Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.788
Filtrar
1.
J Refract Surg ; 40(8): e520-e526, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39120022

RESUMEN

PURPOSE: To compare the outcomes of anterior chamber intraocular lens (AC-IOL) implantation versus the four-flanged scleral fixation technique in eyes with loss of capsular support during routine cataract surgery. METHODS: This was a retrospective cohort study of all patients in whom an IOL was implanted either during or after short-term aphakia due to loss of capsular and sulcus support in a routine cataract surgery with at least 6 months of follow-up time between 2015 and 2023 in a tertiary medical center in Israel. Two different IOL implantation techniques were compared: the implantation of an angle-supported ACIOL and four-flanged scleral fixation. Main outcome measures included postoperative complications such as pseudophakic bullous keratopathy, loss of intraocular pressure control and glaucoma, IOL subluxation, and retinal detachment. RESULTS: Sixty-five eyes of 65 patients were included in the study, 33 eyes in the AC-IOL group and 32 eyes in the flange group. Follow-up time was 29.92 ± 20.02 months in the AC-IOL group and 20.17 ± 15.56 months in the flange group (P = .087). Pseudophakic bullous keratopathy was observed in 10 (30.3%) patients in the AC-IOL group and in 1 (3.1%) patient in the flange group (P = .04). This association remained significant using survival analysis (P = .006). In 4 (12.1%) patients in the AC-IOL group, a glaucoma filtering procedure was performed to control the intraocular pressure compared with none in the flange group (P = .042). CONCLUSIONS: In the setting of loss of capsular support during routine cataract surgery, four-flanged scleral fixation showed an overall lower rate of complications and significantly reduced rate of subsequent surgical interventions. [J Refract Surg. 2024;40(8):e520-e526.].


Asunto(s)
Cámara Anterior , Implantación de Lentes Intraoculares , Esclerótica , Agudeza Visual , Humanos , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Esclerótica/cirugía , Femenino , Masculino , Anciano , Agudeza Visual/fisiología , Persona de Mediana Edad , Cámara Anterior/cirugía , Complicaciones Posoperatorias , Técnicas de Sutura , Estudios de Seguimiento , Presión Intraocular/fisiología , Lentes Intraoculares , Extracción de Catarata/métodos , Facoemulsificación/métodos , Anciano de 80 o más Años , Cápsula del Cristalino/cirugía , Seudofaquia/fisiopatología
2.
Indian J Ophthalmol ; 72(7): 1075, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38905471

RESUMEN

BACKGROUND: Traboulsi syndrome is a sporadic autosomal recessive disorder. Very few cases reported and no surgical treatment has been described. PURPOSE: The purpose of the study was to describe the surgical treatment of a case of Traboulsi syndrome with intercalary staphyloma. SYNOPSIS: Traboulsi syndrome[1-3] is a type of spontaneous filtering bleb. The case was of a 31-year-old lady with a flat anterior chamber and large intercalary staphyloma, with a subluxated clear lens. Liberal peritomy was done. The staphyloma was cut and the displaced lens was delivered through it. It was closed with 7-0 vicryl continuous suture. A cross-linked cornea was used after removing the Descemet membrane. It was modified to match the crescentic shape of the limbus by using 11 and 6 mm trephine. Two wedge-shaped defects were created and tissue was excised between them, which were then sutured to increase the arc radius. A peripheral flange at the corneal edge was created. A pocket was created in the host cornea to accommodate the donor corneal flange. The donor cornea was tucked in and the graft was sutured. The sclera was used to suture another side prophylactically, making a 360-degree encirclage. The patient got ambulatory vision postsurgery. The use of the cornea as biological encirclage has not been described previously. HIGHLIGHTS: Using a cross-linked cornea. Creating wedge-shaped defects in crescentic corneal graft to increase arc radius. Use of cornea as encirclage.Link of video:https://youtu.be/T3b5rkvFmlc.


