Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
Arthritis Rheumatol ; 70(10): 1610-1616, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29749720

RESUMEN

OBJECTIVE: Autoantibodies are clinically useful for phenotyping patients across the spectrum of autoimmune rheumatic diseases. Using serum from a patient with Sjögren's syndrome (SS), we detected a new specificity by immunoblotting. This study was undertaken to identify this autoantibody and to evaluate its disease specificity. METHODS: A prominent 40-kd band was detected when immunoblotting was performed using SS patient serum and lysate from rat dorsal root ganglia (DRGs). Using 2-dimensional gel electrophoresis and liquid chromatography tandem mass spectrometry peptide sequencing, the autoantigen was identified as calponin 3. Anti-calponin 3 antibodies were evaluated in sera from patients with primary SS (n = 209), patients with systemic lupus erythematosus (SLE; n = 138), patients with myositis (n = 138), patients with multiple sclerosis (MS; n = 44), and healthy controls (n = 46) by enzyme-linked immunosorbent assay. Expression of calponin 3 was assessed by immunohistochemistry. RESULTS: Calponin 3 was identified as a new autoantigen. Anti-calponin 3 antibodies were detected in 23 (11.0%) of the 209 SS patients, 12 (8.7%) of the 138 SLE patients, 7 (5.1%) of the 138 myositis patients, 3 (6.8%) of the 44 MS patients, and 1 (2.2%) of the 46 healthy controls. Among SS patients, the frequency of anti-calponin 3 antibodies was highest in those with neuropathies (7 [17.9%] of 39). In this subset, the frequency of anti-calponin 3 antibodies differed significantly from that in the control group (P = 0.02). Calponin 3 was expressed primarily in rat DRG perineuronal satellite cells but not neurons. CONCLUSION: Calponin 3 is a novel autoantigen. Antibodies against this protein are found in SS and associate with the subset of patients experiencing neuropathies. Intriguingly, we found that calponin 3 is expressed in DRG perineuronal satellite cells, suggesting that these may be a target in SS.


Asunto(s)
Autoanticuerpos/sangre , Proteínas de Unión al Calcio/inmunología , Immunoblotting/estadística & datos numéricos , Proteínas de Microfilamentos/inmunología , Síndrome de Sjögren/sangre , Síndrome de Sjögren/inmunología , Adulto , Anciano , Animales , Autoanticuerpos/inmunología , Biomarcadores/sangre , Estudios Transversales , Femenino , Ganglios Espinales/inmunología , Humanos , Lupus Eritematoso Sistémico/sangre , Lupus Eritematoso Sistémico/inmunología , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/sangre , Esclerosis Múltiple/inmunología , Miositis/sangre , Miositis/inmunología , Ratas , Sensibilidad y Especificidad , Calponinas
2.
PLoS One ; 11(2): e0149575, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26908370

RESUMEN

Experimental measurements require calibration to transform measured signals into physically meaningful values. The conventional approach has two steps: the experimenter deduces a conversion function using measurements on standards and then calibrates (or normalizes) measurements on unknown samples with this function. The deduction of the conversion function from only the standard measurements causes the results to be quite sensitive to experimental noise. It also implies that any data collected without reliable standards must be discarded. Here we show that a "1-step calibration method" reduces these problems for the common situation in which samples are measured in batches, where a batch could be an immunoblot (Western blot), an enzyme-linked immunosorbent assay (ELISA), a sequence of spectra, or a microarray, provided that some sample measurements are replicated across multiple batches. The 1-step method computes all calibration results iteratively from all measurements. It returns the most probable values for the sample compositions under the assumptions of a statistical model, making them the maximum likelihood predictors. It is less sensitive to measurement error on standards and enables use of some batches that do not include standards. In direct comparison of both real and simulated immunoblot data, the 1-step method consistently exhibited smaller errors than the conventional "2-step" method. These results suggest that the 1-step method is likely to be most useful for cases where experimenters want to analyze existing data that are missing some standard measurements and where experimenters want to extract the best results possible from their data. Open source software for both methods is available for download or on-line use.


Asunto(s)
Calibración , Interpretación Estadística de Datos , Immunoblotting/estadística & datos numéricos , Programas Informáticos , Ensayo de Inmunoadsorción Enzimática , Immunoblotting/normas , Modelos Estadísticos , Proteínas/análisis , Proteínas/inmunología , Reproducibilidad de los Resultados , Flujo de Trabajo
3.
J Neurosci Methods ; 208(1): 86-91, 2012 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-22579877

RESUMEN

In the present study, we applied the principles of immunoblotting and light microscopy immunohistochemistry to develop a combined methodology that allows obtaining optical density data in films, as well as morphological and protein distribution data on slides using the same brain tissue section, thus maximizing the data obtained from a single sample. This is especially important when experiments are performed using very valuable or unique tissue samples, which is a very common case in the study of the human brain. The ideal methodology should combine the possibility of measuring levels of expression of a marker, and the capability to map accurately the distribution of that marker in the region of interest. To achieve this, two things are required: first, the technique needs to be sensitive enough to obtain optical density or intensity measurements of the marker, and second, a good preservation of the tissue is needed for the study of distribution patterns and morphological analysis. Here we show that our combined methodology produced reliable results for different tissue preservation conditions (fresh-frozen and fixed tissue), in different species (rat and human), in different brain areas (substantia nigra and striatum), and for the detection of different markers (tyrosine hydroxylase and µ-opioid receptor). This methodology also combines the accuracy of optical density data acquisition in film with obtaining histological slides from the same sample. In summary, the methodology proposed here is very versatile and does not require the use of specialized equipment, other than the routine equipment present in an anatomy laboratory.


Asunto(s)
Dosimetría por Película/instrumentación , Dosimetría por Película/métodos , Immunoblotting/instrumentación , Immunoblotting/estadística & datos numéricos , Microscopía/instrumentación , Microscopía/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Integración de Sistemas
4.
Biosens Bioelectron ; 26(11): 4624-7, 2011 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-21641786

RESUMEN

The zoonotic protozoan parasite Cryptosporidium parvum poses a significant risk to public health. Due to the low infectious dose of C. parvum, remarkably sensitive detection methods are required for water and food industries analysis. However PCR affirmed sensing method of the causative nucleic acid has numerous advantages, still criterion demands for simple techniques and expertise understanding to extinguish its routine use. In contrast, protein based immuno detecting techniques are simpler to perform by a commoner, but lack of sensitivity due to inadequate signal amplification. In this paper, we focused on the development of a mere sensitive immuno detection method by coupling anti-cyst antibody and alkaline phosphatase on gold nanoparticle for C. parvum is described. Outcome of the sensitivity in an immuno-dot blot assay detection is enhanced by 500 fold (using conventional method) and visually be able to detect up to 10 oocysts/mL with minimal processing period. Techniques reported in this paper substantiate the convenience of immuno-dot blot assay for the routine screening of C. parvum in water/environmental examines and most importantly, demonstrates the potential of a prototype development of simple and inexpensive diagnostic technique.


Asunto(s)
Cryptosporidium parvum/aislamiento & purificación , Immunoblotting/métodos , Fosfatasa Alcalina , Animales , Anticuerpos Inmovilizados , Anticuerpos Antiprotozoarios , Secuencia de Bases , Cryptosporidium parvum/genética , Cryptosporidium parvum/inmunología , Cryptosporidium parvum/patogenicidad , ADN Protozoario/genética , Oro , Humanos , Immunoblotting/estadística & datos numéricos , Límite de Detección , Nanopartículas del Metal , Oocistos/inmunología , Agua/parasitología
5.
Ann Neurol ; 69(1): 34-46, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21280074

RESUMEN

OBJECTIVE: The 5-lipoxygenase (5-LO) enzymatic pathway is widely distributed within the central nervous system, and is upregulated in Alzheimer's disease. However, the mechanism whereby it may influence the disease pathogenesis remains elusive. METHODS: We evaluated the molecular mechanism by which 5-LO regulates amyloid ß (Aß) formation in vitro and in vivo by pharmacological and genetic approaches. RESULTS: Here we show that 5-LO regulates the formation of Aß by activating the cAMP-response element binding protein (CREB), which in turn increases transcription of the γ-secretase complex. Preventing CREB activation by pharmacologic inhibition or dominant negative mutants blocks the 5-LO-dependent elevation of Aß formation and the increase of γ-secretase mRNA and protein levels. Moreover, 5-LO targeted gene disruption or its in vivo selective pharmacological inhibition results in a significant reduction of Aß, CREB and γ-secretase levels. INTERPRETATION: These data establish a novel functional role for 5-LO in regulating endogenous formation of Aß levels in the central nervous system. Thus, 5-LO pharmacological inhibition may be beneficial in the treatment and prevention of Alzheimer's disease.


Asunto(s)
Péptidos beta-Amiloides/biosíntesis , Péptidos beta-Amiloides/efectos de los fármacos , Araquidonato 5-Lipooxigenasa/farmacología , Enfermedad de Alzheimer/enzimología , Enfermedad de Alzheimer/genética , Enfermedad de Alzheimer/metabolismo , Secretasas de la Proteína Precursora del Amiloide/efectos de los fármacos , Secretasas de la Proteína Precursora del Amiloide/metabolismo , Péptidos beta-Amiloides/metabolismo , Precursor de Proteína beta-Amiloide/genética , Precursor de Proteína beta-Amiloide/metabolismo , Animales , Sistema Nervioso Central/metabolismo , Factores Quimiotácticos , Proteína de Unión a Elemento de Respuesta al AMP Cíclico/metabolismo , Activación Enzimática/efectos de los fármacos , Femenino , Humanos , Ácidos Hidroxieicosatetraenoicos/biosíntesis , Ácidos Hidroxieicosatetraenoicos/metabolismo , Immunoblotting/métodos , Immunoblotting/estadística & datos numéricos , Leucotrienos/biosíntesis , Ácidos Linoleicos , Inhibidores de la Lipooxigenasa/metabolismo , Inhibidores de la Lipooxigenasa/farmacología , Ratones , Mutación/genética , Neuroblastoma , Factores de Transcripción/metabolismo , Transfección , Células Tumorales Cultivadas , Regulación hacia Arriba/efectos de los fármacos
6.
Nat Protoc ; 5(1): 14-9, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20010723

RESUMEN

The fusion peptide of influenza virus hemagglutinin (HA) has a critical role in mediating the entry of the virus into the cells and is also the only universally conserved sequence in the HAs of all strains of influenza A and influenza B viruses. Therefore, it could be an attractive target for new vaccine development and a potency marker for existing influenza vaccines. The fusion peptide epitope is hidden inside the HA proteins, making it inaccessible for quantitative antibody binding. Our simple slot blot protocol highlights pre-treatment of HA samples with moderate concentrations of denaturant to maximally expose the fusion peptide on the protein surface, followed by detection using universal antibodies targeting the fusion peptide. The method is highly reliable, inexpensive and easy to follow. The entire procedure takes only 5 h and can be applied to the quantitative determination of virtually all influenza viral HAs using a single antibody targeting the fusion peptide.


Asunto(s)
Glicoproteínas Hemaglutininas del Virus de la Influenza/análisis , Immunoblotting/métodos , Virus de la Influenza A/química , Anticuerpos Antivirales , Secuencia Conservada , Epítopos/análisis , Epítopos/genética , Glicoproteínas Hemaglutininas del Virus de la Influenza/genética , Glicoproteínas Hemaglutininas del Virus de la Influenza/inmunología , Humanos , Immunoblotting/estadística & datos numéricos , Inmunodifusión/métodos , Virus de la Influenza A/genética , Virus de la Influenza A/inmunología , Vacunas contra la Influenza/química , Vacunas contra la Influenza/genética , Vacunas contra la Influenza/inmunología
7.
Anaesth Intensive Care ; 36(5): 654-8, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18853582

RESUMEN

The soluble triggering receptor expressed on myeloid cells (sTREM)-1 has emerged as a potentially useful biomarker for the diagnosis of sepsis. This study aimed to evaluate the prognostic utility of serum sTREM-1 in septic shock, in comparison with that of procalcitonin measurements. Thirty-one consecutive patients in a tertiary medical intensive care unit with septic shock were studied. sTREM-1 levels in blood were measured using a modified immunoblot array technique on days one to three of intensive care unit admission. Serum procalcitonin and interleukin (IL)-1beta, IL-6, IL-IO and tumour necrosis factor-alpha levels were also measured. No significant difference was observed in the sTREM-1 levels on the first three days between survivors and nonsurvivors. sTREM-1 levels moderately correlated with the Acute Physiology and Chronic Health Evaluation II and Sequential Organ Failure Assessment scores on day three, but did not correlate with vasopressor requirements, cytokine levels and the presence of bacteraemia. In contrast, procalcitonin levels were significantly higher in nonsurvivors than in survivors on days two and three. A significant relationship also existed between procalcitonin levels and the other variables. In conclusion, this study found that the prognostic utility of serum sTREM-1 in septic shock is poor and that procalcitonin measurements perform better in this regard.


Asunto(s)
Glicoproteínas de Membrana/sangre , Receptores Inmunológicos/sangre , Choque Séptico/sangre , Choque Séptico/diagnóstico , Biomarcadores/sangre , Calcitonina/sangre , Péptido Relacionado con Gen de Calcitonina , Citocinas/sangre , Femenino , Humanos , Immunoblotting/estadística & datos numéricos , Interleucinas/sangre , Masculino , Persona de Mediana Edad , Pronóstico , Precursores de Proteínas/sangre , Choque Séptico/mortalidad , Receptor Activador Expresado en Células Mieloides 1 , Factor de Necrosis Tumoral alfa/sangre
9.
Clin Chem Lab Med ; 43(7): 748-52, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16207137

RESUMEN

Methods for the measurement of autoantibodies frequently provide controversial results. The objective of the present study was to evaluate the performance of Spanish Clinical Laboratories in the measurement of anti-Sm antibodies. A total of 23 laboratories participated, analysing 30 serum samples from patients with systemic lupus erythematosus and other autoimmune and non-autoimmune diseases. The laboratories used four extractable nuclear antigen screens, eight enzyme-linked immunosorbent assays (ELISAs) specific for anti-Sm, one line-blot, one dot-blot and one double immunodiffusion assay, from 15 different manufacturers. A total of 871 results were obtained. In general, very good sensitivity was obtained (95-100%), but specificity was moderate (52-86%) and must be improved. Most ELISAs and the line-blot were valid assays for anti-Sm detection and could serve as tests both for analysis and/or confirmation. The likelihood ratios indicated that both methods can be considered very useful or useful for the determination of anti-Sm antibodies. Nevertheless, the analytical quality of the methods for the measurement of anti-Sm antibodies could probably be improved by standardisation of the methods and the participation of laboratories in external quality control programs.


Asunto(s)
Anticuerpos Antinucleares/sangre , Autoantígenos , Inmunoensayo/métodos , Ribonucleoproteínas Nucleares Pequeñas/inmunología , Adolescente , Adulto , Anciano , Especificidad de Anticuerpos , Ensayo de Inmunoadsorción Enzimática/métodos , Ensayo de Inmunoadsorción Enzimática/normas , Ensayo de Inmunoadsorción Enzimática/estadística & datos numéricos , Femenino , Humanos , Inmunoensayo/normas , Inmunoensayo/estadística & datos numéricos , Immunoblotting/métodos , Immunoblotting/normas , Immunoblotting/estadística & datos numéricos , Inmunodifusión/métodos , Inmunodifusión/normas , Inmunodifusión/estadística & datos numéricos , Laboratorios , Lupus Eritematoso Sistémico/diagnóstico , Lupus Eritematoso Sistémico/inmunología , Masculino , Persona de Mediana Edad , Control de Calidad , España , Proteínas Nucleares snRNP
11.
Appl Environ Microbiol ; 70(4): 2098-104, 2004 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15066801

RESUMEN

Immunoassays with specific antibodies offer higher sensitivity than do bioassays with indicator strains in the detection and quantification of several bacteriocins. Here we present the purification of lacticin RM and the production of specific polyclonal antibodies to a synthetic peptide resembling an internal fragment of the mature bacteriocin. The specificity and sensitivity of the generated polyclonal antibodies were evaluated in various immunoassays. The detection limits of lacticin RM were found to be 1.9, 0.16, and 0.18 micro g ml(-1) for Western blot, immuno-dot blot, and noncompetitive indirect enzyme-linked immunosorbent assays, respectively. Immunoassay sensitivities were 12.5-fold higher than that of the agar diffusion test (ADT). The production of lacticin RM showed temperature dependency, with 3, 4.2, 12.7, 28.9, 37.8, and 12 micro g ml(-1) at 37, 30, 20, 15, 10, and 4 degrees C, respectively. Temperature-stability analysis demonstrated that lacticin RM is sensitive to mild temperature, but the loss of activity does not seem to result from protein degradation. Tween 80 increased the concentration of lacticin RM eightfold and probably affected the results of the ADT either by enhancing the activity of lacticin RM or by increasing the sensitivity of the indicator strain. The use of antibodies for the specific detection and quantification of lacticin RM can expand our knowledge of its production and stability, with important implications for further investigation and future application.


Asunto(s)
Bacteriocinas/análisis , Secuencia de Aminoácidos , Animales , Anticuerpos Antibacterianos , Especificidad de Anticuerpos , Bacteriocinas/genética , Bacteriocinas/inmunología , Western Blotting/estadística & datos numéricos , Ensayo de Inmunoadsorción Enzimática/estadística & datos numéricos , Immunoblotting/estadística & datos numéricos , Lactococcus lactis/genética , Lactococcus lactis/inmunología , Datos de Secuencia Molecular , Polisorbatos , Conejos , Sensibilidad y Especificidad , Temperatura
12.
Immunol Invest ; 31(2): 93-106, 2002 May.
Artículo en Inglés | MEDLINE | ID: mdl-12148951

RESUMEN

We have previously demonstrated, using polyclonal and monoclonal antibodies, that the lactate dehydrogenase (LDH) of malaria parasites is immunologically distinct from the host enzyme. The polyclonal antibodies, produced against the affinity purified plasmodial LDH (pLDH) in rabbits, showed specificity to LDH of malaria parasites. In the present study, these anti-pLDH polyclonal antibodies were used to develop an immunodiagnostic test (immunodot enzyme assay of plasmodial LDH) based on the detection of parasite LDH in patient blood. The immunodot enzyme assay of plasmodial LDH was evaluated using blood samples from patients with malaria or other infections. Out of 502 microscopically positive malaria blood samples, 497 blood samples showed positive immunodot assays of pLDH while all the 423 microscopically negative cases were found negative by our test. The blood samples from other infections and non-endemic controls were negative by the immunodot enzyme assay of pLDH. This LDH based test was also found negative in blood samples of cured patients 7 days after chloroquine treatment. The test is simple to perform, can be read visually, econimal, highly specific with a sensitivity of approximately 99% and is thus suitable for accurate diagnosis of malaria in field conditions.


Asunto(s)
Immunoblotting/métodos , L-Lactato Deshidrogenasa/análisis , L-Lactato Deshidrogenasa/sangre , Malaria/diagnóstico , Malaria/enzimología , Plasmodium/enzimología , Animales , Anticuerpos Antiprotozoarios , Especificidad de Anticuerpos , Antimaláricos/uso terapéutico , Cloroquina/uso terapéutico , Humanos , Immunoblotting/estadística & datos numéricos , L-Lactato Deshidrogenasa/inmunología , Malaria/tratamiento farmacológico , Malaria/parasitología , Plasmodium/inmunología , Plasmodium knowlesi/enzimología , Plasmodium knowlesi/inmunología , Conejos , Sensibilidad y Especificidad
13.
Clin Diagn Lab Immunol ; 7(6): 867-71, 2000 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11063489

RESUMEN

The performance of six commercially available immunoassay systems for the detection of dengue virus-specific immunoglobulin M (IgM) and IgG antibodies in serum was evaluated. These included two IgM and IgG enzyme immunoassays (EIA) from MRL Laboratories and PanBio, a rapid immunochromatographic test (RIT) from PanBio, immunofluorescence assays (IFA) from Progen, a dot blot assay from Genelabs, and a dipstick EIA from Integrated Diagnostics (INDX). For this study a panel of 132 serum samples, including 90 serum samples from patients with suspected dengue virus infection and 42 serum samples from patients with other viral infections, was used. In addition, serial serum samples from two monkeys experimentally immunized and challenged with dengue virus type 2 were used. Results were considered conclusive when concordant results were obtained with four of the six antibody-specific assays. Based on this definition, the calculated overall agreement for the human serum samples for the respective IgM immunoassays was 97% (128 of 132), with 34% (45 of 132) positive serum samples, 63% (83 of 132) negative samples, and 3% of samples (4 of 132) showing discordant results. The calculated overall agreement for the IgG assays was 94% (124 of 132), with 49% (65 of 132) positive, 45% (59 of 132) negative, and 6% (8 of 132) discordant results, respectively. The sensitivities of the dengue virus-specific assays evaluated varied between 71 and 100% for IgM and between 52 and 100% for IgG, with specificities of 86 to 96% and 81 to 100%, respectively. The relative sensitivities of the respective IgM assays measured with the monkey serum samples were comparable with those obtained with 12 serial serum samples from humans. Overall performance, based on the sum of the agreement, sensitivity, specificity, and Kappa statistics of the IgM and IgG immunoassays, showed that the antibody detection systems from INDX and Genelabs and the MRL and PanBio EIA are useful and reliable assays for dengue virus serodiagnosis.


Asunto(s)
Anticuerpos Antivirales/sangre , Virus del Dengue/inmunología , Inmunoensayo/métodos , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Animales , Especificidad de Anticuerpos , Dengue/diagnóstico , Dengue/inmunología , Técnica del Anticuerpo Fluorescente/estadística & datos numéricos , Inmunización , Inmunoensayo/estadística & datos numéricos , Immunoblotting/métodos , Immunoblotting/estadística & datos numéricos , Técnicas para Inmunoenzimas/métodos , Técnicas para Inmunoenzimas/estadística & datos numéricos , Cinética , Macaca fascicularis , Sensibilidad y Especificidad , Pruebas Serológicas/métodos , Pruebas Serológicas/estadística & datos numéricos , Vacunas Virales/inmunología
14.
J Immunol Methods ; 237(1-2): 1-17, 2000 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-10725447

RESUMEN

Immune complexes are present in the circulation of healthy individuals and the formation of such complexes is part of a normal immune process. During some pathological conditions, significant amounts of immune complexes are formed and deposited in the kidney and other tissues, causing severe injury. Since the levels of immune complexes can provide valuable prognostic information, dozens of methods have been developed to detect and quantify these complexes. However, many of these methods are non-specific, not quantitative, and give false-positive results. Methods based on detecting the antigen portion of immune complexes can yield more precise information about circulating immune complexes. We have used a quantitative dot-blot assay, which permits detection of antigen even if buried, to determine the levels of antigen in circulating immune complexes. In healthy donors, significant amounts of immune complexes containing DNA and beta(2)-glycoprotein I were detected (natural immune complexes). Natural immune complexes with Lewis X antigen were also observed in the circulation of healthy persons. In experimentally induced murine systemic lupus erythematosus (SLE) and SLE patients, there was a correlation between the clinical manifestations and the levels of DNA in the circulating immune complexes. At severe SLE flares, the level of DNA in circulating immune complexes decreased, probably due to tissue deposition of immune complexes. The low levels of DNA in immune complexes circulating in SLE patients correlated with low serum concentrations of the complement component C1q. No direct correlation was found between the levels of circulating anti-dsDNA antibodies and DNA in immune complexes. Thus, quantitation of antigen levels in circulating immune complexes can be used to determine the prognosis of autoimmune diseases.


Asunto(s)
Complejo Antígeno-Anticuerpo/análisis , Antígenos/análisis , Immunoblotting/métodos , Adulto , Animales , Complejo Antígeno-Anticuerpo/sangre , Antígenos/sangre , Autoanticuerpos/análisis , Autoanticuerpos/sangre , Enfermedades Autoinmunes/inmunología , ADN/análisis , ADN/sangre , ADN/inmunología , Glicoproteínas/análisis , Glicoproteínas/sangre , Glicoproteínas/inmunología , Humanos , Inmunidad Innata , Immunoblotting/estadística & datos numéricos , Antígeno Lewis X/análisis , Antígeno Lewis X/sangre , Lupus Eritematoso Sistémico/inmunología , Ratones , Pronóstico , beta 2 Glicoproteína I
15.
J Vasc Surg ; 31(2): 325-42, 2000 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10664501

RESUMEN

PURPOSE: Matrix metalloproteinases (MMPs) are considered to play a central role in the pathogenesis of abdominal aortic aneurysms (AAAs). Doxycycline (Dox) has direct MMP-inhibiting properties in vitro, and it effectively suppresses the development of elastase-induced AAAs in rodents. The purpose of this study was to determine if treatment with Dox suppresses MMPs within human aneurysm tissue and to elucidate the molecular mechanisms underlying this effect. METHODS: Aneurysm tissues were obtained from 15 patients with an AAA, eight of whom had been treated with Dox before surgery (100 mg orally twice a day for 7 days). Protein extracts were examined by means of gelatin zymography and immunoblot analysis, and RNA was examined by means of reverse transcription-polymerase chain reaction (RT-PCR). The effects of Dox on MMP production were further examined in human THP-1 mononuclear phagocytes in vitro. RESULTS: No detectable difference was found between groups by using substrate zymography as a means of assessing total MMP activity, but Dox treatment was associated with a slight (24.4%) reduction in the activated fraction of 72-kDa gelatinase (MMP-2; P <.05). In contrast, a 2.5-fold reduction in the amount of extractable 92-kDa gelatinase (MMP-9) protein in Dox-treated patients was revealed by means of immunoblot analysis (P <.05). Also, a 5.5-fold (81.9%) reduction in MMP-9 messenger RNA (mRNA) in Dox-treated patients was demonstrated by means of quantitative competitive RT-PCR (mean +/- SE, mol MMP-9/mol beta-actin: 1.3 +/- 0.5 vs 7.2 +/- 3.1; P <.04). There was no significant difference between groups in the relative expression of MMP-2 protein or mRNA. In cultured THP-1 monocytes stimulated with phorbol ester, the expression of MMP-9 protein and mRNA were both decreased after exposure to relevant concentrations of Dox in vitro. CONCLUSION: In addition to its recognized effects as a direct MMP antagonist, Dox may influence connective tissue degradation within human aneurysm tissue by reducing monocyte/macrophage expression of MMP-9 mRNA and by suppressing the post-translational processing (activation) of proMMP-2. Through this complementary combination of mechanisms, treatment with Dox may be a particularly effective strategy for achieving MMP inhibition in patients with an AAA.


Asunto(s)
Antibacterianos/uso terapéutico , Profilaxis Antibiótica , Aorta/efectos de los fármacos , Aorta/enzimología , Aneurisma de la Aorta Abdominal/enzimología , Doxiciclina/uso terapéutico , Regulación Enzimológica de la Expresión Génica/efectos de los fármacos , Metaloproteinasas de la Matriz/genética , Anciano , Anciano de 80 o más Años , Antibacterianos/farmacología , Aorta/química , Aneurisma de la Aorta Abdominal/cirugía , Secuencia de Bases , Doxiciclina/farmacología , Femenino , Regulación Enzimológica de la Expresión Génica/fisiología , Humanos , Immunoblotting/métodos , Immunoblotting/estadística & datos numéricos , Masculino , Inhibidores de la Metaloproteinasa de la Matriz , Metaloproteinasas de la Matriz/análisis , Metaloproteinasas de la Matriz/efectos de los fármacos , Metaloproteinasas de la Matriz/metabolismo , Persona de Mediana Edad , Datos de Secuencia Molecular , Sondas de Oligonucleótidos , Procesamiento Proteico-Postraduccional/efectos de los fármacos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/estadística & datos numéricos
16.
Asian Pac J Allergy Immunol ; 18(1): 63-7, 2000 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-12546059

RESUMEN

We compared a noninvasive serological test using a commercial immunoblot assay (Helicoblot 2.0) to tissue-based methods [rapid urease test (CLO test), histology and culture] in eighty Thai patients undergoing upper endoscopy. A true positive test was defined as at least two of the biopsy-related tests being positive. The CLO test was the most accurate test with sensitivity and specificity as high as 100%, whereas histology and culture had sensitivity of 100% and 72.2%, respectively, and the specificity of 72.7% and 96%, respectively. The serological test had a high sensitivity (97.2%) but exhibited an unsatisfactory specificity (40.9%). We concluded that the rapid urease test using multiple gastric biopsies was the most appropriate method for diagnosing H. pylori status. The role of immunoblot assay as a serological screening test in our population remains doubtful, but it may identify patients who have been infected with certain strains of H. pylori.


Asunto(s)
Infecciones por Helicobacter/diagnóstico , Infecciones por Helicobacter/inmunología , Helicobacter pylori , Immunoblotting/métodos , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Antibacterianos/sangre , Biopsia , Femenino , Infecciones por Helicobacter/complicaciones , Infecciones por Helicobacter/enzimología , Helicobacter pylori/inmunología , Helicobacter pylori/aislamiento & purificación , Humanos , Immunoblotting/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Pruebas Serológicas , Úlcera Gástrica/complicaciones , Ureasa/análisis
17.
Vestn Ross Akad Med Nauk ; (8): 20-6, 1999.
Artículo en Ruso | MEDLINE | ID: mdl-10487119

RESUMEN

The comprehensive development of dot-EIA made at the State Research Institute of Biological Instrument-Making Industry has provided devices KIMF-02 and KIMF-03), a base of chemical reagents, immunoassays, test systems for detection of a wide range of causative agents of viral and bacterial infections, that of serodiagnosis of their related diseases. The KIMF-02 kit has undergone engineering and medical tests and recommended for the Ministry of Health of the Russian Federation to produce them in stock. The kit includes all required for analysis even in an ill-equipped laboratory, a set of attached agents ensures a valid visual recording of results. The developed procedures and test systems allow the immunoassay to be as sensitive as TIFA; however, they are laborious and much simpler in design. The simple and rapid procedures of dot-EIA are recommended for incorporation into the a package of laboratory methods for verification of the accumulation of virus-specific antigens in various biological substrata, environmental samples, for control of the activity of antigens and antibodies used in serological tests, for detection of specific antigens in the clinical samples, and for serodiagnosis of infections.


Asunto(s)
Infecciones Bacterianas/diagnóstico , Immunoblotting/métodos , Membranas Artificiales , Virosis/diagnóstico , Animales , Anticuerpos Antibacterianos/sangre , Anticuerpos Antivirales/sangre , Especificidad de Anticuerpos , Filtración/instrumentación , Filtración/métodos , Humanos , Immunoblotting/instrumentación , Immunoblotting/estadística & datos numéricos , Indicadores y Reactivos , Sensibilidad y Especificidad
18.
Rev Soc Bras Med Trop ; 32(2): 139-43, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10228363

RESUMEN

Dacron and nitrocellulose were evaluated as matrices for the dot enzyme linked immunosorbent assay (dot-ELISA) for schistosomiasis and compared to indirect immunofluorescence (IMF). Titration of sera from 18 schistosomiasis patients against soluble worm antigen preparation (SWAP) was carried out and sera from healthy individuals from non-endemic areas were used as controls. The IMF was less sensitive than the dot-ELISAs, although the difference was not statistically significant (p > 0.05). The dot-ELISA based on nitrocellulose was as sensitive as that using dacron. Stability did not differ between nitrocellulose and dacron. Specificity was lower when dacron was used than when nitrocellulose was used, although the difference was not statistically significant (p > 0.05). In conclusion, this work showed that nitrocellulose and dacron performed similarly in dot-ELISA, suggesting that they may be used alternatively in population surveillance in endemic areas.


Asunto(s)
Ensayo de Inmunoadsorción Enzimática/métodos , Immunoblotting/métodos , Esquistosomiasis mansoni/diagnóstico , Animales , Antígenos , Antígenos Helmínticos , Biomphalaria/inmunología , Colodión , Ensayo de Inmunoadsorción Enzimática/instrumentación , Ensayo de Inmunoadsorción Enzimática/estadística & datos numéricos , Técnica del Anticuerpo Fluorescente Indirecta/estadística & datos numéricos , Humanos , Immunoblotting/instrumentación , Immunoblotting/estadística & datos numéricos , Indicadores y Reactivos , Tereftalatos Polietilenos , Schistosoma mansoni/inmunología , Sensibilidad y Especificidad
19.
Indian J Exp Biol ; 37(2): 157-60, 1999 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10641136

RESUMEN

Bluetongue virus serotype 1 (Avikanagar isolate) was grown in BHK-21 cell line and titrated. The titre of the virus in BHK-21 cell line was 10(6) TCID50/ml. RNA-polyacrylamide gel electrophoresis (RNA-PAGE) and dot immunobinding assay (DIA) were performed on 10-fold serial dilutions of the sonicated cell culture material. The results indicated that the minimum limit of detection of the virus by RNA-PAGE and DIA was 10(5) TCID50/ml.


Asunto(s)
Virus de la Lengua Azul/aislamiento & purificación , Animales , Virus de la Lengua Azul/clasificación , Virus de la Lengua Azul/inmunología , Línea Celular , Cricetinae , Electroforesis en Gel de Poliacrilamida/métodos , Electroforesis en Gel de Poliacrilamida/estadística & datos numéricos , Immunoblotting/estadística & datos numéricos , ARN Viral/aislamiento & purificación , Sensibilidad y Especificidad
20.
Am J Trop Med Hyg ; 59(5): 757-62, 1998 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9840593

RESUMEN

A commercial IgM immunoblot kit was evaluated for dengue diagnosis with a panel of serum specimens collected from patients in a dengue endemic area. The kit is not recommended for use in its present form because of its undesirable rate of false-positive results. However, by substituting internal controls with the reference positive and negative controls that are more representative of those seen in endemic areas and by modifying the positive and negative scoring criteria, sensitivity and specificity of 80.3% and 94.5%, respectively, were obtained. These results are comparable with those obtained with the IgM ELISA on specimens, most of which were obtained from outpatient health care facilities. With further technical modifications, inclusion of a visual guide to ensure scoring standardization, and a more complete elaboration of the limitations of the test, wide application of the kit in diagnostic laboratories should be possible.


Asunto(s)
Anticuerpos Antivirales/sangre , Virus del Dengue/inmunología , Dengue/diagnóstico , Dengue/inmunología , Immunoblotting/métodos , Inmunoglobulina M/sangre , Pruebas Serológicas/métodos , Estudios de Casos y Controles , Reacciones Cruzadas , Ensayo de Inmunoadsorción Enzimática/métodos , Ensayo de Inmunoadsorción Enzimática/estadística & datos numéricos , Estudios de Evaluación como Asunto , Reacciones Falso Positivas , Flavivirus/inmunología , Pruebas de Inhibición de Hemaglutinación/métodos , Pruebas de Inhibición de Hemaglutinación/estadística & datos numéricos , Humanos , Immunoblotting/normas , Immunoblotting/estadística & datos numéricos , Estándares de Referencia , Sensibilidad y Especificidad , Pruebas Serológicas/normas , Pruebas Serológicas/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...