Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 633
Filtrar
1.
Am J Vet Res ; 85(7)2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38848749

RESUMEN

OBJECTIVE: To assess the fatigue and load-to-failure mechanical characteristics of an intramedullary nail with a threaded interference design (TID) in comparison to a commercially available veterinary angle-stable nail with a Morse taper bolt design (I-Loc) of an equivalent size. METHODS: 10 single interlocking screw/bolt constructs of TID and I-Loc implants were assembled using steel pipe segments and placed through 50,000 cycles of simulated, physiologic axial or torsional loading. Entry torque, postfatigue extraction torque, and 10th, 25,000th, and 50,000th cycle torsional toggle were assessed. Each construct was then loaded to failure in the same respective direction as fatigue testing. Four complete constructs of each design were then assessed using a synthetic bone analog with a 50-mm central defect via nondestructive torsional and axial loading followed by axial load to failure. RESULTS: All constructs were angle stable at all time points and withstood fatigue loading. Median insertional torque, extraction torque-to-insertion torque ratio, and torsional yield load were 33%, 33%, and 72.5% lower, respectively, for the TID interlocking screws. No differences in torsional peak load, torsional stiffness, axial yield load, axial stiffness, or axial peak load were identified. No differences in complete construct angle stability, torsional stiffness, axial peak load, axial stiffness, or axial yield load were identified. CLINICAL RELEVANCE: The TID had an inferior torsional yield load when compared to I-Loc implants but generated angle stability and sustained simulated physiologic fatigue loading. The TID may be a suitable mechanism for generating angle stability in interlocking nails.


Asunto(s)
Clavos Ortopédicos , Fijación Intramedular de Fracturas , Torque , Clavos Ortopédicos/veterinaria , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/veterinaria , Fenómenos Biomecánicos , Ensayo de Materiales , Animales , Tornillos Óseos/veterinaria
2.
Vet Comp Orthop Traumatol ; 37(4): 163-172, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38698626

RESUMEN

OBJECTIVES: The first objective of this study was to compare the mechanical performance of a straight and contoured rod for the sliding on pivot-locking clamp (SOP-LC) system. The second objective was to compare single-cycle bending and torsion of the SOP-LC rod-bone constructs to a bone gap model between two clamp configurations. STUDY DESIGN: First experiment, 5 mm diameter rods from the 3.5 mm SOP-LC system, 4 straight and 4 bent rods were mechanically compared in four-point bending. The second experiment, 8 constructs with clamps on a single side of the rod and 8 constructs with clamps on alternating sides were compared in four-point bending and torsion. A torque limiting screwdriver at 2.5N was used for all constructs. RESULTS: There were not significant differences between the noncontoured versus contoured rods. Constructs with clamps on a single side had a significantly higher yield load, yield displacement and bending strength, but the constructs with alternating clamps had a significantly higher initial torsional stiffness. There were no other significant differences. Mild clamp slippage and mild screw bending were noted in all the torsion tested constructs graphically with multiple stiffness slopes and visually on the post-tested constructs. CONCLUSION: Torque applied to initial screw placement may play a role in reducing clamp slippage. Although bending yield load, bending yield displacement, bending strength and torsional stiffness were improved by different clamp placement, clinically this will depend on fracture type. Further studies are needed for clinical significance.


Asunto(s)
Pruebas Mecánicas , Animales , Fenómenos Biomecánicos , Pruebas Mecánicas/métodos , Pruebas Mecánicas/instrumentación , Fracturas Óseas/cirugía , Fracturas Óseas/veterinaria , Ensayo de Materiales/métodos , Tornillos Óseos/veterinaria
3.
Open Vet J ; 14(3): 885-894, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38682140

RESUMEN

Background: The study employs finite element analysis to investigate stress distribution in the radius of toy poodles after screw removal. The examination focuses on the biomechanical implications of varied screw hole configurations using 1.5 and 2.0-mm locking compression plates (LCPs) with notched head T-Plates. Aim: To provide a noninvasive approach to analyzing the immediate consequences of screw removal from the radius bone in toy poodles. Specifically, it explores the impact of varied plate designs and screw arrangements on stress distribution within the forelimb bones. Methods: The study constructs a three-dimensional bone model of the toy poodle's forelimb based on computed tomography (CT) images. Simulations were designed to replicate jumping and landing from a 40 cm height, comparing stress distribution in the radius post-screw removal. Results: The analysis reveals significant variations in stress distribution patterns between the two LCPs. The radius implanted with the 2.0-mm LCP displays a uniform stress distribution, contrasting with the 1.5-mm plates. Localized stress concentration is observed around the screw holes, while trabecular bone regions near the screw holes exhibit lower stress levels. Conclusion: The study highlights the plate designs and screw configurations that affect bone stress in toy poodle forelimbs post-screw removal. The findings provide valuable insights for veterinarians, aiding informed decisions in veterinary orthopedic practices.


