Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 1.072
1.
J Appl Oral Sci ; 32: e20230440, 2024.
Article En | MEDLINE | ID: mdl-38775557

This study aimed to compare the quality of root canal obturation (ratio of area occupied by gutta-percha (G), sealer (S), and presence of voids (V)) in different anatomical irregularities (intercanal communications, lateral irregularities, and accessory canals) located at different thirds of the root canal system of mandibular molar replicas. Sixty-seven 3D printed replicas of an accessed mandibular molar were prepared using ProGlider and ProTaper Gold rotatory systems. Three specimens were randomly selected to be used as controls and did not receive further treatment. The rest were randomly distributed in 4 experimental groups to be obturated using either cold lateral compaction (LC), continuous wave of condensation (CW), and core-carrier obturation (ThermafilPlus (TH) or GuttaCore (GC)) (n=16 per group). AHPlus® sealer was used in all groups. The three controls and a specimen from each experimental group were scanned using micro-computed tomography. The rest of the replicas were sectioned at the sites of anatomical irregularities and examined at 30× magnification. The G, S, and V ratios were calculated dividing the area occupied with each element by the total root canal area and then compared among groups using the Kruskal-Wallis test. Voids were present in all obturation techniques with ratios from 0.01 to 0.15. CW obtained a significantly higher G ratio in the irregularity located in the coronal third (0.882) than LC (0.681), TH (0.773), and GC (0.801) (p<0.05). TH and GC achieved significantly higher G ratios in those located in the apical third (p<0.05). The worst quality of obturation was observed in the loop accessory canal with all obturation techniques. Whitin the limitations of this study, it can be concluded that CW and core-carrier obturation are respectively the most effective techniques for obturating anatomical irregularities located in the coronal and the apical third.


Dental Pulp Cavity , Gutta-Percha , Materials Testing , Root Canal Filling Materials , Root Canal Obturation , X-Ray Microtomography , Root Canal Obturation/methods , Root Canal Filling Materials/chemistry , X-Ray Microtomography/methods , Gutta-Percha/chemistry , Dental Pulp Cavity/anatomy & histology , Dental Pulp Cavity/diagnostic imaging , Humans , Reproducibility of Results , Reference Values , Molar/anatomy & histology , Epoxy Resins/chemistry , Printing, Three-Dimensional , Surface Properties , Statistics, Nonparametric , Random Allocation
2.
Mymensingh Med J ; 33(2): 605-612, 2024 Apr.
Article En | MEDLINE | ID: mdl-38557547

Accomplishment of an ideal root canal treatment is attributed to various essential factors such as proper instrumentation, chemomechanical preparation, obturation and post endodontic restoration. The main aim of this study is to test the null hypothesis that is the moisture condition of root dentin would not affect the bond strength and sealer penetration. This is an in vitro study conducted in Department of Conservative Dentistry and Endodontics, M A Rangoonwala Dental College, Pune, India over a period of two years (from 2021 to 2023). One hundred and twenty single-rooted Premolars with fully formed apices and similar root morphology were obtained and stored in 0.1% thymol solution. The specimens were randomly assigned to 3 broad experimental groups (n=40) according to the drying protocol such as Group A- Paper points (P), Group B- diode laser (L) and Group C- isopropyl alcohol (A). For each drying protocol, the specimens were further assigned to 2 subgroups (n=20) with respect to the sealers used: AH Plus (AH) and Apexit Plus sealers (APx). The effect of drying protocol using paper points, isopropyl alcohol and diode-lasers on the bond strength and tag penetration of two different sealers to the root dentin was evaluated. Maximum overall push-out Bond strength was seen in group AH+L and least in group APx+ L. Inter-site push-out bond Strength was highest in the coronal third followed by the middle and least in the apical third of all the groups. Maximum over all depth of penetration was seen in group AH+L and minimum in group APx+L. AH plus sealer showed better bond strength, sealer penetration and adaptation to the dentinal walls compared to Apexit plus sealer, irrespective of the drying protocol followed. All the drying protocols used did not show statistically significant results in the apical thirds of root canals of all the groups.


Calcium Hydroxide , Root Canal Filling Materials , Humans , Root Canal Filling Materials/analysis , Root Canal Filling Materials/chemistry , Epoxy Resins/analysis , Epoxy Resins/chemistry , 2-Propanol/analysis , India , Dentin/chemistry
3.
Biomed Mater ; 19(4)2024 May 10.
Article En | MEDLINE | ID: mdl-38688325

Bone fracture plates are usually made from steel or titanium, which are much stiffer than cortical bone. This may cause bone 'stress shielding' (i.e. bone resorption leading to plate loosening) and delayed fracture healing (i.e. fracture motion is less than needed to stimulate callus formation at the fracture). Thus, the authors previously designed, fabricated, and mechanically tested novel 'hybrid' composites made from inorganic and organic materials as potential bone fracture plates that are more flexible to reduce these negative effects. This is the first study to measure the cytotoxicity of these composites via the survival of rat cells. Cubes of carbon fiber/flax fiber/epoxy and glass fiber/flax fiber/epoxy had better cell survival vs. Kevlar fiber/flax fiber/epoxy (57% and 58% vs. 50%). Layers and powders made of carbon fiber/epoxy and glass fiber/epoxy had higher cell survival than Kevlar fiber/epoxy (96%-100% and 100% vs. 39%-90%). The presence of flax fibers usually decreased cell survival. Thus, carbon and glass fiber composites (with or without flax fibers), but not Kevlar fiber composites (with or without flax fibers), may potentially be used for bone fracture plates.


Bone Plates , Carbon Fiber , Cell Survival , Fractures, Bone , Glass , Materials Testing , Animals , Rats , Cell Survival/drug effects , Glass/chemistry , Carbon Fiber/chemistry , Biocompatible Materials/chemistry , Carbon/chemistry , Fracture Healing , Epoxy Resins/chemistry , Stress, Mechanical , Titanium/chemistry
4.
J Endod ; 50(5): 659-666, 2024 May.
Article En | MEDLINE | ID: mdl-38431198

INTRODUCTION: To evaluate the push-out bond strength (POBS) of AH Plus sealer to root dentin and the adhesive interface quality after calcium hydroxide (Ca(OH)2) intracanal dressing removal with different final irrigation protocols. METHOD: After root canal instrumentation and irrigation, 40 root canals were filled with Ca(OH)2 and sealed. After 14 days, the specimens were randomly distributed according to the irrigation protocols for Ca(OH)2 removal (n = 10): GH2O (control) - distilled water; GNaOCl - 1% NaOCl; GEDTA - 17% EDTA; GEDTA + NaOCl - 17% EDTA + 1% NaOCl. The root canals were filled with AH Plus sealer and gutta-percha. After 7 days, the roots were sectioned into dentin slices and submitted to POBS test and analysis of the adhesive interface under scanning electron microscope. The POBS data were statistically evaluated (analysis of variance and Tukey test). The Kruskal-Wallis and Mann-Whitney tests were used to analyze the adhesive interface (α = 0.05). RESULTS: GH2O, GNaOCl, and GEDTA + NaOCl had similar POBS values, with higher values on the apical third, in comparison with other thirds (P < .05). A homogeneous and free-of-gaps adhesive interface was observed for GH2O, GNaOCl, and GEDTA + NaOCl, with difference between GH2O and GEDTA (P < .05). GH2O and GEDTA + NaOCl presented higher sealer tags formation (P < .05). CONCLUSION: The final rinse with EDTA for Ca(OH)2 dressing removal had a negative effect on the POBS of the filling material to root dentin. The use of EDTA followed by NaOCl had results similar to the distilled water, providing uniform and free-of-gaps adhesive interface, and a higher number of sealer tags.


Calcium Hydroxide , Dental Bonding , Dentin , Epoxy Resins , Root Canal Filling Materials , Root Canal Irrigants , Therapeutic Irrigation , Calcium Hydroxide/chemistry , Humans , Dentin/drug effects , Root Canal Filling Materials/chemistry , Epoxy Resins/chemistry , Dental Bonding/methods , Therapeutic Irrigation/methods , Dental Pulp Cavity/drug effects , Microscopy, Electron, Scanning , Sodium Hypochlorite/chemistry , Edetic Acid , Root Canal Preparation/methods , Dental Stress Analysis , Materials Testing
5.
Int J Biol Macromol ; 267(Pt 1): 131189, 2024 May.
Article En | MEDLINE | ID: mdl-38554924

The current study presents the synergistic effects of fibrillated cellulose (FC) and nickel-titanium (NiTi) alloy on the performance properties of smart composites. Epoxy resin was reinforced with loadings of 1 %, 3 %, and 5 % FC and 3 % NiTi. The composites were produced using the casting method. The morphological properties have been analyzed using scanning electron microscopy (SEM). For mechanical properties, yield strength, modulus of elasticity, hardness, and impact energy were determined. The corrosion rate was determined via electrochemical corrosion testing. The recovery test was used to measure the shape-memory of the composites. The self-healing of the artificial defect in the composites was observed using a thermal camera. The yield strength, modulus of elasticity, hardness, and impact energy of composites reinforced with 5 % FC and 3 % NiTi increased by 168.2 %, 290 %, 33.3 %, and 114.3 %, respectively, compared to pure epoxy resin. There has been a 56.3 % decrease in the corrosion rate. The percentage of composites that returned from the final state to the original state after a deformation was 4 %. Self-healing analysis revealed that the scratch defect in composites was healed after 24 h. It is concluded that smart composites can be used in the aviation and automotive industries.


