Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.788
Filtrar
2.
G Ital Nefrol ; 41(3)2024 06 28.
Artículo en Italiano | MEDLINE | ID: mdl-38943331

RESUMEN

Introduction and aim of the study. The centralized preparation and distribution system of acidic concentrate represents a true innovation in hemodialysis, when compared to acid bags, in terms of convenience and eco-sustainability. The aim of this study is to compare the use of traditional acid bags with the centralized distribution system of acidic concentrate, with particular attention to differences in terms of eco-sustainability and convenience. Methods. At the Nephrology Dialysis and Renal Transplantation Unit of the University Hospital of Modena was installed the Granumix system® (Fresenius Medical Care, Bad Homburg, Germany). Data collected before the introduction of the Granumix® system (including the used acid bags, boxes and pallets used for their packaging, liters of acid solution used and kilograms of waste generated from wood, plastic, cardboard and residual acid solution) were compared with those collected after the implementation of the Granumix® system. Factors such as material consumption, volume of waste generated, unused and wasted products, time required for dialysis session preparation and nurses' satisfaction were analyzed to document which system was more environmentally sustainable. Results. Data collected in 2019 at our Dialysis Center showed a consumption of 30,000 acid bags, which generated over 20,000 kg of waste from wood, plastic and cardboard, and approximately 12,000 liters of residual acid solution to be disposed of, with a handling weight by operators reaching nearly 160,000 kg. The use of the centralized distribution system of acidic concentrate resulted in a significant reduction in waste generated (2,642 kg vs 13,617 kg), residual acid solution to be disposed of (2,351 liters vs 12,100 liters) and weights handled by operators (71,522 kg vs 158,117 kg). Conclusions. The acidic concentrate appears to be better suited to the sustainability challenge that dialysis must faces today, particularly due to the significant increase in the number of patients, which leads to a higher number of treatments and, therefore, a growing demand for eco-sustainable products.


Asunto(s)
Diálisis Renal , Humanos , Italia , Ácidos , Soluciones para Hemodiálisis , Conservación de los Recursos Naturales
3.
Artif Organs ; 48(7): 704-712, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38716639

RESUMEN

BACKGROUND: Regional anticoagulation in hemodialysis avoids the use of heparin, which is responsible for both hemorrhagic and non-hemorrhagic complications. Typically, blood is decalcified by injecting citrate into the arterial line of the extracorporeal circuit. Calcium-free dialysate improves anticoagulation efficacy but requires injection of a calcium-containing solution into the venous line and strict monitoring of blood calcium levels. Recent improvements have made regional anticoagulation with calcium-free dialysate safer and easier. OBSERVATIONS: (1) Adjusting the calcium injection rate to ionic dialysance avoids the risk of dyscalcemia, thus making unnecessary the monitoring of blood calcium levels. This adjustment could be carried out automatically by the hemodialysis monitor. (2) As calcium-free dialysate reduces the amount of citrate required, this can be supplied by dialysate obtained from currently available concentrates containing citric acid. This avoids the need for citrate injection and the risk of citrate overload. (3) Calcium-free dialysate no longer needs the dialysate acidification required for avoiding calcium carbonate precipitation in bicarbonate-containing dialysate. CONCLUSIONS: Regional anticoagulation with calcium-free dialysate enables an acid- and heparin-free procedure that is more biocompatible and environmentally friendly than conventional bicarbonate hemodialysis. The availability of specific acid-free concentrates and adapted hemodialysis monitors is required to extend this procedure to maintenance hemodialysis.


Asunto(s)
Anticoagulantes , Calcio , Diálisis Renal , Humanos , Diálisis Renal/métodos , Diálisis Renal/instrumentación , Anticoagulantes/administración & dosificación , Soluciones para Diálisis/química , Ácido Cítrico/administración & dosificación , Ácido Cítrico/química , Coagulación Sanguínea/efectos de los fármacos , Soluciones para Hemodiálisis/química
4.
Int Urol Nephrol ; 56(7): 2313-2323, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38446246

RESUMEN

PURPOSE: The present systematic review and meta-analysis aimed at evaluating the effect of low dialysate sodium concentration on interdialytic weight gain (IDWG) in chronic hemodialysis patients. METHODS: Studies were eligible for inclusion if they were English language papers published in a peer-reviewed journal and met the following inclusion criteria: (1) studies in adult patients (over 18 years of age), (2) included patients on chronic hemodialysis since at least 6 months; (3) compared standard (138-140 mmol/l) or high (> 140 mmol/l) dialysate sodium concentration with low (< 138 mmol/l) dialysate sodium concentration; (4) Included one outcome of interest: interdialytic weight gain. Medline, PubMed, Web of Science, and the Cochrane Library were searched for the quality of reporting for each study was performed using the Quality Assessment Tool of Controlled Intervention Studies of the National Institutes of Health. The quality of reporting of each cross-over study was performed using the Revised Cochrane Risk of Bias (RoB) tool for cross-over trials as proposed by Ding et al. RESULTS: Nineteen studies (710 patients) were included in the analysis: 15 were cross-over and 4 parallel randomized controlled studies. In cross-over studies, pooled analysis revealed that dialysate sodium concentration reduced IDWG with a pooled MD of - 0.40 kg (95% CI - 0.50 to - 0.30; p < 0.001). The systematic review of four parallel, randomized, studies revealed that the use of a low dialysate sodium concentration was associated with a significant reduction of the IDWG in two studies, sustained and almost significant (p = 0.05) reduction in one study, and not significant reduction in one study. CONCLUSION: Low dialysate sodium concentration reduces the IDWG in prevalent patients on chronic hemodialysis.


Asunto(s)
Soluciones para Diálisis , Diálisis Renal , Sodio , Aumento de Peso , Humanos , Sodio/análisis , Fallo Renal Crónico/terapia , Soluciones para Hemodiálisis/química
6.
Clin Exp Nephrol ; 28(6): 557-570, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38396314

RESUMEN

BACKGROUND: The optimal dialysate calcium (Ca) concentration for patients undergoing hemodialysis remains inconclusive, particularly concerning cardiovascular protection. METHODS: We conducted a systematic review of 19 randomized controlled trials (RCTs) and a meta-analysis of eight RCTs to determine the optimal dialysate Ca concentration for cardiovascular protection. We compared outcomes in patients receiving maintenance hemodialysis treated with either a low-Ca dialysate (LCD) (1.125 or 1.25 mmol/L) or a high-Ca dialysate (HCD) (1.5 or 1.75 mmol/L). The outcomes were coronary artery calcification score (CACS), all-cause and cardiovascular death, cardiovascular function and structure, and serum biochemical parameters. RESULTS: There was no significant difference between LCD and HCD concerning CACS (standardized mean difference [SMD] = -0.16, 95% confidence interval [CI]: [-0.38, 0.07]), the risk of all-cause death, and cardiovascular death in patients treated with chronic maintenance hemodialysis. Conversely, LCD was associated with a significantly lower intima-media thickness (SMD = -0.49, 95% CI [-0.94, -0.05]) and pulse wave velocity than HCD (SMD = -0.86, 95% CI [-1.21, -0.51]). Furthermore, LCD significantly decreased serum Ca levels (mean difference [MD] = 0.52 mg/dL, 95% CI [0.19, 0.85]) and increased serum parathyroid hormone levels (MD = 44.8 pg/mL, 95% CI [16.2, 73.3]) compared with HCD. Notably, most RCTs examined in our analysis did not include patients receiving calcimimetics. CONCLUSIONS: Our meta-analysis showed no significant differences in cardiovascular calcification and death between LCD and HCD and revealed a paucity of RCTs on dialysate Ca concentrations, including those involving patients on calcimimetics, indicating the urgent need for further studies.


Asunto(s)
Calcio , Enfermedades Cardiovasculares , Soluciones para Hemodiálisis , Diálisis Renal , Humanos , Diálisis Renal/efectos adversos , Calcio/sangre , Enfermedades Cardiovasculares/mortalidad , Enfermedades Cardiovasculares/prevención & control , Soluciones para Hemodiálisis/efectos adversos , Soluciones para Hemodiálisis/química , Ensayos Clínicos Controlados Aleatorios como Asunto , Hormona Paratiroidea/sangre , Persona de Mediana Edad , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/prevención & control , Resultado del Tratamiento
7.
Nefrología (Madrid) ; 43(6): 750-756, nov.- dec. 2023. graf, tab
Artículo en Español | IBECS | ID: ibc-228013

RESUMEN

Introducción El gradiente de sodio durante las sesiones es uno de los factores clave en el balance de este ion en los pacientes en hemodiálisis; sin embargo, hasta la aparición de los nuevos monitores con módulos de sodio, las diferencias entre el sodio prescrito y el medido han sido poco estudiadas. El objetivo del presente estudio fue comparar el impacto del cambio del monitor 5008 Cordiax al nuevo monitor 6008 Cordiax sobre los resultados de la conductividad real medida, del sodio plasmático inicial y final. Material y métodos Se incluyeron 106 pacientes en hemodiálisis. Cada paciente recibió dos sesiones de diálisis en las que solo se varió el monitor. Las variables recogidas fueron: el concentrado, sodio y bicarbonato prescritos, conductividad real, sodio plasmático inicial y final medidos por dialisancia iónica y se calculó el cambio de la concentración de sodio plasmático durante el tratamiento o delta de sodio (ΔPNa). Resultados El cambio de monitor de diálisis mostró pequeñas diferencias, aunque significativas, en el sodio plasmático inicial (138,14 mmol/L con 5008 vs. 138,81 mmol/L con 6008) y final (139,58 mmol/L vs. 140,97 mmol/L), así como en la conductividad real obtenida (13,97 vs. 14,10 mS/cm). El ΔPNa también aumento significativamente. Conclusión El cambio de monitor 5008 a 6008 se asocia a un aumento en la conductividad, un sodio plasmático más elevado y un incremento en el ΔPNa. El conocer y confirmar este cambio permitirá individualizar la prescripción de sodio, evitar posibles efectos indeseables y podría ser el estudio preliminar para explorar el nuevo biosensor de control de sodio incorporado en la nueva generación de monitores (AU)


Introduction The sodium gradient during hemodialysis sessions is one of the key factors in sodium balance in patients with dialysis-dependent chronic kidney disease; however, until the appearance of the new monitors with sodium modules, the differences between prescribed and measured sodium have been understudied. The present study aimed to compare the impact on the measured conductivity and the initial and final plasma sodium after changing the 5008 Cordiax to the new 6008 Cordiax monitor. Material and methods 106 patients on hemodialysis were included. Each patient underwent 2 dialysis sessions in which only the monitor was varied. The variables collected were dialysate, sodium and bicarbonate prescribed, real conductivity, initial and final plasma sodium measured, and the calculated sodium gradient (ΔPNa). Results The change of dialysis monitor showed small but statistically significant differences in the initial (138.14 mmol/L with 5008 vs. 138.81 mmol/L with 6008) and final plasma sodium (139.58 mmol/L vs. 140.97 mmol/L), as well as in the actual conductivity obtained (13.97 vs. 14.1 mS/cm). The ΔPNa also increased significantly. Conclusión The change from 5008 to 6008 monitor is associated with increased conductivity, leading the patient to end the sessions with higher plasma sodium and ΔPNa. Knowing and confirming this change will allow us to individualize the sodium prescription and avoid possible undesirable effects. It could be the preliminary study to explore the new sodium biosensor incorporated into the new generation of monitors (AU)


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Soluciones para Hemodiálisis/química , Insuficiencia Renal Crónica/terapia , Sodio/sangre , Sodio/metabolismo , Técnicas Biosensibles
8.
Ther Apher Dial ; 27(6): 1053-1063, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37381091

RESUMEN

Hemodialysis is considered a treatment of choice for patients with renal failure worldwide, allowing the replacement of some kidney functions by diffusion and ultrafiltration processes. Over 4 million people require some form of renal replacement therapy, with hemodialysis being the most common. During the procedure, contaminants in the water and the resulting dialysate may pass into the patient's blood and lead to toxicity. Thus, the quality of the associated dialysis solutions is a critical issue. Accordingly, the discussion of the importance of a dialysis water delivery system controlled by current standards and recommendations, with efficient monitoring methods, disinfection systems, and chemical and microbiological analysis, is crucial for improving the health outcomes of these patients. The importance of treatment, monitoring, and regulation is emphasized by presenting several case studies concerning the contamination of hemodialysis water and the adverse effects on the respective patients.


Asunto(s)
Terapia de Reemplazo Renal Continuo , Calidad del Agua , Humanos , Diálisis Renal/efectos adversos , Soluciones para Diálisis/efectos adversos , Ultrafiltración , Soluciones para Hemodiálisis/efectos adversos
9.
ACS Appl Mater Interfaces ; 15(24): 28907-28921, 2023 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-37285144

RESUMEN

In an attempt to address the significant morbidity, mortality, and economic cost associated with tunneled dialysis catheter (TDC) dysfunction, we report the development of nitric oxide-releasing dialysis catheter lock solutions. Catheter lock solutions with a range of NO payloads and release kinetics were prepared using low-molecular-weight N-diazeniumdiolate nitric oxide donors. Nitric oxide released through the catheter surface as a dissolved gas was maintained at therapeutically relevant levels for at least 72 h, supporting clinical translatability (interdialytic period). Slow, sustained NO release from the catheter surface prevented bacterial adhesion in vitro by 88.9 and 99.7% for Pseudomonas aeruginosa and Staphylococcus epidermidis, respectively, outperforming a burst NO-release profile. Furthermore, bacteria adhered to the catheter surface in vitro prior to lock solution use was reduced by 98.7 and 99.2% for P. aeruginosa and S. epidermidis, respectively, when using a slow releasing NO donor, demonstrating both preventative and treatment potential. The adhesion of proteins to the catheter surface, a process often preceding biofilm formation and thrombosis, was also lessened by 60-65% by sustained NO release. In vitro cytotoxicity of catheter extract solutions to mammalian cells was minimal, supporting the non-toxic nature of the NO-releasing lock solutions. The use of the NO-releasing lock solution in an in vivo TDC porcine model demonstrated decreased infection and thrombosis, enhanced catheter functionality, and improved outcome (i.e., likelihood of survival) as a result of catheter use.


Asunto(s)
Infecciones Relacionadas con Catéteres , Catéteres Venosos Centrales , Trombosis , Animales , Antibacterianos/uso terapéutico , Infecciones Relacionadas con Catéteres/microbiología , Soluciones para Hemodiálisis , Mamíferos , Óxido Nítrico , Diálisis Renal , Porcinos , Trombosis/tratamiento farmacológico
10.
Perfusion ; 38(1): 178-185, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-34541941

RESUMEN

OBJECTIVE: To investigate the effects of glucose-free and glucose-containing dialysates during dialysis in maintenance hemodialysis (MHD) patients by the prospective cross-over study, and detect glucose control methods in MHD patients. METHODS: A total of 66 MHD 18-75 years old patients in our hospital from Nov. 2019 to Mar. 2020 were recruited. All patients underwent HD with 4 hours per time, three times per week. Glucose-free dialysate (glucose-free group) and then 5.55 mmol/L glucose-containing dialysate (glucose-5.55 group) were used alternately in dialysis. The demographics and parameters of pre- and post-dialysis were recorded. RESULTS: A total of 60 patients were analyzed, and 28 patients among them had type 2 diabetes. Serum glucose pre and post dialysis were 8.64 ± 4.18 mmol/L versus 5.74 ± 1.82 mmol/L (p < 0.01) in glucose-free dialysate, and 9.31 ± 4.89 mmol/L versus 7.80 ± 2.59 mmol/L (p < 0.01) in glucose-5.55 dialysate. The post-dialysis blood glucose of glucose-free group was lower than glucose-5.55 group (5.74 ± 1.82 vs 7.80 ± 2.59, p < 0.01). About 18 (30.00%) patients in glucose-free group and 1 patient (1.67%) in glucose-5.55 group whose blood glucose was lower than 4.44 mmol/L (p < 0.01). About 29 patients (48.33%) in glucose-free group and 17 patients (28.33%; p = 0.02) in glucose-5.55 group have hunger feeling. Serum sodium level in the glucose-free group was higher than that in Glucose-5.55 group (137.92 ± 1.64 vs 136.70 ± 1.64, p < 0.01). Post-dialysis blood glucose had no significant differences between patients not using diabetes-related medication (13 patients) and patients using diabetes-related medication (15 patients) in glucose-free group (7.13 ± 1.78 mmol/L vs 6.08 ± 2.84 mmol/L, p = 0.23) and glucose-5.55 group (9.22 ± 2.59 mmol/L vs 9.35 ± 2.88 mmol/L, p = 0.90). CONCLUSIONS: Glucose-free and glucose-5.55 dialysate both decrease the blood glucose post-dialysis. Dialysates containing 5.55 mmol/L glucose can reduce the incidence of hypoglycemia and lower serum sodium, but have no effect on blood pressure during dialysis. Stopping insulin and oral anti-diabetic drugs once before dialysis may not affect the control of blood glucose.


Asunto(s)
Diabetes Mellitus Tipo 2 , Fallo Renal Crónico , Adolescente , Adulto , Anciano , Humanos , Persona de Mediana Edad , Adulto Joven , Glucemia , Estudios Cruzados , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Soluciones para Diálisis/farmacología , Soluciones para Diálisis/uso terapéutico , Glucosa/farmacología , Glucosa/uso terapéutico , Soluciones para Hemodiálisis , Fallo Renal Crónico/terapia , Estudios Prospectivos , Diálisis Renal/métodos , Sodio
11.
Blood Purif ; 52(5): 401-406, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-33684920

RESUMEN

Dialysis therapy is the predominant choice for renal failure in Japan, and almost 30% of the patients with renal failure have been treated for 10 years or more. Dialysis became the standard procedure to treat renal failure nationwide in the 1980s. However, at that time, managing the increased number of patients on maintenance hemodialysis as well as operating and maintaining the newly developed advanced medical technologies at extensive numbers of clinical sites proved problematic. To help address this, the clinical engineer system was established in 1987 and certain aspects of the clinical engineers' role remain unique to Japan today. For the last 30 years, clinical engineers have worked as frontline medical personnel not only operating dialysis-related devices but also placing their hands directly on patients when providing care, routinely performing puncture, and administering drugs through the blood circuit under physicians' instructions. As part of their work, they crucially maintain the use of central dialysis fluid delivery systems (CDDSs) - also unique to Japan - which prepare and deliver a large quantity of dialysis fluid through a central circuit to individual dialysis consoles. CDDSs are widely used because they effectively alleviated the early confusion at clinical sites caused by the rapidly increasing hemodialysis population and the serious shortage in medical personnel. Moreover, clinical engineers alone have the technical ability to provide safe dialysis fluids adjusted to strict standards at clinical sites. In this review article, we focus on the crucial roles that clinical engineers have in maintaining the safety of dialysis-related medical devices and the preparation and delivery of dialysis fluid at many dialysis facilities across the country.


Asunto(s)
Diálisis Renal , Insuficiencia Renal , Humanos , Soluciones para Hemodiálisis , Japón , Soluciones para Diálisis , Administración de la Seguridad
12.
Semin Dial ; 36(1): 24-28, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35384078

RESUMEN

BACKGROUND: Hemodialysis solutions typically contain a high alkali concentration designed to counter interdialytic acidosis, but this could result in persistent alkalosis in some patients. The prevalence and significance of persistent alkalosis were therefore examined at four outpatient centers over a 10-year period. METHODS: Alkalosis was defined as a pre-dialysis serum [HCO3 ] ≥ 26 meq/L in >6 months of a 12-month period and was persistent if present in a majority of months thereafter. Control patients had a serum [HCO3 ] of 19-23 meq/L > 6 of every 12 months. Standard, citrate-containing dialysate was used in all patients without adjustment of bicarbonate concentration. RESULTS: 444 of 1271 patients had alkalosis that persisted in 73. Compared to control patients, persistently alkalotic patients were older, but gender, race, starting weight, comorbidities, and mortality did not differ. Dialysis dose was 7% greater, protein catabolic rate was 11% lower, and interdialytic weight gain was 29% lower, all p < 0.001. Persistently alkalotic patients had double the incidence of cardiac arrhythmias (p = 0.07) and a 20% greater intradialytic blood pressure decrease (p < 0.001). CONCLUSIONS: Alkalosis is common in hemodialysis patients and can be persistent, likely due to decreased protein catabolic rate and increased dialysis dose, and may have detrimental cardiovascular effects.


Asunto(s)
Alcalosis , Diálisis Renal , Humanos , Diálisis Renal/efectos adversos , Estudios Prospectivos , Soluciones para Diálisis , Soluciones para Hemodiálisis , Alcalosis/epidemiología , Alcalosis/etiología , Bicarbonatos/metabolismo
14.
Cambios rev med ; 21(2): 837, 30 Diciembre 2022. ilus, tabs.
Artículo en Español | LILACS | ID: biblio-1416043

RESUMEN

INTRODUCCIÓN. La falla hepática ya sea aguda o crónica reagudizada representa un reto para el clínico ya que sus complicaciones conllevan una gran mortalidad, esto se ve aún más complicado ya que las opciones terapéuticas son limitadas, incluso muchas veces no se puede acceder a un programa de trasplante hepático oportuno que mejore la sobrevida de estos pacientes, es así que se ha desarrollado un sistema de "diálisis" hepática conocido como sistema de recirculación de adsorbentes moleculares el cual hace un efecto de detoxificación para eliminar sustancias que generan una noxa en el cuerpo humano. OBJETIVO. Entender la utilidad del sistema recirculante molecular adsorbente en la falla hepática, conocer sus indicaciones y complicaciones. METODOLOGÍA. Se realizó una revisión de la literatura con un enfoque descriptivo, retrospectivo cualitativo no experimental, de documentos que tratan sobre la utilización del sistema MARS para tratar la falla hepática, con evidencia desde el año 2004 hasta el 2021. La revisión bibliográfica se llevó a cabo en bases de datos como Pubmed, Embase, BVS, Google Scholar y Elsevier. RESULTADOS. Se identificaron 30 artículos que cumplieron criterios de inclusión de un grupo original de 343 artículos revisados. Se ha determinado que la evidencia sobre este sistema está compuesta sobre todo por reportes de caso y son pocos los ensayos controlados aleatorizados que empleen su uso, sin embargo, se ha podido determinar que este sistema es un puente al trasplante renal mientras se estabiliza al paciente en la Unidad de Cuidados Intensivos, disminuye los marcadores de falla hepática. CONCLUSIÓN. En Latinoamérica su uso es casi nulo de ahí la necesidad de entender el mecanismo de este novedoso sistema.


INTRODUCTION. Hepatic failure, whether acute or chronic, represents a challenge for the clinician since its complications entail a great mortality, this is even more complicated since the therapeutic options are limited, even many times it is not possible to access a timely liver transplant program to improve the survival of these patients, Thus, a hepatic "dialysis" system known as molecular adsorbent recirculation system has been developed, which has a detoxification effect to eliminate substances that generate a noxa in the human body. OBJECTIVE. To understand the usefulness of the molecular adsorbent recirculating system in liver failure, to know its indications and complications. METHODOLOGY. A literature review was performed with a descriptive, retrospective qualitative non-experimental qualitative approach, of papers dealing with the use of the MARS system to treat liver failure, with evidence from 2004 to 2021. The literature review was conducted in databases such as Pubmed, Embase, BVS, Google Scholar and Elsevier. RESULTS. Thirty articles were identified that met inclusion criteria from an original group of 343 articles reviewed. It has been determined that the evidence on this system is mainly composed of case reports and there are few randomized controlled trials that employ its use, however, it has been determined that this system is a bridge to renal transplantation while the patient is stabilized in the Intensive Care Unit, decreasing the markers of liver failure. CONCLUSIONS. In Latin America its use is almost null, hence the need to understand the mechanism of this novel system.


Asunto(s)
Humanos , Masculino , Femenino , Soluciones para Hemodiálisis/química , Encefalopatía Hepática , Fallo Hepático/terapia , Adsorción , Albúminas/uso terapéutico , Unidades de Cuidados Intensivos , Fallo Hepático Agudo , Fallo Hepático , Diálisis , Albúminas , Ecuador , Hepatopatías
15.
Bioanalysis ; 14(19): 1257-1270, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36416749

RESUMEN

Aim: To develop and validate a bioanalytical method for the quantification of INCB000928 in hemodialysate. Materials & methods: Blank dialysate and phosphate-buffered saline were compared with hemodialysate for surrogate matrix selection. Direct addition of internal standard without analyte extraction and a high-performance LC-MS/MS were used for analysis. Results & conclusion: INCB000928 in hemodialysate exhibited strong nonspecific binding to polypropylene containers. In the presence of 10% isopropyl alcohol, the loss of INCB000928 was fully recovered, regardless of pre- or post-addition of the solvent. Blank dialysate and phosphate-buffered saline were determined to be appropriate surrogate matrices by using a three-way cross-comparison and were subsequently validated in the quantitative analysis of INCB000928 in hemodialysate.


Fibrodysplasia ossificans progressiva (FOP) is a very rare disease characterized by congenital malformation of the great toes and progressive heterotopic ossification. The genetic cause of FOP is mutation in the gene ALK2. INCB000928 is a novel and orally available drug that inhibits ALK2 protein activity and has been shown to prevent ossification in a laboratory mouse model of FOP. Patients with end-stage renal disease who undergo hemodialysis may require a different dose of INCB000928. This study showed that INCB000928 was heavily adsorbed by the container wall, resulting in underestimated drug levels in hemodialysate. We present a method to accurately measure INCB000928 levels in hemodialysate by using isopropyl alcohol as an antiadsorption agent and cost-effective surrogate matrix.


Asunto(s)
Miositis Osificante , Humanos , Soluciones para Hemodiálisis , Cromatografía Liquida , Receptores de Activinas Tipo I/metabolismo , Espectrometría de Masas en Tándem , Inhibidores de Proteínas Quinasas , Fosfatos
16.
Nefrología (Madrid) ; 42(4): 460-470, Julio - Agosto 2022. tab, graf
Artículo en Español | IBECS | ID: ibc-205787

RESUMEN

La hemodiálisis domiciliaria (HDD) con monitores de bajo flujo de líquido de diálisis ha ganado popularidad en los últimos años gracias a su sencillez de diseño, portabilidad y capacidad de desplazamiento. No obstante, existen dudas respecto a la adecuación que este tipo de técnica ofrece, pues utiliza monitores con baño a flujos bajos y lactato. El objetivo de este estudio fue demostrar los beneficios clínicos de la HDD con el monitor NxStage System One® introducido recientemente en España.Presentamos los resultados de un estudio observacional, retrospectivo que incluyó de manera no seleccionada a los primeros pacientes con HDD corta mediante este monitor en 12 centros en España. Se analizó la evolución clínica de 86 pacientes a 0, 6 y 12 meses, incluyendo datos relacionados con la prescripción, evolución de parámetros analíticos de dosis de diálisis, anemia, metabolismo óseo-mineral, evolución de la diuresis residual, utilización de fármacos y datos relacionados con permanencia en la técnica, y causas de salida a lo largo del seguimiento. Pudimos demostrar que este monitor proporcionó una adecuada dosis de diálisis, con tasa óptima de ultrafiltración, con mejoría de los principales marcadores bioquímicos de adecuación en diálisis. El uso de esta técnica se asoció con una disminución de antihipertensivos, captores del fósforo y agentes eritropoyéticos, observándose, además, muy buenos resultados de supervivencia tanto del paciente como de la técnica. La sencillez de este monitor unida a sus buenos resultados clínicos debería facilitar el crecimiento y utilización de la HDD, tanto en pacientes incidentes como prevalentes. (AU)


Home hemodialysis (HHD) with low-flow dialysate devices has gained popularity in recent years due to its simple design, portability, and ability to provide greater freedom of movement for our patients. However, there are doubts about the adequacy that this technology offers, since it uses monitors with low-flow bath and lactate. The aim of this study was to demonstrate the clinical benefits of low-flow HHD with the NxStage System One® recently introduced in Spain. We present the results of an observational, retrospective cohort study that included the first patients who started short daily HHD with this device in 12 Spanish centers. We analyzed the evolution of 86 patients at 0, 6 and 12 months, including data related to prescription, and evolution of biochemical parameters related to dialysis dose, anemia, mineral-bone metabolism; evolution of residual renal function, medication usage, and causes of withdrawal during the followup. We were able to demonstrate that this NxStage System One® monitor, in patients with HHD, have provided an adequate dialysis dose, with optimal ultrafiltration rate, with improvement of main biochemical markers of dialysis adequacy. The usage of this technique was associated to a decrease of antihypertensive drugs, phosphate binders and erythropoietin agents, with very good results both patient and technique survival. The simplicity of the technique, together with its good clinical outcomes, should facilitate the growth and utilization of HHD, both in incident and prevalent patients. (AU)


Asunto(s)
Humanos , Hemodiálisis en el Domicilio , Soluciones para Hemodiálisis , Soluciones para Diálisis , Medición de Caudales , Estudios Retrospectivos , España
17.
PLoS One ; 17(6): e0268751, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35666735

RESUMEN

BACKGROUND: Mass spectrometry (MS) analysis using direct infusion of biological fluids is often problematic due to high salts/buffers. Iodinated contrast media (ICM) are frequently used for diagnostic imaging purposes, sometimes inducing acute kidney injury (AKI) in patients with reduced kidney function. Therefore, detection of ICM in spent hemodialysates is important for AKI patients who require urgent continuous hemodiafiltration (CHDF) because it allows noninvasive assessment of the patient's treatment. In this study, we used a novel desalination tube before MS to inject the sample directly and detect ICM. METHODS: Firstly, spent hemodialysates of one patient were injected directly into the electrospray ionization (ESI) source equipped with a quadrupole time-of-flight mass spectrometer (Q-TOF MS) coupled to an online desalination tube for the detection of ICM and other metabolites. Thereafter, spent hemodialysates of two patients were injected directly into the ESI source equipped with a triple quadrupole mass spectrometer (TQ-MS) connected to that online desalination tube to confirm the detection of ICM. RESULTS: We detected iohexol (an ICM) from untreated spent hemodialysates of the patient-administered iohexol for computed tomography using Q-TOF MS. Using MRM profile analysis, we have confirmed the detection of ICM in the untreated spent hemodialysates of the patients administered for coronary angiography before starting CHDF. Using the desalination tube, we observed approximately 178 times higher signal intensity and 8 times improved signal-to-noise ratio for ioversol (an ICM) compared to data obtained without the desalination tube. This system was capable of tracking the changes of ioversol in spent hemodialysates of AKI patients by measuring spent hemodialysates. CONCLUSION: The online desalination tube coupled with MS showed the capability of detecting iohexol and ioversol in spent hemodialysates without additional sample preparation or chromatographic separation. This approach also demonstrated the capacity to monitor the ioversol changes in patients' spent hemodialysates.


Asunto(s)
Lesión Renal Aguda , Compuestos de Yodo , Lesión Renal Aguda/inducido químicamente , Lesión Renal Aguda/diagnóstico , Medios de Contraste/efectos adversos , Soluciones para Hemodiálisis , Humanos , Yohexol , Espectrometría de Masas , Espectrometría de Masa por Ionización de Electrospray
18.
In Vivo ; 36(4): 1769-1776, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35738602

RESUMEN

BACKGROUND/AIM: Supra hemodiafiltration with reinfusion of the endogenous ultrafiltrate (Supra-HFR) is a dialysis technique used to improve uremic toxin removal in the range of the middle molecular weight molecules. Supra-HFR does not require the preparation and online infusion of high-purity dialysis water because it allows the production of an endogenous ultrafiltrate that undergoes detoxification through an adsorbing resin. PATIENTS AND METHODS: We investigated the ability of Supra-HFR to remove fibroblast growth factor 23 (FGF23), interleukin 6 (IL-6), tumor necrosis factor alpha (TNF-alpha), interleukin 8 (IL-8), and transforming growth factor alpha (TGF-alpha) after a single session dialysis in nine patients affected by end stage renal disease (ESRD). The same patients underwent a single session of online hemodiafiltration (OL-HDF) to evaluate possible differences in FGF23 and IL-6 levels. RESULTS: A significant reduction in FGF23 was observed with both Supra-HFR (p=0.001) and OL-HDF. As for TNF-alpha and TGF-alpha, which were measured using Supra-HFR only, their percentage values were significantly lower at the end of dialysis than at the start (p=0.0028 and p=0.03, respectively). This did not change with post-dialysis rebound. Supra-HFR was found to have no effect on IL-6 and IL-8. Interestingly, the removal rate for FGF23 and IL-6 was similar to that observed with OL-HDF. CONCLUSION: Supra-HFR was not superior to OL-HDF, with suboptimal convective volume in the removal of the molecules tested, especially FGF23, which is considered a large middle molecular weight uremic toxin.


Asunto(s)
Hemodiafiltración , Soluciones para Hemodiálisis , Citocinas , Factores de Crecimiento de Fibroblastos , Hemodiafiltración/métodos , Humanos , Interleucina-6 , Interleucina-8 , Factor de Crecimiento Transformador alfa , Factor de Necrosis Tumoral alfa , Tóxinas Urémicas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...