Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
BMJ Case Rep ; 12(12)2019 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-31852692

RESUMEN

Transcatheter aortic valve implantations (TAVIs) may be complicated by a need for permanent pacemaker implantation post procedure, usually due to local trauma or compression on the conduction system. There are some features that might help predict that a patient is high risk for developing conduction disease following TAVI, for example, underlying right bundle branch block or use of certain types of TAVI. It might also become apparent during the procedure, or before temporary wire removal post procedure. Higher risk patients may undergo rhythm monitoring for longer periods post TAVI. We present a case where a patient required an unexpected emergency pacemaker following a TAVI, despite low risk clinical features, a low risk baseline ECG, and the use of a low risk TAVI valve. In addition, this very significant conduction disease only became apparent over 72 hours following implantation, despite normal resting ECGs and telemetry up to that point.


Asunto(s)
Nodo Atrioventricular/diagnóstico por imagen , Trastorno del Sistema de Conducción Cardíaco/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Nodo Atrioventricular/fisiopatología , Trastorno del Sistema de Conducción Cardíaco/diagnóstico por imagen , Trastorno del Sistema de Conducción Cardíaco/etiología , Procedimientos Quirúrgicos Electivos/efectos adversos , Electrocardiografía , Femenino , Humanos , Marcapaso Artificial , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/cirugía , Resultado del Tratamiento
2.
JACC Clin Electrophysiol ; 5(11): 1233-1252, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31753428

RESUMEN

More than 2 decades ago, para-Hisian pacing was introduced to assess the pattern of retrograde conduction during electrophysiological studies. Although there is no ideal maneuver for every patient and condition, para-Hisian pacing is a valuable and handy strategy to differentiate between retrograde conduction over the atrioventricular node and the accessory pathways. The dynamic behavior of para-Hisian pacing, in a region with unique anatomical features, can produce various activation patterns and intriguing electrophysiological phenomena. Although the demonstration of a retrograde nodal activation pattern during para-Hisian pacing does not rule out the presence of an accessory pathway, evidence of retrograde conduction over an accessory pathway does not prove its active role in the culprit tachycardia. Multipolar His bundle recordings, detailed atrial mapping, and recognition of the truly captured structures and the impact of temporal changes of autonomic tone or pacing rates, are essential keys for accurate interpretation of this maneuver that may ultimately guide judicious catheter ablation of the arrhythmic substrate. This review aims to summarize the practical usefulness and potential pitfalls of the para-Hisian pacing maneuver, focusing on the interpretation of electrocardiograms and intracardiac recordings.


Asunto(s)
Fascículo Atrioventricular Accesorio/fisiopatología , Nodo Atrioventricular/fisiopatología , Fascículo Atrioventricular/fisiopatología , Trastorno del Sistema de Conducción Cardíaco/diagnóstico , Técnicas Electrofisiológicas Cardíacas/métodos , Sistema de Conducción Cardíaco/fisiopatología , Trastorno del Sistema de Conducción Cardíaco/cirugía , Estimulación Cardíaca Artificial/métodos , Ablación por Catéter , Humanos
3.
Europace ; 21(9): 1432-1441, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31219547

RESUMEN

AIMS: Potential advantages of real-time magnetic resonance imaging (MRI)-guided electrophysiology (MR-EP) include contemporaneous three-dimensional substrate assessment at the time of intervention, improved procedural guidance, and ablation lesion assessment. We evaluated a novel real-time MR-EP system to perform endocardial voltage mapping and assessment of delayed conduction in a porcine ischaemia-reperfusion model. METHODS AND RESULTS: Sites of low voltage and slow conduction identified using the system were registered and compared to regions of late gadolinium enhancement (LGE) on MRI. The Sorensen-Dice similarity coefficient (DSC) between LGE scar maps and voltage maps was computed on a nodal basis. A total of 445 electrograms were recorded in sinus rhythm (range: 30-186) using the MR-EP system including 138 electrograms from LGE regions. Pacing captured at 103 sites; 47 (45.6%) sites had a stimulus-to-QRS (S-QRS) delay of ≥40 ms. Using conventional (0.5-1.5 mV) bipolar voltage thresholds, the sensitivity and specificity of voltage mapping using the MR-EP system to identify MR-derived LGE was 57% and 96%, respectively. Voltage mapping had a better predictive ability in detecting LGE compared to S-QRS measurements using this system (area under curve: 0.907 vs. 0.840). Using an electrical threshold of 1.5 mV to define abnormal myocardium, the total DSC, scar DSC, and normal myocardium DSC between voltage maps and LGE scar maps was 79.0 ± 6.0%, 35.0 ± 10.1%, and 90.4 ± 8.6%, respectively. CONCLUSION: Low-voltage zones and regions of delayed conduction determined using a real-time MR-EP system are moderately associated with LGE areas identified on MRI.


Asunto(s)
Trastorno del Sistema de Conducción Cardíaco/diagnóstico por imagen , Trastorno del Sistema de Conducción Cardíaco/fisiopatología , Técnicas Electrofisiológicas Cardíacas/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Daño por Reperfusión Miocárdica/fisiopatología , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/fisiopatología , Animales , Trastorno del Sistema de Conducción Cardíaco/etiología , Trastorno del Sistema de Conducción Cardíaco/cirugía , Ablación por Catéter , Modelos Animales de Enfermedad , Imagen por Resonancia Magnética/métodos , Masculino , Daño por Reperfusión Miocárdica/complicaciones , Daño por Reperfusión Miocárdica/diagnóstico por imagen , Cirugía Asistida por Computador , Sus scrofa , Porcinos , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía
4.
Heart Rhythm ; 16(12): 1774-1782, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31136869

RESUMEN

BACKGROUND: His bundle pacing (HBP) is the most physiologic form of pacing but associated with higher thresholds and lower success in patients with His-Purkinje conduction disease. Recent reports have described transvenous left bundle branch area pacing (LBBAP). OBJECTIVE: We aimed to prospectively evaluate the feasibility and the electrophysiologic and echocardiographic characteristics of LBBAP. METHODS: Patients requiring pacing for bradycardia or heart failure indications (failed left ventricular [LV] lead) were prospectively enrolled. LBBAP was performed with a Medtronic 3830 lead. Presence of left bundle branch (LBB) potential, paced QRS morphology/duration, and peak LV activation time (pLVAT) were recorded at implant. Pacing threshold and sensing was assessed at implant and follow-up. Echocardiography was performed to assess the approximate lead location and impact on tricuspid valve function. RESULTS: LBBAP was successful in 93 of 100 (93%) patients. Mean age was 75 ± 13 years; men 69%, left bundle branch block 24%, right bundle branch block 25%, intraventricular conduction defect 8%. Indications for pacing were atrioventricular (AV) block 54%, sinus node dysfunction 23%, AV node ablation 7%, cardiac resynchronization therapy 11%, HBP lead failure 7%. Baseline QRS duration was 133 ± 35 ms. Paced QRS duration was 136 ± 17 ms. LBB potentials were observed in 63 patients with left bundle branch - ventricle (LBB-V) interval of 27 ± 6 ms. pLVAT was 75 ± 16 ms. Pacing threshold at implant was 0.6 ± 0.4 V @ 0.5 ms and R waves were 10 ± 6 mV and remained stable at median follow-up of 3 months. The lead depth in the septum was approximately 1.4 ± 0.23 cm. CONCLUSIONS: LBBAP was feasible in a high percentage of patients with low thresholds during acute follow-up. HBP and LBBAP may significantly increase the overall success of physiologic pacing.


Asunto(s)
Bloqueo Atrioventricular , Fascículo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial , Ecocardiografía/métodos , Electrocardiografía/métodos , Anciano , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/cirugía , Bradicardia/fisiopatología , Bradicardia/terapia , Trastorno del Sistema de Conducción Cardíaco/diagnóstico , Trastorno del Sistema de Conducción Cardíaco/fisiopatología , Trastorno del Sistema de Conducción Cardíaco/cirugía , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Terapia de Resincronización Cardíaca/métodos , Femenino , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Evaluación de Procesos y Resultados en Atención de Salud , Marcapaso Artificial
5.
Heart Rhythm ; 16(4): 511-519, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30744910

RESUMEN

BACKGROUND: Areas of conduction delay (CD) or conduction block (CB) are associated with higher recurrence rates after ablation therapy for atrial fibrillation (AF). OBJECTIVE: Thus far, there are no reports on the quantification of the extensiveness of CD and CB at the pulmonary vein area (PVA) and their clinical relevance. METHODS: Intraoperative high-density epicardial mapping of the PVA (interelectrode distance 2 mm) was performed during sinus rhythm in 268 patients (mean ± SD [minimum-maximum] 67 ± 11 [21-84] years) with and without preoperative AF. For each patient, extensiveness of CD (conduction velocity 17-29 cm/s) and CB (conduction velocity <17 cm/s) was assessed and related to the presence and type of AF. RESULTS: CD and CB occurred in, respectively, 242 (90%) and 183 (68%) patients. Patients with AF showed a higher incidence of continuous conduction delay and block (CDCB) lines (AF: n = 37 [76%]; no AF: n = 132 [60%]; P = .046), a 2-fold number of lines per patient (CD: 7 [0-30] vs 4 [0-22], P < .001; CB: 3 [0-11] vs 1 [0-12], P = .003; CDCB: 2 [0-6] vs 1 [0-8], P = .004), and a higher incidence of CD or CB lines ≥6 mm and CDCB lines ≥16 mm (P = .011, P = .025, and P = .027). The extensiveness of CD, CB, and CDCB could not distinguish between the different AF types. CONCLUSION: Patients with AF more often present with continuous lines of adjacent areas of CD and CB, whereas in patients without AF, lines of CD and CB are shorter and more often separated by areas with normal intra-atrial conduction. However, a considerable overlap in the amount of conduction abnormalities at the PVA was observed between patients with a history of paroxysmal and persistent AF.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter , Sistema de Conducción Cardíaco/fisiopatología , Venas Pulmonares/fisiopatología , Venas Pulmonares/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Trastorno del Sistema de Conducción Cardíaco/fisiopatología , Trastorno del Sistema de Conducción Cardíaco/cirugía , Mapeo Epicárdico , Femenino , Humanos , Masculino , Persona de Mediana Edad
6.
Int J Cardiovasc Imaging ; 35(3): 387-392, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30178222

RESUMEN

To investigate the effectiveness and safety of using the Ensite NavX three-dimensional (3D) mapping system during Radiofrequency catheter ablation (RFCA) of left accessory pathway (AP) disorders. A total of 227 patients having their left AP treated by RFCA, were classified into study group (n = 112) and the control group (n = 115). X-ray irradiation time and exposure doses during the course of the operations were recorded. Time taken to place the mapping catheter along with total duration of operations and procedural complications were compared. The X-ray irradiation time and exposure doses in the course of manipulating the ablation catheters were significantly lower in the study group compared to control (5.1 ± 2.3 min vs. 13.1 ± 3.1 min; P < 0.05 and 5.7 ± 2.6 mGy vs. 17.8 ± 4.3 mGy; P < 0.05, respectively). The total duration of operation was also significantly shorter in the study group compared to control (53.1 ± 18.8 min vs. 62.3 ± 20.6 min; P < 0.05). No procedural complications were reported in both groups. The irradiation time and exposure dose along with total operation duration was significantly reduced when the Ensite NavX mapping system was used during RFCA in comparison with traditional X-ray fluoroscopy method.


Asunto(s)
Fascículo Atrioventricular Accesorio/cirugía , Arritmias Cardíacas/cirugía , Trastorno del Sistema de Conducción Cardíaco/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas , Imagenología Tridimensional , Cirugía Asistida por Computador/métodos , Fascículo Atrioventricular Accesorio/diagnóstico por imagen , Fascículo Atrioventricular Accesorio/fisiopatología , Potenciales de Acción , Adulto , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Trastorno del Sistema de Conducción Cardíaco/diagnóstico , Trastorno del Sistema de Conducción Cardíaco/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Complicaciones Posoperatorias/etiología , Dosis de Radiación , Exposición a la Radiación , Radiografía Intervencional , Estudios Retrospectivos , Factores de Riesgo , Cirugía Asistida por Computador/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
7.
Cardiol Young ; 28(12): 1487-1488, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30326976

RESUMEN

Cardiac conduction disease affects patients with Kearns-Sayre syndrome. We report a young asymptomatic patient with Kearns-Sayre syndrome with abnormal conduction on electrocardiogram and Holter monitor, although not advanced atrioventricular block. She underwent prophylactic pacemaker placement, and rapidly developed complete atrioventricular block, which resulted in 100% ventricular pacing. It may be reasonable to consider prophylactic pacemaker implantation in patients with Kearns-Sayre syndrome with evidence of cardiac conduction disease even without overt atrioventricular block given its unpredictable progression to complete atrioventricular block.


Asunto(s)
Bloqueo Atrioventricular , Síndrome de Kearns-Sayre/complicaciones , Marcapaso Artificial , Procedimientos Quirúrgicos Profilácticos , Bloqueo Atrioventricular/complicaciones , Bloqueo Atrioventricular/prevención & control , Bloqueo Atrioventricular/cirugía , Trastorno del Sistema de Conducción Cardíaco/complicaciones , Trastorno del Sistema de Conducción Cardíaco/cirugía , Niño , Progresión de la Enfermedad , Electrocardiografía , Femenino , Humanos
8.
J Interv Card Electrophysiol ; 52(3): 403-408, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30097789

RESUMEN

AV conduction abnormalities are observed in 15-30% of patients with hypertrophic cardiomyopathy but are usually not severe enough to require permanent pacemaker implant. Both septal myectomy and alcohol septal ablation are effective options to relieve symptoms due to left ventricular outflow tract gradient in patients with hypertrophic cardiomyopathy but have procedure-specific effects on AV conduction and the His Purkinje system. Septal myectomy is associated with the development of LBBB in 50-100% of patients, while alcohol septal ablation is associated with RBBB in 37-70% of patients. Baseline abnormalities in the contralateral bundles and the presence of conduction disease have an important impact on the likelihood of the development of AV block for both of these therapies. AV block requiring permanent pacing occurs in approximately 2-3% of patients after septal myectomy and 10-15% of patients after alcohol septal ablation. Permanent pacemaker implant after alcohol septal ablation is more common in older patients (> 55 years old 13 vs. < 55 years old 5%; p = 0.06). Improved outcomes for septal myectomy and alcohol septal ablation are observed in experienced centers. Septal reduction therapies should be performed at medical centers with a dedicated hypertrophic cardiomyopathy program using a multidisciplinary approach.


Asunto(s)
Nodo Atrioventricular/fisiopatología , Procedimientos Quirúrgicos Cardíacos/métodos , Cardiomiopatía Hipertrófica/cirugía , Ablación por Catéter/métodos , Etanol/uso terapéutico , Nodo Atrioventricular/cirugía , Trastorno del Sistema de Conducción Cardíaco/diagnóstico por imagen , Trastorno del Sistema de Conducción Cardíaco/mortalidad , Trastorno del Sistema de Conducción Cardíaco/cirugía , Estimulación Cardíaca Artificial/métodos , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Femenino , Tabiques Cardíacos/cirugía , Humanos , Masculino , Pronóstico , Medición de Riesgo , Análisis de Supervivencia , Resultado del Tratamiento
9.
Int J Cardiol ; 249: 220-225, 2017 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-28888481

RESUMEN

BACKGROUND: Length of lines of conduction block (CB) during sinus rhythm (SR) at Bachmann's bundle (BB) is associated with atrial fibrillation (AF). However, it is unknown whether extensiveness of CB at BB represents CB elsewhere in the atria. We aim to investigate during SR 1) the spatial distribution and extensiveness of CB 2) whether there is a predilection site for CB and 3) the association between CB and incidence of post-operative AF. METHODS: During SR, epicardial mapping of the right atrium (RA), BB and left atrium was performed in 209 patients with coronary artery disease. The amount of conduction delay (CD, Δlocal activation time ≥7ms) and CB (Δ≥12ms) was quantified as % of the mapping area. Atrial regions were compared to identify potential predilection sites for CD/CB. Correlations between CD/CB and clinical characteristics were tested. RESULTS: Areas with CD or CB were present in all patients, overall prevalence was respectively 1.4(0.2-4.0) % and 1.3(0.1-4.3) %. Extensiveness and spatial distribution of CD/CB varied considerably, however occurred mainly at the superior intercaval RA. Of all clinicalcharacteristics, CD/CB only correlated weakly with age and diabetes (P<0.05). A 1% increase in CD or CB caused a 1.1-1.5ms prolongation of the activation time (P<0.001). There was no correlation between CD/CB and post-operative AF. CONCLUSION: CD/CB during SR in CABG patients with electrically non-remodeled atria show considerable intra-atrial, but also inter-individual variation. Despite these differences, a predilection site is present at the superior intercaval RA. Extensiveness of CB at the superior intercaval RA or BB does not reflect CB elsewhere in the atria and is not associated with post-operative AF.


Asunto(s)
Trastorno del Sistema de Conducción Cardíaco/diagnóstico , Trastorno del Sistema de Conducción Cardíaco/fisiopatología , Mapeo Epicárdico/métodos , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca/fisiología , Anciano , Trastorno del Sistema de Conducción Cardíaco/cirugía , Femenino , Bloqueo Cardíaco/diagnóstico , Bloqueo Cardíaco/fisiopatología , Bloqueo Cardíaco/cirugía , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...