Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 704
Filtrar
1.
J Indian Prosthodont Soc ; 24(3): 300-305, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38946515

RESUMEN

BACKGROUND: The orchestration of jaw relations in edentulous scenarios poses a significant challenge, demanding acumen, and expertise from the clinician. A myriad of devices, substances, and methodologies are employed to gauge the transverse, vertical, and horizontal spectrums of jaw relations. Traditionally, a synthesis of assorted devices and techniques has been requisitioned to chronicle the spatial dynamics between the maxilla and mandible. Yet, the absence of a solitary apparatus capable of concurrently documenting the triad of jaw relations has been a notable lacuna in prosthodontic rehabilitation. PURPOSE: This discourse expounds on an innovative contrivance, termed the Precise Jaw Relation Recorder. This pioneering instrument is adept at capturing the tripartite jaw relation processes: the occlusal plane's alignment in parallelism to the ala-tragus line, the vertical dimension at repose, and the occlusion as well as the centric relation. The device's strategic utility lies in its ability to facilitate the creation of prostheses that are not only functionally superior but also aesthetically more pleasing. CONCLUSION: Its implementation is a stride toward refining the accuracy of prosthodontic outcomes, thereby elevating the standard of patient care in dental practice.


Asunto(s)
Prostodoncia , Humanos , Registro de la Relación Maxilomandibular/instrumentación , Registro de la Relación Maxilomandibular/métodos , Prostodoncia/métodos , Prostodoncia/instrumentación , Oclusión Dental
2.
J Oral Rehabil ; 51(9): 1675-1683, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38926933

RESUMEN

BACKGROUND: The T-scan system has been used previously to analyse occlusion, but the quantitative analysis of occlusal contact by T-Scan system has yet to be reported. OBJECTIVES: To evaluate the reliability and validity of T-Scan system for quantitatively measuring occlusal contact area and occlusal contact number. METHODS: Twenty-two individuals with normal occlusion, 11 men and 11 women, were recruited for the study. Two occlusal analysis methods, including silicone transmission analysis method (STA) and T-Scan occlusion analysis method (TSO), were used to make quantitative analysis to measure occlusal contact area (OCA) and occlusal contact number (OCN). A test-retest check was performed with an interval of 2 weeks. The values of intraclass correlation coefficients (ICC) between test-retest of each method were calculated for reliability evaluation. Pearson correlations analysis, paired t-tests, regression analysis and Bland-Altman analysis were performed for validity evaluation. RESULTS: The ICC values of STA were greater than those of TSO for OCA while for OCN, ICC values of TSO were greater than STA. The higher OCA and OCN values were found in TSO compared with STA. Pearson's correlation coefficient indicated strong relations between TSO and STA (0.730-0.812) for OCA, while good relations between then (0.569-0.583) for OCN. Paired t-test showed a significant difference between the OCA and OCN values between TSO and STA. Bland-Altman analysis showed good agreement between OCA and OCN values of TSO and STA both in men and women. Regression analysis identified a linear correlation between OCA values obtained from these two methods. CONCLUSIONS: T-Scan method showed strong reliability for measuring OCA and OCN quantitatively. Strong correlations were found between OCA values from TSO and STA method, but the validity of TSO for measuring OCN needs to be promoted. CLINICAL SIGNIFICANCE: T-Scan system demonstrates good potential in quantitative analysis of occlusion, which will expand its clinical application.


Asunto(s)
Oclusión Dental , Humanos , Femenino , Masculino , Reproducibilidad de los Resultados , Adulto , Adulto Joven , Registro de la Relación Maxilomandibular/métodos , Registro de la Relación Maxilomandibular/instrumentación
3.
J Oral Rehabil ; 51(9): 1662-1674, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38943246

RESUMEN

BACKGROUND: Occlusal contacts can be stained and thereby visualised employing occlusal indicators. Qualitative and quantitative indicators are differentiated. The hybrid system OccluSense supposedly combines analogue contact marking and digital registration of contacts. The reliability and validity of its contact marking have not yet been validated. OBJECTIVES: The aim of this controlled randomised in-vitro study was to examine the reliability and validity of analogue contact staining with OccluSense compared to Arti-Fol and the reference standard Gnatho-Film. MATERIALS AND METHODS: An experimental apparatus was designed to simulate static occlusion. The occlusal contacts were stained 50 times with Gnatho-Film to determine the average number and location of contacts registered. For comparison, the contacts were pre-stained with Gnatho-Film and then registered with Arti-Fol or OccluSense 50 times each. Every staining was statistically evaluated and compared to Gnatho-Film alone, regarding the number and location of contacts. Based on the observed characteristic staining behaviour of OccluSense, a modified evaluation strategy was developed for its colour markings (OccluSense (mod.)). RESULTS: Both evaluations of OccluSense determine that the same number of contacts was registered in over 94% of all cases. Neither OccluSense nor Arti-Fol stain the exact same number of contacts as Gnatho-Film, but the modified evaluation OccluSense (mod.) did improve the results for validity. CONCLUSION: When employing the modified evaluation strategy, OccluSense staining achieves similar reliability and validity as the reference standard. Pre-colouring of occlusal contacts with Gnatho-Film and the modified evaluation strategy, might become standard for analysing occlusal contacts stained by OccluSense in the future.


Asunto(s)
Oclusión Dental , Reproducibilidad de los Resultados , Humanos , Registro de la Relación Maxilomandibular/instrumentación , Registro de la Relación Maxilomandibular/métodos , Técnicas In Vitro
4.
Clin Oral Investig ; 28(6): 320, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38750145

RESUMEN

OBJECTIVES: The purpose of this scoping review was to identify different methods employed for recording the maxillomandibular relationship (MMR) for computer-aided designed and manufactured (CAD-CAM) complete dentures (CDs). MATERIALS AND METHODS: This scoping review followed the PRISMA-ScR guidelines and was developed according to Arksey and O'Malley and The Joanna Briggs Institute protocol. The methods were registered on the Open Science Framework (< osf.io/rf4xm> ). The focus question was: "What are the different techniques for recording the maxillomandibular relationship in the digital workflow used in CECDs?" Two investigators searched 3 online databases [MEDLINE (PubMed), Scopus, and Science Direct] independently. The inclusion criteria were clinical studies and reviews that assessed techniques for recording MMR using digital workflow for manufacturing of CECDs. A descriptive analysis was performed considering the study design, manufacturing system, clinical steps, and tools for the determination of MMR, and the difficulty level of procedures. RESULTS: 4779 articles were identified in the electronic search and 10 studies were included for data analysis. The review identified 4 commercially available CAD-CAM denture systems and 3 innovative methods suitable for abbreviating the number of appointments (2 to 4 visits). The trial denture is inherent to the procedure for the Baltic System and 3 innovative techniques. Three techniques (2 innovative and WholeYouNexteeth) demonstrated lower difficulty levels for performing the clinical procedures, regardless of the professional skills. CONCLUSIONS: The commercially available and innovative techniques for the recording of MMR may provide predictability of the treatment. The techniques are effective, however, rely on the learning curve and the patient's clinical condition. CLINICAL RELEVANCE: Recording of the maxillomandibular relationship is paramount for the manufacturing and functionality of complete dentures. Clinicians should be aware of the different tools and techniques described for registering the jaw relationship.


Asunto(s)
Diseño Asistido por Computadora , Diseño de Dentadura , Dentadura Completa , Humanos , Diseño de Dentadura/métodos , Registro de la Relación Maxilomandibular/métodos
5.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 42(1): 67-74, 2024 Feb 01.
Artículo en Inglés, Chino | MEDLINE | ID: mdl-38475953

RESUMEN

OBJECTIVES: This clinical study aimed to evaluate the accuracy of a fully digital technique for measuring sagittal condylar inclination (SCI), as well as validating whether differences existed between the left and right SCI values of the same participant, to provide a reference for clinical practice. METHODS: Ten participants with good occlusal relationship and normal temporomandibular joint were recruited. Three methods were used to measure the SCI values of the participants, namely, A (mechanical facebow transferring and mechanical articulator-based measuring method with physical protrusive interocclusal registration), B (face scan-based virtual facebow and virtual articulator-based measuring method with digital protrusive interocclusal registration), and C (jaw motion tracking system-based measuring method). With the group subjected to methods A and C as the control, the SCI values obtained by the three methods were statistically analyzed. The left and right SCI values of the same participant were also compared. RESULTS: The left and right SCI values measured by method A were 41.70°±7.09° and 42.80°±8.62°, those by method B were 35.09°±12.49° and 37.63°±12.10°, and those by method C were 39.43°±8.72° and 38.45°±6.91°. No significant difference existed among the SCI values measured by the three methods (P>0.05). Meanwhile, no statistical difference existed between the SCI values on the left and right sides of the same participant (P>0.05). CONCLUSIONS: The accuracy of the virtual facebow and digital protrusive occlusal registration based SCI measuring method was the same as that of mechanical facebow based and jaw motion tracking system-based methods. The SCI values on the left and right sides of the same participant were similar. Clinically, an appropriate SCI measurement and setting strategy can be selected based on the actual situations.


Asunto(s)
Cóndilo Mandibular , Articulación Temporomandibular , Humanos , Registro de la Relación Maxilomandibular/métodos , Articuladores Dentales , Aparatos de Tracción Extraoral
6.
Clin Oral Investig ; 28(4): 233, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38556612

RESUMEN

OBJECTIVES: Reconstruction of a three-dimensional jaw position determined by a bite recording is an important aspect of prosthetic therapy. Different materials are used for this purpose. In the dental technical workflow, recordings are used to mount a lower jaw cast in a patient-like spatial position relative to the upper jaw cast. We evaluated the accuracy of positioning under the influence of different jaw positions and materials. MATERIALS AND METHODS: In an experimental setup, comprising an articulator, a pair of metal casts, and an optoelectronic measurement system, the spatial position of the incisal point and two condylar points were measured. To evaluate the accuracy of repeated repositioning of casts in the technical workflow, 324 measurements were taken from 108 recordings, consisting of silicone bite-stops made of addition curing silicone with 95 shore hardness, acrylic wafers, and wax recordings. The recordings were obtained in four jaw relations differing in vertical and protrusive components. RESULTS: Of the three materials/material combinations examined, silicone showed the most consistent results across all measurements, followed by the acrylic wafer system, and then wax recordings. Generally, recordings with smaller gaps between the jaws and no protrusive components showed greater deviations compared to jaw positions with greater protrusion and higher vertical dimensions. CONCLUSIONS AND CLINICAL RELEVANCE: To achieve reliable model mounting with high accuracy, recordings should include the use of a frontal jig and four small recording platelets made of silicone, especially if only a slight elevation of the vertical dimension is needed.


Asunto(s)
Articuladores Dentales , Mandíbula , Humanos , Registro de la Relación Maxilomandibular/métodos , Dimensión Vertical , Siliconas
7.
J Esthet Restor Dent ; 36(5): 710-722, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38131436

RESUMEN

OBJECTIVE: The purpose of this article was to introduce a method for the digital application of three-dimensional (3D) diagnosis and treatment with a virtual articulator and 3D data. CLINICAL CONSIDERATION: With the use of cone-beam computed tomography (CBCT) and intraoral and facial scans, we can create a virtual articulator and evaluate the mandibular position in maximum intercuspation and centric-related occlusion for the patient with an unstable occlusion and temporomandibular disorders (TMD). Based on this, we treated a case using a digital mandibular position indicator (MPI) and fabricated a stabilization splint using a 3D printer. This approach eliminates the traditional impression or model mounting process and the analog face bow transfer. Furthermore, the design of the stabilization splint is accomplished using software. CONCLUSIONS: The approach outlined in this article offers the potential for a digital diagnosis and treatment process by seamlessly integrating CBCT, intraoral scans, and facial scans with a high degree of accuracy. This may enhance precision in diagnosis and treatment planning, especially for patients with complicated TMD, in addition to facilitating effective communication with orthodontic patients who require thorough attention. CLINICAL SIGNIFICANCE: Utilizing a virtual articulator and digital MPI for the occlusal evaluation of patients with TMD and unstable occlusion makes it possible to diagnose and analyze the occlusal condition accurately. This approach also allows for precision and efficiency in treatment.


Asunto(s)
Articuladores Dentales , Imagenología Tridimensional , Humanos , Registro de la Relación Maxilomandibular/métodos , Imagenología Tridimensional/métodos , Modelos Dentales , Oclusión Dental , Tomografía Computarizada de Haz Cónico/métodos
8.
J Indian Prosthodont Soc ; 23(4): 322-334, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37861609

RESUMEN

Aim: The aim of this systematic review and meta-analysis was to determine the accuracy of different methods of measuring horizontal condylar guidance (HCG) angle in comparison with extraoral Gothic arch tracing for completely edentulous patients. Settings and Design: This was a systematic review and meta-analysis following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Materials and Methods: Two reviewers searched the EBSCOhost, Cochrane Library, and PubMed/MEDLINE databases and the Google Scholar search engine for in vivo studies, randomized controlled trials, cross-sectional studies, and quasi-experimental studies published from January 2005 to December 2022 on various other methods of determining HCG angle in completely edentulous patients compared with extraoral Gothic arch tracing method. Statistical Analysis Used: Meta-analysis was conducted from the reported quantitative data. Results: A total of 513 articles were obtained from different electronic databases, of which 22 studies were included for qualitative synthesis and 20 studies were included for meta-analysis. For the right side, a statistically significant difference was observed for panoramic radiograph (P < 0.05, pooled mean difference = 5.08 [2.17, 7]) and cephalogram (P < 0.05, pooled mean difference = 10.65 [8.81, 12.49]), whereas no statistically significant difference was observed for cone-beam computed tomography (CBCT) (P = 0.41, pooled mean difference = 4.39 [-6.10, 14.87]) and protrusive interocclusal wax record (P = 0.92, pooled mean difference = -0.45 [-9.62, 8.72]) as compared with extraoral Gothic arch tracing method. For the left side, a statistically significant difference was observed for panoramic radiograph (P < 0.05, pooled mean difference = 5.07 [1.95, 8.18]) and cephalogram (P < 0.05, pooled mean difference = 10.24 [8.65, 11.83]), whereas no statistically significant difference was observed for CBCT (P = 0.31, pooled mean difference = 4.05 [-3.74, 11.84]) and protrusive interocclusal wax record (P = 0.72, pooled mean difference = -1.21 [-7.86, 5.43]) as compared with extraoral Gothic arch tracing method. Conclusion: The cephalogram and panoramic radiograph obtained higher HCG angles in completely edentulous patients than extraoral Gothic arch tracing.


Asunto(s)
Boca Edéntula , Humanos , Registro de la Relación Maxilomandibular/métodos , Estudios Transversales , Boca Edéntula/diagnóstico por imagen , Radiografía Panorámica , Tomografía Computarizada de Haz Cónico
9.
J Contemp Dent Pract ; 24(6): 403-408, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37534507

RESUMEN

AIMS: A clinical study to compare the horizontal condylar guidance using protrusive interocclusal records, orthopantomography (OPG), and cone-beam computed tomography (CBCT) in edentulous patients. SUBJECTS AND METHODS: Thirty-six edentulous subjects were selected as per predetermined criteria. Horizontal condylar guidance was recorded using protrusive interocclusal records (PIR), OPG, and CBCT for each patient. The PIR were obtained using extraoral Gothic arch tracers to program the Hanau articulator. The horizontal condylar guidance angles (HCGAs) were digitally constructed using appropriate software along the posterior slope of articular eminence for all radiographs. The collected data were recorded, tabulated, and statistically analyzed. RESULTS: The condylar guidance angle values were tested for significance to compare the different angles. The correlation of HCGA measurements on both sides between the three groups was analyzed. The PIR and OPG methods (p = 0.001), as well as the OPG and CBCT methods (p = 0.001), show substantial differences on both sides. On the contrary, the PIR and CBCT methods did not differ significantly (p = 0.11). CONCLUSION: Cone-beam computed tomography is as reliable and accurate as the clinical method. A significant correlation exists between the clinical method and CBCT. It can be used as a dependable adjunct to the clinical method of HCGA measurement. CLINICAL SIGNIFICANCE: Cone-beam computed tomography can overcome the shortcomings of the conventional clinical methods to determine the accurate horizontal condylar guidance angulation measurement. It is safer with minimum discomfort and wastage of time for the patients.


Asunto(s)
Boca Edéntula , Tomografía Computarizada de Haz Cónico Espiral , Humanos , Radiografía Panorámica , Registro de la Relación Maxilomandibular/métodos , Cóndilo Mandibular/diagnóstico por imagen , Boca Edéntula/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico
10.
J Dent ; 135: 104583, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37331577

RESUMEN

OBJECTIVES: The aim of this study was to clinically evaluate the accuracy of a digital axiographic recording system in tracing the sagittal condylar inclination. METHODS: An axiographic examination that records the sagittal condylar path during protrusive/retrusive movement was performed on ten patients. Each subject was registered five different times by two different systems: 1) the Cadiax Gamma Diagnostic 4 computerized system as the control; 2) the Zebris Jaw Motion Analyser+  Optic System as the tested digital axiographic recording system. The records obtained allow to calculate the kinematic terminal transverse horizontal axis and the sagittal condylar inclination (SCI) at 3 and 5 mm along the pro-retrusive path. A linear mixed model was used to analyze if there was a statistically significant difference between the two systems. RESULTS: The mean left SCI value recorded by Zebris system were 49.81 ± 10.64° at 3 mm, 48.10 ± 11.04° at 5 mm, while the values recorded by Gamma system were 55.16° at 3 mm, 52.18° at 5 mm. The mean right SCI value recorded by Zebris system were 54.53 ± 10.26° at 3 mm, 51.85 ± 8.55° at 5 mm, while the values recorded by Gamma system were 49.68° at 3 mm, 48.23° at 5 mm. Linear mixed model showed no significant statistical difference between the two systems. CONCLUSIONS: Based on preliminary results, the Zebris Jaw Motion Analyzer+ Optic System demonstrates comparable accuracy to the Cadiax Gamma Diagnostic 4 when measuring sagittal condylar inclination. CLINICAL SIGNIFICANCE: The digital axiographic recording system enables to evaluate sagittal condylar inclination and to adjust virtual articulators in a digital workflow.


Asunto(s)
Cóndilo Mandibular , Movimiento , Humanos , Cóndilo Mandibular/diagnóstico por imagen , Registro de la Relación Maxilomandibular/métodos , Articuladores Dentales , Fenómenos Biomecánicos
11.
J Esthet Restor Dent ; 35(7): 1068-1076, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37132534

RESUMEN

OBJECTIVE: This technique aimed to describe a fully digital workflow to register maxillomandibular relation for fixed prosthetic rehabilitation. CLINICAL CONSIDERATIONS: Mandibular kinematics could be reproduced in a four-dimensional (4D) virtual patient based on the intraoral scan, facial scan, cone beam computed tomography, and jaw motion trajectory, which helped record centric relation and determine a proper occlusal vertical dimension in a virtual environment. The therapeutic position could be exported directly to the dental computer-aided design software for digital waxing design with a facial scan. The 4D virtual patient was also used to verify the functional and esthetic outcomes of provisional restorations. CONCLUSIONS: This novel approach digitized the process of determination, delivery, and double-check of maxillomandibular relation, thus contributing to the establishment of a completely digital workflow for fixed prosthetic rehabilitation. CLINICAL SIGNIFICANCE: Registration of maxillomandibular relation, including centric relation and occlusal vertical dimension is critical to the success of prosthetic rehabilitation. Traditional procedures are complex and time-consuming, and heavily rely on the clinical experience of dentists. A fully digital approach to creating a 4D virtual patient and registering the maxillomandibular relation is established, which guides to determine a proper occlusal vertical dimension in centric relation. Digital delivery and double-check can simplify the conventional procedure and ensure that the determined maxillomandibular relation is reliable.


Asunto(s)
Diseño Asistido por Computadora , Mandíbula , Humanos , Flujo de Trabajo , Dimensión Vertical , Registro de la Relación Maxilomandibular/métodos
12.
Clin Oral Investig ; 27(7): 4017-4028, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37247089

RESUMEN

OBJECTIVES: This clinical study aimed to compare the performance of various virtual articulator (VA) mounting procedures in the participants' natural head position (NHP). MATERIALS AND METHODS: Fourteen participants with acceptable dentitions and jaw relationships were recruited in this study registered in the Clinical Trials Registry (#NCT05512455; August 2022). A virtual facebow was designed for virtual mounting and hinge axis measurement. Intraoral scans were obtained, and landmarks were placed on each participant's face to register the horizontal plane in NHP. Six virtual mounting procedures were performed for each participant. The average facebow group (AFG) used an indirect digital procedure by using the average facebow record. The average mounting group (AMG) aligned virtual arch models to VA's average occlusal plane. The smartphone facial scan group (SFG) and professional facial scan group (PFG) used facial scan images with Beyron points and horizontal landmarks, respectively. The cone-beam computed tomography (CBCT) scan group (CTG) used the condyle medial pole, and horizontal landmarks were applied. The kinematic facebow group (KFG) served as the control group, and a direct digital procedure was applied using a kinematic digital facebow and the 3D skull model. Deviations of the reference plane and the hinge axis between the KFG and other groups were calculated. The inter-observer variability in virtual mounting software operation was then evaluated using the interclass correlation coefficient (ICC) test. RESULTS: In virtual condylar center deviations, the CTG had the lowest condylar deviations. The AFG showed larger condylar deviations than PFG, SFG, and CTG. There was no statistically significant difference between the AFG and the AMG and between the PFG and the SFG. In reference plane deviations, the AMG showed the largest angular deviation (8.23 ± 3.29°), and the AFG was 3.89 ± 2.25°. The angular deviations of PFG, SFG, and CTG were very small (means of each group < 1.00°), and there was no significant difference among them. There was no significant difference between the researchers, and the ICC test showed moderate to excellent reliability for the virtual condylar center and good to excellent reliability for the reference plane in the operation of the virtual mounting software. CONCLUSIONS: CBCT scan provided the lowest hinge axis deviation in virtual mounting compared to average mounting, facebow record, and facial scans. The performance of the smartphone facial scanner in virtual mounting was similar to that of the professional facial scanner. Direct virtual mounting procedures using horizontal landmarks in NHP accurately recorded the horizontal plane. CLINICAL RELEVANCE: Direct digital procedures can be reliably used for virtual articulator mounting. The use of a smartphone facial scanner provides a suitable and radiation-free option for clinicians.


Asunto(s)
Articuladores Dentales , Oclusión Dental , Humanos , Registro de la Relación Maxilomandibular/métodos , Maxilar , Reproducibilidad de los Resultados
13.
J Oral Rehabil ; 50(7): 617-626, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36943389

RESUMEN

BACKGROUND: Evaluating occlusal contacts during maximum intercuspation is one of the requirements for guiding clinicians during occlusal corrections and has been a topic of considerable importance for researchers over many decades. OBJECTIVE: This systematised review intends to evaluate the average number of occlusal contacts present in dentate adults, as documented within the dental literature over the past four decades (1980s-2022). METHODOLOGY: Electronic searches were conducted in three databases (PubMed, Livivo and Ovid) using a combination of search words. RESULTS: A total of 651 records were identified through PubMed and another 37 records through Livivo and Ovid databases. After eliminating duplicates and irrelevant records, 168 records were screened. Full texts of 61 articles remained, out of which 18 relevant papers that presented occlusal contacts in quantifiable value were considered. Various occlusal indicators, such as articulating paper, wax sheets, shimstock foil, impression material, gnathodynamometers and digital occlusal analysis systems, were used to evaluate occlusal contacts. The number of occlusal contacts widely ranged from 11 to 70. These variations likely depends upon the type and technique of occlusal indicator used, diversity among sampled populations and differing data collection procedures. CONCLUSION: Different methods of identifying occlusal contacts in the intercuspal position yield different numbers and patterns of contacts, depending on the nature and physical properties of the indicators used.


Asunto(s)
Materiales de Impresión Dental , Oclusión Dental , Humanos , Adulto , Registro de la Relación Maxilomandibular/métodos , Mandíbula
14.
Beijing Da Xue Xue Bao Yi Xue Ban ; 55(1): 101-107, 2023 Feb 18.
Artículo en Chino | MEDLINE | ID: mdl-36718696

RESUMEN

OBJECTIVE: To verify the consistency between the digital manufacturing simple intraoral Gothic arch-tracing device and the traditional intraoral Gothic arch-tracing device in determining the centric relation of complete dentures restoration. METHODS: Ten outpatients with edentulous jaws were selec-ted, and the centric relation of the patients was determined by digital manufacturing of simple intraoral Gothic arch-tracing device (T1) and traditional intraoral Gothic arch-tracing device (T2); the difference of clinical operation time between the two methods was recorded; the upper and lower edentulous jaw plaster models were scanned with two kinds of centric relation, the Standard Triangle Language (STL) files imported into Geomagic studio software to apply the best fitting of multiple points of the both upper jaw models, the fitted STL files imported into the 3 shape viewer software, and the maximum position deviations of the vertical, labial (buccal) and lingual directions of the mandibular midline area and molar areas in T1 and T2 groups measured. During the clinical complete dentures try-in, we observed whether there was midline deviation in the mouth of T1 group and T2 group, and whether the occlusion of posterior teeth was stable or not. RESULTS: The mean time spent on determining the centric relation of T1 and T2 groups was (41.90±2.64) min, (57.50±2.37) min respectively. Paired t test was conducted in the two groups, P < 0.01 with significant statistical difference; The mean maximum position deviation between T1 group and T2 group of the midline mandibular region in labial lingual direction was (0.32±0.14) mm, that was (0.40±0.23) mm in vertical direction; the mean maximum position deviation of molar area in buccal lingual direction was (0.35±0.23) mm and that was (0.33±0.20) mm in vertical direction. In the vertical and horizontal directions, the maximum position deviation of mandibles between group T1 and group T2 was controlled within 0.5 mm. In the process of clinical complete dentures try-in, there was no deviation from the center line of dentures. There was not warping, swinging and other poor stability phenomena in T1 and T2 groups. CONCLUSION: The digital manufacturing of simple intraoral Gothic arch-tracing device can be used to determine the centric relation of complete dentures, which can not only save time of clinical operation, but also ensure the accuracy of the centric relation.


Asunto(s)
Arcada Edéntula , Boca Edéntula , Humanos , Relación Céntrica , Registro de la Relación Maxilomandibular/métodos , Dentadura Completa
15.
J Indian Prosthodont Soc ; 23(1): 65-70, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36588377

RESUMEN

Aim: The fabrication of an accurate prosthesis depends mainly on precise recording of the maxillo-mandibular relationship of the patient and transferring it to the articulator. BDIMPRESS is a new thermoplastic material that has been proposed as a potential material to be used as an inter-occlusal registration, but there has been no literature evidence regarding its application as a bite registration. The main purpose of this study is to evaluate and compare the dimensional stability, detail reproduction, and compressive resistance of new interocclusal recording material with other two commonly used materials. Settings and Design: In Vitro Comparative study. Materials and Methods: The study was conducted according to ADA Specification standards of testing for dimensional stability, detail reproduction and compressive resistance. Specimens were prepared for three different materials (Thermoplastic resin, Polyvinyl siloxane, and Bis- acrylic) with 12 samples each. Statistical Analysis Used: One way ANOVA was done for statistical analysis. Results: Polyvinyl siloxane material was dimensionally stable (mean at 1 hr: 24.928 mm; 24 hrs: 24.919 mm & 48 hrs: 24.912 mm) followed by Bis- acrylic material (mean at 1 hr: 24.851 mm; 24 hrs: 24.825 mm & 48 hrs: 24.815 mm). On one way ANOVA, strong significance was observed between groups (P = 0.00). Thermoplastic resin showed higher amount of detail reproduction with 10 (out of 12 samples) samples showing satisfactory results. While bis- acrylic material showed the least compressive resistance (Strain %: 0.484%; Displacement- 0.0990mm). One-way ANOVA showed presence of significance between the groups (P = 0.024). Conclusion: Polyvinyl siloxane showed superior dimensional stability, thermoplastic resin showed better detail reproduction and bis- acrylic showed high resistance to compression over other materials.


Asunto(s)
Polivinilos , Siloxanos , Humanos , Registro de la Relación Maxilomandibular/métodos , Resinas de Plantas , Polimetil Metacrilato
16.
J Prosthet Dent ; 130(3): 288-294, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34887077

RESUMEN

This technique report presents a novel method of digitally replicating a treatment denture and converting it into a definitive denture. The procedure accurately duplicates the appearance of the mucosal surface and border of the treatment dentures, mounts the jaw relation on a virtual articulator to arrange artificial teeth, and optimizes the occlusion based on recorded mandibular motion tracks. This technique uses personalized jaw relation transfer and dynamic occlusal adjustment to establish balanced occlusion, which accomplishes the digital duplication of the treatment denture with high accuracy and minimal effort.


Asunto(s)
Dentadura Completa , Ajuste Oclusal , Flujo de Trabajo , Diseño de Dentadura/métodos , Oclusión Dental , Articuladores Dentales , Registro de la Relación Maxilomandibular/métodos
17.
J Prosthodont ; 32(6): 482-488, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36074517

RESUMEN

PURPOSE: Centric relation (CR) is a universally recognized term and an acceptable reference position with a long history of success. The problem is that there is little consensus as to its definition or the method of recording it, and this has created an uprising to abolish it. METHODS: A review of pertinent literature related to its definition, method of recording, anatomic considerations, and long-standing principles was conducted. RESULTS: Centric relation is an established term but there are valid concerns over its definition and method of recording. There is consensus on using it as a restorative position in a patient in need of full-arch reconstruction, and there is no substantive clinical research to contradict this. If a clinician decides to use a different position, it should have a different name. CONCLUSIONS: Centric relation is a reproducible reference position that can be utilized for diagnostic and restorative dental procedures with substantial scientific evidence to support that premise. There are numerous well-documented techniques, all of which are intermaxillary, that can replicate the position. There is little scientific evidence to support a premise as to where the exact position of the condyle should be in relation to the fossa.


Asunto(s)
Oclusión Dental Céntrica , Cóndilo Mandibular , Humanos , Relación Céntrica , Consenso , Registro de la Relación Maxilomandibular/métodos
18.
J Prosthodont ; 32(6): 497-504, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36573906

RESUMEN

PURPOSE: To assess the reproducibility of four different centric relation (CR) recording techniques, and time spent performing each technique in edentulous individuals. MATERIALS AND METHODS: Four techniques were assessed: extraoral gothic arch (EOGA) tracing, intraoral gothic arch (IOGA) tracing, deglutition (D), and frontal manipulation with tongue elevation (FMTE). Twelve subjects participated in the study; four technique records were performed on each volunteer by the same operator. Each record was repeated three times, in the same period of the day, with a 30 min interval between each technique. The reproducibility of each technique was assessed by the tri-dimensional displacement of the position of the condylar housing (mandible condyle) to the wall of the condylar guide (glenoid cavity) in the semi-adjustable articulator (anteroposterior, mediolateral, and superior-inferior). The time spent on each technique was timed in seconds (from the beginning of each technique until the wax occlusion fixation). The analysis of variance (ANOVA) and the Tukey test were performed for anteroposterior displacement (two-way) and for time spent on CT recording techniques (one-way) (α < 0.05). Regarding mediolateral and superior-inferior displacements, the nonparametric Kruskal-Wallis was performed for the comparison between recording methods, whereas the Mann-Whitney test was performed for the comparison between sides (α < 0.05). RESULTS: The factor recording technique interfered with the anteroposterior displacement (ANOVA: α < 0.001; F = 11.396). The technique D (right side: 3.78 ± 0.69 mm; left side: 3.45 ± 0.74 mm) showed a statistically significant difference compared to the other techniques (EOGA: right side: 3.00 ± 0.00 mm; left side: 3.00 ± 0.00 mm; FMTE: right side: 2.81 ± 0.52 mm; left side: 2.82 ± 0.79 mm; IOGA: right side: 2.90 ± 0.65 mm; left side: 3.12 ± 0.44 mm). The time spent on the recording technique influenced the results (ANOVA: α < 0.001; F = 21.118). The IOGA (340.40 ± 163.41 s) and EOGA (285.93 ± 133.84 s) required more time compared to the D (86.00 ± 34.33 s) and FMTE (101.33 ± 36.72 s) techniques. CONCLUSION: Graphic recordings showed better reproducibility and accuracy of the position of the centric relation.


Asunto(s)
Boca Edéntula , Humanos , Relación Céntrica , Registro de la Relación Maxilomandibular/métodos , Reproducibilidad de los Resultados , Estudios Transversales , Cóndilo Mandibular
19.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-971280

RESUMEN

OBJECTIVE@#To verify the consistency between the digital manufacturing simple intraoral Gothic arch-tracing device and the traditional intraoral Gothic arch-tracing device in determining the centric relation of complete dentures restoration.@*METHODS@#Ten outpatients with edentulous jaws were selec-ted, and the centric relation of the patients was determined by digital manufacturing of simple intraoral Gothic arch-tracing device (T1) and traditional intraoral Gothic arch-tracing device (T2); the difference of clinical operation time between the two methods was recorded; the upper and lower edentulous jaw plaster models were scanned with two kinds of centric relation, the Standard Triangle Language (STL) files imported into Geomagic studio software to apply the best fitting of multiple points of the both upper jaw models, the fitted STL files imported into the 3 shape viewer software, and the maximum position deviations of the vertical, labial (buccal) and lingual directions of the mandibular midline area and molar areas in T1 and T2 groups measured. During the clinical complete dentures try-in, we observed whether there was midline deviation in the mouth of T1 group and T2 group, and whether the occlusion of posterior teeth was stable or not.@*RESULTS@#The mean time spent on determining the centric relation of T1 and T2 groups was (41.90±2.64) min, (57.50±2.37) min respectively. Paired t test was conducted in the two groups, P < 0.01 with significant statistical difference; The mean maximum position deviation between T1 group and T2 group of the midline mandibular region in labial lingual direction was (0.32±0.14) mm, that was (0.40±0.23) mm in vertical direction; the mean maximum position deviation of molar area in buccal lingual direction was (0.35±0.23) mm and that was (0.33±0.20) mm in vertical direction. In the vertical and horizontal directions, the maximum position deviation of mandibles between group T1 and group T2 was controlled within 0.5 mm. In the process of clinical complete dentures try-in, there was no deviation from the center line of dentures. There was not warping, swinging and other poor stability phenomena in T1 and T2 groups.@*CONCLUSION@#The digital manufacturing of simple intraoral Gothic arch-tracing device can be used to determine the centric relation of complete dentures, which can not only save time of clinical operation, but also ensure the accuracy of the centric relation.


Asunto(s)
Humanos , Relación Céntrica , Registro de la Relación Maxilomandibular/métodos , Dentadura Completa , Boca Edéntula , Arcada Edéntula
20.
Clin Oral Investig ; 27(2): 489-504, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36577849

RESUMEN

BACKGROUND: To explore the digitisation of jaw movement trajectories through devices and discuss the physiological factors and device-dependent variables with their subsequent effects on the jaw movement analyses. METHODS: Based on predefined eligibility criteria, the search was conducted following PRISMA-P 2015 guidelines on MEDLINE, EBSCO Host, Scopus, PubMed, and Web of Science databases in 2022 by 2 reviewers. Articles then underwent Cochrane GRADE approach and JBI critical appraisal for certainty of evidence and bias evaluation. RESULTS: Thirty articles were included following eligibility screening. Both in vitro experiments (20%) and in vivo (80%) devices ranging from electronic axiography, electromyography, optoelectronic and ultrasonic, oral or extra-oral tracking, photogrammetry, sirognathography, digital pressure sensors, electrognathography, and computerised medical-image tracing were documented. 53.53% of the studies were rated below "moderate" certainty of evidence. Critical appraisal showed 80% case-control investigations failed to address confounding variables while 90% of the included non-randomised experimental studies failed to establish control reference. CONCLUSION: Mandibular and condylar growth, kinematic dysfunction of the neuromuscular system, shortened dental arches, previous orthodontic treatment, variations in habitual head posture, temporomandibular joint disorders, fricative phonetics, and to a limited extent parafunctional habits and unbalanced occlusal contact were identified confounding variables that shaped jaw movement trajectories but were not highly dependent on age, gender, or diet. Realistic variations in device accuracy were found between 50 and 330 µm across the digital systems with very low interrater reliability for motion tracing from photographs. Forensic and in vitro simulation devices could not accurately recreate variations in jaw motion and muscle contractions.


Asunto(s)
Mandíbula , Movimiento , Registro de la Relación Maxilomandibular/métodos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA