RESUMEN
Various equipment, mainly manual knapsack sprayers, are used to apply agrochemicals by smallholder farmers. They are highlighted by their versatility of use and mainly by their low cost for farmers. Few operator-related studies were reported in the literature regarding the effort required to operate the knapsack sprayer lever. Knapsack sprayers were evaluated regarding the effort required to move their hand levers, reach and maintain the 300 kPa pressure, and return to the initial position. The objective of this study was to evaluate the operators effort to operate the hand lever using the "Super magro" biofertilizer as fluid. It was concluded that all knapsack sprayers are within the Consolidation of Labor Laws (CLT) standards regarding the effort required to operate the hand lever. However, restrictions have been reported in some manual knapsack sprayers regarding international standards.(AU)
Existem diversos equipamentos utilizados na aplicação de agrotóxicos em propriedades familiares, principalmente os pulverizadores costais manuais. Estes ganham destaque pela sua versatilidade de uso e, principalmente, o baixo custo para o produtor rural. Na bibliografia foi constatado poucos estudos relacionados ao operador, quando analisado o seu esforço ao acionar a alavanca do pulverizador costal. Os pulverizadores costais foram avaliados quanto aos esforços necessários ao deslocamento da alavanca: para atingir a pressão de 300 kPa, na manutenção desta e em seu retorno para a posição inicial. Este estudo teve como objetivo avaliar os esforços do operador ao acionar a alavanca utilizando como fluido o biofertilizante composto Super Magro. Conclui-se, no que tange ao esforço para acionamento da alavanca, que todos os pulverizadores estão dentro das normas da CLT (Consolidação das Leis Trabalhistas), porém existem restrições a alguns pulverizadores costais manuais em relação às normas internacionais.(AU)
Asunto(s)
Humanos , Agroquímicos , Ergonomía/normas , Seguridad de Equipos/normas , Esfuerzo Físico , Legislación LaboralRESUMEN
OBJETIVES: To identify and analyze the scientific evidence regarding the occurrence of Medical Device-Related Pressure Injuries, considering the development sites; and to describe the devices of risk and the measures of prevention and treatment. METHOD: Integrative, search-based review: CINAHL, PubMed, Wiley InterScience, Scopus, and Web Of Science. The terms "pressure ulcer" and "medical devices" were used, including original articles and case studies published between 2010 and 2015. Nine studies were selected. RESULTS: Posterior cervical region and nose had the highest injury frequencies, respectively, 66.0% and 40.0%. Eleven risk devices were identified, with emphasis on Non-Invasive Ventilation masks and orotracheal tube. For prevention and treatment emerged recommendations specific to the device employed and general measures. CONCLUSION: Medical Device-Related Pressure Injuries are frequent problems, however, they can be prevented and treated based on the recommendations of the articles raised in this review.
Asunto(s)
Seguridad de Equipos/normas , Úlcera por Presión/etiología , HumanosRESUMEN
ABSTRACT Objetives: To identify and analyze the scientific evidence regarding the occurrence of Medical Device-Related Pressure Injuries, considering the development sites; and to describe the devices of risk and the measures of prevention and treatment. Method: Integrative, search-based review: CINAHL, PubMed, Wiley InterScience, Scopus, and Web Of Science. The terms "pressure ulcer" and "medical devices" were used, including original articles and case studies published between 2010 and 2015. Nine studies were selected. Results: Posterior cervical region and nose had the highest injury frequencies, respectively, 66.0% and 40.0%. Eleven risk devices were identified, with emphasis on Non-Invasive Ventilation masks and orotracheal tube. For prevention and treatment emerged recommendations specific to the device employed and general measures. Conclusion: Medical Device-Related Pressure Injuries are frequent problems, however, they can be prevented and treated based on the recommendations of the articles raised in this review.