Alloys , Cellulose , Nickel , Titanium , Cellulose/chemistry , Nickel/chemistry , Titanium/chemistry , Alloys/chemistry , Corrosion , Materials Testing , Epoxy Resins/chemistry , Hardness
6.
Am J Dent ; 37(1): 35-38, 2024 Feb.
Article En | MEDLINE | ID: mdl-38458981

PURPOSE: To assess the push out bond strength (POBS) of a syringe-mixed resin sealer and a premixed bioceramic sealer to root dentin exposed to different gutta-percha (GP) solvents and to determine the mode of failure. METHODS: A total of 200 horizontal root slices (1 mm thickness) were prepared up to size 40, 0.04 taper and randomly divided into four main groups based on solvent (Endosolv, orange oil, chloroform) and control (saline), then subdivided into two subgroups based on sealer type (AH Plus Jet and iRoot SP). Samples were exposed to respective solvents for 5 minutes and after the final rinsing, canal spaces were filled with either AH Plus Jet or iRoot SP. POBS test was performed 2 weeks after incubation and mode of failure following POBS test was evaluated. Data were analyzed using two-way ANOVA and Dunnett post hoc analysis (P< 0.05). Failure mode patterns were categorized as adhesive, cohesive and mixed failures. RESULTS: There was no significant difference (P> 0.05) in POBS between all solvent groups against the control in both AH Plus Jet and iRoot SP groups. Regardless of the use of solvents, AH Plus Jet group had significantly higher bond strength (P< 0.001) compared to iRoot SP group. The predominant mode of failure was mixed failure in all groups irrespective of type of sealer and exposure to solvents. CLINICAL SIGNIFICANCE: This study showed that exposure to gutta-percha solvents (chloroform, orange oil and Endosolv) for 5 minutes did not affect the bond strengths of both iRoot SP (bioceramic sealer) and AH Plus (resin sealer) to root dentin.


Dental Bonding , Root Canal Filling Materials , Silicates , Gutta-Percha/chemistry , Epoxy Resins/chemistry , Solvents , Chloroform , Syringes , Root Canal Filling Materials/chemistry , Dentin , Materials Testing
7.
J Oral Sci ; 66(2): 96-101, 2024 Apr 16.
Article En | MEDLINE | ID: mdl-38325857

PURPOSE: This study evaluated the dentin bonding strength and biomineralization effect of a recently developed premixed calcium aluminate-based endodontic sealer (Dia-Root Bio Sealer) in comparison with existing calcium silicate-based sealers. METHODS: The root canals of 80 mandibular premolars were filled with Dia-Root Bio Sealer, Endoseal MTA, EndoSequence BC Sealer, and AH Plus Bioceramic Sealer. Medial and apical specimens were then obtained by sectioning. The push-out bond strength was measured using the medial specimens, and the failure mode was recorded. Intratubular biomineralization in the apical specimens was analyzed using scanning electron microscopy and energy-dispersive X-ray spectroscopy (EDS). The data were analyzed using one-way analysis of variance followed by the Tukey test (P < 0.05). RESULTS: The push-out bond strength of Dia-Root Bio Sealer was significantly higher than that of the other tested materials, and a cohesive failure pattern was observed in all groups. Dia-Root Bio Sealer also exhibited a significantly higher degree of biomineralization than the other groups, and EDS analysis indicated that the biomineralized precipitates were amorphous calcium phosphate. CONCLUSION: The results of this study indicate that Dia-Root Bio Sealer has the potential to be used as an adequate root canal sealer due to its favorable bonding performance.


Aluminum Compounds , Calcium Compounds , Dental Bonding , Root Canal Filling Materials , Root Canal Filling Materials/chemistry , Epoxy Resins/chemistry , Epoxy Resins/pharmacology , Biomineralization , Dental Bonding/methods , Materials Testing , Dentin , Silicates/chemistry
8.
J Adhes Dent ; 26(1): 65-78, 2024 Jan 15.
Article De | MEDLINE | ID: mdl-38379400

PURPOSE: Multiple materials are found in the root canal after fiber-post cementation. The layer of a bioceramic-based (BC) sealer may affect the bond strength (σBS) of the fiber post in the root canal. The purpose of this study was to employ multilayer compos-ite-disk models in diametral compression to investigate whether the bond strength between a fiber post and root dentin can be in-creased by the application of a primer on the BC sealer. MATERIALS AND METHODS: The multilayers of materials in the root canal required 3D finite-element (FE) stress analyses (FEA) to pro-vide precise σBS values. First, BC sealer was characterized using x-ray powder diffraction (XRD) to determine when the sealer com-pletely set and the types of crystals formed to select which primer to apply to the sealer. We selected a 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP)-based primer to treat the BC sealer before post cementation. Ultra-highspeed (UHS) imaging was utilized to analyze the crack initiation interface. The obtained failure force was used in FE analysis to calculate σBS. RESULTS: UHS imaging validated the fracture interface at the post-dentin junction as FEA simulations predicted. σBS values of the fiber posts placed with various material combinations in the root canal were 21.1 ± 3.4 (only cement/ post), 22.2 ± 3.4 (BC sealer/cement/post) and 28.6 ± 4.3 MPa (10-MDP primer treated BC sealer/cement/post). The 10-MDP-treated BC sealer exhibited the highest σBS (p < 0.05). CONCLUSION: The multilayer composite disk model proved reliable with diametral compression testing. The presence of BC sealer in the root canal does not reduce σBS of the fiber post. Conditioning the BC sealer layer with 10-MDP primer before fiber-post cemen-tation increases σBS.


Dental Bonding , Methacrylates , Root Canal Filling Materials , Root Canal Filling Materials/chemistry , Root Canal Filling Materials/pharmacology , Epoxy Resins/chemistry , Epoxy Resins/pharmacology , Dental Pulp Cavity , Materials Testing , Dentin
9.
J Endod ; 50(3): 381-388, 2024 Mar.
Article En | MEDLINE | ID: mdl-38219956

INTRODUCTION: A number of sealers with different chemistries are badged as Bioceramic, implying biological activity, but have dissimilar properties, which has implications on the sealer properties and will affect the quality and outcome of root canal treatment. This study aimed to assess the physical and chemical properties of 3 hydraulic cement-based sealers, namely BC Universal sealer compared with Totalfill BC sealer and AH Plus Bioceramic. METHODS: The microstructure and composition of the sealers were assessed using scanning electron microscopy and energy dispersive spectroscopy after setting. The crystalline phases were assessed by X-ray diffraction analysis and the leachates were tested using inductively coupled plasma. All testing was performed at 0, 7, and 28 days. The physical properties of film thickness, flow, radiopacity, and solubility were evaluated using ISO 6876:2012 standards. RESULTS: All 3 sealers contained calcium, zirconium, and silicon. Totalfill BC had the highest calcium release at 7 and 28 days followed by AH Plus Bioceramic and BC Universal sealer. All 3 sealers adhered to the ISO standard in terms of flow and radiopacity. BC Universal sealer was slightly over the range (>50 µm) for film thickness. All sealers exceeded the solubility range set by ISO 6876:2012. CONCLUSION: Although these hydraulic cement sealers had similar components and delivery, the properties varied significantly. The testing of material properties to confirm the suitability for clinical use is necessary.


Root Canal Filling Materials , Root Canal Filling Materials/chemistry , Epoxy Resins/chemistry , Calcium , Calcium Compounds/chemistry , Syringes , Materials Testing , Dental Cements , Glass Ionomer Cements , Silicates/chemistry
10.
J Mech Behav Biomed Mater ; 151: 106400, 2024 Mar.
Article En | MEDLINE | ID: mdl-38262184

AIM: To mensure the physicochemical properties of three ceramic cement endodontic sealers AH Plus Bioceramic, Bio-C Sealer and Bio-C Sealer Ion+ with an epoxy resin sealer, AH Plus. MATERIAL AND METHODS: These properties were measured: hardening time (HT), dimensional change (DC), solubility (SL), flow (FL) and radiopacity (RD). The distilled water obtained from the SL test was analyzed with atomic absorption spectrometry. A sample calculation was made considering n = 5 repetitions for each experimental sealer evaluated. Statistical analysis was performed using one-way ANOVA and post hoc Tukey tests (p < 0.05). RESULTS: For the HT, AH Plus (484 ± 2.76 min) and AH Plus Bioceramic (424 ± 1.23 min) set more slowly than of Bio-C Sealer (370 ± 4.50 min) and Bio-C Sealer Ion+ (380 ± 1.42 min) (p < 0.05). AH Plus Bioceramic (12.56 ± 2.71 %) was more soluble than Bio-C Sealer (6.69 ± 1.67 %), Bio-C Sealer Ion+ (5.67 ± 2.16 %) and AH Plus (0.15 ± 0.01 %) (p < 0.05). AH Plus (0.03 ± 0.01 %) had slight expansion while the cement-based sealers had shrinkage: AH Plus Bioceramic (-1.60 ± 0.63 %) and Bio-C Sealer (-1.38 ± 0.69 %), Bio-C Sealer Ion+ (-5.19 ± 1.23 %) (p < 0.05). Bio-C Sealer Ion+ (59.80 ± 0.86 mm) and Bio-C Sealer (58.60 ± 0.98 mm) had the highest flow compared with AH Plus (56.90 ± 0.56 mm) and AH Plus Bioceramic (49.50 ± 0.63 mm) (p < 0.05). AH Plus (9.17 ± 0.06 mmAl) and AH Plus Bioceramic (8.27 ± 0.84 mmAl) showed radiopacity values when compared with those of Bio-C Sealer (4.90 ± 0.08 mmAl) and Bio-C Sealer Ion+ (4.14 ± 0.05 mmAl) (p > 0.05). CONCLUSION: Ion release is inhered to these cement-based sealers and this result in calcium ion release.


Calcium , Root Canal Filling Materials , Calcium/chemistry , Root Canal Filling Materials/chemistry , Calcium Compounds/chemistry , Epoxy Resins/chemistry , Silicates/chemistry , Materials Testing
11.
Head Face Med ; 20(1): 2, 2024 Jan 03.
Article En | MEDLINE | ID: mdl-38172921

BACKGROUND: The aim of this study was to evaluate the physicochemical properties of two newly introduced premixed calcium silicate-based root canal sealers (AH Plus Bioceramic Sealer and Bio-C Sealer) compared to a resin-based root canal sealer (ADseal root canal sealer). METHODS: Solubility, pH analysis, calcium ion release, and film thickness of each sealer were evaluated following ISO guidelines. The data were examined using the two-way ANOVA test. Furthermore, X-ray diffraction (XRD) examination was performed to investigate the crystalline phase of each type of sealer. X-ray fluorescence (XRF) analysis was done for the chemical elemental analysis of each sealer. RESULTS: The least film thickness, highest alkalinity, and highest calcium ion release were all displayed by AH Plus Bioceramic Sealer. High solubility, high alkalinity, intermediate calcium ion release, and intermediate film thickness were all displayed by Bio-C Sealer. While ADseal root canal sealer displayed the greatest film thickness, least solubility, alkalinity, and calcium ion release. CONCLUSIONS: Both AH Plus Bioceramic Sealer and Bio-C Sealer represented adequate properties to be considered a good sealer that could be used as a potential alternative to resin-based root canal sealers.


Calcium , Root Canal Filling Materials , Humans , Calcium/chemistry , Dental Pulp Cavity , Root Canal Filling Materials/chemistry , Epoxy Resins/chemistry , Calcium Compounds/chemistry , Silicates/chemistry , Materials Testing
12.
Histol Histopathol ; 39(3): 279-292, 2024 Mar.
Article En | MEDLINE | ID: mdl-37747049

Odontology, as a scientific discipline, continuously collaborates with biomaterials engineering to enhance treatment characteristics and patients' satisfaction. Endodontics, a specialized field of dentistry, focuses on the study, diagnosis, prevention, and treatment of dental disorders affecting the dental pulp, root, and surrounding tissues. A critical aspect of endodontic treatment involves the careful selection of an appropriate endodontic sealer for clinical use, as it significantly influences treatment outcomes. Traditional sealers, such as zinc oxide-eugenol, fatty acid, salicylate, epoxy resin, silicone, and methacrylate resin systems, have been extensively used for decades. However, advancements in endodontics have given rise to bioceramic-based sealers, offering improved properties and addressing new challenges in endodontic therapy. In this review, a classification of these materials and their ideal properties are presented to provide evidence-based guidance to clinicians. Physicochemical properties, including sealing ability, stability over time and space, as well as biological properties such as biocompatibility and antibacterial characteristics, along with cost-effectiveness, are essential factors influencing clinicians' decisions based on individual patient evaluations.


Biocompatible Materials , Root Canal Filling Materials , Humans , Root Canal Filling Materials/chemistry , Materials Testing , Epoxy Resins/chemistry , Zinc Oxide-Eugenol Cement
13.
Int J Biol Macromol ; 254(Pt 2): 127760, 2024 Jan.
Article En | MEDLINE | ID: mdl-37926316

The application of epoxidized soybean oil (ESO) in thermosetting polymers is impeded by its unsatisfactory thermomechanical properties. Here, in order to address the limitation, technical lignin was modified by tung oil anhydride and then used as the hardener to compensate for the inherent flexibility defects of ESO thermosets (TLs). As the lignin content increased, a notable improvement in the activation energy of TLs was observed, attributed to the restraining effect of lignin's rigid structure on segmental relaxation. Concurrently, the tensile strength of TLs increased from 2.8 MPa to 34.0 MPa, concomitant with a decrease in elongation at break from 32.9 % to 8.0 %. Comparative analysis with TL-0 (devoid of lignin) demonstrated substantial enhancements in glass transition temperature, shape fixation ratio, and shape recovery ratio for TL-50 (comprising 50 wt% of lignin), elevating from 16.9 °C, 89.1 %, and 89.5 % to 118.6 °C, 94.0 %, and 99.3 %, respectively. These results unequivocally highlight the favorable dynamic mechanical and shape memory properties conferred upon TLs by lignin addition. While the introduction of lignin adversely affected thermal stability, a notable improvement in char yield (800 °C) was observed. Collectively, these findings underscore the potential of technical lignin as a promising bio-based curing agent for ESO.


Epoxy Resins , Lignin , Epoxy Resins/chemistry , Soybean Oil/chemistry , Polymers/chemistry
14.
Int J Biol Macromol ; 256(Pt 1): 128041, 2024 Jan.
Article En | MEDLINE | ID: mdl-37979768

Due to environmental issues, production costs, and the low recycling capability of conventional epoxy polymers and their composites, many science groups have tried to develop a new type of epoxy polymers, which are compatible with the environment. Considering the precursors, these polymers can be produced from plant oils, saccharides, lignin, polyphenol, and natural resins. The appearance of these bio-polymers caused to introduce a new type of composites, namely bio-epoxy nanocomposites, which can be classified according to the synthesized bio-epoxy, the used nanomaterials, or both. Hence, in this work, various bio-epoxy resins, which have the proper potential for application as a matrix, are completely introduced with the synthesis viewpoint, and their characterized chemical structures are drawn. In the next steps, the bio-epoxy nanocomposites are classified based on the used nanomaterials, which are carbon nanoparticles (carbon nanotubes, graphene nanoplatelets, graphene oxide, reduced graphene oxide, etc.), nano-silica (mesoporous and spherical), cellulose (nanofibers and whiskers), nanoclay and so on. Also, the features of these bio-nanocomposites and their applications are introduced. This review study can be a proper guide for developing a new type of green nanocomposites in the near future.


Graphite , Nanocomposites , Nanotubes, Carbon , Lignin , Rubber , Polyphenols , Epoxy Resins/chemistry , Nanotubes, Carbon/chemistry , Polymers , Nanocomposites/chemistry , Plant Oils
15.
Dent Mater ; 40(3): 387-392, 2024 Mar.
Article En | MEDLINE | ID: mdl-38103958

INTRODUCTION: Biological characterization of root canal sealers is important as it assesses the ability of the root canal sealer to exert antimicrobial properties thus avoiding treatment failures caused by microbial challenge and also assess the cytotoxic effect on the periapical tissues. Assessment of the biological testing of root canal sealers necessitates the sterilisation of the materials prior to evaluation. This study aims to analyse the influence of various sterilisation techniques conducted prior to biological testing on the microstructure and surface properties of endodontic sealers. Assessment of the initial microbial contamination on the material was also undertaken. METHODS: Four commercial sealers were investigated. The sealers were either prepared in a laminar flow cabinet or on a laboratory bench top under ambient conditions. Each group was further divided into 5 groups (n = 3) based on the sterilization technique:1) ethanol-10 mins, 2) ultraviolet-1 h, 3) ethanol-10 mins + ultraviolet-1 h, 4) autoclave, and 5) no sterilisation (control). Microbial levels in the materials were assessed by plate streaking technique. The materials were characterized by scanning electron microscopy and energy dispersive spectroscopy, and Fourier transform infrared spectroscopy, before and after sterilisation, to assess any changes in microstructure and chemical composition. RESULTS: All the materials did not exhibit contamination when prepared in laminar flow chamber in sterile conditions compared with sealers prepared on the bench top. Three of the commercial materials showed changes in microstructure while one (TotalFill) was not affected by the sterilisation. AH Plus and BioRoot RCS exhibited alterations in water and alcohol peaks in FT-IR while the single syringe sealers (TotalFill and BioRoot Flow) showed no changes. CONCLUSIONS: Sterilisation methods cause physical and chemical alterations to sealers. Material preparation should be performed in a laminar flow cabinet and a test for sterility should be performed prior to any biological testing being undertaken. If the materials are not sterile, assessment of the effects of the sterilization methods is recommended.


