Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 1.388
1.
JACC Cardiovasc Interv ; 17(9): 1079-1090, 2024 May 13.
Article En | MEDLINE | ID: mdl-38749587

Tetralogy of Fallot (TOF) is the most common form of cyanotic congenital heart disease. Palliative procedures, either surgical or transcatheter, aim to improve oxygen saturation, affording definitive procedures at a later stage. Transcatheter interventions have been used before and after surgical palliative or definitive repair in children and adults. This review aims to provide an overview of the different catheter-based interventions for TOF across all age groups, with an emphasis on palliative interventions, such as patent arterial duct stenting, right ventricular outflow tract stenting, or balloon pulmonary valvuloplasty in infants and children and transcatheter pulmonary valve replacement in adults with repaired TOF, including the available options for a large, dilated native right ventricular outflow tract.


Balloon Valvuloplasty , Cardiac Catheterization , Heart Valve Prosthesis Implantation , Palliative Care , Stents , Tetralogy of Fallot , Humans , Tetralogy of Fallot/surgery , Tetralogy of Fallot/diagnostic imaging , Tetralogy of Fallot/physiopathology , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Infant , Treatment Outcome , Age Factors , Child, Preschool , Child , Adult , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Adolescent , Infant, Newborn , Young Adult , Cardiac Surgical Procedures/adverse effects , Risk Factors , Female , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Pulmonary Valve/physiopathology , Male , Hemodynamics , Middle Aged , Recovery of Function
2.
J Am Heart Assoc ; 13(10): e033601, 2024 May 21.
Article En | MEDLINE | ID: mdl-38761069

BACKGROUND: The aims of this study were to understand the incidence and outcomes of patients with cardiogenic shock (CS) due to severe aortic stenosis (AS), and the impact of conventional treatment strategies in this population. METHODS AND RESULTS: All patients admitted to the Cleveland Clinic cardiac intensive care unit between January 1, 2010 and December 31, 2021 with CS were retrospectively identified and categorized into those with CS in the setting of severe AS versus CS without AS. The impact of various treatment strategies on mortality was further assessed. We identified 2754 patients with CS during the study period, of whom 216 patients (8%) had CS in the setting of severe AS. Medical management was associated with the highest 30-day mortality when compared with either balloon aortic valve replacement or aortic valve replacement (surgical or transcatheter aortic valve replacement) (hazard ratio, 3.69 [95% CI, 2.04-6.66]; P<0.0001). Among patients who received transcatheter therapy, 30-day mortality was significantly higher in patients who received balloon aortic valvuloplasty versus transcatheter aortic valve replacement (26% versus 4%, P=0.02). Both surgical and transcatheter aortic valve replacement had considerably lower mortality than medical management and balloon aortic valvuloplasty at 30 days and 1 year (P<0.05 for both comparisons). CONCLUSIONS: CS due to severe AS is associated with high in-hospital and 30-day mortality, worse compared with those with CS without AS. In suitable patients, urgent surgical aortic valvuloplasty or transcatheter aortic valve replacement is associated with favorable short- and long-term outcomes. Although balloon aortic valvuloplasty may be used to temporize patients with CS in the setting of severe AS, mortality is ≈50% if not followed by definitive aortic valve replacement within 90 days.


Aortic Valve Stenosis , Severity of Illness Index , Shock, Cardiogenic , Transcatheter Aortic Valve Replacement , Humans , Shock, Cardiogenic/therapy , Shock, Cardiogenic/etiology , Shock, Cardiogenic/mortality , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Male , Female , Retrospective Studies , Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Aged, 80 and over , Balloon Valvuloplasty/mortality , Balloon Valvuloplasty/adverse effects , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Risk Factors , Time Factors , Incidence
4.
Tex Heart Inst J ; 51(1)2024 Apr 26.
Article En | MEDLINE | ID: mdl-38665003

Klippel-Feil syndrome, characterized by congenital fusion of any 2 or more cervical vertebrae, is a rare disorder in which skeletal and other organ system-related abnormalities have been reported. This article reports a case of mitral valve regurgitation in a patient with Klippel-Feil syndrome and related thoracic deformity who underwent mitral valvuloplasty. Postoperatively, the mitral valve regurgitation disappeared, and there has been no recurrence for 3 years. This case highlights mitral valvuloplasty via median sternotomy as an excellent treatment for mitral valve regurgitation in a patient with thoracic deformity related to Klippel-Feil syndrome.


Klippel-Feil Syndrome , Mitral Valve Insufficiency , Humans , Klippel-Feil Syndrome/complications , Klippel-Feil Syndrome/diagnosis , Klippel-Feil Syndrome/surgery , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/diagnosis , Treatment Outcome , Sternotomy , Male , Mitral Valve/surgery , Mitral Valve/abnormalities , Mitral Valve/diagnostic imaging , Tomography, X-Ray Computed , Balloon Valvuloplasty , Female , Adult
5.
Catheter Cardiovasc Interv ; 103(6): 1004-1014, 2024 May.
Article En | MEDLINE | ID: mdl-38577939

INTRODUCTION: Bicuspid aortic valve (BAV) stenosis is a complex anatomical scenario for transcatheter aortic valve implantation (TAVI). Favorable short-term clinical outcomes have been reported with TAVI in this setting, but long-term data are scarce. METHODS: We retrospectively included, in a single-center registry, patients with BAV stenosis who underwent TAVI before 2020. We compared patients treated with self-expanding valves (SEV) versus balloon-expandable valves (BEV). The primary endpoint was a composite of all-cause mortality, stroke and need for aortic valve (AV) reintervention at 3 years. Secondary endpoints included each component of the primary endpoint, cardiovascular mortality, permanent pacemaker implantation (PPI) rate, mean gradient and ≥moderate paravalvular leak (PVL) rate. RESULTS: A total of 150 consecutive patients (SEV = 83, BEV = 67) were included. No significant differences were reported between SEV and BEV groups for the primary composite endpoint (SEV 35.9% vs. BEV 32%, p = 0.66), neither for clinical secondary endpoints (all-cause mortality SEV 28.1% vs. BEV 28%, p = 0.988; cardiovascular mortality SEV 14.1% vs. BEV 20%, p = 0.399; stroke SEV 12.5% vs. BEV 6%, p = 0.342; need for AV reintervention SEV 0% vs. BEV 0%; PPI SEV 28.1% vs. BEV 24%, p = 0.620). A lower mean gradient persisted up to 3 years in the SEV group (SEV 8.8 ± 3.8 mmHg vs. BEV 10.7 ± 3.2 mmHg, p = 0.063), while no significant difference was found in the rate of ≥ moderate PVL (SEV 3/30 vs. BEV 0/25, p = 0.242). CONCLUSIONS: In this single center registry, we observed favorable 3-year clinical outcomes in nonselected BAV patients treated with different generation devices, without significant differences between patients receiving SEV or BEV.


Aortic Valve Stenosis , Balloon Valvuloplasty , Bicuspid Aortic Valve Disease , Heart Valve Prosthesis , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Male , Female , Retrospective Studies , Treatment Outcome , Bicuspid Aortic Valve Disease/physiopathology , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/mortality , Bicuspid Aortic Valve Disease/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Time Factors , Aged , Balloon Valvuloplasty/adverse effects , Balloon Valvuloplasty/mortality , Aged, 80 and over , Risk Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/abnormalities , Recovery of Function , Hemodynamics , Risk Assessment
6.
Circ Cardiovasc Interv ; 17(5): e013608, 2024 May.
Article En | MEDLINE | ID: mdl-38529637

BACKGROUND: Comparative data on transcatheter self-expanding ACURATE neo2 (NEO2) and balloon-expandable SAPIEN 3 Ultra prostheses in technically challenging anatomy of severe aortic valve calcified aortic annuli are scarce. METHODS: A total of 1987 patients with severe native aortic stenosis treated with the self-expanding NEO2 (n=1457) or balloon-expandable SAPIEN 3 Ultra (n=530) from January 2017 to April 2023 were evaluated. The primary end point was procedural outcome according to the Valve Academic Research Consortium 3 definitions. Propensity matching defined 219 pairs with severe calcification (calcium density cutoff, 758 AU/cm2) of the native aortic valve. RESULTS: Technical success (90.4% versus 91.8%; risk difference, 1.4% [95% CI, -4.4 to -7.2]; P=0.737) and device success at 30 days (80.8% versus 75.8%; risk difference, -5.0% [95% CI, -13.2 to 3.1]; P=0.246) were comparable between NEO2 and SAPIEN 3 Ultra. The rate of severe prosthesis-patient mismatch (1.1% versus 10.1%; risk difference, 10.0% [95% CI, 4.0-13.9]; P<0.001) and mean transvalvular gradient ≥20 mm Hg (2.8% versus 14.3%; risk difference, 11.5% [95% CI, 5.8-17.1]; P<0.001) was lower with NEO2. The rate of more-than-mild paravalvular leakage or valve-in-valve due to paravalvular leakage was significantly higher (6.2% versus 0.0%; risk difference, 6.2% [95% CI, -10.1 to -2.7]; P=0.002), and there was a tendency for a higher rate of device embolization or migration (1.8% versus 0.0%; risk difference, -1.8% [95% CI, -4.1 to 0.4]; P=0.123) with NEO2. Multivarate regression revealed no independent impact of transcatheter heart valve selection on device success (odds ratio, 0.93 [95% CI, 0.48-1.77]; P=0.817). CONCLUSIONS: In patients with severely calcified annuli, supraannular implantation of NEO2 showed hemodynamic advantages. Nevertheless, NEO2 was associated with a higher incidence of relevant paravalvular leakage and a numerically higher rate of device embolization than SAPIEN 3 Ultra in this particular patient group.