RESUMEN Objetivo: Identificar y analizar las pruebas científicas sobre la ocurrencia de lesiones por presión relacionadas con dispositivos médicos, considerando los sitios de desarrollo; y describir los dispositivos de riesgo y las medidas de prevención y tratamiento. Método: Revisión Integrativa, con búsqueda en las bases: CINAHL, PubMed, Wiley Interscience, Scopus y Web of Science. Se utilizaron los términos "pressure ulcer" y "medical devices", incluidos los artículos originales y los estudios de caso, publicados entre 2010 y 2015. Se seleccionaron nueve estudios. Resultados: La región y la nariz cervicales posteriores obtuvieron las frecuencias más altas de lesiones, respectivamente, 66,0% y 40,0%. Se identificaron once dispositivos de riesgo, destacando las máscaras de ventilación no invasiva y el tubo orotraqueal. Para la prevención y el tratamiento surgieron recomendaciones específicas para el dispositivo empleado y las medidas generales. Conclusión: Las Lesiones por Presión Relacionadas a Dispositivos Médicos son problemas frecuentes, sin embargo, pueden ser prevenidas y tratadas con base en las recomendaciones de los artículos levantados en esta revisión.
RESUMO Objetivo: Identificar e analisar as evidências científicas quanto à ocorrência de Lesões por Pressão Relacionadas a Dispositivos Médicos, considerando os locais de desenvolvimento; e descrever os dispositivos de risco e as medidas de prevenção e tratamento. Método: Revisão integrativa, com busca nas bases: CINAHL, PubMed, Wiley InterScience, Scopus e Web Of Science. Utilizou-se os termos "pressure ulcer" e "medical devices", sendo incluídos artigos originais e estudos de caso, publicados entre 2010 e 2015. Foram selecionados nove estudos. Resultados: Região cervical posterior e o nariz obtiveram as frequências mais elevadas de lesões, respectivamente, 66,0% e 40,0%. Identificaram-se onze dispositivos de risco, destacando-se as máscaras de Ventilação Não Invasiva e o tubo orotraqueal. Para prevenção e tratamento emergiram recomendações específicas ao dispositivo empregado e medidas gerais. Conclusão: As Lesões por Pressão Relacionadas a Dispositivos Médicos são problemas frequentes, todavia, podem ser prevenidas e tratadas com base nas recomendações dos artigos levantados nesta revisão.
Asunto(s)
Humanos , Úlcera por Presión/etiología , Seguridad de Equipos/normasRESUMEN
Safety challenges related to the use of medical equipment were investigated during the training of nurse anaesthetists in Haiti, using a systems approach to Human Factors and Ergonomics (HFE). The Observable Performance Obstacles tool, based on the Systems Engineering Initiative for Patient Safety (SEIPS) model, was used in combination with exploratory observations during 13 surgical procedures, to identify performance obstacles created by the systemic interrelationships of medical equipment. The identification of performance obstacles is an effective way to study the accumulation of latent factors and risk hazards, and understand its implications in practice and behaviour of healthcare practitioners. In total, 123 performance obstacles were identified, of which the majority was related to environmental and organizational aspects. These findings show how the performance of nurse anaesthetists and their relation to medical equipment is continuously affected by more than user-related aspects. The contribution of systemic performance obstacles and coping strategies to enrich system design interventions and improve healthcare system is highlighted. In addition, methodological challenges of HFE research in low-resource settings related to professional culture and habits, and the potential of community ergonomics as a problem-managing approach are described.
Asunto(s)
Anestesiología/instrumentación , Anestesiología/normas , Países en Desarrollo , Seguridad de Equipos , Ergonomía , Seguridad del Paciente , Seguridad de Equipos/normas , Haití , Humanos , Sistemas Hombre-Máquina , Enfermeras Anestesistas/educación , Evaluación de Procesos, Atención de Salud , Análisis y Desempeño de TareasRESUMEN
To date, only one research study has evaluated how scooters respond to static and dynamic stability. However, no other studies have evaluated how scooters respond to adverse conditions and how they perform in all standard tests. A selection of 12 three-wheeled scooters was tested according to American National Standards Institute/Rehabilitation Engineering and Assistive Technology Society of North America (ANSI/ RESNA) wheelchair standards. Scooter models included the Victory, Gogo, Golden Companion (GC) I, and GC II. Victory and GC II were the most stable scooters. The Gogo scooters were the least dynamically stable. Five scooters (3 Gogo, 1 GC I, 1 GC II) failed the environmental condition tests. All GC I and II scooters failed parts of the power and control system tests. All scooters passed static and impact tests; however, all Gogo scooters and one GC II scooter had structural or motor failure during durability tests. The scooter models' survival life ranged from 62,512 to 1,178,230 cycles out of the 400,000 needed to pass the test. Tiller failures (typically tiller tube snapping) occurred with an average of 1,483 N force applied to the tiller structure. Our results indicate that these commercially available devices may not meet ANSI/RESNA standards. In addition, the tiller test should be conducted with scooters to further ensure their safety and durability and should use a test dummy with weight capacity according to the mobility device capacity.
Asunto(s)
Silla de Ruedas/normas , Suministros de Energía Eléctrica/normas , Diseño de Equipo/normas , Análisis de Falla de Equipo , Seguridad de Equipos/normas , Humanos , Ensayo de Materiales , Tiempo (Meteorología)RESUMEN
Introdução: Os ressuscitadores auto-infláveis devem funcionar eficazmente com fluxos de 35 L/min O2 , pois altos fluxos podem alterar o seu funcionamento. O objetivo deste trabalho é estudar a eficácia de funcionamento da válvula do paciente de RMAI para adultos fabricados e/ou comercializados no Brasil que recebem fluxos de O2 no interior da unidade compressível e dos RMAI que recebem fluxo de O2 externo à unidade compressível, sob fluxo de 35L/min. Métodos: Um fluxômetro foi acoplado ao RMAI e este conectado ao TRACER 5 e ao pulmão-teste. Nove RMAI, dois com entrada de fluxo no interior da unidade compressível e sete com entrada de fluxo externa à unidade recebendo 35L/min O2 foram manipulados. Resultados: Os RMAI com fluxo no interior da unidade compressível ofertaram volume corrente de 1500(150) e 1533(155) ml e pressão de pico de 40(5) cm H2 O (p>0,05). Esta situação não ocorreu nos outros sete RMAI em que o fluxo de O2 é externo à unidade compressível, pois ofertaram volume corrente de 750(0,8), 760(0,7), 720(0,6), 750(0,6), 740(0,5), 760(0,6), 730(0,7)ml (p>0,05) e pressão de pico de 16,1(0,3), 17,3(0,3), 15,1(0,3), 15,4(0,2), 16,3(0,3), 16,1(0,2) e 15,6(0,2)cmH2O (p>0,05). Conclusão: Os RMAI que recebem fluxo de O2 no interior da unidade compressível tiveram a válvula do paciente presas em posição de inspiração quando receberam fluxo de O2 a 35 L/min e apresentaram valores altos de pressão de pico e de volume corrente. Esta situação não ocorreu nos modelos em que a entrada do fluxo de O2 é externa à unidade compressível (AU)
Introduction: Self-inflating manual resuscitators (SIMR) must work effectively with O2 flows of 35 L/min, since higher flows can change its operation. The aim of this work is to investigate the effectiveness of function of the patient valve of SIMRs for adults manufactured and/or marketed in Brazil that receive O2 flows inside the compressible unit and SIMRs that receive O2 flows outside the compressible unit, at a flow of 35L/min. Methods: A flowmeter was attached to the SIMR, which was connected to TRACER 5 and the test lung. Nine SIMR, two with inflow inside the compressible unit and seven with inflow outside the unit, receiving 35L/min of O2 were manipulated. Results: The SIMR with flow inside the compressible unit delivered tidal volumes of 1500 (150) and 1533 (155) ml and peak pressure of 40 (5) cm H2 O (p> 0.05). This situation did not occur in the other seven SIMRs, where the O2 flow to the unit is external to the compressible unit as they offered tidal volumes of 750 (0.8) 760 (0.7) 720 (0.6), 750 (0; 6), 740 (0.5) 760 (0.6) 730 (0.7) ml (p> 0.05) and peak pressures of 16.1 (0.3) 17.3 (0 3), 15.1 (0.3) 15.4 (0.2) 16.3 (0.3) 16.1 (0.2) and 15.6 (0.2) cmH2 O (p> 0.05). Conclusion: The SIMR receiving O2 flow inside the compressible unit had the patient valve stuck in the inspiratory position when they received O2 flow at 35 L/min and showed high values of peak pressure and tidal volume. This situation did not occur in the models in which the O2 inflow is external to the compressible unit (AU)
