Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 14.942
1.
JBJS Case Connect ; 14(2)2024 Apr 01.
Article En | MEDLINE | ID: mdl-38608127

CASE: This report describes a 25-year-old female professional triathlete with right external iliac artery endofibrosis (EIAE) that was definitively diagnosed on contrast-enhanced magnetic resonance images obtained immediately after treadmill running. The EIAE was treated by percutaneous transluminal angioplasty. By 8 weeks after surgery, she had no symptoms of claudication or pain in the right thigh after a 1-hour running session. There has been no recurrence in 1 year postoperatively. CONCLUSION: EIAE is a rare condition and difficult to diagnose in a timely manner because symptoms and radiographic imaging features appear only during intense exercise. Our patient was successfully treated with percutaneous transluminal angioplasty.


Iliac Artery , Vascular Diseases , Female , Humans , Adult , Iliac Artery/diagnostic imaging , Exercise , Pain , Lower Extremity
2.
J Cardiothorac Surg ; 19(1): 210, 2024 Apr 15.
Article En | MEDLINE | ID: mdl-38616244

Bilateral isolated common iliac artery aneurysms (CIAAs) are rare, and endovascular repair of CIAAs has emerged as an alternative to traditional open surgical repair. The primary goal of therapy is to exclude the aneurysm sac while maintaining perfusion of at least one internal iliac artery (IIA) to prevent pelvic ischemia. Although the iliac branch device (IBD) has improved the feasibility of preserving the IIA, its applicability is limited to a specific subset of aneurysm anatomy. We present a case series of three patients with bilateral isolated CIAAs in whom preoperative CT scans revealed an absence of a landing zone, the diameter of proximal CIA diameter was less than 13.0 mm, and normal diameter of the nonaneurysmal infrarenal aorta, making it challenging to use an IBD alone or a standard bifurcated aortic endograft to provide a proximal landing zone for iliac artery stenting. To overcome the small diameter of the infrarenal aorta, we implanted an aortic bifurcated unibody endograft. Then, we utilized a balloon-expandable covered stent-graft with overdilation as a modified sandwich technique to create an "eye of the tiger" configuration to prevent gutter leakage. The final angiography performed during the procedure revealed successful exclusion of the aneurysms, with blood flow to the right IIA and no type III endoleak. During the postoperative follow-up period, no patients exhibited symptoms associated with pelvic ischemia. There were no endoleaks or sac expansions on the two-year follow-up CT scans, and all external and internal iliac graft limbs were patent. This study demonstrated that a combination of an aortic bifurcated unibody endograft and a modified sandwich technique can effectively treat bilateral isolated CIAAs with certain anatomical constraints.


Endovascular Procedures , Iliac Aneurysm , Humans , Iliac Artery , Iliac Aneurysm/surgery , Angiography , Endoleak , Ischemia
3.
J Cardiovasc Surg (Torino) ; 65(2): 85-98, 2024 Apr.
Article En | MEDLINE | ID: mdl-38635284

Endovascular aortic repair (EVAR) is nowadays the establishment treatment for patients with abdominal aortic aneurysm (AAA) both in elective and urgent setting. Despite the large applicability and satisfactory results, the presence of hostile iliac anatomy affects both technical and clinical success. This narrative review aimed to report the impact of iliac access and related adjunctive procedures in patients undergoing EVAR in elective and non-elective setting. Hostile iliac access can be defined in presence of narrowed, tortuous, calcified, or occluded iliac arteries. These iliac characteristics can be graded by the anatomic severity grade score to quantitatively assess anatomic complexity before undergoing treatment. Literature shows that iliac hostility has an impact on device navigability, insertion and perioperative and postoperative results. Overall, it has been correlated to higher rate of access issues, representing up to 30% of the first published EVAR experience. Recent innovations with low-profile endografts have reduced large-bore sheaths related issues. However, iliac-related complications still represent an issue, and several adjunctive endovascular and surgical strategies are nowadays available to overcome these complications during EVAR. In urgent settings iliac hostility can significantly impact on particular time sensitive procedures. Moreover, in case of severe hostility patients might be written off for EVAR repair might be inapplicable, exposing to higher mortality/morbidity risk in this urgent/emergent setting. In conclusion, an accurate anatomical evaluation of iliac arteries during preoperative planning, materials availability, and skilled preparation to face iliac-related issues are crucial to address these challenges.


Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Elective Surgical Procedures , Endovascular Procedures , Iliac Artery , Humans , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Iliac Artery/surgery , Iliac Artery/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Treatment Outcome , Risk Factors , Blood Vessel Prosthesis , Postoperative Complications/etiology
4.
BMJ Case Rep ; 17(4)2024 Apr 08.
Article En | MEDLINE | ID: mdl-38589247

Corona mortis (CM) is an anastomotic vessel between the inferior epigastric or external iliac vessels and the obturator or internal iliac vessels. The Latin meaning of it is 'crown of death' which corresponds to massive haemorrhage caused by injury to this vessel during surgery. The incidence of this vessel is around 50% in the hemipelvis. We are presenting an intraoperative video of a right laparoscopic totally extraperitoneal mesh hernioplasty demonstrating a CM artery in the right hemipelvis. Care was taken to prevent injury to this vessel. CO2 insufflation pressure was reduced to less than 10 mm Hg to see any venous variant of this vessel. Carefully, polypropylene mesh was placed without a fixation device. Anatomical knowledge of the CM vessel is therefore essential in preventing injury for surgeons who approach the inguinal and retropubic regions.


Hernia, Inguinal , Laparoscopy , Humans , Iliac Artery/surgery , Herniorrhaphy , Surgical Mesh/adverse effects , Arteries/surgery , Hernia, Inguinal/surgery
5.
Innovations (Phila) ; 19(2): 192-195, 2024.
Article En | MEDLINE | ID: mdl-38606852

OBJECTIVE: Femoral artery cannulation is the most commonly used approach for cardiopulmonary bypass (CPB) in robotic cardiac procedures. However, without adding a distal perfusion cannula, leg ischemia can occur in up to 11.5% of patients. There is a well-described 2 to 4 mm size arterial branch that originates from the medial side of the external iliac artery or inferior epigastric artery, immediately above the inguinal ligament, and connects to the obturator artery. Therefore, it was historically named the corona mortis, which means "crown of death" in Latin. When peripheral cannulation is performed above this branch in the external iliac artery, we consider it a corona "vitae" because of its role as a limb-saving collateral. We report herein our standard technique of peripheral cannulation without the need of a distal perfusion cannula and preventing limb ischemia. METHODS: We included all patients who underwent robotic cardiac surgery with peripheral cannulation over a 16-month period at our institution. We cannulated just above the level of the inguinal ligament through a 2 to 3 cm transverse skin incision. The incidence of limb ischemia and vascular complications was recorded and analyzed. RESULTS: During the study period, 133 patients underwent robotic cardiac procedures with peripheral "external iliac" CPB. The size of the cannula was 21F or larger in 73% and 23F in 54% of the patients. No leg ischemia or femoral artery complications requiring additional intervention occurred. CONCLUSIONS: External iliac cannulation can be successfully performed in robot-assisted cardiac surgery using relatively large cannulas without the need of a distal limb perfusion catheter, with good results. In our view, given the importance of the corona mortis ("crown of death" in Latin) in perfusing the limb during CPB, we propose a new name for this artery in robotic cardiac surgery, namely, the corona vitae ("crown of life" in Latin).


Iliac Artery , Robotic Surgical Procedures , Humans , Iliac Artery/surgery , Robotic Surgical Procedures/methods , Male , Female , Aged , Cardiac Surgical Procedures/methods , Cardiopulmonary Bypass/methods , Middle Aged , Ischemia/prevention & control , Catheterization, Peripheral/methods , Femoral Artery/surgery , Catheterization/methods
6.
Korean J Gastroenterol ; 83(4): 167-171, 2024 Apr 25.
Article En | MEDLINE | ID: mdl-38659254

The occurrence of an abdominal wall hematoma caused by abdominal paracentesis in patients with liver cirrhosis is rare. This paper presents a case of an abdominal wall hematoma caused by abdominal paracentesis in a 67-year-old woman with liver cirrhosis with a review of the relevant literature. Two days prior, the patient underwent abdominal paracentesis for symptom relief for refractory ascites at a local clinic. Upon admission, a physical examination revealed purpuric patches with swelling and mild tenderness in the left lower quadrant of the abdominal wall. Abdominal computed tomography revealed advanced liver cirrhosis with splenomegaly, tortuous dilatation of the para-umbilical vein, a large volume of ascites, and a large acute hematoma at the left lower quadrant of the abdominal wall. An external iliac artery angiogram showed the extravasation of contrast media from the left deep circumflex iliac artery. Embolization of the target arterial branches using N-butyl-2-cyanoacrylate was then performed, and the bleeding was stopped. The final diagnosis was an abdominal wall hematoma from the left deep circumflex iliac artery after abdominal paracentesis in a patient with liver cirrhosis.


Abdominal Wall , Embolization, Therapeutic , Hematoma , Iliac Artery , Liver Cirrhosis , Paracentesis , Tomography, X-Ray Computed , Humans , Female , Aged , Hematoma/etiology , Hematoma/diagnosis , Hematoma/therapy , Liver Cirrhosis/complications , Iliac Artery/diagnostic imaging , Angiography , Ascites/etiology , Ascites/therapy
7.
Medicine (Baltimore) ; 103(14): e37731, 2024 Apr 05.
Article En | MEDLINE | ID: mdl-38579061

RATIONALE: A hostile iliac access route is an important consideration when enforcing endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA). Herein, we report a case of AAA with unilateral external iliac artery occlusion, for which bifurcated EVAR was successfully performed using a single femoral and brachial artery access. PATIENT CONCERNS: A 76-year-old man who had undergone surgery for lung cancer 4.5 years prior was diagnosed AAA by computed tomography (CT). DIAGNOSIS: Two and a half years before presentation, CT revealed an infrarenal 48 mm AAA, which had enlarged to 57 mm by 2 months preoperatively. CT identified occlusion from the right external iliac artery to the right common femoral artery, with no observed ischemic symptoms in his right leg. The right external iliac artery, occluded and atrophied, had a 1 to 2 mm diameter. INTERVENTION: Surgery was commenced with the selection of a Zenith endovascular graft (Cook Medical) with an extended body length. Two Gore Viabahn VBX balloon expandable endoprosthesis (VBX; W.L. Gore & Associate) were delivered from the right axilla as the contralateral leg. OUTCOMES: CT scan on the 2nd day after surgery revealed no endoleaks. LESSONS: While the long-term results remain uncertain, this method may serve as an option for EVAR in patients with unilateral external iliac artery occlusion.


Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Iliac Aneurysm , Male , Humans , Aged , Aortic Aneurysm, Abdominal/complications , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/methods , Iliac Artery/diagnostic imaging , Iliac Artery/surgery , Axilla/surgery , Leg/surgery , Endovascular Procedures/methods , Stents , Treatment Outcome , Iliac Aneurysm/surgery
8.
Langenbecks Arch Surg ; 409(1): 135, 2024 Apr 23.
Article En | MEDLINE | ID: mdl-38649506

OBJECTIVE: Endovascular repair is the preferred treatment for aortoiliac aneurysm, with preservation of at least one internal iliac artery recommended. This study aimed to assess pre-endovascular repair anatomical characteristics of aortoiliac aneurysm in patients from the Global Iliac Branch Study (GIBS, NCT05607277) to enhance selection criteria for iliac branch devices (IBD) and improve long-term outcomes. METHODS: Pre-treatment CT scans of 297 GIBS patients undergoing endovascular aneurysm repair were analyzed. Measurements included total iliac artery length, common iliac artery length, tortuosity index, common iliac artery splay angle, internal iliac artery stenosis, calcification score, and diameters in the device's landing zone. Statistical tests assessed differences in anatomical measurements and IBD-mediated internal iliac artery preservation. RESULTS: Left total iliac artery length was shorter than right (6.7 mm, P = .0019); right common iliac artery less tortuous (P = .0145). Males exhibited greater tortuosity in the left total iliac artery (P = .0475) and larger diameter in left internal iliac artery's landing zone (P = .0453). Preservation was more common on right (158 unilateral, 34 bilateral) than left (105 unilateral, 34 bilateral). There were 192 right-sided and 139 left-sided IBDs, with 318 IBDs in males and 13 in females. CONCLUSION: This study provides comprehensive pre-treatment iliac anatomy analysis in patients undergoing endovascular repair with IBDs, highlighting differences between sides and sexes. These findings could refine patient selection for IBD placement, potentially enhancing outcomes in aortoiliac aneurysm treatment. However, the limited number of females in the study underscores the need for further research to generalize findings across genders.


Endovascular Procedures , Iliac Aneurysm , Humans , Male , Female , Iliac Aneurysm/surgery , Iliac Aneurysm/diagnostic imaging , Aged , Endovascular Procedures/methods , Middle Aged , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/pathology , Iliac Artery/diagnostic imaging , Blood Vessel Prosthesis Implantation/methods , Aged, 80 and over , Tomography, X-Ray Computed , Treatment Outcome
9.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(2): 351-359, 2024 Apr 25.
Article Zh | MEDLINE | ID: mdl-38686417

In this work, we investigated the influence of the bifurcation geometry of the iliac artery on the propagation properties of the pulse wave, and applied software to establish the straight bifurcation and curved bifurcation bi-directional fluid-solid coupling finite element analysis models based on the iliac artery, and compared and analyzed the influence of the bifurcation angle of the blood vessel on the propagation characteristics of the pulse wave. It was found that the bifurcation geometry had a significant effect on the pulse wave propagation in the iliac arteries, and the pressure and velocity pulse wave amplitudes predicted by these two models had a good agreement with that before the vessel bifurcation in a cardiac cycle. The curvilinear bifurcation model predicted the pulse wave amplitude to be lower and the pressure drop to be smaller after the bifurcation, which was more in line with the actual situation of the human body. In addition, the bifurcation point is accompanied by the stress concentration phenomenon in the vessel wall, and there is a transient increase in the velocity pulse waveform amplitude, which was consistent with the fact that the bifurcation site is prone to phenomena such as arterial stenosis and hardening. The preliminary results of this paper will provide some reference for the use of pulse waveforms in the diagnosis of arterial diseases.


Finite Element Analysis , Iliac Artery , Models, Cardiovascular , Pulse Wave Analysis , Humans , Iliac Artery/physiology , Blood Pressure/physiology , Pulsatile Flow/physiology , Blood Flow Velocity/physiology , Computer Simulation
11.
Microsurgery ; 44(4): e31171, 2024 May.
Article En | MEDLINE | ID: mdl-38549389

BACKGROUND: With the growing demand for the use of thin perforator flaps, obtaining knowledge on the superficial anatomy of perforators is imperative for stable flap elevation. Conventional modalities for perforator mapping fall short in providing such information. High-frequency ultrasound (HFUS), known for visualizing the superficially located anatomic structures, may potentially fill this void. This study aimed to evaluate the effectiveness of HFUS in the outcome of anterolateral thigh (ALT) and superficial circumflex iliac artery perforator (SCIP) flap-based reconstructions. METHODS: Consecutive patients who underwent free ALT or SCIP flap-based reconstruction from January 2021 to November 2022 were retrospectively reviewed. Perforator mapping was conducted using a handheld Doppler during the first year, while HFUS was used in the latter part. The two techniques were compared in terms of flap harvesting time and perfusion-related complication rates while considering the flap elevation plane. RESULTS: In total, 123 cases were analyzed, including 82 ALT flaps (41 in each group) and 41 SCIP flaps (16 in the Doppler and 25 in the HFUS group). The time required for flap elevation exhibited a tendency to decrease in the HFUS group, with a significant difference observed in cases involving thin flap elevation (super-thin ALT flaps and pure-skin-perforator SCIP flaps). Compared with the Doppler group, the HFUS group demonstrated significantly lower rates of PRCs, particularly partial flap necrosis. This difference remained significant in multivariable analyses. CONCLUSION: Our results suggest that HFUS might be an appealing modality for perforator mapping in cases requiring thin ALT and SCIP flap.


Perforator Flap , Plastic Surgery Procedures , Humans , Perforator Flap/blood supply , Thigh/surgery , Thigh/blood supply , Iliac Artery/surgery , Retrospective Studies
12.
Hand Clin ; 40(2): 179-187, 2024 May.
Article En | MEDLINE | ID: mdl-38553089

The superficial circumflex iliac artery perforator (SCIP) flap is thin, pliable tissue well suited for reconstruction of injuries of the hand and upper extremity. Based upon perforators from the superficial circumflex iliac artery, the SCIP flap has advantages over the traditional groin flap due to reduced need for secondary procedures and improved donor site morbidity This article offers a detailed exploration of the SCIP flap design and technique, its advantages over traditional methods, and its potential applications in reconstructive surgery. Post-operative care and critical points are also discussed, and case examples are provided to guide readers through the intricacies of the technique, emphasizing the surgical skill and precision required for successful implementation.


Perforator Flap , Plastic Surgery Procedures , Humans , Perforator Flap/blood supply , Iliac Artery/surgery , Upper Extremity/surgery , Hand/surgery
13.
Head Neck ; 46(6): 1428-1438, 2024 Jun.
Article En | MEDLINE | ID: mdl-38533771

BACKGROUND: Head and neck tissue defects after ablative surgery often require complex and composite reconstructions. The superficial circumflex iliac artery perforator (SCIP) flap is an extremely versatile perforator-based flap with minimal donor site morbidity, which may represent the optimal procedure in this setting. Over the last 5 years, we collected a large base of experience, including both simple and chimeric SCIP-based reconstruction, making this flap our first choice for head and neck reconstructions. PATIENTS AND METHODS: Seventy-three patients undergoing ablative head and neck surgery for oncologic pathologies were treated by means of a SCIP flap reconstruction. Patients' mean age was 67 years old (range 37-89), 51 were males and 22 were females. Fifty-eight flaps were simple and 15 were chimeric reconstruction patterns. Indocyanine green perfusion imaging was performed in all cases. RESULTS: All the patients were successfully treated with no flap losses were encountered. Twelve patients encountered postoperative complications: in four cases revision surgery was required for venous congestion, while the remaining cases were managed conservatively (four wound dehiscence and three infections). No patients showed donor site complications. The mean follow-up period was 11 months (range 3-24). CONCLUSIONS: Our case series demonstrates the reliability and versatility of the SCIP flap for different kinds of head and neck reconstructions. The chimeric options combined with bone, double skin paddle, and muscle offer a broad variety of functional reconstructive solutions for complex head and neck surgeries. Intraoperative indocyanine green perfusion examination provides a valuable tool to assess and ascertain proper vascularization and post-anastomosis vessel patency in complex microvascular flap-based reconstructions.


Head and Neck Neoplasms , Iliac Artery , Perforator Flap , Plastic Surgery Procedures , Humans , Female , Male , Aged , Middle Aged , Plastic Surgery Procedures/methods , Head and Neck Neoplasms/surgery , Adult , Aged, 80 and over , Perforator Flap/blood supply , Iliac Artery/surgery , Treatment Outcome , Free Tissue Flaps/blood supply , Retrospective Studies
17.
Khirurgiia (Mosk) ; (3): 21-28, 2024.
Article Ru | MEDLINE | ID: mdl-38477240

OBJECTIVE: To compare the short-term and long-term outcomes of hybrid interventions after various infrainguinal reconstructions (restoration of blood flow through superficial femoral artery and pulsatile blood flow through deep femoral artery) in patients with iliac-femoral arterial disease. MATERIAL AND METHODS: A retrospective analysis included patients after hybrid iliac-femoral interventions between 2014 and 2018. These interventions included stenting of iliac arteries and various open infrainguinal reconstructions. The first group (n=41) consisted of patients who underwent reconstruction of superficial femoral artery, the second group (n=88) - restoration of pulsatile blood flow in deep femoral artery. We analyzed the Rutherford score, perioperative complications, primary patency rates and limb salvage rates after 12 months in both groups. RESULTS: Significant improvement (Rutherford score +3) was achieved in 28 (70%) and 14 (15.9%) patients, respectively (p<0.05). There were no significant between-group differences in the number of postoperative complications. Surgery time was longer in the first group (median 160 and 130 min, respectively, p<0.05). However, intraoperative blood loss was similar. Primary patency rates after 12 months were 82.4% and 95.1%, respectively (p=0.054). Limb salvage rates after 12 months were 94.7% and 100%, respectively (p<0.05). CONCLUSION: This study highlights the potential advantages of restoring pulsatile blood flow through the deep femoral artery in hybrid interventions. Higher primary patency and limb salvage rates in the second group indicate better long-term outcomes after restoration of blood flow through the deep femoral artery. Further prospective studies are needed to confirm these results and determine the underlying mechanisms of differences.


Arterial Occlusive Diseases , Femoral Artery , Humans , Retrospective Studies , Vascular Patency , Femoral Artery/surgery , Iliac Artery/surgery , Limb Salvage , Stents , Treatment Outcome , Arterial Occlusive Diseases/surgery , Risk Factors
19.
Microsurgery ; 44(2): e31138, 2024 Feb.
Article En | MEDLINE | ID: mdl-38343009

Following its initial description by Koshima in 2004, the superficial circumflex iliac artery perforator (SCIP) flap has become a ubiquitous and extremely useful flap in coverage of defects whereby bulkiness must be avoided. It also allows direct closure and concealment of the donor site. Its use as a free tissue transfer has been demonstrated by various surgeons globally. Nevertheless, there are few cases illustrating the utility of the pedicled SCIP flap in the reconstruction of lower abdominal defects. We present a case of a pedicled SCIP flap utilized as a chimeric flap incorporating external oblique muscle fascia on a deep branch along with the typical fasciocutaneous component based on the superficial branch to cover the suprapubic defect after vesicocutaneous fistula repair. We thereafter report on the literature of pedicled chimeric SCIP flap for locoregional reconstruction. A 26-year-old female was referred to the Plastic and Reconstructive Surgery unit after suffering a functional bladder outlet obstruction necessitating the creation of a urinary stoma. Subsequently, stoma obstruction occurred, and a suprapubic catheter was performed that was complicated by infection and resulted in the development of a vesicocutaneous fistula. Accordingly, the urological surgeons were planning surgical closure of the suprapubic vesicocutaneous defect, measuring 5 × 4 cm. A pedicled SCIP flap was designed to match the defect size; and raised as a chimeric flap with external oblique muscle fascia based on the deep branch, along with the fasciocutaneous component based on the superficial branch. The external oblique fascial component was used to secure the suture line of fistula repair, over which the fasciocutaneous component was inset, effectively double breasting the fistula repair and full thickness lower abdominal defect. The patient had an unremarkable postoperative recovery and has since been followed up in the outpatient setting without complication for the past 24 months. Robust coverage of the suprapubic defect was reliably achieved and no further fistulation has occurred. This case illustrates that a pedicled SCIP flap can be harvested as a chimeric flap and used to reliably cover defects in the infra-umbilical region.


Fistula , Perforator Flap , Plastic Surgery Procedures , Female , Humans , Adult , Iliac Artery/surgery , Urinary Bladder/surgery , Perforator Flap/blood supply , Fascia
20.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Article En | MEDLINE | ID: mdl-38321257

Anomalous left coronary artery originating from the pulmonary artery (ALCAPA) is an infrequent congenital anomaly. Presentation of this syndrome is rare in adults. Nevertheless, adult patients are at risk of ischaemia, arrhythmias or sudden cardiac death and always require surgical intervention. At our institution, a specific technique of interposition of the right internal iliac artery as a free-graft for left coronary artery reimplantation was used in adult ALCAPA patients. The aim of this report is to determine long-term results and experiences with this surgical technique.


Anomalous Left Coronary Artery , Bland White Garland Syndrome , Coronary Vessel Anomalies , Adult , Humans , Bland White Garland Syndrome/surgery , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/surgery , Pulmonary Artery/abnormalities , Iliac Artery/diagnostic imaging , Iliac Artery/surgery , Replantation , Coronary Vessel Anomalies/diagnostic imaging , Coronary Vessel Anomalies/surgery
...