Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Sci Rep ; 11(1): 10958, 2021 05 26.
Artículo en Inglés | MEDLINE | ID: mdl-34040095

RESUMEN

To propose a new method of reducing the scan length of head trauma while keeping the diagnostic efficiency of the examination in order to develop DRL in an African context. This is a retrospective single-center study including 145 patients who had cranial examinations on a 64-barettes scanner. All head trauma cases were selected. The interpretations of these CT scanners by the three radiologists of the service were noted to determine the acquisition limit. All patient acquisition lengths have been recorded. The acquisition limit for head trauma ended in clinical routine at cervical spine 4 (C4). The average scan length was 23.03 cm. Out of the CT scan results for 145 patients, only 2 (1.37%) had a C3 level cervical spine fracture and 2 (1.37%) at C4. By respecting the principles of radiation protection, this result has shown us that it is possible to limit the acquisition length of the CT scanners indicated for head trauma. The limit of the optimized scan length that we proposed is at cervical spine 2 (98.62%). Now, all head trauma are limited on cervical vertebra 2 in our hospital. The use of this new method is beneficial when the clinical indication of the examination and the type of trauma (multi-trauma) are taken into account. Based on the principles of radiation protection and the clinical indication for the examination, reducing the scan length from C4 to C2 is an effective way to reduce the dose absorbed by the patient.


Asunto(s)
Vértebras Cervicales/diagnóstico por imagen , Traumatismos Craneocerebrales/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Traumatismos del Cuello/diagnóstico por imagen , Adolescente , Adulto , Anciano , Camerún , Vértebras Cervicales/efectos de la radiación , Niño , Preescolar , Femenino , Hematoma Epidural Craneal/diagnóstico por imagen , Hematoma Subdural/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector/efectos adversos , Tomografía Computarizada Multidetector/ética , Órganos en Riesgo , Dosis de Radiación , Traumatismos por Radiación/etiología , Traumatismos por Radiación/prevención & control , Protección Radiológica/legislación & jurisprudencia , Estudios Retrospectivos , Fracturas Craneales/diagnóstico por imagen , Fracturas de la Columna Vertebral/diagnóstico por imagen , Heridas no Penetrantes/diagnóstico por imagen , Adulto Joven
2.
BMC Med Imaging ; 20(1): 104, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32873238

RESUMEN

BACKGROUND: To develop and validate an MRI-based radiomics nomogram for differentiation of cervical spine ORN from metastasis after radiotherapy (RT) in nasopharyngeal carcinoma (NPC). METHODS: A radiomics nomogram was developed in a training set that comprised 46 NPC patients after RT with 95 cervical spine lesions (ORN, n = 51; metastasis, n = 44), and data were gathered from January 2008 to December 2012. 279 radiomics features were extracted from the axial contrast-enhanced T1-weighted image (CE-T1WI). A radiomics signature was created by using the least absolute shrinkage and selection operator (LASSO) algorithm. A nomogram model was developed based on the radiomics scores. The performance of the nomogram was determined in terms of its discrimination, calibration, and clinical utility. An independent validation set contained 25 consecutive patients with 47 lesions (ORN, n = 25; metastasis, n = 22) from January 2013 to December 2015. RESULTS: The radiomics signature that comprised eight selected features was significantly associated with the differentiation of cervical spine ORN and metastasis. The nomogram model demonstrated good calibration and discrimination in the training set [AUC, 0.725; 95% confidence interval (CI), 0.622-0.828] and the validation set (AUC, 0.720; 95% CI, 0.573-0.867). The decision curve analysis indicated that the radiomics nomogram was clinically useful. CONCLUSIONS: MRI-based radiomics nomogram shows potential value to differentiate cervical spine ORN from metastasis after RT in NPC.


Asunto(s)
Neoplasias Óseas/secundario , Vértebras Cervicales/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Carcinoma Nasofaríngeo/radioterapia , Neoplasias Nasofaríngeas/radioterapia , Osteorradionecrosis/diagnóstico por imagen , Adulto , Neoplasias Óseas/diagnóstico por imagen , Vértebras Cervicales/patología , Vértebras Cervicales/efectos de la radiación , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Carcinoma Nasofaríngeo/diagnóstico por imagen , Neoplasias Nasofaríngeas/diagnóstico por imagen , Nomogramas , Variaciones Dependientes del Observador , Osteorradionecrosis/patología , Estudios Retrospectivos
3.
J Appl Clin Med Phys ; 21(4): 22-30, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32170991

RESUMEN

PURPOSE: To investigate the set-up error and consequent dosimetric change in HexaPOD evo RT 6D couch under image-guided intensity-modulated radiotherapy (IG-IMRT) for primary malignant tumor of the cervical spine. METHODS: Ten cases with primary malignant tumor of the cervical spine were treated with intensity-modulated radiotherapy (IMRT) in our hospital from August 2013 to November 2014. The X-ray volumetric images (XVI) were scanned and obtained by cone-beam CT (CBCT). The six directions (6D) of set-up errors of translation and rotation were obtained by planned CT image registration. HexaPOD evo RT 6D couch made online correction of the set-up error, and then the CBCT was conducted to obtain the residual error. RESULTS: We performed set-up error and dosimetric analysis. First, for the set-up error analysis, the average error in three translation directions of 6D set-up error of the primary tumor of the cervical spine was <2 mm, whereas the single maximum error (absolute value) is 7.0 mm. Among average errors of rotation direction, Rotation X (RX) direction 0.67° ± 0.04°, Rotation Y (RY) direction 1.06° ± 0.06°, Rotation Z (RZ) direction 0.78° ± 0.05°; and the single maximum error in three rotation directions were 2.8°, 3.8°, and 2.9°, respectively. On three directions (X, Y, Z axis), the extended distance from clinical target volume (CTV) to planning target volume (PTV) was 3.45, 3.17, and 3.90 mm by calculating, respectively. Then, for the dosimetric analysis, the parameters, including plan sum PTV D98 and D95, planning gross tumor volume D98 and D95, V100% of the plan sum were significantly lower than the treatment plan. Moreover, Dmax of the spinal cord was significantly higher than the treatment plan. CONCLUSION: 6D set-up error correction system should be used for accurate position calibration of precise radiotherapy for patients with malignant tumor of the cervical spine.


Asunto(s)
Neoplasias Óseas/radioterapia , Vértebras Cervicales/efectos de la radiación , Tomografía Computarizada de Haz Cónico , Radiometría/métodos , Errores de Configuración en Radioterapia , Radioterapia de Intensidad Modulada/métodos , Neoplasias de la Columna Vertebral/radioterapia , Adolescente , Adulto , Cordoma/radioterapia , Humanos , Persona de Mediana Edad , Osteosarcoma/radioterapia , Periodo Posoperatorio , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Reproducibilidad de los Resultados , Rotación , Rayos X , Adulto Joven
4.
Radiat Prot Dosimetry ; 187(1): 98-102, 2019 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-31135908

RESUMEN

INTRODUCTION: With regards to the use of ionisation radiation in the computed tomography (CT), optimal parameters should be used to reduce the risk of incidence of secondary cancers in patients who are constantly exposed to X-rays. The aim of this study was to optimise the parameters used in CT scan of cervical vertebrae and neck soft tissue with minimal loss of image quality in emergency patients. MATERIALS AND METHODS: In this study, the patients were divided into two groups. The first group consisted of patients scanned with default parameters and the second group scanned with optimised parameters. All the study has been implemented in emergency settings. The cases included cervical vertebrae and soft tissue protocols. Common CT dose descriptors including weighted computed tomography dose index (CTDIw), volumetric CTDI (CTDIvol), dose length product (DLP), effective dose (ED) and image noise were measured for each group. The ImpactDose program was used to estimate the organs doses. Statistical analysis was performed using Kruskal-Wallis test using SPSS software. RESULTS: There was no significant quality reduction in the optimised images. Decreasing in radiation dose parameters for the soft tissue was: kVp=16.7%, mAs=64.3% and pitch=24.1%, and for the cervical vertebrae was: kVp=16.7%, mAs=54.2% and pitch=48.3%. Consequently, decreasing these parameters reduced CTDIw=81.0%, CTDIvol=90.0% and DLP = 90.2% in the cervical vertebral protocol, as well as CTDIw=75.5%, CTDIvol=81.3% and DLP = 81.4% in the soft tissue protocol. CONCLUSION: Regarding the results, the optimised parameters in the mentioned organ scan reduce the radiation dose in the target area and the organs surrounding. Therefore, these protocols can be used for reducing the risk of cancer.


Asunto(s)
Vértebras Cervicales/efectos de la radiación , Neoplasias de Cabeza y Cuello/radioterapia , Cuello/efectos de la radiación , Neoplasias Inducidas por Radiación/prevención & control , Órganos en Riesgo/efectos de la radiación , Tomografía Computarizada por Rayos X/normas , Adulto , Femenino , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Pronóstico , Dosis de Radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Adulto Joven
5.
Eur J Orthop Surg Traumatol ; 28(4): 579-583, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29396814

RESUMEN

PURPOSE: The O-arm® navigation system allows intraoperative CT imaging that can facilitate highly accurate instrumentation surgery, but radiation exposure is higher than with X-ray radiography. This is a particular concern in pediatric surgery. The purpose of this study is to examine intraoperative radiation exposure in pediatric spinal scoliosis surgery using O-arm. METHODS: The subjects were 38 consecutive patients (mean age 12.9 years, range 10-17) with scoliosis who underwent spinal surgery with posterior instrumentation using O-arm. The mean number of fused vertebral levels was 11.0 (6-15). O-arm was performed before and after screw insertion, using an original protocol for the cervical, thoracic, and lumbar spine doses. RESULTS: The average scanning range was 6.9 (5-9) intervertebral levels per scan, with 2-7 scans per patient (mean 4.0 scans). Using O-arm, the dose per scan was 92.5 (44-130) mGy, and the mean total dose was 401 (170-826) mGy. This dose was 80.2% of the mean preoperative CT dose of 460 (231-736) mGy (P = 0.11). The total exposure dose and number of scans using intraoperative O-arm correlated strongly and significantly with the number of fused levels; however, there was no correlation with the patient's height. CONCLUSIONS: As the fused range became wider, several scans were required for O-arm, and the total radiation exposure became roughly the same as that in preoperative CT. Use of O-arm in our original protocol can contribute to reduction in radiation exposure.


Asunto(s)
Exposición a la Radiación , Escoliosis/cirugía , Cirugía Asistida por Computador/efectos adversos , Tomografía Computarizada por Rayos X/efectos adversos , Adolescente , Tornillos Óseos , Vértebras Cervicales/efectos de la radiación , Niño , Femenino , Humanos , Vértebras Lumbares/efectos de la radiación , Masculino , Dosis de Radiación , Estudios Retrospectivos , Escoliosis/diagnóstico por imagen , Fusión Vertebral/métodos , Cirugía Asistida por Computador/métodos , Vértebras Torácicas/efectos de la radiación
6.
Lasers Med Sci ; 33(3): 627-635, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29383502

RESUMEN

The aim of this study is to evaluate the influences of different bone graft heights on the size of the intervertebral foramen, which will help determine the optimal graft height in clinical practice. Six fresh adult cadavers were used, with the C5-C6 vertebral column segment defined as the functional spinal unit (FSU). After discectomy, the C5/6 intervertebral height was set as the baseline height (normal disc height). We initially used spiral computed tomography (CT) to scan and measure the middle area of the intervertebral foramen when at the baseline height. Data regarding the spatial relationship of C5-C6 were subsequently collected with a laser scanner. Grafting with four different sized grafts, namely, grafts of 100, 130, 160, and 190% of the baseline height, was implanted. Moreover, we scanned to display the FSU in the four different states using Geomagic8.0 studio software. Multiple planar dynamic measurements (MPDM) were adopted to measure the intervertebral foramen volume, middle area, and areas of internal and external opening. MPDM with a laser scanner precisely measured the middle area of the intervertebral foramen as spiral CT, and it is easy to simulate the different grafts implanted. With the increase of the bone graft height, the size of the intervertebral foramen began to decrease after it increased to a certain point, when grafts of 160% of the baseline height implanted. MPDM of the intervertebral foramens with laser scanning three-dimensional (3D) reconstitution are relatively objective and accurate. The recommended optimal graft height of cervical spondylosis is 160% of the mean height of adjacent normal intervertebral spaces.


Asunto(s)
Trasplante Óseo , Vértebras Cervicales/efectos de la radiación , Vértebras Cervicales/trasplante , Disco Intervertebral/anatomía & histología , Disco Intervertebral/efectos de la radiación , Rayos Láser , Adulto , Cadáver , Vértebras Cervicales/diagnóstico por imagen , Femenino , Humanos , Imagenología Tridimensional , Disco Intervertebral/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Rayos X , Adulto Joven
7.
Lasers Med Sci ; 33(4): 737-744, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29204914

RESUMEN

Although low-level laser therapy (LLLT) is an important resource for the treatment of non-specific neck pain patients, the dose which presents the greatest therapeutic potential for the treatment of this pathology is still unclear. The present study aimed to evaluate the immediate effect of LLLT on the muscle fiber conduction velocity (MFCV) and electromyographic activity (EMG) of the upper trapezius (UT) muscle in healthy individuals. A total of 20 healthy subjects were enrolled in a randomized, double-blind, crossover study. Active LLLT (820 nm wavelength, 30 mW, energy total 18 J) or placebo LLLT (pLLLT) was delivered on the UT muscle. Each subject was subjected to a single session of active LLLT and pLLLT. Surface electromyography (sEMG) signal of the UT muscle was recorded during five different step contractions of shoulder elevation force (10-30% maximal voluntary contraction) pre- and post-LLLT irradiation. The values of MFCV and sEMG global amplitude (RMSG) were used to calculate the effects of LLLT. The results showed no difference in the MFCV comparing the LLLT and pLLLT groups (F = 0.72 p = 0.39, η p2 = 0.004). However, a significant difference was observed in the RMSG between the LLLT and pLLLT (F 1,2 = 16.66; P < 0.0001, η p2 = 0.09). Individuals who received active LLLT presented a significant decrease in RMSG after laser application (F = 61.28; p < 0.0001, η p2 = 0.43). In conclusion, the 820 nm LLLT, with energy total of 18 J, did not alter the MFCV but significantly reduced the sEMG signal amplitude of the upper trapezius muscle in healthy subjects to a level of up to 30% of maximal voluntary contraction.


Asunto(s)
Electromiografía , Terapia por Luz de Baja Intensidad/métodos , Fibras Musculares Esqueléticas/fisiología , Fibras Musculares Esqueléticas/efectos de la radiación , Vértebras Cervicales/efectos de la radiación , Estudios Cruzados , Método Doble Ciego , Femenino , Voluntarios Sanos , Humanos , Masculino , Placebos , Adulto Joven
8.
Strahlenther Onkol ; 193(7): 589-592, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28444429

RESUMEN

Herein, the authors describe the case of a 31-year-old female patient with primary metastatic adenocarcinoma of the lung referred for radiation therapy of newly diagnosed intramedullary spinal cord metastasis at C4/5 and an adjacent osteolytic lesion. Radiotherapy of the cervical spine level C3 to C5, including the whole vertebra, was performed with 30 Gy in 10 fractions. The patient's systemic therapy with crizotinib 250 mg twice daily was continued. After 8 fractions of radiation the patient developed increasing dysphagia. Ulceration of the hypopharynx and the upper esophagus were obvious in esophagoscopy and CT. Hospitalization for analgesia and percutaneous endoscopic gastrostomy (PEG) was required. First oral intake was possible 3 weeks after the onset of symptoms. The early onset, severity, and duration of mucositis seemed highly unusual in this case. A review of the literature failed to identify any reference to increased mucositis after radiation therapy concurrent with crizotinib, although references to such an effect with other tyrosine kinase inhibitors (TKI) were found. Nevertheless, the authors presume that a considerable risk of unexpected interactions exists. When crizotinib and radiotherapy are combined, heightened attention toward intensified reactions seems to be warranted.


Asunto(s)
Adenocarcinoma/secundario , Adenocarcinoma/terapia , Vértebras Cervicales/efectos de la radiación , Quimioradioterapia/efectos adversos , Esófago/efectos de la radiación , Hipofaringe/efectos de la radiación , Neoplasias Pulmonares/terapia , Pirazoles/efectos adversos , Pirazoles/uso terapéutico , Piridinas/efectos adversos , Piridinas/uso terapéutico , Traumatismos por Radiación/etiología , Neoplasias de la Médula Espinal/secundario , Neoplasias de la Médula Espinal/terapia , Neoplasias de la Columna Vertebral/secundario , Neoplasias de la Columna Vertebral/terapia , Úlcera/etiología , Adenocarcinoma/patología , Adulto , Crizotinib , Trastornos de Deglución/etiología , Nutrición Enteral , Esofagoscopía , Femenino , Humanos , Neoplasias Pulmonares/patología , Mucositis/etiología , Mucositis/terapia , Traumatismos por Radiación/terapia , Dosificación Radioterapéutica , Neoplasias de la Médula Espinal/patología , Neoplasias de la Columna Vertebral/patología , Tomografía Computarizada por Rayos X
10.
Oncotarget ; 7(29): 46662-46667, 2016 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-27259242

RESUMEN

PURPOSE: The aim of this study is to determine the inter-fractional motion of cervical spine in radiotherapy (RT). MATERIALS AND METHODS: Eleven localized head and neck cancer patients who were treated from April 2014 to September 2015 were evaluated. Every patient underwent 3 times of computed tomography (CT) simulation with equivalent setting. Left-right (LR, x) and antero-posterior (AP, z) directional shift of cervical spine were evaluated using 33 number of CT image. In regard to random error, geometric changes were evaluated by 22 data set (compared the first obtained CT to second or third CT) by one-sample T test. Systemic error was evaluated by each patients' data set (11 pairs) by paired T test. RESULTS: The mean random error of LR and AP translational shift of cervical spine were -0.39 ± 3.24 mm and -0.57 ± 0.99 mm respectively. The mean random error of translational change of AP direction showed statistical significance (p = 0.014). The mean random error of x and z rotational shift were -0.07 ± 0.29° and -0.05 ± 0.35°, respectively. The mean systemic error of translational shift of LR and AP direction were -0.64 ± 2.57 mm and -0.33 ± 1.22 mm, respectively. The mean systemic error of rotational shift of x and z were 0.01 ± 0.18° and -0.27 ± 0.33°, respectively. The mean systemic error of rotational changes of z direction showed statistical difference (p = 0.022). CONCLUSIONS: We have to be aware of the inter-fractional motion of cervical spine in head and neck RT and give enough margins in RT planning.


Asunto(s)
Neoplasias de Cabeza y Cuello/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Adulto , Anciano , Anciano de 80 o más Años , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/efectos de la radiación , Fraccionamiento de la Dosis de Radiación , Femenino , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Movimientos de los Órganos , Tomografía Computarizada por Rayos X , Incertidumbre
11.
Br J Radiol ; 89(1060): 20150635, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26838951

RESUMEN

OBJECTIVE: This study evaluated the potential benefit of a split-parotid delineation approach on the parotid gland in the treatment planning of patients with nasopharyngeal carcinoma (NPC). METHODS: 50 patients with NPC with parapharyngeal space (PPS) and/or level IIa cervical node involvements were divided into three groups: PPS only, level IIa cervical node only and both. Two volumetric-modulated arc therapy plans were computed. The first plan (control) was generated based on the routine treatment-planning protocol, while the second plan (test) was computed with the split-parotid delineation approach, in which a line through the anterolateral margin of the retromandibular vein was created that divided the parotid gland into anterolateral and posteromedial subsegments. For the test plan, the anterolateral subsegment was prescribed, with a dose constraint of 25 Gy in the plan optimization. Dosimetric data of the parotid gland, target volumes and selected organs at risk (OARs) were compared between the control and test plans. RESULTS: The mean dose to the anterolateral subsegment of the parotid gland in all three groups was kept below 25 Gy. The test plan demonstrated significantly lower mean parotid dose than the control plan in the entire gland and the anterolateral subsegment in all three groups. The difference was the greatest in Group 3. CONCLUSION: The split-parotid delineation approach significantly lowered the mean dose to the anterolateral subsegment and overall gland without greatly compromising the doses to target volumes and other OARs. The effect was more obvious for both PPS and level IIa cervical node involvements than for either of them alone. ADVANCES IN KNOWLEDGE: It is the first article based on the assumption that parotid gland stem cells are situated at the anterolateral segment of the gland, and applied the split-parotid delineation approach to the parotid gland in the treatment planning of patients with NPC with PPS and level IIa cervical node involvements, so that the function of the post-radiotherapy parotid gland might be better preserved.


Asunto(s)
Neoplasias Nasofaríngeas/radioterapia , Glándula Parótida/efectos de la radiación , Adulto , Anciano , Carcinoma , Vértebras Cervicales/efectos de la radiación , Femenino , Humanos , Metástasis Linfática , Masculino , Persona de Mediana Edad , Carcinoma Nasofaríngeo , Cuello , Invasividad Neoplásica , Órganos en Riesgo , Radiometría , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Tomografía Computarizada por Rayos X
12.
Eur Radiol ; 26(4): 979-85, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26201294

RESUMEN

OBJECTIVE: To perform an internal audit at a university hospital with the aim of evaluating the number, clinical indication and operating procedure of computed tomography (CT) performed on pregnant patients and of estimating the radiation doses to the conceptus. METHODS: A retrospective review was conducted of all CT examinations performed in a single centre on pregnant patients between January 2008 and July 2013. The radiation doses to the conceptus were estimated. The results were compared with published data. RESULTS: The number of CT examinations during pregnancy increased from 3-4 per year in 2008-2011 to 11 per year in 2012. The mean estimated conceptus radiation dose was considered negligible for CT of the head and cervical spine, being less than 0.01 mGy, and for CT of the chest, less than 0.1 mGy. The estimated conceptus radiation dose from abdominopelvic CT was on average 28.7 mGy (range 6.7-60.5 mGy). CONCLUSIONS: The number of CT scans of pregnant patients increased threefold during the last few years. Most clinical indications and doses were in line with good clinical practice and literature; only in two cases the dose to the conceptus was higher than 50 mGy. KEY POINTS: • An increase in CT imaging of pregnant patients is of concern. • Clinical indications were in line with good practice. • Estimated conceptus doses were lower or similar to published data. • Internal guidelines for appropriate use of imaging during pregnancy should be established.


Asunto(s)
Feto/efectos de la radiación , Adulto , Vértebras Cervicales/efectos de la radiación , Femenino , Edad Gestacional , Humanos , Persona de Mediana Edad , Embarazo , Diagnóstico Prenatal/efectos adversos , Dosis de Radiación , Radiografía Torácica/efectos adversos , Estudios Retrospectivos , Tórax/efectos de la radiación , Tomografía Computarizada por Rayos X/efectos adversos , Tomografía Computarizada por Rayos X/métodos , Adulto Joven
13.
Med Phys ; 42(12): 6955-63, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26632051

RESUMEN

PURPOSE: Radiation treatments have become increasingly more complex with the development of volumetric modulated arc therapy (VMAT) and the use of stereotactic body radiation therapy (SBRT). SBRT involves the delivery of substantially larger doses over fewer fractions than conventional therapy. SBRT-VMAT treatments will strongly benefit from in vivo patient dose verification, as any errors in delivery can be more detrimental to the radiobiology of the patient as compared to conventional therapy. Electronic portal imaging devices (EPIDs) are available on most commercial linear accelerators (Linacs) and their documented use for dosimetry makes them valuable tools for patient dose verification. In this work, the authors customize and validate a physics-based model which utilizes on-treatment EPID images to reconstruct the 3D dose delivered to the patient during SBRT-VMAT delivery. METHODS: The SBRT Linac head, including jaws, multileaf collimators, and flattening filter, were modeled using Monte Carlo methods and verified with measured data. The simulation provides energy spectrum data that are used by their "forward" model to then accurately predict fluence generated by a SBRT beam at a plane above the patient. This fluence is then transported through the patient and then the dose to the phosphor layer in the EPID is calculated. Their "inverse" model back-projects the EPID measured focal fluence to a plane upstream of the patient and recombines it with the extra-focal fluence predicted by the forward model. This estimate of total delivered fluence is then forward projected onto the patient's density matrix and a collapsed cone convolution algorithm calculates the dose delivered to the patient. The model was tested by reconstructing the dose for two prostate, three lung, and two spine SBRT-VMAT treatment fractions delivered to an anthropomorphic phantom. It was further validated against actual patient data for a lung and spine SBRT-VMAT plan. The results were verified with the treatment planning system (TPS) (ECLIPSE AAA) dose calculation. RESULTS: The SBRT-VMAT reconstruction model performed very well when compared to the TPS. A stringent 2%/2 mm χ-comparison calculation gave pass rates better than 91% for the prostate plans, 88% for the lung plans, and 86% for the spine plans for voxels containing 80% or more of the prescribed dose. Patient data were 86% for the lung and 95% for the spine. A 3%/3 mm χ-comparison was also performed and gave pass rates better than 93% for all plan types. CONCLUSIONS: The authors have customized and validated a robust, physics-based model that calculates the delivered dose to a patient for SBRT-VMAT delivery using on-treatment EPID images. The accuracy of the results indicates that this approach is suitable for clinical implementation. Future work will incorporate this model into both offline and real-time clinical adaptive radiotherapy.


Asunto(s)
Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Algoritmos , Vértebras Cervicales/efectos de la radiación , Simulación por Computador , Humanos , Pulmón/efectos de la radiación , Pulmón/cirugía , Masculino , Modelos Teóricos , Método de Montecarlo , Fantasmas de Imagen , Próstata/efectos de la radiación , Radiometría/instrumentación , Radiometría/métodos , Radiocirugia/instrumentación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/instrumentación , Radioterapia de Intensidad Modulada/instrumentación , Recto/efectos de la radiación , Tomografía Computarizada por Rayos X
14.
Int J Radiat Oncol Biol Phys ; 90(1): 155-63, 2014 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-25015207

RESUMEN

PURPOSE: To quantify changes in bone marrow fat fraction and determine associations with peripheral blood cell counts. METHODS AND MATERIALS: In this prospective study, 19 patients received either highly myelotoxic treatment (radiation therapy plus cisplatin, 5-fluorouracil mitomycin C [FU/MMC], or cisplatin/5-FU/cetuximab) or less myelotoxic treatment (capecitabine-radiation therapy or no concurrent chemotherapy). Patients underwent MR imaging and venipuncture at baseline, midtreatment, and posttreatment visits. We performed mixed effects modeling of the mean proton density fat fraction (PDFF[%]) by linear time, treatment, and vertebral column region (lumbar [L]4-sacral [S]2 vs thoracic [T]10-L3 vs cervical[C]3-T9), while controlling for cumulative mean dose and other confounders. Spearman rank correlations were performed by white blood cell (WBC) counts versus the differences in PDFF(%) before and after treatment. RESULTS: Cumulative mean dose was associated with a 0.43% per Gy (P=.004) increase in PDFF(%). In the highly myelotoxic group, we observed significant changes in PDFF(%) per visit within L4-S2 (10.1%, P<.001) and within T10-L3 (3.93%, P=.01), relative to the reference C3-T9. In the less myelotoxic group, we did not observe significant changes in PDFF(%) per visit according to region. Within L4-S2, we observed a significant difference between treatment groups in the change in PDFF(%) per visit (5.36%, P=.04). Rank correlations of the inverse log differences in WBC versus the differences in PDFF(%) overall and within T10-S2 ranged from 0.69 to 0.78 (P<.05). Rank correlations of the inverse log differences in absolute neutrophil counts versus the differences in PDFF(%) overall and within L4-S2 ranged from 0.79 to 0.81 (P<.05). CONCLUSIONS: Magnetic resonance imaging fat quantification is sensitive to marrow composition changes that result from chemoradiation therapy. These changes are associated with peripheral blood cell counts. This study supports a rationale for bone marrow-sparing treatment planning to reduce the risk of hematologic toxicity.


Asunto(s)
Tejido Adiposo/efectos de los fármacos , Tejido Adiposo/efectos de la radiación , Médula Ósea/efectos de los fármacos , Médula Ósea/efectos de la radiación , Quimioradioterapia/efectos adversos , Fluorouracilo/administración & dosificación , Columna Vertebral/efectos de los fármacos , Columna Vertebral/efectos de la radiación , Tejido Adiposo/anatomía & histología , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Monoclonales Humanizados/administración & dosificación , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Neoplasias del Ano/terapia , Recuento de Células Sanguíneas , Médula Ósea/anatomía & histología , Células de la Médula Ósea/efectos de los fármacos , Células de la Médula Ósea/efectos de la radiación , Capecitabina , Vértebras Cervicales/anatomía & histología , Vértebras Cervicales/efectos de los fármacos , Vértebras Cervicales/efectos de la radiación , Cetuximab , Quimioradioterapia/métodos , Cisplatino/administración & dosificación , Desoxicitidina/administración & dosificación , Desoxicitidina/análogos & derivados , Neoplasias Endometriales/terapia , Femenino , Fluorouracilo/análogos & derivados , Humanos , Vértebras Lumbares/anatomía & histología , Vértebras Lumbares/efectos de los fármacos , Vértebras Lumbares/efectos de la radiación , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Mitomicina/administración & dosificación , Paclitaxel/administración & dosificación , Estudios Prospectivos , Neoplasias de la Próstata/terapia , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/efectos adversos , Neoplasias del Recto/terapia , Columna Vertebral/anatomía & histología , Vértebras Torácicas/anatomía & histología , Vértebras Torácicas/efectos de los fármacos , Vértebras Torácicas/efectos de la radiación , Neoplasias del Cuello Uterino/terapia
15.
Dentomaxillofac Radiol ; 43(6): 20130419, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24834483

RESUMEN

OBJECTIVES: When bitewing radiographs are not possible (e.g. patients with special needs), oblique lateral radiographs may offer an alternative. The aims of this study were to assess the impact of horizontal projection angulation, focus-to-skin distance, exposure time and age of the patient on the equivalent radiation dose of several organs in the head and neck region by means of personal computer X-ray Monte Carlo (PCXMC) calculations and to assess the dose obtained from conventional bitewing radiographs. METHODS: PCXMC v. 2.0 software (STUK(®), Helsinki, Finland) was used to estimate the equivalent radiation doses and the total effective dose. Three exposure times, five age categories, two focus-to-skin distances and eight horizontal geometric angulations were assumed. The organs involved were the thyroid gland, oesophagus, salivary glands, bone marrow, oral mucosa, skull, cervical spine and skin. A similar calculation was also performed for bitewings taken with a rectangular collimator. Results and conclusion Bitewings taken with rectangular collimation decrease the radiation burden of the patient to 50%, compared with circular collimation. In the oblique lateral radiographs, focus-to-skin distance, patient's age and beam collimation had a significant impact on the equivalent doses measured in this study. Exposure time had a significant impact on the equivalent doses of the salivary glands, oral mucosa, skull and skin. Horizontal angulations had a significant impact on the equivalent doses of the thyroid gland, bone marrow, oral mucosa, skull and cervical spine. The total effective radiation dose was significantly influenced by all parameters investigated in this study.


Asunto(s)
Cabeza/efectos de la radiación , Cuello/efectos de la radiación , Dosis de Radiación , Radiografía de Mordida Lateral/estadística & datos numéricos , Radiografía Dental/estadística & datos numéricos , Adolescente , Adulto , Factores de Edad , Médula Ósea/efectos de la radiación , Vértebras Cervicales/efectos de la radiación , Niño , Preescolar , Esófago/efectos de la radiación , Humanos , Lactante , Método de Montecarlo , Mucosa Bucal/efectos de la radiación , Radiografía de Mordida Lateral/métodos , Radiografía Dental/métodos , Glándulas Salivales/efectos de la radiación , Piel/efectos de la radiación , Cráneo/efectos de la radiación , Programas Informáticos , Glándula Tiroides/efectos de la radiación , Factores de Tiempo
16.
BMC Res Notes ; 6: 494, 2013 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-24289190

RESUMEN

BACKGROUND: Paragangliomas of the head and neck are rare tumors. Moreover, malignant paragangliomas of the cervical spine are extremely rare. Currently, the combination of curative surgical resection and secondary adjuvant radiotherapy is the gold standard for treating symptomatic malignant paragangliomas. However, traditional treatments for malignant paraganglioma remain unsuccessful. The purpose of this study is to report an exceedingly rare case involving cervical metastasis of a malignant paraganglioma. CASE PRESENTATION: In this case report, we present a case involving a 72-year-old male with a history of paraganglioma of the neck. He had been experiencing bilateral shoulder pain, neck pain and weakness in the upper extremities for more than six months. Magnetic resonance imaging of the cervical spine revealed a metastasis at C4 with severe vertebral body destruction. To avoid serious complications associated with surgical resection, CyberKnife® radiosurgery (Accuray, Inc., Sunnyvale, CA, USA) was performed on the parapharyngeal and cervical lesions. A secondary surgery, which involved a posterior laminectomy at C3-6 and posterior fusion at C1-T1, was performed two weeks after the radiosurgery. A histological examination of the surgical specimen demonstrated a malignant paraganglioma. The patient regained strength in all extremities in the postoperative field, and his pain was dramatically reduced. A magnetic resonance imaging study performed three months after the surgery showed a reduced tumor size and spinal cord decompression. CONCLUSION: This case study is the first report of a patient with symptomatic cervical metastasis of a malignant paraganglioma treated with a combination of radiosurgery and posterior spinal surgery. Although the optimal treatment for these conditions remains unclear, concomitant treatment with radiosurgery and reconstructive surgery appeared to be both safe and effective in this challenging case.


Asunto(s)
Neoplasias Óseas/cirugía , Vértebras Cervicales/cirugía , Neoplasias de Cabeza y Cuello/cirugía , Paraganglioma/cirugía , Anciano , Neoplasias Óseas/radioterapia , Neoplasias Óseas/secundario , Vértebras Cervicales/patología , Vértebras Cervicales/efectos de la radiación , Cervicoplastia , Terapia Combinada , Neoplasias de Cabeza y Cuello/patología , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Masculino , Paraganglioma/radioterapia , Paraganglioma/secundario , Resultado del Tratamiento
17.
Spine (Phila Pa 1976) ; 38(21): E1348-56, 2013 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-23823573

RESUMEN

STUDY DESIGN: Retrospective study of 904 patients with a diagnosis of atlantoaxial dislocation (AAD), using a novel surgical classification and treatment strategy. OBJECTIVE: To describe a novel surgical classification and treatment strategy for AADs. SUMMARY OF BACKGROUND DATA: AADs can result from a variety of etiologies, yet no comprehensive classification has been accepted that guides treatment. Because of the rarity of the cases, however, the treatment strategy has also been debated. METHODS: During a period of 12 years, a total of 904 patients with a diagnosis of AAD were recruited from a single academic institution. According to the treatment algorithm that included preoperative evaluation using dynamic radiograph, reconstructive computed tomography, and skeletal traction test, the cases were classified into 4 types: I to IV. Types I and II were fused in the reduced position from a posterior approach. Type III, which were irreducible dislocations, were converted to reducible dislocations using a transoral atlantoaxial release, followed by a posterior fusion. Type IV presented with bony dislocations and required transoral osseous decompressions prior to posterior fusion. RESULTS: Four hundred seventy-two cases were classified as type I, 160 as type II, 268 as type III, and 4 cases as type IV. Follow-up was in the range of 2 to 12 years (average: 60.5 mo). Eight hundred and ninety-nine cases (99.4%) achieved a solid atlantoaxial fusion. Anatomic atlantoaxial reduction was achieved in 892 cases (98.7%), whereas 12 cases had a partial reduction. Neurological improvement was seen in 84.1% (512/609) of the patients with myelopathy. The overall complication rate was 9.1% (82/949). CONCLUSION: Our surgical classification and treatment strategy for AADs was applied in those 904 cases and associated with excellent clinical results with a minimal risk of complications. LEVEL OF EVIDENCE: 4.


Asunto(s)
Articulación Atlantoaxoidea/cirugía , Luxaciones Articulares/clasificación , Luxaciones Articulares/cirugía , Procedimientos Ortopédicos/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Articulación Atlantoaxoidea/diagnóstico por imagen , Vértebras Cervicales/efectos de la radiación , Vértebras Cervicales/cirugía , Niño , Preescolar , Femenino , Humanos , Luxaciones Articulares/diagnóstico , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Procedimientos Ortopédicos/instrumentación , Evaluación de Resultado en la Atención de Salud , Reproducibilidad de los Resultados , Estudios Retrospectivos , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Tomografía Computarizada por Rayos X , Tracción/métodos , Adulto Joven
18.
J Med Imaging Radiat Oncol ; 57(4): 503-11, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23870352

RESUMEN

INTRODUCTION: The study aims to establish the optimal planning risk volume (PRV) to the spinal cord (SC) for oropharyngeal cancer patients during adaptive radiation therapy with concurrent chemotherapy. METHODS: Geometrical uncertainties of the SC were evaluated. Differences between planned and delivered maximum doses to each part of the SC were established for every fraction dose and for cumulative dose. Maximum doses were evaluated as a dose received in 0.5 and 1 cm(3) of the analysed part of the SC defined as C1-C2, C3-C4, C5-C6 and C7-Th1 where Cn was a n-th cervical vertebra (n = 1, … , 7) and Th1 was the first thoracic vertebra. Finally, relations between dose differences and geometrical uncertainties were analysed using a relative risk (RR) and the importance of the PRV dose gradient to establish an optimal PRV for the SC. RESULTS: Prospective study based on the 875 observations from 25 oropharyngeal cancer patients was performed. The C1-C2 part of the SC is most exposed to risk of overdosage during chemoradiation for patients with oropharyngeal cancer due to its proximity to the clinical target volume (CTV). Doses received by other parts of the SC are smaller, with the lowest dose delivered to C7-Th1. For the C1-C2, delivered dose was higher than planned dose by 11%, while for the C7-Th1, this difference was smaller than 7%. The lowest movement of individual parts of the SC were detected for the C1-C2 and the highest for the C7-Th1. The standard deviations of the mean shift ranged respectively from 0.9 to 1.4 mm and from 1.3 to 2.9 mm. For each part of the SC delivered dose was smaller than planned dose to the PRV (RR < 1). CONCLUSION: Our study showed that for chemoradiation of oropharyngeal cancer, using daily image guidance and proper plan adaptation scheme, the current PRV margin for the SC could be reduced to 4 mm.


Asunto(s)
Neoplasias Orofaríngeas/radioterapia , Posicionamiento del Paciente/métodos , Protección Radiológica/métodos , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Médula Espinal/efectos de la radiación , Vértebras Cervicales/efectos de la radiación , Humanos , Inmovilización/métodos , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Am J Orthod Dentofacial Orthop ; 143(6): 784-92, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23726328

RESUMEN

INTRODUCTION: With the advent of cone-beam computed tomography (CBCT) scans, there has been a transition toward these scans' replacing traditional radiographs for orthodontic diagnosis and treatment planning. Children represent a significant proportion of orthodontic patients. Similar CBCT exposure settings are predicted to result in higher equivalent doses to the head and neck organs in children than in adults. The purpose of this study was to measure the difference in equivalent organ doses from different scanners under similar settings in children compared with adults. METHODS: Two phantom heads were used, representing a 33-year-old woman and a 5-year-old boy. Optically stimulated dosimeters were placed at 8 key head and neck organs, and equivalent doses to these organs were calculated after scanning. The manufacturers' predefined exposure settings were used. RESULTS: One scanner had a pediatric preset option; the other did not. Scanning the child's phantom head with the adult settings resulted in significantly higher equivalent radiation doses to children compared with adults, ranging from a 117% average ratio of equivalent dose to 341%. Readings at the cervical spine level were decreased significantly, down to 30% of the adult equivalent dose. When the pediatric preset was used for the scans, there was a decrease in the ratio of equivalent dose to the child mandible and thyroid. CONCLUSIONS: CBCT scans with adult settings on both phantom heads resulted in higher radiation doses to the head and neck organs in the child compared with the adult. In practice, this might result in excessive radiation to children scanned with default adult settings. Collimation should be used when possible to reduce the radiation dose to the patient. While CBCT scans offer a valuable tool, use of CBCT scans should be justified on a specific case-by-case basis.


Asunto(s)
Tomografía Computarizada de Haz Cónico/instrumentación , Cabeza/efectos de la radiación , Cuello/efectos de la radiación , Dosis de Radiación , Adulto , Encéfalo/efectos de la radiación , Vértebras Cervicales/efectos de la radiación , Preescolar , Ojo/efectos de la radiación , Femenino , Humanos , Cristalino/efectos de la radiación , Masculino , Mandíbula/efectos de la radiación , Maxilar/efectos de la radiación , Glándula Parótida/efectos de la radiación , Fantasmas de Imagen , Radiometría/instrumentación , Cráneo/efectos de la radiación , Glándula Tiroides/efectos de la radiación
20.
Dentomaxillofac Radiol ; 42(7): 20120417, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23584925

RESUMEN

OBJECTIVES: Evaluation and reduction of dose are important issues. Since cone beam CT (CBCT) has been established now not just in dentistry, the number of acquired examinations continues to rise. Unfortunately, it is very difficult to compare the doses of available devices on the market owing to different exposition parameters, volumes and geometries. The aim of this study was to evaluate the spans of effective doses (EDs) of ten different CBCT devices. METHODS: 48 thermoluminescent dosemeters were placed in 24 sites in a RANDO(®) head phantom. Protocols with lowest exposition parameters and protocols with highest exposition parameters were performed for each of the ten devices. The ED was calculated from the measured energy doses according to the International Commission on Radiological Protection 2007 recommendations for each protocol and device, and the statistical values were evaluated afterwards. RESULTS: The calculation of the ED resulted in values between 17.2 µSv and 396 µSv for the ten devices. The mean values for protocols with lowest and highest exposition parameters were 31.6 µSv and 209 µSv, respectively. CONCLUSIONS: It was not the aim of this study to evaluate the image quality depending on different exposition parameters but to define the spans of EDs in which different CBCT devices work. There is a wide span of ED for different CBCT devices depending on the selected exposition parameters, required spatial resolution and many other factors.


Asunto(s)
Tomografía Computarizada de Haz Cónico/instrumentación , Dosis de Radiación , Calibración , Vértebras Cervicales/efectos de la radiación , Mejilla/efectos de la radiación , Tomografía Computarizada de Haz Cónico/métodos , Esófago/efectos de la radiación , Cabeza/efectos de la radiación , Humanos , Cristalino/efectos de la radiación , Mandíbula/efectos de la radiación , Mesencéfalo/efectos de la radiación , Órbita/efectos de la radiación , Glándula Parótida , Fantasmas de Imagen , Hipófisis/efectos de la radiación , Base del Cráneo/efectos de la radiación , Glándula Sublingual/efectos de la radiación , Glándula Submandibular/efectos de la radiación , Dosimetría Termoluminiscente/instrumentación , Glándula Tiroides/efectos de la radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...