Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
1.
J Echocardiogr ; 18(3): 149-159, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32239383

RESUMEN

This review focused on right ventricular (RV) three-dimensional echocardiography (3DE) and discussed the following agenda. First, we summarized the clinical RV anatomy and function-related RV3DE use followed by the explanations about 3DSTE image acquisition, including pitfall. Next, we reviewed the reliability and feasibility of RV volume and RV ejection fraction measurements during the last decade. Besides, we described the techniques that might overcome the dropout images at RV anterior and out tract including the current limitations. Finally, speckle tracking echocardiography by RV3DE and novel RV shape assessment were reviewed. This review will help you get comprehensive information on the current status and future perspectives of RV3DE.


Asunto(s)
Ecocardiografía Tridimensional/tendencias , Ventrículos Cardíacos/diagnóstico por imagen , Predicción , Ventrículos Cardíacos/anatomía & histología , Humanos , Valores de Referencia , Volumen Sistólico , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular
2.
Hong Kong Med J ; 26(1): 44-55, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-32051329

RESUMEN

Echocardiography is a key evaluation tool for the diagnosis, prognosis, and guidance of interventional management of numerous cardiovascular conditions, including ischaemia, heart failure, and structural heart diseases. Recent technological advancements have also seen the exploration of artificial intelligence, intracardiac vortex imaging, and three-dimensional printing in echocardiography. With cardiovascular diseases increasing in prevalence worldwide, it is important for clinicians including general practitioners to have updated knowledge of appropriate use of echocardiography. As such, this article reviews the current literature and summarises the latest developments and the general clinical usage of echocardiography.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico por imagen , Ecocardiografía/métodos , Corazón/diagnóstico por imagen , Atención Primaria de Salud/métodos , Cardiología , Enfermedades Cardiovasculares/fisiopatología , Ecocardiografía Tridimensional/tendencias , Corazón/fisiopatología , Humanos
3.
Fetal Diagn Ther ; 47(5): 345-353, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31266014

RESUMEN

Since its introduction >15 years ago, the use of spatial and temporal image correlation (STIC) technology has contributed substantially to fetal echocardiography. Moreover, significant advances have occurred in 3- and 4-dimensional (3D/4D) echocardiography over the past several years including the matrix probe along with advances in gray scale and color Doppler post processing, resulting in improved display of ultrasound images. In this article, we provide examples to show these recent developments including the use of color Doppler with STIC in the glass-body mode and the matrix probe thus enabling the demonstration of cardiac anomalies of the 4-chamber-view and great arteries. The use of the matrix probe allows the examination of cardiac structures in 2 orthogonal planes simultaneously, which can help in display of anatomy side by side (Biplane mode). In addition, the rapid image reconstruction of the matrix probe allows for the display of live 4D and the rapid acquisition of a STIC volume. The display of multiplanar images of the heart in 3D/4D has also been used to automate the display of ultrasound images, resulting in standardization of the image display and thus minimizing the operation dependency of the ultrasound examination. Future addition of image recognition software can also provide assistance in image review.


Asunto(s)
Ecocardiografía Tetradimensional/métodos , Ecocardiografía Tridimensional/métodos , Corazón Fetal/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Ecocardiografía Tetradimensional/tendencias , Ecocardiografía Tridimensional/tendencias , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Embarazo , Ultrasonografía Prenatal/tendencias
4.
J Card Fail ; 25(1): 36-43, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30472281

RESUMEN

BACKGROUND: The Heartmate 3 (HM3) is a Conformiteé Européenne mark-approved left ventricular (LV) assist device (LVAD) with fully magnetically levitated rotor and features consisting of a wide range operational speeds, wide flow paths, and artificial pulse. We performed a hemodynamic-echocardiographic speed optimization evaluation in HM3-implanted patients to achieve optimal LV- and right ventricular (RV) shape. METHODS AND RESULTS: Sixteen HM3 patients underwent pump speed ramp tests with right heart catheterization. Three-dimensional echocardiographic (3DE) LV and RV datasets (Philips) were acquired, and volumetric (Tomtec) and shape (custom software) analyses were performed (LV: sphericity, conicity; RV: septal and free-wall curvatures). Data were recorded at up to 13 speed settings. Speed changes were in 100-rpm steps, starting at 4600 rpm and ramping up to 6200 rpm. 3DE was feasible in 50% of the patients. Mean original speed was 5306 ± 148 rpm. LV end-diastolic (ED) diameter (-0.15 ± 0.09 cm/100 rpm) and volumes (ED: 269 ± 109 mL to 175 ± 90 mL; end-systolic [ES]: 234 ± 111 mL to 146 ± 81 mL) progressively decreased as the shape became less spherical and more conical; RV volumes initially remained stable, but at higher speeds increased (ED: from 148 ± 64 mL to 181 ± 92 mL; ES: 113 ± 63 mL to 130 ± 69 mL). On average, the RV septum became less convex (bulging toward the LV) at the highest speeds. CONCLUSIONS: LV and RV shape changes were noted in HM3-supported patients. Although a LV volumetric decrease and shape improvement was consistently noted, RV volumes grew in response to increase in speed above a certain point. A next concern would be whether understanding of morphologic and function changes in LV and RV during LVAD speed change assessed with the use of 3DE helps to optimize LVAD speed settings and improve clinical outcomes.


Asunto(s)
Ecocardiografía Tridimensional/tendencias , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Corazón Auxiliar/tendencias , Magnetoterapia/tendencias , Anciano , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/tendencias , Femenino , Ventrículos Cardíacos/cirugía , Humanos , Magnetoterapia/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
5.
JACC Cardiovasc Imaging ; 11(12): 1854-1878, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30522687

RESUMEN

The ongoing refinements in 3-dimensional (3D) echocardiography technology continue to expand the scope of this imaging modality in clinical cardiology by offering new features that stem from the ability to image the heart in its complete dimensionality. Over the years, countless publications have described these benefits and tested new frontiers where 3D echocardiographic imaging seemed to offer promising ways to improve patients' care. These include improved techniques for chamber quantification and novel ways to visualize cardiac valves, including 3D printing, virtual reality, and holography. The aims of this review article are to focus on the most important developments in the field in the recent years, discuss the current utility of 3D echocardiography, and highlight several interesting future directions.


Asunto(s)
Ecocardiografía Tridimensional/tendencias , Cardiopatías/diagnóstico por imagen , Corazón/diagnóstico por imagen , Difusión de Innovaciones , Predicción , Corazón/fisiopatología , Cardiopatías/fisiopatología , Cardiopatías/terapia , Humanos , Valor Predictivo de las Pruebas , Pronóstico , Reproducibilidad de los Resultados
7.
Int J Cardiol ; 272: 348-355, 2018 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-29903518

RESUMEN

BACKGROUND: Right heart failure remains a major cause of morbidity and mortality after left ventricular assist device (LVAD) implantation. Multiple 2D echocardiography derived parameters are associated with right ventricular failure (RV failure), but none of them has been proven to be a reliable predictor to date. We hypothesized that novel 3D-echocardiography (3DE) based parameters are associated with RV failure and predict long term outcome in patients undergoing LVAD implantation. METHODS: This single-center study retrospectively enrolled 26 patients undergoing continuous-flow LVAD implantation. RV failure was defined as prolonged inotropic support for >14 days after LVAD implantation or consecutive implantation of a right ventricular assist device. Based on transesophageal 3DE datasets acquired prior to surgery right ventricular size, ejection fraction and longitudinal strains were calculated. RESULTS: The overall RV failure rate was 19.2%. Patients suffering from RV failure had a significantly impaired 3D-right ventricular ejection fraction (3D-RVEF; 28 ±â€¯2% vs. 19 ±â€¯3%, p = 0.0145) and 3D derived RV free wall longitudinal strain (3D-RV-fws; -13.2 ±â€¯0.97% vs. -6.4 ±â€¯1.98%; p = 0.0056) when compared to patients without RV failure. ROC analysis for 3D-RV-fws (AUC 0.914) and 3D-RVEF (AUC 0.876) showed high discriminative capabilities in regard to detection of RV failure. Kaplan-Meier analysis showed an improved long-term survival of patients with a 3D-RV-fws <-11.9%. CONCLUSIONS: 3D-echocardiography derived RV ejection fraction and RV free wall strain are associated with right ventricular failure and long term outcome in patients undergoing LVAD implantation. These parameters have the potential to be future predictors for right heart failure in LVAD surgery.


Asunto(s)
Ecocardiografía Tridimensional/tendencias , Insuficiencia Cardíaca/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Corazón Auxiliar/tendencias , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Derecha/fisiología , Adulto , Anciano , Estudios de Cohortes , Femenino , Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Disfunción Ventricular Derecha/mortalidad , Disfunción Ventricular Derecha/cirugía
8.
Int J Cardiol ; 257: 230-234, 2018 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-29395366

RESUMEN

OBJECTIVES: Our aim is to investigate the acute intraoperative effects of the NeoChord repair procedure on mitral valve (MV) annular geometry and LV function and the impact of these changes on MR at 1-year follow-up. BACKGROUND: Recently transapical off-pump mitral valve repair with NeoChord implantation has been demonstrated to be safe and effective in patients with degenerative mitral regurgitation (DMR). METHODS: We retrospectively analyzed baseline and early postoperative 3-dimensional transesophageal echocardiography of 66 patients who underwent NeoChord repair for isolated posterior leaflet MV disease using semiautomatic off-line analysis software. RESULTS: We observed a significant acute reduction of indexed LV end diastolic volume (Δ% = 14, p < .001), LV ejection fraction (Δ = 5.7%, p = .002), indexed left atrial volume (Δ = 14.7%, p = .045), and pulmonary artery pressure (Δ = 2.1%, p = .026). Among MV geometric parameters, we observed a significant reduction of MV antero-posterior diameter (Δ = 7%, p < .001), sphericity index (Δ = 8%, p < .001), annulus circumference (Δ = 0.9%, p = .021), and annulus area (Δ = 2.7%, p = .018). At 1-year, 53 patients (85.5%) presented MR ≤ mild, while 9 patients (14.5%) had MR ≥ moderate. Reduction of AP diameter (OR = 0.14, CI -3.83; 0.08, p < .001), annulus circumference (OR = 0.27, CI -2.98; 0.37, p = .005), MV area (OR = 0.39, CI -2.46; 0.61, p = .04), aorto-mitral angle (OR = 0.38, CI -2.49; 0.54, p = .002) and iEDV (OR = 0.44, CI -2.44; 0.81, p = .001) were independent protective factors against recurrence of MR greater than mild at 1-year follow-up. CONCLUSIONS: Transapical NeoChord repair produces important acute intraoperative changes in MV anatomy in DMR patients. The acute changes observed were associated with procedure durability at 1-year FU.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Monitoreo Intraoperatorio/métodos , Anciano , Anciano de 80 o más Años , Ecocardiografía Tridimensional/métodos , Ecocardiografía Tridimensional/tendencias , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio/tendencias , Sistema de Registros , Estudios Retrospectivos , Factores de Tiempo
11.
Int J Cardiol ; 248: 280-285, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-28712559

RESUMEN

BACKGROUND: The status of intrinsic left ventricular (LV) contractility in patients with isolated rheumatic mitral stenosis (MS) has been debated. The acute changes in loading conditions after percutaneous mitral valvuloplasty (PMV) may affect LV performance. We aimed to examine the acute effects of PMV on LV function and identify factors associated with LV ejection fraction (LVEF) changes, and determinants of long-term events following the procedure. METHODS: One hundred and forty-two patients who underwent PMV for symptomatic rheumatic MS (valve area of 0.99±0.3cm2) were prospectively enrolled. LV volumes and LVEF were measured by three-dimensional (3D) echocardiography. Long-term outcome was a composite endpoint of death, mitral valve (MV) replacement, repeat PMV, new onset of atrial fibrillation, and stroke. RESULTS: The mean age was 42.3±12.1years, and 125 patients were women (88%). After PMV, LVEF increased significantly (51.4 vs 56.5%, p<0.001), primary due to a significant increase in LV end-diastolic volume (65.8mL vs 67.9mL, p=0.002), and resultant increase in the stroke volume (33.9mL vs 39.6mL, p<0.001). Changes in cardiac index and systolic pulmonary artery pressure were associated with LVEF changes after PMV. During a mean follow-up period of 30.8months, 28 adverse clinical events were observed. Postprocedural mitral regurgitation, MV area, and mean gradient were independent predictors of composite endpoints. CONCLUSIONS: In patients with rheumatic MS, PMV resulted in a significant improvement in LV end-diastolic volume, stroke volume and consequently increased in LVEF. Changes in cardiac index and systolic pulmonary artery pressure were associated with LVEF changes after PMV. The predictors of long-term adverse events following PMV were post-procedural variables, including mitral regurgitation, valve area, and mean gradient.


Asunto(s)
Valvuloplastia con Balón/tendencias , Ecocardiografía Tridimensional/tendencias , Estenosis de la Válvula Mitral/diagnóstico por imagen , Cardiopatía Reumática/diagnóstico por imagen , Función Ventricular Izquierda/fisiología , Adulto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estenosis de la Válvula Mitral/fisiopatología , Estenosis de la Válvula Mitral/terapia , Estudios Prospectivos , Cardiopatía Reumática/fisiopatología , Cardiopatía Reumática/terapia , Resultado del Tratamiento
12.
Curr Pharm Des ; 23(22): 3285-3300, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28677508

RESUMEN

BACKGROUND: In the last decades, interventional cardiology has received fast and wide implementation as an effective alternative treatment to surgery for several congenital and acquired diseases. In this scenario, imaging provides solutions for most clinical needs, from diagnosis to prognosis and risk stratification, as well as anatomical and functional assessment. METHODS: In this review article, we present recent innovations in medical imaging for structural heart disease and coronary artery disease, emphasizing the progress achieved in the field of multimodality imaging and the solutions proposed to some as-yet unresolved technical problems for safe and effective procedural performance. RESULTS: Intra-procedural guidance can be facilitated by established multimodality cardiac imaging such as transesophageal 2D and 3D echocardiography and by novel techniques as echo-fluoroscopy overlay and 3D modeling/printing. Computed tomography and magnetic resonance imaging are particularly helpful for preprocedural morphology assessment and device sizing. CONCLUSION: Successful planning, performance, and aftercare of interventions depend heavily on accurate imaging for both structural heart disease and coronary artery disease.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico por imagen , Angiografía Coronaria/tendencias , Ecocardiografía Tridimensional/tendencias , Imagen por Resonancia Cinemagnética/tendencias , Tomografía Computarizada por Rayos X/tendencias , Enfermedades Cardiovasculares/cirugía , Angiografía Coronaria/métodos , Ecocardiografía Tridimensional/métodos , Humanos , Imagen por Resonancia Cinemagnética/métodos , Imagen Multimodal/métodos , Imagen Multimodal/tendencias , Tomografía Computarizada por Rayos X/métodos
15.
Int J Cardiol ; 227: 602-610, 2017 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-27814918

RESUMEN

BACKGROUND: Traditional methods of describing and classifying congenital mitral valve malformations (CMVMs) often lack specificity and scientificity. Thus, documentation is incomplete, especially in terms of ultrasound findings. METHODS: Data were collected from 436 patients (mean age, 36.6±26.8years; male 47.9%), each subjected to echocardiographic evaluation of CMVM. Valvar characteristics were studied and analyzed via a four-tiered echocardiographic analysis (FTEA) approach: (1) supravalvular region and annulus, (2) valvar leaflets and commissures, (3) chordae tendineae, and (4) papillary muscles. A clinical random ultrasonic reading controlled trial was designed to the compare conventional diagnostic method and FTEA in patients with CMVMs. RESULTS: From a total of 246,507 echocardiograms, CMVMs were methodically investigated in 436 (0.18%) patients. Of these, 16 (3.7%) had multi-level malformations; and in 133 (30.5%), CVCMs were associated with other cardiac defects. Using a FTEA approach, involvement was distributed as follows: (1) supravalvular region and annulus (n=7 [1.6%]; excessive supravalvular tissue, 3; abnormal annulus, 4 [overriding, 1; shifted, 2; bridging/cord-like accessory tissue, 1]); (2) valvar leaflets and commissures (n=421 [96.3%]; lengthy or excessive, 210; underdeveloped, 35; contracture,12; atretic, 3; anomalously connected, 1; loose or billowy, 63; clefts, 57; dual orifice, 5; localized bulging, 6; accessory tissue element, 4; fibrotic, 18; fused leaflet cusps, 3; abnormal commissures, 4 [fused, 1; clefts, 3]); (3) chordae tendineae (n=14 [3.2%]; confined to single papillary muscle, 4; excessive, 2; thickened and fused, 2; shortened, 2; fibrotic, 2; accessory tissue element, 1; straddling, 1); and (4) papillary muscles (n=13 [3.0%]; absent, 2; single, 5; asymmetric, 2; abnormally located, 3; fibrotic, 1). According to the report comparing one by one each section among the inexperienced (groups A and B) and experienced (group C) groups out of 100 patients with CMVMs, group A of the inexperienced group using the conventional diagnostic method had a score of 76±12, while group B of the inexperienced group using the FTEA method had a score of 85±11; group B scored significantly higher than group A (all P<0.05). CONCLUSIONS: Detailed incremental FTEA method in a systematic manner clearly defines malformations of the MV apparatus, ensuring more accurate diagnostic imaging. The results of clinical randomized controlled trials confirm that FTEA diagnostic accuracy was higher than conventional methods in CMVMs.


Asunto(s)
Ecocardiografía Doppler en Color/tendencias , Ecocardiografía Tridimensional/tendencias , Ecocardiografía Transesofágica/tendencias , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Válvula Mitral/anomalías , Válvula Mitral/diagnóstico por imagen , Método Doble Ciego , Ecocardiografía/tendencias , Ecocardiografía Doppler en Color/métodos , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Factores de Tiempo
16.
Curr Cardiol Rep ; 18(11): 109, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27628295

RESUMEN

Advances in ultrasound, computer, and electronics technology have permitted three-dimensional echocardiography (3DE) to become a clinically viable imaging modality, with significant impact on patient diagnosis, management, and outcome. Thanks to the inception of a fully sampled matrix transducer for transthoracic and transesophageal probes, 3DE now offers much faster and easier data acquisition, immediate display of anatomy, and the possibility of online quantitative analysis of cardiac chambers and heart valves. The clinical use of transthoracic 3DE has been primarily focused, albeit not exclusively, on the assessment of cardiac chamber volumes and function. Transesophageal 3DE has been applied mostly for assessing heart valve anatomy and function. The advantages of using 3DE to measure cardiac chamber volumes derive from the lack of geometric assumptions about their shape and the avoidance of the apical view foreshortening, which are the main shortcomings of volume calculations from two-dimensional echocardiographic views. Moreover, 3DE offers a unique realistic en face display of heart valves, congenital defects, and surrounding structures allowing a better appreciation of the dynamic functional anatomy of cardiac abnormalities in vivo. Offline quantitation of 3DE data sets has made significant contributions to our mechanistic understanding of normal and diseased heart valves, as well as of their alterations induced by surgical or interventional procedures. As reparative cardiac surgery and transcatheter procedures become more and more popular for treating structural heart disease, transesophageal 3DE has expanded its role as the premier technique for procedure planning, intra-procedural guidance, as well as for checking device function and potential complications after the procedure.


Asunto(s)
Ecocardiografía Tridimensional , Cardiopatías Congénitas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Ecocardiografía Tridimensional/tendencias , Cardiopatías Congénitas/patología , Enfermedades de las Válvulas Cardíacas/patología , Humanos , Aumento de la Imagen , Guías de Práctica Clínica como Asunto
17.
Heart ; 102(15): 1159-67, 2016 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-27048769

RESUMEN

Transoesophageal echocardiography (TOE) is used in the perioperative arena to monitor patients during life-threatening emergencies, cardiac and high-risk non-cardiac surgeries. It provides qualitative and quantitative information on valvular and ventricular functions, and dynamic cardiac anatomy can be displayed with a physiological perspective. This technology has evolved from two-dimensional (2D) to the ready availability of real-time three-dimensional (RT-3D) imaging in the operating rooms. Enhanced spatial and temporal resolutions with 3D imaging have most significantly impacted the quality of intraoperative surgical valve repair and replacement decisions. Additionally, 3D imaging has facilitated the advent of minimally invasive and percutaneous interventions for structural heart disease. Information derived from TEE is routinely used to evaluate a patient's suitability for an intervention, provide guidance during the intervention and eventually comment on the quality and success of the procedure. Expertise in perioperative TEE is an integral component of a cardiac anaesthesiologist's skill sets. With structural heart disease interventions becoming more minimally invasive, the intraoperative guidance provided by TEE will continue to be a critical component of these procedures. With improving computational and processing power, the expectations from TEE will continue to be incremental in the perioperative arena.


Asunto(s)
Ecocardiografía Doppler en Color , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Cardiopatías/diagnóstico por imagen , Cardiopatías/cirugía , Atención Perioperativa/métodos , Difusión de Innovaciones , Ecocardiografía Doppler en Color/historia , Ecocardiografía Doppler en Color/tendencias , Ecocardiografía Tridimensional/historia , Ecocardiografía Tridimensional/tendencias , Ecocardiografía Transesofágica/historia , Ecocardiografía Transesofágica/tendencias , Predicción , Cardiopatías/fisiopatología , Historia del Siglo XX , Historia del Siglo XXI , Humanos , Atención Perioperativa/historia , Atención Perioperativa/tendencias , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
20.
J Am Coll Cardiol ; 65(23): 2511-22, 2015 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-26065990

RESUMEN

BACKGROUND: Treatment-related cardiac death is the primary, noncancer cause of mortality in adult survivors of childhood malignancies. Early detection of cardiac dysfunction may identify a high-risk subset of survivors for early intervention. OBJECTIVES: This study sought to determine the prevalence of cardiac dysfunction in adult survivors of childhood malignancies. METHODS: Echocardiographic assessment included 3-dimensional (3D) left ventricular ejection fraction (LVEF), global longitudinal and circumferential myocardial strain, and diastolic function, graded per American Society of Echocardiography guidelines in 1,820 adult (median age 31 years; range: 18 to 65 years) survivors of childhood cancer (median time from diagnosis 23 years; range: 10 to 48 years) exposed to anthracycline chemotherapy (n = 1,050), chest-directed radiotherapy (n = 306), or both (n = 464). RESULTS: Only 5.8% of survivors had abnormal 3D LVEFs (<50%). However, 32.1% of survivors with normal 3D LVEFs had evidence of cardiac dysfunction by global longitudinal strain (28%), American Society of Echocardiography-graded diastolic assessment (8.7%), or both. Abnormal global longitudinal strain was associated with chest-directed radiotherapy at 1 to 19.9 Gy (rate ratio [RR]: 1.38; 95% confidence interval [CI]: 1.14 to 1.66), 20 to 29.9 Gy (RR: 1.65; 95% CI: 1.31 to 2.08), and >30 Gy (RR: 2.39; 95% CI: 1.79 to 3.18) and anthracycline dose > 300 mg/m(2) (RR: 1.72; 95% CI: 1.31 to 2.26). Survivors with metabolic syndrome were twice as likely to have abnormal global longitudinal strain (RR: 1.94; 95% CI: 1.66 to 2.28) and abnormal diastolic function (RR: 1.68; 95% CI: 1.39 to 2.03) but not abnormal 3D LVEFs (RR: 1.07; 95% CI: 0.74 to 1.53). CONCLUSIONS: Abnormal global longitudinal strain and diastolic function are more prevalent than reduced 3D LVEF and are associated with treatment exposure. They may identify a subset of survivors at higher risk for poor clinical cardiac outcomes who may benefit from early medical intervention.


Asunto(s)
Antibióticos Antineoplásicos/efectos adversos , Enfermedades Cardiovasculares/inducido químicamente , Enfermedades Cardiovasculares/diagnóstico por imagen , Ecocardiografía Tridimensional , Neoplasias/tratamiento farmacológico , Sobrevivientes , Adolescente , Adulto , Enfermedades Cardiovasculares/epidemiología , Niño , Preescolar , Estudios de Cohortes , Ecocardiografía Tridimensional/tendencias , Femenino , Estudios de Seguimiento , Humanos , Lactante , Recién Nacido , Estudios Longitudinales , Masculino , Neoplasias/epidemiología , Volumen Sistólico/efectos de los fármacos , Volumen Sistólico/fisiología , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA