Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 2.039
1.
Europace ; 26(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38696701

AIMS: Women have been historically underrepresented in implantable cardioverter-defibrillator (ICD) trials. No data on sex differences regarding subcutaneous ICDs (S-ICD) carriers have been described. Aim of our study was to investigate sex-related differences among unselected S-ICD recipients. METHODS AND RESULTS: Consecutive patients enrolled in the multicentre, international i-SUSI registry were analysed. Comparisons between sexes were performed using a 1:1 propensity matching adjusted analysis for age, body mass index (BMI), left ventricular function, and substrate. The primary outcome was the rate of appropriate shocks during follow-up. Inappropriate shocks and other device-related complications were deemed secondary outcomes. A total of 1698 patients were extracted from the i-SUSI registry; 399 (23.5%) were females. After propensity matching, two cohorts of 374 patients presenting similar baseline characteristics were analysed. Despite similar periprocedural characteristics and a matched BMI, women resulted at lower risk of conversion failure as per PRAETORIAN score (73.4% vs. 81.3%, P = 0.049). Over a median follow-up time of 26.5 [12.7-42.5] months, appropriate shocks were more common in the male cohort (rate/year 3.4% vs. 1.7%; log-rank P = 0.049), while no significant differences in device-related complications (rate/year: 6.3% vs. 5.8%; log-rank P = 0.595) and inappropriate shocks (rate/year: 4.3% vs. 3.1%; log-rank P = 0.375) were observed. After controlling for confounders, sex remained significantly associated with the primary outcome (aHR 1.648; CI 0.999-2.655, P = 0.048), while not resulting predictor of inappropriate shocks and device-related complications. CONCLUSION: In a propensity-matched cohort of S-ICD recipients, women are less likely to experience appropriate ICD therapy, while not showing higher risk of device-related complications. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT0473876.


Defibrillators, Implantable , Electric Countershock , Propensity Score , Registries , Humans , Female , Male , Middle Aged , Aged , Sex Factors , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Risk Factors , Treatment Outcome , Arrhythmias, Cardiac/therapy , Risk Assessment , Europe , Time Factors , Death, Sudden, Cardiac/prevention & control
3.
Europace ; 26(4)2024 Mar 30.
Article En | MEDLINE | ID: mdl-38584394

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Catheter Ablation , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Arrhythmias, Cardiac/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Electric Countershock/adverse effects , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Treatment Outcome
4.
Europace ; 26(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38657209

AIMS: Primary prevention patients with ischaemic cardiomyopathy and chronic total occlusion of an infarct-related coronary artery (CTO) are at a particularly high risk of implantable cardioverter-defibrillator (ICD) therapy occurrence. The trial was designed to evaluate the efficacy of preventive CTO-related substrate ablation strategy in ischaemic cardiomyopathy patients undergoing primary prevention ICD implantation. METHODS AND RESULTS: The PREVENTIVE VT study was a prospective, multicentre, randomized trial including ischaemic patients with ejection fraction ≤40%, no documented ventricular arrhythmias (VAs), and evidence of scar related to the coronary CTO. Patients were randomly assigned 1:1 to a preventive substrate ablation before ICD implantation or standard therapy with ICD implantation only. The primary outcome was a composite of appropriate ICD therapy or unplanned hospitalization for VAs. Secondary outcomes included the primary outcome's components, the incidence of appropriate ICD therapies, cardiac hospitalization, electrical storm, and cardiovascular (CV) mortality. Sixty patients were included in the study. During the mean follow-up of 44.7 ± 20.7 months, the primary outcome occurred in 5 (16.7%) patients undergoing preventive substrate ablation and in 13 (43.3%) patients receiving only ICD [hazard ratio (HR): 0.33; 95% confidence interval (CI): 0.12-0.94; P = 0.037]. Patients in the preventive ablation group also had fewer appropriate ICD therapies (P = 0.039) and the electrical storms (Log-rank: P = 0.01). While preventive ablation also reduced cardiac hospitalizations (P = 0.006), it had no significant impact on CV mortality (P = 0.151). CONCLUSION: Preventive ablation of the coronary CTO-related substrate in patients undergoing primary ICD implantation is associated with the reduced risk of appropriate ICD therapy or unplanned hospitalization due to VAs.


Catheter Ablation , Coronary Occlusion , Defibrillators, Implantable , Myocardial Ischemia , Primary Prevention , Humans , Male , Female , Middle Aged , Aged , Coronary Occlusion/mortality , Coronary Occlusion/therapy , Coronary Occlusion/prevention & control , Coronary Occlusion/complications , Treatment Outcome , Prospective Studies , Myocardial Ischemia/complications , Myocardial Ischemia/mortality , Tachycardia, Ventricular/prevention & control , Tachycardia, Ventricular/therapy , Tachycardia, Ventricular/mortality , Cardiomyopathies/mortality , Cardiomyopathies/complications , Cardiomyopathies/therapy , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Risk Factors , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Electric Countershock/mortality , Myocardial Infarction/mortality , Myocardial Infarction/prevention & control , Myocardial Infarction/complications , Chronic Disease , Time Factors
5.
Open Heart ; 11(1)2024 Mar 08.
Article En | MEDLINE | ID: mdl-38458770

The wearable cardioverter defibrillator (WCD) is becoming a more and more widely used instrument for the prevention of sudden cardiac death of patients either with a secondary prevention implantable cardioverter defibrillator indication or with a transient high risk of sudden cardiac death. Although clinical practice has demonstrated a benefit of protecting patients for a period as long as 3-6 months with such devices, the current European guidelines concerning ventricular arrhythmias and sudden cardiac death are still extremely restrictive in the patient selection in part because of the costs derived from such a prevention device, in part because of the lack of robust randomised trials.To illustrate expanded use cases for the WCD, four real-life clinical cases are presented where patients received the device slightly outside the established guidelines. These cases demonstrate the broader utility of WCDs in situations involving acute myocarditis, thyrotoxicosis, pre-excited atrial fibrillation and awaiting staging/prognosis of a lung tumour. The findings prompt expansion of the existing guidelines for WCD use to efficiently protect more patients whose risk of arrhythmic cardiac death is transient or uncertain. This could be achieved by establishing a European register of the patients who receive a WCD for further analysis.


Atrial Fibrillation , Defibrillators, Implantable , Wearable Electronic Devices , Humans , Electric Countershock/adverse effects , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Atrial Fibrillation/complications
8.
Medicina (Kaunas) ; 60(3)2024 Mar 21.
Article En | MEDLINE | ID: mdl-38541236

Out-of-hospital cardiac arrest (OHCA) is heterogeneous in terms of etiology and severity. Owing to this heterogeneity, differences in outcome and treatment efficacy have been reported from case to case; however, few reviews have focused on the heterogeneity of OHCA. We conducted a literature review to identify differences in the prognosis and treatment efficacy in terms of CA-related waveforms (shockable or non-shockable), age (adult or pediatric), and post-CA syndrome severity and to determine the preferred treatment for patients with OHCA to improve outcomes.


Cardiopulmonary Resuscitation , Out-of-Hospital Cardiac Arrest , Adult , Humans , Child , Cardiopulmonary Resuscitation/adverse effects , Out-of-Hospital Cardiac Arrest/etiology , Out-of-Hospital Cardiac Arrest/therapy , Treatment Outcome , Electric Countershock/adverse effects , Prognosis , Registries
9.
J Cardiovasc Electrophysiol ; 35(5): 1050-1054, 2024 May.
Article En | MEDLINE | ID: mdl-38501328

INTRODUCTION: Tricuspid regurgitation is associated with significant morbidity and mortality, and occurs at a higher rate in patients with cardiovascular implantable electronic devices. Percutaneous strategies for managing tricuspid regurgitation are evolving, including the development of bicaval valve implantation which has been successfully used in patients with pacing leads. METHODS AND RESULTS: We present the first documented case of lead failure following TricValve® implantation, a dedicated self-expanding system for bicaval valve implantation, and the first successful lead revision procedure in this setting. CONCLUSION: The case illustrates important considerations in undertaking percutaneous intervention in patients with cardiovascular implantable electronic devices, and their ongoing management.


