Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 5.323
1.
Ophthalmic Plast Reconstr Surg ; 40(3): 336-339, 2024.
Article En | MEDLINE | ID: mdl-38738711

PURPOSE: To investigate the relationship between the kinematics of spontaneous blinks and the anterior area of the levator palpebrae superioris muscle in patients with Graves orbitopathy (GO). METHODS: This is a case-control study. The authors measured the margin reflex distance of the upper eyelid (margin reflex distance 1), the kinematics of spontaneous blinks, and the anterior area of levator palpebrae superioris muscle in CT coronal scans of patients with Graves upper eyelid retraction (GO) and a control group. The eye with the greatest margin reflex distance 1 was selected for analysis in each group. RESULTS: A total of 68 participants were included, with 36 in the GO group and 32 in the control group. In the GO group, the mean margin reflex distance 1 measured 6.5 mm, while in the control group, it was 3.9 mm. Almost all parameters related to the closing phase of spontaneous blinking activity, including amplitude, velocity, blinking rate, and interblink time, did not differ between the two groups. However, the effectiveness of the blink's amplitude (ratio of blink amplitude to margin reflex distance 1) and the main sequence (relationship between amplitude and velocity) were significantly reduced in the GO group compared with the control group. The area of the levator palpebrae superioris muscle was significantly larger in GO than in controls, with 71.4% of patients' muscles outside of the maximum range of the controls. CONCLUSIONS: In patients with GO, there is a reduction in blinking effectiveness, also known as blink lagophthalmos, which is a factor in the common occurrence of ocular surface symptoms. The increase in velocity with amplitude is also reduced in GO.


Blinking , Eyelids , Graves Ophthalmopathy , Oculomotor Muscles , Humans , Blinking/physiology , Female , Graves Ophthalmopathy/physiopathology , Graves Ophthalmopathy/complications , Graves Ophthalmopathy/diagnosis , Male , Middle Aged , Oculomotor Muscles/physiopathology , Adult , Case-Control Studies , Eyelids/physiopathology , Eyelid Diseases/physiopathology , Eyelid Diseases/diagnosis , Aged , Tomography, X-Ray Computed , Lagophthalmos
2.
Transl Vis Sci Technol ; 13(5): 2, 2024 May 01.
Article En | MEDLINE | ID: mdl-38696181

Purpose: Currently, no solution exists to restore natural eyelid kinematics for patients with complete eyelid paralysis due to loss of function of both the levator palpebrae superioris and orbicularis oculi. These rare cases are prone to complications of chronic exposure keratopathy which may lead to corneal blindness. We hypothesized that magnetic force could be used to fully automate eyelid movement in these cases through the use of eyelid-attached magnets and a spectacle-mounted magnet driven by a programmable motor (motorized magnetic levator prosthesis [MMLP]). Methods: To test this hypothesis and establish proof of concept, we performed a finite element analysis (FEA) for a prototype MMLP to check the eyelid-opening force generated by the device and verified the results with experimental measurements in a volunteer with total bidirectional eyelid paralysis. The subject was then fitted with a prototype to check the performance of the device and its success. Results: With MMLP, eye opening was restored to near normal, and blinking was fully automated in close synchrony with the motor-driven polarity reversal, with full closure on the blink. The device was well tolerated, and the participant was pleased with the comfort and performance. Conclusions: FEA simulation results conformed to the experimentally observed trend, further supporting the proof of concept and design parameters. This is the first viable approach in human patients with proof of concept for complete reanimation of a bidirectionally paretic eyelid. Further study is warranted to refine the prototype and determine the feasibility and safety of prolonged use. Translational Relevance: This is first proof of concept for our device for total bidirectional eyelid paralysis.


Blinking , Eyelids , Proof of Concept Study , Humans , Blinking/physiology , Eyelids/physiopathology , Eyelid Diseases/physiopathology , Eyelid Diseases/therapy , Oculomotor Muscles/physiopathology , Finite Element Analysis , Biomechanical Phenomena , Prostheses and Implants , Prosthesis Design , Magnets , Male
4.
Clin Neurophysiol ; 162: 165-173, 2024 Jun.
Article En | MEDLINE | ID: mdl-38642482

OBJECTIVE: The current study examined the efficacy of the facial corticobulbar motor evoked potentials (FCoMEPs) and blink reflex (BR) on predicting postoperative facial nerve function during cerebellopontine angle (CPA) tumor surgery. METHODS: Data from 110 patients who underwent CPA tumor resection with intraoperative FCoMEPs and BR monitoring were retrospectively reviewed. The association between the amplitude reduction ratios of FCoMEPs and BR at the end of surgery and postoperative facial nerve function was determined. Subsequently, the optimal threshold of FCoMEPs and BR for predicting postoperative facial nerve dysfunction were determined by receiver operating characteristic curve analysis. RESULTS: Valid BR was record in 103 of 110 patients, whereas only 43 patients successfully recorded FCoMEP in orbicularis oculi muscle. A reduction over 50.3% in FCoMEP (O. oris) amplitude was identified as a predictor of postoperative facial nerve dysfunction (sensitivity, 77.1%; specificity, 83.6%). BR was another independent predictor of postoperative facial nerve deficit with excellent predictive performance, especially eyelid closure function. Its optimal cut-off value for predicting long-term postoperative eyelid closure dysfunction was was 51.0% (sensitivity, 94.4%; specificity, 94.4%). CONCLUSIONS: BR can compensate for the deficiencies of the FCoMEPs. The combination of BR and FCoMEPs can be used in CPA tumor surgery. SIGNIFICANCE: The study first proposed an optimal cut-off value of BR amplitude deterioration (50.0%) for predicting postoperative eyelid closure deficits in patients undergoing CPA tumor surgery.


Blinking , Evoked Potentials, Motor , Humans , Male , Female , Blinking/physiology , Middle Aged , Adult , Evoked Potentials, Motor/physiology , Aged , Retrospective Studies , Facial Nerve/physiopathology , Predictive Value of Tests , Cerebellopontine Angle/surgery , Cerebellopontine Angle/physiopathology , Young Adult , Neuroma, Acoustic/surgery , Neuroma, Acoustic/physiopathology , Intraoperative Neurophysiological Monitoring/methods , Adolescent , Cerebellar Neoplasms/surgery , Cerebellar Neoplasms/physiopathology , Postoperative Complications/physiopathology , Postoperative Complications/diagnosis
5.
eNeuro ; 11(4)2024 Apr.
Article En | MEDLINE | ID: mdl-38627063

Trace eyeblink conditioning (TEBC) has been widely used to study associative learning in both animals and humans. In this paradigm, conditioned responses (CRs) to conditioned stimuli (CS) serve as a measure for retrieving learned associations between the CS and the unconditioned stimuli (US) within a trial. Memory consolidation, that is, learning over time, can be quantified as an increase in the proportion of CRs across training sessions. However, how hippocampal oscillations differentiate between successful memory retrieval within a session and consolidation across TEBC training sessions remains unknown. To address this question, we recorded local field potentials (LFPs) from the rat dorsal hippocampus during TEBC and investigated hippocampal oscillation dynamics associated with these two functions. We show that transient broadband responses to the CS were correlated with memory consolidation, as indexed by an increase in CRs across TEBC sessions. In contrast, induced alpha (8-10 Hz) and beta (16-20 Hz) band responses were correlated with the successful retrieval of the CS-US association within a session, as indexed by the difference in trials with and without CR.


Conditioning, Eyelid , Hippocampus , Memory Consolidation , Mental Recall , Rats, Long-Evans , Hippocampus/physiology , Male , Conditioning, Eyelid/physiology , Animals , Memory Consolidation/physiology , Mental Recall/physiology , Association Learning/physiology , Rats , Conditioning, Classical/physiology , Blinking/physiology
6.
Proc Natl Acad Sci U S A ; 121(15): e2310291121, 2024 Apr 09.
Article En | MEDLINE | ID: mdl-38564641

Humans blink their eyes frequently during normal viewing, more often than it seems necessary for keeping the cornea well lubricated. Since the closure of the eyelid disrupts the image on the retina, eye blinks are commonly assumed to be detrimental to visual processing. However, blinks also provide luminance transients rich in spatial information to neural pathways highly sensitive to temporal changes. Here, we report that the luminance modulations from blinks enhance visual sensitivity. By coupling high-resolution eye tracking in human observers with modeling of blink transients and spectral analysis of visual input signals, we show that blinking increases the power of retinal stimulation and that this effect significantly enhances visibility despite the time lost in exposure to the external scene. We further show that, as predicted from the spectral content of input signals, this enhancement is selective for stimuli at low spatial frequencies and occurs irrespective of whether the luminance transients are actively generated or passively experienced. These findings indicate that, like eye movements, blinking acts as a computational component of a visual processing strategy that uses motor behavior to reformat spatial information into the temporal domain.


