RESUMEN
In this work, the metallic silver and non-metallic nitrogen co-doped reduced graphene oxide (Ag-N-RGO) was first synthesized by a simple and cost-effective strategy, and then a molecularly imprinted polymer (MIP) was formed in situ at the surface of the prepared composite via electropolymerization of o-phenylenediamine in the presence of salbutamol as the template molecule. The electrochemical characterizations demonstrate that the bifunctional graphene-based composite shows improved catalytic performance than that of pristine graphene doped with one-component or none. The MIP sensor based on Ag-N-RGO owns high porous surface structure, resulting in the increased current response and enhanced recognition capacity than that of non-imprinted sensor. The outstanding performance of the developed sensor derives from the combined advantages of Ag-N-RGO with effective catalytic property and MIP with excellent selectivity. Under the optimal conditions, the electrochemical response of the developed sensor is linearly proportional to the concentration of salbutamol in the range of 0.03-20.00µmolL-1 with a low detection limit of 7 nmol L-1. The designed sensor has exhibited the multiple advantages such as low cost, simple manufacture, convenient use, excellent selectivity and good reproducibility. Finally, the proposed method has been extended for the determinations of salbutamol in human urine and pork samples, and the satisfactory recoveries between 98.9-105.3% are achieved.
Asunto(s)
Agonistas de Receptores Adrenérgicos beta 2/análisis , Agonistas de Receptores Adrenérgicos beta 2/orina , Albuterol/análisis , Albuterol/orina , Técnicas Electroquímicas/métodos , Grafito/química , Carne Roja/análisis , Animales , Técnicas Biosensibles/métodos , Catálisis , Humanos , Límite de Detección , Impresión Molecular/métodos , Oxidación-Reducción , Óxidos/química , Polímeros/química , Plata/química , PorcinosRESUMEN
Formoterol is a long acting ß(2)-agonist and has proven to be a very effective bronchodilating agent. Hence it is frequently applied therapeutically for the treatment of asthma. Because ß(2)-agonists might be misused in sports for the stimulatory effects and for growth-promoting action their use is restricted. Since January 2012, formoterol is prohibited in urinary concentrations higher than 30 ng/mL. The objective of this study was to develop and validate a simple and robust ultra high performance liquid chromatographic-tandem mass spectrometric (UHPLC-MS/MS) method for the direct quantification of formoterol in urine. Sample preparation was limited to an enzymatic hydrolysis step after which 2 µL was injected in the chromatographic system. Chromatography was performed on a C(8)-column using gradient conditions. The mobile phase consisted of water/methanol (H(2)O/MeOH) both containing 0.1% acetic acid (HOAc) and 1mM ammonium acetate (NH(4)OAc). Calibration curve were constructed between 15 and 60 ng/mL. Validation data showed bias of 1.3% and imprecision of 5.4% at the threshold. Ion suppression/enhancement never exceeded 7%. Calculating measurement uncertainty showed proof of applicability of the method. Stability of formoterol was also investigated at 56 °C (accelerated stability test) at pH 1.0/5.2/7.0 and 9.5. At the physiological pH values of 5.2 and 7.0, formoterol showed good stability. At pH 1.0 and 9.5 significant degradation was observed.