RESUMEN
A novel method for preconcentration and electrochemical detection of zinterol in bovine urine samples was developed. In order to improve the limit of detection, the surface of a screen-printed carbon electrode was modified with electrodeposited metal copper nanoparticles. The experimental electrodeposition optimization was performed using a central composite design (CCD), involving the variables: precursor concentration, potential and time applied. Copper nanoparticles were characterized by transmission electron microscopy, scanning electron microscopy, cyclic voltammetry, and energy dispersive X-ray spectroscopy. Mesoporous shuttle-like copper oxide nanoparticles were used for the preconcentration step to avoid interferences with many compounds present in the sample matrix. The optimal working conditions for the preconcentration approach were found by means of both two-level fractional factorial and CCD designs. The obtained enhancement factor for a sample volume of 30 mL was 35 fold. The calibration curve showed linearity between 0.5 and 45 ng mL(-1) and the limit of detection was 0.16 ng mL(-1). The intra and inter assay coefficients of variability were below 4% and 5%; respectively.
Asunto(s)
Agonistas Adrenérgicos beta/orina , Cobre/química , Etanolaminas/orina , Aditivos Alimentarios/análisis , Nanopartículas del Metal/química , Agonistas Adrenérgicos beta/química , Alimentación Animal , Animales , Carbono/química , Bovinos , Electroquímica , Electrodos , Etanolaminas/química , Aditivos Alimentarios/química , Inocuidad de los Alimentos , CarneRESUMEN
Formoterol is a long acting ß(2)-agonist and has proven to be a very effective bronchodilating agent. Hence it is frequently applied therapeutically for the treatment of asthma. Because ß(2)-agonists might be misused in sports for the stimulatory effects and for growth-promoting action their use is restricted. Since January 2012, formoterol is prohibited in urinary concentrations higher than 30 ng/mL. The objective of this study was to develop and validate a simple and robust ultra high performance liquid chromatographic-tandem mass spectrometric (UHPLC-MS/MS) method for the direct quantification of formoterol in urine. Sample preparation was limited to an enzymatic hydrolysis step after which 2 µL was injected in the chromatographic system. Chromatography was performed on a C(8)-column using gradient conditions. The mobile phase consisted of water/methanol (H(2)O/MeOH) both containing 0.1% acetic acid (HOAc) and 1mM ammonium acetate (NH(4)OAc). Calibration curve were constructed between 15 and 60 ng/mL. Validation data showed bias of 1.3% and imprecision of 5.4% at the threshold. Ion suppression/enhancement never exceeded 7%. Calculating measurement uncertainty showed proof of applicability of the method. Stability of formoterol was also investigated at 56 °C (accelerated stability test) at pH 1.0/5.2/7.0 and 9.5. At the physiological pH values of 5.2 and 7.0, formoterol showed good stability. At pH 1.0 and 9.5 significant degradation was observed.