Asunto(s)
Humanos , Adulto , Respiración Artificial/instrumentación , Ventiladores Mecánicos/normas , Oxígeno/administración & dosificación , Respiración Artificial/normas , Ensayo de Materiales , Seguridad de Equipos/normas , Estudios de Evaluación como AsuntoRESUMEN
Esta pesquisa objetiva recomendar especificações que os analisadores de desfibriladores e cardioversores devam apresentar, tais como: erro máximo de medição, resolução, condições de operação e recursos desejáveis. As recomendações apresentadas baseiam-se nos quesitos demandados para a realização dos ensaios previstos pelas normas NBR IEC 60601-2-4:2005 e ANSI/AAMI DF80:2003. Uma avaliação das especificações fornecidas de quatro analisadores importados (Fluke QED6, Fluke Impulse 7000, MTK-Biomed Delta 3000 MKII e NETECH Delta 3000) e dois analisadores nacionais (Transmai JM-01 e Ourox JAU-100) também foi realizada, tendo encontrado diversas falhas de especificações em todos os analisadores. Estas falhas vão desde o não fornecimento de dados a condições aquém das desejáveis para um analisador de desfibriladores e cardioversores. Os problemas mais graves encontrados estão relacionados à não apresentação de especificações tais como precisão, exatidão de medição, erro máximo de medição ou outra informação que por sua vez auxiliaria na determinação do intervalo de abrangência para a medida, como a de energia pelo analisador Transmai JM-01, algo inaceitável para um instrumento de medição, incertezas elevadas e condições de operação aquém das necessárias para a realização dos ensaios determinados pelas normas NBR IEC 60601-2-4:2005 e ANSI/AAMI DF80:2003.
This study aims to recommend specifications for defibrillator and cardioverter analyzers, such as maximum permissible measurement error, resolution, operating conditions and desirable features. The recommendations are based on the test requirements from the ABNT NBR IEC 60601-2-4:2005 and ANSI/AAMI DF80:2003 standards. An evaluation of the specifications provided by four imported analyzers (Fluke QED 6, Fluke Impulse 7000, MTK-Biomed Delta 3000 MKII and NETECH Delta 3000) and two Brazilian analyzers (Transmai JM-01 and Ourox JAU-110) has also been performed, and several problems were found with specifications of those analyzers. These problems range from unsupplied data to less than desirable conditions for a defibrillator and cardioverter analyzer. The most serious problems encountered are related to the lack of specifications such as precision, accuracy, maximum permissible measurement error or other specifications that would help determine the coverage interval of the measure, an unacceptable mistake for a measurement instrument. Other problems were related to measurement error and operating conditions not complying with the requirements of the ABNT NBR IEC 60601-2-4:2005 and the ANSI/AAMI DF80:2003 standards.
Asunto(s)
Cardioversión Eléctrica/normas , Desfibriladores/normas , Equipos y Suministros de Hospitales/normas , Seguridad de Equipos/instrumentación , Seguridad de Equipos/métodos , Seguridad de Equipos/normas , Análisis de Falla de Equipo/instrumentación , Análisis de Falla de Equipo/normas , Control de Calidad , Falla de Equipo , Estándares de ReferenciaRESUMEN
La presente publicación desarrolla la metodología de estandarización del proceso de implementación de la lista de verificación de la seguridad de la cirugía en los establecimientos de salud, a fin de evitar la ocurrencia de eventos adversos durante las intervenciones quirúrgicas; pretendiendo reforzar las prácticas de seguridad establecidas y fomentar la comunicación y el trabajo en equipo entre las disciplinas clínicas para mejorar la seguridad de sus operaciones y reducir el número de complicaciones y de defunciones quirúrgicas innecesarias ya que su uso permanente se asocia a una reducción significativa de las tasas de complicaciones y muertes en diversos hospitales y entornos y a un mejor cumplimiento de las normas de atención básicas(AU)
Asunto(s)
Cirugía General/organización & administración , Atención a la Salud/normas , Calidad de la Atención de Salud , Seguridad de Equipos/normas , Medidas de Seguridad , Gestión de la Calidad Total , Estándar de Identidad y Calidad de Productos y Servicios , Sistemas de Información en Quirófanos , Procedimientos Quirúrgicos Ambulatorios , Manuales y Guías para la Gestión de la Investigación , PerúRESUMEN
La presente publicación desarrolla la metodología de estandarización del proceso de implementación de la lista de verificación de la seguridad de la cirugía en los establecimientos de salud, a fin de evitar la ocurrencia de eventos adversos durante las intervenciones quirúrgicas; pretendiendo reforzar las prácticas de seguridad establecidas y fomentar la comunicación y el trabajo en equipo entre las disciplinas clínicas para mejorar la seguridad de sus operaciones y reducir el número de complicaciones y de defunciones quirúrgicas innecesarias ya que su uso permanente se asocia a una reducción significativa de las tasas de complicaciones y muertes en diversos hospitales y entornos y a un mejor cumplimiento de las normas de atención básicas
Asunto(s)
Atención a la Salud/normas , Cirugía General/organización & administración , Gestión de la Calidad Total , Manuales y Guías para la Gestión de la Investigación , Medidas de Seguridad , Estándar de Identidad y Calidad de Productos y Servicios , Procedimientos Quirúrgicos Ambulatorios , Calidad de la Atención de Salud , Seguridad de Equipos/normas , Sistemas de Información en Quirófanos , PerúRESUMEN
Introdução: Apresentamos nossa experiência no estudo REMCLI-ATC (REutilization de Materiales no hospital das CLinicas-ATC), que foi desenvolvido no Setor de Hemodinâmica do Departameneto de Cardiologia do Hospital de Clínicas da Faculdade de Medicina de Montevidéu, Uruguai , entre setembro de 2001 e agosto de 2002 e entre janeiro de 2003 e dezembro de 2004. Método: Foram incluídos, prospectivamente, 100 pacientes submetidos a angioplastia transluminal coronária (ATC), nos quais se utilizou aleatoriamente material novo (grupo 1, n = 49) ou reesterilizado (grupo 2, n = 51), analisando-se uma série de variáveis que avaliaram a eficácia e a segurança de cada um dos grupos. Resultados: O sucesso clínico e angiográfico no grupo 1 foi de 100 por cento e no grupo 2, de 96 por cento (p = 0,54). Não foram observadas diferenças em relação ao número de cateteres-guia e balões utilizados na ATC entre os grupos. O volume de contraste e os tempos de radioscopia e do procedimento também não apresentaram diferenças. As complicações maiores ocorreram somente no grupo 2 (0 por cento vs. 3,9 por cento; p = 0,17) e as menores ocorreram em ambos os grupos (6,1 por cento e 9,8 por cento, respectivamente; p = 0,48). Conclusão: concluímos, portanto, que é técnicamente factível e seguro utilizar material reesterilizado nas ATCs, o que permitiria, uma economia considerável para países como o Uruguai, com recursos econômicos limitados.
Background: We describe our experience in the REMCLIATC (REutilización de Materiales no hospital das CLInicasATC) study, which was developed at the Hemodynamics Section of the Department of Cardiology of the Hospital de Clínicas of the Medicine School of Montevideo, Uruguay, from September 2001 to August 2002 and from January 2003 to December 2004. Methods: A hundred patients were prospectively included and treated with Percutaneous Transluminal Coronary Angioplasty (PTCA) with new (group 1, n = 49) or reprocessed (group 2, n = 51) material. Both groups were evaluated through variables that tested safety and efficacy of each strategy. Results: The clinical and angiographic success rate was 96% with reprocessed material and 100% with new material (p = 0.54). No significant differences were found between the groups regarding the number of guide catheters, guides and balloons used in the PTCA. The volume of contrast medium, radioscopy times and procedure times were also similar. Major complications were seen only in group 2 (0% vs. 3.9%, p = 0.17), while minor complications occurred in both groups (6.1% and 9.8%, respectively; p = 0.48). Conclusion: Our data showed that it is technically possible and also safe to treat patients using reprocessed material in PTCA procedures. Theoretically this would result in an important resource saving in economically limited countries like Uruguay.
Asunto(s)
Humanos , Masculino , Femenino , Adulto , Costos de Hospital , Ahorro de Costo/economía , Equipo Reutilizado/economía , Seguridad de Equipos/economía , Seguridad de Equipos/normas , Angioplastia Coronaria con Balón/métodos , Angioplastia Coronaria con BalónRESUMEN
O presente trabalho consta de uma revisão minuciosa dos métodos de calibração de hodrofones, aplicáveis tanto aos do tipo agulha quanto aos de membrana. São revistos os métodos mais utilizados, absolutos e por comparação, associados às diversas técnicas de calibração e destinadas à determinação da sensibilidade do hidrofone. Os métodos descritos são: Reciprocidade, Varredura Plana, Interferometria a laser, TDS (Time Delay Spectrometry) e da Propagação Não Linear ou da Geração de Harmônicos. É apresentado um quadro comparativo descrevendo a incerteza típica e a máxima freqüência ultra-sônica inerentes a cada um dos métodos. A calibração de hidrofones com base no Método da Reciprocidade tem incerteza típica de cerca de mais ou menos 19 por cento (1,5dB) entre 0,5 e 15 MHz. Com o Método da Varredura Plana, a incerteza é de cerca de mais ou menos 6 por cento (0,5 dB) até 5 MHz, ou mais ou menos 15 por cento (1,2 dB) até 70 MHz. Para o Método TDS, as incertezas estão em torno de mais ou menos 7 por cento (0,7 dB) até 5 MHz e de mais ou menos 14 por cento (1,1 dB) até 30 MHz. Atualmente, o método interferométrico é considerado o melhor, mas não é de largo emprego devido ao seu alto custo de implementação.
Asunto(s)
Calibración , Transductores/normas , Transductores , Ultrasonido , Control de Calidad , Estándares de Referencia , Seguridad de Equipos/métodos , Seguridad de Equipos/normasRESUMEN
Alguns problemas encontrados na certificação de equipamentos eletromédicos relacionados aos diferentes padrões de alimentação elétrica existentes no Brasil e em outros países são apresentados. Para analisá-los foi executado um conjunto de ensaios (medeições da potência de entrada, corrente de fuga para o terra, temperaturas excessivas e parâmetros de saída) em um grupo de equipamentos eletromédicos operando em diferentes padões de alimentação elétrica. Adicionalmente, foi proposto e executado um ensaio complementar de conexão à tensão errada para verificar a segurança de equipamentos com comutação manual de tensão de alimentação. Resultados com diferenças bastante significativas entre as cinco condições de alimentação utilizadas foram obtidos, demonstrando as deficiências que podem ocorrer na utilização de Memorandos de Entendimento (MoU) realizados para aproveitar certificações pré-existentes, assim como a necessidade de regulamentação complementar para o processo. Conclui-se que há necessidade de uma adaptação normativa para corrigir algumas imperfeições das normas nacionais e internacionais. Essa adaptações deveriam incluir, pelo menos: prescrições claras relativas às condições de alimentação elétrica nas quais os equipamentos devem ser ensaiados e certificados no Brasil; um ensaio adicional, como o proposto nesta pesquisa, para avaliar a segurança de equipamentos com comutação de tensão de alimentação através de chave manual; e prescrições sobre quais plugues de rede são aceitáveis para o uso no Brasil.
Asunto(s)
Equipos y Suministros de Hospitales/normas , Falla de Equipo , Medidas de Seguridad/tendencias , Medición de Riesgo/normas , Medición de Riesgo , Control de Calidad , Instalación Eléctrica/normas , Prevención de Accidentes/normas , Seguridad de Equipos/normasRESUMEN
Due to the wide variety of equipment existing in clinical areas, there is an important question: which and how often electrical safety tests most be applied to the medical equipment. There are important differences about the electrical safety, such as the electrical insulation or the hazard considering the connection between patient and electrical instrumentation. The objective of this work was to develop an Electrical Safety Priority Index for Medical Equipment(ESPIME) involving different classifications related with electrical safety, in order to provide a numeric code indicating the priority and frequency for applying the electrical safety tests to medical equipment. The index were applied to the medical equipment in critical care locations and the result,were used to defined which set of medical equipment would be the first for developing and applying electrical safety tests in a private hospital in Mexico City.
Asunto(s)
Electricidad/efectos adversos , Electrónica Médica/normas , Seguridad de Equipos/normas , HumanosRESUMEN
A limpeza dos artigos odonto-médico-hospitalares realizada por métodos manuaisaumenta o risco de acidentes com material biológico. Foram objetivos deste estudocaracterizar os acidentes envolvendo exposição a material biológico entre trabalhadores de expurgos; identificar a freqüência da subnotificação dos acidentes e descrever as medidas deprevenção adotadas. Após aprovação em comitê de ética e consentimento dos trabalhadores,os dados foram coletados mediante entrevista com 111 trabalhadores de Centros de Material e Esterilização de hospitais da cidade de Goiânia, Estado de Goiás. Evidenciou-se que (33)29,8% dos profissionais relataram ter sofrido acidentes, destes (24) 72,7% foram notificados enove (27,3%) não foram. A maioria (92,8%) não soube citar os Equipamentos de ProteçãoIndividual indicados para uso no expurgo. Os acidentes foram, predominantemente,ocasionados por objetos perfurocortantes, envolvendo membros superiores. Concluiu-se que amaioria dos profissionais não adere às medidas preventivas, o que os expõem a situações de risco que se agravam quando os acidentes não são notificados...
Asunto(s)
Humanos , Esterilización/instrumentación , Esterilización/normas , Seguridad de Equipos/normas , Seguridad de EquiposRESUMEN
Este trabalho apresenta a implementação de um protocolo para a aquisição dos parâmetros do feixe acústico de transdutores ultra-sônicos usados em medicina, baseado em normas nacionais e internacionais. O software ATUS (Avaliação de Transdutores Ultrs-Sônicos) foi desenvolvido em MATLAB (Mathworks, Natick, MA) e se apresenta como uma ferramenta amigável para visualização dos perfis do feixe (paralelo e perpendicular à face do transdutor) e para a obtenção e cálculo dos parâmetros de interesse, como intensidade acústica e características geométricas do feixe (distância focal, comprimento focal e área focal). O protocolo é aplicável ao feixe de transdutores usados tanto em diagnóstico como em fisioterapia. A interpolação de mapeamentos 2D sub-amostrados é apresentada como uma metodologia alternativa ao mapeamento 1D em diversas direções paralelas à face do transdutor, proposto pela Norma ABNT - IEC 1689 (1998)
Asunto(s)
Transductores , Diagnóstico por Computador/instrumentación , Diagnóstico por Computador/normas , Procesamiento de Imagen Asistido por Computador , Ultrasonografía , Equipo para Diagnóstico , Seguridad de Equipos/instrumentación , Seguridad de Equipos/normasRESUMEN
O objetivo deste trabalho foi avaliar as etapas da aquisiçäo das radiografias periapicais realizadas pelos cirurgiöes-dentistas da cidade do Rio de Janeiro, visando um controle de qualidade. Elaborou-se um questinonário para verificar aparelhos de raios X, filmes, materiais, técnicas e processamento empregados com 53 profissionais participando da pesquisa. Analisou-se os resultados por meio de tabelas de frequëncia absolutas e relativas. Apesar de algumas respostas satisfatórias, outras merecem atençäo, demonstrando a necessidade de uma maior divulgaçäo das normas atuais
Asunto(s)
Competencia Clínica/normas , Equipo Dental , Mantenimiento de Equipo , Protección Radiológica/instrumentación , Protección Radiológica/normas , Encuestas y Cuestionarios , Radiografía Dental/instrumentación , Radiografía Dental/normas , Seguridad de Equipos/instrumentación , Seguridad de Equipos/normasRESUMEN
É analisada a importância das normas técnicas do ponto de vista do usuário, para garantir a qualidade nos serviços de diagnóstico por imagem e a participação dos profissionais de saúde na elaboração e implantação dessas normas.