Aortic Valve Stenosis , Aortic Valve , Calcinosis , Heart Valve Prosthesis , Prosthesis Design , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Male , Female , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/pathology , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Calcinosis/diagnostic imaging , Calcinosis/surgery , Treatment Outcome , Risk Factors , Time Factors , Risk Assessment , Retrospective Studies , Propensity Score , Recovery of Function , Balloon Valvuloplasty/adverse effects , Hemodynamics
7.
Circ Cardiovasc Interv ; 17(5): e013898, 2024 May.
Article En | MEDLINE | ID: mdl-38533653

BACKGROUND: Acute aortic regurgitation is life-threatening with few nonsurgical options for immediate stabilization. We propose Trans-Aortic Balloon to Ease Regurgitation Applying Counter-Pulsation (TABERNACL), a simple, on-table temporary valve using commercially available equipment to temporize acute severe aortic regurgitation. METHODS: We hypothesize that an appropriately sized commercial balloon dilatation catheter-straddling the aortic annulus and connected to a counterpulsation console-can serve as a temporizing valve to restore hemodynamic stability in acute aortic regurgitation. We performed benchtop testing of valvuloplasty, angioplasty, and sizing balloons as counterpulsation balloons. TABERNACL was assessed in vivo in a porcine model of acute aortic regurgitation (n=8). We also tested a static undersized, continuously inflated transvalvular balloon as a spacer intended physically to obstruct the regurgitant orifice. RESULTS: Benchtop testing identified that Tyshak II and PTS sizing (NuMed Braun) balloon catheters performed adequately as temporary valves (ie, complete inflation and deflation with each cycle) and resisted fatigue, in contrast to others. When TABERNACL was used in the acute severe regurgitation animals, there was immediate hemodynamic improvement, with a significant 35% increase in diastolic aortic pressure by 16 mm Hg ([95% CI, 7-25] P=0.0056), 34% reduction in left ventricular end-diastolic pressure by -7 mm Hg ([95% CI, -10 to -5] P=0.0006), improvement in the aortic diastolic index by 0.28 ([95% CI, 0.18-0.39] P=0.0009), and reversal of electrocardiographic myocardial ischemia. As an alternative, static balloon inflation across the aortic valve stabilized regurgitation hemodynamics at the expense of a new aortic gradient and caused excessive ectopy from balloon movement in the left ventricular outflow tract. CONCLUSIONS: TABERNACL improves hemodynamics and reduces coronary ischemia by electrocardiography in animals with acute severe aortic regurgitation. TABERNACL valves obstruct the diastolic regurgitant orifice without systolic obstruction. This may prove a lifesaving bridge to definitive valve replacement therapy.


Aortic Valve Insufficiency , Balloon Valvuloplasty , Disease Models, Animal , Hemodynamics , Animals , Hemodynamics/drug effects , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/diagnostic imaging , Sus scrofa , Aortic Valve/physiopathology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Equipment Design , Recovery of Function , Acute Disease , Cardiac Catheters , Time Factors , Severity of Illness Index , Ventricular Function, Left/drug effects
8.
JACC Cardiovasc Interv ; 17(8): 1032-1044, 2024 Apr 22.
Article En | MEDLINE | ID: mdl-38456883

BACKGROUND: The fifth-generation SAPIEN 3 Ultra Resilia valve (S3UR) incorporates several design changes as compared with its predecessors, the SAPIEN 3 (S3) and SAPIEN 3 Ultra (S3U) valves, including bovine leaflets treated with a novel process intended to reduce structural valve deterioration via calcification, as well as a taller external skirt on the 29-mm valve size to reduce paravalvular leak (PVL). The clinical performance of S3UR compared with S3 and S3U in a large patient population has not been previously reported. OBJECTIVES: The aim of this study was to compare S3UR to S3/S3U for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR). METHODS: Patients enrolled in the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between January 1, 2021, and June 30, 2023, who underwent TAVR with S3UR or S3U/S3 valve platforms were propensity-matched and evaluated for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes. RESULTS: 10,314 S3UR patients were propensity matched with 10,314 patients among 150,539 S3U/S3 patients. At 30 days, there were no statistically significant differences in death, stroke, or bleeding, but a numerically higher hospital readmission rate in the S3UR cohort (8.5% vs 7.7%; P = 0.04). At discharge, S3UR patients exhibited significantly lower mean gradients (9.2 ± 4.6 mm Hg vs 12.0 ± 5.7 mm Hg; P < 0.0001) and larger aortic valve area (2.1 ± 0.7 cm2 vs 1.9 ± 0.6 cm2; P < 0.0001) than patients treated with S3/S3U. The 29-mm valve size exhibited significant reduction in mild PVL (5.3% vs 9.4%; P < 0.0001). CONCLUSIONS: S3UR TAVR is associated with lower mean gradients and lower rates of PVL than earlier generations of balloon expandable transcatheter heart valve platforms.


Aortic Valve Stenosis , Aortic Valve , Balloon Valvuloplasty , Heart Valve Prosthesis , Prosthesis Design , Recovery of Function , Registries , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Balloon Valvuloplasty/adverse effects , Hemodynamics , Postoperative Complications/etiology , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United States
10.
Catheter Cardiovasc Interv ; 103(6): 1035-1041, 2024 May.
Article En | MEDLINE | ID: mdl-38545668

A distinctive complication with balloon-expandable (BE) THV platforms such as the Edwards Sapien (Edwards Lifescience) is the possibility of balloon rupture during THV deployment. Balloon rupture is a rare occurrence that can result in stroke due to fragment embolism, incomplete THV expansion, and/or vascular injury upon retrieval of the balloon. Careful evaluation of preoperative computed tomography is essential to identify high-risk cases. While annular and left ventricular outflow tract (LVOT) calcification are widely acknowledged as common risks for balloon injury, it's essential to note that balloon injury can manifest at various anatomical sites. In this review, we discuss the mechanism behind balloon rupture, methods to identify cases at a heightened risk of balloon injury, approaches to mitigate the risk of rupture, and percutaneous retrieval strategies.


Balloon Valvuloplasty , Equipment Failure , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Balloon Valvuloplasty/adverse effects , Balloon Valvuloplasty/instrumentation , Cardiac Catheters , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome
11.
J Invasive Cardiol ; 36(4)2024 Apr.
Article En | MEDLINE | ID: mdl-38412440

An 83-year-old man with symptomatic severe aortic valve stenosis with severe ventricular dysfunction underwent valvuloplasty with a 25-mm NuCLEUS-X balloon (B. Braun Interventional Systems) and percutaneous coronary intervention of the left main and circumflex arteries (left anterior descending artery presented a chronic total occlusion without viability of this territory) before being referred for transcatheter aortic valve replacement.


Aortic Valve Stenosis , Balloon Valvuloplasty , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Male , Humans , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aorta, Thoracic/surgery , Treatment Outcome , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Prosthesis Design , Risk Factors
12.
Pediatr Cardiol ; 45(4): 722-728, 2024 Apr.
Article En | MEDLINE | ID: mdl-38411710

Pulmonary balloon valvuloplasty (PBV) is the treatment of choice for subjects with isolated pulmonary valve stenosis (IPS). The purpose of this study was to define fetal echocardiographic features associated with an inpatient PBV prior to newborn hospital discharge and characterize resource utilization of IPS fetuses among participating centers. Six center, retrospective case series of singleton fetuses identified between 2010 and 2020 with IPS. Third-trimester echocardiogram data was compared with postnatal data, included pulmonary valve Doppler velocities, pulmonary valve insufficiency and ductus arteriosus flow direction. Comparison between subjects who underwent inpatient PBV during their newborn hospital admission versus those infants referred for outpatient PBV after initial hospital discharge. We analyzed data by logistic regression, student t test and Chi-Square testing with a p value of ≤ 0.05 considered statistically significant. Forty-nine IPS fetuses were identified. Thirty-eight (78%) underwent inpatient PBV at 5 (range 1-58) days and 11 (22%) underwent outpatient PBV at 51.8 (11-174) days. Newborns requiring an inpatient PBV were more likely to have one or more characteristics on 3rd-trimester fetal echocardiogram: left to right or bidirectional ductus arteriosus flow (61% vs 0%), and/or a peak pulmonary valve velocity > 3.0 m/s (odds ratio 16.9, 95% confidence interval 3.02-94.17) with a sensitivity of 90.4% and specificity of 97.7%. Ductus arteriosus flow direction and pulmonary valve peak velocity in the 3rd trimester can successfully predict the need for newborn inpatient PBV. We speculate these findings may be useful in choosing delivery site for the pregnancy complicated by fetal IPS.


Balloon Valvuloplasty , Ductus Arteriosus, Patent , Ductus Arteriosus , Pulmonary Valve Stenosis , Infant , Female , Pregnancy , Humans , Infant, Newborn , Retrospective Studies , Echocardiography , Pregnancy Trimester, Third , Pulmonary Valve Stenosis/diagnostic imaging , Pulmonary Valve Stenosis/surgery , Ultrasonography, Prenatal
13.
Ann Noninvasive Electrocardiol ; 29(1): e13104, 2024 01.
Article En | MEDLINE | ID: mdl-38288512

OBJECTIVE: This study aimed to investigate the structure of the mitral valve in patients undergoing mitral valvuloplasty (MVP) using real-time three-dimensional transesophageal echocardiography (RT-3D-TEE). The main objective was to study the relationship between intraoperative annuloplasty ring size and mitral valve structure dimensions, with a focus on exploring the application value of RT-3D-TEE in MVP. METHODS: A total of 28 patients with degenerative mitral regurgitation (DMR), who underwent MVP between February and September 2022, as well as 12 normal control cases, were enrolled in this study. The MV annulus and leaflets were quantitatively analyzed using MVN software. RESULTS: The DMR group exhibited significantly greater dimensions in various parameters of the mitral valve, including the anterolateral-to-posteromedial diameter (DAlPm ), anterior-to-posterior diameter (DAP ), annulus height (HA ), three-dimensional annulus circumference (CA3D ), two-dimensional annulus area (AA2D ), anterior leaflet area (Aant ), posterior leaflet area (Apost ), anterior leaflet length (Lant ), posterior leaflet length (Lpost ), and tenting volume (Vtent ) compared to the control group. CONCLUSION: Real-time three-dimensional transesophageal echocardiography provides valuable insights into the morphological structure of the mitral valve and lesion location. It can aid in surgical decision-making, validate the success of MVP, and potentially reduce mortality and complications associated with mitral valve repair procedures.


Balloon Valvuloplasty , Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Mitral Valve Insufficiency , Humans , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Electrocardiography , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery
14.
Am Heart J ; 270: 13-22, 2024 Apr.
Article En | MEDLINE | ID: mdl-38253304

BACKGROUND: Safety and feasibility of transcatheter aortic valve replacement (TAVR) without balloon aortic valvuloplasty (BAV) using the SAPIEN 3 balloon-expandable device has been previously demonstrated. The impact on long-term valve hemodynamic performances and outcomes remains however unknown. We evaluate long-term clinical and hemodynamic results according to the implant strategy (direct TAVR vs BAV pre-TAVR) in patients included in the DIRECTAVI randomized trial (NCT02729519). METHODS: Clinical and echocardiographic follow-up until January 2023 was performed for all patients included in the DIRECTAVI trial since 2016 (n = 228). The primary endpoint was incidence of moderate/severe hemodynamic valve deterioration (HVD), according to the Valve Academic Research defined Consortium-3 criteria (increase in mean gradient ≥10 mmHg resulting in a final mean gradient ≥20 mmHg, or new/worsening aortic regurgitation of 1 grade resulting in ≥ moderate aortic regurgitation). RESULTS: Median follow-up was 3.8 (2.2-4.7) years. Mean age at follow-up was 87 ± 6.7 years. No difference in incidence of HVD in the direct implantation group compared to the BAV group was found (incidence of 1.97 per 100 person-years and 1.45 per 100 person-years, respectively, P = 0.6). Prevalence of predicted prothesis-patient mismatch was low (n = 13 [11.4%] in the direct TAVR group vs n = 15 [13.2%] in BAV group) and similar between both groups (P = .7). Major outcomes including death, stroke, hospitalization for heart failure and pacemaker implantation were similar between both groups, (P = .4, P = .7, P = .3, and P = .3 respectively). CONCLUSION: Direct implantation of the balloon-expandable device in TAVR was not associated with an increased risk of moderate/severe HVD or major outcomes up to 6-year follow-up. These results guarantee wide use of direct balloon-expandable valve implantation, when feasible. CLINICAL TRIALS REGISTRATION NUMBER: NCT05140317.


Aortic Valve Insufficiency , Aortic Valve Stenosis , Balloon Valvuloplasty , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aged, 80 and over , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Follow-Up Studies , Aortic Valve Insufficiency/surgery , Treatment Outcome , Time Factors , Prosthesis Design , Balloon Valvuloplasty/adverse effects
15.
J Invasive Cardiol ; 36(1)2024 Jan.
Article En | MEDLINE | ID: mdl-38224293

Congenital tricuspid valve stenosis is extremely rare. We describe 2 cases of patients with adult congenital heart disease with hypoplastic tricuspid valve annulus who were symptomatic from annular- and leaflet-level tricuspid stenosis. The patients underwent transcatheter balloon valvuloplasty with good clinical outcomes. An extensive literature review and analysis of various procedural strategies suggests that percutaneous balloon valvuloplasty may be a reasonable therapeutic choice as a first-line therapy or when open surgical repair is associated with prohibitively high mortality. This procedure can be performed either as a destination therapy or as a bridge to valve replacement.


Balloon Valvuloplasty , Heart Defects, Congenital , Tricuspid Valve Stenosis , Adult , Humans , Constriction, Pathologic , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve Stenosis/diagnosis , Tricuspid Valve Stenosis/surgery
18.
Int J Cardiol ; 400: 131792, 2024 Apr 01.
Article En | MEDLINE | ID: mdl-38244892

BACKGROUND: ACURATE neo2 (Neo2) implantation is performed after systematic Balloon Aortic Valvuloplasty (BAV) in most patients. No reports exist about the feasibility and safety of direct Neo2 transcatheter aortic valve implantation (TAVI) in comparison to the standard practice. AIM: We aimed to identify the patients' baseline anatomical characteristics, procedural, and early post-procedural outcomes in patients treated using Neo2 with and without BAV. METHODOLOGY: This is a retrospective multicentre analysis of 499 patients with severe aortic stenosis who underwent TAVI using Neo2. The comparison was done according to the performance or omission of BAV. Echocardiography and computed tomography were analysed by an independent Core Lab. Propensity score matching (PSM) was performed based on the annular diameter and AV calcium volume, which identified 84 matched pairs. RESULTS: Among the cohort included, 391 (78%) patients received BAV (BAV-yes) and 108 (22%) were not attempted (BAV-no or Direct TAVI). Patients in BAV-no cohort had smaller annular diameter (22.6 vs 23.4 mm; p < 0.001) and lower calcium volume (163 vs 581 mm3; p < 0.001) compared to BAV-yes cohort. In the matched cohort, VARC-3 device technical success was similar (95%) and all other outcome measures were statistically comparable between cohorts. CONCLUSION: Direct TAVI using ACURATEneo2 without pre-TAVI balloon aortic valvuloplasty in patients with mild or less valve calcifications might be feasible and associated with comparable early outcomes compared to patients with similar anatomical features undergoing systematic balloon valvuloplasty.


Aortic Valve Stenosis , Balloon Valvuloplasty , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Balloon Valvuloplasty/methods , Calcium , Treatment Outcome , Retrospective Studies , Prosthesis Design
19.
J Invasive Cardiol ; 36(1)2024 Jan.
Article En | MEDLINE | ID: mdl-38224301

We present a case of a 57-year-old male who underwent bioprosthetic mitral valve replacement (MVR) and developed postoperative cardiogenic shock requiring venoarterial extracorporeal membrane oxygenation (VA ECMO) and Impella 5.5 (Abiomed) hemodynamic support.


Balloon Valvuloplasty , Extracorporeal Membrane Oxygenation , Pulmonary Veins , Male , Humans , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Postoperative Period
...