Asunto(s)
Agudeza Visual , Humanos , Adulto , Femenino , Cámara Anterior/cirugía , Síndrome , Subluxación del Cristalino/cirugía , Subluxación del Cristalino/diagnóstico , Procedimientos Quirúrgicos Oftalmológicos/métodos , Técnicas de Sutura , Presión Intraocular/fisiología
3.
J Mater Sci Mater Med ; 35(1): 37, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38916635

RESUMEN

The current clinical application of glaucoma drainage devices is made of non-degradable materials. These non-degradable drainage devices often trigger inflammatory responses and scar proliferation, possibly leading to surgical failure. We developed a biodegradable material hydroxyapatite-coated magnesium (HA-Mg) as a glaucoma drainage device. Twelve New Zealand white rabbits were randomly assigned to three groups: HA-Mg drainage plate group (6 right eyes), trabeculectomy group (6 right eyes), and control group (12 left eyes). Results showed that all HA-Mg drainage plates were completely degraded ~4 months postoperatively. At the 5th month postoperatively, there was no statistical difference in the corneal endothelium density between the HA-Mg drainage plate group and the control group (p = 0.857). The intraocular pressure (IOP) level in the HA-Mg drainage plate implantation group was lower than in the other two groups. The trypan blue dye still drained from the anterior chamber to the subconjunctiva 5 months after HA-Mg drainage plate implantation. HE staining revealed the scleral linear aqueous humor drainage channel and anterior synechia were observed after drainage plate completely degraded, with no obvious infiltration with the inflammatory cells. This study showed the safety and efficacy of HA-Mg glaucoma drainage plate in controlling IOP after implantation into the anterior chamber of rabbit eyes.


Asunto(s)
Cámara Anterior , Implantes de Drenaje de Glaucoma , Glaucoma , Presión Intraocular , Magnesio , Animales , Conejos , Cámara Anterior/cirugía , Glaucoma/cirugía , Magnesio/química , Durapatita/química , Trabeculectomía/métodos
4.
Eur J Ophthalmol ; 34(4): NP25-NP28, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38613315

RESUMEN

BACKGROUND: Glaucoma is a progressive optic neuropathy and it is the main cause of irreversible blindness worldwide. Intraocular pressure (IOP) is the only modifiable one and trabeculectomy is commonly considered the surgical "gold standard" to decrease IOP. In particular cases, other kind of surgeries, as the Ahmed Glaucoma Valve (AGV) implant, are a reliable alternative. Usually, the silicone tube of AGV surgery is inserted into the anterior chamber. Sometimes it is necessary to place the AGV silicone tube in the ciliary sulcus, especially in cases of endothelial decompensation. This surgical procedure is not always easy to perform. CASE PRESENTATION: This article describes and presents a technique for inserting the AGV tube into the posterior chamber using a guide-wire, in a total of 12 cases are reported. This procedure has been mostly applied in a group of pseudophakic patients who need AGV placement to control elevated IOP. In exceptional situations, this procedure was applied in pseudophakic patients previously with AGV tube implanted in the anterior chamber and with loss of endothelial cells or in phakic patients with previously implanted AGV anterior chamber tube, simultaneously to cataract surgery. CONCLUSION: The purpose of these cases presentations attended at our service is to demonstrate the passage of the AGV silicone tube was performed with the aid of a guide wire.


Asunto(s)
Cuerpo Ciliar , Implantes de Drenaje de Glaucoma , Presión Intraocular , Humanos , Presión Intraocular/fisiología , Cuerpo Ciliar/cirugía , Masculino , Femenino , Glaucoma/cirugía , Glaucoma/fisiopatología , Implantación de Prótesis/métodos , Anciano , Persona de Mediana Edad , Intubación/instrumentación , Agudeza Visual/fisiología , Cámara Anterior/cirugía
5.
Trials ; 25(1): 287, 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38679725

RESUMEN

BACKGROUND: Neovascular glaucoma (NVG) is an irreversible blinding eye disease worldwide and is classified as one of the refractory glaucoma conditions, severely impacting visual function and vision. Unfortunately, effective surgical interventions to improve the prognosis of NVG patients are currently lacking. The study aims to evaluate the efficacy and safety of anterior chamber proliferative membrane interception (AC-PMI)-enhanced trabeculectomy compared to the traditional trabeculectomy. METHODS: AC-PMI enhanced trabeculectomy versus trabeculectomy for the treatment of NVG is a single-center, prospective, double-arms, and randomized controlled trial of superior efficacy, which will involve 100 NVG inpatients. Patients will be randomly assigned into two groups using the random number table method. One group will undergo trabeculectomy using anti-vascular endothelial growth factor (Anti-VEGF) preoperatively and mitomycin C intraoperatively, while the other group will undergo AC-PMI enhanced trabeculectomy with the same medications (Anti-VEGF and mitomycin C). The patients will be followed up at the baseline and 1 day, 1 week, 1 month, 3 months, 6 months, 12 months, 18 months, and 24 months postoperatively. Meanwhile, we will collect the demographics, characteristics, and examination results and monitor any occurrences of adverse events at each follow-up time. DISCUSSION: This is an efficacy study of a novel surgical approach for treating neovascular glaucoma. Building upon conventional filtering surgeries, this approach introduces an additional step involving the interception of the proliferative membrane to effectively halt the growth of fibrovascular tissue. This study aims to explore a promising new surgical approach for managing NVG and contribute to the advancement of glaucoma treatment strategies. TRIAL REGISTRATION: ChiCTR ChiCTR2200055138. Registered on 01 January 2022. https://www.chictr.org.cn/showproj.html?proj=145255.


Asunto(s)
Glaucoma Neovascular , Ensayos Clínicos Controlados Aleatorios como Asunto , Trabeculectomía , Factor A de Crecimiento Endotelial Vascular , Humanos , Trabeculectomía/métodos , Trabeculectomía/efectos adversos , Glaucoma Neovascular/cirugía , Glaucoma Neovascular/fisiopatología , Estudios Prospectivos , Resultado del Tratamiento , Persona de Mediana Edad , Factor A de Crecimiento Endotelial Vascular/antagonistas & inhibidores , Anciano , Femenino , Masculino , Adulto , Cámara Anterior/cirugía , Presión Intraocular , Mitomicina/uso terapéutico , Mitomicina/administración & dosificación , Inhibidores de la Angiogénesis/uso terapéutico , Inhibidores de la Angiogénesis/administración & dosificación , Adulto Joven
7.
Indian J Ophthalmol ; 72(Suppl 3): S533-S535, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38317304

RESUMEN

Some anterior chambers do not readily shallow because of insufficient posterior pressure and/or very deep anterior chamber anatomy, which can make unscrolling descemet membrane endothelial keratoplasty (DMEK) tissue more challenging with an unmodified tap technique. We present a hands-free method for augmenting posterior pressure by temporarily tucking cellulose sponges under the blades of the eyelid speculum. The sponges transfer some of the eyelid speculum's weight onto the bulbar surface posterior to the iris, thereby indenting the sclera and causing the iris diaphragm to bulge further forward. This hands-free technique can transform a potentially challenging DMEK case into a more straightforward one by facilitating both a shallow anterior chamber and a bimanual unscrolling technique. However, it only works in bicameral eyes with a vitreous body (e.g., an eye with penetrating keratoplasty, vitreous syneresis, and axial myopia) and will not work in unicameral eyes after vitrectomy (e.g., an eye with an Anterior Chamber Intraocular Lens (ACIOL)).


Asunto(s)
Cámara Anterior , Queratoplastia Endotelial de la Lámina Limitante Posterior , Humanos , Queratoplastia Endotelial de la Lámina Limitante Posterior/métodos , Cámara Anterior/cirugía , Celulosa , Presión Intraocular/fisiología , Agudeza Visual
8.
Sci Rep ; 14(1): 4452, 2024 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-38396005

RESUMEN

To carry out the preclinical and histological evaluation of a novel nanotechnology-based microshunt for drainage glaucoma surgery. Twelve New Zealand White rabbits were implanted with a novel microshunt and followed up for 6 weeks. The new material composite consists of the silicone polydimethylsiloxane (PDMS) and tetrapodal Zinc Oxide (ZnO-T) nano-/microparticles. The microshunts were inserted ab externo to connect the subconjunctival space with the anterior chamber. Animals were euthanized after 2 and 6 weeks for histological evaluation. Ocular health and implant position were assessed at postoperative days 1, 3, 7 and twice a week thereafter by slit lamp biomicroscopy. Intraocular pressure (IOP) was measured using rebound tonometry. A good tolerability was observed in both short- and medium-term follow-up. Intraocular pressure was reduced following surgery but increased to preoperative levels after 2 weeks. No clinical or histological signs of inflammatory or toxic reactions were seen; the fibrotic encapsulation was barely noticeable after two weeks and very mild after six weeks. The new material composite PDMS/ZnO-T is well tolerated and the associated foreign body fibrotic reaction quite mild. The new microshunt reduces the IOP for 2 weeks. Further research will elucidate a tube-like shape to improve and prolong outflow performance and longer follow-up to exclude medium-term adverse effects.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma , Óxido de Zinc , Animales , Conejos , Implantes de Drenaje de Glaucoma/efectos adversos , Glaucoma/cirugía , Glaucoma/etiología , Presión Intraocular , Tonometría Ocular , Cámara Anterior/cirugía , Nanotecnología
9.
Eur J Ophthalmol ; 34(3): NP22-NP28, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38387873