Root Canal Filling Materials , Epoxy Resins/chemistry , Gutta-Percha/chemistry , Spectroscopy, Fourier Transform Infrared , Dental Pulp Cavity , Calcium Compounds/chemistry , Materials Testing , Ethanol , Silicates/chemistry
16.
Microsc Res Tech ; 87(1): 114-121, 2024 Jan.
Article En | MEDLINE | ID: mdl-37712652

It was aimed to compare the dentine tubule penetration of AH Plus, MTA Bioseal, and WellRoot ST after filling, retreating, and reshaping the root canals by using a novel microscopic method. Seventy-five mandibular incisors with single root canals were shaped with Protaper Next system (PTN; X2-25/0.06) The teeth were obturated with AH Plus labeled with Rhodamin B and MTA Bioseal or WellRoot ST sealer which were labeled with Fluo-3. Then the root canal fillings were removed with Protaper Universal Retreatment files. At the last stage, the teeth were reshaped with PTN (X3-30/0.07). The samples were transversally sectioned and examined using a Cytation 5 reader and Gen5 software regarding the mean and the maximum depth of sealer penetration. No significant difference was observed between the groups, except for the 6 mm level after reshaping the root canals (p < .05). It is not possible to completely remove the sealer remnants from the dentin walls even after reshaping the root canals. RESEARCH HIGHLIGHTS: Even after reshaping the root canals in the retreatment procedure, it is not possible to completely remove the filling residues of the epoxy-resin-based, calcium-silicate-based and MTA-based endodontic pastes from the dentin walls.


Dental Pulp Cavity , Root Canal Filling Materials , Dentin , Root Canal Filling Materials/chemistry , Epoxy Resins/chemistry , Root Canal Obturation/methods , Retreatment , Root Canal Preparation/methods , Gutta-Percha
17.
Dent Mater ; 40(3): 420-430, 2024 Mar.
Article En | MEDLINE | ID: mdl-38123383

OBJECTIVES: Final root canal irrigation should ideally maintain the physicochemical stability of root canal sealers. We seek to assess the effect of contact with 2% chlorhexidine digluconate (CHX) on the physicochemical properties of AH Plus, BioRoot™ RCS, and Pulp Canal Sealer (PCS). METHODS: Mixed sealers were placed in cylindrical teflon molds and allowed to set for 1.5x the manufacturers' setting time. Half of the specimens had their free surface in contact with CHX for the first minute of their setting period. Solubility, radiopacity, surface roughness, microhardness and wettability of the sealers were assessed up to 28 days after setting. Elemental analysis of sealer surfaces and their leachates together with pH measurements were also performed. Appropriate parametric and non-parametric analysis with post hoc tests were performed (p < 0.05). RESULTS: Exposure to CHX had no effect on solubility and radiopacity of all sealers. CHX altered the surface roughness of PCS and BioRoot RCS (p < 0.05). Contact with CHX reduced the microhardness of AH Plus and PCS (p < 0.05). AH Plus was more hydrophilic after CHX contact, whereas PCS became more hydrophobic (p < 0.05). AH Plus and PCS surfaces appeared to adsorb CHX as exhibited by chlorine peaks after contact with CHX. Sealer leachates' alkalinity was not affected. CHX increased elution of silicon and zirconium for BioRoot and zinc for PCS leachates. SIGNIFICANCE: In our study, CHX affected sealers' physicochemical properties to various extents. Further studies are needed to confirm the obtained results by investigating various final irrigation strategies and correlating to biological properties.


Chlorhexidine/analogs & derivatives , Root Canal Filling Materials , Epoxy Resins/chemistry , Materials Testing , Silicates/chemistry
18.
Chin J Dent Res ; 26(4): 249-256, 2023 Dec 21.
Article En | MEDLINE | ID: mdl-38126370

OBJECTIVE: To compare calcium silicate-based endodontic sealer and epoxy resin-based sealer remnants on root canal walls after post space preparation and their influence on the bond strength of fibre posts fixed with a dual-cured resin cement. METHODS: Thirty-six extracted single-root mandibular premolars were instrumented and divided randomly into two equal groups with different endodontic sealers. iRoot SP (Innovative BioCeramix, Vancouver, Canada) was employed in the experimental group and AH Plus (Dentsply Sirona, Charlotte, NC, USA) was used in the control group. Sealer remnants were observed under an endodontic microscope after root canal therapy and post space preparation. Fibre posts were fixed with dual-cured resin cement. Specimens were taken at each third of the post space. The push-out bond strength was measured using a universal testing machine and fracture modes were assessed. Statistical analysis was performed using an independent samples t test and one-way analysis of variance. RESULTS: There was no statistically significant difference in bond strength of fibre posts between the control and experimental group (P > 0.05); however, sealer remnants were observed in 38.9% of the samples treated with iRoot SP and none of the samples treated with AH Plus. The major fracture mode in samples treated with iRoot SP was adhesive failure between the resin cement and the post, and no adhesive failure between the resin cement and dentine occurred at the site of the sealer remnant. The presence of iRoot SP remnants on the root canal walls after post space preparation did not interfere with bonding. CONCLUSION: iRoot SP is a viable option for root canal obturation before fibre post cementation.


Dental Bonding , Root Canal Filling Materials , Resin Cements/chemistry , Dental Bonding/methods , Root Canal Filling Materials/chemistry , Epoxy Resins/chemistry , Materials Testing , Dentin
19.
Braz Dent J ; 34(4): 34-43, 2023.
Article En | MEDLINE | ID: mdl-37909640

This study evaluated the effect of heating on the physicochemical properties and surface changes of tricalcium silicate sealers. Three tricalcium silicate root canal sealers (Bio-C Sealer, BioRoot-RCS, EndoSequence BC Sealer), and one epoxy resin-based sealer (AH Plus; control) were tested. The effect of heating on setting time (ST) and flowability were assessed according to ANSI/ADA 57 and ISO 6876 standards. Solubility and dimensional change (DC) of the set sealers were evaluated at 24 hours and after 30 days; the pH of the water used in the DC testing was also measured. Tests were repeated with heated sealers in an oven at 100 °C for 1 min. SEM and EDS analysis were performed. Data were analyzed using One-Way ANOVA and Tukey post-hoc tests (α=5%). Heating decreased the ST for AH Plus and EndoSequence (p<0.05). Heating reduced flowability (p<0.05) and increased pH for AH Plus (p<0.05). The solubility of Bio-C (dried specimens) was not in accordance with the ANSI/ADA standard. The solubility of EndoSequence was significantly higher (p<0.05) when it was heated and dried after 30 days. DC of Bio-C (24 h and 30 days), BioRoot-RCS (30 days) and AH Plus (24 h and 30 days) were not in accordance with the standards. SEM and EDS analysis showed significant changes in sealer microstructure after heating. In conclusion, heating decreased the ST and increased the solubility of EndoSequence BC sealer. No significant changes in flowability, DC, and pH were identified for all three tricalcium silicate sealers after heat application. However, all sealers had significant surface changes.


Root Canal Filling Materials , Root Canal Filling Materials/chemistry , Heating , Dental Pulp Cavity , Calcium Compounds/chemistry , Epoxy Resins/chemistry , Silicates/chemistry , Materials Testing
20.
Clin Oral Investig ; 27(12): 7919-7933, 2023 Dec.
Article En | MEDLINE | ID: mdl-38032392

AIM: To evaluate the bond strength (BS) and analysis of the adhesive interface in root canals filled with bioceramic gutta percha sealers and cones. MATERIAL AND METHODS: Ninety-six maxillary canines were divided into eight groups according to the endodontic sealer (AH Plus, AH Plus Bioceramic, Bio-C Sealer or Bio-C Sealer Ion+ and gutta percha cones (conventional or bioceramic) tested. They were analyzed using the BS test, failure pattern, analysis of the adhesive interface by scanning electron microscopy and confocal laser scanning microscopy. The BS data were compared between groups using the analysis of variance test with the Turkey post-test. The chi-square test was used to assess the type of failure and the non-parametric Mann-Whitney and Kruse-Wallis tests (P < 0.05). RESULTS: Analysis of variance showed higher BS values for the groups of bioceramic gutta percha cones in Bio-C Sealer Ion+ (8.38 ± 4.27), AH Plus Bioceramic (6.19 ± 3.28), Bio-C Sealer (5.70 ± 3.18), AH Plus (4.61 ± 2.11) and for conventional gutta percha cones in AH Plus sealers (4.26 ± 2.35), Bio-C Sealer Ion + (3.63 ± 2.29), Bio-C Sealer (2.94 ± 2.32) and AH Plus Bioceramic (1.19 ± 0.89) (P < 0.05). Relative to the type of failure and adaptation of the types of filling material, a higher percentage of mixed failures was observed (gaps between 1 µm-10 µm) for the group with bioceramic gutta percha cones (P < 0.001). CONCLUSION: The bond between sealers and bioceramic gutta percha cones showed higher bond strength values and greater penetration into the dentin tubules. CLINICAL RELEVANCE: The filling the root canal system with bioceramic sealers should be associated with bioceramic gutta percha cones.


Gutta-Percha , Root Canal Filling Materials , Gutta-Percha/chemistry , Root Canal Filling Materials/chemistry , Epoxy Resins/chemistry , Dental Pulp Cavity , Dental Cements , Root Canal Obturation , Materials Testing
...