Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.297
Filtrar
4.
J Refract Surg ; 40(7): e480-e489, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39007817

RESUMEN

PURPOSE: To evaluate the effectiveness, safety, and stability of a modified PRESBYOND Laser Blended Vision protocol (Carl Zeiss Meditec AG) for correcting hyperopic astigmatism and presbyopia, using Custom Refractive Software Master (CRSM) targeting over a 6-month period. METHODS: A total of 636 eyes of 318 patients with a mean age of 51.05 ± 4.71 years (range: 40 to 60 years) met the inclusion and exclusion criteria. All patients completed a 6-month follow-up. CRSM software was used to generate ablation profiles for the MEL90 excimer laser (Carl Zeiss Meditec AG). The target refraction was emmetropic for the dominant eyes and between -0.75 and -1.12 diopters (D) for the near eyes. RESULTS: Visual and refractive results were studied separately by the dominant and non-dominant eyes. The mean attempt to correct for spherical equivalent refraction was +2.17 ± 1.16 D (range: -1.00 to +5.37 D). The mean attempted cylinder was -0.60 ± 0.75 D (range: -4.00 to 0.00 D). All eyes monocularly achieved uncorrected distance visual acuity (UDVA) of 20/25 or better after refractive treatment and 88% achieved 20/20. Binocularly all eyes achieved UDVA of 20/25 or better and 96.54% achieved 20/20. Ninety-eight percent of the patients maintained their corrected distance visual acuity before surgery and UDVA 6 months after surgery. CONCLUSIONS: This hyperopic micro-anisometropia protocol with PRESBYOND Laser Blended Vision was an effective, safe, and well-tolerated refractive treatment. It was an effective procedure with excellent results for UDVA and uncorrected near visual acuity and demonstrates that binocular summation exists. [ J Refract Surg. 2024;40(7):e480-e489.].


Asunto(s)
Astigmatismo , Hiperopía , Queratomileusis por Láser In Situ , Láseres de Excímeros , Presbiopía , Refracción Ocular , Programas Informáticos , Agudeza Visual , Humanos , Presbiopía/cirugía , Presbiopía/fisiopatología , Queratomileusis por Láser In Situ/métodos , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Láseres de Excímeros/uso terapéutico , Masculino , Hiperopía/fisiopatología , Hiperopía/cirugía , Persona de Mediana Edad , Femenino , Adulto , Astigmatismo/fisiopatología , Astigmatismo/cirugía , Resultado del Tratamiento , Anisometropía/fisiopatología , Anisometropía/cirugía , Topografía de la Córnea , Estudios de Seguimiento , Estudios Prospectivos , Córnea/fisiopatología , Córnea/cirugía
5.
BMC Ophthalmol ; 24(1): 271, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38918731

RESUMEN

BACKGROUND: The success of the strabismus surgery can hinge on several factors. One of these factors is refractive condition like hyperopia or myopia. Our study seeks to evaluate the surgical outcomes in patients with esotropia and myopia. METHODS: This case-control study encompassed all surgical cases of esotropia at Torfe and Negah Hospital between 2016 and 2021, which satisfied our specified inclusion criteria. The initial variables from electronic medical records were collected, including demographic, clinical, and surgery-related factors. At the final follow-up appointment, the level of eye deviation, both at distance and near, was recorded. We considered the operation a "success" for patients with a post-surgery distance eye deviation of 10(Pd) or less. Patients with greater deviation were classified as surgery failure. Statistical analyses were executed using SPSS software (version 16.0), and a P-value less than 0.05 was considered significant. RESULTS: Of the 194 patients evaluated, 112 were incorporated into the study. Surgical failure was observed in 14.29% of myopic patients, 29.79% of hyperopic patients, and 31.82% of emmetropic patients. The myopia group displayed a 0.19 odd ratio for surgical failure compared to the combined hyperopia and emmetropia groups, not statistically significant (OR: 0.19, CI 95%: 0.03-1.02). Additionally, patients diagnosed with Lateral Rectus Under-action were found to be 6.85 times more likely to experience surgery failure(OR: 6.85, CI 95%: 1.52-30.94). An elevated risk of surgical failure was also identified in patients who underwent Inferior Oblique Weakening procedure, indicated by a 3.77-fold increase in the odds ratio for failure(OR: 3.77, CI 95%: 1.08-13.17). CONCLUSION: In our study, despite numerical disparities, there was no statistical difference among the success rates of all esotropia patients with different refractive errors. The patients with LRUA or IOOA showed lower success rates. Myopic patients had higher post-op overcorrection with lower reoperation rates compared to hyperopic or emmetropic patients.


Asunto(s)
Esotropía , Músculos Oculomotores , Procedimientos Quirúrgicos Oftalmológicos , Visión Binocular , Agudeza Visual , Humanos , Esotropía/cirugía , Esotropía/fisiopatología , Masculino , Femenino , Procedimientos Quirúrgicos Oftalmológicos/métodos , Estudios de Casos y Controles , Músculos Oculomotores/cirugía , Músculos Oculomotores/fisiopatología , Niño , Agudeza Visual/fisiología , Preescolar , Visión Binocular/fisiología , Estudios Retrospectivos , Adulto , Refracción Ocular/fisiología , Miopía/cirugía , Miopía/fisiopatología , Miopía/complicaciones , Adolescente , Hiperopía/cirugía , Hiperopía/fisiopatología , Hiperopía/complicaciones , Resultado del Tratamiento , Persona de Mediana Edad , Adulto Joven , Estudios de Seguimiento
6.
J Cataract Refract Surg ; 50(9): 919-925, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38758195

RESUMEN

PURPOSE: To evaluate visual outcomes of high hyperopic laser in situ keratomileusis (LASIK), using corneal aspherization to control the induced spherical aberration. SETTING: Fondation Ophtalmologique Adolphe de Rothschild, Paris, France. DESIGN: Prospective interventional case series. METHODS: Prospective interventional study of consecutive high hyperopes (≥+3 diopters [D] of spherical equivalent [SE]) undergoing LASIK with the WaveLight FS200 femtosecond and EX500 excimer laser platform. An aspheric ablation profile (planned change in corneal asphericity ΔQ = +0.2) was delivered using the Custom-Q nomogram on an optical zone of ≥6.5 mm centered near the corneal vertex. Uncorrected corrected distance visual acuity (UDVA) and corrected distance visual acuity, as well as changes in SE, corneal asphericity (ΔQ), and higher-order aberrations, were analyzed preoperatively and on day 1, 1, 3, 6, and 12 months. RESULTS: 117 eyes of 63 patients (mean age of 30.1 ± 5.6 years) were included. Preoperatively and at 12 months postoperatively, the mean SE was 5.1 ± 1.1 D and 0.00 ± 0.7 D, respectively. 88% of eyes achieved 0 logMAR or better UDVA at 12 months. 1 month postoperatively, there was a statistically significant induction of positive spherical aberration decreasing progressively and significantly until the last visit (preop SA4 = 0.09 ± 0.11 µm, day 1 SA4 = 0.30 ± 0.32 µm, 12 months SA4 = 0.08 ± 0.21 µm, P = .056). 2 eyes needed enhancement at 12 months. CONCLUSIONS: LASIK for high levels of hyperopia showed good outcomes mainly due to aspheric-customized ablation profile with a change of ΔQ = +0.2 in corneal asphericity.


Asunto(s)
Topografía de la Córnea , Aberración de Frente de Onda Corneal , Hiperopía , Queratomileusis por Láser In Situ , Láseres de Excímeros , Refracción Ocular , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Hiperopía/cirugía , Hiperopía/fisiopatología , Estudios Prospectivos , Agudeza Visual/fisiología , Adulto , Láseres de Excímeros/uso terapéutico , Refracción Ocular/fisiología , Masculino , Femenino , Aberración de Frente de Onda Corneal/fisiopatología , Córnea/cirugía , Córnea/fisiopatología , Adulto Joven , Enfermedades Hereditarias del Ojo
7.
J Refract Surg ; 40(5): e321-e327, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717082

RESUMEN

PURPOSE: To evaluate the characteristic of corrective epithelial thickness after femtosecond laser-assisted lenticule intrastromal keratoplasty (LIKE) to correct moderate-to-high hyperopia. METHODS: The prospective case series study of the LIKE procedure was performed to correct moderate-to-high hyperopia. The epithelial thickness map was generated by anterior segment optical coherence tomography (AS-OCT) in the corneal central 9-mm zone. Keratometry and corneal higher order aberrations were analyzed by Pentacam (Oculus Optikgeräte GmbH) preoperatively and postoperatively. RESULTS: In the 26 eyes of 13 participants who underwent the LIKE procedure for moderate-to-high hyperopia, the attempted spherical equivalence (SEQ) was +6.50 ± 1.09 diopters (D). Compared to the preoperative epithelial thickness maps, the postoperative epithelial thickness had become significantly thinner in the central 5-mm zone; the difference was 6 to 7 µm. The paracentral epithelium performed nonuniform remodeling; the thinnest epithelial thickness was located in the inferotemporal section, which has the greatest difference from the superonasal; the difference between these two was approximately 3 µm. Through correlation analysis, it was found that the sections with thinner epithelium were significantly related to corneal curvature and corneal vertical coma. CONCLUSIONS: The LIKE procedure can be used to correct moderate-to-high hyperopia. This study further indicated the epithelial remodeling characteristic after the LIKE procedure: the central and paracentral corneal epithelial thickness becomes thinner, and the epithelial thickness distributes non-uniformly, which may be the important factor of the postoperative curvature asymmetric distribution and induction of corneal vertical coma. [J Refract Surg. 2024;40(5):e321-e327.].


Asunto(s)
Sustancia Propia , Topografía de la Córnea , Epitelio Corneal , Hiperopía , Refracción Ocular , Tomografía de Coherencia Óptica , Agudeza Visual , Humanos , Hiperopía/cirugía , Hiperopía/fisiopatología , Estudios Prospectivos , Sustancia Propia/cirugía , Sustancia Propia/patología , Masculino , Femenino , Adulto , Agudeza Visual/fisiología , Epitelio Corneal/cirugía , Epitelio Corneal/patología , Refracción Ocular/fisiología , Persona de Mediana Edad , Láseres de Excímeros/uso terapéutico , Adulto Joven , Aberración de Frente de Onda Corneal/fisiopatología , Cirugía Laser de Córnea/métodos , Enfermedades Hereditarias del Ojo
8.
J Refract Surg ; 40(5): e313-e320, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717079

RESUMEN

PURPOSE: To assess the clinical outcomes and safety profiles of patients who underwent immediate sequential bilateral phakic lens surgery. METHODS: This retrospective multicenter study included 254 consecutive patients (508 eyes) who underwent bilateral same-day Implantable Collamer Lens (ICL) (STAAR Surgical) surgery. The authors focused on 1-year postoperative clinical outcomes and adverse events. RESULTS: In the initial cohort, 176 patients (352 eyes) met inclusion criteria. Of these, 335 eyes underwent myopic ICL placement, and 17 eyes received a hyperopic ICL. Notably, 87% of eyes achieved ±0.50 diopters (D) and 95% achieved ±1.00 D of the intended refraction. One year postoperatively, 78% of eyes demonstrated optimal vaulting (250 to 750 µm), with a significant 19% reduction in vaulting observed over the 12 months (P < .001). Only minor adverse events, including early cataract formation (1 case), secondary toric ICL rotation (3 cases), and ICL exchange due to inappropriate vaulting (6 cases), were noted. CONCLUSIONS: The findings corroborate the safety and efficacy of immediate sequential bilateral phakic lens surgery and indicate its potential as a treatment option. The low incidence of minor adverse events further reinforces its favorable safety profile. [J Refract Surg. 2024;40(5):e313-e320.].


Asunto(s)
Hiperopía , Implantación de Lentes Intraoculares , Miopía , Lentes Intraoculares Fáquicas , Refracción Ocular , Agudeza Visual , Humanos , Estudios Retrospectivos , Masculino , Agudeza Visual/fisiología , Femenino , Adulto , Miopía/cirugía , Miopía/fisiopatología , Refracción Ocular/fisiología , Hiperopía/cirugía , Hiperopía/fisiopatología , Adulto Joven , Resultado del Tratamiento , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios de Seguimiento , Adolescente
9.
J Cataract Refract Surg ; 50(6): 550-557, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38305328

RESUMEN

PURPOSE: To compare corrected distance visual acuity (CDVA) outcomes of hyperopic laser in situ keratomileusis (LASIK) with a postoperative corneal steepness above vs below 49 diopters (D). SETTING: Care-Vision Laser Centers, Tel-Aviv, Israel. DESIGN: Retrospective study. METHODS: This study included consecutive patients who underwent hyperopic LASIK between January 2013 and December 2019. Hyperopic patients were divided into 2 groups based on postoperative corneal steepness with steep corneas defined >49.0 D and the control group ≤49.0 D. Adjustments were performed to account for differences in baseline and intraoperative parameters. RESULTS: Overall, 1703 eyes of 1703 patients were included. Mean age was 48.3 ± 10.0 years, and 45.3% were male. Preoperatively, the steep group (2.4%, n = 41/1703) had steeper mean (44.6 D vs 43.1 D, P < .001) and steep (45.1 D vs 43.5 D, P < .001) keratometry, worse logMAR CDVA (0.07 vs 0.04, P = .02), and higher sphere (4.9 D vs 2.9 D, P < .001). Intraoperatively, they had a higher spherical treatment (4.6 D vs 2.8 D, P < .001). After hyperopic LASIK, the steep group had worse logMAR CDVA (0.10 vs 0.06, P = .01). However, after accounting for differences in baseline and spherical treatment, no significant differences were found in postoperative logMAR CDVA (0.06 vs 0.06, P = .99). The factors that remained associated with worse postoperative CDVA were higher spherical treatment (0.01 logMAR per 1 D, P < .001) and preoperative CDVA (0.60 logMAR per 1.00 logMAR, P < .001). CONCLUSIONS: Postoperative corneal steepness greater than 49 D is not associated with worse visual outcomes after hyperopic LASIK. However, lower preoperative visual potential and higher spherical treatment applied are associated with worse outcomes. The 49 D cutoff should be revisited.


Asunto(s)
Córnea , Hiperopía , Queratomileusis por Láser In Situ , Láseres de Excímeros , Refracción Ocular , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Hiperopía/cirugía , Hiperopía/fisiopatología , Agudeza Visual/fisiología , Estudios Retrospectivos , Persona de Mediana Edad , Masculino , Femenino , Córnea/fisiopatología , Láseres de Excímeros/uso terapéutico , Refracción Ocular/fisiología , Adulto , Periodo Posoperatorio , Topografía de la Córnea
10.
J Cataract Refract Surg ; 50(7): 767-776, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38353281

RESUMEN

Laser vision correction for residual refractive errors in patients with previous radial keratotomy (RK) presents a challenging task. Different techniques have been used with varying outcomes. This study aimed to systematically review published articles on refractive surgeries in post-RK patients by conducting a search on PubMed, Scopus, and Web of Science. The final analysis included 35 studies that described a total of 888 eyes. Our systematic review and meta-analysis demonstrated a significant improvement in uncorrected distance visual acuity (UDVA) for photorefractive keratectomy (PRK), topography-guided PRK, wavefront-guided PRK, and femtosecond laser-assisted in situ keratomileusis (LASIK) while mechanical microkeratome LASIK did not yield such significant improvements. Moreover, our results suggest that post-RK patients with hyperopia had a significant improvement in UDVA, whereas no such improvement was observed in patients with myopia.


Asunto(s)
Queratomileusis por Láser In Situ , Queratotomía Radial , Refracción Ocular , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Queratomileusis por Láser In Situ/métodos , Queratectomía Fotorrefractiva/métodos , Láseres de Excímeros/uso terapéutico , Errores de Refracción/fisiopatología , Miopía/cirugía , Miopía/fisiopatología , Hiperopía/cirugía , Hiperopía/fisiopatología
11.
J Refract Surg ; 40(1): e42-e47, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38190557

RESUMEN

PURPOSE: To identify factors predicting slow visual recovery following hyperopic laser in situ keratomileusis (LASIK). METHODS: The study included consecutive patients who underwent hyperopic LASIK between January 2005 and December 2019 at a single medical center. Patients were divided into two groups according to whether they experienced normal recovery of visual acuity (1-week visit) or slow visual recovery (1-month visit). Visual recovery was defined as achieving an efficacy index of 0.9 or greater. Efficacy index was calculated as postoperative uncorrected distance visual acuity / preoperative corrected distance visual acuity. A comparison of baseline and intraoperative parameters was performed. Binary logistic regression was performed to identify potential predictors of slow visual recovery. RESULTS: Overall, 861 eyes of 861 patients were included. Mean age was 48.0 ± 9.5 years and 55.9% were women. Two hundred forty-nine patients (28.9%) experienced slow visual recovery. Younger age (P = .01), a larger preoperative spherical equivalence (P = .002), and greater maximum ablation depth (P = .002) were predictors of slow visual recovery. In binary logistic regression, female gender (P = .036) and greater spherical equivalence (P = .007) remained significant predictors of slow visual recovery. CONCLUSIONS: Female gender and greater preoperative spherical equivalence were associated with slow visual recovery. Patients may be advised accordingly. [J Refract Surg. 2024;40(1):e42-e47.].


Asunto(s)
Hiperopía , Queratomileusis por Láser In Situ , Humanos , Femenino , Adulto , Persona de Mediana Edad , Masculino , Hiperopía/cirugía , Refracción Ocular , Agudeza Visual , Periodo Posoperatorio
12.
J Refract Surg ; 40(1): e42-e47, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38190563

RESUMEN

PURPOSE: To identify factors predicting slow visual recovery following hyperopic laser in situ keratomileusis (LASIK). METHODS: The study included consecutive patients who underwent hyperopic LASIK between January 2005 and December 2019 at a single medical center. Patients were divided into two groups according to whether they experienced normal recovery of visual acuity (1-week visit) or slow visual recovery (1-month visit). Visual recovery was defined as achieving an efficacy index of 0.9 or greater. Efficacy index was calculated as postoperative uncorrected distance visual acuity / preoperative corrected distance visual acuity. A comparison of baseline and intraoperative parameters was performed. Binary logistic regression was performed to identify potential predictors of slow visual recovery. RESULTS: Overall, 861 eyes of 861 patients were included. Mean age was 48.0 ± 9.5 years and 55.9% were women. Two hundred forty-nine patients (28.9%) experienced slow visual recovery. Younger age (P = .01), a larger preoperative spherical equivalence (P = .002), and greater maximum ablation depth (P = .002) were predictors of slow visual recovery. In binary logistic regression, female gender (P = .036) and greater spherical equivalence (P = .007) remained significant predictors of slow visual recovery. CONCLUSIONS: Female gender and greater preoperative spherical equivalence were associated with slow visual recovery. Patients may be advised accordingly. [J Refract Surg. 2024;40(1):e42-e47.].


Asunto(s)
Hiperopía , Queratomileusis por Láser In Situ , Humanos , Femenino , Adulto , Persona de Mediana Edad , Masculino , Hiperopía/cirugía , Refracción Ocular , Agudeza Visual , Periodo Posoperatorio
13.
BMC Ophthalmol ; 24(1): 13, 2024 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-38191381

RESUMEN

PURPOSE: To characterize the in vivo corneal epithelial thickness (CET) remodeling profile in a population of eyes after small incision lenticule intrastromal keratoplasty (SMI-LIKE) for hyperopia. METHODS: The CET profile was measured by RTVue-100 Fourier-domain OCT system across the central 6-mm diameter of the cornea of 17 eyes from 12 subjects (five males and seven females) who accepted corneal stromal lens implantation surgery for correcting hyperopia. The CET were measured at positions with a radius of 0-1.0 mm, 1.0-2.5 mm (divided into eight quadrants) and 2.5-3.0 mm (divided into eight quadrants) from the corneal center. Corneal maximum simulated keratometry (Km) was measured by Pentacam HR anterior segment analyzer to analyze CET changes. The examination data of subjects were collected in four time periods, which were preoperative, short-term postoperative (one week after surgery), mid-term postoperative (the last review within 3-6 months after surgery), and long-term postoperative (the last review over 1-2.5 years after surgery). The changes of CET were compared and analyzed in the four time periods. RESULTS: Mean CET in 0-1.0 mm, 1.0-2.5 mm and 2.5-3.0 mm of the cornea decreased in one week after surgery, respectively, as compared to CET in the preoperative period, which turned from 55.06 ± 0.82 µm、54.42 ± 0.75 µm、53.46 ± 0.60 µm to 51.18 ± 1.05 µm (P = 0.005), 49.38 ± 0.70 µm (P = 0.000), 51.29 ± 0.59 µm (P = 0.025). In the mid-term postoperative period, mean CET in 0-1.0 mm and 1.0-2.5 mm areas kept thinner than mean CET in the preoperative period, CET in 0-1.0 mm is 50.59 ± 0.76 µm (P = 0.000),CET in 1.0-2.5 mm is 50.23 ± 0.57 µm (P = 0.000), while mean CET in 2.5-3.0 mm area recovered to the same thickness as the preoperative level, which is 54.36 ± 0.66 µm (P = 1.000), until the long-term period, CET stabilized in the above doughnut pattern. CONCLUSIONS: After stromal lenticule implantation for hyperopia, CET showed a remodeled form of thinning in the 0-2.5 mm area and thickening in the 2.5-3.0 mm area, and remained stable within one year after surgery.


Asunto(s)
Trasplante de Córnea , Hiperopía , Femenino , Masculino , Humanos , Hiperopía/cirugía , Tomografía de Coherencia Óptica , Córnea , Sustancia Propia/cirugía
14.
Cornea ; 43(5): 598-602, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37713651

RESUMEN

PURPOSE: The aim of this study was to identify risk factors for the loss of corrected distance visual acuity (CDVA) after uncomplicated hyperopic laser-assisted in situ keratomileusis (LASIK). METHODS: A retrospective study including hyperopic patients who underwent microkeratome-assisted LASIK between January 2000 and December 2019 at Care-Vision Laser Centers, Tel-Aviv, Israel. Loss of CDVA was defined as ≥ 2 lines (0.20 logarithm of the minimum angle of resolution [logMAR] increase). Excluded were patients who had loss of CDVA because of intraoperative or postoperative complications or developed cataract at their final visit. RESULTS: Overall, 1998 eyes of 1998 patients were included in the study, of which 35 eyes (1.75%) had CDVA loss at final follow-up (mean 387 days). The vision-loss group had a significantly greater spherical treatment (3.4 vs. 2.8 D, P = 0.02), ablation depth (69.4 vs. 53.8 µm, P = 0.01), a higher proportion of treatments with a smaller optic zone (6.0 mm) (31.4% vs. 13.4%, P = 0.002), treatment with the EX200 (Alcon) excimer rather than the EX500 (Alcon) (74.3% vs. 39.0%, P < 0.001), and treatment with the Moria M2-90 microkeratome rather than the Moria Sub-Bowman's keratomileusis (SBK) microkeratome (65.7% vs. 29.6%, P < 0.001). In multivariate binary logistic regression, factors that remained significant predictors of CDVA loss were a greater spherical treatment (per 1 D treatment, odds ratio = 1.42, 95% CI, 1.11-1.81, P = 0.004) and the use of the Moria M2-90 microkeratome (odds ratio = 4.66, 95% CI, 2.30-9.45, P < 0.001). CONCLUSIONS: In patients undergoing uncomplicated hyperopic LASIK, a greater spherical hyperopic treatment is associated with a higher risk for vision loss. Transition to a newer microkeratome model significantly reduced vision loss rate.


Asunto(s)
Hiperopía , Queratomileusis por Láser In Situ , Humanos , Queratomileusis por Láser In Situ/efectos adversos , Estudios Retrospectivos , Córnea/cirugía , Agudeza Visual , Hiperopía/cirugía , Ceguera/etiología , Refracción Ocular , Resultado del Tratamiento , Láseres de Excímeros/uso terapéutico
16.
J Refract Surg ; 39(6): 366-373, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37306206

RESUMEN

PURPOSE: To evaluate and compare the incidence of transient light sensitivity syndrome (TLSS) after myopic laser in situ keratomileusis (LASIK), hyperopic LASIK, and myopic small incision lenticule extraction (SMILE). METHODS: A retrospective analysis was performed of consecutive LASIK and myopic SMILE cases, performed with the VisuMax femtosecond laser and MEL 80 or MEL 90 excimer laser (both Carl Zeiss Meditec AG) between January 2010 and February 2021 at London Vision Clinic, London, United Kingdom. A chart review was performed to find cases of clinically significant TLSS, identified as patients prescribed anti-inflammatory medications between 2 weeks and 6 months after surgery to manage photophobia. The incidence of TLSS was calculated for three groups: myopic SMILE, myopic LASIK, and hyperopic LASIK. The incidence of TLSS was then calculated for three subgroups within each treatment type based on spherical equivalent refraction treated. For myopic SMILE and myopic LASIK, it was 0.00 to -4.00 diopters (D) (low), -4.01 to -8.00 D (moderate), and -8.01 to -14.00 D (high). For hyperopic LASIK, it was 0.00 to +2.00 D (low), +2.01 to +4.00 D (moderate), and +4.01 to +6.50 D (high). RESULTS: The range of treatment for myopia was similar between the LASIK and SMILE groups. The incidence of TLSS was 1.2% for the myopic SMILE group, 5.3% for the myopic LASIK group, and 9.0% for the hyperopic LASIK group. The difference was statistically significant between all groups (P < .001). For myopic SMILE, the incidence of TLSS was independent of spherical equivalent refraction for low (1.4%), moderate (1.0%), and high (1.1%) myopia (P > .05). Similarly, for hyperopic LASIK, the incidence was similar for low (9.4%), moderate (8.7%), and high (8.7%) hyperopia (P > .05). In contrast, for myopic LASIK, the incidence of TLSS was "dose-dependent" on refractive error treated, with an incidence of 4.7% for low, 5.8% for moderate, and 8.1% for high myopia (P < .001). CONCLUSIONS: The incidence of TLSS was higher after myopic LASIK than after myopic SMILE, higher after hyperopic than myopic LASIK, and "dose-dependent" for myopic LASIK but did not vary by correction in myopic SMILE. This is the first report describing the phenomenon of late TLSS occurring between 8 weeks and 6 months after surgery, [J Refract Surg. 2023:39(6):366-373.].


Asunto(s)
Hiperopía , Queratomileusis por Láser In Situ , Miopía , Herida Quirúrgica , Humanos , Fotofobia/etiología , Hiperopía/cirugía , Incidencia , Estudios Retrospectivos , Miopía/cirugía
17.
J Cataract Refract Surg ; 49(9): 982-987, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37144644

RESUMEN

In this meta-analysis and systematic literature review of refractive outcomes after Descemet membrane endothelial keratoplasty (DMEK), the extent of the refractive shift and an overview of reasons for refractive shift after DMEK are provided. The PubMed library was screened for articles containing the terms "Descemet membrane endothelial keratoplasty," "DMEK," "Descemet membrane endothelial keratoplasty combined with cataract surgery," "triple-DMEK" combined with "refractive outcomes," "refractive shift," and "hyperopic shift." The refractive outcomes after DMEK were analyzed and compared using a fixed and random effects model. The overall mean change of the spherical equivalent outcome when compared with the preoperative value in cases of DMEK or when compared with the preoperative target refraction in cases of DMEK combined with cataract surgery was +0.43 diopters (D) (95% CI, 0.31-0.55). When DMEK is combined with cataract surgery, a target refraction of -0.5 D is recommended to achieve emmetropia. Changes in the posterior corneal curvature are identified as the main cause of the refractive hyperopic shift.


Asunto(s)
Catarata , Queratoplastia Endotelial de la Lámina Limitante Posterior , Distrofia Endotelial de Fuchs , Hiperopía , Humanos , Agudeza Visual , Queratoplastia Endotelial de la Lámina Limitante Posterior/efectos adversos , Refracción Ocular , Hiperopía/cirugía , Catarata/complicaciones , Estudios Retrospectivos , Distrofia Endotelial de Fuchs/cirugía , Distrofia Endotelial de Fuchs/complicaciones , Lámina Limitante Posterior/cirugía , Endotelio Corneal
18.
J Refract Surg ; 39(5): 319-325, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37162398

RESUMEN

PURPOSE: To compare the accuracy and outcomes of different intraocular lens (IOL) power calculation formulas in eyes with keratoconus undergoing cataract surgery with toric and non-toric IOLs. METHODS: This was a consecutive retrospective case series study including patients from the Cornea Service at the Department of Ophthalmology and Visual Sciences at the University of British Columbia, Vancouver, Canada, from 2000 to 2020. Keratoconus was diagnosed based on corneal topography and clinician opinion. Patients who underwent topography-guided photorefractive keratectomy, intracorneal ring segments implantation, or corneal transplant were excluded. The manifest spherical equivalent, prediction errors, and median absolute errors were calculated. Descriptive statistics were expressed as mean ± standard deviation. RESULTS: There were 160 eyes from 101 patients; 136 eyes received non-toric lenses and 24 eyes received toric lenses. Most patients had mild disease (< 48.00 diopters [D]) when stratified by steep keratometry values. Patients with severe disease (> 53.00 D) were significantly more hyperopic following surgery (P < .05). The Barrett Universal II (0.26 D, inter-quartile range [IQR] = 0.4), Holladay 2 (0.31, IQR = 1.2), and SRK/T (0.42, IQR = 0.86) formulas had the lowest median absolute error. The postoperative prediction error following toric lens insertion was not significantly different than following non-toric lens insertion, and the mean absolute astigmatism was significantly reduced with toric lenses. CONCLUSIONS: The Barrett Universal II, Holladay 2, and SRK/T were the most accurate IOL power calculation formulas in patients with keratoconus undergoing cataract surgery. Hyperopic surprise was increased in severe keratoconus. Toric IOLs may be considered in patients with mild keratoconus. [J Refract Surg. 2023;39(5):319-325.].


Asunto(s)
Astigmatismo , Catarata , Hiperopía , Queratocono , Lentes Intraoculares , Facoemulsificación , Humanos , Queratocono/complicaciones , Queratocono/cirugía , Implantación de Lentes Intraoculares , Estudios Retrospectivos , Agudeza Visual , Refracción Ocular , Astigmatismo/cirugía , Astigmatismo/diagnóstico , Hiperopía/cirugía
19.
Graefes Arch Clin Exp Ophthalmol ; 261(10): 3015-3022, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37199799

RESUMEN

AIM: This study aimed to evaluate the visual outcomes and corneal densitometry (CD) after allogenic lenticule intrastromal keratoplasty (AL-LIKE) and autologous lenticule intrastromal keratoplasty (AU-LIKE) for the correction of moderate-to-high hyperopia. METHODS: Ten subjects (14 eyes) underwent AL-LIKE and eight (8 eyes) underwent AU-LIKE. Patients were examined preoperatively and 1 day, 1 month, and 6 months postoperatively. The visual outcomes and CD for both surgical methods were evaluated. RESULTS: No postoperative complications were observed with either method. The efficacy index was 0.85±0.18 and 0.90±0.33 in the AL-LIKE and AU-LIKE groups, respectively. The safety indices were 1.07±0.21 and 1.25±0.37 in the AL-LIKE and AU-LIKE groups, respectively. The CD values of the anterior, central, and posterior layers in the AL-LIKE group increased significantly at 1 day postoperatively (all P < 0.05). The CD values of the anterior and central layers remained significantly higher than the preoperative values at 6 months postoperatively (all P < 0.05). The CD values of the anterior layer in the AU-LIKE group increased significantly 1 day postoperatively (all P < 0.05) and decreased to preoperative values (all P > 0.05) 1 month postoperatively. CONCLUSION: Both AL-LIKE and AU-LIKE exhibit good efficacy and safety in correcting hyperopia. However, AU-LIKE may have a smaller affected area and faster recovery time than those associated with AU-LIKE related to changes in corneal transparency.


Asunto(s)
Trasplante de Córnea , Hiperopía , Humanos , Sustancia Propia/cirugía , Hiperopía/diagnóstico , Hiperopía/cirugía , Agudeza Visual , Trasplante de Córnea/métodos , Densitometría
20.
BMC Ophthalmol ; 23(1): 219, 2023 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-37198622

RESUMEN

BACKGROUND: In eyes with hyperopia, astigmatism, and mixed astigmatism Transepithelial photorefractive keratectomy (TransPRK) is a modality of surface ablation surgery. We center on the corneal vertex for all our treatments (all have an offset to the center of the pupil) and wanted to compare the visual results of symmetrical profile treatments versus asymmetrical profile treatments (the center of the treatment on the vertex and the boundaries with the pupil center) using TransPRK as corneal refractive surgery. METHODS: We retrospectively analyzed two consecutive groups of eyes treated with TransPRK in the Aurelios Augenlaserzentrum Recklinghausen: 47 eyes treated with symmetrical offset and 51 eyes treated with asymmetrical offset. The intergroup comparisons were assessed using unpaired Student's T-tests, whereas preoperative to postoperative changes were assessed using paired Student's T-tests. RESULTS: Refractive outcomes were good for both groups. 83 and 88% of eyes were within the spherical equivalent of 0.5 D from the target in the symmetric and asymmetric offset groups, respectively. 85 and 84% of eyes had a postoperative astigmatism of 0.5 D or lower in the symmetric and asymmetric offset groups, respectively. CONCLUSION: We have not found a significant difference in the refractive outcomes between the symmetric group and the asymmetric group of eyes treated both with TransPRK for preoperatively hyperopic or mixed astigmatism.


Asunto(s)
Astigmatismo , Hiperopía , Queratectomía Fotorrefractiva , Humanos , Astigmatismo/cirugía , Agudeza Visual , Láseres de Excímeros/uso terapéutico , Estudios Retrospectivos , Refracción Ocular , Queratectomía Fotorrefractiva/métodos , Hiperopía/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA