Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 823
1.
Cancer Med ; 13(11): e7250, 2024 Jun.
Article En | MEDLINE | ID: mdl-38826090

PURPOSE: Since June 2020, boron neutron capture therapy (BNCT) has been a health care service covered by health insurance in Japan to treat locally advanced or recurrent unresectable head and neck cancers. Therefore, we aimed to assess the clinical outcomes of BNCT as a health insurance treatment and explore its role among the standard treatment modalities for head and neck cancers. MATERIALS AND METHODS: We retrospectively analyzed data from patients who were treated using BNCT at Kansai BNCT Medical Center, Osaka Medical and Pharmaceutical University, between June 2020 and May 2022. We assessed objective response rates based on the Response Evaluation Criteria in Solid Tumors version 1.1, and adverse events based on the Common Terminology Criteria for Adverse Events, version 5.0. Additionally, we conducted a survival analysis and explored the factors that contributed to the treatment results. RESULTS: Sixty-nine patients (72 treatments) were included in the study, with a median observation period of 15 months. The objective response rate was 80.5%, and the 1-year locoregional control, progression-free survival, and overall survival rates were 57.1% (95% confidence interval [CI]: 43.9%-68.3%), 42.2% (95% CI: 30.1%-53.8%), and 75.4% (95% CI: 62.5%-84.5%), respectively. Locoregional control was significantly longer in patients with earlier TNM staging and no history of chemotherapy. CONCLUSIONS: BNCT may be an effective treatment option for locally advanced or recurrent unresectable head and neck cancers with no other definitive therapies. If definitive surgery or radiation therapy are not feasible, BNCT should be considered at early disease stages.


Boron Neutron Capture Therapy , Head and Neck Neoplasms , Humans , Boron Neutron Capture Therapy/methods , Male , Female , Head and Neck Neoplasms/radiotherapy , Head and Neck Neoplasms/therapy , Head and Neck Neoplasms/mortality , Japan , Middle Aged , Aged , Retrospective Studies , Adult , Aged, 80 and over , Treatment Outcome , Insurance, Health , Survival Rate
2.
Sci Rep ; 14(1): 11253, 2024 05 16.
Article En | MEDLINE | ID: mdl-38755333

Accelerator-based boron neutron capture therapy (BNCT) systems employing a solid-state lithium target indicated the reduction of neutron flux over the lifetime of a target, and its reduction could represent the neutron flux model. This study proposes a novel compensatory approach for delivering the required neutron fluence and validates its clinical applicability. The proposed approach relies on the neutron flux model and the cumulative sum of real-time measurements of proton charges. The accuracy of delivering the required neutron fluence for BNCT using the proposed approach was examined in five Li targets. With the proposed approach, the required neutron fluence could be delivered within 3.0%, and within 1.0% in most cases. However, those without using the proposed approach exceeded 3.0% in some cases. The proposed approach can consider the neutron flux reduction adequately and decrease the effect of uncertainty in neutron measurements. Therefore, the proposed approach can improve the accuracy of delivering the required fluence for BNCT even if a neutron flux reduction is expected during treatment and over the lifetime of the Li target. Additionally, by adequately revising the approach, it may apply to other type of BNCT systems employing a Li target, furthering research in this direction.


Boron Neutron Capture Therapy , Lithium , Neutrons , Boron Neutron Capture Therapy/methods , Lithium/chemistry , Humans , Particle Accelerators , Radiotherapy Dosage
3.
Cells ; 13(10)2024 May 08.
Article En | MEDLINE | ID: mdl-38786022

Given the renewed interest in boron neutron capture therapy (BNCT) and the intensified search for improved boron carriers, as well as the difficulties of coherently comparing the carriers described so far, it seems necessary to define a basic set of assays and standardized methods to be used in the early stages of boron carrier development in vitro. The selection of assays and corresponding methods is based on the practical experience of the authors and is certainly not exhaustive, but open to discussion. The proposed tests/characteristics: Solubility, lipophilicity, stability, cytotoxicity, and cellular uptake apply to both low molecular weight (up to 500 Da) and high molecular weight (5000 Da and more) boron carriers. However, the specific methods have been selected primarily for low molecular weight boron carriers; in the case of high molecular weight compounds, some of the methods may need to be adapted.


Boron Compounds , Boron Neutron Capture Therapy , Molecular Weight , Boron Neutron Capture Therapy/methods , Boron Compounds/chemistry , Humans
4.
Biomed Phys Eng Express ; 10(4)2024 May 22.
Article En | MEDLINE | ID: mdl-38744248

Evaluating neutron output is important to ensure proper dose delivery for patients in boron neutron capture therapy (BNCT). It requires efficient quality assurance (QA) and quality control (QC) while maintaining measurement accuracy. This study investigated the optimal measurement conditions for QA/QC of activation measurements using a high-purity germanium (HP-Ge) detector in an accelerator-based boron neutron capture therapy (AB-BNCT) system employing a lithium target. The QA/QC uncertainty of the activation measurement was evaluated based on counts, reproducibility, and standard radiation source uncertainties. Measurements in a polymethyl methacrylate (PMMA) cylindrical phantom using aluminum-manganese (Al-Mn) foils and aluminum-gold (Al-Au) foils and measurements in a water phantom using gold wire with and without cadmium cover were performed to determine the optimal measurement conditions. The QA/QC uncertainties of the activation measurements were 4.5% for Au and 4.6% for Mn. The optimum irradiation proton charge and measurement time were determined to be 36 C and 900 s for measurements in a PMMA cylindrical phantom, 7.0 C and 900 s for gold wire measurements in a water phantom, and 54 C and 900 s at 0-2.2 cm depth and 3,600 s at deeper depths for gold wire measurements with cadmium cover. Our results serve as a reference for determining measurement conditions when performing QA/QC of activation measurements using HP-Ge detectors at an AB-BNCT employing a lithium target.


Boron Neutron Capture Therapy , Lithium , Particle Accelerators , Phantoms, Imaging , Quality Control , Lithium/chemistry , Boron Neutron Capture Therapy/methods , Humans , Particle Accelerators/instrumentation , Reproducibility of Results , Polymethyl Methacrylate/chemistry , Neutrons , Gold/chemistry , Aluminum/chemistry , Water/chemistry , Radiometry/methods , Radiometry/instrumentation , Radiotherapy Dosage
5.
Biomaterials ; 309: 122605, 2024 Sep.
Article En | MEDLINE | ID: mdl-38754291

Multidisciplinary therapy centered on radical surgery for resectable pancreatic cancer is expected to prolong prognosis, but relies on CA19-9 biomarker levels to determine treatment strategy. Boron neutron capture therapy (BNCT) is a chemoradiotherapy using tumor hyperaccumulator boron drugs and neutron irradiation. The purpose of this study is to investigate novel boron drug agents for BNCT for pancreatic cancer. Bioinformatics was used to evaluate the uptake of current boron amino acid (BPA) drugs for BNCT into pancreatic cancer. The expression of the amino acid transporter LAT1, a BPA uptake transporter, was low in pancreatic cancer and even lower in high CA19-9 pancreatic cancer. In contrast, the glucose transporter was high in high CA19-9 pancreatic cancers and inversely correlated with LAT1 expression. Considering the low EPR effect in pancreatic cancer, we synthesized a small molecule Glucose-BSH, which is boron BSH bound to glucose, and confirmed its specific uptake in pancreatic cancer. uptake of Glucose-BSH was confirmed in an environment compatible with the tumor microenvironment. The therapeutic efficacy and safety of Glucose-BSH by therapeutic neutron irradiation were confirmed with BNCT. We report Glucose-BSH boron drug discovery study of a Precision Medicine BNCT with application to high CA19-9 pancreatic cancer.


Boron Neutron Capture Therapy , Glucose , Pancreatic Neoplasms , Boron Neutron Capture Therapy/methods , Pancreatic Neoplasms/therapy , Pancreatic Neoplasms/pathology , Humans , Glucose/metabolism , Cell Line, Tumor , Animals , Boron Compounds/chemistry , Boron Compounds/therapeutic use , Boron/chemistry , Female , Mice, Nude
7.
J Neurooncol ; 168(1): 91-97, 2024 May.
Article En | MEDLINE | ID: mdl-38598087

PURPOSE: Boron neutron capture therapy (BNCT) is a tumor cell-selective particle-radiation therapy. In BNCT, administered p-boronophenylalanine (BPA) is selectively taken up by tumor cells, and the tumor is irradiated with thermal neutrons. High-LET α-particles and recoil 7Li, which have a path length of 5-9 µm, are generated by the capture reaction between 10B and thermal neutrons and selectively kill tumor cells that have uptaken 10B. Although BNCT has prolonged the survival time of malignant glioma patients, recurrences are still to be resolved. miRNAs, that are encapsulated in small extracellular vesicles (sEVs) in body fluids and exist stably may serve critical role in recurrence. In this study, we comprehensively investigated microRNAs (miRNAs) in sEVs released from post-BNCT glioblastoma cells. METHOD: Glioblastoma U87 MG cells were treated with 25 ppm of BPA in the culture media and irradiated with thermal neutrons. After irradiation, they were plated into dishes and cultured for 3 days in the 5% CO2 incubator. Then, sEVs released into the medium were collected by column chromatography, and miRNAs in sEVs were comprehensively investigated using microarrays. RESULT: An increase in 20 individual miRNAs (ratio > 2) and a decrease in 2 individual miRNAs (ratio < 0.5) were detected in BNCT cells compared with non-irradiated cells. Among detected miRNAs, 20 miRNAs were associated with worse prognosis of glioma in Kaplan Meier Survival Analysis of overall survival in TCGA. CONCLUSION: These miRNA after BNCT may proceed tumors, modulate radiation resistance, or inhibit invasion and affect the prognosis of glioma.


Boron Neutron Capture Therapy , Brain Neoplasms , Extracellular Vesicles , Glioblastoma , MicroRNAs , Boron Neutron Capture Therapy/methods , Humans , Extracellular Vesicles/metabolism , Extracellular Vesicles/radiation effects , MicroRNAs/metabolism , MicroRNAs/genetics , Glioblastoma/radiotherapy , Glioblastoma/metabolism , Glioblastoma/pathology , Glioblastoma/genetics , Brain Neoplasms/radiotherapy , Brain Neoplasms/pathology , Brain Neoplasms/genetics , Brain Neoplasms/metabolism , Cell Line, Tumor , Gene Expression Regulation, Neoplastic/radiation effects
8.
Med Phys ; 51(6): 4413-4422, 2024 Jun.
Article En | MEDLINE | ID: mdl-38669482

BACKGROUND: Monte Carlo simulation code is commonly used for the dose calculation of boron neutron capture therapy. In the past, dose calculation was performed assuming a homogeneous mass density and elemental composition inside the tissue, regardless of the patient's age or sex. Studies have shown that the mass density varies with patient to patient, particularly for those that have undergone surgery or radiotherapy. A method to convert computed tomography numbers into mass density and elemental weights of tissues has been developed and applied in the dose calculation process using Monte Carlo codes. A recent study has shown the variation in the computed tomography number between different scanners for low- and high-density materials. PURPOSE: The aim of this study is to investigate the effect of the elemental composition inside each calculation voxel on the dose calculation and the application of the stoichiometric CT number calibration method for boron neutron capture therapy planning. METHODS: Monte Carlo simulation package Particle and Heavy Ion Transport code System was used for the dose calculation. Firstly, a homogeneous cubic phantom with the material set to ICRU soft tissue (four component), muscle, fat, and brain was modelled and the NeuCure BNCT system accelerator-based neutron source was used. The central axis depth dose distribution was simulated and compared between the four materials. Secondly, a treatment plan of the brain and the head and neck region was simulated using a dummy patient dataset. Three models were generated; (1) a model where only the fundamental materials were considered (simple model), a model where each voxel was assigned a mass density and elemental weight using (2) the Nakao20 model, and (3) the Schneider00 model. The irradiation conditions were kept the same between the different models (irradiation time and irradiation field size) and the near maximum (D1%) and mean dose to the organs at risk were calculated and compared. RESULTS: A maximum percentage difference of approximately 5% was observed between the different materials for the homogeneous phantom. With the dummy patient plan, a large dose difference in the bone (greater than 12%) and region near the low-density material (mucosal membrane, 7%-11%) was found between the different models. CONCLUSIONS: A stoichiometric CT number calibration method using the newly developed Nakao20 model was applied to BNCT dose calculation. The results indicate the importance of calibrating the CT number to elemental composition for each individual CT scanner for the purpose of BNCT dose calculation along with the consideration of heterogeneity of the material composition inside the defined region of interest.


Boron Neutron Capture Therapy , Monte Carlo Method , Phantoms, Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Tomography, X-Ray Computed , Boron Neutron Capture Therapy/methods , Calibration , Humans , Radiotherapy Planning, Computer-Assisted/methods , Radiation Dosage , Head and Neck Neoplasms/radiotherapy , Head and Neck Neoplasms/diagnostic imaging
9.
Appl Radiat Isot ; 209: 111330, 2024 Jul.
Article En | MEDLINE | ID: mdl-38657372

Boron neutron capture therapy (BNCT) has received extensive attention as an advanced binary radiotherapy method. However, BNCT still faces poor selectivity of boron agent and is insufficient boron content in tumor tissues. To improve the tumor-targeted ability and boron content, this research aims to design, synthesize and preliminary evaluate a new borane agent Carborane-FAPI, which coupling the o-carborane to the compound skeleton of a mature fibroblast activating protein (FAP) inhibitor (FAPI). FAP is a tumor-associated antigen. FAP expressed lowly in normal organs and highly expressed in tumors, so it is a potential target for diagnosis and treatment. Boronophenylalanine (BPA) is the most widely investigated BNCT drug in present. Compared with BPA, the boron content of a single molecule is increased and drug targeting is enhanced. The results show that Carboaren-FAPI has low toxicity to normal cells, and selective enrichment in tumor tissues. It is a promising boron drug that has the potential to be used in BNCT.


Boranes , Boron Neutron Capture Therapy , Boron , Boron Neutron Capture Therapy/methods , Humans , Animals , Mice , Membrane Proteins/metabolism , Endopeptidases , Serine Endopeptidases/metabolism , Gelatinases/metabolism , Boron Compounds/therapeutic use , Boron Compounds/pharmacokinetics , Cell Line, Tumor
10.
Appl Radiat Isot ; 208: 111303, 2024 Jun.
Article En | MEDLINE | ID: mdl-38531243

Boron neutron capture therapy (BNCT) is an effective binary radiation therapy that depends on nuclear capture reactions. In recent years, BNCT can be performed without a reactor owing to the development of accelerator-based neutron sources. A new BNCT irradiation facility is proposed, which is based on a 15 mA 2.5 MeV proton accelerator with a 100 µm thickness natural lithium target as a neutron converter. A great quantity of studies has shown that neutron beams with different spectra have unique therapeutic effects on tumors. An appropriate neutron beam for BNCT is obtained by Beam Shaping Assembly (BSA) and the moderator plays a main role in determining the BSA outlet beam spectrum. To figure out the dose distribution in phantom with various kinds of neutron spectrum modes during BNCT, a series of cases are calculated by MCNPX code. The results give a database for treatment of brain tumors with BNCT by using different moderators.


Boron Neutron Capture Therapy , Brain Neoplasms , Humans , Boron Neutron Capture Therapy/methods , Brain Neoplasms/radiotherapy , Lithium , Radiotherapy Dosage , Protons , Neutrons , Monte Carlo Method
11.
Radiat Prot Dosimetry ; 200(7): 623-628, 2024 May 08.
Article En | MEDLINE | ID: mdl-38527175

Although boron neutron capture therapy (BNCT) causes minor damage to normal cells owing to the nuclear reactions induced by neutrons with major elements of tissues such as hydrogen and nitrogen, it is useful to estimate the accurate exposure dose for radiation protection. This study aims to estimate the contribution of internal exposure in radiation exposure dose for BNCT. The study was performed by referring to clinical studies at a reactor-based BNCT facility on the basis of computational dosimetry. Five irradiation regions of head and neck were selected for the estimation. The results suggest that external exposure occurred primarily in and around the irradiation field. Furthermore, during the exposure dose estimation in BNCT, internal exposure was found to be not negligible, implying that the irradiation regions in treatment planning must be considered for avoiding damage to certain critical organs that are susceptible to internal exposure.


Boron Neutron Capture Therapy , Boron Neutron Capture Therapy/methods , Humans , Radiotherapy Dosage , Neutrons , Radiation Dosage , Radiometry/methods , Radiation Protection/methods , Radiation Exposure/analysis , Radiotherapy Planning, Computer-Assisted/methods , Monte Carlo Method , Head and Neck Neoplasms/radiotherapy , Phantoms, Imaging , Computer Simulation
12.
Appl Radiat Isot ; 207: 111249, 2024 May.
Article En | MEDLINE | ID: mdl-38428203

The 71Ga(n,γ)72Ga reaction-based epithermal neutron flux detectors are novel instruments developed to measure the epithermal neutron flux of boron neutron capture therapy (BNCT) treatment beams. In this study, a spherical epithermal neutron flux detector using 71Ga(n,γ)72Ga reaction was prototyped. The performance of the detector was experimentally evaluated at an accelerator-based BNCT (AB-BNCT) device developed by Lanzhou University, China. Based on the experimental results and related analysis, we demonstrated that the detector is a reliable tool for the quality assurance of BNCT treatment beams.


Boron Neutron Capture Therapy , Humans , Boron Neutron Capture Therapy/methods , Neutrons , Radiotherapy Dosage , Gamma Rays , Monte Carlo Method
13.
Med Phys ; 51(6): 4524-4535, 2024 Jun.
Article En | MEDLINE | ID: mdl-38299670

BACKGROUND: In boron neutron capture therapy (BNCT)-a form of binary radiotherapy-the primary challenge in treatment planning systems for dose calculations arises from the time-consuming nature of the Monte Carlo (MC) method. Recent progress, including the use of neural networks (NN), has been made to accelerate BNCT dose calculations. However, this approach may result in significant dose errors in both the tumor and the skin, with the latter being a critical organ in BNCT. Furthermore, owing to the lack of physical processes in purely NN-based approaches, their reliability for clinical dose calculations in BNCT is questionable. PURPOSE: In this study, a physically constrained MC-NN (PCMC-NN) coupling algorithm is proposed to achieve fast and accurate computation of the BNCT three-dimensional (3D) therapeutic dose distribution. This approach synergizes the high precision of the MC method with the speed of the NN and utilizes physical conservation laws to constrain the coupling process. It addresses the time-consuming issue of the traditional MC method while reducing dose errors. METHODS: Clinical data were collected from 113 glioblastoma patients. For each patient, the 3D dose distributions for both the coarse and detailed dose grids were calculated using the MC code PHITS. Among these patients, the data from 14 patients were allocated to the test set, 9 to the validation set, and the remaining to the training set. A neural network, 3D-Unet, was built based on the coarse grid dose and patient CT information to enable fast and accurate computation of the 3D detailed grid dose distribution of BNCT. RESULTS: Statistical evaluations, including relative deviation, dose deviation, mean absolute error (MAE), and mean absolute percentage error (MAPE) were conducted. Our findings suggested that the PCMC-NN algorithm substantially outperformed the traditional NN and interpolation methods. Furthermore, the proposed algorithm significantly reduced errors, particularly in the skin and GTV, and improved computational accuracy (hereinafter referred to simply as 'accuracy') with a MAPE range of 1.6%-4.0% and a maximum MAE of 0.3 Gy (IsoE) for different organs. The dose-volume histograms generated by the PCMC-NN aligned well with those obtained from the MC method, further validating its accuracy. CONCLUSIONS: The PCMC-NN algorithm enhanced the speed and accuracy of BNCT dose calculations by combining the MC method with the NN algorithm. This indicates the significant potential of the proposed algorithm for clinical applications in optimizing treatment planning.


Algorithms , Boron Neutron Capture Therapy , Monte Carlo Method , Neural Networks, Computer , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Boron Neutron Capture Therapy/methods , Humans , Radiotherapy Planning, Computer-Assisted/methods , Radiation Dosage
14.
Chem Rev ; 124(5): 2441-2511, 2024 03 13.
Article En | MEDLINE | ID: mdl-38382032

Boron-containing compounds (BCC) have emerged as important pharmacophores. To date, five BCC drugs (including boronic acids and boroles) have been approved by the FDA for the treatment of cancer, infections, and atopic dermatitis, while some natural BCC are included in dietary supplements. Boron's Lewis acidity facilitates a mechanism of action via formation of reversible covalent bonds within the active site of target proteins. Boron has also been employed in the development of fluorophores, such as BODIPY for imaging, and in carboranes that are potential neutron capture therapy agents as well as novel agents in diagnostics and therapy. The utility of natural and synthetic BCC has become multifaceted, and the breadth of their applications continues to expand. This review covers the many uses and targets of boron in medicinal chemistry.


Boranes , Boron Neutron Capture Therapy , Neoplasms , Humans , Boron/chemistry , Chemistry, Pharmaceutical , Boron Compounds/chemistry , Neoplasms/drug therapy , Boronic Acids , Boron Neutron Capture Therapy/methods
15.
Med Phys ; 51(5): 3711-3724, 2024 May.
Article En | MEDLINE | ID: mdl-38205862

BACKGROUND: In Japan, the clinical treatment of boron neutron capture therapy (BNCT) has been applied to unresectable, locally advanced, and recurrent head and neck carcinomas using an accelerator-based neutron source since June of 2020. Considering the increase in the number of patients receiving BNCT, efficiency of the treatment planning procedure is becoming increasingly important. Therefore, novel and rapid dose calculation algorithms must be developed. We developed a novel algorithm for calculating neutron flux, which comprises of a combination of a Monte Carlo (MC) method and a method based on the removal-diffusion (RD) theory (RD calculation method) for the purpose of dose calculation of BNCT. PURPOSE: We present the details of our novel algorithm and the verification results of the calculation accuracy based on the MC calculation result. METHODS: In this study, the "MC-RD" calculation method was developed, wherein the RD calculation method was used to calculate the thermalization process of neutrons and the MC method was used to calculate the moderation process. The RD parameters were determined by MC calculations in advance. The MC-RD calculation accuracy was verified by comparing the results of the MC-RD and MC calculations with respect to the neutron flux distributions in each of the cubic and head phantoms filled with water. RESULTS: Comparing the MC-RD calculation results with those of MC calculations, it was found that the MC-RD calculation accurately reproduced the thermal neutron flux distribution inside the phantom, with the exception of the region near the surface of the phantom. CONCLUSIONS: The MC-RD calculation method is useful for the evaluation of the neutron flux distribution for the purpose of BNCT dose calculation, except for the region near the surface.


Algorithms , Boron Neutron Capture Therapy , Monte Carlo Method , Neutrons , Radiotherapy Planning, Computer-Assisted , Boron Neutron Capture Therapy/methods , Neutrons/therapeutic use , Radiotherapy Planning, Computer-Assisted/methods , Diffusion , Radiotherapy Dosage , Phantoms, Imaging , Humans
16.
Int J Radiat Biol ; 100(4): 609-618, 2024.
Article En | MEDLINE | ID: mdl-38190436

PURPOSE: The current study aimed to investigate boron carbide and boric acid nanoparticles (NPs) as absorbents for thermal neutrons and high-density polyethylene (HDPE) as a substrate and neutron moderator for fast neutrons. The goal was to assess the performance of boron carbide and boric acid NPs based on HDPE as a nanoshield of photoneutrons from medical linear accelerators. MATERIALS AND METHODS: This study was conducted in two parts of simulation and practice. The Monte Carlo (MC) simulation involved modeling and verification of the single-layer, double-layer, and combined nanoshields by selecting nanomaterials and substrates and, finally, calculating the macroscopic cross-sections. The practical part involved manufacturing nanoshields based on the simulation results and evaluating the manufactured nanocomposites via experimental measurements. RESULTS: MC simulation results with an uncertainty of less than 1% showed that for the monolayer samples, the best result belonged to boron carbide at a concentration of 10% and a macroscopic cross-section of 0.933 cm-1. At a concentration of 20%, the highest value among the double-layer samples was 0.936 cm-1 and for the combined samples, this value was 0.928 cm-1. Boron carbide single-layer nanocomposites at a 10% concentration, as well as the bilayer nanoshield of 10% boron carbide and 20% boric acid performed well; however, the best performance belonged to the nanoshield with a macroscopic cross-section of 0.960 and the combination containing 5% boron carbide and 10% boric acid. CONCLUSIONS: The research suggests that utilizing boron carbide and boric acid nanoshields in combination with HDPE holds promise as a viable approach to protecting from the photoneutrons. Further exploration of these nanocomposite shields and their practical applications is warranted, with the potential to yield significant advancements in radiation therapy safety and efficacy.


Boric Acids , Boron Neutron Capture Therapy , Nanoparticles , Polyethylene , Boron , Boron Compounds , Neutrons , Particle Accelerators , Monte Carlo Method , Boron Neutron Capture Therapy/methods
17.
Sci Rep ; 14(1): 418, 2024 01 03.
Article En | MEDLINE | ID: mdl-38172585

Boron Neutron Capture Therapy (BNCT) is a radiotherapy technique based on the enrichment of tumour cells with suitable 10-boron concentration and on subsequent neutron irradiation. Low-energy neutron irradiation produces a localized deposition of radiation dose caused by boron neutron capture reactions. Boron is vehiculated into tumour cells via proper borated formulations, able to accumulate in the malignancy more than in normal tissues. The neutron capture releases two high-LET charged particles (i.e., an alpha particle and a lithium ion), losing their energy in a distance comparable to the average dimension of one cell. Thus BNCT is selective at the cell level and characterized by high biological effectiveness. As the radiation field is due to the interaction of neutrons with the components of biological tissues and with boron, the dosimetry requires a formalism to express the absorbed dose into photon-equivalent units. This work analyzes a clinical case of an adenoid cystic carcinoma treated with carbon-ion radiotherapy (CIRT), located close to optic nerve and deep-seated as a practical example of how to apply the formalism of BNCT photon isoeffective dose and how to evaluate the BNCT dose distribution against CIRT. The example allows presenting different dosimetrical and radiobiological quantities and drawing conclusions on the potential of BNCT stemming on the clinical result of the CIRT. The patient received CIRT with a dose constraint on the optic nerve, affecting the peripheral part of the Planning Target Volume (PTV). After the treatment, the tumour recurred in this low-dose region. BNCT was simulated for the primary tumour, with the goal to calculate the dose distribution in isoeffective units and a Tumour Control Probability (TCP) to be compared with the one of the original treatment. BNCT was then evaluated for the recurrence in the underdosed region which was not optimally covered by charged particles due to the proximity of the optic nerve. Finally, a combined treatment consisting in BNCT and carbon ion therapy was considered to show the consistency and the potential of the model. For the primary tumour, the photon isoeffective dose distribution due to BNCT was evaluated and the resulted TCP was higher than that obtained for the CIRT. The formalism produced values that are consistent with those of carbon-ion. For the recurrence, BNCT dosimetry produces a similar TCP than that of primary tumour. A combined treatment was finally simulated, showing a TCP comparable to the BNCT-alone with overall dosimetric advantage in the most peripheral parts of the treatment volume. Isoeffective dose formalism is a robust tool to analyze BNCT dosimetry and to compare it with the photon-equivalent dose calculated for carbon-ion treatment. This study introduces for the first time the possibility to combine the dosimetry obtained by two different treatment modalities, showing the potential of exploiting the cellular targeting of BNCT combined with the precision of charged particles in delivering an homogeneous dose distribution in deep-seated tumours.


Boron Neutron Capture Therapy , Head and Neck Neoplasms , Heavy Ion Radiotherapy , Humans , Boron Neutron Capture Therapy/methods , Boron , Carbon , Neutrons
18.
ACS Appl Mater Interfaces ; 16(3): 3232-3242, 2024 Jan 24.
Article En | MEDLINE | ID: mdl-38221726

Accurate prediction of the relative biological effectiveness (RBE) of boron neutron capture therapy (BNCT) is challenging. The therapy is different from other radiotherapy; the dynamic distribution of boron-containing compounds in tumor cells affects the therapeutic outcome considerably and hampers accurate measurement of the neutron-absorbed dose. Herein, we used boron-containing metal-organic framework nanoparticles (BMOFs) with high boron content to target U87-MG cells and maintain the concentration of the 10B isotope in cells. The content of boron in the cells could maintain 90% (60 ppm) within 20 min compared with that at the beginning; therefore, the accurate RBE of BNCT can be acquired. The effects of BNCT upon cells after neutron irradiation were observed, and the neutron-absorbed dose was obtained by Monte Carlo simulations. The RBE of BMOFs was 6.78, which was 4.1-fold higher than that of a small-molecule boron-containing agent (boric acid). The energy spectrum of various particles was analyzed by Monte Carlo simulations, and the RBE was verified theoretically. Our results suggested that the use of nanoparticle-based boron carriers in BNCT may have many advantages and that maintaining a stable boron distribution within cells may significantly improve the efficiency of BNCT.


Boron Neutron Capture Therapy , Boron , Boron Neutron Capture Therapy/methods , Relative Biological Effectiveness , Neutrons
19.
Appl Radiat Isot ; 205: 111184, 2024 Mar.
Article En | MEDLINE | ID: mdl-38215645

Boron neutron capture therapy (BNCT) combines neutron irradiation with boron compounds that are selectively uptaken by tumor cells. Boronophenylalanine (BPA) is a boron compound used to treat malignant brain tumors. The determination of boron concentration in cells is of great relevance to the field of BNCT. This study was designed to develop a novel method for simultaneously measuring the uptake of BPA by U87 and U251 cells (two brain tumor cell lines) and number of cells using inductively coupled plasma atomic emission spectroscopy (ICP-AES). The results revealed a linear correlation between phosphorus intensity and the numbers of U87 and U251 cells, with correlation coefficients (R2) of 0.9995 and 0.9994, respectively. High accuracy and reliability of phosphorus concentration standard curve were also found. Using this new method, we found that BPA had no significant effect on phosphorus concentration in either U87 or U251 cells. However, BPA increased the boron concentration in U87 and U251 cells in a concentration-dependent manner, with the boron concentration in U87 cells being higher than that in U251 cells. In both U87 and U251 cells, boron was mainly distributed in the cytoplasm and nucleus, accounting for 85% and 13% of the total boron uptake by U87 cells and 86% and 11% of the total boron uptake by U251 cells, respectively. In the U87 and U251 cell-derived xenograft (CDX) animal model, tumor exhibited higher boron concentration values than blood, heart, liver, lung, and brain, with a tumor/blood ratio of 2.87 for U87 cells and 3.11 for U251 cells, respectively. These results suggest that the phosphorus concentration in U87 and U251 cells can represent the number of cells and BPA is easily uptaken by tumor cells as well as in tumor tissue.


Boron Neutron Capture Therapy , Brain Neoplasms , Animals , Humans , Spectrophotometry, Atomic , Boron , Reproducibility of Results , Brain Neoplasms/radiotherapy , Brain , Boron Compounds , Phosphorus , Boron Neutron Capture Therapy/methods
20.
Med Phys ; 51(1): 439-446, 2024 Jan.
Article En | MEDLINE | ID: mdl-37956252

BACKGROUND: Boron-containing compounds, such as 4-borono-phenylalanine (BPA) are used as drugs for cancer treatment in the framework of Boron Neutron Capture Therapy (BNCT). Neutron irradiation of boron-rich compounds delivered to cancer cells triggers nuclear reactions that destroy cancer cells. PURPOSE: We provide a modeling of the thermal neutron cross section of BPA, a drug used in Boron Neutron Capture Therapy (BNCT), to quantify the competing contributions of boron absorption against hydrogen scattering, for optimizing BNCT by minimizing the latter. METHODS: We perform the experimental determination of the total neutron scattering cross section of BPA at thermal and epithermal neutron energies using neutron transmission measurements. We isolate the contribution related to the incoherent scattering by hydrogen atoms as a function of the neutron energy by means of the Average Functional Group Approximation, and we calculate the probability for a neutron of being absorbed as a function of the neutron energy both for BPA and for its variants where either one or all four aromatic hydrogen atoms are substituted by 19 F, and both for the samples with natural occurrence or enriched concentration of 10 B. RESULTS: While referring to the already available literature for in vivo use of fluorinated BPA, we show that fluorine-rich variants of BPA increase the probability of neutrons being captured by the molecule. As the higher absorption efficiency of fluorinated BPA does not depend on whether the molecule is used in vivo or not, our results are promising for the higher efficiency of the boron neutron capture treatment. CONCLUSIONS: Our results suggest a new advantage using fluorinated compounds for BNCT, in their optimized interaction with neutrons, in addition to their already known capability to be used for monitoring and pharmacokinetics studies using 19 F-Nuclear Magnetic Resonance or in 18 F-Positron Emission Tomography.


Boron Neutron Capture Therapy , Boron , Boron Neutron Capture Therapy/methods , Phenylalanine/pharmacokinetics , Phenylalanine/therapeutic use , Tomography, X-Ray Computed , Neutrons , Boron Compounds/therapeutic use , Boron Compounds/pharmacokinetics
...