Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 4 de 4
1.
Plant J ; 103(3): 1189-1204, 2020 08.
Article En | MEDLINE | ID: mdl-32369642

Tomato (Solanum lycopersicum L.) has become a popular model for genetic studies of fruit flavor in the last two decades. In this article we present a study of tomato fruit flavor, including an analysis of the genetic, metabolic and sensorial variation of a collection of contemporary commercial glasshouse tomato cultivars, followed by a validation of the associations found by quantitative trait locus (QTL) analysis of representative biparental segregating populations. This led to the identification of the major sensorial and chemical components determining fruit flavor variation and detection of the underlying QTLs. The high representation of QTL haplotypes in the breeders' germplasm suggests that there is great potential for applying these QTLs in current breeding programs aimed at improving tomato flavor. A QTL on chromosome 4 was found to affect the levels of the phenylalanine-derived volatiles (PHEVs) 2-phenylethanol, phenylacetaldehyde and 1-nitro-2-phenylethane. Fruits of near-isogenic lines contrasting for this locus and in the composition of PHEVs significantly differed in the perception of fruity and rose-hip-like aroma. The PHEV locus was fine mapped, which allowed for the identification of FLORAL4 as a candidate gene for PHEV regulation. Using a gene-editing-based (CRISPR-CAS9) reverse-genetics approach, FLORAL4 was demonstrated to be the key factor in this QTL affecting PHEV accumulation in tomato fruit.


Borates/metabolism , Fructose/analogs & derivatives , Genes, Plant/genetics , Quantitative Trait Loci/genetics , Solanum lycopersicum/genetics , Borates/standards , CRISPR-Associated Protein 9 , CRISPR-Cas Systems , Chromosome Mapping , Chromosomes, Plant/genetics , Food Quality , Fructose/metabolism , Fructose/standards , Gene Editing , Genes, Plant/physiology , Solanum lycopersicum/metabolism , Solanum lycopersicum/standards , Phenylalanine/metabolism , Quantitative Trait, Heritable , Volatile Organic Compounds/metabolism
2.
Clin Ther ; 30(12): 2452-60, 2008 Dec.
Article En | MEDLINE | ID: mdl-19167603

OBJECTIVE: The aim of this study was to describe persistence with migraine prophylactic treatment and acute migraine medication utilization in patients prescribed migraine prophylaxis. METHODS: For this retrospective cohort study, the Health Core Integrated Research Database provided pharmacy/medical claims data from 5 commercial health insurance plans (ie, excluding Medicare and Medicaid) on adult patients with migraine. Eligible patients had >or=1 pharmacy claim for a migraine prophylactic medication between July 1, 2000, and May 31, 2005, and >or=12 U of any combination of acute treatment (serotonin receptor agonist [triptan], ergotamine, or ergotamine combination) dispensed during the 180-day period preceding a first pharmacy claim for a prophylactic medication (index date). The prophylactic medication identified at index date was used for categorizing patients into 1 of 4 cohorts: amitriptyline, propranolol/timolol, divalproex sodium, or topiramate (reference). Kaplan-Meier curves were used for evaluating unadjusted risk for discontinuation over time, and a multivariate Cox proportional hazards model was developed to analyze factors associated with discontinuation of prophylactic medication. RESULTS: A total of 12,783 patients met the inclusion criteria and were included in the analysis (amitriptyline, 3749; propranolol/timolol, 2718; divalproex sodium, 1644; and topiramate, 4672). The mean (SD) ages were not significantly different across cohorts (43.9 [11.3], 42.0 [11.1], 43.1 [11.3], and 43.9 [10.6] years, respectively). The mean duration of treatment was significantly longer (131 [184] days) with topiramate compared with amitriptyline (94 [152] days), propranolol/ timolol (119 [180] days), and divalproex sodium (109 [158] days) (P < 0.001, P = 0.005, and P<0.001,respectively). The risks for discontinuing prophylactic treatment were 23%, 6%, and 11% higher with amitriptyline, propranolol/timolol, and divalproex sodium, respectively, compared with topiramate (P<0.001, P = 0.024, and P <0.001). Patients prescribed topiramate had a higher mean consumption rate of triptans preindex; postindex, decreases in triptan use were observed in all cohorts, although the magnitude of the decrease was greatest in patients prescribed topiramate compared with the other cohorts. CONCLUSIONS: In this study, prescription of topiramate was associated with greater persistence with prophylactic treatment than the other prophylactic drugs. Furthermore, greater reductions in acute treatment utilization, particularly triptans, were observed among patients prescribed topiramate compared with the other prophylactic cohorts.


Drug Utilization Review/statistics & numerical data , Managed Care Programs/statistics & numerical data , Medication Adherence/statistics & numerical data , Migraine Disorders/prevention & control , Adult , Age Factors , Amitriptyline/therapeutic use , Cohort Studies , Databases, Factual/statistics & numerical data , Dose-Response Relationship, Drug , Drug Prescriptions/statistics & numerical data , Drug Therapy, Combination , Drug Utilization Review/methods , Female , Fructose/analogs & derivatives , Fructose/standards , Fructose/therapeutic use , Humans , Kaplan-Meier Estimate , Male , Managed Care Programs/organization & administration , Middle Aged , Migraine Disorders/drug therapy , Proportional Hazards Models , Propranolol/therapeutic use , Retrospective Studies , Sex Factors , Time Factors , Timolol/therapeutic use , Topiramate , Valproic Acid/therapeutic use
3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 25(7): 1049-52, 2005 Jul.
Article Zh | MEDLINE | ID: mdl-16241052

Near infrared spectrophotometry was used to determine the concentrations of one, two and three-component sugar aqueous solutions. However, this method was always applied to dry or low moisture products and was not practicable for fresh fruits and vegetables because of the strong absorption of water in near infrared region. In this paper, the authors applied NIR method to aqueous solutions and discussed how to enhance the sensitivity. In aqueous solution systems, concentration of each individual sugar was in range of 0.01-0.25 mol x L(-1). Different calibrations and predicted results were gotten and compared to each other when full spectra or significant spectra regions were considered. By selecting relevant spectra regions due to important structural information to overcome the disturbance from absorption of water, calculations could be optimized and predicted results of concentrations were more accurate regarding the standard error of calibration (SEC) and standard error of prediction (SEP).


Carbohydrates/analysis , Spectroscopy, Near-Infrared , Calibration , Carbohydrates/chemistry , Carbohydrates/standards , Fructose/analysis , Fructose/chemistry , Fructose/standards , Glucose/analysis , Glucose/chemistry , Glucose/standards , Reference Standards , Reproducibility of Results , Solutions/analysis , Solutions/chemistry , Sucrose/analysis , Sucrose/chemistry , Sucrose/standards , Water/chemistry
4.
J Chromatogr B Analyt Technol Biomed Life Sci ; 824(1-2): 36-44, 2005 Sep 25.
Article En | MEDLINE | ID: mdl-16061433

Evaluation of different extraction methods for quantification of endogenous sorbitol and fructose in human red blood cells (RBCs) and matrix effects in ESI and APCI showed that protein-precipitation followed by mixed-mode solid-phase extraction was more effective extraction method and APCI more effective ionization method. Then the LC/APCI-MS/MS method was fully validated and successfully applied to analysis of clinical RBC samples. The concentrations of endogenous sorbitol and fructose were determined using calibration curves employing sorbitiol-13C6 and fructose-13C6 as surrogate analytes. The method has provided excellent intra- and inter-assay precision and accuracy with a linear range of 50.0-10,000 ng/mL (correlation coefficient >0.999) for sorbitol-13C6 and 250-50000 ng/mL (correlation coefficient >0.999) for fructose-13C6 in human RBCs.


Chromatography, Liquid/methods , Erythrocytes/chemistry , Fructose/blood , Sorbitol/blood , Spectrometry, Mass, Electrospray Ionization/methods , Atmospheric Pressure , Chromatography, Liquid/instrumentation , Fructose/chemistry , Fructose/standards , Humans , Reference Standards , Reproducibility of Results , Sorbitol/chemistry , Sorbitol/standards , Spectrometry, Mass, Electrospray Ionization/instrumentation , Stereoisomerism
...