Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 4.751
1.
BMJ Open ; 14(5): e081749, 2024 May 17.
Article En | MEDLINE | ID: mdl-38760049

OBJECTIVES: To compare catheter-related outcomes of individuals who received a tunnelled femorally inserted central catheter (tFICC) with those who received a peripherally inserted central catheter (PICC) in the upper extremities. DESIGN: A propensity-score matched cohort study. SETTING: A 980-bed tertiary referral hospital in South West Sydney, Australia. PARTICIPANTS: In-patients referred to the hospital central venous access service for the insertion of a central venous access device. PRIMARY AND SECONDARY OUTCOME MEASURES: The primary outcome of interest was the incidence of all-cause catheter failure. Secondary outcomes included the rates of catheters removed because of suspected or confirmed catheter-associated infection, catheter dwell and confirmed upper or lower extremity deep vein thrombosis (DVT). RESULTS: The overall rate of all-cause catheter failure in the matched tFICC and PICC cohort was 2.4/1000 catheter days (95% CI 1.1 to 4.4) and 3.0/1000 catheter days (95% CI 2.3 to 3.9), respectively, and when compared, no difference was observed (difference -0.63/1000 catheter days, 95% CI -2.32 to 1.06). We found no differences in catheter dwell (mean difference of 14.2 days, 95% CI -6.6 to 35.0, p=0.910); or in the cumulative probability of failure between the two groups within the first month of dwell (p=0.358). No significant differences were observed in the rate of catheters requiring removal for confirmed central line-associated bloodstream infection (difference 0.13/1000 catheter day, 95% CI -0.36 to 0.63, p=0.896). Similarly, no significant differences were found between the groups for confirmed catheter-related DVT (difference -0.11 per 1000 catheter days, 95% CI -0.26 to 0.04, p=1.00). CONCLUSION: There were no differences in catheter-related outcomes between the matched cohort of tFICC and PICC patients, suggesting that tFICCs are a possible alternative for vascular access when the veins of the upper extremities or thoracic region are not viable for catheterisation.


Catheter-Related Infections , Catheterization, Central Venous , Catheterization, Peripheral , Propensity Score , Humans , Female , Male , Middle Aged , Catheter-Related Infections/epidemiology , Catheter-Related Infections/etiology , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/methods , Catheterization, Peripheral/adverse effects , Aged , Central Venous Catheters/adverse effects , Cohort Studies , Australia/epidemiology , Adult , Catheters, Indwelling/adverse effects , Device Removal/statistics & numerical data , Equipment Failure/statistics & numerical data
2.
Cochrane Database Syst Rev ; 5: CD013023, 2024 May 23.
Article En | MEDLINE | ID: mdl-38780138

BACKGROUND: Peripheral arterial catheters (ACs) are used in anaesthesia and intensive care settings for blood sampling and monitoring. Despite their importance, ACs often fail, requiring reinsertion. Dressings and securement devices maintain AC function and prevent complications such as infection. OBJECTIVES: To evaluate the effectiveness of peripheral AC dressing and securement devices to prevent failure and complications in hospitalised people. SEARCH METHODS: We searched the Cochrane Wounds Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL Plus up to 16 May 2023. We also searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform up to 16 May 2023. SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing different dressing and securement devices for the stabilisation of ACs in hospitalised people. DATA COLLECTION AND ANALYSIS: Two review authors independently selected trials for inclusion, extracted data, and assessed risk of bias using Cochrane's RoB 1 tool. We resolved disagreements by discussion, or by consulting a third review author when necessary. We assessed the certainty of evidence using GRADE. MAIN RESULTS: We included five RCTs with 1228 participants and 1228 ACs. All included studies had high risk of bias in one or more domains. We present the following four comparisons, with the remaining comparisons reported in the main review. Standard polyurethane (SPU) plus tissue adhesive (TA) compared with SPU: we are very uncertain whether use of SPU plus TA impacts rates of AC failure (risk ratio (RR) 0.44, 95% confidence interval (CI) 0.20 to 0.98; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Neither study (165 participants) reported catheter-related bloodstream infections (CRBSI), thus we are very uncertain whether SPU plus TA impacts on the incidence of CRBSI (very low-certainty evidence). It is very uncertain whether use of SPU plus TA impacts AC dislodgement risk (RR 0.54, 95% CI 0.03 to 9.62; I² = 44%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts AC occlusion rates (RR 1.20, 95% CI 0.37 to 3.91; I² = 3%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts rates of adverse events with few reported events across groups (RR 0.89, 95% CI 0.09 to 8.33; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Bordered polyurethane (BPU) compared to SPU: we are very uncertain whether use of BPU impacts rates of AC failure (RR 0.67, 95% CI 0.21 to 2.13; 1 study, 60 participants; very low-certainty evidence). BPU may make little or no difference to CRBSI compared to SPU (RR 3.05, 95% CI 0.12 to 74.45; I² = not applicable as 1 study (60 participants) reported 0 events; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to the risk of AC dislodgement compared with SPU (RR 0.75, 95% CI 0.17 to 3.22; I² = 0%; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to occlusion risk compared with SPU (RR 0.80, 95% CI 0.60 to 1.07; I² = 0%; 2 studies, 572 participants; low-certainty evidence). It is very uncertain whether BPU impacts on the risk of adverse events compared with SPU (RR 0.33, 95% CI 0.01 to 7.87; 1 study, 60 participants; very low-certainty evidence). SPU plus sutureless securement devices (SSD) compared to SPU: we are very uncertain whether SPU plus SSD impacts risk of AC failure compared with SPU (RR 0.78, 95% CI 0.40 to 1.52; I² = 0%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain if SPU plus SSD impacts CRBSI incidence rate with no events in both groups (2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of dislodgement (RR 0.14, 95% CI 0.01 to 2.57; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of AC occlusion (RR 1.94, 95% CI 0.50 to 7.48; I² = 38%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain whether SPU plus SSD impacts on the risk of adverse events (RR 1.94, 95% CI 0.19 to 20.24; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). Integrated securement dressings compared to SPU: integrated securement dressings may result in little or no difference in risk of AC failure compared with SPU (RR 1.96, 95% CI 0.80 to 4.84; 1 study, 105 participants; low-certainty evidence); may result in little or no difference in CRBSI incidence with no events reported (1 study, 105 participants; low-certainty evidence); may result in little or no difference in the risk of dislodgement (RR 0.33, 95% CI 0.04 to 3.04; 1 study, 105 participants; low-certainty evidence), may result in little or no difference in occlusion rates with no events reported (1 study, 105 participants; low-certainty evidence), and may result in little or no difference in the risk of adverse events (RR 0.35, 95% CI 0.01 to 8.45; 1 study, 105 participants; low-certainty evidence). AUTHORS' CONCLUSIONS: There is currently limited rigorous RCT evidence available about the relative clinical effectiveness of AC dressing and securement products. Limitations of current evidence include small sample size, infrequent events, and heterogeneous outcome measurements. We found no clear difference in the incidence of AC failure, CRBSI, or adverse events across AC dressing or securement products including SPU, BPU, SSD, TA, and integrated securement products. The limitations of current evidence means further rigorous RCTs are needed to reduce uncertainty around the use of dressing and securement devices for ACs.


Bandages , Catheter-Related Infections , Catheterization, Peripheral , Polyurethanes , Randomized Controlled Trials as Topic , Humans , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Catheter-Related Infections/prevention & control , Bias , Equipment Failure
3.
PLoS One ; 19(5): e0295347, 2024.
Article En | MEDLINE | ID: mdl-38739611

BACKGROUND: When clinicians need to administer a vasopressor infusion, they are faced with the choice of administration via either peripheral intravenous catheter (PIVC) or central venous catheter (CVC). Vasopressor infusions have traditionally been administered via central venous catheters (CVC) rather than Peripheral Intra Venous Catheters (PIVC), primarily due to concerns of extravasation and resultant tissue injury. This practice is not guided by contemporary randomised controlled trial (RCT) evidence. Observational data suggests safety of vasopressor infusion via PIVC. To address this evidence gap, we have designed the "Vasopressors Infused via Peripheral or Central Access" (VIPCA) RCT. METHODS: The VIPCA trial is a single-centre, feasibility, parallel-group RCT. Eligible critically ill patients requiring a vasopressor infusion will be identified by emergency department (ED) or intensive care unit (ICU) staff and randomised to receive vasopressor infusion via either PIVC or CVC. Primary outcome is feasibility, a composite of recruitment rate, proportion of eligible patients randomised, protocol fidelity, retention and missing data. Primary clinical outcome is days alive and out of hospital up to day-30. Secondary outcomes will include safety and other clinical outcomes, and process and cost measures. Specific aspects of safety related to vasopressor infusions such as extravasation, leakage, device failure, tissue injury and infection will be assessed. DISCUSSION: VIPCA is a feasibility RCT whose outcomes will inform the feasibility and design of a multicentre Phase-3 trial comparing routes of vasopressor delivery. The exploratory economic analysis will provide input data for the full health economic analysis which will accompany any future Phase-3 RCT.


Catheterization, Peripheral , Central Venous Catheters , Critical Illness , Feasibility Studies , Vasoconstrictor Agents , Humans , Vasoconstrictor Agents/administration & dosage , Vasoconstrictor Agents/therapeutic use , Central Venous Catheters/adverse effects , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/methods , Adult , Infusions, Intravenous , Intensive Care Units , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/methods , Male , Female , Randomized Controlled Trials as Topic
4.
J Infus Nurs ; 47(3): 155-162, 2024.
Article En | MEDLINE | ID: mdl-38744240

This study aims to analyze the incidences of peripheral intravenous catheter-related phlebitis and infiltration and the associated risk factors in emergency departments. This descriptive cross-sectional, nonexperimental study was conducted with 300 participants in the emergency department of a university hospital in Türkiye between January 15 and February 15, 2018. The incidence of peripheral intravenous catheter-related phlebitis was 31%, which was grade 1 in 29.7% and grade 2 in 1.3% of the emergency department participants. Additionally, the incidence of peripheral intravenous catheter-related infiltration was 55.4%, including grades 1, 2, and 3 in 36.0%, 12.7%, and 6.7% of the participants, respectively. Incidences of phlebitis and infiltration were related to age, duration of peripheral intravenous catheterization longer than 24 hours, and repeated use of the catheter insertion site. The findings of this study may draw attention to the factors that trigger phlebitis and infiltration due to peripheral intravenous catheter insertions in the emergency department and may guide practices to prevent these complications before they develop. In this context, the Phlebitis Scale and Infiltration Scale developed by the Infusion Nurses Society are recommended to be used in the emergency department.


Catheterization, Peripheral , Emergency Service, Hospital , Phlebitis , Humans , Phlebitis/etiology , Phlebitis/epidemiology , Cross-Sectional Studies , Catheterization, Peripheral/adverse effects , Female , Male , Middle Aged , Adult , Risk Factors , Incidence , Aged , Turkey , Hospitals, University
5.
J Infus Nurs ; 47(3): 190-199, 2024.
Article En | MEDLINE | ID: mdl-38744244

This study aimed to compare patients' experience of pain during ultrasound (US)-guided peripheral venipuncture versus conventional peripheral venipuncture. This randomized clinical trial was conducted at a public university hospital in 2021. Adult patients with indication for intravenous therapy compatible with peripheral intravenous catheters (PIVCs) were included: intervention group (IG), US peripheral venipuncture executed by specialist nurses; control group (CG), conventional peripheral venipuncture executed by clinical practice nurses. The primary outcome was patient experience of pain during the procedure and patient experience related to the PIVC placement method. Sixty-four patients were included, 32 for each group. The pain experienced was none-to-mild in the IG for 25 patients (78.1%) and moderate-to-severe in the CG for 21 patients (65.7%; P < .001). The overall pain rating was 2 (1-3) in the IG and 4 (3-6) in the CG (P < .001). The recommendation of the procedure in IG (net promoter score [NPS] + 90.6%) versus CG (NPS + 18.8%) was considered excellent and good, respectively (P < .001). Patients had less pain and significantly recommended the US-guided procedure. Patient experience with US-guided PIVC, performed by a specialist nurse, was superior to that of conventional peripheral venipuncture.


Phlebotomy , Ultrasonography, Interventional , Humans , Female , Male , Phlebotomy/adverse effects , Middle Aged , Catheterization, Peripheral/adverse effects , Adult , Pain Measurement , Pain/prevention & control , Pain Management/methods , Aged
6.
PLoS One ; 19(5): e0300425, 2024.
Article En | MEDLINE | ID: mdl-38709807

INTRODUCTION: Deep Venous Thrombosis (DVT) due to Peripherally Inserted Central Catheter (PICC) is one of the most threatening complications after device insertion. OBJECTIVE: To assess the rate of PICC-associated DVT and analyze the risk factors associated with this event in cancer and critically ill patients. METHODS: We conducted a descriptive, retrospective cohort study with 11,588 PICCs from December 2014 to December 2019. Patients ≥ 18 years receiving a PICC were included. Pre-and post-puncture variables were collected and a logistic regression was used to identify the independent factors associated with the risk of DVT. RESULTS: The DVT prevalence was 1.8% (n = 213). The median length of PICC use was 15.3 days. The median age was 75 years (18; 107) and 52% were men, 53.5% were critically ill and 29.1% oncological patients. The most common indications for PICC's were intravenous antibiotics (79.1%). Notably, 91.5% of PICC showed a catheter-to-vein ratio of no more than 33%. The tip location method with intracavitary electrocardiogram was used in 43%. Most catheters (67.9%) were electively removed at the end of intravenous therapy. After adjusting for cancer profile ou chemotherapy, regression anaysis revealed that age (OR 1.011; 95% CI 1.002-1.020), previous DVT (OR 1.96; 95% CI 1.12-3.44) and obstruction of the device (OR 1.60; 95% CI 1.05-2.42) were independent factors associated with PICC-associated DVT, whereas the use of an anticoagulant regimen was a protective variable (OR 0.73; 95% CI 0.54-0.99). CONCLUSION: PICC is a safe and suitable intravenous device for medium and long-term therapy, with low rates of DVT even in a cohort of critically ill and cancer patients.


Catheterization, Peripheral , Venous Thrombosis , Humans , Male , Female , Aged , Retrospective Studies , Venous Thrombosis/etiology , Venous Thrombosis/epidemiology , Middle Aged , Brazil/epidemiology , Catheterization, Peripheral/adverse effects , Risk Factors , Adult , Aged, 80 and over , Neoplasms/complications , Neoplasms/drug therapy , Catheterization, Central Venous/adverse effects , Critical Illness , Adolescent , Young Adult , Prevalence
7.
PLoS One ; 19(5): e0303152, 2024.
Article En | MEDLINE | ID: mdl-38722995

INTRODUCTION: Short peripheral intravenous catheter (PIVC) failure is a common complication that is generally underdiagnosed. Some studies have evaluated the factors associated with these complications, but the impact of care complexity individual factors and nurse staffing levels on PIVC failure is still to be assessed. The aim of this study was to determine the incidence and risk factors of PIVC failure in the public hospital system of the Southern Barcelona Metropolitan Area. METHODS: A retrospective multicentre observational cohort study of hospitalised adult patients was conducted in two public hospitals in Barcelona from 1st January 2016 to 31st December 2017. All adult patients admitted to the hospitalisation ward were included until the day of discharge. Patients were classified according to presence or absence of PIVC failure. The main outcomes were nurse staffing coverage (ATIC patient classification system) and 27-care complexity individual factors. Data were obtained from electronic health records in 2022. RESULTS: Of the 44,661 patients with a PIVC, catheter failure was recorded in 2,624 (5.9%) patients (2,577 [5.8%] phlebitis and 55 [0.1%] extravasation). PIVC failure was more frequent in female patients (42%), admitted to medical wards, unscheduled admissions, longer catheter dwell time (median 7.3 vs 2.2 days) and those with lower levels of nurse staffing coverage (mean 60.2 vs 71.5). Multivariate logistic regression analysis revealed that the female gender, medical ward admission, catheter dwell time, haemodynamic instability, uncontrolled pain, communication disorders, a high risk of haemorrhage, mental impairments, and a lack of caregiver support were independent factors associated with PIVC failure. Moreover, higher nurse staffing were a protective factor against PIVC failure (AUC, 0.73; 95% confidence interval [CI]: 0.72-0.74). CONCLUSION: About 6% of patients presented PIVC failure during hospitalisation. Several complexity factors were associated with PIVC failure and lower nurse staffing levels were identified in patients with PIVC failure. Institutions should consider that prior identification of care complexity individual factors and nurse staffing coverage could be associated with a reduced risk of PIVC failure.


Catheterization, Peripheral , Humans , Female , Male , Retrospective Studies , Catheterization, Peripheral/adverse effects , Middle Aged , Aged , Risk Factors , Adult , Personnel Staffing and Scheduling , Equipment Failure/statistics & numerical data , Nursing Staff, Hospital/statistics & numerical data , Hospitalization/statistics & numerical data , Spain/epidemiology
8.
Br J Nurs ; 33(7): S18-S26, 2024 Apr 04.
Article En | MEDLINE | ID: mdl-38578942

Occasionally, the administration of intravenous (IV) therapies can go wrong. Infiltration or extravasation is a complication when a drug or IV therapy leaks into the tissues surrounding the vascular access device. Extravasation can cause serious and often life-changing injuries. Extravasation is often associated with systemic anti-cancer therapy but non-chemotherapy drugs have been reported as having a greater risk of serious complications. This study outlines the first UK Infusion unit evaluation of the ivWatch infusion monitoring device which was undertaken from August 2023 to January 2024. Out of 2254 infusions monitored with ivWatch, the device prevented 122 cases of infiltration and extravasation from causing any harm to the patient, corresponding to a 5.4% 'check IV' notification rate.


Catheterization, Peripheral , Nursing Care , Vascular Access Devices , Humans , Infusions, Intravenous , Extravasation of Diagnostic and Therapeutic Materials , Vascular Access Devices/adverse effects , Catheterization, Peripheral/adverse effects
9.
Br J Nurs ; 33(7): S28-S34, 2024 Apr 04.
Article En | MEDLINE | ID: mdl-38578937

INTRODUCTION: First-insertion success rates for peripheral vascular access devices (PVADs) in patients with difficult venous access (DIVA) are low, which negatively affects staff workload, patient experience, and organizational cost. There is mixed evidence regarding the impact of a peripheral vascular access device with retractable coiled tip guidewire (GW; AccuCath™, BD) on the first-insertion success rate. The aim of this study is to investigate whether the use of long GW-PVADs, compared with standard PVADs, reduces the risk of first-time insertion failure, in patients admitted to emergency departments (EDs). METHODS AND ANALYSIS: A parallel-group, two-arm, randomized controlled trial will be carried out in two Australian EDs to compare long GW-PVADs (5.8 cm length) against standard care PVADs (short or long). Patients ≥18 years of age meeting DIVA criteria will be eligible for the trial. The sample size is 203 participants for each arm. Web-based central randomization will be used to ensure allocation concealment. Neither clinicians nor patients can be blinded to treatment allocation. Primary outcome is the first-insertion success rate. Secondary outcomes include the number of insertion attempts, time to insert PVAD, all-cause failure, dwell-time, patient-reported pain, serious adverse events, complications, subsequent vascular access devices required, patient satisfaction, staff satisfaction, and healthcare costs. Differences between the two groups will be analyzed using Cox proportional hazards regression. Cost-effectiveness analysis will also be conducted. Intention-to-treat analysis will be used. ETHICS AND DISSEMINATION: The study is approved by Metro South Ethics Committee (HREC/2022/QMS/82264) and Griffith University (2022/077). The findings will be published in a peer-reviewed journal. TRIAL REGISTRATION: ACTRN12622000299707.


Catheterization, Peripheral , Hospitalization , Humans , Administration, Intravenous , Australia , Catheterization, Peripheral/adverse effects , Catheters , Emergency Service, Hospital , Randomized Controlled Trials as Topic , Adolescent , Young Adult , Adult , Middle Aged , Aged , Aged, 80 and over
10.
Perfusion ; 39(1_suppl): 23S-38S, 2024 Apr.
Article En | MEDLINE | ID: mdl-38651584

Limb ischaemia is a clinically relevant complication of venoarterial extracorporeal membrane oxygenation (VA ECMO) with femoral artery cannulation. No selective distal perfusion or other advanced techniques were used in the past to maintain adequate distal limb perfusion. A more recent trend is the shift from the reactive or emergency management to the pro-active or prophylactic placement of a distal perfusion cannula to avoid or reduce limb ischaemia-related complications. Multiple alternative cannulation techniques to the distal perfusion cannula have been developed to maintain distal limb perfusion, including end-to-side grafting, external or endovascular femoro-femoral bypass, retrograde limb perfusion (e.g., via the posterior tibial, dorsalis pedis or anterior tibial artery), and, more recently, use of a bidirectional cannula. Venous congestion has also been recognized as a potential contributing factor to limb ischaemia development and specific techniques have been described with facilitated venous drainage or bilateral cannulation being the most recent, to reduce or avoid venous stasis as a contributor to impaired limb perfusion. Advances in monitoring techniques, such as near-infrared spectroscopy and duplex ultrasound analysis, have been applied to improve decision-making regarding both the monitoring and management of limb ischaemia. This narrative review describes the evolution of techniques used for distal limb perfusion during peripheral VA ECMO.


Extracorporeal Membrane Oxygenation , Femoral Artery , Humans , Extracorporeal Membrane Oxygenation/methods , Perfusion/methods , Catheterization/methods , Ischemia/prevention & control , Ischemia/etiology , Adult , Catheterization, Peripheral/methods , Catheterization, Peripheral/adverse effects , Extremities/blood supply
13.
Crit Care Sci ; 36: e20240235en, 2024.
Article En, Pt | MEDLINE | ID: mdl-38597484

BACKGROUND: Newborn infants admitted to the neonatal intensive care unit require arterial cannulation for hemodynamic monitoring and blood sampling. Arterial access is achieved through catheterization of umbilical or peripheral arteries. Peripheral artery cannulation is performed in critically ill newborns, but artery localization and cannulation is often challenging and unsuccessful. Therefore, increasing the internal diameter and preventing vasospasm are important for successful peripheral artery cannulation in neonates. Topical glyceryl trinitrate has the potential to increase cannulation success by relaxing arterial smooth muscles and thus increasing the internal diameter. We aim to conduct a pilot randomized controlled trial to evaluate the efficacy and safety of topycal glyceryl trinitrate in increasing the diameter of the radial artery in neonates. METHODS/DESIGN: This study will be a single-center, observer-blind, randomized, placebo-controlled trial conducted in the neonatal intensive care unit of Perth Children's Hospital, Western Australia. A total of 60 infants born at >34 weeks of gestation who are admitted for elective surgery or medical reasons and for whom a peripheral arterial line is needed for sampling or blood pressure monitoring will be recruited after informed parental consent is obtained. The primary outcome will be the change in radial arterial diameter from baseline to postintervention. Secondary outcomes will be the absolute and percentage change from baseline in the radial arterial diameter in both limbs and safety (hypotension and methemoglobinemia). DISCUSSION: This will be the first randomized controlled trial evaluating the use of topical glyceryl trinitrate to facilitate peripheral artery cannulation in neonates. If our pilot randomized controlled trial confirms the benefits of glyceryl trinitrate patches, it will pave the way for large multicenter randomized controlled trials in this field.


Catheterization, Peripheral , Nitroglycerin , Infant , Child , Humans , Infant, Newborn , Nitroglycerin/therapeutic use , Radial Artery , Catheterization, Peripheral/adverse effects , Western Australia , Randomized Controlled Trials as Topic , Multicenter Studies as Topic
14.
JACC Cardiovasc Interv ; 17(8): 979-988, 2024 Apr 22.
Article En | MEDLINE | ID: mdl-38658126

BACKGROUND: Symptomatic patients with severe aortic stenosis (AS) at high risk for surgical aortic valve replacement (SAVR) sustain comparable improvements in health status over 5 years after transcatheter aortic valve replacement (TAVR) or SAVR. Whether a similar long-term benefit is observed among intermediate-risk AS patients is unknown. OBJECTIVES: The purpose of this study was to assess health status outcomes through 5 years in intermediate risk patients treated with a self-expanding TAVR prosthesis or SAVR using data from the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial. METHODS: Intermediate-risk patients randomized to transfemoral TAVR or SAVR in the SURTAVI trial had disease-specific health status assessed at baseline, 30 days, and annually to 5 years using the Kansas City Cardiomyopathy Questionnaire (KCCQ). Health status was compared between groups using fixed effects repeated measures modelling. RESULTS: Of the 1,584 patients (TAVR, n = 805; SAVR, n = 779) included in the analysis, health status improved more rapidly after TAVR compared with SAVR. However, by 1 year, both groups experienced large health status benefits (mean change in KCCQ-Overall Summary Score (KCCQ-OS) from baseline: TAVR: 20.5 ± 22.4; SAVR: 20.5 ± 22.2). This benefit was sustained, albeit modestly attenuated, at 5 years (mean change in KCCQ-OS from baseline: TAVR: 15.4 ± 25.1; SAVR: 14.3 ± 24.2). There were no significant differences in health status between the cohorts at 1 year or beyond. Similar findings were observed in the KCCQ subscales, although a substantial attenuation of benefit was noted in the physical limitation subscale over time in both groups. CONCLUSIONS: In intermediate-risk AS patients, both transfemoral TAVR and SAVR resulted in comparable and durable health status benefits to 5 years. Further research is necessary to elucidate the mechanisms for the small decline in health status noted at 5 years compared with 1 year in both groups. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).


Aortic Valve Stenosis , Aortic Valve , Femoral Artery , Health Status , Heart Valve Prosthesis , Quality of Life , Recovery of Function , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Female , Male , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Aged , Aged, 80 and over , Risk Factors , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Risk Assessment , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Catheterization, Peripheral/adverse effects , Punctures , Prosthesis Design
15.
J Vasc Interv Radiol ; 35(6): 825-833, 2024 Jun.
Article En | MEDLINE | ID: mdl-38484911

PURPOSE: To assess the analgesic and anxiolytic effects of virtual reality (VR) augmentation in patients undergoing peripherally inserted central catheter (PICC) placement or fine-needle aspiration thyroid biopsy. MATERIALS AND METHODS: This is a prospective, single-center randomized controlled trial with 107 patients enrolled. Patients were randomly assigned to receive standard of care (SOC) or SOC+VR during PICC or thyroid biopsy procedures. Pain and anxiety were individually measured using the visual analog scale (VAS) before and after the procedure. Vital signs including heart rate and systolic and diastolic blood pressure were recorded. One-way analysis of variance test and Games-Howell post hoc analysis were used to assess effect size and statistical significance between SOC and SOC+VR measures. RESULTS: The PICC cohort consisted of 59 patients (33 in SOC+VR and 26 in SOC), with a median age of 53.1 years (interquartile range [IQR], 38.3-62.7 years). The thyroid biopsy cohort consisted of 48 patients (26 in SOC+VR and 22 in SOC), with a median age of 60.1 years (IQR, 49.0-67.2 years). One-way analysis of individuals undergoing thyroid biopsies with adjunctive VR revealed an effect size of -1.74 points (SE ± 0.71; P = .018) on VAS pain scale when compared with SOC. Analysis of individuals undergoing PICC placements revealed an effect size of -1.60 points (SE ± 0.81; P = .053) on VAS anxiety when compared with SOC. CONCLUSIONS: VR as a nonpharmacologic adjunct reduced some procedure-related pain and anxiety without increasing the procedural duration.


Anxiety , Catheterization, Peripheral , Pain Measurement , Humans , Middle Aged , Male , Female , Prospective Studies , Pilot Projects , Anxiety/prevention & control , Adult , Aged , Catheterization, Peripheral/adverse effects , Treatment Outcome , Pain Management , Pain, Procedural/etiology , Pain, Procedural/prevention & control , Pain, Procedural/diagnosis , Catheterization, Central Venous/adverse effects , Virtual Reality , Virtual Reality Exposure Therapy , Radiography, Interventional
16.
Medicine (Baltimore) ; 103(12): e37184, 2024 Mar 22.
Article En | MEDLINE | ID: mdl-38518044

To investigate the incidence, risk factors, and pathogenic characteristics of catheter-related bloodstream infection caused by peripherally inserted central venous catheter in neonates, and to provide references for reducing the infection rate of peripherally inserted central venous catheter. The clinical data of 680 neonates who underwent peripherally inserted central catheter (PICC) in the neonatal intensive care unit from June 2020 to June 2023 were retrospectively analyzed. The risk factors and independent risk factors of catheter-related bloodstream infection caused by PICC were determined by univariate and multivariate analysis, respectively. Catheter-related bloodstream infection occurred in 38 of 680 neonates who underwent PICC. The infection rate was 4.74%. The proportions of fungi, gram-positive bacteria, and gram-negative bacteria were 42.11%, 36.84%, and 21.05%, respectively. Candida parapsilosis was the main fungus (18.42%), coagulase negative Staphylococcus was the main gram-positive bacteria (23.68%), and Klebsiella pneumoniae and Escherichia coli were the main gram-negative bacteria (7.89%). Univariate analysis showed that gestational age ≤32 weeks, birth weight ≤1500 g, congenital diseases, nutritional support, catheterization time, 5-minute APGAR score ≤7, and neonatal respiratory distress syndrome were associated with catheter-related bloodstream infection caused by PICC. Multivariate analysis showed that premature delivery, low birth weight, parenteral nutrition, long catheterization time, and 5-minute APGAR score ≤7 were associated with catheter-related bloodstream infection caused by PICC. Among the pathogens detected, there were 6 cases of K pneumoniae, 5 cases of coagulase negative staphylococci, and 2 cases of fungi. Low birth weight, premature delivery, off-site nutrition, long catheterization time, and 5-minute APGAR score ≤7 are independent risk factors for catheter-related bloodstream infection in neonates with peripherally inserted central venous catheters. The pathogenic bacteria are fungi and multidrug-resistant bacteria.


Catheter-Related Infections , Catheterization, Central Venous , Catheterization, Peripheral , Central Venous Catheters , Sepsis , Infant, Newborn , Humans , Infant , Retrospective Studies , Coagulase , Catheter-Related Infections/microbiology , Sepsis/etiology , Catheterization, Peripheral/adverse effects , Risk Factors , Catheterization, Central Venous/adverse effects
17.
Child Care Health Dev ; 50(2): e13250, 2024 03.
Article En | MEDLINE | ID: mdl-38529773

BACKGROUND: Obtaining peripheral intravenous catheter (PIVC) access in children with severe neurological impairment (SNI) is often challenging and commonly associated with complications, including dislodgement, phlebitis and extravasation. In severe cases, extravasation injury may lead to tissue necrosis, ulceration and long-term morbidity. The aim of this study was to determine the relative incidence of PIVC complications secondary to lower limb cannulation, compared to upper limb, in children with SNI. METHODS: A single centre, retrospective, observational review was conducted. Patients with SNI, admitted at a tertiary paediatric centre over 6 months between July and December 2022, were included. RESULTS: One-hundred fifty-five PIVC procedures were conducted in 110 children over the study period. Complications were more common in lower limb PIVCs (12/16, 75%) compared to upper limb (58/139, 42%), p = 0.01. CONCLUSION: Upper limb cannulation is preferred in children with SNI.


Catheterization, Peripheral , Child , Humans , Retrospective Studies , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/methods , Upper Extremity , Hospitalization , Incidence
18.
Support Care Cancer ; 32(4): 239, 2024 Mar 21.
Article En | MEDLINE | ID: mdl-38512390

PURPOSE: To identify the trends in the prevalence of peripherally inserted central catheter (PICC) related complications in cancer patients and explore the risk factors for complications and occurrence speed. METHODS: A total of 3573 cancer patients with PICC were recruited at 17 hospitals from 2016 to 2022. Logistic and COX regression were performed to identify influencing factors of PICC-related complications and incidence speed, respectively. RESULTS: The proportion of symptomatic PICC-related thrombosis, phlebitis, and infections reported had decreased from 59.1% (in 2017), 11.9% (in 2016), and 11.1% (in 2016) to 15.3% (in 2022), 2.9% (in 2022), and 7.4% (in 2022), and adhesive-related skin injuries and bleeding/oozing reported had increased from 4.8% (in 2016) and 0.0% (in 2016) to 45.5% (in 2022) and 3.4% (in 2022), respectively. Catheter occlusion showed a trend of first increasing and then decreasing from 2.4 (in 2016) to 12.0 (in 2020) to 5.8% (in 2022). Logistic regression showed that hospital level, nature, the patient's gender, age, diagnosis, history of deep vein catheterization, chemotherapy drug administration, and type of PICC were influencing factors of complications. COX regression showed that the patient's gender, age, diagnosis, history of deep vein thrombosis and thrombophlebitis, history of deep vein catheterization, chemotherapy drug administration, type of PICC, type of connector, and StatLock used for fixation were influencing factors of incidence speed. CONCLUSION: The composition ratios of PICC-related complications in cancer patients in China have changed in recent years. Chemotherapy drug administration was a significant risk factor accelerating the occurrence of complications. Maintenance factors had the maximum weight on the COX model, followed by patient factors. It is suggested that patients with high-risk factors be closely monitored and proper maintenance be performed to prevent and delay the occurrence of PICC-related complications.


Catheter-Related Infections , Catheterization, Central Venous , Catheterization, Peripheral , Central Venous Catheters , Neoplasms , Humans , Catheterization, Central Venous/adverse effects , Central Venous Catheters/adverse effects , Prevalence , Neoplasms/drug therapy , Risk Factors , Catheterization, Peripheral/adverse effects , Retrospective Studies , Catheter-Related Infections/epidemiology , Catheter-Related Infections/etiology
19.
Catheter Cardiovasc Interv ; 103(5): 722-730, 2024 Apr.
Article En | MEDLINE | ID: mdl-38469945

BACKGROUND: The radial first approach in cardiac catheterization is preferred for its benefits in patient comfort and recovery time. Yet, challenges persist due to characteristics like small, deep, calcified, and mobile radial arteries. Utilizing ultrasound before and during procedures can improve success rates. However, the adoption of its use is still limited and subject to debate. AIM: To utilize routine preprocedural ultrasound (US) and compare US guided with palpation guided radial access, focusing on operator efficiency and outcomes. METHODS AND RESULTS: Consenting adult patients undergoing elective radial cardiac catheterization were divided into palpation and US groups. Routine preprocedural assessment of radial artery characteristics was performed using handheld US. Baseline data, US findings, procedural outcomes, and clinical outcomes were compared in 182 participants (91 in each group). US guided radial access had significantly higher first pass success rates (76.92% vs. 49.45%, p 0.0001), fewer number of attempts (1.46 ± 1 vs. 1.99 ± 1.46, p 0.004), and shorter amount of time (93.62 ± 44.04 vs. 120.44 ± 67.1, p 0.002) compared with palpation guidance. The palpation group had significantly higher incidence of spasm (15.38% vs. 3.3%, p 0.0052). Subgroup analysis indicated consistent benefits of US guidance, especially in calcified radial arteries. CONCLUSION: This prospective, nonrandomized, single-center study demonstrated that real-time procedural US improved the operator's time and effort and enhanced patient comfort compared with palpation. US guidance use was particularly favorable in the presence of calcifications observed on baseline preoperative US.


Catheterization, Peripheral , Adult , Humans , Prospective Studies , Treatment Outcome , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/methods , Palpation/methods , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Radial Artery/diagnostic imaging , Radial Artery/surgery , Ultrasonography, Interventional/methods
20.
PLoS One ; 19(3): e0299692, 2024.
Article En | MEDLINE | ID: mdl-38512885

OBJECTIVE: This study aimed to analyze the prevalence, risk factors, and clinical implications of hemolyzed laboratory samples in the pediatric emergency department (ED), a subject on which existing data remains scarce. METHODS: We conducted a multi-site observational cohort analysis of pediatric ED encounters in Metro Detroit, Michigan, United States. The study included participants below 18 years of age who had undergone peripheral intravenous catheter (PIVC) placement and laboratory testing. The primary outcome was the presence of hemolysis, and secondary outcomes included identifying risk factors for hemolysis and assessing the impact of hemolysis on PIVC failure. RESULTS: Between January 2021 and May 2022, 10,462 ED encounters met inclusion criteria, of which 14.0% showed laboratory evidence of hemolysis. The highest proportion of hemolysis occurred in the infant (age 0-1) population (20.1%). Multivariable regression analysis indicated higher odds of hemolysis for PIVCs placed in the hand/wrist in the toddler (age 2-5) and child (age 6-11) subgroups. PIVCs placed in the hand/wrist also demonstrated higher odds of failure in infants. CONCLUSIONS: Hemolysis in the pediatric ED population is a frequent complication that occurs at similar rates as in adults. PIVCs placed in the hand/wrist were associated with higher odds of hemolysis compared to those placed in the antecubital fossa. Clinicians should consider alternative locations for PIVC placement if clinically appropriate. Further research is needed to better understand the clinical implications of pediatric hemolysis.


Catheterization, Peripheral , Hemolysis , Child , Child, Preschool , Humans , Infant , Infant, Newborn , Catheterization, Peripheral/adverse effects , Emergency Service, Hospital , Prevalence , Risk Factors
...