1.
Cancer Biother Radiopharm ; 32(1): 33-37, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28128645

RESUMEN

Intra-arterial injection of 131I Lipiodol is an effective treatment option for primary hepatocellular carcinoma as it delivers high radiation dose to liver tumor tissue with minimal accumulation in adjacent normal tissue. The present article demonstrates design, fabrication, and utilization of a semiautomated radiosynthesis module for preparation of 131I labeled Lipiodol. The radiolabeling method was standardized for preparation of patient dose of 131I labeled Lipiodol radiochemical yield (RCY); radiochemical purity (RCP) and pharmaceutical purity of the product were determined using optimized procedures. Sterile and apyrogenic 131I labeled Lipiodol in >60% RCY could be prepared with >95% RCP. Preclinical evaluation in animals indicated retention of more than 90% of activity at 24 hours postportal vein injection. This is the first report demonstrating potential application of simple user friendly and safe semiautomated system for routine production of 131I labeled Lipiodol, which is adaptable at centralized hospital radiopharmacies. The described prototype module can be modified as per demand for preparation of other therapeutic radiopharmaceuticals.


Asunto(s)
Carcinoma Hepatocelular/radioterapia , Aceite Etiodizado/síntesis química , Radioisótopos de Yodo/uso terapéutico , Marcaje Isotópico/instrumentación , Neoplasias Hepáticas/radioterapia , Radiofármacos/síntesis química , Animales , Aceite Etiodizado/farmacología , Aceite Etiodizado/uso terapéutico , Humanos , Inyecciones Intraarteriales , Radiofármacos/farmacología , Radiofármacos/uso terapéutico
2.
Nucl Med Commun ; 33(2): 205-8, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22124362

RESUMEN

Rhenium-188 (188Re) is of widespread interest for treating various diseases because of its attractive physical and chemical properties. The routine preparation of therapeutic doses of 188Re-labelled tracers can result in significant radiation exposure to the operator. We studied the impact of automating the preparation of 188Re-Lipiodol on the radiochemist's exposure, as well as the importance of the model of syringe shielding. To monitor radiation exposure continuously readable electronic personal dosimeters were used. Thermoluminescence dosimeters were fixed to the probable most exposed fingers of the radiochemist during preparation of the radiotracer and during the syringing. Dose rates were measured using a Babyline. Automation of the synthesis reduced personal dose equivalents from 2.60±4.35 to 1.61±1.20 µSv/GBq [Hp(10)] and from 38.37±55.28 to 21.84±16.14 µSv/GBq [Hp(0.07)]. Dose to the extremities was also reduced (-80% for the right hand; -58% for the left one). The Lemer-Pax PSWG syringe shield led to a slightly lower dose to the hands compared with the Medisystem (1.1±0.27 vs. 1.34±0.6 mSv/GBq for the right finger). Automation of the synthesis leads to a significant decrease in radiation exposure to the operator. The Lemer-Pax PSWG syringe shield provides better hand protection than the smaller Medisystem Mediclic.


Asunto(s)
Partículas beta/efectos adversos , Exposición Profesional/prevención & control , Equipos de Seguridad , Traumatismos por Radiación/prevención & control , Protección Radiológica/instrumentación , Antineoplásicos/síntesis química , Antineoplásicos/efectos de la radiación , Automatización , Carcinoma Hepatocelular/radioterapia , Aceite Etiodizado/síntesis química , Dedos/efectos de la radiación , Humanos , Neoplasias Hepáticas/radioterapia , Radioisótopos/efectos de la radiación , Renio/efectos de la radiación