Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 2.492
1.
BMJ Open ; 14(5): e085044, 2024 May 06.
Article En | MEDLINE | ID: mdl-38719285

BACKGROUND: Venous access in patients with obesity presents significant challenges. The success of central venous catheterisation largely depends on the cross-sectional area (CSA) of the internal jugular vein (IJV). While techniques like the Trendelenburg position have been traditionally used to increase IJV CSA, recent studies suggest its ineffectiveness in patients with obesity. Conversely, the potential of the effect of passive leg raising (PLR) has not been thoroughly investigated in this group of patients. METHODS: This protocol outlines a planned randomised controlled trial to evaluate the effect of PLR on the CSA of the IJV in patients with obesity slated for central venous catheterisation. The protocol involves dividing 40 participants into two groups: one undergoing PLR and another serving as a control group without positional change. The protocol specifies measuring the CSA of the IJV via ultrasound as the primary outcome. Secondary outcomes will include the success rates of right IJV cannulation. The proposed statistical approach includes the use of t-tests to compare the changes in CSA between the two groups, with a significance threshold set at p<0.05. ETHICS APPROVAL: This study has been approved by the Institutional Review Board of Shanghai Tongren Hospital. All the participants will provide informed consent prior to enrolment in the study. Regarding the dissemination of research findings, we plan to share the results through academic conferences and peer-reviewed publications. Additionally, we will communicate our findings to the public and professional communities, including patient advocacy groups. TRIAL REGISTRATION NUMBER: ChiCTR: ChiCTR2400080513.


Catheterization, Central Venous , Jugular Veins , Leg , Obesity , Humans , Jugular Veins/diagnostic imaging , Obesity/therapy , Catheterization, Central Venous/methods , Leg/blood supply , Leg/diagnostic imaging , Randomized Controlled Trials as Topic , Patient Positioning/methods , Ultrasonography , Adult , Female , Male
2.
BMC Endocr Disord ; 24(1): 49, 2024 Apr 23.
Article En | MEDLINE | ID: mdl-38654262

BACKGROUND: Papillary thyroid carcinoma (PTC), being the most common thyroid malignancy, is a slow-growing tumor and is usually limited to the thyroid. Extra thyroid extension is uncommon; besides, invasion to the vasculature seems to be extremely rare and usually indicates aggressive nature of the disease. CASE PRESENTATION: We present a case of a 40-year-old lady who referred with a palpable neck mass a month after total thyroidectomy which its histopathologic examination revealed follicular variant of PTC; the same variant as prior thyroidectomy. Preoperative ultrasonography failed to comment on the intravascular component of the mass. Surgical procedure confirmed a mass attaching and infiltrating to the internal jugular vein, which turned out to be persistent disease. CONCLUSIONS: Awareness of this entity is important for surgeons, oncologists and radiologist as it can influence patient management.


Carcinoma, Papillary , Jugular Veins , Thyroid Cancer, Papillary , Thyroid Neoplasms , Thyroidectomy , Humans , Jugular Veins/pathology , Jugular Veins/diagnostic imaging , Female , Adult , Thyroid Neoplasms/pathology , Thyroid Neoplasms/surgery , Thyroid Neoplasms/diagnosis , Thyroid Neoplasms/diagnostic imaging , Thyroid Cancer, Papillary/surgery , Thyroid Cancer, Papillary/pathology , Carcinoma, Papillary/pathology , Carcinoma, Papillary/surgery , Carcinoma, Papillary/diagnostic imaging , Carcinoma, Papillary/diagnosis , Neoplasm Invasiveness , Prognosis
7.
J Appl Physiol (1985) ; 136(5): 1105-1112, 2024 May 01.
Article En | MEDLINE | ID: mdl-38482574

During spaceflight, fluids shift headward, causing internal jugular vein (IJV) distension and altered hemodynamics, including stasis and retrograde flow, that may increase the risk of thrombosis. This study's purpose was to determine the effects of acute exposure to weightlessness (0-G) on IJV dimensions and flow dynamics. We used two-dimensional (2-D) ultrasound to measure IJV cross-sectional area (CSA) and Doppler ultrasound to characterize venous blood flow patterns in the right and left IJV in 13 healthy participants (6 females) while 1) seated and supine on the ground, 2) supine during 0-G parabolic flight, and 3) supine during level flight (at 1-G). On Earth, in 1-G, moving from seated to supine posture increased CSA in both left (+62 [95% CI: +42 to 81] mm2, P < 0.0001) and right (+86 [95% CI: +58 to 113] mm2, P < 0.00012) IJV. Entry into 0-G further increased IJV CSA in both left (+27 [95% CI: +5 to 48] mm2, P = 0.02) and right (+30 [95% CI: +0.3 to 61] mm2, P = 0.02) relative to supine in 1-G. We observed stagnant flow in the left IJV of one participant during 0-G parabolic flight that remained during level flight but was not present during any imaging during preflight measures in the seated or supine postures; normal venous flow patterns were observed in the right IJV during all conditions in all participants. Alterations to cerebral outflow dynamics in the left IJV can occur during acute exposure to weightlessness and thus, may increase the risk of venous thrombosis during any duration of spaceflight.NEW & NOTEWORTHY The absence of hydrostatic pressure gradients in the vascular system and loss of tissue weight during weightlessness results in altered flow dynamics in the left internal jugular vein in some astronauts that may contribute to an increased risk of thromboembolism during spaceflight. Here, we report that the internal jugular veins distend bilaterally in healthy participants and that flow stasis can occur in the left internal jugular vein during acute weightlessness produced by parabolic flight.


Jugular Veins , Weightlessness , Humans , Female , Jugular Veins/physiology , Jugular Veins/diagnostic imaging , Male , Adult , Weightlessness/adverse effects , Space Flight/methods , Hemodynamics/physiology , Blood Flow Velocity/physiology , Supine Position/physiology , Young Adult
8.
Surg Radiol Anat ; 46(5): 669-677, 2024 May.
Article En | MEDLINE | ID: mdl-38536426

PURPOSE: The superficial venous system (SVS) of the neck receives blood from the face and oral cavity. The SVS comprises the anterior jugular vein (AJV), external jugular vein (EJV), and facial vein (FV). Comprehensive knowledge of the normal anatomy and potential variations in the venous system is valuable in surgical and radiological procedures. This study aimed to update the anatomic knowledge of the SVS using a radiographic approach, which is a beneficial data source in clinical practice. METHODS: Contrast-enhanced computed tomography images of the neck of patients with head and neck cancer treated between 2017 and 2020 were retrospectively evaluated. Each side of the neck was counted separately. A total of 302 necks of 151 patients were enrolled in this study. RESULTS: The medial AJV was absent in 49.7% (75/151) of the patients on the left side, which was significantly greater than the 19.2% (29/151) on the right (p < 0.001). The left AJV drained into the right venous system in 6.6% (10/151) of the necks. In 48.3% (146/302) of the necks, the FV did not flow into the internal jugular vein but rather into the EJV or AJV; these findings were significantly more frequent than those reported in previous studies. The diameters of the veins were significantly larger when they received blood from the FV than when they were not connected to the FV. CONCLUSION: These findings indicate that the AJV has a rightward preference during its course. The course of the FV is diverse and affects the diameter of connected veins.


Anatomic Variation , Contrast Media , Head and Neck Neoplasms , Jugular Veins , Neck , Tomography, X-Ray Computed , Humans , Male , Female , Contrast Media/administration & dosage , Middle Aged , Neck/blood supply , Neck/diagnostic imaging , Aged , Jugular Veins/diagnostic imaging , Jugular Veins/anatomy & histology , Retrospective Studies , Head and Neck Neoplasms/diagnostic imaging , Head and Neck Neoplasms/blood supply , Adult , Aged, 80 and over
9.
Am J Emerg Med ; 78: 206-214, 2024 Apr.
Article En | MEDLINE | ID: mdl-38330835

BACKGROUND: Ultrasound-guided central venous catheterization (CVC) has become the standard of care. However, providers use a variety of approaches, encompassing the internal jugular vein (IJV), supraclavicular subclavian vein (SupraSCV), infraclavicular subclavian vein (InfraSCV), proximal axillary vein (ProxiAV), distal axillary vein (DistalAV), and femoral vein. OBJECTIVE: This review aimed to compare the first-pass success rate and arterial puncture rate for different approaches to ultrasound-guided CVC above the diaphragm. METHODS: In May 2023, Embase, MEDLINE, CENTRAL, ClinicalTrials.gov, and World Health Organization International Clinical Trials Platform were searched for randomized controlled trials (RCTs) comparing the 5 CVC approaches. The Confidence in Network Meta-Analysis tool was used to assess confidence. Thirteen RCTs (4418 participants and 13 comparisons) were included in this review. RESULTS: The SupraSCV approach likely increased the proportion of first-attempt successes compared to the other 4 approaches. The SupraSCV first-attempt success demonstrated risk ratios (RRs) > 1.21 with a lower 95% confidence interval (CI) exceeding 1. Compared to the IJV, the SupraSCV approach likely increased the first-attempt success proportion (RR 1.22; 95% confidence interval [CI] 1.06-1.40, moderate confidence), whereas the DistalAV approach reduced it (RR 0.72; 95% CI 0.59-0.87, high confidence). Artery puncture had little to no difference across all approaches (low to high confidence). CONCLUSION: Considering first-attempt success and mechanical complications, the SupraSCV may emerge as the preferred approach, while DistalAV might be the least preferable approach. Nevertheless, head-to-head studies comparing the approaches with the greatest first attempt success should be undertaken.


Catheterization, Central Venous , Humans , Network Meta-Analysis , Ultrasonography, Interventional , Subclavian Vein/diagnostic imaging , Brachiocephalic Veins , Jugular Veins/diagnostic imaging
10.
Circ Heart Fail ; 17(2): e010973, 2024 02.
Article En | MEDLINE | ID: mdl-38299348

BACKGROUND: Clinical evaluation of central venous pressure is difficult, depends on experience, and is often inaccurate in patients with chronic advanced heart failure. We assessed the ultrasound-assessed internal jugular vein (JV) distensibility by ultrasound as a noninvasive tool to identify patients with normal right atrial pressure (RAP ≤7 mm Hg) in this population. METHODS: We measured JV distensibility as the Valsalva-to-rest ratio of the vein diameter in a calibration cohort (N=100) and a validation cohort (N=101) of consecutive patients with chronic heart failure with reduced ejection fraction who underwent pulmonary artery catheterization for advanced heart failure therapies workup. RESULTS: A JV distensibility threshold of 1.6 was identified as the most accurate to discriminate between patients with RAP ≤7 versus >7 mm Hg (area under the receiver operating characteristic curve, 0.74 [95% CI, 0.64-0.84]) and confirmed in the validation cohort (receiver operating characteristic, 0.82 [95% CI, 0.73-0.92]). A JV distensibility ratio >1.6 had predictive positive values of 0.86 and 0.94, respectively, to identify patients with RAP ≤7 mm Hg in the calibration and validation cohorts. Compared with patients from the calibration cohort with a high JV distensibility ratio (>1.6; n=42; median RAP, 4 mm Hg; pulmonary capillary wedge pressure, 11 mm Hg), those with a low JV distensibility ratio (≤1.6; n=58; median RAP, 8 mm Hg; pulmonary capillary wedge pressure, 22 mm Hg; P<0.0001 for both) were more likely to die or undergo a left ventricular assist device implant or heart transplantation (event rate at 2 years: 42.7% versus 18.2%; log-rank P=0.034). CONCLUSIONS: Ultrasound-assessed JV distensibility identifies patients with chronic advanced heart failure with normal RAP and better outcomes. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03874312.


Heart Failure , Humans , Atrial Pressure , Cardiac Catheterization , Catheterization, Swan-Ganz , Heart Failure/diagnostic imaging , Heart Failure/therapy , Jugular Veins/diagnostic imaging , Pulmonary Wedge Pressure , Stroke Volume
11.
Acta Anaesthesiol Scand ; 68(4): 520-529, 2024 Apr.
Article En | MEDLINE | ID: mdl-38351546

BACKGROUND: There is a paucity of data on the incidence of central venous catheter tip misplacements after the implementation of ultrasound guidance during insertion. The aims of the present study were to determine the incidence of tip misplacements and to identify independent variables associated with tip misplacement. METHODS: All jugular and subclavian central venous catheter insertions in patients ≥16 years with a post-procedural chest radiography at four hospitals were included. Each case was reviewed for relevant catheter data and radiologic evaluations of chest radiographies. Tip misplacements were classified as 'any tip misplacement', 'minor tip misplacement' or 'major tip misplacement'. Multivariable logistic regression analyses were used to investigate associations between predefined independent variables and tip misplacements. RESULTS: A total of 8556 central venous catheter insertions in 5587 patients were included. Real-time ultrasound guidance was used in 91% of all insertions. Any tip misplacement occurred (95% confidence interval) in 3.7 (3.3-4.1)% of the catheterisations, and 2.1 (1.8-2.4)% were classified as major tip misplacements. The multivariable logistic regression analyses showed that female patient gender, subclavian vein insertions, number of skin punctures and limited operator experience were associated with a higher risk of major tip misplacement, whereas increasing age and height were associated with a lower risk. CONCLUSIONS: In this large prospective multicentre cohort study, performed in the ultrasound-guided era, we demonstrated the incidence of tip misplacements to be 3.7 (3.3-4.1)%. Right internal jugular vein catheterisation had the lowest incidence of both minor and major tip misplacement.


Catheterization, Central Venous , Central Venous Catheters , Humans , Female , Catheterization, Central Venous/adverse effects , Central Venous Catheters/adverse effects , Prospective Studies , Cohort Studies , Ultrasonography , Jugular Veins/diagnostic imaging , Ultrasonography, Interventional
12.
Tomography ; 10(2): 266-276, 2024 Feb 11.
Article En | MEDLINE | ID: mdl-38393289

OBJECTIVE: Internal Jugular Vein Stenosis (IJVS) is hypothesized to play a role in the pathogenesis of diverse neurological diseases. We sought to evaluate differences in IJVS assessment between CT and MRI in a retrospective patient cohort. METHODS: We included consecutive patients who had both MRI of the brain and CT of the head and neck with contrast from 1 June 2021 to 30 June 2022 within the same admission. The degree of IJVS was categorized into five grades (0-IV). RESULTS: A total of 35 patients with a total of 70 internal jugular (IJ) veins were included in our analysis. There was fair intermodality agreement in stenosis grades (κ = 0.220, 95% C.I. = [0.029, 0.410]), though categorical stenosis grades were significantly discordant between imaging modalities, with higher grades more frequent in MRI (χ2 = 27.378, p = 0.002). On CT-based imaging, Grade III or IV stenoses were noted in 17/70 (24.2%) IJs, whereas on MRI-based imaging, Grade III or IV stenoses were found in 40/70 (57.1%) IJs. Among veins with Grade I-IV IJVS, MRI stenosis estimates were significantly higher than CT stenosis estimates (77.0%, 95% C.I. [35.9-55.2%] vs. 45.6%, 95% C.I. [35.9-55.2%], p < 0.001). CONCLUSION: MRI with contrast overestimates the degree of IJVS compared to CT with contrast. Consideration of this discrepancy should be considered in diagnosis and treatment planning in patients with potential IJVS-related symptoms.


Jugular Veins , Vascular Diseases , Humans , Constriction, Pathologic/diagnostic imaging , Constriction, Pathologic/pathology , Jugular Veins/diagnostic imaging , Jugular Veins/pathology , Retrospective Studies , Magnetic Resonance Imaging , Vascular Diseases/pathology , Tomography, X-Ray Computed
13.
Am J Case Rep ; 25: e943270, 2024 Feb 21.
Article En | MEDLINE | ID: mdl-38379277

BACKGROUND Hyperparathyroidism is a common issue in patients on long-term hemodialysis, necessitating parathyroidectomy with deep venipuncture. These patients frequently exhibit a heightened incidence of vascular calcification, complicating deep venipuncture and increasing the risk of associated complications. Therefore, a crucial aspect of preoperative assessment in this population involves identifying vascular calcification, with a preference for ultrasound-guided intraplane puncture. Special care is required to prevent blood vessel injuries and postoperative complications such as deep vein thrombosis. CASE REPORT We present the case of a 66-year-old woman with secondary hyperparathyroidism who encountered challenges during an internal jugular vein puncture, leading to subsequent thrombosis. Initial attempts were hindered by calcification of the internal jugular vein's vascular wall, resulting in stratified damage to the vessel's wall. However, the ultrasound-guided in-plane puncture technique successfully allowed the insertion of a central venous catheter without further damage to the vascular wall. On the postoperative fourth day, thrombus formation was observed in the damaged vascular wall from the initial puncture. CONCLUSIONS The ultrasound-guided in-plane puncture technique is advantageous in overcoming the difficulties associated with puncturing through deep vein calcification in patients with secondary hyperparathyroidism. This technique also diminishes the likelihood of complications such as venous thrombosis.


Catheterization, Central Venous , Hyperparathyroidism, Secondary , Thrombosis , Vascular Calcification , Female , Humans , Aged , Catheterization, Central Venous/adverse effects , Phlebotomy , Jugular Veins/diagnostic imaging , Ultrasonography, Interventional/methods , Hyperparathyroidism, Secondary/surgery
15.
J Clin Ultrasound ; 52(4): 456-463, 2024 May.
Article En | MEDLINE | ID: mdl-38169054

Hemodialysis (HD) arteriovenous fistulas commonly present with late vascular access complications, but are rarely in association with internal jugular vein (IJV) reflux. We reported two patients who had severe and mild IJV reflux, respectively. Case 1 was a 48-year-old male with end-stage renal disease (ESRD) who had been treated with HD for 5 years. He presented with persistent headaches, nausea, and vomiting. Combined with all the examinations, it was revealed severe IJV reflux, brachiocephalic vein stenosis, high-flow vascular access, and IJV valve dysfunction. Case 2 was a 59-year-old female with ESRD who had constructed an AVF for 4 months and had been on HD for only 1 day. She presented with dizziness and nausea after the first hemodialysis and duplex ultrasonography showed slightly continuous IJV reflux, high-flow vascular access, and IJV valve dysfunction. Furthermore, we reviewed 16 case reports to identify the characteristics of IJV reflux in HD patients. IJV reflux in HD patients may be caused by high-flow access, central venous stenosis or occlusion, and valve dysfunction. Severe IJV reflux can develop neurological symptoms secondary to intracranial venous reflux in this article. Etiological treatment is helpful for these patients, but there is a risk of recurrence.


Jugular Veins , Kidney Failure, Chronic , Renal Dialysis , Humans , Middle Aged , Jugular Veins/diagnostic imaging , Male , Female , Kidney Failure, Chronic/therapy , Kidney Failure, Chronic/complications , Arteriovenous Shunt, Surgical/adverse effects , Ultrasonography, Doppler, Duplex/methods
17.
Int J Med Sci ; 21(3): 431-438, 2024.
Article En | MEDLINE | ID: mdl-38250605

This prospective observational study investigated the optimal insertion depth of the central venous catheter through the right internal jugular vein using transesophageal echocardiography. After tracheal intubation, the anesthesiologist inserted a probe for esophageal echocardiography into the patient's esophagus. The investigators placed the catheter tip 2 cm above the superior edge of the crista terminalis with echocardiography, which was defined as the optimal point. We measured the inserted length of the catheter. Pearson correlation tests were performed with the measured optimal depth and some patient parameters. We made a new formula for placing the catheter at the optimal position. A total of 89 subjects were enrolled in this trial. The correlation coefficient between the measured optimal depth and the patient's parameters was the highest for patient height (0.703, p < 0.001). We made a new formula of 'height (cm)/10 - 1.5 cm'. The accuracy rate of this formula for the optimal zone was 71.9% (95% confidence interval; 62.4 - 81.4%), which was the highest among the previous formulas or guidelines when we compared. In conclusion, the central venous catheter tip was evaluated with transesophageal echocardiography, and we could make a new formula of 'height (cm)/10 - 1.5', which seemed to be better than other previous guidelines.


Central Venous Catheters , Humans , Echocardiography , Echocardiography, Transesophageal , Heart Atria , Jugular Veins/diagnostic imaging , Prospective Studies
18.
Clin Hemorheol Microcirc ; 86(1-2): 133-142, 2024.
Article En | MEDLINE | ID: mdl-37742633

AIM: First assessment of flow changes in the jugular veins using high resolution ultrasound vector flow. MATERIAL UND METHODS: 15 patients (8 males, 7 females) with an age range of 35 to 82 years (mean age 58.53±12.26 years) were examined by an experienced examiner using high power ultrasound equipment (Resona R9, Mindray) with probe technology (Mindray L9-3U Linear Array transducer, 2.5 to 9.0 MHz). This group was compared with five healthy subjects (mean age 35.4±13.79 years) as a reference. To assess flow changes, the color-coded duplex sonography and the novel vector flow technique were used. The evaluation was performed of vector morphology changes, turbulence, and wall resistance measurements. RESULTS: There were changes after acute and chronic thrombosis in 9 cases, and venous compression in 7 cases. Turbulence was measurable from 0.01 % to 64.44 %, the average turbulence was 19.73±22.06 %. Wall resistance measurement showed values from 0.01 Pa to 3.14 Pa, depending on the age of the thrombosis or compression. The reference veins showed turbulence of 0.94±1.5 % and a mean wall resistance of 0.05±0.05 Pa. There are statistically significant differences between normal and thrombotic or compressed veins in terms of maximum wall stress (p = 0.006) and mean degree of turbulence (p = 0.012), while the difference in mean wall stress is not statistically significant (p = 0.058). CONCLUSION: Despite still existing technical limitations, the combination of V-flow and wall stress measurements in jugular vein changes suggests a high diagnostic potential.


Jugular Veins , Thrombosis , Male , Female , Humans , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Jugular Veins/diagnostic imaging , Veins , Thrombosis/diagnostic imaging , Ultrasonography, Doppler, Duplex
19.
Clin Neuroradiol ; 34(1): 67-74, 2024 Mar.
Article En | MEDLINE | ID: mdl-37552244

BACKGROUND AND PURPOSE: There has been limited literature regarding the bridging veins (BVs) of the medulla oblongata around the foramen magnum (FM). The present study aims to analyze the normal angioarchitecture of the BVs around the FM using slab MIP images of three-dimensional (3D) angiography. METHODS: We collected 3D angiography data of posterior fossa veins and analyzed the BVs around the FM using slab MIP images. We analyzed the course, outlet, and number of BVs around the FM. We also examined the detection rate and mean diameter of each BV. RESULTS: Of 57 patients, 55 patients (96%) had any BV. The median number of BVs was two (range: 0-5). The BVs originate from the perimedullary veins and run anterolaterally to join the anterior condylar vein (ACV), inferior petrosal sinus, sigmoid sinus, or jugular bulb, inferolaterally to join the suboccipital cavernous sinus (SCS), laterally or posterolaterally to join the marginal sinus (MS), and posteriorly to join the MS or occipital sinus. We classified BVs into five subtypes according to the draining location: ACV, jugular foramen (JF), MS, SCS, and cerebellomedullary cistern (CMC). ACV, JF, MS, SCS, and CMC BVs were detected in 11 (19%), 18 (32%), 32 (56%), 20 (35%), and 16 (28%) patients, respectively. The mean diameter of the BVs other than CMC was 0.6 mm, and that of CMC BV was 0.8 mm. CONCLUSION: Using venous data from 3D angiography, we detected FM BVs in most cases, and the BVs were connected in various directions.


Cerebral Veins , Foramen Magnum , Humans , Foramen Magnum/diagnostic imaging , Cranial Sinuses , Cerebral Veins/diagnostic imaging , Jugular Veins/diagnostic imaging , Jugular Veins/anatomy & histology , Angiography
20.
Vasc Endovascular Surg ; 58(2): 136-141, 2024 Feb.
Article En | MEDLINE | ID: mdl-37634940

AIM: The impact of technical differences in cannulation technique for tunnelled haemodialysis catheter insertion is undetermined. We aimed to assess clinical outcomes of the low posterior approach for internal jugular vein tunnelled catheter placement. METHODS: A retrospective audit was undertaken on consecutive tunnelled catheter procedures performed at a single centre between January 2016 and June 2022. Only catheters specifically placed with a low posterior internal jugular approach were included. The study's primary outcome was 12-month catheter survival, evaluated using the Kaplan-Meier survival curve and log-rank test. Secondary outcomes included catheter performance and procedure-related complications. RESULTS: During the study period, 391 tunnelled internal jugular haemodialysis catheters were inserted in 272 patients using the low posterior technique. The 12-month primary patency rate was 68%. Catheter insertion was successful in 96% of cases. Peri-procedural complications occurred in 4% of cases, most frequently bleeding. The most common reasons for catheter loss were dysfunction (10%) and bacteraemia (6%). The best predictors of catheter failure were advanced age (HR 1.02, 95% CI 1.00-1.04) and in-centre dialysis treatment locality (HR 2.04, 95% CI 1.19-3.45). CONCLUSION: The low posterior approach for internal jugular vein tunnelled catheter insertion is effective and safe. We demonstrated a 12-month catheter survival rate of 68%. Further research comparing the low posterior approach with other internal jugular vein cannulation techniques is warranted.


Catheterization, Central Venous , Catheters, Indwelling , Humans , Retrospective Studies , Jugular Veins/diagnostic imaging , Treatment Outcome , Catheterization, Central Venous/adverse effects , Renal Dialysis
...