Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 1.257
1.
Int J Mol Sci ; 25(9)2024 Apr 24.
Article En | MEDLINE | ID: mdl-38731845

Moringa oleifera leaves are rich sources of bioactive compounds with potential health benefits, including antioxidants and anti-inflammatory agents. Pressurized liquid extraction (PLE) stands out as a promising technique for effectively extracting valuable compounds from natural sources. In this study, we aimed to optimize PLE parameters, such as temperature, extraction duration, and pressure, to maximize bioactive compound (polyphenols, flavonoids, and ascorbic acid) yield from M. oleifera leaves and evaluate their antioxidant and anti-inflammatory activities. According to the outcomes of this research, the maximum achieved total polyphenol content was 24.10 mg gallic acid equivalents (GAE)/g of dry weight (dw), and the total flavonoid content was increased up to 19.89 mg rutin equivalents (RtE)/g dw. Moreover, after HPLC-DAD analysis, neochlorogenic and chlorogenic acids, catechin and epicatechin, rutin, and narirutin were identified and quantified. As far as the optimum ascorbic acid content is concerned, it was found to be 4.77 mg/g dw. The antioxidant activity was evaluated by three different methods: ferric reducing antioxidant power (FRAP), the DPPH method, and the anti-hydrogen peroxide activity (AHPA) method, resulting in 124.29 µmol ascorbic acid equivalent (AAE)/g dw, 131.28 µmol AAE/g dw, and 229.38 µmol AAE/g dw values, respectively. Lastly, the albumin denaturation inhibition was found to be 37.54%. These findings underscore the potential of PLE as an efficient extraction method for preparing extracts from M. oleifera leaves with the maximum content of bioactive compounds.


Antioxidants , Moringa oleifera , Plant Extracts , Plant Leaves , Moringa oleifera/chemistry , Plant Leaves/chemistry , Antioxidants/pharmacology , Antioxidants/chemistry , Antioxidants/isolation & purification , Plant Extracts/pharmacology , Plant Extracts/chemistry , Flavonoids/isolation & purification , Flavonoids/analysis , Flavonoids/chemistry , Flavonoids/pharmacology , Polyphenols/isolation & purification , Polyphenols/pharmacology , Polyphenols/analysis , Polyphenols/chemistry , Ascorbic Acid/pharmacology , Anti-Inflammatory Agents/pharmacology , Anti-Inflammatory Agents/chemistry , Anti-Inflammatory Agents/isolation & purification , Chromatography, High Pressure Liquid/methods , Pressure , Liquid-Liquid Extraction/methods , Phytochemicals/chemistry , Phytochemicals/pharmacology , Phytochemicals/isolation & purification
2.
J Chromatogr A ; 1726: 464963, 2024 Jul 05.
Article En | MEDLINE | ID: mdl-38723493

The monitoring of organic compounds in aquatic matrices poses challenges due to its complexity and time-intensive nature. To address these challenges, we introduce a novel approach utilizing a dual-channel mono (1D) and comprehensive two-dimensional (2D) gas chromatography coupled with time-of-flight mass spectrometry (GC × GC-TOFMS) system, integrated with a robotic pretreatment platform, for online monitoring of both volatile organic compounds (VOCs) and semivolatile organic compounds (SVOCs) in water matrices. Employing the robotic platform, we establish a suite of online liquid-liquid extraction (LLE) pretreatment processes for water samples, marking the first instance of such procedures. Leveraging the automatic headspace (HS) module, dual robotic preparations of HS and LLE are sequentially executed to extract VOCs and SVOCs from water matrices. The GC × GC-TOFMS system is distinguished by its dual-channel analytical column configuration, facilitating sequential analysis of VOCs in GC-TOFMS mode and SVOCs in GC × GC-TOFMS mode. Quantitative detection of 55 target VOCs and 104 SVOCs is achieved in a water sample using the instrument system. Our method demonstrates excellent correlation coefficients ranging from 0.990 to 1.000, method detection limits ranging from 0.08 to 4.78 µg L-1, relative standard deviations below 19.3 %, and recovery rates ranging from 50.0 % to 124.0 %. To validate the online monitoring capabilities of our system, we assess target SVOCs at three different concentration levels over a 3-day period. Most compounds exhibit recovery rates ranging from 70.0 % to 130.0 %. Furthermore, we apply our method to analyze a real water sample, successfully identifying over 100 target and nontarget VOCs/SVOCs, including alcohols, aldehydes, ketones, acids, esters, and phenols. These results highlight the efficacy of the proposed analysis system, capable of conducting two distinct analyses in automatic sequence, thereby enhancing the efficiency and accuracy of organic compound analysis in water matrices.


Gas Chromatography-Mass Spectrometry , Liquid-Liquid Extraction , Robotics , Volatile Organic Compounds , Volatile Organic Compounds/analysis , Volatile Organic Compounds/isolation & purification , Gas Chromatography-Mass Spectrometry/methods , Liquid-Liquid Extraction/methods , Water Pollutants, Chemical/analysis , Water Pollutants, Chemical/isolation & purification , Limit of Detection
3.
Chemosphere ; 358: 142201, 2024 Jun.
Article En | MEDLINE | ID: mdl-38692367

Thallium (Tl) is a potential toxicity element that poses significant ecological and environmental risks. Recently, a substantial amount of Tl has been released into the environment through natural and human activities, which attracts increasing attention. The determination of this hazardous and trace element is crucial for controlling its pollution. This article summarizes the advancement and progress in optimizing Tl detection techniques, including atomic absorption spectroscopy (AAS), voltammetry, inductively coupled plasma (ICP)-based methods, spectrophotometry, and X-ray-based methods. Additionally, it introduces sampling and pretreatment methods such as diffusive gradients in thin films (DGT), liquid-liquid extraction, solid phase extraction, and cloud point extraction. Among these techniques, ICP-mass spectrometry (MS) is the preferred choice for Tl detection due to its high precision in determining Tl as well as its species and isotopic composition. Meanwhile, some new materials and agents are employed in detection. The application of novel work electrode materials and chromogenic agents is discussed. Emphasis is placed on reducing solvent consumption and utilizing pretreatment techniques such as ultrasound-assisted processes and functionalized magnetic particles. Most detection is performed in aqueous matrices, while X-ray-based methods applied to solid phases are summarized which provide non-destructive analysis. This work improves the understanding of Tl determination technology while serving as a valuable resource for researchers seeking appropriate analytical techniques.


Environmental Monitoring , Thallium , Thallium/analysis , Environmental Monitoring/methods , Environmental Pollutants/analysis , Spectrophotometry, Atomic , Solid Phase Extraction/methods , Mass Spectrometry/methods , Liquid-Liquid Extraction/methods
4.
Anal Chim Acta ; 1307: 342624, 2024 Jun 08.
Article En | MEDLINE | ID: mdl-38719414

BACKGROUND: Pesticides are used in agricultural production for prevent and control crop diseases and pests, but it is easy to cause excessive pesticides residues in agricultural products, polluting the environment and endangering human health. Due to their unmatched and sustainable capabilities, nanoextraction procedures are becoming every day more important in Analytical Chemistry. In particular, nanoconfined liquid phase extraction has shown extraction capabilities toward polar, medium polar, and/or nonpolar substances, which can be easily modulated depending on the nanoconfined solvent used. Furthermore, this "green" technique showed excellent characteristics in terms of recoveries, extraction time (≤1 min), reliability, and versatility. (97) RESULTS: In this work, the advantages of this technique have been coupled with those of filtration membrane extraction, making use of carbon nanofibers (CnFs) growth on carbon microspheres (CµS). This substrate has been deposited on a filter, which combined with gas chromatographic mass spectrometry (GC-MS) analysis successfully employed for the nanoextraction of 30 pesticides (18 organochlorine and 12 pyrethroids) in tea samples. Under the optimized extraction conditions, the linear range with standard solutions was from 1 to 1000 ng mL-1 (R2 ≥ 0.99), the limit of detections in tea samples were in the range 0.56-17.98 µg kg-1. The accuracy of the developed method was evaluated by measuring the extraction recovery of the spiked tea samples, and recoveries between 74.41 % and 115.46 %. (119) SIGNIFICANCE: Considering the versatility of nanoconfined liquid phase extraction and the functionality of the filtration membrane extraction procedure, this new extraction method can be considered a powerful candidate for automatized high-throughput analyses of real samples. (34).


Filtration , Hydrocarbons, Chlorinated , Liquid-Liquid Extraction , Pesticides , Pyrethrins , Tea , Tea/chemistry , Pyrethrins/analysis , Pyrethrins/isolation & purification , Hydrocarbons, Chlorinated/analysis , Hydrocarbons, Chlorinated/isolation & purification , Liquid-Liquid Extraction/methods , Filtration/methods , Pesticides/analysis , Pesticides/isolation & purification , Gas Chromatography-Mass Spectrometry/methods , Membranes, Artificial
5.
Sci Rep ; 14(1): 10157, 2024 05 02.
Article En | MEDLINE | ID: mdl-38698072

Extraction of nucleic acids (NAs) is critical for many methods in molecular biology and bioanalytical chemistry. NA extraction has been extensively studied and optimized for a wide range of applications and its importance to society has significantly increased. The COVID-19 pandemic highlighted the importance of early and efficient NA testing, for which NA extraction is a critical analytical step prior to the detection by methods like polymerase chain reaction. This study explores simple, new approaches to extraction using engineered smart nanomaterials, namely NA-binding, intrinsically disordered proteins (IDPs), that undergo triggered liquid-liquid phase separation (LLPS). Two types of NA-binding IDPs are studied, both based on genetically engineered elastin-like polypeptides (ELPs), model IDPs that exhibit a lower critical solution temperature in water and can be designed to exhibit LLPS at desired temperatures in a variety of biological solutions. We show that ELP fusion proteins with natural NA-binding domains can be used to extract DNA and RNA from physiologically relevant solutions. We further show that LLPS of pH responsive ELPs that incorporate histidine in their sequences can be used for both binding, extraction and release of NAs from biological solutions, and can be used to detect SARS-CoV-2 RNA in samples from COVID-positive patients.


COVID-19 , Elastin , Peptides , SARS-CoV-2 , Elastin/chemistry , Hydrogen-Ion Concentration , Peptides/chemistry , COVID-19/virology , SARS-CoV-2/isolation & purification , SARS-CoV-2/genetics , Humans , Intrinsically Disordered Proteins/chemistry , Liquid-Liquid Extraction/methods , Nucleic Acids/isolation & purification , Nucleic Acids/chemistry , DNA/chemistry , DNA/isolation & purification , Elastin-Like Polypeptides , Phase Separation
6.
J Sep Sci ; 47(9-10): e2400142, 2024 May.
Article En | MEDLINE | ID: mdl-38726732

Catechins, renowned for their antioxidant properties and health benefits, are commonly present in beverages, particularly tea and wine. An efficient and cost-effective salting-out assisted liquid-liquid extraction (SALLE) method has been developed and validated for the simultaneous determination of six catechins and caffeine in tea and wine samples using high-performance liquid chromatography-ultraviolet (HPLC-UV). This method demonstrates outstanding performance: linearity (1-120 µg/mL, r2 > 0.999), accuracy (96.5%-103.4% recovery), and precision (≤14.7% relative standard deviation), meeting validation requirements set by the US Food and Drug Administration. The reduced sample size (0.1 g) minimizes matrix interferences and costs without compromising sensitivity. All analytes were detected in Camellia sinensis teas, with green tea displaying the highest total catechin content (47.5-100.1 mg/mL), followed by white and black teas. Analysis of wine samples reveals the presence of catechin in all red and white wines, and epigallocatechin gallate in all red wine samples, highlighting the impact of winemaking processes on catechin content. The SALLE-HPLC-UV approach represents a green alternative by eliminating organic waste, surpassing conventional dilution methods in specificity and sensitivity for catechin determination. AGREEprep assessment emphasizes the strengths of the SALLE procedure, including material reusability, throughput efficiency, minimal sample requirements, low energy consumption, and the absence of organic waste generation.


Caffeine , Catechin , Liquid-Liquid Extraction , Tea , Wine , Chromatography, High Pressure Liquid/methods , Wine/analysis , Caffeine/analysis , Catechin/analysis , Tea/chemistry , Liquid-Liquid Extraction/methods , Spectrophotometry, Ultraviolet , Ultraviolet Rays
7.
J Chromatogr A ; 1725: 464944, 2024 Jun 21.
Article En | MEDLINE | ID: mdl-38703459

Investigating pesticide exposure and oxidative stress in preschool children is essential for elucidating the determinants of environmental health in early life, with human biomonitoring of urinary pesticide metabolites serving as a critical strategy for achieving this objective. This study demonstrated biomonitoring of 2 phenoxyacetic acid herbicides, 2 organophosphorus pesticide metabolites, and 4 pyrethroid pesticide metabolites in 159 preschool children and evaluated their association with oxidative stress biomarker 8-hydroxydeoxyguanosine. An enzymatic deconjugation process was used to release urinary pesticide metabolites, which were then extracted and enriched by supported liquid extraction, and quantified by ultra-high performance liquid chromatography-tandem mass spectrometry with internal standard calibration. Dichloromethane: methyl tert­butyl ether (1:1, v/v) was optimized as the solvent for supported liquid extraction, and we validated the method for linear range, recovery, matrix effect and method detection limit. Method detection limit of the pesticide metabolites ranged from 0.01 µg/L to 0.04 µg/L, with satisfactory recoveries ranging from 70.5 % to 95.5 %. 2,4,5-Trichlorophenoxyacetic acid was not detected, whereas the other seven pesticide metabolites were detected with frequencies ranging from 10.1 % to 100 %. The concentration of urinary pesticide metabolites did not significantly differ between boys and girls, with the median concentrations being 9.39 µg/L for boys and 4.90 µg/L for girls, respectively. Spearman correlation analysis indicated that significant positive correlations among urinary metabolites. Bayesian kernel machine regression revealed a significant positive association between urinary pesticide metabolites and 8-hydroxydeoxyguanosine. Para-nitrophenol was the pesticide metabolite that contributed significantly to the elevated level of oxidative stress.


8-Hydroxy-2'-Deoxyguanosine , Biological Monitoring , Oxidative Stress , Pesticides , Tandem Mass Spectrometry , Humans , Child, Preschool , Chromatography, High Pressure Liquid/methods , Tandem Mass Spectrometry/methods , Female , Male , Biological Monitoring/methods , Pesticides/urine , Pesticides/metabolism , 8-Hydroxy-2'-Deoxyguanosine/urine , Limit of Detection , Biomarkers/urine , Liquid-Liquid Extraction/methods , Child
8.
Chemosphere ; 358: 142227, 2024 Jun.
Article En | MEDLINE | ID: mdl-38704046

The widespread detection of perfluorooctanoic acid (PFOA) in the environment has raised significant concerns. The standard PFOA analytical method relies on expensive solid-phase extraction (SPE) and liquid chromatography tandem mass spectrometry (LC-MS/MS) instruments, making routine use prohibitive. We herein proposed a cost-effective yet novel enrichment method for determining PFOA at ng L-1 level. This method entailed a two-step sample preparation process: firstly, PFOA was extracted and enriched using a forward-extraction under acidic conditions, followed by a backward-extraction and enrichment step utilizing alkaline water. The enriched samples were subsequently subjected to a common ion chromatography (IC). Results reveal that maintaining a forward-extraction pH below its pKa value (2.8) is essential, as protonated PFOA proves effective in enhancing the enrichment factor (EF). The challenge lied in driving PFOA from forward-extractant to aqueous backward-extractant due to the decreased hydrophobicity of deprotonated PFOA (log Kow2 = 1.0). In addition, we found that evaporating forward-extractant with alkaline backward-extractant (containing 5% methanol) reduced potential analytical uncertainties associated with PFOA evaporation and sorption. Under optimal conditions, the method achieved a detection limit of 9.2 ng L-1 and an impressive EF value of 719. Comparison with SPE-LC-MS/MS confirmed the proposed method as a promising alternative for PFOA determination. Although initially targeted for PFOA, the novel methodology is likely applicable to preconcentration of other poly-fluoroalkyl substances.


Caprylates , Fluorocarbons , Liquid-Liquid Extraction , Tandem Mass Spectrometry , Water Pollutants, Chemical , Caprylates/analysis , Caprylates/chemistry , Fluorocarbons/analysis , Fluorocarbons/isolation & purification , Fluorocarbons/chemistry , Water Pollutants, Chemical/analysis , Tandem Mass Spectrometry/methods , Liquid-Liquid Extraction/methods , Chromatography, Liquid/methods , Solid Phase Extraction/methods , Water/chemistry , Environmental Monitoring/methods
9.
J Pharm Biomed Anal ; 245: 116149, 2024 Aug 01.
Article En | MEDLINE | ID: mdl-38678858

A precise, sensitive, accurate, and validated reverse-phase high-performance liquid chromatography (RP-HPLC) method with a bioanalytical approach was utilized to analyze Cabazitaxel (CBZ) in rat plasma. Comparative research on extraction recoveries was performed between traditional liquid-liquid extraction (LLE) and synthesized graphene oxide (GO) based magnetic solid phase extraction (GO@MSPE). The superparamagnetic hybrid nanosorbent was synthesized using the combination of iron oxide and GO and subsequently applied for extraction and bioanalytical quantification of CBZ from plasma by (HPLC-PDA) analysis. Fourier- transform infrared spectroscopy (FT-IR), particle size, scanning electron microscopy (SEM), and x-ray diffraction (XRD) analysis were employed in the characterization of synthesized GO@MSPE nanosorbent. The investigation was accomplished using a shim pack C18 column (150 mm×4.6 mm, 5 µm) with a binary gradient mobile phase consisting of formic acid: acetonitrile: water (0.1:75:25, v/v/v) at a 0.8 mL/min flow rate, and a λmax of 229 nm. The limits of detection (LOD) and quantitation (LOQ) have been determined to be 50 and 100 ng/mL for both LLE and SPE techniques. The linearity range of the approach encompassed from 100 to 5000 ng/mL and was found to be linear (coefficient of determination > 0.99) for CBZ. The proposed method showed extraction recovery of 76.8-88.4% for the synthesized GO@MSPE and 69.3-77.4% for LLE, suggesting that the proposed bioanalytical approach was robust and qualified for all validation parameters within the acceptable criteria. Furthermore, the developed hybrid GO@MSPE nanosorbent with the help of the proposed RP-HPLC method, showed a significant potential for the extraction of CBZ in bioanalysis.


Graphite , Limit of Detection , Liquid-Liquid Extraction , Solid Phase Extraction , Animals , Chromatography, High Pressure Liquid/methods , Rats , Liquid-Liquid Extraction/methods , Graphite/chemistry , Solid Phase Extraction/methods , Taxoids/blood , Taxoids/chemistry , Male , Reproducibility of Results , Spectroscopy, Fourier Transform Infrared/methods
10.
J Pharm Biomed Anal ; 245: 116154, 2024 Aug 01.
Article En | MEDLINE | ID: mdl-38657367

Malaria remains a major health concern, aggravated by emerging resistance of the parasite to existing treatments. The World Health Organization recently endorsed the use of artesunate-pyronaridine to treat uncomplicated malaria. However, there is a lack of clinical pharmacokinetic (PK) data of pyronaridine, particularly in special populations such as children and pregnant women. Existing methods for the quantification of pyronaridine in biological matrices to support PK studies exhibit several drawbacks. These include limited sensitivity, a large sample volume required, and extensive analysis time. To overcome these limitations, an ultra-performance reversed-phase liquid chromatography tandem-mass spectrometry method to determine pyronaridine was developed and validated according to international guidelines. The method enabled fast and accurate quantification of pyronaridine in whole blood across a clinically relevant concentration range of 0.500-500 ng/mL (r2 ≥ 0.9963), with a required sample volume of 50 µL. Pyronaridine was extracted from whole blood using liquid-liquid extraction, effectively eliminating the matrix effect and preventing ion enhancement or suppression. The method achieved a satisfactory reproducible sample preparation recovery of 77%, accuracy (as bias) and precision were within ±8.2% and ≤5.3%, respectively. Stability experiments demonstrated that pyronaridine was stable for up to 315 days when stored at -70°C. Adjustments to the chromatographic system substantially reduced carry-over and improved sensitivity compared to prior methods. The method was successfully applied to quantify pyronaridine in whole blood samples from a selection of pregnant malaria patients participating in the PYRAPREG clinical trial (PACTR202011812241529) in the Democratic Republic of the Congo, demonstrating its suitability to support future PK studies. Furthermore, the enhanced sensitivity allows for the determination of pyronaridine up to 42 days post-treatment initiation, enabling assessment of the terminal elimination half-life.


Antimalarials , Naphthyridines , Tandem Mass Spectrometry , Humans , Antimalarials/blood , Antimalarials/pharmacokinetics , Antimalarials/analysis , Tandem Mass Spectrometry/methods , Naphthyridines/blood , Naphthyridines/pharmacokinetics , Naphthyridines/analysis , Chromatography, High Pressure Liquid/methods , Reproducibility of Results , Female , Liquid-Liquid Extraction/methods , Pregnancy , Malaria/drug therapy , Malaria/blood , Chromatography, Reverse-Phase/methods
11.
Anal Methods ; 16(16): 2513-2521, 2024 Apr 25.
Article En | MEDLINE | ID: mdl-38587209

Sweet tea is a functional herbal tea with anti-inflammatory, anti-diabetic, and other effects, in which phloridzin and trilobatin are two functional compounds. However, the current methods for their quantification are time-consuming, costly, and environmentally unfriendly. In this paper, we propose a rapid method that integrates online pressurized liquid extraction and high-performance liquid chromatography featuring a superficially porous column for fast separation. Moreover, we employ an equal absorption wavelength method to eliminate using multiple standard solutions and relative calibration factors. Our verification process corroborated the technique's selectivity, accuracy, precision, linearity, and detection limitations. Separately, our methodology demonstrated excellent analytical efficiency, cost-effectiveness, and environmental friendliness. Practical application using six distinct batches of sweet tea samples yielded results in congruence with the external standard method. The analytical rate of this technique is up to over 18 times faster than traditional methods, and organic solvent consumption has been reduced to less than 1.5 mL. Therefore, this method provides a valuable way to achieve quality control and green analysis of sweet tea and other herbal teas.


Phlorhizin , Chromatography, High Pressure Liquid/methods , Phlorhizin/analysis , Phlorhizin/chemistry , Teas, Herbal/analysis , Hydrolyzable Tannins/analysis , Liquid-Liquid Extraction/methods , Reproducibility of Results
12.
Anal Bioanal Chem ; 416(13): 3149-3160, 2024 May.
Article En | MEDLINE | ID: mdl-38563959

Bats are the second largest mammalian order and are an endangered species group with a strong need for contamination monitoring. To facilitate non-invasive monitoring of the ecological burden in bat populations, a multiresidue method for the simultaneous quantification of 119 analytes including pesticides, persistent organic pollutants (POPs), active pharmaceutical ingredients (APIs), polycyclic aromatic hydrocarbons (PAHs), UV blockers, plasticizers, and other emerging pollutants in bat guano with gas chromatography tandem mass spectrometry (GC-MS/MS) was developed. Sample preparation and clean-up were performed with a modified QuEChERS approach based on DIN EN 15662. The method uses 1.00 g bat guano as sample with acetonitrile and water for liquid-liquid extraction. Phase separation is assisted by citrate-buffered salting out agent. For clean-up of the extract, primary secondary amine (PSA) was combined with graphitized carbon black (GCB). The lower limits of quantification (LLOQ) ranged between 2.5 and 250 µg kg-1. Linearity was shown in a concentration range from the respective LLOQs to 1250 µg kg-1. The median of the mean recovery was 102.4%. Precision was tested at three concentrations. Method and injection precision were adequate with a relative standard deviation (RSD) below 20%. Furthermore, the comparative analysis with LC-MS/MS demonstrated the reliability of the results and provided a valuable extension of the analytical scope. As proof of concept, three guano samples from a German nursery roost of Myotis myotis were analysed. The results show a time-dependent change in contaminant concentration, highlighting the strong need for non-invasive contamination monitoring of whole bat populations.


Chiroptera , Gas Chromatography-Mass Spectrometry , Limit of Detection , Tandem Mass Spectrometry , Animals , Tandem Mass Spectrometry/methods , Gas Chromatography-Mass Spectrometry/methods , Polycyclic Aromatic Hydrocarbons/analysis , Reproducibility of Results , Liquid-Liquid Extraction/methods , Environmental Monitoring/methods
13.
J Am Chem Soc ; 146(18): 12577-12586, 2024 May 08.
Article En | MEDLINE | ID: mdl-38683934

Dynamic supramolecular assemblies, driven by noncovalent interactions, pervade the biological realm. In the synthetic domain, their counterparts, supramolecular polymers, endowed with remarkable self-repair and adaptive traits, are often realized through bioinspired designs. Recently, controlled supramolecular polymerization strategies have emerged, drawing inspiration from protein self-assembly. A burgeoning area of research involves mimicking the liquid-liquid phase separation (LLPS) observed in proteins to create coacervate droplets and recognizing their significance in cellular organization and diverse functions. Herein, we introduce a novel perspective on synthetic coacervates, extending beyond their established role in synthetic biology as dynamic, membraneless phases to enable structural control in synthetic supramolecular polymers. Drawing parallels with the cooperative growth of amyloid fibrils through LLPS, we present metastable coacervate droplets as dormant monomer phases for controlled supramolecular polymerization. This is achieved via a π-conjugated monomer design that combines structural characteristics for both coacervation through its terminal ionic groups and one-dimensional growth via a π-conjugated core. This design leads to a unique temporal LLPS, resulting in a metastable coacervate phase, which subsequently undergoes one-dimensional growth via nucleation within the droplets. In-depth spectroscopic and microscopic characterization provides insights into the temporal evolution of disordered and ordered phases. Furthermore, to modulate the kinetics of liquid-to-solid transformation and to achieve precise control over the structural characteristics of the resulting supramolecular polymers, we invoke seeding in the droplets, showcasing living growth characteristics. Our work thus opens up new avenues in the exciting field of supramolecular polymerization, offering general design principles and controlled synthesis of precision self-assembled structures in confined environments.


Polymerization , Macromolecular Substances/chemistry , Macromolecular Substances/chemical synthesis , Polymers/chemistry , Polymers/chemical synthesis , Liquid-Liquid Extraction/methods , Molecular Structure , Phase Separation
14.
Biotechnol J ; 19(4): e2400005, 2024 Apr.
Article En | MEDLINE | ID: mdl-38651259

Protein purifications based on phase separations (e.g., precipitation and liquid-liquid extraction) have seen little adoption in commercial protein drug production. To identify barriers, we analyzed the purification performance and economics of 290 phase separation purifications from 168 publications. First, we found that studies using Design of Experiments for optimization achieved significantly greater mean yield and host cell protein log10 removal values than those optimizing one factor at a time (11.5% and 53% increases, respectively). Second, by modeling each reported purification at scales from 10 to 10,000 kg product/year and comparing its cost-effectiveness versus chromatography, we found that cost-effectiveness depends strongly on scale: the fraction of phase separations predicted to be cost-effective at the 10, 100, and 1000 kg/year scales was 8%, 15%, and 43%, respectively. Total cost per unit product depends inversely on input purity, with phase separation being cheaper than chromatography at the 100 kg/year scale in 100% of cases where input purity was ≤ 1%, compared to about 25% of cases in the dataset as a whole. Finally, we identified a simple factor that strongly predicts phase separation process costs: the mass ratio of reagents versus purified product (the "direct materials usage rate"), which explains up to 58% of variation in cost per unit of purified product among all 290 reports, and up to 98% of variation within particular types of phase separation.


Cost-Benefit Analysis , Liquid-Liquid Extraction/methods , Proteins/isolation & purification , Proteins/chemistry , Phase Separation
15.
Spectrochim Acta A Mol Biomol Spectrosc ; 313: 124168, 2024 May 15.
Article En | MEDLINE | ID: mdl-38513420

A typical drug used to treat Parkinson's disease is called rasagiline. It belongs to an assortment of drugs known as monoamine oxidase inhibitors, which function by raising dopamine levels in the brain. This work created a unique spectrofluorimetric method for the analytical assay of rasagiline for the first time. The approach utilized the synergistic utility of the fluorogenic properties of benzofurazan and salting-out assisted liquid-liquid extraction. By combining these techniques an ultrasensitive, and highly selective methodology for the assay of rasagiline was established. Measurements were made of the resultant yellow fluorescent product at 533 nm by applying an excitation wavelength of 475.3 nm. The calibration graph was examined to assess its linearity across a range of 30-600 ng/ml. Through estimation, the limit of detection was discovered to be 8.9 ng/ml, while the quantitation limit was estimated to be 27 ng/ml. All relevant parameters influencing the fulfillment of the developed method were thoroughly examined and tuned. Following the directives set by the (ICH) the suggested approach was confirmed and demonstrated its capability for the accurate determination of rasagiline in tablets, as well as for testing content uniformity. The incorporation of salting-out assisted liquid-liquid extraction technology enables effective tracking of rasagiline in plasma samples, providing a novel and innovative approach for its analysis in biological matrices.


4-Chloro-7-nitrobenzofurazan , Monoamine Oxidase Inhibitors , Sodium Chloride , Monoamine Oxidase Inhibitors/pharmacology , Monoamine Oxidase Inhibitors/therapeutic use , Indans , Liquid-Liquid Extraction/methods
16.
J Biotechnol ; 387: 32-43, 2024 May 20.
Article En | MEDLINE | ID: mdl-38555021

The feasibility of bioprocess development relies heavily on the successful application of primary recovery and purification techniques. Aqueous two-phase extraction (ATPE) disrupts the definition of "unit operation" by serving as an integrative and intensive technique that combines different objectives such as the removal of biomass and integrated recovery and purification of the product of interest. The relative simplicity of processing large samples renders this technique an attractive alternative for industrial bioprocessing applications. However, process development is hindered by the lack of easily predictable partition behaviours, the elucidation of which necessitates a large number of experiments to be conducted. Liquid handling devices can assist to address this problem; however, they are configured to operate using low viscosity fluids such as water and water-based solutions as opposed to highly viscous polymeric solutions, which are typically required in ATPE. In this work, an automated high throughput ATPE process development framework is presented by constructing phase diagrams and identifying the binodal curves for PEG6000, PEG3000, and PEG2000. Models were built to determine viscosity- and volume-independent transfer parameters. The framework provided an appropriate strategy to develop a very precise and accurate operation by exploiting the relationship between different liquid transfer parameters and process error. Process accuracy, measured by mean absolute error, and device precision, evaluated by the coefficient of variation, were both shown to be affected by the mechanical properties, particularly viscosity, of the fluids employed. For PEG6000, the mean absolute error improved by six-fold (from 4.82% to 0.75%) and the coefficient of variation improved by three-fold (from 0.027 to 0.008) upon optimisation of the liquid transfer parameters accounting for the viscosity effect on the PEG-salt buffer utilising ATPE operations. As demonstrated here, automated liquid handling devices can serve to streamline process development for APTE enabling wide adoption of this technique in large scale bioprocess applications.


Polyethylene Glycols , Viscosity , Polyethylene Glycols/chemistry , Water/chemistry , Automation , Liquid-Liquid Extraction/methods
17.
Food Chem ; 447: 138960, 2024 Jul 30.
Article En | MEDLINE | ID: mdl-38461727

Iron Chlorin e6 (ICE6), a star plant growth regulator (PGR) with independent intellectual property rights in China, has demonstrated its efficacy through numerous field experiments. We innovatively employed salting-out assisted liquid-liquid extraction (SALLE) with HPLC-UV/Vis to detect ICE6 residues in water, soil, garlic seeds, and sprouts. Using methanol and a C18 column with acetonitrile: 0.1% phosphoric acid mobile phase (55:45, v:v), we achieved a low LOQ of 0.43 to 0.77 µg kg-1. Calibration curves showed strong linearity (R2 > 0.992) within 0.01 to 5.00 mg kg-1. Inter-day and intra-day recoveries (0.05 to 0.50 mg kg-1) demonstrated high sensitivity and accuracy (recoveries: 75.36% to 107.86%; RSD: 1.03% to 8.78%). Additionally, density functional theory (DFT) analysis aligned UV/Vis spectra and indicated ICE6's first-order degradation (2.03 to 4.94 days) under various environmental conditions, mainly driven by abiotic degradation. This study enhances understanding of ICE6's environmental behavior, aids in risk assessment, and guides responsible use in agroecosystems.


Garlic , Metalloporphyrins , Chromatography, High Pressure Liquid/methods , Hydrolysis , Soil , Liquid-Liquid Extraction/methods
18.
Anal Methods ; 16(11): 1593-1602, 2024 Mar 14.
Article En | MEDLINE | ID: mdl-38404220

In this study, a sample preparation procedure based on salt-induced homogeneous liquid-liquid extraction performed in a narrow-bore tube was used for the preconcentration and extraction of Zn(II), Cu(II), and Cd(II) ions from honey samples. To perform the procedure, a mixture of working solution containing sodium chloride, acetonitrile, and a synthesized deep eutectic solvent (as an extraction solvent) was transferred into a narrow tube filled with solid sodium chloride up to a specific level. As the solution flowed through the tube, tiny droplets of the extraction solvent were formed at the boundary between the solution and salt layer. The droplets moved upwards in the tube and eventually collected as a distinct layer on the top of the solution. The separated phase was removed and dispersed into ionized water. After centrifugation, tiny droplets of the extraction solvent containing the analytes were sedimented at the bottom of the tube. The concentrated analytes were measured using flame atomic absorption spectrophotometry. The linear ranges and extraction recoveries were obtained in the ranges of 1.5-100 µg kg-1 and 89.6-94.8%, respectively. The detection limits ranged from 0.35 to 0.48 µg kg-1. Low relative standard deviations (C = 10 µg L-1, n = 6) of 3.1, 2.8, and 3.4% for Zn(II), Cu(II), and Cd(II), respectively, were obtained. Finally, the optimized method was successfully used in determination of concentration of the selected heavy metal ions in various honey samples.


Honey , Liquid Phase Microextraction , Solvents , Sodium Chloride , Cadmium , Deep Eutectic Solvents , Liquid Phase Microextraction/methods , Liquid-Liquid Extraction/methods , Sodium Chloride, Dietary , Zinc
19.
Food Chem ; 439: 138099, 2024 May 01.
Article En | MEDLINE | ID: mdl-38039613

Heating edible oils generates aldehydes, potentially leading to adverse health effects, making their analysis essential for quality control. This study presents a convenient miniaturized kapok fiber-supported liquid-phase extraction/in-situ derivatization method for the simultaneous extraction and derivatization of aldehydes in oils. The method involves placing 150 mg oil into a 1 mL pipette tip packed with 25 mg kapok fiber, adding 150 µL ACN with 1.5 mg mL-1 DNPH, and post 30-minute static extraction, retrieving the extractant with a pipettor for liquid chromatography-tandem mass spectrometry analysis. By optimizing critical parameters through a Box-Behnken design, the method exhibits good linearity (1-500 ng g-1, R2 ≥ 0.991), low detection limits (0.2-1.0 ng g-1), excellent accuracy (95.3-107.1%) and high precisions (relative standard deviation < 7.9%). This method simplifies sample preparation processes, cuts solvent use, and facilitates automation. It effectively identifies ten aldehyde variations in six heated oils, displaying distinct profiles consistent with prior research.


Aldehydes , Tandem Mass Spectrometry , Tandem Mass Spectrometry/methods , Aldehydes/analysis , Chromatography, Liquid , Liquid-Liquid Extraction/methods , Plant Oils/chemistry , Chromatography, High Pressure Liquid/methods
20.
Article En | MEDLINE | ID: mdl-37793248

Emerging pesticides of neonicotinoids (NEOs) and "Universal Pesticides" (UPs) are a growing global concern due to their growing commercial importance and potential risks to human health. The currently available analytical methods for these pesticides in biomonitoring were usually tailored for limited number of analytes, or were time consuming and costly. In this study, an efficient and sensitive method for the analysis of 16 NEOs and nine UPs in human follicular fluid (FF) was developed by using a salting-out assisted liquid-liquid extraction (SALLE) method and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Method performance was evaluated by calibration linearity (r > 0.99), sensitivity at limits of quantification (0.01-0.50 ng/mL), accuracy at relative recoveries (81-117%) and precision at relative standard deviations (≤16%). The developed method was further validated by analyzing 21 human FF samples that were collected from a hospital in Guangzhou, China. Among the 25 study analytes, two NEOs and six UPs had their detection rates over 85% and medians at 0.048-0.808 ng/mL in the FF samples. Considering the well-known toxicity of these pesticides and their metabolites, it is urgent to figure out exposure profiles of study pesticides and potential reproductive risk for women. To the best of our knowledge, this study is the first to develop and apply the SALLE method in the extraction of 16 NEOs and nine UPs simultaneously in human FF.


Pesticides , Female , Humans , Pesticides/analysis , Chromatography, Liquid/methods , Follicular Fluid/chemistry , Tandem Mass Spectrometry/methods , Liquid-Liquid Extraction/methods , Sodium Chloride , Neonicotinoids/analysis , Solid Phase Extraction
...