Blinking , Eye Movements , Humans , Photic Stimulation , Visual Perception/physiology , Vision, Ocular
7.
Lab Chip ; 24(8): 2327-2334, 2024 Apr 16.
Article En | MEDLINE | ID: mdl-38563256

The eyes provide rich physiological information and offer diagnostic potential as a sensing site, and probing tear constituents via the wearable contact lens could be explored for healthcare monitoring. Herein, we propose a novel adhesive contrast contact lens platform that can split tear film by natural means of tear secretion and blinking. The adhesive contrast is realized by selective grafting of a lubricant onto a polydimethylsiloxane (PDMS)-based contact lens, leading to high pinning zones on a non-adhesive background. The difference in contact angle hysteresis facilitates the liquid splitting. Further, the method offers control over the droplet volume by controlling the zone dimension. The adhesive contrast contact lens is coupled with fluorescent spectroscopic as well as colorimetric techniques to realize its potential as a diagnostic platform. The adhesive contrast contact lens is exploited to detect the level of lactoferrin in tear by sensitizing split droplets with Tb3+ ions. The adhesive contrast contact lens integrated with a fluorescence spectrometer was able to detect the lactoferrin level up to a concentration of 0.25 mg mL-1. Additionally, a colorimetric detection based on the fluorescence of the lactoferrin-terbium complex is demonstrated for the measurement of lactoferrin, with a limit of detection in the physiological range up to 0.5 mg mL-1.


Contact Lenses, Hydrophilic , Lactoferrin/analysis , Eye , Tears/chemistry , Blinking
8.
Biomed Eng Online ; 23(1): 43, 2024 Apr 23.
Article En | MEDLINE | ID: mdl-38654246

We developed a video-based tool to quantitatively assess the Glabellar Tap Reflex (GTR) in patients with idiopathic Parkinson's disease (iPD) as well as healthy age-matched participants. We also video-graphically assessed the effect of dopaminergic medication on the GTR in iPD patients, as well as the frequency and blinking duration of reflex and non-reflex blinks. The Glabellar Tap Reflex is a clinical sign seen in patients e.g. suffering from iPD. Reliable tools to quantify this sign are lacking. METHODS: We recorded the GTR in 11 iPD patients and 12 healthy controls (HC) with a consumer-grade camera at a framerate of at least 180 images/s. In these videos, reflex and non-reflex blinks were analyzed for blink count and blinking duration in an automated fashion. RESULTS: With our setup, the GTR can be extracted from high-framerate cameras using landmarks of the MediaPipe face algorithm. iPD patients did not habituate to the GTR; dopaminergic medication did not alter that response. iPD patients' non-reflex blinks were higher in frequency and higher in blinking duration (width at half prominence); dopaminergic medication decreased the median frequency (Before medication-HC: p < 0.001, After medication-HC: p = 0.0026) and decreased the median blinking duration (Before medication-HC: p = 0.8594, After medication-HC: p = 0.6943)-both in the direction of HC. CONCLUSION: We developed a quantitative, video-based tool to assess the GTR and other blinking-specific parameters in HC and iPD patients. Further studies could compare the video data to electromyogram (EMG) data for accuracy and comparability, as well as evaluate the specificity of the GTR in patients with other neurodegenerative disorders, in whom the GTR can also be present. SIGNIFICANCE: The video-based detection of the blinking parameters allows for unobtrusive measurement in patients, a safer and more comfortable option.


Blinking , Parkinson Disease , Video Recording , Humans , Parkinson Disease/physiopathology , Parkinson Disease/drug therapy , Male , Female , Aged , Middle Aged , Image Processing, Computer-Assisted/methods , Case-Control Studies
9.
Sci Rep ; 14(1): 9794, 2024 04 29.
Article En | MEDLINE | ID: mdl-38684721

Face perception is a major topic in vision research. Most previous research has concentrated on (holistic) spatial representations of faces, often with static faces as stimuli. However, faces are highly dynamic stimuli containing important temporal information. How sensitive humans are regarding temporal information in dynamic faces is not well understood. Studies investigating temporal information in dynamic faces usually focus on the processing of emotional expressions. However, faces also contain relevant temporal information without any strong emotional expression. To investigate cues that modulate human sensitivity to temporal order, we utilized muted dynamic neutral face videos in two experiments. We varied the orientation of the faces (upright and inverted) and the presence/absence of eye blinks as partial dynamic cues. Participants viewed short, muted, monochromic videos of models vocalizing a widely known text (National Anthem). Videos were played either forward (in the correct temporal order) or backward. Participants were asked to determine the direction of the temporal order for each video, and (at the end of the experiment) whether they had understood the speech. We found that face orientation, and the presence/absence of an eye blink affected sensitivity, criterion (bias) and reaction time: Overall, sensitivity was higher for upright compared to inverted faces, and in the condition where an eye blink was present compared to the condition without an eye blink. Reaction times were mostly faster in the conditions with higher sensitivity. A bias to report inverted faces as 'backward' observed in Experiment I, where upright and inverted faces were presented randomly interleaved within each block, was absent when presenting upright and inverted faces in different blocks in Experiment II. Language comprehension results revealed that there was higher sensitivity when understanding the speech compared to not understanding the speech in both experiments. Taken together, our results showed higher sensitivity with upright compared to inverted faces, suggesting that the perception of dynamic, task-relevant information was superior with the canonical orientation of the faces. Furthermore, partial information coming from eye blinks, in addition to mouth movements, seemed to play a significant role in dynamic face perception, both when faces were presented upright and inverted. We suggest that studying the perception of facial dynamics beyond emotional expressions will help us to better understand the mechanisms underlying the temporal integration of facial information from different -partial and holistic- sources, and that our results show how different strategies, depending on the available information, are employed by human observers when judging the temporal order of faces.


Facial Recognition , Humans , Female , Male , Facial Recognition/physiology , Adult , Young Adult , Reaction Time/physiology , Facial Expression , Blinking/physiology , Photic Stimulation/methods , Emotions/physiology , Face/physiology , Cues
10.
PLoS Comput Biol ; 20(4): e1011277, 2024 Apr.
Article En | MEDLINE | ID: mdl-38574161

According to the motor learning theory by Albus and Ito, synaptic depression at the parallel fibre to Purkinje cells synapse (pf-PC) is the main substrate responsible for learning sensorimotor contingencies under climbing fibre control. However, recent experimental evidence challenges this relatively monopolistic view of cerebellar learning. Bidirectional plasticity appears crucial for learning, in which different microzones can undergo opposite changes of synaptic strength (e.g. downbound microzones-more likely depression, upbound microzones-more likely potentiation), and multiple forms of plasticity have been identified, distributed over different cerebellar circuit synapses. Here, we have simulated classical eyeblink conditioning (CEBC) using an advanced spiking cerebellar model embedding downbound and upbound modules that are subject to multiple plasticity rules. Simulations indicate that synaptic plasticity regulates the cascade of precise spiking patterns spreading throughout the cerebellar cortex and cerebellar nuclei. CEBC was supported by plasticity at the pf-PC synapses as well as at the synapses of the molecular layer interneurons (MLIs), but only the combined switch-off of both sites of plasticity compromised learning significantly. By differentially engaging climbing fibre information and related forms of synaptic plasticity, both microzones contributed to generate a well-timed conditioned response, but it was the downbound module that played the major role in this process. The outcomes of our simulations closely align with the behavioural and electrophysiological phenotypes of mutant mice suffering from cell-specific mutations that affect processing of their PC and/or MLI synapses. Our data highlight that a synergy of bidirectional plasticity rules distributed across the cerebellum can facilitate finetuning of adaptive associative behaviours at a high spatiotemporal resolution.


Cerebellum , Computer Simulation , Conditioning, Eyelid , Models, Neurological , Neuronal Plasticity , Neuronal Plasticity/physiology , Animals , Cerebellum/physiology , Conditioning, Eyelid/physiology , Purkinje Cells/physiology , Blinking/physiology , Conditioning, Classical/physiology , Synapses/physiology , Computational Biology , Mice , Cerebellar Cortex/physiology
11.
Altern Lab Anim ; 52(3): 149-154, 2024 May.
Article En | MEDLINE | ID: mdl-38606566

In the cosmetics sector, many products such as shampoos have a probability of accidental ocular exposure during their routine use. One very specific safety parameter is the residence time of the substance on the corneal surface, as prolonged exposure may cause injury. In this study, we developed a system that simulates corneal exposure to blinking and tear flow, for comparing the corneal clearance times of viscous detergent formulations. The Ex Vivo Eye Irritation Test (EVEIT), which uses corneal explants from discarded rabbit eyes from an abattoir, was used as the basis for the new system. To simulate blinking, we developed a silicone wiping membrane to regularly move across the corneal surface, under conditions of constant addition and aspiration of fluid, to mimic tear flow. Six shampoo formulations were tested and were shown to differ widely in their corneal clearance time. Three groups could be identified according to the observed clearance times (fast, intermediate and slow); the reference shampoo had the shortest clearance time of all tested formulations. With this new system, it is now possible to investigate an important physicochemical parameter, i.e. corneal clearance time, for the consideration of ocular safety during the development of novel cosmetic formulations.


Blinking , Cornea , Animals , Rabbits , Cornea/drug effects , Blinking/drug effects , Animal Testing Alternatives/methods , Hair Preparations , Tears/drug effects
12.
Int Ophthalmol ; 44(1): 124, 2024 Mar 02.
Article En | MEDLINE | ID: mdl-38430354

PURPOSE: Euthyroid Graves' ophthalmology (EGO) refers to the subgroup of thyroid eye disease patients with distinct clinical presentations. This study evaluated the ocular surface and meibomian gland changes in EGO patients. METHODS: A cross-sectional study was conducted at The Chinese University of Hong Kong including 34 EGO patients and 34 age-and sex- matched healthy controls. Outcome measures include anterior segment examination, keratographic and meibographic imaging. RESULTS: Between 34 EGO patients and 34 age and sex-matched healthy controls, EGO was associated with a higher ocular surface disease index (P < 0.01), higher severity of meibomian gland dropout (upper: P < 0.001, lower: P < 0.00001) and higher percentage of partial blinking (P = 0.0036). The worse affected eyes of the EGO patients were associated with corneal staining (P = 0.0019), eyelid telangiectasia (P = 0.0009), eyelid thickening (P = 0.0013), eyelid irregularity (P = 0.0054), meibomian gland plugging (P < 0.00001), expressibility (P < 0.00001), and meibum quality (P < 0.00001). When the two eyes of the same EGO patient were compared, the degree of meibomian gland dropout was higher among the worse affected eyes (upper: P < 0.00001, and lower: P < 0.00001). Tear meniscus height, lipid layer thickness, and noninvasive break-up time were comparable between the two eyes of EGO patients and also between EGO patients and healthy controls. TMH was positively correlated with the degree of exophthalmos (r = 0.383, P < 0.05). CONCLUSION: EGO patients have more ocular surface complications and meibomian gland dropouts than healthy controls. Almost 60% of them had dry eye symptoms, but aqueous deficiency was not apparent. Further studies are warranted to clarify the mechanism of dry eye in EGO. (249 words).


Dry Eye Syndromes , Meibomian Glands , Humans , Meibomian Glands/diagnostic imaging , Cross-Sectional Studies , Dry Eye Syndromes/diagnosis , Dry Eye Syndromes/etiology , Blinking , Tears
13.
J Neurophysiol ; 131(5): 797-806, 2024 May 01.
Article En | MEDLINE | ID: mdl-38533969

Learning outcome is modified by the degree to which the subject responds and pays attention to specific stimuli. Our recent research suggests that presenting stimuli in contingency with a specific phase of the cardiorespiratory rhythm might expedite learning. Specifically, expiration-diastole (EXP-DIA) is beneficial for learning trace eyeblink conditioning (TEBC) compared with inspiration-systole (INS-SYS) in healthy young adults. The aim of this study was to investigate whether the same holds true in healthy elderly adults (n = 50, aged >70 yr). Participants were instructed to watch a silent nature film while TEBC trials were presented at either INS-SYS or EXP-DIA (separate groups). Learned responses were determined as eyeblinks occurring after the tone conditioned stimulus (CS), immediately preceding the air puff unconditioned stimulus (US). Participants were classified as learners if they made at least five conditioned responses (CRs). Brain responses to the stimuli were measured by electroencephalogram (EEG). Memory for the film and awareness of the CS-US contingency were evaluated with a questionnaire. As a result, participants showed robust brain responses to the CS, acquired CRs, and reported awareness of the CS-US relationship to a variable degree. There was no difference between the INS-SYS and EXP-DIA groups in any of the above. However, when only participants who learned were considered, those trained at EXP-DIA (n = 11) made more CRs than those trained at INS-SYS (n = 13). Thus, learned performance could be facilitated in those elderly who learned. However, training at a specific phase of cardiorespiratory rhythm did not increase the proportion of participants who learned.NEW & NOTEWORTHY We trained healthy elderly individuals in trace eyeblink conditioning, either at inspiration-systole or at expiration-diastole. Those who learned exhibited more conditioned responses when trained at expiration-diastole rather than inspiration-systole. However, there was no difference between the experimental groups in the proportion of individuals who learned or did not learn.


Conditioning, Eyelid , Humans , Male , Aged , Female , Conditioning, Eyelid/physiology , Electroencephalography , Aged, 80 and over , Heart Rate/physiology , Blinking/physiology , Conditioning, Classical/physiology
14.
IEEE Trans Vis Comput Graph ; 30(5): 2077-2086, 2024 May.
Article En | MEDLINE | ID: mdl-38437077

Eye tracking has shown great promise in many scientific fields and daily applications, ranging from the early detection of mental health disorders to foveated rendering in virtual reality (VR). These applications all call for a robust system for high-frequency near-eye movement sensing and analysis in high precision, which cannot be guaranteed by the existing eye tracking solutions with CCD/CMOS cameras. To bridge the gap, in this paper, we propose Swift-Eye, an offline precise and robust pupil estimation and tracking framework to support high-frequency near-eye movement analysis, especially when the pupil region is partially occluded. Swift-Eye is built upon the emerging event cameras to capture the high-speed movement of eyes in high temporal resolution. Then, a series of bespoke components are designed to generate high-quality near-eye movement video at a high frame rate over kilohertz and deal with the occlusion over the pupil caused by involuntary eye blinks. According to our extensive evaluations on EV-Eye, a large-scale public dataset for eye tracking using event cameras, Swift-Eye shows high robustness against significant occlusion. It can improve the IoU and F1-score of the pupil estimation by 20% and 12.5% respectively, compared with the second-best competing approach, when over 80% of the pupil region is occluded by the eyelid. Lastly, it provides continuous and smooth traces of pupils in extremely high temporal resolution and can support high-frequency eye movement analysis and a number of potential applications, such as mental health diagnosis, behaviour-brain association, etc. The implementation details and source codes can be found at https://github.com/ztysdu/Swift-Eye.


Algorithms , Eye Movements , Computer Graphics , Blinking , Pupil
15.
PLoS One ; 19(3): e0294888, 2024.
Article En | MEDLINE | ID: mdl-38457390

Dopamine is a versatile neurotransmitter with implications in many domains, including anxiety and effortful control. Where high levels of effortful control are often regarded as adaptive, other work suggests that high levels of effortful control may be a risk factor for anxiety. Dopamine signaling may be key in understanding these relations. Eye blink rate is a non-invasive proxy metric of midbrain dopamine activity. However, much work with eye blink rate has been constrained to screen-based tasks which lack in ecological validity. We tested whether changes in eye blink rate during a naturalistic effortful control task differ as a function of parent-reported effortful control and internalizing behaviors. Children played a Jenga-like game with an experimenter, but for each trial the experimenter took an increasingly long time to take their turn. Blinks-per-second were computed during each wait period. Multilevel modeling examined the relation between duration of wait period, effortful control, and internalizing behaviors on eye blink rate. We found a significant 3-way interaction between effortful control, internalizing behaviors, and duration of the wait period. Probing this interaction revealed that for children with low reported internalizing behaviors (-1 SD) and high reported effortful control (+1 SD), eye blink rate significantly decreased as they waited longer to take their turn. These findings index task-related changes in midbrain dopamine activity in relation to naturalistic task demands, and that these changes may vary as a function of individual differences in effortful control and internalizing behaviors. We discuss possible top-down mechanisms that may underlie these differences.


Dopamine , Waiting Lists , Child , Humans , Blinking , Anxiety Disorders , Anxiety
16.
Clin Neurophysiol ; 161: 17-26, 2024 May.
Article En | MEDLINE | ID: mdl-38432185

OBJECTIVE: Both blinking and walking are altered in Parkinson's disease and both motor outputs have been shown to be linked in healthy subjects. Additionally, studies suggest an involvement of basal ganglia activity and striatal dopamine in blink generation. We investigated the role of the basal ganglia circuitry on spontaneous blinking and if this role is dependent on movement state and striatal dopamine. METHODS: We analysed subthalamic nucleus (STN) activity in seven chronically implanted patients for deep brain stimulation (DBS) with respect to blinks and movement state (resting state and unperturbed walking). Neurophysiological recordings were combined with individual molecular brain imaging assessing the dopamine reuptake transporter (DAT) density for the left and right striatum separately. RESULTS: We found a significantly higher blink rate during walking compared to resting. The blink rate during walking positively correlated with the DAT density of the left caudate nucleus. During walking only, spontaneous blinking was followed by an increase in the right STN beta power and a bilateral subthalamic phase reset in the low frequencies. The right STN blink-related beta power modulation correlated negatively with the DAT density of the contralateral putamen. The left STN blink-related beta power correlated with the DAT density of the putamen in the less dopamine-depleted hemisphere. Both correlations were specific to the walking condition and to beta power following a blink. CONCLUSION: Our findings show that spontaneous blinking is related to striatal dopamine and has a frequency specific deployment in the STN. This correlation depends on the current movement state such as walking. SIGNIFICANCE: This work indicates that subcortical activity following a motor event as well as the relationship between dopamine and motor events can be dependent on the motor state. Accordingly, disease related changes in brain activity should be assessed during natural movement.


Beta Rhythm , Blinking , Deep Brain Stimulation , Parkinson Disease , Subthalamic Nucleus , Walking , Humans , Subthalamic Nucleus/physiopathology , Parkinson Disease/physiopathology , Parkinson Disease/therapy , Male , Middle Aged , Walking/physiology , Female , Blinking/physiology , Aged , Beta Rhythm/physiology , Dopamine Plasma Membrane Transport Proteins/metabolism
17.
Clin Neurophysiol ; 161: 59-68, 2024 May.
Article En | MEDLINE | ID: mdl-38447495

Blinking is a motor act characterized by the sequential closing and opening of the eyelids, which is achieved through the reciprocal activation of the orbicularis oculi and levator palpebrae superioris muscles. This stereotyped movement can be triggered reflexively, occur spontaneously, or voluntarily initiated. During each type of blinking, the neural control of the antagonistic interaction between the orbicularis oculi and levator palpebrae superioris muscles is governed by partially overlapping circuits distributed across cortical, subcortical, and brainstem structures. This paper provides a comprehensive overview of the anatomical and physiological foundations underlying the neural control of blinking. We describe the infra-nuclear apparatus, as well as the supra-nuclear control mechanisms, i.e., how cortical, subcortical, and brainstem structures regulate and coordinate the different types of blinking.


Blinking , Humans , Blinking/physiology , Animals , Brain Stem/physiology , Eyelids/physiology
18.
J Neural Eng ; 21(2)2024 Apr 02.
Article En | MEDLINE | ID: mdl-38507808

Facial paralysis is the inability to move facial muscles thereby impairing the ability to blink and make facial expressions. Depending on the localization of the nerve malfunction it is subcategorised into central or peripheral and is usually unilateral. This leads to health deficits stemming from corneal dryness and social ostracization.Objective: Electrical stimulation shows promise as a method through which to restore the blink function and as a result improve eye health. However, it is unknown whether a real-time, myoelectrically controlled, neurostimulating device can be used as assistance to this pathological condition.Approach: We developed NEURO-BLINK, a wearable robotic system, that can detect the volitional healthy contralateral blink through electromyography and electrically stimulate the impaired subcutaneous facial nerve and orbicularis oculi muscle to compensate for lost blink function. Alongside the system, we developed a method to evaluate optimal electrode placement through the relationship between blink amplitude and injected charge.Main results: Ten patients with unilateral facial palsy were enrolled in the NEURO-BLINK study, with eight completing testing under two conditions. (1) where the stimulation was cued with an auditory signal (i.e. paced controlled) and (2) synchronized with the natural blink (i.e. myoelectrically controlled). In both scenarios, overall eye closure (distance between eyelids) and cornea coverage measured with high FPS video were found to significantly improve when measured in real-time, while no significant clinical changes were found immediately after use.Significance: This work takes steps towards the development of a portable medical device for blink restoration and facial stimulation which has the potential to improve long-term ocular health.


Facial Paralysis , Humans , Bionics , Blinking , Eyelids/innervation , Facial Nerve
19.
Curr Biol ; 34(5): R191-R192, 2024 03 11.
Article En | MEDLINE | ID: mdl-38471444

Blinking is a behavior unique to animal taxa with motile eyelids, such as most amphibians and reptiles as well as all birds and mammals1. Eyelid movement has physiological functions, such as lubricating the cornea and washing away dust, but its potential signaling functions are not well understood1,2. The use of eyeblinks as a social signal is currently thought to be restricted to some primates, especially humans and their companion animals, but has not been verified in other taxa1,3,4. Here, through field observation and experiments, we demonstrate that female concave-eared torrent frogs (Odorrana tormota), which inhabit noisy streams, use eyeblinks to communicate with males to urge them to initiate amplexus for mating. Our findings reveal that eyeblinks may serve as a social signal in non-primate species.


Anura , Blinking , Animals , Male , Female , Humans , Anura/physiology , Ranidae/physiology , Noise , Mammals
20.
Ophthalmic Physiol Opt ; 44(4): 704-717, 2024 Jun.
Article En | MEDLINE | ID: mdl-38546401

PURPOSE: To investigate differences in key clinical parameters between asymptomatic and highly symptomatic soft contact lens (CL) wearers after 14 h of wear. METHODS: In this pilot investigation, Phase 1 identified asymptomatic (CLDEQ-8 score ≤ 7) and highly symptomatic (CLDEQ-8 score ≥ 20) subjects after fitting with nelfilcon A CLs. Phase 2 investigated the following over a single nelfilcon A CL-wearing day (14 ± 2 h): blinking characteristics, tear meniscus height (TMH), non-invasive tear break-up time (NIBUT), tear film osmolarity and eyelid margin staining. Parameters for the two groups were compared using linear mixed models and post-hoc testing. The relationship between comfort scores and the clinical parameters was also investigated. RESULTS: Overall, 161 and 42 subjects were enrolled into Phase 1 and 2, respectively. Twenty-five asymptomatic and 17 symptomatic subjects completed Phase 2. Lower eyelid TMH was decreased after 14 h in symptomatic compared with asymptomatic subjects (least square mean [LSM] difference -0.04 mm, 95% CI: -0.07, -0.01). Osmolarity was lower in symptomatic than in asymptomatic subjects at fitting (LSM difference -9.89, 95% CI: -18.91, -0.86). Upper eyelid margin staining was greater after 14 h in symptomatic than in asymptomatic subjects (LSM difference 0.53, 95% CI: 0.01, 1.05) and greater after 14 h than baseline in the symptomatic group (LSM difference 0.61, 95% CI: 0.16, 1.07). There was a significant relationship between comfort and upper eyelid margin staining (r = -0.40, 95% CI: -0.63, -0.11) and blink rate (r = -0.31, 95% CI: -0.57, -0.003). CONCLUSION: The potential parameters most effective in differentiating asymptomatic from symptomatic wearers were upper eyelid margin staining and lower TMH. The parameter with the strongest relationship to comfort was upper eyelid margin staining, where higher comfort scores were associated with lower levels of staining.


Blinking , Contact Lenses, Hydrophilic , Tears , Humans , Contact Lenses, Hydrophilic/adverse effects , Male , Female , Adult , Tears/metabolism , Tears/physiology , Pilot Projects , Blinking/physiology , Young Adult , Osmolar Concentration , Dry Eye Syndromes/diagnosis , Dry Eye Syndromes/etiology , Dry Eye Syndromes/physiopathology , Eyelids
...