RESUMEN

PURPOSE: To report a challenging Descemet Membrane Endothelial Keratoplasty (DMEK) case, complicated by intraoperative aqueous misdirection and spontaneous anterior chamber fibrin reaction. METHODS: A 70-year-old female affected by corneal edema due to Fuchs endothelial dystrophy underwent a triple procedure (cataract extraction - IOL implantation - DMEK surgery) in her left eye. This report illustrates the management of the intraoperative complications of aqueous misdirection syndrome and anterior chamber fibrin reaction. RESULTS: Despite the optimal management of the posterior pressure and the thorough removal of the fibrinous reaction during the case, the DMEK graft was not completely unfolded and centred at the end of the surgical procedure. Nonetheless, the patient showed good long-term anatomical and functional recovery: at the last follow-up (2 years after surgery), central corneal thickness was 526 µm with a best corrected visual acuity of 20/25 and an endothelial cell density of 1112 cell/mm2. CONCLUSION: Early recognition and prompt management of intraoperative aqueous misdirection syndrome and anterior chamber fibrin reaction during DMEK surgery is essential to ensure good functional and anatomical outcomes.


Asunto(s)
Edema Corneal , Queratoplastia Endotelial de la Lámina Limitante Posterior , Distrofia Endotelial de Fuchs , Complicaciones Intraoperatorias , Agudeza Visual , Humanos , Femenino , Anciano , Distrofia Endotelial de Fuchs/cirugía , Distrofia Endotelial de Fuchs/fisiopatología , Agudeza Visual/fisiología , Edema Corneal/diagnóstico , Edema Corneal/etiología , Edema Corneal/cirugía , Implantación de Lentes Intraoculares , Cámara Anterior/patología , Cámara Anterior/cirugía , Tomografía de Coherencia Óptica , Humor Acuoso/metabolismo
10.
Sci Adv ; 10(6): eadk7805, 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38324695

RESUMEN

Glaucoma causes irreversible vision loss due to optic nerve damage and retinal cell degeneration. Since high intraocular pressure (IOP) is a major risk factor for glaucoma development, accurate IOP measurement is crucial, especially intravitreal IOP affecting the optical nerve and cells. However, conventional methods have limits in selectively and directly detecting local retina pressure. Here, we present continuous measurements of local IOP values in the anterior chamber and vitreous chamber of living animals using minimally invasive probes with pressure-sensitive transistors. After inducing glaucoma in animal models, we compared the local IOP distribution between normal and glaucomatous eyes. We also compared IOP values detected in the cornea using tonometry measurements. Our findings revealed that glaucoma induced higher IOP in the vitreous chamber than in the anterior chamber, indicating that measuring IOP in the vitreous chamber is key to the glaucoma model. This progress offers future directions for diagnosis and treatment of glaucoma.


Asunto(s)
Glaucoma , Presión Intraocular , Animales , Glaucoma/diagnóstico , Glaucoma/cirugía , Tonometría Ocular , Cámara Anterior/cirugía , Retina
11.
Arch Soc Esp Oftalmol (Engl Ed) ; 99(4): 152-157, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38309658

RESUMEN

INTRODUCTION: Lamellar keratoplasties have had a great impact in the management of corneal edema due to endothelial dysfunction. Minimally invasive transplant techniques such as Descemet Membrane Endothelial Keratoplasty (DMEK) have helped to reduce the morbidity involved in performing penetrating keratoplasty in this type of patient. Even so, these are complex techniques that are not free of complications and require a long line of surgical learning and an even more demanding experience in postoperative management. CLINICAL CASE: An 89-year-old woman suffering from Fuchs endothelial dystrophy and undergoing combined cataract and DMEK surgery presented stromal edema predominantly inferior and sectoral detachment of the graft 24 h after the intervention. After re-bubbling in consultations and 4 days later, the graft was observed rolled and free in the anterior chamber. She underwent re-DMEK with preservation of the original graft after 24 h, with de-epithelialization to optimize visualization. The graft was stained with trypan blue and the posterior stroma was protected with air. The graft was reimplanted under intraocular maneuvers and with an air bubble. 24 h after surgery, the adhered graft was observed, with a great decrease in stromal edema. One month later, the patient had a clear cornea, persistent complete graft adhesion, and visual acuity of 0.9. CONCLUSION: The discovery of free roll in the anterior chamber after DMEK surgery constitutes the most complex form of graft detachment. Corneal edema as well as the arrangement of the different intraocular structures are conditions to be considered for the surgical resolution of this complication. In many cases, surgical repositioning of the graft is feasible, which means saving costs without the need to use new donor corneal tissues.


Asunto(s)
Edema Corneal , Queratoplastia Endotelial de la Lámina Limitante Posterior , Femenino , Humanos , Anciano de 80 o más Años , Lámina Limitante Posterior/cirugía , Endotelio Corneal , Edema Corneal/etiología , Edema Corneal/cirugía , Cámara Anterior/cirugía , Edema
12.
Sci Rep ; 14(1): 3881, 2024 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-38365883

RESUMEN

Primary angle closure disease (PACD) is a major cause of blindness worldwide. It has a high prevalence in East Asia, especially in China, which leads to a higher incidence of blindness than open-angle glaucoma. The aim of this study was to directly observe the circumlental space (CLS) in laser peripheral iridotomized eyes with PACD and to determine whether this structure plays a role in the pathogenesis of PACD. Fifty eyes of 50 patients with PACD, who had received laser peripheral iridotomy performed with neodymium:yttrium-aluminum-garnet were recruited from glaucoma clinics from March 2021 to May 2022, including 17 primary angle closure suspect (PACS), 16 primary angle closure (PAC) and 17 primary angle closure glaucoma (PACG). They were classified into two groups based on whether the ciliary process and the crystalline lens equator were in contact using slit-lamp photograph: the attached group and the unattached group. The demographic, clinical characteristics and anterior segment parameters measured from ultrasound biomicroscopy were compared between the attached group and the unattached group. Thirty-three eyes were assigned to the attached group and 17 eyes belonged to the unattached group. In the unattached group, the mean CLS was 0.10 ± 0.07 mm. No significant differences were identified between the different diagnosis groups in age, sex, best-corrected visual acuity, intraocular pressure, white-to-white, axial length, central corneal thickness, anterior chamber depth, flat keratometry, steep keratometry or iridotomy diameter (p > 0.05). The unattached group had shorter trabecular-ciliary process distance (p = 0.021) and larger ciliary process area (p = 0.001) compared with the attached group. Small CLS and its potential effect (partial ciliary block) might be considered as one of the mechanisms of PACD.


Asunto(s)
Glaucoma de Ángulo Cerrado , Glaucoma de Ángulo Abierto , Humanos , Segmento Anterior del Ojo/patología , Iris/cirugía , Iris/patología , Glaucoma de Ángulo Abierto/patología , Glaucoma de Ángulo Cerrado/patología , Cámara Anterior/diagnóstico por imagen , Cámara Anterior/cirugía , Cámara Anterior/patología , Presión Intraocular , Ceguera/patología
13.
Indian J Ophthalmol ; 72(4): 565-570, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38189524

RESUMEN

PURPOSE: To compare postoperative cosmesis, mydriasis, fundus visibility, and anterior chamber depth (ACD) in congenital and traumatic iris defects after single-pass four-throw pupilloplasty (SFTP). SETTINGS AND DESIGN: Hospital-based non-randomized interventional study. METHODS: SFTP was done along with phacoemulsification in six patients each with congenital and traumatic iris defects, and the patients were followed for a minimum period of 3 months. The postoperative pupil shape, size, mydriasis, and ACD were compared between the two groups. RESULTS: Tissue approximation was successful in 11 out of 12 patients (91.7%), whereas it failed to do so in one patient with traumatic iris tear (8.3%). A central round pupil was attained in all six patients with congenital defects (group 1), whereas in the traumatic group (group 2), a central round pupil was attained in four cases. Group 1 did not show a significant reduction in horizontal pupil diameter, but group 2 had a significant reduction in pupil diameter postoperatively. Mydriasis and fundus visibility were satisfactory in all cases. There was a significant deepening of ACD in both groups. CONCLUSION: Traumatic mydriasis usually requires SFTP at two opposite poles to achieve a central pupil with a significant reduction in pupil size, whereas congenital coloboma requires SFTP to be done at the site of coloboma with occasional enlargement at the opposite pole if the pupil is eccentric.


Asunto(s)
Extracción de Catarata , Coloboma , Midriasis , Humanos , Midriasis/diagnóstico , Midriasis/etiología , Midriasis/cirugía , Coloboma/cirugía , Iris/cirugía , Pupila , Cámara Anterior/cirugía
14.
Cornea ; 43(4): 534-536, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38166177

RESUMEN

PURPOSE: The aim of this study was to describe the feasibility and applicability of a reverse 4-throw (RFT) pupilloplasty technique for endothelial keratoplasty. METHODS: In RFT, the 9-0 polypropylene suture needle and a 26-Gauge needle pierce the iris tissue from the posterior surface to emerge on the anterior surface along the proximal and distal portion of iris tissue to be apposed, respectively. The 9-0 needle is threaded into the barrel of a 26-Gauge needle and is withdrawn from the eye. The suture loop is withdrawn and the suture end is passed through the loop 4 times. Both suture ends are pulled, which leads to the sliding of the loop inside the eye, thereby apposing the iris tissue with the knot lying on the posterior surface. RESULTS: The procedure was performed in 11 eyes of 11 patients who were scheduled to undergo an endothelial keratoplasty procedure. The anterior segment optical coherence tomography image of the RFT pupilloplasty did not denote any presence of the suture in the anterior chamber or along the anterior surface of the iris plane. No incidence of primary graft failure or graft rejection during the entire follow-up period was reported in any of the eyes. CONCLUSIONS: RFT serves as an effective technique for performing pupilloplasty in endothelial keratoplasty cases without the presence of a knot or suture tail in the anterior chamber.


Asunto(s)
Trasplante de Córnea , Procedimientos de Cirugía Plástica , Humanos , Iris/cirugía , Procedimientos Quirúrgicos Oftalmológicos , Cámara Anterior/cirugía , Técnicas de Sutura
15.
J Fr Ophtalmol ; 47(2): 103979, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37858497

RESUMEN

PURPOSE: To compare the efficacy of three different gases for intraocular tamponade: 100% air, 10% perfluoropropane (C3F8), and 10% sulfur hexafluoride (SF6), in Descemet's membrane endothelial keratoplasty (DMEK). MATERIALS AND METHODS: The medical records of 138 patients who underwent DMEK were reviewed retrospectively, with the primary outcome being the rebubbling rate in the first week following surgery. Other clinical outcomes, such as best-corrected visual acuity (BCVA), central corneal thickness (CCT), incidence of rebubbling after the first week, endothelial cell density (ECD), graft detachment, graft failure, pupillary block, and intraocular pressure (IOP) changes were also analyzed. RESULTS: Of the 138 patients, 57 were in group 1 (treated with air), 44 in group 2 (treated with 10% C3F8), and 37 in group 3 (treated with 10% SF6). Group 3 showed significantly lower rates of graft detachment and rebubbling compared to groups 1 and 2 (P<0.001). However, there was no significant difference in postoperative BCVA among the groups. At one year, the mean endothelial cell loss was 32% in group 1, 30% in group 2, and 33% in group 3 (P=0.715). One patient in group 1 experienced pupillary block and increased IOP, while there were no such occurrences in the other groups. There was no difference between the groups in terms of graft failure. CONCLUSION: The use of 10% SF6 in DMEK surgery may be a good option due to its efficacy in preventing graft detachment, low rebubbling rate, and potential for minimizing complications.


Asunto(s)
Queratoplastia Endotelial de la Lámina Limitante Posterior , Distrofia Endotelial de Fuchs , Humanos , Lámina Limitante Posterior/cirugía , Gases , Estudios Retrospectivos , Queratoplastia Endotelial de la Lámina Limitante Posterior/efectos adversos , Agudeza Visual , Endotaponamiento , Cámara Anterior/cirugía , Distrofia Endotelial de Fuchs/cirugía , Hexafluoruro de Azufre , Endotelio Corneal/trasplante
16.
J Ocul Pharmacol Ther ; 40(1): 100-107, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37851489

RESUMEN

Background/Aims: The current standard of care to perform an anterior chamber paracentesis involves the use of a multipurpose market needle and syringe. The use of standard needles for this purpose may result in injury to the patient due to increased force with insertion and increased globe displacement during the procedure. This research investigates the current market needle characteristics and the impact of each needle characteristic on force. Methods: Several comparative trials were conducted to evaluate the needles. Needle characteristics of interest were gauge, primary bevel angle, number of bevels in the lancet, and needle hub geometry. Measurements of corneal insertion forces were made using a synthetic thermoplastic polyurethane medium, and bovine and porcine models. Needle safety was investigated with corneal abrasion experiments. Results: Reduced insertion force was observed with lower lancet primary angle. There was no difference based on the number of bevels in the lancet. Rounded hub geometry had minimal distribution to the corneal epithelium. Conclusions: Needle characteristics impact the force needed for needle insertion into the tissue. Since higher force can lead to increased risk and less efficiency during the procedure, reducing this force may improve the outcomes of the procedure. Needle entry can be reduced by designing an improved needle that includes a lower gauge and reduced primary angle of the lancet.


Asunto(s)
Agujas , Paracentesis , Animales , Bovinos , Humanos , Porcinos , Paracentesis/efectos adversos , Modelos Animales , Cámara Anterior/cirugía
17.
JAMA Ophthalmol ; 142(1): 76-77, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38095889

RESUMEN

A 62-year-old woman presented with painless vision reduction and eye redness in the right eye for a week. Nine months after keratoplasty, she presented with diffuse tiny nodules all over the iris and a dense opacity in the anterior vitreous body. What would you do next?


Asunto(s)
Cámara Anterior , Trasplante de Córnea , Humanos , Cámara Anterior/diagnóstico por imagen , Cámara Anterior/cirugía , Trasplante de Córnea/efectos adversos , Iris , Femenino , Persona de Mediana Edad , Complicaciones Posoperatorias
18.
Eur J Ophthalmol ; 34(2): NP17-NP21, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37853712

RESUMEN

PURPOSE: To report a case of inadvertent cystic filtering bleb in a patient with scleral fixated intraocular lens (SFIOL) implantation 7 years after initial procedure. CASE PRESENTATION: A 14-year-old boy underwent lensectomy, vitrectomy and a sutured rigid SFIOL for microspherophakia in the right eye. Seven years later, the patient presented with hypotony related ocular changes. Examination revealed an inadvertent cystic filtering bleb at the scleral section. Anterior segment optical coherence tomography (ASOCT) revealed gap in inner lips of the scleral wound, bridged by a thin strip of scleral tissue. A conservative management with bandage contact lens (BCL) failed after an initial improvement. Injection of trypan blue dye in the anterior chamber confirmed the presence and site of wound filtration. Surgical closure of the fistula was done and patient showed both structural and visual improvement. CONCLUSION: Meticulous wound construction and water tight closure at the end of the surgery can avoid such complications. ASOCT can be helpful in diagnosing the area of fistula. A conservative management with BCL can help by tamponading the filtering bleb. However, in unresponsive cases, surgical closure of the fistula is recommended to improve the hypotony-related changes.


Asunto(s)
Fístula , Glaucoma , Lentes Intraoculares , Masculino , Humanos , Adolescente , Implantación de Lentes Intraoculares/métodos , Glaucoma/cirugía , Cámara Anterior/cirugía , Esclerótica/cirugía , Fístula/cirugía , Complicaciones Posoperatorias/cirugía , Estudios Retrospectivos
20.
JAMA Ophthalmol ; 141(11): e232468, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37971509

RESUMEN

This case report discusses the dislocation of a Descemet stripping endothelial keratoplasty (DSEK) lenticule in a man aged 82 years who underwent DSEK for pseudophakic bullous keratopathy.


Asunto(s)
Enfermedades de la Córnea , Queratoplastia Endotelial de la Lámina Limitante Posterior , Humanos , Enfermedades de la Córnea/cirugía , Endotelio Corneal , Cámara Anterior/cirugía , Lámina Limitante Posterior/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA