J Pers Med ; 14(2)2024 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-38392611

RESUMEN

We report here a 46-year-old male patient with a 14 cm segmental bone defect of the radial shaft after third degree open infected fracture caused by a shrapnel injury. The patient underwent fixed-angle plate osteosynthesis and bone reconstruction of the radial shaft by a vascularized 3D-printed graft cage, including plastic coverage with a latissimus dorsi flap and an additional central vascular pedicle. Bony reconstruction of segmental defects still represents a major challenge in musculo-skeletal surgery. Thereby, 3D-printed scaffolds or graft cages display a new treatment option for bone restoration. As missing vascularization sets the limits for the treatment of large-volume bone defects by 3D-printed scaffolds, in the present case, we firstly describe the reconstruction of an extensive radial shaft bone defect by using a graft cage with additional vascularization.