Defibrillators, Implantable , Equipment Failure , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/physiopathology , Tricuspid Valve Insufficiency/diagnostic imaging , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Male , Aged , Treatment Outcome , Reoperation , Prosthesis Design , Device Removal , Female , Electric Countershock/instrumentation , Electric Countershock/adverse effects
11.
Circ Cardiovasc Qual Outcomes ; 17(4): e010061, 2024 Apr.
Article En | MEDLINE | ID: mdl-38529632

BACKGROUND: Drone-delivered automated external defibrillators (AEDs) hold promises in the treatment of out-of-hospital cardiac arrest. Our objective was to estimate the time needed to perform resuscitation with a drone-delivered AED and to measure cardiopulmonary resuscitation (CPR) quality. METHODS: Mock out-of-hospital cardiac arrest simulations that included a 9-1-1 call, CPR, and drone-delivered AED were conducted. Each simulation was timed and video-recorded. CPR performance metrics were recorded by a Laerdal Resusci Anne Quality Feedback System. Multivariable regression modeling examined factors associated with time from 9-1-1 call to AED shock and CPR quality metrics (compression rate, depth, recoil, and chest compression fraction). Comparisons were made among those with recent CPR training (≤2 years) versus no recent (>2 years) or prior CPR training. RESULTS: We recruited 51 research participants between September 2019 and March 2020. The median age was 34 (Q1-Q3, 23-54) years, 56.9% were female, and 41.2% had recent CPR training. The median time from 9-1-1 call to initiation of CPR was 1:19 (Q1-Q3, 1:06-1:26) minutes. A median time of 1:59 (Q1-Q3, 01:50-02:20) minutes was needed to retrieve a drone-delivered AED and deliver a shock. The median CPR compression rate was 115 (Q1-Q3, 109-124) beats per minute, the correct compression depth percentage was 92% (Q1-Q3, 25-98), and the chest compression fraction was 46.7% (Q1-Q3, 39.9%-50.6%). Recent CPR training was not associated with CPR quality or time from 9-1-1 call to AED shock. Younger age (per 10-year increase; ß, 9.97 [95% CI, 4.63-15.31] s; P<0.001) and prior experience with AED (ß, -30.0 [95% CI, -50.1 to -10.0] s; P=0.004) were associated with more rapid time from 9-1-1 call to AED shock. Prior AED use (ß, 6.71 [95% CI, 1.62-11.79]; P=0.011) was associated with improved chest compression fraction percentage. CONCLUSION: Research participants were able to rapidly retrieve an AED from a drone while largely maintaining CPR quality according to American Heart Association guidelines. Chest compression fraction was lower than expected.


Cardiopulmonary Resuscitation , Emergency Medical Services , Out-of-Hospital Cardiac Arrest , Humans , Female , Adult , Male , Out-of-Hospital Cardiac Arrest/diagnosis , Out-of-Hospital Cardiac Arrest/therapy , Unmanned Aerial Devices , Electric Countershock/adverse effects , Defibrillators
12.
J Cardiovasc Electrophysiol ; 35(4): 794-801, 2024 Apr.
Article En | MEDLINE | ID: mdl-38384108

INTRODUCTION: Several implantable cardioverter defibrillators (ICD) programming strategies are applied to minimize ICD therapy, especially unnecessary therapies from supraventricular arrhythmias (SVA). However, it remains unknown whether these optimal programming recommendations only benefit those with SVAs or have any detrimental effects from delayed therapy on those without SVAs. This study aims to assess the impact of SVA on the outcomes of ICD programming based on 2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement and 2019 focused update on optimal ICD programming and testing guidelines. METHODS: Consecutive patients who underwent ICD insertion for primary prevention were classified into four groups based on SVA status and ICD programming: (1) guideline-concordant group (GC) with SVA, (2) GC without SVA, (3) nonguideline concordant group (NGC) with SVA, and (4) NGC without SVA. Cox proportional hazard models were analyzed for freedom from ICD therapies, shock, and mortality. RESULTS: Seven hundred and seventy-two patients (median age, 64 years) were enrolled. ICD therapies were the most frequent in NGC with SVA (24.0%), followed by NGC without SVA (19.9%), GC without SVA (11.6%), and GC with SVA (8.1%). Guideline concordant programming was associated with 68% ICD therapy reduction (HR 0.32, p = .007) and 67% ICD shock reduction (HR 0.33, p = .030) in SVA patients and 44% ICD therapy reduction in those without SVA (HR 0.56, p = .030). CONCLUSION: Programming ICDs in primary prevention patients based on current guidelines reduces therapy burden without increasing mortality in both SVA and non-SVA patients. A greater magnitude of reduced ICD therapy was found in those with supraventricular arrhythmias.


Defibrillators, Implantable , Humans , Middle Aged , Defibrillators, Implantable/adverse effects , Electric Countershock/adverse effects , Arrhythmias, Cardiac , Death, Sudden, Cardiac/prevention & control
13.
J Cardiovasc Electrophysiol ; 35(4): 785-793, 2024 Apr.
Article En | MEDLINE | ID: mdl-38383981

INTRODUCTION: Wearable cardioverter defibrillator (WCD) is utilized in patients with assumed but not yet confirmed risk for sudden cardiac death (SCD). Many of these patients also present with atrial fibrillation (AF). However, the rate of WCD-detected ventricular or atrial arrhythmia events in this specific high-risk cohort is not well understood. METHODS: In WEARIT-II, the cumulative probability of any sustained or nonsustained VT/VF (WCD-treated and nontreated), and atrial/supraventricular arrhythmias during WCD use was assessed using the Kaplan-Meier method by prior AF, with comparisons by the log-rank test. The incidence of ventricular and atrial arrhythmia events were expressed as events per 100 patient-years, and were analyzed by prior AF using negative binomial regression. RESULTS: WEARIT-II enrolled 2000 patients, 557 (28%) of whom had AF before enrollment. Cumulative probability of any sustained or nonsustained WCD-detected VT/VF during WCD use was significantly higher among patients with a history of AF than without AF (6% vs. 3%, p = .001). Similarly, the recurrent rate of any sustained or nonsustained VT/VF was significantly higher in patients with prior AF versus no prior AF (131.5 events per 100 patient-years vs. 22.7 events per 100 patient-years, p = .001). Patients with prior AF also had a significantly higher burden of any WCD-detected atrial arrhythmias/SVT/inappropriate arrhythmias therapy (183.2 events per 100 patient-years vs. 74.8 events per 100 patient-years, p < .001). CONCLUSION: Our results demonstrate that patients with a history of AF wearing the WCD for risk assessment have a higher incidence of ventricular arrhythmias that may facilitate the decision making for ICD implantation.


Atrial Fibrillation , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Atrial Fibrillation/complications , Electric Countershock/adverse effects , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Risk Assessment , Registries , Defibrillators, Implantable/adverse effects
15.
J Cardiovasc Pharmacol Ther ; 29: 10742484231221929, 2024.
Article En | MEDLINE | ID: mdl-38291723

Aims: This study aimed to assess the safety of electric cardioversion in the absence of anesthetists assistance. We also evaluated the efficacy and safety of this procedure in older adults (≥80 years) compared to younger populations. Methods: We retrospectively analyzed the data of patients who underwent electric cardioversion at our cardiology department. Patients were divided into 2 groups according to age: ≥ 80 years and <80 years old. Results: The study included 218 participants, 73 were aged 80 years or more (mean age: 84.8 years), and 145 were younger than 80 years (mean age: 66.7 years). Electric cardioversion was effective in 97.3% of older patients and 96.5% of younger patients (P = 1.00). No thromboembolic complications were observed in either of the groups. Asystole >5 s occurred immediately after shock in 4.1% of older and 2.1% of younger patients (P = .405). Propofol was used as a sedative, with a mean dose of 0.83 mg/kg versus 0.93 mg/kg, in older and younger patients, respectively. Intubation, medical intervention, or other advanced resuscitation techniques were not required. During hospitalization, arrhythmia recurred in 9.6% and 12.4% of the older and younger patients, respectively (P = .537). Conclusions: Electrical cardioversion is an effective and safe procedure regardless of patient age. Sedation with propofol administered by cardiologists was safe. Adverse events were not considered serious or reversible.


Atrial Fibrillation , Propofol , Humans , Aged , Aged, 80 and over , Propofol/adverse effects , Electric Countershock/adverse effects , Retrospective Studies , Atrial Fibrillation/etiology , Hypnotics and Sedatives/adverse effects , Treatment Outcome
16.
Heart Rhythm ; 21(4): 410-418, 2024 Apr.
Article En | MEDLINE | ID: mdl-38246594

BACKGROUND: Outcome comparisons among subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients with nonischemic cardiomyopathies are scarce. OBJECTIVE: The aim of this study was to evaluate differences in device-related outcomes among S-ICD recipients with different structural substrates. METHODS: Patients enrolled in the i-SUSI (International SUbcutaneouS Implantable cardioverter defibrillator registry) project were grouped according to the underlying substrate (ischemic vs nonischemic) and subgrouped into dilated cardiomyopathy, hypertrophic cardiomyopathy, Brugada syndrome (BrS), arrhythmogenic right ventricular cardiomyopathy (ARVC). The main outcome of our study was to compare the rates of appropriate and inappropriate shocks and device-related complications. RESULTS: Among 1698 patients, the most common underlying substrate was ischemic (31.7%), followed by dilated cardiomyopathy (20.5%), BrS (10.8%), hypertrophic cardiomyopathy (8.5%), and ARVC (4.4%). S-ICD for primary prevention was more common in the nonischemic cohort (70.9% vs 65.4%; P = .037). Over a median (interquartile range) follow-up of 26.5 (12.6-42.8) months, no differences were observed in appropriate shocks between ischemic and nonischemic patients (4.8%/y vs 3.9%/y; log-rank, P = .282). ARVC (9.0%/y; hazard ratio [HR] 2.492; P = .001) and BrS (1.8%/y; HR 0.396; P = .008) constituted the groups with the highest and lowest rates of appropriate shocks, respectively. Device-related complications did not differ between groups (ischemic: 6.4%/y vs nonischemic: 6.1%/y; log-rank, P = .666), nor among underlying substrates (log-rank, P = .089). Nonischemic patients experienced higher rates of inappropriate shocks than did ischemic S-ICD recipients (4.4%/y vs 3.0%/y; log-rank, P = .043), with patients with ARVC (9.9%/y; P = .001) having the highest risk, even after controlling for confounders (adjusted HR 2.243; confidence interval 1.338-4.267; P = .002). CONCLUSION: Most S-ICD recipients were primary prevention nonischemic cardiomyopathy patients. Among those, patients with ARVC tend to receive the most frequent appropriate and inappropriate shocks and patients with BrS the least frequent appropriate shocks.


Arrhythmogenic Right Ventricular Dysplasia , Cardiomyopathies , Cardiomyopathy, Dilated , Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Electric Countershock/adverse effects , Arrhythmogenic Right Ventricular Dysplasia/complications , Cardiomyopathy, Dilated/complications , Cardiomyopathy, Dilated/therapy , Registries , Treatment Outcome
17.
Circ Arrhythm Electrophysiol ; 17(2): e012338, 2024 02.
Article En | MEDLINE | ID: mdl-38284289

BACKGROUND: There is no specific treatment for sudden cardiac arrest (SCA) manifesting as pulseless electric activity (PEA) and survival rates are low; unlike ventricular fibrillation (VF), which is treatable by defibrillation. Development of novel treatments requires fundamental clinical studies, but access to the true initial rhythm has been a limiting factor. METHODS: Using demographics and detailed clinical variables, we trained and tested an AI model (extreme gradient boosting) to differentiate PEA-SCA versus VF-SCA in a novel setting that provided the true initial rhythm. A subgroup of SCAs are witnessed by emergency medical services personnel, and because the response time is zero, the true SCA initial rhythm is recorded. The internal cohort consisted of 421 emergency medical services-witnessed out-of-hospital SCAs with PEA or VF as the initial rhythm in the Portland, Oregon metropolitan area. External validation was performed in 220 emergency medical services-witnessed SCAs from Ventura, CA. RESULTS: In the internal cohort, the artificial intelligence model achieved an area under the receiver operating characteristic curve of 0.68 (95% CI, 0.61-0.76). Model performance was similar in the external cohort, achieving an area under the receiver operating characteristic curve of 0.72 (95% CI, 0.59-0.84). Anemia, older age, increased weight, and dyspnea as a warning symptom were the most important features of PEA-SCA; younger age, chest pain as a warning symptom and established coronary artery disease were important features associated with VF. CONCLUSIONS: The artificial intelligence model identified novel features of PEA-SCA, differentiated from VF-SCA and was successfully replicated in an external cohort. These findings enhance the mechanistic understanding of PEA-SCA with potential implications for developing novel management strategies.


Cardiopulmonary Resuscitation , Emergency Medical Services , Heart Arrest , Out-of-Hospital Cardiac Arrest , Humans , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/etiology , Ventricular Fibrillation/therapy , Artificial Intelligence , Arrhythmias, Cardiac/complications , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Out-of-Hospital Cardiac Arrest/diagnosis , Out-of-Hospital Cardiac Arrest/therapy , Electric Countershock/adverse effects
18.
Int J Cardiol ; 400: 131807, 2024 Apr 01.
Article En | MEDLINE | ID: mdl-38272130

BACKGROUND: Left ventricular assist devices (LVADs) are an increasingly used strategy for the management of patients with advanced heart failure (HF). Subcutaneous implantable cardioverter defibrillator (S-ICD) might be a viable alternative to conventional ICDs with a lower risk of short- and long-term of device-related complications and infections.The aim of this multicenter study was to evaluate the outcomes and management of S-ICD recipients who underwent LVAD implantation. METHODS: The study population included patients with a preexisting S-ICD who underwent LVAD implantation for advanced HF despite optimal medical therapy. RESULTS: The study population included 30 patients (25 male; median age 45 [38-52] years).The HeartMate III was the most common LVAD type. Median follow-up in the setting of concomitant use of S-ICDs and LVADs was 7 months (1-20).There were no reports of inability to interrogate S-ICD systems in this population. Electromagnetic interference (EMI) occurred in 21 (70%) patients. The primary sensing vector was the one most significantly involved in determining EMI. Twenty-seven patients (90%) remained eligible for S-ICD implantation with at least one optimal sensing vector. The remaining 3 patients (10%) were ineligible for S-ICD after attempts of reprogramming of sensing vectors. Six patients (20%) experienced inappropriate shocks (IS) due to EMI. Six patients (20%) experienced appropriate shocks. No S-ICD extraction because of need for antitachycardia pacing, ineffective therapy or infection was reported. CONCLUSIONS: Concomitant use of LVAD and S-ICD is feasible in most patients. However, the potential risk of EMI oversensing, IS and undersensing in the post-operative period following LVAD implantation should be considered. Careful screening for EMI should be performed in all sensing vectors after LVAD implantation.


Defibrillators, Implantable , Heart Failure , Heart-Assist Devices , Pacemaker, Artificial , Adult , Female , Humans , Male , Middle Aged , Defibrillators, Implantable/adverse effects , Electric Countershock/adverse effects , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/complications , Heart-Assist Devices/adverse effects , Pacemaker, Artificial/adverse effects , Treatment Outcome
20.
Int J Cardiol ; 398: 131639, 2024 Mar 01.
Article En | MEDLINE | ID: mdl-38065323

INTRODUCTION: The first step-down defibrillation studies in the subcutaneous implantable cardioverter-defibrillator (S-ICD) described a defibrillation threshold (DFT) of 32.5 ± 17.0 J and 36.6 ± 19.8 J. Therefore, the default shock output of the S-ICD was set at 80 J. In de novo implants, the DFT is lower in optimally positioned S-ICDs. However, a retrospective analysis raised concerns about a high DFT in S-ICD replacements, possibly related to fibrosis. OBJECTIVE: We aimed to find the DFT in patients undergoing S-ICD generator replacement. METHODS: This prospective study enrolled patients who underwent S-ICD generator replacement with subsequent defibrillation testing. A pre-specified defibrillation testing protocol was used to determine the DFT, defined as the lowest shock output that effectively terminated the induced ventricular arrhythmia. RESULTS: A total of 45 patients were enrolled, 6.0 ± 2.1 years after initial implant. Mean DFT during replacement in the total cohort was 27.4 ± 14.3 J. In patients with a body mass index (BMI) 18.5-25 kg/m2 (N = 22, BMI 22.5 ± 1.6), median DFT was 20 J (IQR 17.5-30). In 18/22 patients, the DFT was ≤30 J and 5/22 patients were successfully defibrillated at 10 J. One patient with hypertrophic cardiomyopathy had a DFT of 65 J. In patients with a BMI >25 kg/m2 (N = 23, BMI 29.5 ± 4.2), median DFT was 30 J (IQR 20-40). In 15/23 patients, the DFT was ≤30 J and 4/23 patients had a successful defibrillation test at 10 J. CONCLUSIONS: This study eases concerns about a high DFT after S-ICD generator replacement. The majority of patients had a DFT ≤30 J, regardless of BMI, suggesting that the shock output of the S-ICD could be safely reduced.


Defibrillators, Implantable , Humans , Prospective Studies , Retrospective Studies , Electric Countershock/adverse effects , Arrhythmias, Cardiac , Ventricular Fibrillation
...