Asunto(s)
Placas Óseas , Tornillos Óseos , Análisis de Elementos Finitos , Animales , Tornillos Óseos/veterinaria , Tornillos Óseos/efectos adversos , Placas Óseas/veterinaria , Fenómenos Biomecánicos , Estrés Mecánico , Radio (Anatomía)/cirugía , Miembro Anterior , Tomografía Computarizada por Rayos X/veterinaria
4.
J Small Anim Pract ; 65(6): 409-412, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38459788

RESUMEN

This report describes a centralisation procedure for the treatment of a radial non-union, characterised by extensive bone loss and an intact ulna, in an 18-month-old toy poodle. A lateral approach to the radius/ulna shafts was realised and, after debridement of the non-union site, an ulnar osteotomy was performed proximal to the styloid process of the ulna. Transposition of the distal fragment of the radius to the distal end of the osteotomised proximal segment of the ulna was performed and the stabilisation was obtained using a locking plate with proximal screws in the ulnar shaft and distal screws in the radius epiphysis. The patient achieved bone union in 10 weeks and the last evaluation, performed 112 weeks postoperatively, showed a full return to pre-injury function. Based on the results of this report, the centralisation was effective in the treatment of post-traumatic absence of the radial shaft in a dog.


Asunto(s)
Osteotomía , Radio (Anatomía) , Perros/lesiones , Animales , Radio (Anatomía)/cirugía , Radio (Anatomía)/lesiones , Osteotomía/veterinaria , Osteotomía/métodos , Cúbito/cirugía , Placas Óseas/veterinaria , Masculino , Tornillos Óseos/veterinaria , Resultado del Tratamiento , Enfermedades de los Perros/cirugía , Fijación Interna de Fracturas/veterinaria , Fijación Interna de Fracturas/métodos , Fracturas del Radio/veterinaria , Fracturas del Radio/cirugía
5.
Vet Surg ; 53(3): 447-459, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38380523

RESUMEN

OBJECTIVE: To determine the influence of screw configuration on the reduction and stabilization of simulated complete lateral condylar fracture. STUDY DESIGN: Randomized experimental crossover study. METHODS: A lateral condylar fracture was simulated in 18 cadaver limbs from nine horses. Each limb underwent repair with 4.5 mm diameter cortex screws, tightened to 4 Nm, in a linear and triangular configuration. Computed tomography (CT) of each repair was performed with the limbs in unloaded and loaded conditions. Fracture gaps were measured at the dorsal, palmar, and middle locations of the third metacarpal condyle. Fracture gap measurements were graded 0-4, based on voxels. Following descriptive analysis, a Bayesian network (BN) model was fitted to the data. RESULTS: The median fracture grade was 0 (range: 0-4) for unloaded linear repairs and 2 (0-4) for loaded linear repairs. The median fracture grade was 0 (0-3) for unloaded triangular repairs and 1 (0-3) for loaded triangular repairs. Bayesian network sensitivity analysis showed that the construct configuration reduced the uncertainty in the measured fracture outcome by 0.8%. CONCLUSION: Triangular screw configuration resulted in better fracture reduction and stability in comparison with linear screw configuration. However, the BN sensitivity analysis results showed that the effect of construct configuration on fracture outcome was weak. CLINICAL SIGNIFICANCE: These findings indicate a low probability that triangular repair of lateral condylar fracture will result in improved outcomes, when compared with linear repair.


Asunto(s)
Fracturas Óseas , Enfermedades de los Caballos , Huesos Metatarsianos , Caballos , Animales , Teorema de Bayes , Estudios Cruzados , Fracturas Óseas/veterinaria , Tornillos Óseos/veterinaria , Extremidad Superior , Fenómenos Biomecánicos , Huesos Metatarsianos/cirugía , Fijación Interna de Fracturas/veterinaria
6.
Vet Comp Orthop Traumatol ; 37(4): 173-180, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38331034

RESUMEN

OBJECTIVE: The aim of this study was to compare stiffness and strain of an in vitro fracture-gap model secured with a primary 3.5-mm locking compression plate (LCP) at three primary plate working lengths without and with an orthogonal 2.7-mm LCP. STUDY DESIGN: Primary plate screw configurations modeled short working length (SWL), medium working length (MWL), and long working length (LWL) constructs. Construct stiffness with and without an orthogonal plate during nondestructive four-point bending and torsion, and plate surface strain measured during bending, was analyzed. RESULTS: Single plate construct stiffness was significantly, incrementally, lower in four-point bending and torsion as working length was extended. Addition of an orthogonal plate resulted in significantly higher bending stiffness for SWL, MWL, and LWL (p < 0.05) and torsional stiffness for MWL and LWL (p < 0.05). Single plate construct strain was significantly, incrementally, higher as working length was extended. Addition of an orthogonal plate significantly lowered strain for SWL, MWL, and LWL constructs (p < 0.01). CONCLUSION: Orthogonal plate application resulted in higher bending and torsional construct stiffness and lower strain over the primary plate in bending in this in vitro model. Working length had an inverse relationship with construct stiffness in bending and torsion and a direct relationship with strain. The inverse effect of working length on construct stiffness was completely mitigated by the application of an orthogonal plate in bending and modified in torsion.


Asunto(s)
Placas Óseas , Placas Óseas/veterinaria , Animales , Fenómenos Biomecánicos , Fracturas Óseas/cirugía , Fracturas Óseas/veterinaria , Ensayo de Materiales , Fijación Interna de Fracturas/veterinaria , Fijación Interna de Fracturas/instrumentación , Estrés Mecánico , Tornillos Óseos/veterinaria
7.
Vet Surg ; 53(4): 603-612, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38240128

RESUMEN

OBJECTIVE: To describe fluoroscopically-assisted closed reduction and percutaneous fixation of sacroiliac-luxation (SIL) in cats and report radiographic results and long-term functional outcomes. STUDY DESIGN: Retrospective clinical study. ANIMALS: Eleven cats. METHODS: Percutaneous fixation of 17 SILs in 11 cats was performed with 2.4 mm headless cannulated compression screws under fluoroscopic guidance. Luxation-reduction, screw placement and purchase within the sacral body, pelvic canal diameter ratio (PCDR) and hemipelvic canal width ratio (HCWR) were assessed on pre- and postoperative radiographs. Radiographic follow-up was performed to assess the same parameters when available. Long-term clinical outcome was evaluated with an owner questionnaire. Wilcoxon paired-test was performed for comparison. RESULTS: Mean age and bodyweight of the cats were 3.3 ± 2.6 years and 4.0 ± 0.82 kg, respectively. Nine cats presented with concurrent pelvic injuries. Median luxation-reduction was 94.1% (IQR = 13.9) and median screw-purchase within the sacral body was 73.3% (IQR = 17.0) immediately postoperatively. One screw exited the sacral body caudally. Upon 7-week radiographic follow-up, luxation-reduction (88.3%, IQR = 20.1) and screw-purchase (70.7%, IQR = 12.8) had decreased compared to immediately postoperatively (p = .008 and p = .013 respectively). Screw migration was not observed. PCDR and HCWR measured on postoperative radiographs indicated successful restoration of the pelvic canal width. Owners reported an excellent long-term functional outcome (mean postoperative time: 19 ± 5 months). CONCLUSION: Fluoroscopically-assisted closed reduction and fixation of feline SIL using 2.4 mm headless cannulated compression screws allowed good reduction and optimal screw purchase within the sacral body. An excellent functional outcome was reported. CLINICAL SIGNIFICANCE: Minimally invasive reduction and fixation with headless compression screws should be considered in cats with SIL.


Asunto(s)
Tornillos Óseos , Luxaciones Articulares , Articulación Sacroiliaca , Animales , Gatos , Tornillos Óseos/veterinaria , Estudios Retrospectivos , Masculino , Femenino , Fluoroscopía/veterinaria , Articulación Sacroiliaca/cirugía , Articulación Sacroiliaca/lesiones , Luxaciones Articulares/veterinaria , Luxaciones Articulares/cirugía , Resultado del Tratamiento , Fijación Interna de Fracturas/veterinaria , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación
8.
Vet Comp Orthop Traumatol ; 37(4): 206-212, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38190989

RESUMEN

OBJECTIVE: The aim of this study was to report postoperative complications and long-term outcomes following transcondylar screw placement for humeral intracondylar fissure (HIF). STUDY DESIGN: It was a retrospective single-centre case series. Medical records (2018-2022) were reviewed for dogs with HIF treated with transcondylar screw placement. Data collected included signalment, concurrent orthopaedic disease, partial or complete HIF, surgeon, surgical approach, surgical technique and implant type, transcondylar screw angulation, postoperative complications and outcomes. Long-term outcome was assessed with owner questionnaire, orthopaedic examination and follow-up radiography. Statistical analysis was performed to identify risk factors predisposing to a complication or a poor outcome. RESULTS: Forty-seven dogs (57 elbows) met the inclusion criteria; long-term follow-up was available in 41 dogs (50 elbows). Minor and major medical complications were noted in seven and three elbows respectively. The total complication rate was 17.5%. Increasing age was significantly associated with a reduced risk of postoperative complications (p = 0.0051). No other risk factors were identified. A postoperative complication was not associated with a less than full outcome (p = 0.5698). CONCLUSION: Transcondylar screw placement for HIF is associated with a low complication rate and good outcome.


Asunto(s)
Tornillos Óseos , Complicaciones Posoperatorias , Animales , Perros/cirugía , Estudios Retrospectivos , Masculino , Tornillos Óseos/veterinaria , Femenino , Complicaciones Posoperatorias/veterinaria , Complicaciones Posoperatorias/etiología , Resultado del Tratamiento , Enfermedades de los Perros/cirugía , Húmero/cirugía , Fijación Interna de Fracturas/veterinaria , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/efectos adversos , Fracturas del Húmero/cirugía , Fracturas del Húmero/veterinaria
9.
Vet Surg ; 53(2): 264-276, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37435744

RESUMEN

OBJECTIVE: To determine the influence of screw direction on complications following transcondylar screw placement for the treatment of canine humeral intracondylar fissures (HIFs). STUDY DESIGN: Equivalence, parallel group, randomized clinical trial. SAMPLE POPULATION: Fifty-two client owned dogs (73 elbows). METHODS: Transcondylar screw placement was randomized to either a medial or lateral approach. The primary outcome was the incidence of postoperative complications. RESULTS: There were 37 cases in the lateral approach group and 36 cases in the medial approach group. There was a significantly greater proportion of postoperative complications following placement of transcondylar screws from a lateral to medial direction (p = .001). There were seven cases with complications (19%) in the medial approach group versus 23 cases with complications (62%) in the lateral approach group. The majority of complications were seromas (n = 13) and surgical site infections (n = 16) with 4 complications requiring further surgery. Implant area moment of inertia (AMI), normalized to bodyweight, was lower in dogs with a major complication (p = .037). CONCLUSION: Transcondylar screws placed from lateral to medial for canine HIFs had a greater proportion of postoperative complications in this randomized clinical trial design. Implants with a lower AMI, relative to bodyweight, were more likely to lead to major complications. CLINICAL SIGNIFICANCE: We recommend placing transcondylar screws from medial to lateral for canine HIFs to reduce the risk of postoperative complications. Relatively small diameter implants had an increased risk of major complications.


Asunto(s)
Enfermedades de los Perros , Fijación Interna de Fracturas , Húmero , Animales , Perros , Tornillos Óseos/veterinaria , Enfermedades de los Perros/cirugía , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/veterinaria , Húmero/cirugía , Estudios Retrospectivos , Infección de la Herida Quirúrgica/prevención & control , Infección de la Herida Quirúrgica/veterinaria
10.
Vet Comp Orthop Traumatol ; 37(1): 13-22, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37562428

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the feasibility of safe positioning of double 2.3-mm headless cannulated self-compression screws (HCS) in a small dog cadaveric sacroiliac luxation model and to compare the static rotational biomechanical properties of fixation repaired using two different screw systems with a minimally invasive osteosynthesis technique: double 2.3-mm HCS and a single 3.5-mm standard cortical screw placed in a lag fashion. STUDY DESIGN: A unilateral small dog sacroiliac luxation model was stabilized using double 2.3-mm HCS (n = 11) or a single 3.5-mm cortical screw (n = 11). Radiographic and computed tomography (CT) imaging analyses and biomechanical testing of rotational force on the sacroiliac joint of both fixations were performed. The maximum load at failure and failure modes of each fixation were recorded and compared. RESULTS: Fluoroscopically guided percutaneous application of double HCS was safe in a unilateral sacroiliac luxation model in small dogs without violation of the vertebral and ventral sacral foramen. Furthermore, resistance to rotational force applied on fixation of the sacroiliac joint repaired with double 2.3-mm HCS estimated by maximum failure load was significantly higher than that of a single 3.5-mm cortical screw (p < 0.001). CONCLUSION: Although this was an experimental cadaveric study, based on our results, the use of smaller double HCS may be beneficial as an alternative to the conventional single lag screw for stabilization of sacroiliac luxation in small dogs.


Asunto(s)
Enfermedades de los Perros , Luxaciones Articulares , Humanos , Perros , Animales , Tornillos Óseos/veterinaria , Luxaciones Articulares/cirugía , Luxaciones Articulares/veterinaria , Fijación Interna de Fracturas/veterinaria , Articulación Sacroiliaca/cirugía , Cadáver , Fenómenos Biomecánicos
11.
Vet Surg ; 53(2): 330-340, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37280742

RESUMEN

OBJECTIVE: To describe an arthroscopically guided technique for lag screw placement across subchondral bone cyst (SBC) in the medial femoral condyle (MFC) and to compare postoperative racing performance with corticosteroid injection and cyst debridement. STUDY DESIGN: Retrospective cohort study. ANIMALS: One hundred twenty-three horses with 134 MFC SBCs undergoing treatment at a single referral hospital in the UK between January, 2009, and December, 2020. METHODS: Sex, age, limb affected, radiographic cyst dimensions, preoperative and postoperative lameness, surgical technique (lag screw placement, cyst debridement, intralesional corticosteroid injection), and, where applicable, screw positioning were recorded retrospectively. A ratio was calculated using measurements from preoperative and postoperative radiographs. Outcome was assessed by resolution or improvement in lameness, reduction in cyst size, and starting one race after treatment. Outcome data was compared between treatment groups. RESULTS: Twenty-six of 45 (57.8%) horses that underwent transcondylar screw placement raced postoperatively, at a median of 403 days between surgery and first postoperative race. There was no difference between treatment groups with regard to racing or preoperative and postoperative lameness. Cysts treated with transcondylar screw placement had a greater reduction in cyst size and a reduced period of convalescence in comparison with those that underwent debridement; the results were similar to those treated by intralesional corticosteroid injection. CONCLUSION: Postoperative racing rates were similar for all techniques. Convalescence was reduced for lag screw placement and corticosteroid injection compared to debridement. CLINICAL SIGNIFICANCE: The arthroscopically guided technique results in radiographically consistent screw placement and cyst engagement and offers a viable alternative to other treatments.


Asunto(s)
Quistes Óseos , Enfermedades de los Caballos , Humanos , Caballos , Animales , Estudios Retrospectivos , Convalecencia , Cojera Animal , Fémur/cirugía , Quistes Óseos/cirugía , Quistes Óseos/veterinaria , Tornillos Óseos/veterinaria , Enfermedades de los Caballos/cirugía , Corticoesteroides
12.
N Z Vet J ; 72(1): 17-27, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37772312

RESUMEN

AIM: To biomechanically compare the bending stiffness, strength, and cyclic fatigue of titanium additively manufactured (AM) and conventionally manufactured (CM) limited contact plates (LCP) of equivalent dimensions using plate-screw constructs. METHODS: Twenty-four 1.5/2.0-mm plate constructs (CM: n = 12; AM: n = 12) were placed under 4-point bending conditions. Data were collected during quasi-static single cycle to failure and cyclic fatigue testing until implants plastically deformed or failed. Bending stiffness, bending structural stiffness, and bending strength were determined from load-displacement curves. Fatigue life was determined as number of cycles to failure. Median test variables for each method were compared using the Wilcoxon rank sum test within each group. Fatigue data was also analysed by the Kaplan-Meier estimator of survival function. RESULTS: There was no evidence for a difference in bending stiffness and bending structural stiffness between AM and CM constructs. However, AM constructs exhibited greater bending strength (median 3.07 (min 3.0, max 3.4) Nm) under quasi-static 4-point bending than the CM constructs (median 2.57 (min 2.5, max 2.6) Nm, p = 0.006). Number of cycles to failure under dynamic 4-point bending was higher for the CM constructs (median 164,272 (min 73,557, max 250,000) cycles) than the AM constructs (median 18,704 (min 14,427, max 33,228) cycles; p = 0.02). Survival analysis showed that 50% of AM plates failed by 18,842 cycles, while 50% CM plates failed by 78,543 cycles. CONCLUSION AND CLINICAL RELEVANCE: Additively manufactured titanium implants, printed to replicate a conventional titanium orthopaedic plate, were more prone to failure in a shorter fatigue period despite being stronger in single cycle to failure. Patient-specific implants made using this process may be brittle and therefore not comparable to CM orthopaedic implants. Careful selection of their use on a case/patient-specific basis is recommended.


Asunto(s)
Aleaciones , Titanio , Animales , Placas Óseas/veterinaria , Tornillos Óseos/veterinaria , Fenómenos Biomecánicos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/veterinaria
13.
Vet Surg ; 52(7): 983-993, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37551960

RESUMEN

OBJECTIVE: To report a surgical technique and outcomes of transiliosacral toggle suture repair to treat feline bilateral sacroiliac luxation/fracture (SILF). STUDY DESIGN: Retrospective study. ANIMALS: Fifteen client-owned cats. METHODS: The medical records of cats with bilateral SILF treated using a transiliosacral toggle suture repair were reviewed. Short- and medium-term outcomes were assessed through standard postoperative clinical evaluation and radiographs, including measurements of angle of deviation (AoD), percentage of reduction (PoR), and pelvic canal width ratio (PCWR). Long-term functional follow up was obtained from a questionnaire derived from the Feline Musculoskeletal Pain Index (FMPI). RESULTS: Fifteen cats were enrolled retrospectively, among which 13 survived to discharge. One minor wound complication, treated by secondary intention healing, was encountered. No major complication was reported. Immediately postoperatively, the mean absolute PoR values were 88.1 ± 11.2% and 91 ± 11.6% on the right and left side, respectively. The mean absolute AoD was 3.1 ± 2.8°, and the mean PCWR was 1.24 ± 0.08. The medium-term radiographic follow up at a median of 205 (71-682) days postsurgery revealed the good stability of the repair. Excellent functional outcomes were identified upon the analysis of 12 long-term questionnaires at a median of 365 (119-798) days postsurgery. CONCLUSION: Anatomic reduction was satisfactory and comparable with previously described techniques with good implant placement documented. Functional outcomes based on FMPI-derived questionnaires were good to excellent in our population. CLINICAL SIGNIFICANCE: Transiliosacral toggle suture stabilization of bilateral SILF was associated with good outcomes in cats. Further studies are required to compare biomechanical properties and outcomes between this technique and previously described transiliosacral stabilization.


Asunto(s)
Enfermedades de los Gatos , Fracturas Óseas , Luxaciones Articulares , Humanos , Gatos/cirugía , Animales , Estudios Retrospectivos , Tornillos Óseos/veterinaria , Articulación Sacroiliaca , Luxaciones Articulares/veterinaria , Fracturas Óseas/veterinaria , Suturas , Resultado del Tratamiento , Enfermedades de los Gatos/cirugía
14.
Am J Vet Res ; 84(9)2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37406998

RESUMEN

OBJECTIVE: To evaluate the ease and accuracy of using a 3-D printed (3-DP) drill guide to insert Kirschner wires through the ilium and into the sacral body in preparation for minimally invasive iliosacral screw placement in dog cadavers. ANIMALS: 10 dog cadavers weighing 20 to 30 kg (mean ± SD, 24.5 ± 5 kg). METHODS: Kirschner wires were placed using a limited approach to the lateral ilium. Fluoroscopy was used in freehand and 3-DP drill guide application groups to facilitate the placement of a 1.0-mm Kirschner wire that was over-drilled using a 2.5-mm cannulated drill bit. Kirschner wires were placed using a 3-DP drill guide on 1 hemipelvis and freehand wire placement was done on the contralateral hemipelvis. Postprocedural CTs were obtained, and 2-D and 3-D analyses were performed. The Student t-test and Wilcoxon rank sum test were used to compare groups. A Pearson correlation coefficient was performed to evaluate the in-group correlation. RESULTS: Likert scores that assessed the ease of the procedure were significantly greater (P = .04) and the incision length was significantly shorter (P = .016) in the 3-DP drill guide group compared with the freehand group. The time of the procedure, the number of attempts to obtain accurate Kirschner wire placement, and fluoroscopy images did not differ (P > .05) between application groups. Drill tracks were primarily confined to the sacral body, with minor projected screw thread cortical breeches occurred in 1 cadaver in the freehand group and 2 cadavers in the 3-DP drill guide group. CLINICAL RELEVANCE: The 3-DP drill guide simplified appropriate iliosacral Kirschner wire placement through a smaller incision compared with freehand drilling and would appear to be an efficient, practical instrument to facilitate accurate fluoroscopic-assisted screw placement when stabilizing sacroiliac luxations in dogs.


Asunto(s)
Hilos Ortopédicos , Enfermedades de los Perros , Perros , Animales , Hilos Ortopédicos/veterinaria , Tornillos Óseos/veterinaria , Sacro/diagnóstico por imagen , Sacro/cirugía , Fluoroscopía/veterinaria , Cadáver
15.
Vet Surg ; 52(8): 1128-1139, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37302003

RESUMEN

OBJECTIVES: To compare (1) performance of compact versus standard flute drill bits, (2) screw insertion properties and (3) pullout variables between interlocking thread (ITS) and buttress thread (BTS) self-tapping screws in third metacarpi. STUDY DESIGN: In vitro experimental study. SAMPLE POPULATION: Paired third metacarpi from 11 Thoroughbreds aged 2-4 years. METHODS: Screws were inserted into the lateral condylar fossae following bone preparation using the respective drill bit for each screw type. Screw pullout was achieved using a mechanical testing system. Density and porosity of bone surrounding screw holes was measured with microcomputed tomography following each pullout test. Drilling, screw insertion and pullout variables were compared between drill bit and screw types using repeated measures ANOVA. Linear regression analyses were used to characterize relationships between bone tissue properties and drill bit and screw outcomes. RESULTS: Maximum torque power spectral density (PSD) was lower for compact flute drill bits. Insertion torque was 50% higher for ITS. BTS had 33% greater preyield stiffness and 7% greater mean yield force. Bone tissue properties affected measured variables similarly for both screw and drill bit types. CONCLUSIONS: Lower torque PSD may increase durability of the compact flute drill bit. ITS had greater insertional torque, which may reflect greater bone engagement. BTS had greater resistance to axial pullout forces. CLINICAL SIGNIFICANCE: Metacarpal bone provides a simple model for comparison of drill bit and screw designs. Use of ITS to repair equine fractures subject to predominantly tensile forces is not justified based on the results of this study.


Asunto(s)
Enfermedades de los Caballos , Huesos del Metacarpo , Animales , Caballos/cirugía , Huesos del Metacarpo/cirugía , Microtomografía por Rayos X , Fenómenos Biomecánicos , Tornillos Óseos/veterinaria , Hueso Cortical , Torque , Cadáver
16.
Open Vet J ; 13(5): 645-653, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37304606

RESUMEN

Background: Rupture of the common calcaneal tendon is the second most frequent tendon rupture in dogs and may lead to severe lameness and pain. Surgical repair consists of re-apposition of the damaged tendon ends using sutures, but this type of repair is not always possible especially if the tendon has retracted. Tendon augmentation with an ultra-high molecular weight polyethylene (UHMWPE) implant is a recent solution to support the sutures and allow the repair of the canine calcaneal tendon. However, its biomechanical fixation strength remains untested for this pathology. Aim: To evaluate the biomechanical fixation strength of a UHMWPE implant for the repair of the canine calcaneal tendon. Methods: Ex-vivo biomechanical study was carried out on eight cadaveric hindlimbs from four adult dogs. Hindlimbs were tested under two independent modalities: proximal tendinous fixation (PTF) and distal calcaneus fixation (DCF), using a testing machine. PTF was achieved by eight simple interrupted polypropylene sutures performed through the UHMWPE implant. The latter was sandwiched inside the gastrocnemius tendon, which had previously been incised over about 5 cm longitudinally, and through the tendon of the superficial digital flexor. DCF was performed using an interference screw, which locked the UHMWPE implant into a calcaneus tunnel drilled perpendicularly. Results: Yield, failure load, and linear stiffness (mean ± SD) for the DCF modality were 920 ± 139 N, 1,007 ± 146 N, and 92 ± 15.21, respectively, which were greater than for the PTF modality (663 ± 92 N, 685 ± 84 N and 25.71 ± 5.74, respectively, p < 0.05). Failure modes were different between fixation modalities: for PTF it was suture breakage (n = 7/8), while for DCF it was implant damage and slippage (n = 8/8). Conclusion: The biomechanical fixation strength of the UHMWPE implant was greater for DCF than that of PTF, and should be suitable for calcaneal tendon repair in dogs. The clinical prediction of rupture of this calcaneal tendon repair will occur at the level of the PTF.


Asunto(s)
Tendón Calcáneo , Canidae , Enfermedades de los Perros , Traumatismos de los Tendones , Perros , Animales , Tendón Calcáneo/cirugía , Traumatismos de los Tendones/cirugía , Traumatismos de los Tendones/veterinaria , Suturas/veterinaria , Tornillos Óseos/veterinaria
17.
Vet Comp Orthop Traumatol ; 36(5): 250-256, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37130556

RESUMEN

OBJECTIVE: The aim of this study was to compare the interfragmentary compressive force and area of compression generated by cortical screws inserted as either a lag screw or position screw in simulated lateral humeral condylar fractures. STUDY DESIGN: Ex vivo biomechanical study. MATERIALS AND METHODS: Thirteen pairs of cadaveric humeri from skeletally mature Merinos with simulated lateral humeral condylar fractures were used. Pressure sensitive film was inserted into the interfragmentary interface prior to fracture reduction with fragment forceps. A cortical screw was inserted as a lag screw or a position screw and tightened to 1.8Nm. Interfragmentary compression and area of compression were quantified and compared between the two treatments groups at three time points. RESULTS: After fracture reduction using fragment forceps (Time point 1: T1), there was no significant difference in interfragmentary compression and area of compression between the two treatments. A combination of fragment forceps and a cortical screw inserted as a lag screw (Time point 2: T2) produced significantly greater interfragmentary compression and area of compression compared with the same screw inserted as a positional screw. After removal of the fragment forceps, leaving only the cortical screw (Time point 3: T3), both the interfragmentary compression and area of compression remain significantly greater in the lag screw group. CONCLUSION: Lag screws generate a greater force of compression and area of compression compared with position screws in this mature ovine humeral condylar fracture model.


Asunto(s)
Fracturas del Húmero , Enfermedades de las Ovejas , Animales , Ovinos/cirugía , Fijación Interna de Fracturas/veterinaria , Tornillos Óseos/veterinaria , Fracturas del Húmero/cirugía , Fracturas del Húmero/veterinaria , Fijación de Fractura/veterinaria , Húmero , Fenómenos Biomecánicos
18.
Vet Comp Orthop Traumatol ; 36(6): 311-316, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37160257

RESUMEN

OBJECTIVE: An increased rate of surgical site infection (SSI) following treatment of canine humeral intracondylar fissure (HIF) with a lateromedially (LM) placed transcondylar screw (TCS) compared with a mediolateral (ML) TCS has been previously postulated. We hypothesized that the direction of insertion of the TCS would not affect the incidence of postoperative SSI. STUDY DESIGN: It was single-centre retrospective study. Dogs with HIF confirmed by computerized tomography, treated by TCS placement (between 2008 and 2019) and with a minimum follow-up of 12 weeks, were included. The following data were recorded: signalment, presenting clinical signs, direction of placement and size of the utilized TCS, surgical and anaesthetic times, concurrent surgical procedures, presence of concomitant elbow pathology, perioperative and postoperative antibiotic usage and postoperative complications. Recorded data were analysed with a multinomial logistic regression model with a p-value less than or equal to 0.05. RESULTS: Thirty-five dogs (46 elbows) met the inclusion criteria. Median clinical follow-up interval was 52 weeks. Seven of thirty-one elbows with a ML TCS, and 4/15 elbows with a LM TCS developed SSI. Four of nine dogs that underwent bilateral single-surgery TCS placement developed SSI unilaterally. CONCLUSION: No significant difference was shown in short-term SSI occurrence between the ML and the LM direction of placement of the TCS.


Asunto(s)
Enfermedades de los Perros , Infección de la Herida Quirúrgica , Perros , Animales , Infección de la Herida Quirúrgica/veterinaria , Estudios Retrospectivos , Incidencia , Húmero , Tornillos Óseos/veterinaria , Enfermedades de los Perros/cirugía
19.
J Equine Vet Sci ; 126: 104500, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37105415

RESUMEN

A 6-month-old thoroughbred colt foal was referred to a private equine referral hospital for evaluation of an acute onset, left hind limb lameness. On arrival the foal was 4/5 lame on the left hind at walk and there was diffuse swelling of the left hind pastern and fetlock region. The physical exam was otherwise unremarkable. Digital radiographs of the left hind pastern identified a Salter-Harris type-2 physeal fracture of the proximal phalanx. The fracture was initially treated conservatively using a cast, but the immobilization was not sufficient at achieving adequate reduction. As a result, the fracture was stabilized surgically using a construct consisting of a cortical lag screw, four locking head screws and a locking T-plate. The foal recovered uneventfully and was sound and in race training at a 2 year follow up. This case report highlights that surgical repair via internal fixation is preferable to conservative management of proximal physeal fractures of the first phalanx.


Asunto(s)
Tornillos Óseos , Fijación Interna de Fracturas , Animales , Caballos , Masculino , Fijación Interna de Fracturas/veterinaria , Tornillos Óseos/veterinaria
20.
Vet Surg ; 52(4): 538-544, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36929604

RESUMEN

OBJECTIVES: (1) To evaluate the accuracy of an aiming device on placement of humeral transcondylar screws compared to fluoroscopic methods. (2) To compare experience level on outcome. STUDY DESIGN: Randomized, match pair, prospective ex-vivo study. SAMPLE POPULATION: A total of 68 dogs. METHODS: Canine cadaveric forelimbs were randomly assigned to either aiming device or fluoroscopic-guided groups, and to diplomate or resident. Digital radiography was used to evaluate screw trajectory deviation and eccentricity on the humeral condyle. Procedure time, outcome based on experience, and complications were recorded. RESULTS: The aiming device screw trajectory angle was decreased in the right limb (1.9 ± 1.1°) compared with the left (3.6 ± 1.1°, p = .0178), and compared to fluoroscopy (3.4 ± 1.1° p = .0128). There was no difference between leg laterality with fluoroscopy (p = .9979). Trajectory angle was increased with resident versus diplomate (3.4 ± 1.1° and 2.5 ± 1.1° respectively, p = .0366). Eccentricity deviation was decreased using fluoroscopy versus aiming device (3.1 ± 0.36 mm, 4.2 ± 0.36 mm, respectively, p = .0017). The risk of joint involvement was 8 times greater in aiming device groups, though not significant (p = .0575). Significant complications included increased drill attempts in fluoroscopic groups (p = .0237). CONCLUSION: The aiming device provided accurate placement of transcondylar screws, in terms of both position on the condyle and trajectory angle. Results were similar to fluoroscopic-guided method. CLINICAL SIGNIFICANCE: An aiming device is an acceptable means of placing humeral transcondylar screws. The use of the aiming device had an eight times increased risk of joint involvement compared to fluoroscopy.


Asunto(s)
Tornillos Óseos , Fusión Vertebral , Perros , Animales , Estudios Prospectivos , Tornillos Óseos/veterinaria , Fluoroscopía/veterinaria , Fusión Vertebral/métodos , Fusión Vertebral/veterinaria , Húmero/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...