-the so-called non-responders-achieved similar reduction in axial elongation and myopia progression as the slower progressors-the so-called responders-within the various atropine treatment groups. CONCLUSION: The use of the terms, responders and non-responders, during myopia progression interventions is not supported by evidence. Those designated as such may simply be slower or faster progressors, who, on average achieve the same benefit from treatment.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39244703

RESUMEN

PURPOSE: Given the potential role of light and its wavelength on ocular growth, this study investigated the effect of short-term exposure to red, cyan and blue light on ocular biometry in humans. METHODS: Forty-four young adults and 20 children, comprising emmetropes and myopes, underwent 2-h sessions of cyan (507 nm), red (638 nm) and broadband white light on three separate days via light-emitting glasses. Additionally, young adults were exposed to blue light (454 nm) on an additional day. Axial length (AL) and choroidal thickness (CT) were measured in the right eye before the light exposure (0 min), after 60 and 120 min of exposure and 30 min after light offset using an optical biometer and optical coherence tomographer, respectively. RESULTS: Compared to broadband light, exposure to red light resulted in a significant increase in AL (mean difference between white and red light at 120 min, +0.007 mm [0.002]), but no significant change in CT, while cyan light caused a significant AL reduction (-0.010 mm [0.003]) and choroidal thickening (+0.008 mm [0.002]) in young adults (p < 0.05). Blue light caused a significant decrease of -0.007 mm (0.002) in young adult eyes at 60 min (p < 0.05). In children, cyan light led to a significant reduction in AL (-0.016 mm [0.004]) and strong sustained choroidal thickening (+0.014 mm [0.004]) compared to broadband light at 120 min (p < 0.05). The effects of cyan light on AL and CT were found to be stronger in myopic young adults and emmetropic children. The opposing effects of red and cyan light on ocular biometry were similar between the two age groups (p > 0.05). CONCLUSIONS: Exposure to cyan light resulted in AL reduction and choroidal thickening in both young adults and children. Further research is needed to determine the application of these results in developing interventions for myopia control.

3.
Am J Ophthalmol ; 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39218390

RESUMEN

PURPOSE: To introduce and validate a novel substantially lower-priced and rapid swept-source investigational optical biometer in healthy and cataractous eyes, employing a thermally tuned laser diode used extensively in cell-phones and data communication as an alternative swept-source. DESIGN: Prospective accuracy, validity, and reliability analysis. METHODS: Sixty eyes of 59 subjects (twenty-nine eyes of 29 healthy subjects and thirty-one eyes of 30 cataract patients) were enrolled in a prospective comparative study at the Vienna General Hospital between August 2021 and April 2023. Averaged intraocular distances were acquired in 2.5 seconds from datasets consisting of 5000 consecutive A-scans at a single position by a low-cost swept-source optical biometry (SSOB) system. Instrument repeatability was assessed via standard deviations (SDs) and coefficients of variation (COVs) of parameters such as axial length (AL), anterior chamber depth (ACD), lens thickness (LT), and central corneal thickness (CCT). Healthy subjects and cataract patients were subsequently measured on the same day with the SSOB and a referential partial coherence interferometry (PCI) biometer (IOL Master 500, Zeiss, Jena, Germany) to establish AL inter-device correlation (r) for instrument calibration. AL and ACD as shared parameters between both biometers were evaluated for their limits of agreements (LoA) using Bland-Altman analysis. RESULTS: Repeated measurements of AL, ACD, LT, and CCT revealed SDs of 18 µm, 12 µm, 12 µm, and 10 µm, respectively. All parameters except for CCT had a COV < 1%. Except for 1 eye with white cataract, 59 eyes of 59 study participants with various degrees and types of cataract could be measured with both devices. AL inter-device correlation was excellent (r=>0.99). The 95 % LoAs between both biometers were -0.14 to 0.13 mm for AL and -0.28 to 0.25 mm for ACD. CONCLUSIONS: Optical biometry using a thermally-tunable VCSEL swept source light source has the potential to provide clinically relevant biometric parameters at an unprecedented 100-fold lower price point than currently employed state of the art optical biometers, paving the way for compact devices in remote care settings.

4.
Sci Rep ; 14(1): 20626, 2024 09 04.
Artículo en Inglés | MEDLINE | ID: mdl-39232107

RESUMEN

To compare the corneal biomechanical parameters measured by Corvis ST in subjects with varying degrees of myopia. And the factors that may affect corneal biomechanical properties were also investigated. Participants in this prospective cross-sectional study were classified into three groups according to spherical equivalent (SE) and axial length (AL): Non-myopia (NM, SE > - 0.50 D and AL < 26 mm), Mild-to-moderate myopia (MM, - 6.00 D < SE ≤ - 0.50 D and AL < 26 mm), high myopia (HM, SE ≤ - 6.00 D or AL ≥ 26 mm). Ten corneal biomechanical parameters were finally included. Linear mixed-effects model accounting for using both eyes in the same participant was carried out to evaluate how the corneal biomechanical parameter was influenced by varying degrees of myopia after adjusting for biomechanically corrected intraocular pressure (bIOP) and central corneal thickness (CCT). Further, multiple linear regression was performed to explore the correlation between corneal biomechanical parameter and SE, AL, bIOP or CCT. A total of 304 eyes from 224 healthy myopic subjects were recorded. There were 95 eyes with NM, 122 eyes with MM, and 87 eyes with HM. After adjusting for bIOP and CCT, eyes with high myopia showed shorter highest concavity time (HC-time, p = 0.025), greater peak distance (PD, p = 0.001), greater deflection amplitude (DA-Max, p = 0.002), smaller whole eye movement (WEM-Max, p < 0.001) and reduced stiffness parameter (SP-A1, p < 0.001). Multiple regression analysis showed that five parameters (HC-time, p < 0.001; PD, p < 0.001; DA-Max, p = 0.001; WEM-Max, p < 0.001; and SP-A1, p < 0.001) of Corvis ST were significantly correlated with AL, and one parameter (Corvis biomechanical index, p = 0.016) has significant relationship with SE. With the increase of myopia, significant changes in several corneal biomechanical parameters indicated a progressive decrease in corneal stiffness, independent of bIOP and CCT. Corneal biomechanical parameters may be predictors of scleral mechanical strength in high myopia, which has certain application value in clinical management of myopia.


Asunto(s)
Córnea , Miopía , Humanos , Córnea/fisiopatología , Córnea/patología , Miopía/fisiopatología , Masculino , Femenino , Fenómenos Biomecánicos , Adulto , Estudios Transversales , Estudios Prospectivos , Adulto Joven , Presión Intraocular/fisiología
5.
Am J Ophthalmol ; 2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-39244001

RESUMEN

PURPOSE: Animal models suggest omega-3 polyunsaturated fatty acids (PUFAs) may protect against myopia by modulating choroidal blood perfusion, but clinical evidence is scarce and mixed. We aimed to determine the causality between omega-3 PUFAs and myopia using Mendelian randomization (MR) analysis. DESIGN: Two-sample MR analysis. METHODS: Exposures are genetically predicted 18 fatty acids (FAs) related traits. Spherical equivalent refraction (SER) and axial length were used as measurements of myopia. Genome-wide association study summary data on blood levels of 18 FAs related traits (n=115,006), refractive spherical equivalent (n=351,091), axial length (n=69,945) and choroidal thickness (n=44,823) were sourced from the UK Biobank, the Genetic Epidemiology Research on Adult Health and Aging cohort, and the Consortium for Refractive Error and Myopia Study. We used five MR models and considered results statistically significant if the Bonferroni-corrected P-value was ≤2.78 × 10-3 in at least 3 MR models. The beta represents the change in outcomes (SER in diopter; axial length in mm; choroidal thickness in standard deviation) per standard deviation unit increase in FAs levels. RESULTS: At a Bonferroni-corrected significance, higher levels of omega-3 (Beta, 0.32-0.34), omega-3/total FAs ratio (Beta, 0.31-0.44), docosahexaenoic acid (DHA) (Beta, 0.36-0.46), DHA/total FAs ratio (Beta, 0.37-0.53), PUFAs/total FAs ratio (Beta, 0.07-1.003), and degree of unsaturation (Beta, 0.28-0.44) were associated with a more positive SER, suggesting a lower risk of myopia. Similar trends were observed for axial length albeit with borderline significance (P≤0.035 in ≥2 models). Higher levels of omega-3, DHA, DHA/total FAs ratio, PUFAs/total FAs ratio, PUFAs/monounsaturated FAs ratio, and degree of unsaturation were nominally associated with thicker choroidal thickness (Beta, 0.05-0.13; P≤0.045 in ≥2 models). CONCLUSION: Our multiple MR models suggest a protective effect of omega-3 and DHA on myopia, potentially through modulation of choroidal blood perfusion. Further randomized clinical trials are needed to confirm the effectiveness and determine the optimal dose and duration.

6.
Artículo en Inglés | MEDLINE | ID: mdl-39243285

RESUMEN

OBJECTIVE: To evaluate changes in choroidal thickness in presbyopes, when reading with regular glasses versus choroidal control glasses, in patients with or without Age-Related Macular Degeneration (AMD). METHODS: This was a pilot study on short-term axial length (AL) in 33 eyes of 24 presbyopic patients aged 60 to 80 years, assigned to two age-matched groups, with or without AMD. About them, changes in choroidal thickness were evaluated with ocular biometry through indirect measurements of axial length at baseline, after 20' of reading with conventional lenses, and after another 20' of reading with peripheral hyperopic defocus glasses. The differences in axial length between the three different times were analyzed. RESULTS: In presbyopes without AMD there was a significant axial length shortening of -13.44 microns in the first conventional reading period, which was reversed by 90% with hyperopic defocus lenses, recovering + 12.11 microns by axial lengthening (choroidal thinning, p = 0.03). In patients with AMD, axial shortening was significantly greater than controls, -23.86 microns with conventional lenses (p < 0.001) and they, also increased their axial length with defocus, although this response was smaller in proportion (+ 15.52 microns). CONCLUSION: Reading with positive lenses produces myopic defocus and choroidal thickening in presbyopes with and without AMD but was significantly greater in the latter. Glasses with Choroidal Control Technology reduced thickening during reading. KEY MESSAGES: What is known • Presbyopia spectacles for near produce myopic defocus and choroidal thickening. What is new • There are differences in choroidal thickening during reading between normal subjects and those with age related macular degeneration. • Spectacles with Defocus Choroidal Control Technology reduce choroidal thickening during reading in presbyopes.

7.
Front Med (Lausanne) ; 11: 1418566, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39247635

RESUMEN

Objective: To investigate the pathogenesis of Primary Angle-Closure Glaucoma (PACG) and its relationship with the anatomical structure of the anterior segment by obtaining biometric parameters using the IOL-Master 700. Methods: A retrospective case-control study was conducted. Clinical data from 39 PACG patients and 40 normal controls treated at the Aier Eye Hospital affiliated with Wuhan University from January to December 2022 were collected. Anterior chamber depth (AC), white-to-white (WTW), lens thickness (LT), central corneal thickness (CCT), axial length (AL), corneal curvature (K1), corneal curvature (K2), and lens position (LP) were measured using the IOL-Master 700 to analyze the characteristics and differences in the anterior segment structure of both groups. Statistical methods included independent sample t-tests and logistic regression analysis. Results: Significant differences were found in the anterior segment biometric parameters between PACG patients and normal controls (p < 0.05). Anterior chamber depth, white-to-white, lens thickness, central corneal thickness, axial length, and K2 were all related to the occurrence of PACG (p < 0.05). The occurrence of PACG was negatively correlated with ACD, CCT, and AL (OR = 0.12-0.64, p < 0.05), and positively correlated with LT. Conclusion: Compared to the normal control group, PACG patients in the Hubei region have a smaller anterior segment space, narrower angles, thicker lens, thinner cornea, shorter axial length, flatter cornea, and more anteriorly positioned lens.

8.
Clin Ophthalmol ; 18: 2225-2238, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39135944

RESUMEN

Purpose: To compare the accuracy of 16 intraocular lens (IOL) power calculation formulas in pediatric cataract eyes. Patients and Methods: The data records of pediatric patients who had been implanted with three IOL models (SA60AT, MA60AC, and enVista-MX60) between 2012 and 2018 were analyzed. The accuracy of 16 IOL power calculation methods was evaluated: Barrett Universal II (BUII), Castrop, EVO 2.0, Haigis, Hill-RBF 3.0, Hoffer Q, Hoffer QST, Holladay 1, Kane, LSF AI, Naeser 2, Pearl-DGS, SRK/T, T2, VRF, and VRF-G. The non-optimized (ULIB/IOLcon) and optimized constants were used for IOL power calculation. The mean prediction error (PE), Performance Index (FPI), and all descriptive statistics were calculated. Results: Ninety-seven eyes of 97 pediatric patients aged 13.2 (IQR 11.2-17.1) were included. No statistically significant difference (HS-test) was observed (p > 0.818) except for the Hoffer Q, and Naeser 2 (P = 0.014). With optimized lens constants, the best FPI indices were obtained by Hoffer Q (0.256) and VRF-G (0.251) formulas, followed by Hill-RBF 3.0 and BUII, with an index of 0.248. The highest FPI indices with non-optimized constants showed SRK/T and T2 formulas (0.246 and 0.245, respectively), followed by VRF-G and Holladay 1, with an index of 0.244. The best median absolute error values (MedAE) were achieved by Hoffer Q (0.50 D), VRF-G (0.53 D), and Hill-RBF 3.0 (0.54 D), all P ≥ 0.074. Conclusion: Our results place the Hoffer Q, VRF-G, Hill-RBF 3.0, and BUII formulas as more accurate predictors of postoperative refraction in pediatric cataract surgery.

9.
Am J Ophthalmol ; 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39128551

RESUMEN

PURPOSE: To investigate the progression patterns and risk factors of axial elongation in young adults with non-pathologic high myopia. DESIGN: Prospective, clinical observational cohort study with 2- to 4-year follow-up. METHODS: A total of 1043 eyes of 563 participants (3515 medical records) aged 18 to 50 years with non-pathologic high myopia (axial length [AL] ≥ 26 mm; myopic maculopathy < diffuse chorioretinal atrophy; without posterior staphyloma) were included from 1546 participants (6318 medical records). Annual axial elongation was calculated via linear mixed-effect models. The associated risk factors of axial elongation were determined by ordinal logistic regression analysis, with generalized estimate equations for eliminating an interocular correlation bias. RESULTS: Based on 5359 times of AL measurements, the annual axial elongation of participants (mean [SD] age 31.39 [9.22] years) was 0.03 mm/year (95% confidence interval [CI], 0.03-0.04, P < 0.001) during a 30.23 (6.06) months' follow-up. Severe (> 0.1 mm/year), moderate (0.05-0.09 mm/year), mild (0-0.049 mm/year), and nil (≤ 0 mm/year) elongation was observed in 122 (11.7%), 211 (20.2%), 417 (40.0%), and 293 (28.1%) eyes. The following risk factors were significantly associated with axial elongation: baseline AL≥ 28 mm (odds ratio [OR], 4.23; 95%CI, 2.95-6.06; P < 0.001); age < 40 years (OR, 1.64; 95%CI, 1.18-2.28; P = 0.003); axial asymmetry (OR, 2.04; 95%CI, 1.26-3.29; P = 0.003), and women (OR, 1.52; 95%CI, 1.13-2.2.05; P = 0.006). Using anti-glaucoma medications was a protective factor (OR, 0.46; 95%CI, 0.27-0.79; P = 0.005), which slowed 75% of axial elongation from 0.04 (0.06) to 0.01 (0.06) mm/y (P < 0.001). CONCLUSIONS: Axial elongation continued in young adults with non-pathologic myopia. Risk factors included longer baseline AL and axial asymmetry, younger age, and woman. Topical use of anti-glaucoma medications may be useful to reduce ongoing axial elongation.

10.
Front Neurosci ; 18: 1457590, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39108309

RESUMEN

[This corrects the article DOI: 10.3389/fnins.2024.1349436.].

11.
Am J Transl Res ; 16(7): 2995-3004, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39114707

RESUMEN

OBJECTIVE: To assess the visual quality, both subjective and objective, of cataract patients with varying axial lengths (AL) after PanOptix trifocal intraocular lens (IOL) implantation and investigated the lens tilt and its correlation with visual outcomes. METHODS: From July 2020 to June 2022, 70 patients (140 eyes) diagnosed with age-related cataracts and undergoing PanOptix implantation at Chongqing Eye and Vision Care Hospital, Aier Eye Hospital Group, were included. Patients were assigned to either the observation group (35 cases, 70 eyes with PanOptix trifocal IOL) or the control group (35 cases, 70 eyes with bifocal IOL). Patients were further subdivided based on AL into AL < 24 mm (observation group: 23 eyes; control group: 26 eyes) and AL ≥ 24 mm (observation group: 47 eyes; control group: 44 eyes). Postoperative follow-up lasted three months. Visual acuity (distant, intermediate, near), objective visual quality (Strehl ratio: SR, total eye modulation transfer function (MTF)), and visual aberrations were measured preoperatively and at 3 months post-operation. RESULTS: Postoperatively, all groups saw significant improvements in uncorrected distance visual acuity (UCDVA), uncorrected intermediate visual acuity (UCIVA), and uncorrected near visual acuity (UCNVA) compared to preoperative values (T0) (all P < 0.05). Notably, UCIVA was significantly better in the observation group than in the control group (P < 0.05). At three months (T1), reductions in total high-order aberration (tHOA), internal high-order aberration (iHOA), coma, and trefoil aberrations were observed in both groups compared to baseline, with more significant decreases in the observation group (all P < 0.05). Both SR and MTF cutoff showed marked improvement from T0 to T1, with the observation group experiencing greater enhancements (both P < 0.05). The defocus curve of the observation group showed a gentle slope between +0.5 D and -3.0 D, maintaining superior visual acuity compared to the control group (P < 0.05). Subjective visual quality scores at T1 were significantly higher than at T0 for both groups (P < 0.05), with patients in the observation group scoring higher than those in the control group across all AL categories (P < 0.05). Spearman correlation analysis indicated that the tilt after PanOptix trifocal IOL implantation was associated with tHOA (r = 0.273, P = 0.022), iHOA (r = 0.433, P < 0.001), Trefoil (r = 0.360, P = 0.002) and coma (r = 0.688, P < 0.001). CONCLUSION: PanOptix trifocal IOL implantation in cataract patients across different AL significantly enhances visual quality compared to bifocal IOLs, suggesting a strong case for its clinical adoption.

12.
Am J Ophthalmol ; 2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-39197509

RESUMEN

PURPOSE: Spectacle lenses with highly aspherical lenslets (HAL) have been shown to effectively retard myopia progression in myopic children. This study aimed to investigate the impact of spectacle lenses with HAL on refractive and axial length (AL) changes in Chinese children with low amount of hyperopia. DESIGN: Randomized controlled trial METHODS: : A total of 108 Chinese children aged 6.0 to 9.9 years and spherical equivalent refractive error (SERE) from 0.00 to +2.00 D were randomly allocated into two groups: the HAL group and the single vision spectacle lens (SVL) group. Cycloplegic refraction, AL, and uncorrected visual acuity (UCVA) was measured at baseline, three months, six months, and 12 months after lens dispensing. The duration of spectacle lens wear was monitored using a wearable device attached to the spectacle frame and by questionnaire logs provided by participants at each follow up visit. RESULTS: The one-year SERE change was -0.19 [-0.32, 0.03] D and -0.23 [-0.36, 0.05] D in the SVL and HAL groups (P=0.883). The one-year AL elongation was 0.24 [0.18, 0.34] mm and 0.19 [0.12, 0.27] mm in the SVL and HAL groups (P=0.057). In the HAL group, changes in AL and SERE were significantly correlated to lens wearing time (P<0.001 and P=0.024, respectively). Participants in the HAL group who wore their lenses for more than 30 hours per week had significantly slower AL elongation (0.11 [0.05, 0.17] mm) compared to their SVL counterparts (0.27 [0.21, 0.33] mm) (P<0.001). CONCLUSION: Spectacle lenses with HAL significantly reduced AL elongation in low hyperopic children who wore lenses for over 30 hours per week. A dose-response relationship was evident with longer lens wearing time associated with less AL change.

13.
J Clin Med ; 13(16)2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39200782

RESUMEN

Objectives: This study aims to verify the accuracy of a new calculation formula, Barrett true axial length formula (T-AL), and the optimized lens factor (LF) for predicting postoperative refraction after cataract surgery. Methods: We included 156 Japanese patients who underwent cataract surgery using Clareon monofocal intraocular lenses at our clinic between January 2022 and June 2023. Postoperative spherical equivalent was calculated using subjective refraction values obtained 1 month post-surgery. The LFs were optimized so that the mean prediction error (PE) of each calculation formula was zero (zero optimization). We calculated the mean absolute PE (MAE) to assess accuracy and used a Friedman test for statistical comparisons. The accuracy of T-AL and the optimized LFs was compared with that of the conventional Barrett Universal II formula for ARGOS (AR-B) and OA-2000 (OA-B) with equivalent refractive index. Results: For T-AL, AR-B, and OA-B, the MAEs ± standard deviations were 0.225 ± 0.179, 0.219 ± 0.168, and 0.242 ± 0.206 D, respectively. The Friedman test showed no statistically significant differences among the three groups. The device-optimized LFs were 2.248-2.289 (T-AL), 2.236-2.246 (AR-B), and 2.07-2.08 (OA-B); the corresponding zero-optimized LFs were 2.262-2.287 (T-AL), 2.287-2.303 (AR-B), and 2.160-2.170 (OA-B). Conclusion: There were no significant differences in prediction accuracy among the formulas. However, the accuracy of LF optimization varied by device, with T-AL being closest to the value under zero optimization. This suggests that T-AL is clinically useful for predicting an accurate postoperative refraction without zero optimization.

14.
BMC Ophthalmol ; 24(1): 382, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39198780

RESUMEN

PURPOSE: To investigate the correlation between whole eye movement (WEM) parameters measured using Corvis ST and axial length (AL) to explore whether AL affects WEMs. METHODS: This single-center, cross-sectional study included data from healthy subjects and patients preparing for refractive surgery at the Qingdao Eye Hospital of Shandong First Medical University. Data were collected from July 2021 to April 2022. We first determined the correlations of WEMs at the time of corneal first applanation (A1_WEM), highest concavity (HC_WEM), and second applanation (A2_WEM), as well as the maximum value of WEM (WEM_Max) with AL. Subsequently, we established a series of regression models to analyze the relationships between different WEM values and AL. RESULTS: AL was negatively correlated with HC_WEM, A2_WEM, and WEM_Max (r = - 0.28, - 0.23, and - 0.22, respectively; P < 0.001). The correlation between AL and A1_WEM was not significant (P = 0.77). According to the adjusted regression models, AL was negatively associated with HC_WEM (Model 2: ß = -7.39, P < 0.001) and WEM_Max (Model 4: ß = -3.52, P = 0.02), while the associations of AL with A1_WEM (Model 1: P = 0.61) and A2_WEM (Model 3: P = 0.23) were not significant. CONCLUSIONS: AL is an independent negative influencing factor for HC_WEM. WEM is a potentially useful parameter that reflects the biomechanical properties of the eye behind the cornea in myopia.


Asunto(s)
Longitud Axial del Ojo , Córnea , Movimientos Oculares , Miopía , Humanos , Miopía/fisiopatología , Miopía/terapia , Estudios Transversales , Córnea/fisiopatología , Masculino , Femenino , Adulto , Adulto Joven , Movimientos Oculares/fisiología , Tonometría Ocular , Persona de Mediana Edad , Refracción Ocular/fisiología
15.
Diagnostics (Basel) ; 14(16)2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39202205

RESUMEN

We aimed to survey the potential correlation between biometric parameters and postoperative outcomes after implanting extended depth-of-focus (EDOF) intraocular lenses (IOLs) and trifocal IOLs. A retrospective cohort study was conducted, and patients receiving EDOF or trifocal IOL implantations were included. In total, 36 and 26 eyes were enrolled in the EDOF and trifocal groups, respectively. The primary outcomes of this study were the postoperative uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), and spherical equivalent (SE). The generalized linear model was applied to evaluate the adjusted odds ratio (aOR) and 95% confidence intervals (CIs) of primary outcomes in patients with different biometric characters. The final UDVA of the EDOF group was significantly better than that of the trifocal group (p = 0.020), and the UNVA and SE did not show significant differences between the two groups throughout the postoperative period (all p > 0.05). In a multivariable analysis, the UDVA was significantly better in the EDOF group than in the trifocal group (p = 0.038). For the subgroup analysis, the high axial length (AXL) value correlated to a lower postoperative UDVA in the EDOF group (both p < 0.05). Additionally, a large white-to-white (WTW) diameter was related to worse postoperative UNVA in the trifocal group (p = 0.042), and a high AXL was associated with higher SE in both the EDOF and trifocal groups (both p < 0.05). In conclusion, a high AXL correlates to worse postoperative outcomes in both the EDOF and trifocal IOLs, and trifocal IOL outcomes could be affected by large WTW diameters.

16.
Vision (Basel) ; 8(3)2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39189184

RESUMEN

This study evaluates the inter-device measurement properties of partial coherence interferometry (PCI) and spectral domain optical coherence tomography (SD-OCT) in measuring axial length, particularly for myopia management. We recruited 82 eyes from 41 adult participants with a mean age of 31.0 ± 17.6 years and a mean spherical equivalent of -2.20 ± 2.28 D. Axial length was measured using SD-OCT and PCI for both the right and left eyes. Agreement between the two measurements was assessed using Bland-Altman analysis, and graphs and values were compared with linear mixed models. The results show a near-to-zero and non-significant bias between measurements. The 95% limits of agreement showed a value of 0.06 mm. Both devices can accurately measure the axial length. OCT biometry performed with SD-OCT can be successfully interchanged with partial coherence interferometry, but they should be cautiously interchanged when performing longitudinal comparisons.

17.
Ophthalmic Res ; 67(1): 488-498, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39111293

RESUMEN

INTRODUCTION: The aim of the study was to investigate the association of parameters related to accommodation and convergence and axial elongation in basic intermittent exotropia (IXT) patients and the potential clinical predictors of axial length (AL) growth. METHODS: A total of 140 basic IXT patients were recruited in this study. The medians of AL growth in different age brackets were chosen to divide the subjects into group A (slower axial elongation group, n = 69) and group B (faster axial elongation group, n = 71). Parameters of dominant and nondominant eyes were compared and analyzed during the 12-month follow-up period. The parameters, including baseline refraction, angle of deviation, Newcastle control score (NCS), accommodative amplitude (AMP), accommodative facility (AMF), accommodative response, positive or negative relative accommodation (PRA/NRA), and near point of convergence (NPC), were analyzed via univariate and multivariate regression. RESULTS: Subjects in the faster axial elongation group tended to have more myopic spherical equivalents (t = 3.956, p < 0.001), greater AMPs of dominant eyes (t = -2.238, p = 0.027), and fewer near points of convergence (t = 2.347, p = 0.020) than in the slower axial elongation group. For dominant eyes, logistic and linear regression analysis revealed that more negative spherical equivalents (OR = 0.603, p < 0.001; ß = -0.045, p < 0.001), greater AMPs (OR = 1.201, p = 0.027; ß = 0.023, p = 0.010), and less near points of convergence (OR = 0.883, p = 0.021; ß = -0.012, p = 0.019) were correlated with the faster axial elongation. For nondominant eyes, a more myopic spherical equivalent (OR = 0.682; p = 0.001; ß = -0.029, p = 0.005) was the only parameter correlated with faster axial elongation through regression analysis. CONCLUSION: In children with basic IXT, faster axial elongation in the dominant eyes was associated with more myopic spherical equivalents, greater AMPs, and lower NPCs. These accommodative parameters can serve as potential clinical indicators for monitoring myopia progression in addition to AL.


Asunto(s)
Acomodación Ocular , Longitud Axial del Ojo , Convergencia Ocular , Exotropía , Refracción Ocular , Humanos , Acomodación Ocular/fisiología , Exotropía/fisiopatología , Masculino , Femenino , Longitud Axial del Ojo/fisiopatología , Niño , Convergencia Ocular/fisiología , Preescolar , Refracción Ocular/fisiología , Estudios de Seguimiento , Agudeza Visual/fisiología , Visión Binocular/fisiología , Estudios Retrospectivos
18.
BMC Ophthalmol ; 24(1): 321, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39090603

RESUMEN

BACKGROUND: Assessing refractive errors under cycloplegia is recommended for paediatric patients; however, this may not always be feasible. In these situations, refraction has to rely on measurements made under active accommodation which may increase measurements variability and error. Therefore, evaluating the accuracy and precision of non-cycloplegic refraction and biometric measurements is clinically relevant. The Myopia Master, a novel instrument combining autorefraction and biometry, is designed for monitoring refractive error and ocular biometry in myopia management. This study assessed its repeatability and agreement for autorefraction and biometric measurements pre- and post-cycloplegia. METHODS: A prospective cross-sectional study evaluated a cohort of 96 paediatric patients that underwent ophthalmologic examination. An optometrist performed two repeated measurements of autorefraction and biometry pre- and post-cycloplegia. Test-retest repeatability (TRT) was assessed as differences between consecutive measurements and agreement as differences between post- and pre-cycloplegia measurements, for spherical equivalent (SE), refractive and keratometric J0/J45 astigmatic components, mean keratometry (Km) and axial length (AL). RESULTS: Cycloplegia significantly improved the SE repeatability (TRT, pre-cyclo: 0.65 D, post-cyclo: 0.31 D). SE measurements were more repeatable in myopes and emmetropes compared to hyperopes. Keratometry (Km) repeatability did not change with cycloplegia (TRT, pre-cyclo: 0.25 D, post-cyclo:0.27 D) and AL repeatability improved marginally (TRT, pre-cyclo: 0.14 mm, post-cyclo: 0.09 mm). Regarding pre- and post-cycloplegia agreement, SE became more positive by + 0.79 D, varying with refractive error. Myopic eyes showed a mean difference of + 0.31 D, while hyperopes differed by + 1.57 D. Mean keratometry, refractive and keratometric J0/J45 and AL showed no clinically significant differences. CONCLUSIONS: Refractive error measurements, using the Myopia Master were 2.5x less precise pre-cycloplegia than post-cycloplegia. Accuracy of pre-cycloplegic refractive error measurements was often larger than the clinically significant threshold (0.25 D) and was refractive error dependent. The higher precision compared to autorefraction measurements, pre- and post-cycloplegia agreement and refractive error independence of AL measurements emphasize the superiority of AL in refractive error monitoring.


Asunto(s)
Longitud Axial del Ojo , Biometría , Midriáticos , Miopía , Refracción Ocular , Humanos , Estudios Prospectivos , Estudios Transversales , Femenino , Masculino , Refracción Ocular/fisiología , Midriáticos/administración & dosificación , Niño , Miopía/fisiopatología , Biometría/métodos , Adolescente , Reproducibilidad de los Resultados , Pupila/efectos de los fármacos , Pupila/fisiología , Córnea/patología , Córnea/fisiopatología
19.
BMC Ophthalmol ; 24(1): 329, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39112923

RESUMEN

BACKGROUND: Considering that changes in the choroidal thickness are closely related to ocular growth, we studied the choroidal thickness (CT) and the blood flow features in children with unilateral myopic anisometropia (UMA) as well as investigating the relationship between choroidal changes and myopia. METHODS: Subjective refractive, axial length (AL), and biometric parameters were measured in 98 UMA children (age: 8-15 years). CT and choroidal blood-flow features, including the choroidal vessel volume (CVV), choroidal vascularity index (CVI), and choriocapillaris perfusion area (CCPA), were measured through swept-source optical coherence tomography angiography. The macular region was categorized into four concentric circles of diameters 0-1 mm (central fovea), 1-3 mm (parafovea), 3-6 mm (perifovea), and 6-9 mm (extended), and further categorized into superior (S), inferior (I), temporal (T), and nasal (N) quadrants. RESULTS: The aforementioned four regions of myopic eyes displayed significantly lower CT, CVV, and CVI than those of non-myopic eyes. CCPA changes differed across different regions of both the eyes (parts of N and T quadrants). There was an inverse association between CT and the interocular AL difference (central and other regions S, T quadrant). No correlation was noted between CVV and CVI with interocular AL difference. CT and CVV were positively correlated in the 0-6-mm macular region of myopic eyes (Spearman correlation coefficient = 0.763, P < 0.001). CONCLUSIONS: In UMA children, CCT and blood flow may be related to myopia progression. A robust correlation between CT and CVV in the 0-6-mm macular region and reduced CT and diminished blood flow indicated an association with myopia.


Asunto(s)
Anisometropía , Longitud Axial del Ojo , Coroides , Miopía , Flujo Sanguíneo Regional , Tomografía de Coherencia Óptica , Humanos , Coroides/irrigación sanguínea , Coroides/patología , Coroides/diagnóstico por imagen , Niño , Adolescente , Masculino , Femenino , Anisometropía/fisiopatología , Miopía/fisiopatología , Tomografía de Coherencia Óptica/métodos , Longitud Axial del Ojo/patología , Flujo Sanguíneo Regional/fisiología , Refracción Ocular/fisiología , Angiografía con Fluoresceína/métodos
20.
Saudi J Ophthalmol ; 38(2): 152-156, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38988782

RESUMEN

PURPOSE: The purpose of the study is to establish normative values of eye parameters such as lens thickness (LT), lens diameter (LD), and axial length (AXL) among wide age range of Saudis using Pentacam AXL and compare these values between gender, in addition to that, to find the correlation between the age and those parameters. METHODS: In this prospective cross-sectional study, we measured LT, LD, and AXL in 125 healthy Saudi controls aged between 8 and 60 years using OCULUS Pentacam AXL. The screening tests were performed for each subject to exclude any ocular abnormalities using slit lamp (Haag-Streit BQ 900), refractive error measured using auto refractometer (Topcon KR-1 Autorefractor/Keratometer), and subject who has spherical equivalent more than ± 4.00D and astigmatism more than 1.00DC was excluded from the study. The mean of three readings of LT, LD, and AXL was taken. All examination was applied on one eye (right eye). RESULTS: The overall mean and standard deviation of LT, LD, and AXL was 2.2 mm ± 0.5, 2.7 mm ± 0.6, and 23.8 mm ± 1.0, respectively. There was no statistically significant difference between males and females in these parameters in all age groups, except in Group 2 (age: 19-30 years), there was a statistically significant difference between males and females in AXL, mean difference (M = 0.48), and P = 0.015. The mean of LT and LD was negatively associated with age. However, there was no significant correlation between AXL and age. CONCLUSION: Normative values of LT, LD, and AXL have been established in wide age group of healthy Saudis; the findings of the present study can highlight not only the normal range of the different ocular parameters, namely LT, LD, and AXL, but also their variation with age and gender.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA