Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 2.241
1.
Eur J Med Res ; 29(1): 268, 2024 May 03.
Article En | MEDLINE | ID: mdl-38702744

RATIONALE AND OBJECTIVES: Bleeding is a major complication of transbronchial lung cryobiopsy (TBLC), and pre-placing a bronchial balloon is one of the clinical practices used to prevent it, but with very weak evidence, which should be confirmed. This study aimed to conduct whether pre-placing a bronchial balloon in TBLC for diagnosing interstitial lung disease (ILD) is more safety. MATERIALS AND METHODS: In this prospective, single-center, randomized controlled trial, patients with suspected ILD were enrolled and randomly assigned to pre-placed balloon and none-pre-placed balloon groups. The primary outcome was incidence of moderate bleeding in each group. The secondary endpoints were the incidence of severe bleeding, pneumothorax, and other procedural complications. RESULTS: Exactly 250 patients were enrolled between August 2019 and March 2022, with 125 in each group. There were no significant differences in severe bleeding between the none-pre-placed balloon group and pre-placed balloon group (1.6% vs. 0.8%; adjusted p = 0.520), while more moderate bleeding occurred in the none-pre-placed balloon group (26.4% vs. 6.4%, adjusted p = 0.001), as well as more use of hemostatic drug (28.0% vs. 6.4%, adjusted p = 0.001). Three patients in the none-pre-placed balloon group used the bronchial balloon. More samples could be acquired in the pre-placed balloon group than in the none-pre-placed balloon group (3.8 ± 0.9 vs. 3.1 ± 0.9, p < 0.001). There were no significant differences in multidisciplinary discussion (MDD) between the two groups (89.6% vs. 91.2%, adjusted p = 0.182). CONCLUSION: A pre-placed bronchial balloon can reduce the incidence of moderate bleeding and increase the confidence of the bronchoscopists. However, it had no effect on increasing the diagnostic rate of MDD and reducing severe bleeding. REGISTRATION NUMBER: NCT04047667 ( www. CLINICALTRIALS: gov identifier).


Bronchoscopy , Cryosurgery , Lung Diseases, Interstitial , Humans , Male , Female , Lung Diseases, Interstitial/diagnosis , Lung Diseases, Interstitial/pathology , Middle Aged , Aged , Prospective Studies , Bronchoscopy/methods , Bronchoscopy/adverse effects , Cryosurgery/methods , Cryosurgery/adverse effects , Biopsy/methods , Biopsy/adverse effects , Hemorrhage/etiology , Hemorrhage/diagnosis , Hemorrhage/prevention & control , Lung/pathology , Bronchi/pathology
2.
Europace ; 26(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38624037

AIMS: Pulmonary vein isolation using cryoablation is effective and safe in patients with atrial fibrillation (AF). Although both obesity and underweight are associated with a higher risk for incident AF, there is limited data on the efficacy and safety following cryoablation according to body mass index (BMI) especially in Asians. METHODS AND RESULTS: Using the Korean Heart Rhythm Society Cryoablation registry, a multicentre registry of 12 tertiary hospitals, we analysed AF recurrence and procedure-related complications after cryoablation by BMI (kg/m2) groups (BMI < 18.5, underweight, UW; 18.5-23, normal, NW; 23-25, overweight, OW; 25-30, obese Ⅰ, OⅠ; ≥30, obese Ⅱ, OⅡ). A total of 2648 patients were included (median age 62.0 years; 76.7% men; 55.6% non-paroxysmal AF). Patients were categorized by BMI groups: 0.9% UW, 18.7% NW, 24.8% OW, 46.1% OI, and 9.4% OII. Underweight patients were the oldest and had least percentage of non-paroxysmal AF (33.3%). During a median follow-up of 1.7 years, atrial arrhythmia recurred in 874 (33.0%) patients (incidence rate, 18.9 per 100 person-years). After multivariable adjustment, the risk of AF recurrence was higher in UW group compared with NW group (adjusted hazard ratio, 95% confidence interval; 2.55, 1.18-5.50, P = 0.02). Procedure-related complications occurred in 123 (4.7%) patients, and the risk was higher for UW patients (odds ratio, 95% confidence interval; 2.90, 0.94-8.99, P = 0.07), mainly due to transient phrenic nerve palsy. CONCLUSION: Underweight patients showed a higher risk of AF recurrence after cryoablation compared with NW patients. Also, careful attention is needed on the occurrence of phrenic nerve palsy in UW patients.


Atrial Fibrillation , Body Mass Index , Cryosurgery , Obesity , Pulmonary Veins , Recurrence , Registries , Humans , Atrial Fibrillation/surgery , Cryosurgery/adverse effects , Male , Female , Middle Aged , Republic of Korea/epidemiology , Aged , Treatment Outcome , Risk Factors , Pulmonary Veins/surgery , Obesity/complications , Thinness/complications , Time Factors , Postoperative Complications/epidemiology , Postoperative Complications/etiology
3.
Europace ; 26(4)2024 Mar 30.
Article En | MEDLINE | ID: mdl-38588039

AIMS: Phrenic nerve injury (PNI) is the most common complication during cryoballoon ablation. Currently, two cryoballoon systems are available, yet the difference is unclear. We sought to compare the acute procedural efficacy and safety of the two cryoballoons. METHODS: This prospective observational study consisted of 2,555 consecutive atrial fibrillation (AF) patients undergoing pulmonary vein isolation (PVI) using either conventional (Arctic Front Advance) (AFA-CB) or novel cryoballoons (POLARx) (POLARx-CB) at 19 centers between January 2022 and October 2023. RESULTS: Among 2,555 patients (68.8 ± 10.9 years, 1,740 men, paroxysmal AF[PAF] 1,670 patients), PVIs were performed by the AFA-CB and POLARx-CB in 1,358 and 1,197 patients, respectively. Touch-up ablation was required in 299(11.7%) patients. The touch-up rate was significantly lower for POLARx-CB than AFA-CB (9.5% vs. 13.6%, p = 0.002), especially for right inferior PVs (RIPVs). The touch-up rate was significantly lower for PAF than non-PAF (8.8% vs. 17.2%, P < 0.001) and was similar between the two cryoballoons in non-PAF patients. Right PNI occurred in 64(2.5%) patients and 22(0.9%) were symptomatic. It occurred during the right superior PV (RSPV) ablation in 39(1.5%) patients. The incidence was significantly higher for POLARx-CB than AFA-CB (3.8% vs. 1.3%, P < 0.001) as was the incidence of symptomatic PNI (1.7% vs. 0.1%, P < 0.001). The difference was significant during RSPV (2.5% vs. 0.7%, P < 0.001) but not RIPV ablation. The PNI recovered more quickly for the AFA-CB than POLARx-CB. CONCLUSIONS: Our study demonstrated a significantly higher incidence of right PNI and lower touch-up rate for the POLARx-CB than AFA-CB in the real-world clinical practice.


Atrial Fibrillation , Cryosurgery , Peripheral Nerve Injuries , Phrenic Nerve , Pulmonary Veins , Registries , Humans , Phrenic Nerve/injuries , Male , Female , Atrial Fibrillation/surgery , Atrial Fibrillation/epidemiology , Pulmonary Veins/surgery , Aged , Cryosurgery/adverse effects , Cryosurgery/methods , Prospective Studies , Incidence , Peripheral Nerve Injuries/etiology , Peripheral Nerve Injuries/epidemiology , Peripheral Nerve Injuries/prevention & control , Middle Aged , Treatment Outcome , Catheter Ablation/adverse effects
4.
Europace ; 26(4)2024 Mar 30.
Article En | MEDLINE | ID: mdl-38582974

AIMS: The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS: This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION: In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION: NCT04893317.


Cardiomyopathies , Catheter Ablation , Cryosurgery , Tachycardia, Ventricular , Aged , Humans , Middle Aged , Cardiomyopathies/complications , Cardiomyopathies/diagnosis , Cardiomyopathies/surgery , Catheter Ablation/adverse effects , Cicatrix/complications , Cryosurgery/adverse effects , Prospective Studies , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/surgery , Temperature , Treatment Outcome
5.
Europace ; 26(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38637325

AIMS: Left atrial appendage electrical isolation (LAAEI) has demonstrated a significant enhancement in the success rate of atrial fibrillation (AF) ablation. Nevertheless, concerns persist about the safety of LAAEI, particularly regarding alterations in left atrial appendage (LAA) flow velocity and the potential risks of thrombus. This study aimed to assess the efficacy and safety of LAAEI, investigating changes in LAA flow velocity in canines. METHODS AND RESULTS: The study comprised a total of 10 canines. The LAAEI procedure used by a 23 mm cryoballoon of the second generation was conducted at least 180 s. Intracardiac ultrasonography (ICE) was employed to quantify the velocity flow of the LAA both prior to and following LAAEI. Following a 3-month period, subsequent evaluations were performed to assess the LAA velocity flow and the potential reconnection. Histopathological examination was conducted. Left atrial appendage electrical isolation was effectively accomplished in all canines, resulting in a 100% acute success rate (10/10). The flow velocity in the LAA showed a notable reduction during LAAEI as compared with the values before the ablation procedure (53.12 ± 5.89 vs. 42.01 ± 9.22 cm/s, P = 0.007). After the follow-up, reconnection was observed in four canines, leading to a success rate of LAAEI of 60% (6/10). The flow velocity in the LAA was consistently lower (53.12 ± 5.89 vs. 44.33 ± 10.49 cm/s, P = 0.006), and no blood clot development was observed. The histopathological study indicated that there was consistent and complete injury to the LAA, affecting all layers of its wall. The injured tissue was subsequently replaced by fibrous tissue. CONCLUSION: The feasibility of using cryoballoon ablation for LAAEI was confirmed in canines, leading to a significant reduction of LAA flow velocity after ablation. Some restoration of LAA flow velocity after ablation may be linked to the passive movement of the LAA and potential reconnecting. However, this conclusion is limited to animal study; more clinical data are needed to further illustrate the safety and accessibility of LAAEI in humans.


Atrial Appendage , Atrial Fibrillation , Cryosurgery , Dogs , Animals , Atrial Appendage/surgery , Cryosurgery/methods , Cryosurgery/adverse effects , Cryosurgery/instrumentation , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Equipment Design , Blood Flow Velocity , Treatment Outcome , Male
6.
S Afr Med J ; 114(3): e1338, 2024 Mar 18.
Article En | MEDLINE | ID: mdl-38525578

BACKGROUND: Pulmonary vein isolation (PVI) with cryoballoon catheter ablation (CBA) is a well-established and widely adopted method for the treatment of patients with atrial fibrillation (AF) to prevent recurrences of AF. CBA adoption in South Africa (SA) and outcome data in SA patients are limited. OBJECTIVES: To evaluate real-world usage, safety and effectiveness of CBA in SA. METHODS: In this sub-analysis of the Cryo Global Registry, 81 participants with paroxysmal AF (PAF) and persistent AF (PsAF) were enrolled between 2017 and 2021 across two private SA hospitals. Baseline characteristics, procedural characteristics, 12-month safety, effectiveness (atrial arrhythmia recurrence), healthcare utilisation (repeat ablation and all-cause hospitalisation), quality of life (QoL; measured by EQ-5D-3L) and predefined symptoms were reported on. RESULTS: Participants in the SA cohort were a mean (standard deviation) of 60 (12) years old, 19 (23.5%) were female, and 48 (59.3%) presented with PAF. The overall presence of baseline comorbidities in the SA cohort was relatively low compared with the entire Cryo Global Registry cohort. The acute PVI success rate was high (98.8%). Two serious procedure-related adverse events occurred in 2 (2.5%) participants in the SA cohort. Freedom from arrhythmia recurrence was 97.4% (95% confidence interval (CI) 83.2 - 99.6%) in PAF and 78.4% (95% CI 58.1 - 89.7%) in persistent AF (p=0.035). Kaplan-Meier estimates for freedom from repeat ablations and all-cause hospitalisations were 97.0% (95% CI 88.4 - 99.2%) and 98.5% (95% CI 90.0 - 99.8%), respectively. Participants reported significant improvement in EQ-5D-3L index score and symptoms from baseline (0.90 (0.11)) - 12 months (0.97 (0.07), p<0.001). CONCLUSION: CBA standard-of-care procedures in SA resulted in a high clinical freedom from arrhythmia recurrence, with a low risk of safety events within 12 months post ablation. In addition, participants experienced an improvement in QoL and high freedom from healthcare utilisation at 12 months. The obtained results will be important for guiding clinical decisions around CBA in SA.


Atrial Fibrillation , Catheter Ablation , Cryosurgery , Humans , Female , Child , Male , Atrial Fibrillation/surgery , Quality of Life , South Africa/epidemiology , Cryosurgery/adverse effects , Cryosurgery/methods , Prospective Studies , Registries , Catheter Ablation/adverse effects , Catheter Ablation/methods , Treatment Outcome , Recurrence
7.
J Cardiovasc Electrophysiol ; 35(4): 832-842, 2024 Apr.
Article En | MEDLINE | ID: mdl-38448797

INTRODUCTION: Cryoablation therapy for pulmonary vein isolation (PVI) to treat paroxysmal atrial fibrillation (PAF) is well established. A novel 28 mm cryoballoon system designed to operate under low pressure to safely reach a lower nadir temperature and maintain constant balloon size during cooling has not been prospectively studied in a large patient population for safety and efficacy. The FROZEN AF (NCT04133168) trial was an international multicenter, open-label, prospective, single-arm study on the safety and performance of a novel cryoballoon system for treatment of PAF. METHODS AND RESULTS: The study enrolled patients at 44 sites in 10 countries across North America, Europe, and Asia. Subjects were indicated for PVI treatment of PAF and had failed or were intolerant of one or more antiarrhythmic drugs. Procedural outcomes were defined based on the 2017 HRS consensus statement. Follow-up was performed at 7 days, 3, 6, and 12 months. Data are reported as mean ± SD or median (IQR). PVI was performed with a 28 mm cryoballoon in 325 drug refractory PAF patients. Complete PVI was achieved in 95.7% of patients. In cryoablation lesions longer than 60 s, 60.1% of PV isolations required only a single cryoballoon application. Procedure related complications included: phrenic nerve palsy [temporary 4 (1.2%), persistent 0 (0.0%)], cardiac tamponade/perforation 2 (0.6%), and air embolism 1 (0.3%). Freedom from documented atrial arrhythmia recurrence at 12 months was 79.9% (AF 82.7%, AFL 96.5%, AT 98.1%), antiarrhythmic drugs (AAD) were continued or re-initiated in 26.8% of patients after the 3-month blanking period. Additionally, an extension arm enrolled 50 pts for treatment with 28/31 mm variable size cryoballoon. A single temporary PNP occurred in this group, which resolved before discharge. Freedom from documented recurrence at 12 months in these pts was 82.0%. CONCLUSIONS: This novel cryoballoon may facilitate PVI to treat PAF, providing more options to address the variety of anatomies present in patients with PAF. This cryoballoon system proved to be safe and effective for treatment of patients with drug refractory or drug intolerant PAF.


Atrial Fibrillation , Catheter Ablation , Cryosurgery , Heart Injuries , Pulmonary Veins , Humans , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/epidemiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cryosurgery/adverse effects , Cryosurgery/methods , Heart Injuries/etiology , Prospective Studies , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
8.
J Am Heart Assoc ; 13(6): e033146, 2024 Mar 19.
Article En | MEDLINE | ID: mdl-38471838

BACKGROUND: Cryoballoon ablation is currently the gold standard technique for single-shot pulmonary vein isolation (PVI). Pulsed field ablation (PFA) has recently emerged as an interesting nonthermal alternative energy for PVI. The purpose of our study was to evaluate the safety and long-term efficacy of PVI using the pentaspline PFA catheter in comparison to cryoballoon ablation. METHODS AND RESULTS: Between January 2021 and December 2022, we included all consecutive patients of our center in whom a first PVI-only procedure was performed using PFA or cryoballoon. The choice of the energy was based on patients' preference between general anesthesia (PFA) and local anesthesia (cryoballoon). The primary end point was freedom from documented atrial arrhythmia recurrence after a 3-month blanking period. A total of 301 patients (paroxysmal atrial fibrillation in 220 patients) underwent a first PVI procedure performed using PFA (n=151) or cryoballoon (n=150). Complete short-term PVI was obtained in 144 of 150 patients (96%) in the cryoballoon group and in all patients of the PFA group (P=0.01). Procedure duration was significantly longer in the cryoballoon group. Transient and persistent phrenic nerve injuries were observed in the cryoballoon group only (13/150 and 2/150, respectively). One-year freedom from atrial arrhythmia was significantly higher in the PFA group compared with the cryoballoon group (87.9% versus 77.7%; adjusted hazard ratio, 0.53 [95% CI, 0.30-0.96]; P=0.037). CONCLUSIONS: This prospective, comparative, real-life study suggested that PFA could overcome safety limitations of cryoballoon with optimal effectiveness. Randomized controlled studies are required to further investigate the potential superiority of PFA over cryoballoon.


Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Prospective Studies , Treatment Outcome , Cryosurgery/adverse effects , Cryosurgery/methods , Catheters , Pulmonary Veins/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
9.
AJNR Am J Neuroradiol ; 45(4): 424-431, 2024 Apr 08.
Article En | MEDLINE | ID: mdl-38453412

BACKGROUND AND PURPOSE: Although the application of cryoablation to metastatic spinal tumors has been attempted, spinal cryoablation has the unique complication of cryogenic spinal cord injury. This study aimed to elucidate the conditions for the development of cryogenic spinal cord injury. MATERIALS AND METHODS: Fifteen canines were used in this study. A metal probe was inserted into the 13th thoracic vertebral body. Cryoablation was performed for 10 minutes by freezing the probe in liquid nitrogen. The control canine underwent probe insertion only. Spinal cord monitoring, epidural temperature measurement, motor function assessment, and pathologic examination of the spinal cord were performed. RESULTS: During the 10 minutes of cryoablation, the epidural temperature decreased and reached the lowest epidural temperature (LET) at the end of cryoablation. The LETs (degrees celsius [°C]) of each canine were -37, -30, -27, -8, -3, -2, 0, 1, 4, 8, 16, 18, 20, and 25, respectively. As the epidural temperature decreased, waveform amplitudes also decreased. At the end of cryoablation (10 minutes after the start of cryoablation), abnormal waves were observed in 92.9% (13/14) of canines. With epidural rewarming, the amplitude of the waveforms tended to recover. After epidural rewarming (2 hours after the start of cryoablation), abnormal waves were observed in 28.6% (4/14) of canines. The LETs (°C) of the canines with abnormal waves after epidural rewarming were -37, -30, -27, and -8. None of the canines with normal waves after epidural rewarming had any motor impairment. In contrast, all canines with remaining abnormal waves after epidural rewarming had motor impairment. In the pathologic assessment, cryogenic changes were found in canines with LETs (°C) of -37 -30, -27, -8, 0, and 1. CONCLUSIONS: This study showed that 10-minute spinal cryoablation with LETs (°C) of -37, -30, -27, -8, 0, and 1 caused cryogenic spinal cord injury. There was no evidence of cryogenic spinal cord injury in canines with LET of ≥4°C. The epidural temperature threshold for cryogenic spinal cord injury is between 1 and 4°C, suggesting that the epidural temperature should be maintained above at least 4°C to prevent cryogenic spinal cord injury.


Central Nervous System Neoplasms , Cryosurgery , Hypothermia, Induced , Spinal Cord Injuries , Spinal Cord Neoplasms , Spinal Neoplasms , Animals , Dogs , Spinal Neoplasms/pathology , Cryosurgery/adverse effects , Spinal Cord Injuries/etiology , Spinal Cord Injuries/surgery , Body Temperature , Spinal Cord/pathology , Spinal Cord Neoplasms/pathology , Central Nervous System Neoplasms/pathology
10.
Respiration ; 103(5): 275-279, 2024.
Article En | MEDLINE | ID: mdl-38471472

INTRODUCTION: The use of cryobiopsy in conjunction with robotic assisted bronchoscopy is on the rise due to the safety and increased diagnostic yield of cryobiopsy. The incorporation of 3D fluoroscopy in the procedure improves the workflow and helps confirm the accuracy of sampling of peripheral pulmonary nodules. METHODS: We describe an observational series of 12 patients comprising 14 nodules where cryobiopsy was performed during shape-sensing robot-assisted bronchoscopy cryobiopsy under general anesthesia. 3D fluoroscopy was used to confirm accurate placement of the cryoprobe. All these patients underwent a second spin with the 3D fluoroscopy either to sample a second lesion intraoperatively or to investigate suspected pneumothorax. RESULTS: The development of a pneumatocele was noted after cryobiopsy in each of the cases. The majority of these were in the upper lobe with the median size of a sampled nodule being 14 mm. The majority of patients were asymptomatic with 1 patient developing mild hemoptysis and 4 patients developing chest tightness or dyspnea. None of the patients required an intervention for the pneumatocele. CONCLUSION: The development of pneumatoceles appears to be a fairly frequent and benign occurrence following cryobiopsy, likely due to increased tissue destruction. The increased use of intraoperative 3D fluoroscopy is likely to highlight changes to the pulmonary parenchyma that were previously not known. The occurrence of pneumatoceles does not appear to adversely impact the safety or tolerability profile of cryobiopsy.


Bronchoscopy , Cryosurgery , Robotic Surgical Procedures , Humans , Bronchoscopy/methods , Bronchoscopy/adverse effects , Male , Middle Aged , Female , Aged , Fluoroscopy , Robotic Surgical Procedures/methods , Cryosurgery/methods , Cryosurgery/adverse effects , Lung Neoplasms/pathology , Lung Neoplasms/diagnosis , Biopsy/methods , Biopsy/adverse effects , Biopsy/instrumentation , Cysts/pathology , Cysts/diagnosis , Adult
11.
J Surg Res ; 296: 704-710, 2024 Apr.
Article En | MEDLINE | ID: mdl-38364698

INTRODUCTION: Intraoperative cryoablation of intercostal thoracic nerves is gaining popularity as a technique that decreases postoperative pain in thoracic surgery. Our study evaluates the efficacy and safety of cryoablation in pain management of pediatric cancer patients undergoing thoracotomy. METHODS: We reviewed cancer patients undergoing thoracotomies for pulmonary metastasis resection at our children's hospital from 2017 to 2023. Patients who received cryoablation were compared to those who did not. Our primary outcomes were self-reported postoperative pain scores (from 0 to 10) and opioid consumption, measured as oral morphine equivalent per kilogram. RESULTS: Thirty eight procedures were performed in 17 patients, of which 11 (64.7%) were males. Cryoablation was used in 14 (32.4%) procedures, while it was not in 24 (67.6%). Median age (17 y in both groups, P = 0.84) and length of surgery (300 cryoablation versus 282 no cryoablation, P = 0.65) were similar between the groups. Patients treated with cryoablation had a shorter hospital stay compared to those who did not (3.0 versus 4.5 d, respectively, P = 0.04) and received a lower total dose of opioids (2.2 oral morphine equivalent per kilogram versus 14.4, P = 0.004). No significant difference was noted in daily pain scores between the two groups (3.8 cryoablation versus 3.9 no cryoablation, P = 0.93). There was no difference in rates of readmissions between the cryoablation and no-cryoablation groups (14.3% versus 8.3%, P = 0.55). CONCLUSIONS: Our study suggests that cryoablation of the thoracic nerves during a thoracotomy is associated with reduced opiate consumption and shorter hospital stay. Cryoablation appears to be a promising technique for pain management in this patient population.


Cryosurgery , Lung Neoplasms , Metastasectomy , Male , Child , Humans , Female , Analgesics, Opioid/therapeutic use , Cryosurgery/adverse effects , Length of Stay , Retrospective Studies , Pain, Postoperative/etiology , Pain, Postoperative/prevention & control , Pain, Postoperative/drug therapy , Morphine/therapeutic use , Lung Neoplasms/surgery , Lung Neoplasms/drug therapy
12.
BMC Cardiovasc Disord ; 24(1): 111, 2024 Feb 16.
Article En | MEDLINE | ID: mdl-38365602

OBJECTIVES: The study aims to assess the effect of baseline glycated hemoglobin (HbA1c) levels on atrial fibrillation (AF) recurrence following cryoballoon ablation in patients with and without diabetes. METHODS: Consecutive AF patients receiving first cryoballoon ablation between April 2018 and April 2021 were included. AF recurrence and other clinical outcomes were recorded for a minimum of 12 months post-ablation, with regular assessments at 3, 6, and 12 months, followed by annual check-ups. The primary outcome was AF recurrence after ablation at longest follow-up. Multivariate Cox proportional hazards regression models were utilized to calculate the hazard ratio (HR) and 95% CI per standard deviation (SD) increase of baseline HbA1c level. RESULTS: 335 patients were included in the analysis. The mean age was 61.7 years, 61.8% were male. 12.8% had type 2 diabetes, and 81.7% of patients had paroxysmal AF. The median level of HbA1c was 5.3%, and the mean CHA2DS2-VASc score was 1.8. All cryoballoon ablation procedures, utilizing a 28-mm balloon, achieved successful pulmonary vein isolation. Over a median follow-up of 18 months, 105 patients (31.3%) experienced AF recurrence. In multivariate Cox proportional hazards analysis, a higher HbA1c level, persistent AF (HR 1.91, 95% CI 1.08 to 3.39, P = 0.026), alcohol consumption (HR 2.67, 95% CI 1.33 to 5.37, P = 0.006), and Nadir RSPV (HR 1.04, 95% CI 1.00 to 1.08, P = 0.005) were significant predictors of AF recurrence. Per-SD increase of HbA1c was associated with a 1.75-fold increase risk of AF recurrence (HR 1.75, 95% CI 1.39 to 2.21, P < 0.001). Subgroup analysis revealed that a higher HbA1c level was associated with a higher risk of AF recurrence in patients with and without diabetes, and in patients with paroxysmal and persistent AF. CONCLUSION: Baseline HbA1c level was an independent predictor of AF recurrence following cryoablation, both in patients with and without diabetes.


Atrial Fibrillation , Catheter Ablation , Cryosurgery , Diabetes Mellitus, Type 2 , Pulmonary Veins , Humans , Male , Middle Aged , Female , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Glycated Hemoglobin , Diabetes Mellitus, Type 2/complications , Diabetes Mellitus, Type 2/diagnosis , Treatment Outcome , Risk Factors , Cryosurgery/adverse effects , Recurrence , Catheter Ablation/adverse effects , Catheter Ablation/methods , Pulmonary Veins/surgery
14.
J Vasc Interv Radiol ; 35(4): 533-540, 2024 Apr.
Article En | MEDLINE | ID: mdl-38219902

PURPOSE: To assess the safety and technical success of percutaneous cryoablation (PCA) without pyeloperfusion in 94 patients with central renal tumors. MATERIALS AND METHODS: A retrospective review of all central renal tumors treated by PCA without pyeloperfusion was performed. Central tumors were defined as those involving the renal sinus fat on preprocedural cross-sectional imaging. Patient demographics and baseline tumor characteristics were recorded. The details of the PCA procedure, primary and secondary technical success, rates of local recurrence, adverse events (AEs), cancer-specific survival (CSS), and overall survival (OS) were compiled. RESULTS: Ninety-four patients (48 females [51%]; mean age, 68.2 years [range, 38-87 years]) with 94 central renal tumors were included. The mean maximal tumor diameter and mean RENAL nephrometry score were 37 mm (range, 15-67 mm) and 8 (range, 4-11), respectively. Primary technical success was achieved in 94% (n = 88) of procedures. Of the patients who did not achieve primary technical success, 3 underwent successful repeat PCA (secondary technical success, 97%; n = 91/94). The other 3 patients were surveilled for residual disease. Twenty-four patients (26%) required hydrodissection during PCA. Six patients (6%) experienced major AEs after PCA including hemorrhage requiring embolization (n = 3), hemorrhage requiring transfusions with admission (n = 2), and perinephric abscess necessitating drain placement (n = 1). Twenty-two patients (23%) experienced minor AEs. Nine patients (10%) experienced local recurrence during the follow-up period. OS was 94% (n = 88/94), whereas CSS was 98% (n = 92/94) during the study follow-up period (mean, 16 months [range, 1-102 months]). CONCLUSIONS: PCA of central renal tumors appears to be safe with high rates of technical success, even without the use of pyeloperfusion.


Carcinoma, Renal Cell , Cryosurgery , Kidney Neoplasms , Female , Humans , Aged , Carcinoma, Renal Cell/surgery , Cryosurgery/adverse effects , Cryosurgery/methods , Feasibility Studies , Treatment Outcome , Kidney Neoplasms/diagnostic imaging , Kidney Neoplasms/surgery , Retrospective Studies , Hemorrhage/etiology
15.
Pacing Clin Electrophysiol ; 47(3): 353-364, 2024 03.
Article En | MEDLINE | ID: mdl-38212906

INTRODUCTION: Atrioventricular nodal reentrant tachycardia (AVNRT) is the most common supraventricular tachycardia referred for ablation. Periprocedural conduction system damage was a primary concern during AVNRT ablation. This study aimed to assess the incidence of permanent atrioventricular (AV) block and the success rate associated with different types of catheters in slow pathway ablation. METHOD: A literature search was performed to identify studies that compared various techniques, including types of radiofrequency ablation (irrigated and nonirrigated) and different sizes of catheter tip cryoablation (4, 6, and 8-mm), in terms of their outcomes related to permanent atrioventricular block and success rate. To assess and rank the treatments for the different outcomes, a random-effects model of network meta-analysis, along with p-scores, was employed. RESULTS: A total of 27 studies with 5110 patients were included in the analysis. Overall success rates ranged from 89.78% to 100%. Point estimation showed 4-mm cryoablation exhibited an odds ratio of 0.649 (95%CI: 0.202-2.087) when compared to nonirrigated RFA. Similarly, 6-mm cryoablation had an odds ratio of 0.944 (95%CI: 0.307-2.905), 8-mm cryoablation had an odds ratio of 0.848 (95%CI: 0.089-8.107), and irrigated RFA had an odds ratio of 0.424 (95%CI: 0.058-3.121) compared to nonirrigated RFA. CONCLUSION: Our study found no significant difference in the incidence of permanent AV block between the types of catheters. The success rates were consistently high across all groups. These findings emphasize the potential of both RF ablation (irrigated and nonirrigated catheter) and cryoablation as viable options for the treatment of AVNRT, with similar safety and efficacy profile.


Atrioventricular Block , Catheter Ablation , Cryosurgery , Radiofrequency Ablation , Tachycardia, Atrioventricular Nodal Reentry , Humans , Cryosurgery/adverse effects , Cryosurgery/methods , Treatment Outcome , Network Meta-Analysis , Catheter Ablation/methods , Atrioventricular Block/etiology , Radiofrequency Ablation/adverse effects , Catheters/adverse effects
17.
Adv Ther ; 41(3): 932-944, 2024 Mar.
Article En | MEDLINE | ID: mdl-38185778

INTRODUCTION: Cryoballoon ablation (CBA) is a standard catheter ablation technology with demonstrated clinical effectiveness for the treatment of paroxysmal atrial fibrillation (PAF); however, it can be associated with major adverse events, including phrenic nerve paralysis. Pulsed field ablation (PFA) is a novel, minimally thermal technology with comparable effectiveness and low safety risk. This study aimed to compare the safety profiles of PFA and CBA through critical analyses of the literature and indirect treatment comparisons. METHODS: Studies were identified by searching the MEDLINE database and the Clinicaltrials.gov registry. Registered clinical trials and/or Food and Drug Administration Investigation Device Exemption (FDA IDE) studies evaluating PFA or CBA in adult patients with drug-refractory PAF between January 2008 and March 2023 were selected. Comparative safety between PFA and CBA was assessed for major and prespecified adverse events. Indirect comparisons were conducted using the proportion of patients experiencing adverse events and confirmed with single-arm meta-analyses and sensitivity analyses. RESULTS: Data were extracted from three PFA publications including a total of 497 patients and six CBA studies including a total of 1113 patients. The analysis revealed that PFA was associated with significantly lower risk of major adverse events {risk difference - 4.3% [95% confidence interval (CI) - 5.8, - 2.8]; risk ratio 0.16 [95% CI 0.07, 0.45]} and prespecified adverse events [risk difference - 2.5% (95% CI - 4.4, - 0.5); risk ratio 0.53 (95% CI 0.31, 0.96)]. Meta-analyses confirmed the lower rate of major adverse events for PFA [0.4% (95% CI 0.0, 1.3)] vs. CBA [5.6% (95% CI 2.6, 8.6)] and prespecified adverse events for PFA [2.7% (95% CI 1.2, 4.1)] vs. CBA [5.8% (95% CI 2.7, 9.0)]. Sensitivity analyses exploring heterogeneity across studies confirmed robustness of the main analyses. CONCLUSION: The findings of this study show that PFA has a more favorable safety profile than CBA, with significantly lower risks of major and prespecified adverse events. These indirect comparisons help contextualize the safety of PFA compared to CBA for the treatment of drug-refractory PAF in the absence of head-to-head studies.


Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Adult , Humans , Atrial Fibrillation/surgery , Cryosurgery/adverse effects , Pulmonary Veins/surgery , Treatment Outcome , Catheter Ablation/adverse effects , Recurrence
18.
Open Heart ; 11(1)2024 Jan 18.
Article En | MEDLINE | ID: mdl-38238026

INTRODUCTION: Three recent randomised controlled trials have demonstrated that pulmonary vein isolation as an initial rhythm control strategy with cryoablation reduces atrial arrhythmia recurrence in patients with symptomatic paroxysmal atrial fibrillation (PAF) compared with antiarrhythmic drug (AAD) therapy. The aim of this study was to evaluate the cost-effectiveness of first-line cryoablation compared with first-line AADs for treating symptomatic PAF in an English National Health Service (NHS) setting. METHODS: Individual patient-level data from 703 participants with PAF enrolled into Cryo-FIRST (Catheter Cryoablation Versus Antiarrhythmic Drug as First-Line Therapy of Paroxysmal Atrial Fibrillation), STOP AF First (Cryoballoon Catheter Ablation in an Antiarrhythmic Drug Naive Paroxysmal Atrial Fibrillation) and EARLY-AF (Early Aggressive Invasive Intervention for Atrial Fibrillation) were used to derive the parameters applied in the cost-effectiveness model (CEM). The CEM comprised a hybrid decision tree and Markov structure. The decision tree had a 1-year time horizon and was used to inform the initial health state allocation in the first cycle of the Markov model (40-year time horizon; 3-month cycle length). Health benefits were expressed in quality-adjusted life years (QALYs). Costs and benefits were discounted at 3.5% per year. Model outcomes were generated using probabilistic sensitivity analysis. RESULTS: The results estimated that cryoablation would yield more QALYs (+0.17) and higher costs (+£641) per patient over a lifetime than AADs. This produced an incremental cost-effectiveness ratio of £3783 per QALY gained. Independent of initial treatment, individuals were expected to receive ~1.2 ablations over a lifetime. There was a 45% relative reduction in time spent in AF health states for those initially treated with cryoablation. DISCUSSION: AF rhythm control with first-line cryoablation is cost effective compared with first-line AADs in an English NHS setting.


Atrial Fibrillation , Cryosurgery , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy , Atrial Fibrillation/surgery , Cost-Benefit Analysis , State Medicine , Anti-Arrhythmia Agents/adverse effects , Cryosurgery/adverse effects , Cryosurgery/methods
19.
J Vasc Interv Radiol ; 35(2): 185-197, 2024 Feb.
Article En | MEDLINE | ID: mdl-38272639

Thermal ablation modalities (cryoablation, radiofrequency ablation, and microwave ablation) have long been noted to occasionally induce a systemic antitumoral response. With the widespread use of checkpoint inhibitors, there is a significant interest in whether thermal ablation can promote immune system tumor recognition and increase checkpoint inhibitor response rates. In this review, we examine the current state of preclinical and clinical evidence examining the combination of checkpoint inhibitor therapies and thermal ablation modalities as well as discuss remaining the unanswered questions and directions for future research.


Cryosurgery , Neoplasms , Radiofrequency Ablation , Humans , Neoplasms/therapy , Immunotherapy/adverse effects , Cryosurgery/adverse effects , Radiofrequency Ablation/adverse effects , Combined Modality Therapy
20.
J Cardiovasc Electrophysiol ; 35(1): 198-205, 2024 Jan.
Article En | MEDLINE | ID: mdl-38037864

INTRODUCTION: The major limitation of the current cryoballoon (CB) system is a fixed 28 mm balloon-size. We sought to analyze real-world early experience with novel-sized adjustable CB. METHODS: This multicenter observational study included 140 consecutive atrial fibrillation patients (71 years, 94 men, 86 paroxysmal) who underwent pulmonary vein (PV) isolation using expandable diameter CB capable of ablation at 28 or 31 mm. RESULTS: Out of 544 targeted PVs, 526 (96.7%) were successfully isolated by a size-adjustable CB with a 770 [690-870] second median application dose, while the remaining 18 required touch-up ablation. Among them, 326 (62.0%) PVs were isolated by a 31 mm balloon, and the rate was significantly higher for upper than lower PVs (73.0% vs. 45.7%, p < .0001) and highest for right superior (78.5%) and lowest for right inferior (39.9%) PVs. The biophysical parameters and time to isolation were comparable between the 28 and 31 mm balloons, however, the real-time PV potential monitoring capability was significantly higher for 31 mm than 28 mm balloons for the left superior PV. The esophageal temperature reached 15°C during left inferior PV ablation significantly more often with 31 mm than 28 mm balloons (43.1% vs. 18.2%, p = .008). Right phrenic nerve injury (PNI) occurred in 9 (6.4%) patients during applications (6 right superior, 2 right inferior PVs), and most occurred with a 31 mm balloon. CONCLUSIONS: Our real-world early data demonstrated high acute efficacy and safety of the novel-sized adjustable CB. The biophysical parameters were similar between the 28 and 31 mm balloons. No marked decrease in the incidence of PNI was observed even with 31 mm balloons.


Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Male , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/epidemiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cryosurgery/adverse effects , Cryosurgery/methods , Pulmonary Veins/surgery , Treatment Outcome , Female
...