Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.667
Filtrar
1.
Methods Mol Biol ; 2835: 261-267, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39105921

RESUMEN

MXenes are two-dimensional (2D) transition metal-based carbides, nitrides, and carbonitrides that are synthesized from its precursor MAX phase. The selective etching of the "A" from the MAX phase yields multi-functional MXenes that hold promise in a wide range of energy-based applications and biomedical applications. Based on its intended application, MXenes are prepared as multilayered sheets, monolayer flakes, and quantum dots. Conventionally, MXenes are prepared using hydrofluoric (HF) acid etching; however, the use of HF impedes its effective use in biomedical applications. This calls for the use of nontoxic HF-free synthesis protocols to prepare MXenes safe for biological use. Therefore, we have discussed a facile process to synthesize biocompatible, HF-free MXene nanosheets and quantum dots.


Asunto(s)
Nanoestructuras , Puntos Cuánticos , Tantalio , Puntos Cuánticos/química , Tantalio/química , Nanoestructuras/química , Ácido Fluorhídrico/química
2.
ACS Sens ; 9(8): 3921-3927, 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39133300

RESUMEN

Luminescence-based sensing provides a method for the rapid detection of nerve agents. Previous approaches have generally focused on sensing materials containing a nucleophilic group that can react with the electrophilic phosphorus atom found in nerve agents. Herein we report an alternative approach for the detection of phosphonofluoridate-based G-series nerve agents that utilizes the fact they contain hydrogen fluoride. We have developed silylated sensing materials based on an excited-state intramolecular proton transfer (ESIPT) reporter compound, 2-[benzo[d]thiazol-2-yl]phenol. Thin films of differently silylated 2-[benzo[d]thiazol-2-yl]phenol were found to react with the hydrogen fluoride found in di-iso-propyl fluorophosphate (DFP), a simulant of sarin (G-series nerve agent), and turn on the ESIPT emission of the reporter compound. The use of the ESIPT emission reduced the impact of background fluorescence and improved the sensitivity of the detection. The effectiveness of the approach was dependent on the stability of the silyl protecting group used, with the least sterically hindered (trimethylsilyl) found to be too unstable to the ambient environment while the most sterically hindered, e.g., tri-iso-propylsilyl and tert-butyldiphenylsilyl were found to be insufficiently reactive to be useful in a real detection scenario. The sensing material composed of the tert-butyl dimethylsilyl protected 2-[benzo[d]thiazol-2-yl]phenol was found to have the best balance between stability under ambient conditions, and reactivity and selectivity to hydrogen fluoride. In a 3 s exposure, it could detect hydrogen fluoride down to a concentration of around 23 ppm in DFP with 99% purity.


Asunto(s)
Ácido Fluorhídrico , Agentes Nerviosos , Protones , Ácido Fluorhídrico/química , Agentes Nerviosos/análisis , Agentes Nerviosos/química , Éteres/química
3.
Int Orthod ; 22(3): 100897, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38991249

RESUMEN

PURPOSE: The primary objective of this study was to determine which single-shade composite surface yielded clinically acceptable shear bond strength (SBS) to metal orthodontics brackets. The secondary objectives were to identify the best composite surface treatment to enhance SBS and determine which surface treatment produced the least surface damage at debond. METHODS: Forty dental composite samples were selected from four different manufacturers (n=160) and grouped by manufacturer, one standard multi-shade dental system (FilTek™ Supreme Ultra) and three single-shade dental composites systems (OmniChroma®, SimpliShade™ and Venus® Diamond One). Each group of forty samples was randomly divided into four sub-groups (n=10). Each sub-group was identified by the surface treatment used, hydrofluoric acid (HFA), micro-etching (MIC), or phosphoric acid (PA). Shear bond strength testing and adhesive remnant index (ARI) were performed. Statistical analyses included Kruskal-Wallis, Wilcoxon rank-sum, and two-factorial ANOVA. RESULTS: OmniChroma® had statistically significant lower shear bond strength than the other composite materials tested. The control groups had statistically significant lower shear bond strength than Group 1/HFA (P<0.001) and Group 2/MIC (P<0.001). Group 1/HFA had the lowest distribution ARI score overall, while MIC had the highest ARI score distributions. CONCLUSIONS: The results of this in-vitro study found that all tested composite materials achieved clinically acceptable shear bond strengths. The utilization of micro-etching produced higher SBS. Significant Adhesive Remnant Index scores (< 0.001) were only found for OmniChroma® without any surface preparation.


Asunto(s)
Resinas Compuestas , Recubrimiento Dental Adhesivo , Ensayo de Materiales , Soportes Ortodóncicos , Resistencia al Corte , Propiedades de Superficie , Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Grabado Ácido Dental , Ácidos Fosfóricos/química , Análisis del Estrés Dental , Humanos , Ácido Fluorhídrico/química , Grabado Dental/métodos , Cementos de Resina/química
4.
Braz Dent J ; 35: 5669, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39045984

RESUMEN

This study evaluated the influence of hydrofluoric acid (HF) concentration and thermal cycling on the microshear bond strength (µSBS) of a resin luting agent to IPS e.max® CAD and Rosetta® SM. Ceramic specimens (12.0 x 14.0 x 1.5mm) were randomized into 8 groups (n=10) according to HF concentration, commercial brand, and aging. Immediately after polishing, and etching, all specimens were silanized and a layer of adhesive was applied. A PVS mold of 3 mm thickness and 10mm diameter with (four) 1.0mm holes was fabricated, placed on each specimen, and then filled with a resin luting agent. Half of the specimens were subjected to the µSBS test using an Instron at a speed of 1.0 mm/min, following a 24-hour storage in deionized water at 37ºC. The remaining specimens were subjected to thermal cycling (5ºC-55ºC, 30 seconds per bath) and µSBS. The data were evaluated utilizing a three-way ANOVA and Tukey's post-hoc test (α=0.05). Significant differences were found for HF concentration and aging (p<0.0001). No significant difference in µSBS was found for commercial brands (p=0.085). The interaction between brand and HF concentration (p=0.358), brand and aging (p=0.135), and HF concentration and aging (p=0.138) were not statistically significant. The triple interaction among these factors was not statistically significant (p=0.610). In conclusion, the bond strength is affected by the HF concentration. No statistical difference was observed between the two ceramics. Thermal cycling significantly reduced µSBS.


Asunto(s)
Cerámica , Recubrimiento Dental Adhesivo , Ácido Fluorhídrico , Cementos de Resina , Ácido Fluorhídrico/química , Cementos de Resina/química , Cerámica/química , Ensayo de Materiales , Análisis del Estrés Dental
5.
Dent Mater J ; 43(4): 504-516, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-38825449

RESUMEN

The surface treatment of glass-ceramic-based materials, namely, lithium disilicate glass (IPS e.max CAD), feldspar porcelain (VITABLOCS Mark II), and a polymer-infiltrated ceramic network (VITA ENAMIC), using aqueous fluoride solutions and their influence on luting agent bonding were investigated. Six experimental aqueous fluoride solutions were applied to these materials, and their effects were assessed by surface topological analysis. The obtained results were compared using non-parametric statistical analyses. Ammonium hydrogen fluoride (AHF) etchant demonstrated the greatest etching effect. Subsequent experiments focused on evaluating different concentrations of the AHF etchant for the bonding pretreatment of glass-ceramic-based materials with a luting agent (PANAVIA V5). AHF, particularly at concentrations above 5 wt%, effectively roughened the surfaces of the materials and improved the bonding performance. Notably, AHF at a concentration of 30 wt% exhibited a more pronounced effect on both etching and bonding capabilities compared to hydrofluoric acid.


Asunto(s)
Cerámica , Diseño Asistido por Computadora , Porcelana Dental , Fluoruros , Ácido Fluorhídrico , Ensayo de Materiales , Propiedades de Superficie , Fluoruros/química , Cerámica/química , Porcelana Dental/química , Ácido Fluorhídrico/química , Recubrimiento Dental Adhesivo/métodos , Grabado Ácido Dental , Silicatos de Aluminio/química , Compuestos de Potasio/química , Compuestos de Amonio/química
6.
J Burn Care Res ; 45(5): 1321-1324, 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-38842582

RESUMEN

Hydrofluoric acid (HF) is a strongly corrosive, highly toxic, and highly dangerous mineral acid. Burns with over 1% TBSA caused by anhydrous HF can lead to deep tissue damage, hypocalcemia, poisoning, and even death. In recent years, HF has become one of the most common substances causing chemical burns and ranks as the leading cause of death from chemical burns. Herein, we report a rare case with 91% TBSA burns caused by 35% HF. The patient developed complications such as shock, severe hypocalcemia, metabolic acidosis, and respiratory failure. Multidisciplinary team consultation (burns, respiratory medicine, nephrology, infectious disease, and pharmacy) was performed immediately after admission. An individualized diagnosis and treatment plan were developed for the patient. The patient was given intensive care, blood volume monitoring, tracheotomy, fluid resuscitation, continuous blood purification, anti-infective and analgesic treatments, intravenous and percutaneous calcium supplementation, early rehabilitation training, psychological rehabilitation, and other treatments. To prevent the wound from deepening, large-area debridement and skin grafting were performed early after the injury. A large dose of 10% calcium gluconate was injected into the patient in divided doses, and the wound was continuously treated with wet dressings. Multiple surgical debridements, negative pressure wound treatment, biological dressings, and Meek skin grafting were performed. After most of the wounds (approximately 85% TBSA) healed, the patient was discharged from the hospital and continued to undergo dressing changes at a local hospital. The patient was followed up 3 months after discharge. All the wounds healed well, and the patient basically regained functional independence in daily life.


Asunto(s)
Quemaduras Químicas , Ácido Fluorhídrico , Humanos , Quemaduras Químicas/terapia , Quemaduras Químicas/etiología , Masculino , Trasplante de Piel , Desbridamiento , Gluconato de Calcio/uso terapéutico , Adulto
7.
J Contemp Dent Pract ; 25(3): 226-230, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38690694

RESUMEN

AIM: To assess the effectiveness of various surface treatments and adhesives on the bond strength of zirconia-based ceramic to dentin. MATERIALS AND METHODS: Eighty samples of zirconia were subjected to the four-surface treatment protocols (sandblasting, 48% hydrofluoric acid (HF), 48% hydrofluoric acid + 70% nitric acid (HNO3) and no treatment (control) following which the samples from each group were subdivided into two subgroups (n = 10) based on the resin cement employed for cementation (RelyX U200 and G-Cem Linkforce). The bonded specimens were subjected to shear stress to measure the bond strength using Universal testing machine. To test the difference in bond strength among the eight study groups, the Kruskal-Wallis ANOVA test was applied and for comparison between cements in each group, Mann-Whitney U test was applied. RESULTS: The highest bond strength values were observed for 48% HF group cemented with G-Cem Linkforce resin cement (16.220 ± 1.574) and lowest for control group-RelyX (4.954 ± 0.972). G-Cem cement showed higher bond strength than RelyX for all surface treatments except 48% HF + 70% nitric acid. CONCLUSION: It can be inferred that 48% HF can etch zirconia and generate a porous structure that proves to be beneficial for bonding. CLINICAL SIGNIFICANCE: The increasing demand for esthetics has led to the replacement of metal-ceramic materials with zirconia-based ceramics. However, the chemical inertness of zirconia to various conventional surface treating agents has continuously challenged researchers to discover a new surface treatment protocol that could enhance the bond strength of zirconia. How to cite this article: Yenamandra MS, Joseph A, Singh P, et al. Effect of Various Surface Treatments of Zirconia on its Adhesive Properties to Dentin: An In Vitro Study. J Contemp Dent Pract 2024;25(3):226-230.


Asunto(s)
Recubrimiento Dental Adhesivo , Dentina , Ensayo de Materiales , Cementos de Resina , Propiedades de Superficie , Circonio , Cementos de Resina/química , Recubrimiento Dental Adhesivo/métodos , Técnicas In Vitro , Humanos , Análisis del Estrés Dental , Resistencia al Corte , Ácido Fluorhídrico/química , Ácido Nítrico/química , Cerámica/química
9.
Braz Dent J ; 35: e245641, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38537017

RESUMEN

This study verified the effect of the combination of preheated hydrofluoric acid/silane/electric current in the adhesion of the resin cement to ceramic. IPS E.max Press ceramic discs embedded in PVC rigid tubes were divided into four groups associating preheated hydrofluoric acid and silane applied with electrical current (n=10): Ha+S (Heated acid + silane); Ha+S+Ec (Heated acid + silane + electrical current); A+S (Acid + silane) and A+S+Ec (Acid + silano + electrical current). Resin cement/ceramic samples were stored in water at 37°C for 24h. After storage, they were submitted to the microshear test, fracture analysis, and contact angle at 24h or after thermocycling (10,000 cycles/5-55ºC). Bond strength data were evaluated by two-way ANOVA. For comparison between evaluation times (24h or thermocycling) was applied unpaired t-test. A significance post-hoc test of p=0.05 was assumed for analyses and graphs (GraphPad Prism 9.0 software). At 24h, the microshear strength showed similar values between Ha+S, Ha+S+Ec, and A+S+Ec groups, while A+S showed the lowest value with a statistical difference. After thermocycling, Ha+S and Ha+S+Ec were similar, as well as A+S and A+S+Ec. There was a significant difference in all groups comparing 24h (highest value) with after thermocycling (lowest value). Adhesive fracture was predominant in all groups and evaluation times. Ha+S and A+S groups showed higher contact angle values compared to the Ha+S+Ec and A+S+Ec with lower values. In conclusion, the association of preheated hydrofluoric acid/silane applied or not with electric current promoted different microshear strength values, fracture types, and contact angles in the resin cement/ceramic bond.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Cementos de Resina/química , Silanos/química , Ácido Fluorhídrico/química , Propiedades de Superficie , Grabado Ácido Dental , Cerámica/química , Porcelana Dental/química , Ensayo de Materiales
10.
J Adhes Dent ; 26(1): 11-18, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38240152

RESUMEN

PURPOSE: To evaluate the effect of different lithium-disilicate (LiSi) glass-ceramic surface decontamination procedures on the shear bond strength (SBS) to resin cement. MATERIALS AND METHODS: Seventy CAD/CAM LiSi ceramic specimens (IPS e.max CAD, Ivoclar) were cut and sintered. Fifty specimens were treated with 5% hydrofluoric acid (HF) for 20 s, while 20 were left untreated. All 70 specimens were then contaminated with human saliva and try-in silicone paste. The following surface cleaning methods were investigated (n = 10): C: water rinsing (control); PA: 37% H3PO4 etching for 20 s; E: 70% ethanol applied for 20 s; CP: cleaning paste (Ivoclean, Ivoclar) brushed for 20 s; HFSEP: self-etching ceramic primer (Monobond Etch&Prime, Ivoclar) rubbed for 20 s; HF: 5% HF applied for 20 s or no HF etching prior to contamination; SEP: self-etching ceramic primer rubbed for 20 s and no HF etching prior to contamination. Composite cylinders were created and luted with an adhesive resin cement to the decontaminated surfaces. After storage for 24 h at 37°C, the SBS test was conducted. Two fractured specimens per group were observed under SEM to perform fractographic analysis. The data were statistically analyzed with p set at <0.05. RESULTS: The type of surface cleaning approach influenced bond strength (p < 0.001). HFSEP, SEP, and HF attained higher SBS (p < 0.001) compared to other groups. None of the approaches were able to completely remove contaminants from the ceramic surfaces. SEM images showed residual traces of contaminants on CP-treated surfaces. CONCLUSIONS: The self-etching ceramic primer enhanced bond strength to contaminated LiSi ceramic surfaces, irrespective of previous treatment with hydrofluoric acid.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Humanos , Litio , Ácido Fluorhídrico , Propiedades de Superficie , Ensayo de Materiales , Porcelana Dental , Cerámica , 2-Propanol , Silanos
11.
J Esthet Restor Dent ; 36(1): 47-55, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37772362

RESUMEN

OBJECTIVE: To evaluate the effect of different hydrofluoric acid concentrations and etching times on the surface, chemical composition and microstructure of lithium disilicate. MATERIAL AND METHODS: Ninety specimens of pressed lithium disilicate (LDS) were obtained (IPS e.max Press, Rosetta SP and LiSi Press). The specimens of each material were divided in two groups according to the hydrofluoric acid concentration: 5% and 10% (n = 15/group), and subdivided according to the etching time: 20, 40 and 60 s (n = 5/group). Crystalline evaluations and chemical composition were performed through x-ray diffraction (XRD) and energy-dispersive x-ray spectroscopy (EDS), respectively. Microstructural analyses were performed by scanning electron microscope (SEM), surface roughness (Ra), and material thickness removal evaluation. Thickness removal and Ra data were analyzed by ANOVA and Tukey test (p < 0.05). RESULTS: XRD demonstrated characteristic peaks of lithium disilicate crystals, lithium phosphate and of a vitreous phase for all materials. EDS identified different compositions and SEM confirmed different surface responses to acid etching protocols. Material and etching time influenced Ra and material thickness removal (p < 0.05). CONCLUSION: Hydrofluoric acid concentration and etching time affect the surface characteristics of LDS differently. LiSi Press presented higher resistance to hydrofluoric acid etching compared to e.max Press and Rosetta SP. CLINICAL SIGNIFICANCE: Applying the appropriate etching protocol is pivotal to avoid excessive material removal and to prevent jeopardize the mechanical and optical properties of the material.


Asunto(s)
Recubrimiento Dental Adhesivo , Ácido Fluorhídrico , Ácido Fluorhídrico/química , Ensayo de Materiales , Porcelana Dental/química , Cerámica/química , Propiedades de Superficie , Recubrimiento Dental Adhesivo/métodos , Cementos de Resina/química
12.
Artículo en Inglés | MEDLINE | ID: mdl-37819852

RESUMEN

Ultrathin ceramic veneers are a viable therapeutic option to manage esthetic challenges in the anterior zone. Proper conditioning of the intaglio surface of porcelain veneers is essential to achieve an adequate bonding. In clinical practice, this is typically done with chemical etching using an acid-containing agent, such as hydrofluoric acid. While it is well established that the etching effect is dependent on etching time and the acid concentration, little is known about the impact of etching time and the veneer fabrication method. The purpose of this pilot study was to evaluate, using scanning electron microscopy (SEM), the effect that different etching-time protocols have on the intaglio surface characteristics of ultrathin ceramic veneers fabricated with either the platinum foil technique or the refractory die technique. Several replicas of an ultrathin feldspathic ceramic veneer for a maxillary central incisor were fabricated. Individual specimens were processed according to different intaglio surface-etching protocols: no etching, etching for 90 seconds, etching for 120 seconds, and etching for 150 seconds (9.6% hydrofluoric acid used for all etching groups). It was observed that the 120-second etching protocol resulted in a favorable microroughness surface pattern in the platinum foil group. This pattern was comparable to that obtained by etching for 90 seconds with hydrofluoric acid the intaglio surface of veneers fabricated with the refractory die technique. Increasing the etching time to 150 seconds did not result in a more favorable roughness pattern.


Asunto(s)
Recubrimiento Dental Adhesivo , Porcelana Dental , Humanos , Ácido Fluorhídrico , Microscopía Electrónica de Rastreo , Platino (Metal) , Proyectos Piloto , Grabado Ácido Dental/métodos , Propiedades de Superficie , Cerámica , Ensayo de Materiales , Cementos de Resina
13.
Burns ; 50(2): 488-494, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38087660

RESUMEN

Hydrofluoric acid (HF) is a ubiquitous industrial chemical that is particularly hazardous because of the potential for systemic effects and the induction of severe cutaneous necrosis after contact with the skin. Minimizing skin injury requires decontaminating the affected area promptly with an emergency rinsing solution. Few experimental studies have objectively characterized rinsing solutions such as Diphoterine (DP). Here we develop an ex vivo pigskin model to study and compare the efficacy of rinsing solutions as initial decontaminating agents to stop the progression of skin lesions after HF splashing. The pigskin model shows an immediate local response to HF at varying concentrations and exposure times. We then exposed the pigskin biopsies to 3.75% HF for 1 min and rinsed them with different solutions, including water, 0.9% NaCl solution (saline), 10% calcium gluconate (CaG), Hexafluorine (HXF), and DP. We found DP to be a more effective agent for decontaminating HF lesions than water, saline, and CaG. DP had a similar efficacy as HXF, an emergency rinsing solution used specifically for decontaminating HF-exposed skin. This study shows that skin exposed to HF must be treated quickly from the first minute of exposure.


Asunto(s)
Quemaduras Químicas , Compuestos de Flúor , Humanos , Ácido Fluorhídrico , Quemaduras Químicas/terapia , Gluconato de Calcio , Solución Salina , Agua , Compuestos Orgánicos
14.
Dent Mater J ; 43(1): 52-57, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38044145

RESUMEN

This study investigated the degree of phase transformation, surface roughness, and bond strength of zirconia immersed for various times in a 40% hydrofluoric acid (HF) solution. Non-etched sintered zirconia specimens were used as the control, while experimental groups were etched with a 40% HF solution for 5, 10, 20, 40, 80, 160 and 320 min. In each of the control and experimental groups, five specimens for X-ray diffraction analysis, four for surface morphology and surface roughness analysis, and ten for bonding strength measurement were used. As a result, the surface roughness of zirconia increased as the application time increased during the 40% HF etching, but the bond strength between zirconia and resin cement did not increase proportionally. The phase transformation from tetragonal to monoclinic also gradually increased with application time.


Asunto(s)
Recubrimiento Dental Adhesivo , Ácido Fluorhídrico , Ácido Fluorhídrico/química , Inmersión , Circonio/química , Propiedades de Superficie , Cementos de Resina/química , Ensayo de Materiales , Cerámica/química
15.
Odontology ; 112(1): 74-82, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37036616

RESUMEN

Because the use of hydrofluoric acid (HF) poses health risks if handled improperly, many clinicians prefer to have the ceramic restorations pre-etched in dental laboratories. However, during the try-in procedure, the pre-etched glass-ceramic restorations may be contaminated with saliva resulting in reduced bond strength. This in-vitro study aimed to investigate the effect of different surface treatments on the bond strength of lithium disilicate (LD) glass-ceramic restorations (IPS e.max Press, Ivoclar Vivadent) to two resin cements. One-hundred eighty blocks (4X4X3mm) of LD glass-ceramic were divided into twelve groups (n = 15), of which six received Variolink Esthetic DC (VE) cement and six received RelyX Ultimate (RU) cement, following the surface treatments: G1) Control: Hydrofluoric Acid + Silane (HF + Sil); G2) Hydrofluoric Acid + Saliva + Silane (HF + S + Sil); G3) Hydrofluoric Acid + Saliva + Ivoclean + Silane (HF + S + IC + Sil); G4) Hydrofluoric Acid + Saliva + Phosphoric Acid + Silane (HF + S + P + Sil); G5) Hydrofluoric Acid + Saliva + Monobond Etch & Prime (HF + S + EP); G6) Monobond Etch & Prime (EP). Following treatment, a resin-cement cylinder (2.3 mm diameter) was built on the glass-ceramic surface, photocured (20 s), stored in distilled water (37 °C, 24 h) and submitted to the shear bond strength test. Bond strength data (MPa) were subjected to two-way ANOVA and Tukey (α = 0.01). Cement type and surface treatment had a significant effect on the bond strength (p < 0.001) (Table 4). Single-step Monobond Etch & Prime (EP) significantly improved the bond strength of resin-cements to glass-ceramic with and without saliva contamination.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Cementos de Resina/química , Ácido Fluorhídrico , Silanos , Propiedades de Superficie , Porcelana Dental , Cerámica , Cementos Dentales , Protocolos Clínicos , Ensayo de Materiales
16.
J Mech Behav Biomed Mater ; 150: 106312, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38134583

RESUMEN

This study aimed to compare the fatigue performance of a lithium disilicate ceramic cemented on different substrates (human dentin and glass fiber-reinforced epoxy resin - GFRER), treated with different types of conditioning (CTR - without surface conditioning; HF5 - 5% hydrofluoric acid; HF10 - 10% hydrofluoric acid; H3PO4 - phosphoric acid 37%; SAND - sandblasting with aluminum oxide). The occlusal surface of human molars (DENT group) (n = 15) was ground for dentin exposure and the root portion was cut, then the dentin slice (2.0 mm thick) was conditioned with 37% phosphoric acid and a dual-curing dental adhesive was applied. The GFRER in a round-rod format was cut into discs (Ø = 10 mm, 2.0 mm thick). Lithium disilicate glass ceramic blocks (IPS e.max CAD, Ivoclar, Schaan, Liechtenstein) were shaped into a cylinder format and cut, resulting in 90 discs (Ø = 10 mm, 1.5 mm thick). The substrate materials of each group were etched according to the groups and the ceramic was etched with 5% hydrofluoric acid for 30 s. A silane coupling agent was applied over the cementation surface in ceramic and GFRER surfaces and a dual cement was used for cementation (ceramic/GFRER or dentin). The disc/disc sets were submitted to thermocycling (25,000 cycles + storage for 6 months), and then tested in step-wise accelerated cyclic fatigue test. The failure pattern and topography were analyzed and the roughness and contact angle were measured before and after surface treatment. The DENT group presented the lowest load to failure values and number of cycles to failure in fatigue (637.33 N; 118.333), showing no statistical similarity with any of the other tested groups (p < 0.05). The topographic analysis showed that all proposed surface treatments modified the substrate surface when compared to the CTR group. All of the fractographical inspections demonstrated failure by radial crack. Considering the roughness analysis, the post-etched DENT group showed similar roughness to all groups of GFRER materials with their surface treated, except for SAND, which showed greater roughness and statistically different from the other groups. The DENT group (49.5) showed statistically different post-conditioning contact angle values from the HF10 group (96.5) and similar to the other groups. The glass fiber-reinforced epoxy resin was not able to simulate the results presented by the human dentin substrate when cemented to lithium disilicate regarding fatigue failure load and number of cycles for failure, regardless of the surface treatment. Lithium disilicate cemented on dentin analogue overestimates the load values for fatigue failure.


Asunto(s)
Cerámica , Ácido Fluorhídrico , Humanos , Propiedades de Superficie , Ensayo de Materiales , Análisis del Estrés Dental , Dentina
17.
J Mech Behav Biomed Mater ; 150: 106338, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38159495

RESUMEN

The aim of this study was to mechanically characterize through flexural fatigue test two CAD-CAM glass-ceramics according to distinct surface etching protocols. To do so, feldspathic (FELD) and lithium disilicate (LD) glass ceramics were subjected to different surface treatments: (1) control - no treatment (Ctrl); (2) conventional protocol etching with 5% hydrofluoric acid followed by silane coupling agent application (HF + SIL; Monobond N, Ivoclar); or (3) using a self-etching ceramic primer (E&P; Monobond Etch & Prime, Ivoclar). Ceramic discs (N = 120; Ø = 12 mm; thickness = 1.2 mm) were produced from CAD-CAM blocks, with 60 being from FELD (VITABLOCS Mark II, Vita Zahnfabrik) and 60 from LD (IPS e.max CAD, Ivoclar). Next, 20 disks of each ceramic were allocated into three groups: Ctrl, HF + SIL, or E&P. Surface roughness data were collected on all samples before and after surface treatments (except for Ctrl). Cyclic fatigue (n = 15) biaxial flexural strength tests were performed by the piston-on-three-balls geometry (ISO 6872) considering the test parameters established from a monotonic test (n = 5). The monotonic test was carried out at a 1 mm/min loading rate and 500 kgf loading cell until fracture to obtain the failure data. The cyclic fatigue test was executed underwater at a frequency up to 20 Hz, with the first stress being 25% of the monotonic test for 5000 cycles, followed by increments of 5% of the monotonic test at each step of 10,000 cycles until failure (fracture). Complementary fractography, topography and Atomic Force Microscopy (AFM) analyses were performed. Characteristic Fatigue Strength (CFS) and Weibull modulus were analyzed by Weibull analysis using the fatigue test data. Roughness and complementary analysis data were analyzed by one-way ANOVA. The statistical results exhibited similar CFS among Ctrl, HF + SIL and E&P for both glass-ceramics. The survival analysis corroborates the findings, however the Weibull modulus pointed out superior structural reliability of FELD treated with the E&P group compared to HF + SIL. According to the complementary analyses, HF + SIL exhibited a higher surface area than E&P and Ctrl for FELD (p = 0.001). Roughness showed statistically significant differences among conditions for FELD (E&P < Ctrl = HF + SIL; p < 0.05) and no difference for LD (p > 0.05). Therefore, the CFS were not influenced by any condition evaluated for FELD and LD glass-ceramics; however, superior structural reliability (higher Weibull modulus) for the feldspathic ceramic treated with the E&P was observed.


Asunto(s)
Recubrimiento Dental Adhesivo , Silanos , Propiedades de Superficie , Silanos/química , Ácido Fluorhídrico , Reproducibilidad de los Resultados , Ensayo de Materiales , Grabado Ácido Dental , Cerámica/química , Porcelana Dental , Análisis del Estrés Dental , Cementos de Resina
18.
J Adhes Dent ; 25(1): 231-240, 2023 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-37975312

RESUMEN

PURPOSE: To conduct a systematic review and meta-analysis of in-vitro bond strength to glass-ceramics using hydrofluoric acid (HF) at lower (<5%) and higher (>5%) concentrations ([HF]) to treat ceramic surfaces. METHODS: Systematic searches were carried out in PubMed, Scopus, LILACS, and Web of Science for articles published through July 2021, and a meta-analysis was performed to estimate the combined effect by comparing the differences between the standardized means of the bond strengths of the evaluated materials. RESULTS: In total, 943 articles were found, of which 17 studies were selected for qualitative analysis and 12 for quantitative analysis. The bond strength to glass-ceramics using 4% to 5% HF did not differ from that using 7% to 10% HF for the following HF etching times and glass-ceramic materials: 20 s for lithium-disilicate (Z = 0.65, p = 0.51), 60 s for feldspathic (Z = 0.53, p = 0.60), and 60 s for leucite (Z = 0.72, p = 0.35). CONCLUSION: The lower concentration HF (<5%) etchant is a reliable surface treatment for adhesive bonding to glass-ceramics with satisfactory bond strength in short-term evaluations.


Asunto(s)
Recubrimiento Dental Adhesivo , Ácido Fluorhídrico , Ácido Fluorhídrico/química , Grabado Ácido Dental , Cementos de Resina/química , Propiedades de Superficie , Ensayo de Materiales , Cerámica/química , Porcelana Dental/química
19.
PLoS One ; 18(10): e0292168, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37816018

RESUMEN

To overcome the corrosion of hydrofluoric acid on the ICP OES injection system in the acid dissolution system, this paper makes some improvements based on the traditional open digestion. The improved method does not require the complete removal of hydrofluoric acid. After appropriate digestion of the sample with a mixed acid, the solution can be transferred to a colorimetric tube containing ammonium hydroxide solution to give the final volume for analysis. In this paper, two-point standard curves are plotted using soil standards and process blanks, which is not only convenient but also overcomes the interference of the matrix effect. Through continuous experiments, the preferred ratio of mixed acid is 3 mL nitric acid + 5 mL hydrofluoric acid, and the concentration of ammonia solution is 0.5%. The spectral lines of the measured elements V (292.4), Cr (283.5), Co (228.6), Ni (231.6), Cu (324.7), Zn (213.8) and Pb (220.3) were determined. The method quantification limits of the seven measured elements V, Cr, Co, Ni, Cu, Zn and Pb were 0.909, 4.32, 0.269, 0.261, 0.968, 3.69 and 2.64 µg g-1, respectively, and the precision was 3.5%, 5.2%, 4.8%, 2.4%, 6.1% and 4.5%, respectively. After processing six national standard materials according to the experimental method, the measured values of each measured element were basically in agreement with the certified values, indicating that this method is fully feasible for the measurement of V, Cr, Co, Ni, Cu, Zn and Pb in soil. This method greatly improves the efficiency of pretreatment and is particularly suitable for analysing large batches of samples.


Asunto(s)
Amoníaco , Oligoelementos , Amoníaco/análisis , Suelo , Ácido Fluorhídrico , Plomo/análisis , Solubilidad , Oligoelementos/análisis
20.
J Mech Behav Biomed Mater ; 148: 106169, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37837872

RESUMEN

When partial and/or non-retentive preparation, such as those for occlusal veneers, is indicated, a proper and stable adhesion is essential. Therefore, the aim of this in vitro study was to evaluate the effect of loss of adhesion in different regions of the bonding interface on the fatigue behavior of simplified lithium disilicate restorations. For this, lithium disilicate (IPS e.max CAD) discs (1 mm thick and Ø = 10 mm) were fabricated, polished with #400-, #600-, #1200-grit silicon carbide (SiC) papers, and crystallized. As substrate, fiber-reinforced resin epoxy discs (2.5 mm thick and Ø = 10 mm) were fabricated and polished with #600-grit SiC paper. The ceramic bonding surface was treated with 5% hydrofluoric acid and a silane-containing primer (Monobond N), while the substrate was etched with 10% hydrofluoric acid followed by the application of the bonding system primers (Primer A + B). A lacquer (nail polish) was used to simulate the loss of adhesion in specific areas according to the study design to compose the testing groups: bonded (control; did not received nail polish application); - non-bonded (loss of adhesion in the whole specimen area); - margin (loss of adhesion in the ceramic margin); - center (loss of adhesion in the ceramic central area). The adhesive area of partially bonded groups was 50% of the adhesive surface. Then, the discs (n = 12) were bonded to the respective substrate using a resin cement (Multilink N), light-cured, water-stored for 90 days, and subjected to thermocycling (25,000 cycles, 5° to 55 °C) before testing. A cyclic fatigue test was run (20 Hz, initial load of 200 N for 5000 cycles, 50 N step size for 10,000 cycles each until specimen failure), and the fatigue failure load and number of cycles for failure were recorded. As complementary analysis, finite element analysis (FEA) and scanning electron microscopy analysis were performed. Kaplan-Meier log-rank (Mantel-Cox) was conducted for survival analysis. The results showed that as the loss of adhesion reaches the central area, the worse is the fatigue behavior and the higher is the stress peak concentration in the ceramic bonding surface. The bonded specimens presented better fatigue behavior and stress distribution compared to the others. In conclusion in a non-retentive preparation situation, proper adhesion is a must for the restoration fatigue behavior even after aging; while the loss of adhesion reaches central areas the mechanical functioning is compromised.


Asunto(s)
Cerámica , Cementos de Resina , Cerámica/química , Cementos de Resina/química , Ácido Fluorhídrico/química , Propiedades de Superficie , Ensayo de Materiales , Análisis del Estrés Dental , Porcelana Dental
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA