Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 3.400
1.
Sci Rep ; 14(1): 10602, 2024 05 08.
Article En | MEDLINE | ID: mdl-38719935

Although the application of magnetic compression anastomosis is becoming increasingly widespread, the magnets used in earlier studies were mostly in the shape of a whole ring. Hence, a deformable self-assembled magnetic anastomosis ring (DSAMAR) was designed in this study for gastrointestinal anastomosis. Furthermore, its feasibility was studied using a beagle model. The designed DSAMAR comprised 10 trapezoidal magnetic units. Twelve beagles were used as animal models, and DSAMARs were inserted into the stomach and colon through the mouth and anus, respectively, via endoscopy to achieve gastrocolic magnamosis. Surgical time, number of failed deformations, survival rate of the animals, and the time of magnet discharge were documented. A month later, specimens of the anastomosis were obtained and observed with the naked eye as well as microscopically. In the gastrocolic anastomosis of the 12 beagles, the procedure took 65-120 min. Although a deformation failure occurred during the operation in one of the beagles, it was successful after repositioning. The anastomosis was formed after the magnet fell off 12-18 days after the operation. Naked eye and microscopic observations revealed that the anastomotic specimens obtained 1 month later were well-formed, smooth, and flat. DSAMAR is thus feasible for gastrointestinal anastomosis under full endoscopy via the natural orifice.


Anastomosis, Surgical , Feasibility Studies , Animals , Dogs , Anastomosis, Surgical/methods , Stomach/surgery , Magnets , Magnetics , Natural Orifice Endoscopic Surgery/methods , Natural Orifice Endoscopic Surgery/instrumentation , Colon/surgery , Male
2.
Ulus Travma Acil Cerrahi Derg ; 30(5): 361-369, 2024 May.
Article En | MEDLINE | ID: mdl-38738679

Magnet ingestion in children can lead to serious complications, both acutely and chronically. This case report discusses the treatment approach for a case involving multiple magnet ingestions, which resulted in a jejuno-colonic fistula, segmental intestinal volvulus, hepa-tosteatosis, and renal calculus detected at a late stage. Additionally, we conducted a literature review to explore the characteristics of intestinal fistulas caused by magnet ingestion. A six-year-old girl was admitted to the Pediatric Gastroenterology Department pre-senting with intermittent abdominal pain, vomiting, and diarrhea persisting for two years. Initial differential diagnoses included celiac disease, cystic fibrosis, inflammatory bowel disease, and tuberculosis, yet the etiology remained elusive. The Pediatric Surgery team was consulted after a jejuno-colonic fistula was suspected based on magnetic resonance imaging findings. The physical examination revealed no signs of acute abdomen but showed mild abdominal distension. Subsequent upper gastrointestinal series and contrast enema graphy confirmed a jejuno-colonic fistula and segmental volvulus. The family later reported that the child had swallowed a magnet two years prior, and medical follow-up had stopped after the spontaneous expulsion of the magnets within one to two weeks. Surgical intervention was necessary to correct the volvulus and repair the large jejuno-colonic fistula. To identify relevant studies, we conducted a detailed literature search on magnet ingestion and gastrointestinal fistulas according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. We identified 44 articles encompassing 55 cases where symptoms did not manifest in the acute phase and acute abdomen was not observed. In 29 cases, the time of magnet ingestion was unknown. Among the 26 cases with a known ingestion time, the average duration until fistula detection was 22.8 days (range: 1-90 days). Fistula repairs were performed via laparotomy in 47 cases.


Intestinal Fistula , Humans , Female , Intestinal Fistula/etiology , Intestinal Fistula/surgery , Child , Foreign Bodies/complications , Foreign Bodies/surgery , Foreign Bodies/diagnostic imaging , Magnets/adverse effects , Malabsorption Syndromes/etiology , Malabsorption Syndromes/diagnosis , Jejunal Diseases/etiology , Jejunal Diseases/surgery , Jejunal Diseases/diagnosis , Intestinal Volvulus/surgery , Intestinal Volvulus/etiology , Intestinal Volvulus/diagnosis , Colonic Diseases/etiology , Colonic Diseases/surgery
3.
Transl Vis Sci Technol ; 13(5): 2, 2024 May 01.
Article En | MEDLINE | ID: mdl-38696181

Purpose: Currently, no solution exists to restore natural eyelid kinematics for patients with complete eyelid paralysis due to loss of function of both the levator palpebrae superioris and orbicularis oculi. These rare cases are prone to complications of chronic exposure keratopathy which may lead to corneal blindness. We hypothesized that magnetic force could be used to fully automate eyelid movement in these cases through the use of eyelid-attached magnets and a spectacle-mounted magnet driven by a programmable motor (motorized magnetic levator prosthesis [MMLP]). Methods: To test this hypothesis and establish proof of concept, we performed a finite element analysis (FEA) for a prototype MMLP to check the eyelid-opening force generated by the device and verified the results with experimental measurements in a volunteer with total bidirectional eyelid paralysis. The subject was then fitted with a prototype to check the performance of the device and its success. Results: With MMLP, eye opening was restored to near normal, and blinking was fully automated in close synchrony with the motor-driven polarity reversal, with full closure on the blink. The device was well tolerated, and the participant was pleased with the comfort and performance. Conclusions: FEA simulation results conformed to the experimentally observed trend, further supporting the proof of concept and design parameters. This is the first viable approach in human patients with proof of concept for complete reanimation of a bidirectionally paretic eyelid. Further study is warranted to refine the prototype and determine the feasibility and safety of prolonged use. Translational Relevance: This is first proof of concept for our device for total bidirectional eyelid paralysis.


Blinking , Eyelids , Proof of Concept Study , Humans , Blinking/physiology , Eyelids/physiopathology , Eyelid Diseases/physiopathology , Eyelid Diseases/therapy , Oculomotor Muscles/physiopathology , Finite Element Analysis , Biomechanical Phenomena , Prostheses and Implants , Prosthesis Design , Magnets , Male
4.
J Gastrointest Surg ; 28(5): 640-650, 2024 May.
Article En | MEDLINE | ID: mdl-38704201

BACKGROUND: Single-anastomosis metabolic/bariatric surgery procedures may lessen the incidence of anastomotic complications. This study aimed to evaluate the feasibility and safety of performing side-to-side duodenoileal (DI) bipartition using magnetic compression anastomosis (MCA). In addition, preliminary efficacy, quality of life (QoL), and distribution of food through the DI bipartition were evaluated. METHODS: Patients with a body mass index (BMI) of ≥35.0 to 50.0 kg/m2 underwent side-to-side DI bipartition with the magnet anastomosis system (MS) with sleeve gastrectomy (SG). By endoscopic positioning, a distal magnet (250 cm proximal to the ileocecal valve) and a proximal magnet (first part of the duodenum) were aligned with laparoscopic assistance to inaugurate MCA. An isotopic study assessed transit through the bipartition. RESULTS: Between March 14, 2022 to June 1, 2022, 10 patients (BMI of 44.2 ± 1.3 kg/m2) underwent side-to-side MS DI. In 9 of 10 patients, an SG was performed concurrently. The median operative time was 161.0 minutes (IQR, 108.0-236.0), and the median hospital stay was 3 days (IQR, 2-40). Paired magnets were expelled at a median of 43 days (IQR, 21-87). There was no device-related serious advanced event within 1 year. All anastomoses were patent with satisfactory diameters after magnet expulsion and at 1 year. Respective BMI, BMI reduction, and total weight loss were 28.9 ± 1.8 kg/m2, 15.2 ± 1.8 kg/m2, and 34.2% ± 4.1%, respectively. Of note, 70.0% of patients reported that they were very satisfied. The isotopic study found a median of 19.0% of the meal transited through the ileal loop. CONCLUSION: Side-to-side MCA DI bipartition with SG in adults with class II to III obesity was feasible, safe, and efficient with good QoL at 1-year follow-up. Moreover, 19% of ingested food passed directly into the ileum.


Anastomosis, Surgical , Duodenum , Feasibility Studies , Gastrectomy , Magnets , Humans , Gastrectomy/methods , Male , Female , Adult , Middle Aged , Duodenum/surgery , Anastomosis, Surgical/methods , Follow-Up Studies , Obesity, Morbid/surgery , Ileum/surgery , Quality of Life , Laparoscopy/methods , Body Mass Index , Operative Time , Bariatric Surgery/methods , Treatment Outcome , Gastrointestinal Transit
5.
World J Gastroenterol ; 30(16): 2272-2280, 2024 Apr 28.
Article En | MEDLINE | ID: mdl-38690021

BACKGROUND: The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula (TEF), but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model control. We designed a T-shaped magnet system to overcome these problems and verified its effectiveness via animal experiments. AIM: To investigate the effectiveness of a T-shaped magnet system for establishing a TEF model in beagle dogs. METHODS: Twelve beagles were randomly assigned to groups in which magnets of the T-shaped scheme (study group, n = 6) or normal magnets (control group, n = 6) were implanted into the trachea and esophagus separately under gastroscopy. Operation time, operation success rate, and accidental injury were recorded. After operation, the presence and timing of cough and the time of magnet shedding were observed. Dogs in the control group were euthanized after X-ray and gastroscopy to confirm establishment of TEFs after coughing, and gross specimens of TEFs were obtained. Dogs in the study group were euthanized after X-ray and gastroscopy 2 wk after surgery, and gross specimens were obtained. Fistula size was measured in all animals, and then harvested fistula specimens were examined by hematoxylin and eosin (HE) and Masson trichrome staining. RESULTS: The operation success rate was 100% for both groups. Operation time did not differ between the study group (5.25 min ± 1.29 min) and the control group (4.75 min ± 1.70 min; P = 0.331). No bleeding, perforation, or unplanned magnet attraction occurred in any animal during the operation. In the early postoperative period, all dogs ate freely and were generally in good condition. Dogs in the control group had severe cough after drinking water at 6-9 d after surgery. X-ray indicated that the magnets had entered the stomach, and gastroscopy showed TEF formation. Gross specimens of TEFs from the control group showed the formation of fistulas with a diameter of 4.94 mm ± 1.29 mm (range, 3.52-6.56 mm). HE and Masson trichrome staining showed scar tissue formation and hierarchical structural disorder at the fistulas. Dogs in the study group did not exhibit obvious coughing after surgery. X-ray examination 2 wk after surgery indicated fixed magnet positioning, and gastroscopy showed no change in magnet positioning. The magnets were removed using a snare under endoscopy, and TEF was observed. Gross specimens showed well-formed fistulas with a diameter of 6.11 mm ± 0.16 mm (range, 5.92-6.36 mm), which exceeded that in the control group (P < 0.001). Scar formation was observed on the internal surface of fistulas by HE and Masson trichrome staining, and the structure was more regular than that in the control group. CONCLUSION: Use of the modified T-shaped magnet scheme is safe and feasible for establishing TEF and can achieve a more stable and uniform fistula size compared with ordinary magnets. Most importantly, this model offers better controllability, which improves the flexibility of follow-up studies.


Disease Models, Animal , Magnets , Trachea , Tracheoesophageal Fistula , Animals , Dogs , Tracheoesophageal Fistula/surgery , Tracheoesophageal Fistula/pathology , Tracheoesophageal Fistula/etiology , Trachea/surgery , Trachea/pathology , Esophagus/surgery , Esophagus/pathology , Esophagus/diagnostic imaging , Gastroscopy/instrumentation , Gastroscopy/methods , Operative Time , Male , Magnetics/instrumentation , Equipment Design , Humans
6.
Sci Rep ; 14(1): 7879, 2024 04 03.
Article En | MEDLINE | ID: mdl-38570608

Achieving non-invasive spatiotemporal control over cellular functions, tissue organization, and behavior is a desirable aim for advanced therapies. Magnetic fields, due to their negligible interaction with biological matter, are promising for in vitro and in vivo applications, even in deep tissues. Particularly, the remote manipulation of paramagnetic (including superparamagnetic and ferromagnetic, all with a positive magnetic susceptibility) entities through magnetic instruments has emerged as a promising approach across various biological contexts. However, variations in the properties and descriptions of these instruments have led to a lack of reproducibility and comparability among studies. This article addresses the need for standardizing the characterization of magnetic instruments, with a specific focus on their ability to control the movement of paramagnetic objects within organisms. While it is well known that the force exerted on magnetic particles depends on the spatial variation (gradient) of the magnetic field, the magnitude of the field is often overlooked in the literature. Therefore, we comprehensively analyze and discuss both actors and propose a novel descriptor, termed 'effective gradient', which combines both dependencies. To illustrate the importance of both factors, we characterize different magnet systems and relate them to experiments involving superparamagnetic nanoparticles. This standardization effort aims to enhance the reproducibility and comparability of studies utilizing magnetic instruments for biological applications.


Magnetics , Nanoparticles , Reproducibility of Results , Magnets , Magnetic Fields
7.
ACS Appl Mater Interfaces ; 16(14): 17339-17346, 2024 Apr 10.
Article En | MEDLINE | ID: mdl-38531044

Living organisms inspire the design of microrobots, but their functionality is unmatched. Next-generation microrobots aim to leverage the sensing and communication abilities of organisms through magnetic hybridization, attaching magnetic particles to them for external control. However, the protocols used for magnetic hybridization are morphology specific and are not generalizable. We propose an alternative approach that leverages the principles of negative magnetostatics and magnetophoresis to control nonmagnetic organisms with external magnetic fields. To do this, we disperse model organisms in dispersions of Fe3O4 nanoparticles and expose them to either uniform or gradient magnetic fields. In uniform magnetic fields, living organisms align with the field due to external torque, while gradient magnetic fields generate a negative magnetophoretic force, pushing objects away from external magnets. The magnetic fields enable controlling the position and orientation of Caenorhabditis elegans larvae and flagellated bacteria through directional interactions and magnitude. This control is diminished in live spermatozoa and adult C. elegans due to stronger internal biological activity, i.e., force/torque. Our study presents a method for spatiotemporal organization of living organisms without requiring magnetic hybridization, opening the way for the development of controllable living microbiorobots.


Caenorhabditis elegans , Nanoparticles , Animals , Magnetics , Magnets , Magnetic Fields
8.
Sci Rep ; 14(1): 7068, 2024 03 25.
Article En | MEDLINE | ID: mdl-38528059

An affordable and reliable way of confirming the placement of nasogastric tube (NGT) at point-of-care is an unmet need. Using a novel algorithm and few sensors, we developed a low-cost magnet tracking device and showed its potential to localize the NGT preclinically. Here, we embark on a first-in-human trial. Six male and 4 female patients with NGT from the general ward of an urban hospital were recruited. We used the device to localize the NGT and compared that against chest X-ray (CXR). In 5 patients, with the sensors placed on the sternal angle, the trajectory of the NGT was reproduced by the tracking device. The tracked location of the NGT deviated from CXR by 0.55 to 1.63 cm, and a downward tracking range of 17 to 22 cm from the sternal angle was achieved. Placing the sensors on the xiphisternum, however, resulted in overt discordance between the device's localization and that on CXR. Short distance between the sternal angle and the xiphisternum, and lower body weight were observed in patients in whom tracking was feasible. Tracking was quick and well tolerated. No adverse event occurred. This device feasibly localized the NGT in 50% of patients when appropriately placed. Further refinement is anticipated.ClinicalTrials.gov identifier: NCT05204901.


Magnets , Point-of-Care Systems , Female , Humans , Male , Feasibility Studies , Intubation, Gastrointestinal , Radiography
9.
Bioorg Med Chem ; 102: 117672, 2024 Mar 15.
Article En | MEDLINE | ID: mdl-38461554

Small molecules that chemically induce proximity between two proteins have been widely used to precisely modulate protein levels, stability, and activity. Recently, several studies developed novel strategies that employ heterobifunctional molecules that co-opt shuttling proteins to control the spatial localization of a target protein, unlocking new potential within this domain. Together, these studies lay the groundwork for novel targeted protein relocalization modalities that can rewire the protein circuitry and interactome to influence biological outcomes.


Magnets , Proteins , Proteins/chemistry , Protein Binding
10.
Methods Enzymol ; 694: 1-49, 2024.
Article En | MEDLINE | ID: mdl-38492947

Magnetic tweezers have become popular with the outbreak of single molecule micromanipulation: catching a single molecule of DNA, RNA or a single protein and applying mechanical constrains using micron-size magnetic beads and magnets turn out to be easy. Various factors have made this possible: the fact that manufacturers have been preparing these beads to catch various biological entities-the ease of use provided by magnets which apply a force or a torque at a distance thus inside a flow cell-some chance: since the forces so generated are in the right range to stretch a single molecule. This is a little less true for torque. Finally, one feature which also appears very important is the simplicity of their calibration using Brownian motion. Here we start by describing magnetic tweezers used routinely in our laboratory where we have tried to develop a device as simple as possible so that the experimentalist can really focus on the biological aspect of the biomolecules that he/she is interested in. We discuss the implications of the various components and their important features. Next, we summarize what is easy to achieve and what is less easy. Then we refer to contributions by other groups who have brought valuable insights to improve magnetic tweezers.


Magnetics , Magnets , Magnetics/methods , DNA , Magnetic Fields , Motion , Optical Tweezers
11.
Eur Biophys J ; 53(3): 123-131, 2024 Apr.
Article En | MEDLINE | ID: mdl-38451329

We present a new phenomenon resulting from the interaction of magnetic beads with cancer cells in a laser trap formed on a slide containing a depression 16.5 mm in diameter and 0.78 mm of maximum depth. This phenomenon includes the apparent formation and expansion of a dark bubble that attracts and incinerates surrounding matter when it explodes, which leads to a plasma emitting intense radiation that has the appearance of a star on a microscopic scale. We have observed the star-like phenomenon for more than 4 years, and the intensity depends on the laser's power. Measuring the laser power of the dark bubble shows the entrapment of electromagnetic energy as it expands.


Magnets , Neoplasms , Lasers , Neoplasms/radiotherapy
12.
Lab Chip ; 24(7): 2122-2134, 2024 Mar 26.
Article En | MEDLINE | ID: mdl-38456199

Soft actuators capable of remote-controlled guidance and manipulation within complex constrained spaces hold great promise in various fields, especially in medical fields such as minimally invasive surgery. However, most current magnetic drive soft actuators only have the functions of position control and guidance, and it is still challenging to achieve more flexible operations on different targets within constrained spaces. Herein, we propose a multifunctional flexible magnetic drive gripper that can be steered within complex constrained spaces and operate on targets of various shapes. On the one hand, changing the internal pressure of the magnetic gripper can achieve functions such as suction or injection of liquid and transportation of targets with smooth surfaces. On the other hand, with the help of slit structures in the constrained environment, by simply changing the position and orientation of the permanent magnet in the external environment, the magnetic gripper can be controlled to clamp and release targets of linear, flaked, and polyhedral shapes. The full flexibility and multifunctionality of the magnetic gripper suggest new possibilities for precise remote control and object transportation in constrained spaces, so it could serve as a direct contact operation tool for hazardous drugs in enclosed spaces or a surgical tool in human body cavities.


Robotics , Humans , Equipment Design , Magnetics , Magnets , Magnetic Phenomena
14.
PLoS One ; 19(2): e0297806, 2024.
Article En | MEDLINE | ID: mdl-38335195

Immunomagnetic separation (IMS) techniques employing superparamagnetic particles can successfully isolate various components from mixtures. However, their utility can be limited for large-volume samples, viscous samples, or those containing a high density of particulate matter because of the need to generate high field gradients for particle recovery. Therefore, a new class of immunomagnetic particles was devised utilizing a single, macroscopic Pyrex spinbar conjugated with biorecognition elements to address these limitations. Advantages include an inherent capacity for effective mixing, an almost instantaneous recovery of the spinbar that can be performed without expensive equipment and with no loss of magnetic particles during processing, and reduced transfer of sample matrix. As a result, spinbars can provide an effective means for IMS with large-volume assays composed of complex matrices.


Immunomagnetic Separation , Magnets , Immunomagnetic Separation/methods , Magnetics , Magnetic Phenomena
15.
Int J Mol Sci ; 25(4)2024 Feb 09.
Article En | MEDLINE | ID: mdl-38396789

Pyridoxine (pyr) is a versatile molecule that forms part of the family of B vitamins. It is used to treat and prevent vitamin B6 deficiency and certain types of metabolic disorders. Moreover, the pyridoxine molecule has been investigated as a suitable ligand toward metal ions. Nevertheless, the study of the magnetic properties of metal complexes containing lanthanide(III) ions and this biomolecule is unexplored. We have synthesized and characterized a novel pyridoxine-based GdIII complex of formula [GdIII(pyr)2(H2O)4]Cl3 · 2 H2O (1) [pyr = pyridoxine]. 1 crystallizes in the triclinic system and space group Pi. In its crystal packing, cationic [Gd(pyr)2(H2O)4]3+ entities are connected through H-bonding interactions involving non-coordinating water molecules and chloride anions. In addition, Hirshfeld surfaces of 1 were calculated to further investigate their intermolecular interactions in the crystal lattice. Our investigation of the magnetic properties of 1, through ac magnetic susceptibility measurements, reveals the occurrence of a slow relaxation in magnetization in this mononuclear GdIII complex, indicating an unusual single-ion magnet (SIM) behavior for this pseudo-isotropic metal ion at very low temperatures. We also studied the relaxometric properties of 1, as a potential contrast agent for high-field magnetic resonance imaging (MRI), from solutions of 1 prepared in physiological serum (0.0-3.2 mM range) and measured at 3 T on a clinical MRI scanner. The values of relaxivity obtained for 1 are larger than those of some commercial MRI contrast agents based on mononuclear GdIII systems.


Gadolinium , Pyridoxine , Gadolinium/chemistry , Magnets , Magnetic Resonance Imaging/methods , Ions
16.
BMC Ophthalmol ; 24(1): 80, 2024 Feb 21.
Article En | MEDLINE | ID: mdl-38383362

PURPOSE: To compare the efficacy and efficiency of self-assembled intraocular rare earth magnet and forceps in removing intraocular foreign bodies(IOFBs) undergoing 25-gauge(G) pars plana vitrectomy. METHODS: A total of 30 patients with metallic IOFB underwent 25-G PPV were enrolled into this study. Self-assembled intraocular rare earth magnet were used in 15 patients(bar group), and forceps were used in 15 patients(forceps group). Success rate of removing IOFB, time taken to remove IOFB, incidence of IOFB slippage and fall, iatrogenic retinal damages were compared between the two groups. RESULTS: There was no significant difference in success rate of removing IOFBs between the groups(93.3% and 100%, P > 0.99). The median time taken of removing FB was significantly shorter in bar group than in forceps group(112 and 295 s, P = 0.001). None of the patients in bar group had IOFB slippage and fall, or related iatrogenic retinal damage in the process of removal. In forceps group, IOFB slippage and fall during removal were observed in 7 of 15(47.6%) patients, related iatrogenic retinal injuries were recorded in 6 of 15(40.0%) patients, both were significantly higher than bar group(P = 0.003 and P = 0.017, respectively). CONCLUSIONS: Compared with forceps, the assembled intraocular magnet can greatly reduce the possibility of IOFB slippage and fall, prevent related iatrogenic retinal damage, and shorten the time taken to remove IOFB. The assembled intraocular magnet can be an useful tool in removing metallic IOFBs in PPV.


Eye Foreign Bodies , Eye Injuries, Penetrating , Retinal Diseases , Humans , Vitrectomy , Magnets , Retrospective Studies , Eye Foreign Bodies/etiology , Eye Foreign Bodies/surgery , Surgical Instruments , Retinal Diseases/surgery , Iatrogenic Disease , Eye Injuries, Penetrating/etiology , Eye Injuries, Penetrating/surgery
17.
J Pediatr Gastroenterol Nutr ; 78(2): 374-380, 2024 Feb.
Article En | MEDLINE | ID: mdl-38374556

BACKGROUND: Ingestion of multiple high-powered neodymium rare-earth magnets poses a significant risk for gastrointestinal (GI) injury such as bowel perforation or ischemia. Given the rising incidence of rare earth magnetic ingestions and the corresponding increase in serious injuries in children, published guidelines recommend urgent endoscopic removal of all magnets within endoscopic reach in cases involving ingestions of two or more magnets. RESEARCH QUESTION: Do management patterns for multiple magnet ingestion align with current practice guidelines, and does hospital length of stay (LOS) differ based on the initial emergency department (ED) approach? METHODS: This is a retrospective chart review of consecutive patient encounters reported to the New Jersey Poison Information and Education System (NJPIES) between January 2021 and April 2022 involving multiple magnet ingestion. Potential cases were retrieved from the NJPIES TOXICALL® database, using substance codes relating to magnet or foreign body ingestion. Two-sample T tests were used to determine the statistical difference in the hospital LOS between the group of patients receiving early emergent esophagogastroduodenoscopy (EGD) versus those receiving expectant management on initial presentation. RESULTS: There was a difference in the average LOS of 2.7 days (p = 0.023) longer in the expectant management group with no medical complications in either group. Twenty-five percent or 2 out of 8 cases deviated from guidelines. CONCLUSION: The initial ED decision to pursue expectant management instead of attempting emergent EGD removal of magnets may result in prolonged hospitalization, increased risk for readmission, and delayed definitive removal of magnets due to nonprogression along the GI tract.


Foreign Bodies , Magnets , Child , Humans , Magnets/adverse effects , New Jersey/epidemiology , Retrospective Studies , Gastrointestinal Tract/injuries , Foreign Bodies/surgery , Foreign Bodies/complications , Eating
18.
Comput Biol Med ; 171: 108142, 2024 Mar.
Article En | MEDLINE | ID: mdl-38394805

As the alternative solution to the conventional guidewire, the magnetic robot can help interventionists perform percutaneous coronary intervention (PCI) because magnetic fields are transparent and safe for biological tissues. Despite extensive research on magnetic robots, the exploration of their deflection control for practical applications still requires further research. In this paper, a hierarchical analysis framework (HAF) is proposed to control the magnetic robot's deflection. Six deflection subpatterns are analyzed through HAF, incorporating statistical and regression analyses to establish governing equations of magnetic robots. The performance of the control equations is validated through precise control of the magnetic continuum robot (MCR) and magnet-tipped robot (MTR) in both uniform and gradient magnetic fields. Experimental results show that under the uniform magnetic field, the average root mean square error (RMSE) of governing equation of MCR is 0.08±0.05°, 0.41±0.34°, 1.47±0.49° and 1.07±0.66° for four-types horizontal deflection, 0.19±0.07mm and 0.16±0.10mm for two-types vertical deflection, respectively. Based on the governing equations, the MTR is able to precisely navigate to coronary arteries with various degrees of stenosis (30%, 52%, and 60%), and successfully pass through a series of rings, with an average error of 1.05 mm. The research successfully demonstrates the potential of HAF in creating robust and reliable governing equations for magnetic actuation in medical robotics, with significant implications for enhancing the precision and safety of PCI procedures.


Percutaneous Coronary Intervention , Robotics , Robotics/methods , Magnetic Fields , Magnets , Equipment Design
19.
Sci Rep ; 14(1): 4575, 2024 02 25.
Article En | MEDLINE | ID: mdl-38403623

Over the past 15 years, there has been a noticeable uptick in incidents involving children ingesting multiple magnetic foreign bodies which can cause injuries and gastrointestinal complications including death. The current study aimed to identify the prevalence, clinical presentation, and management of single or multiple magnet ingestions. A retrospective multi-central cross-sectional study was conducted to include all pediatric patients < 18 years presented to the emergency department with ingestion of single or multiple magnets and admitted across hospitals in Qatar, UAE, KSA, Tunisia, and Turkey between January 2011 and December 2021. Demographics, symptoms, management, and outcomes were analyzed. There were 189 magnet ingestions, of which 88 (46.6%) were multiple magnet ingestions. Most patients (55.6%) were male, and the median age was 3.9 (IQR 2-7) years. An abdominal X-ray was obtained in all cases. 119 (62%) patients were conservatively treated, 53 (28%) required surgical intervention and 17 (8.9%) underwent gastroscopy. None of the patients with single magnet ingestions experienced morbidity or severe outcomes. Multiple magnet ingestions led to significant morbidity including hospitalizations, perforations (44.3%), severe intestinal necrosis (19.3%), peritonitis (13.6%), severe abdominal infection (10.2%), and septic shock (4.5%). The rate of surgical intervention (59.1% vs. 1.0%) and gastroscopy (15.9% vs. 3.0%) was significantly higher in the multiple ingestion group compared to the single magnet ingestion group. No deaths were identified. A high risk of serious complications, including the need for surgery to remove the magnets and substantial morbidity may result from swallowing more than one magnet. Magnet safety requirements, public education, and improved legislation are urgently required.


Foreign Bodies , Magnets , Humans , Child , Male , Child, Preschool , Female , Magnets/adverse effects , Retrospective Studies , Cross-Sectional Studies , Foreign Bodies/epidemiology , Foreign Bodies/surgery , Eating
20.
BMJ Case Rep ; 17(1)2024 Jan 24.
Article En | MEDLINE | ID: mdl-38272527

Metallic foreign bodies (FBs) are a safety risk during MRI. Here, we describe a boy in early childhood with an unexpected ferromagnetic FB discovered during a research brain MRI. Safety precautions included written and oral safety screening checklists and visual check during a structured safety pause. During introduction to the scanner, he was lifted to look at the bore. Staff became aware of an object flying into the bore. The child reached for his ear, and a 5 mm diameter ball bearing was found in the bore. The child had no external injury. We have introduced a 0.1 T handheld magnet to check for metallic FBs not known to the parent. FBs are a common paediatric emergency department presentation, particularly in younger children or those with cognitive or behavioural problems. This case highlights the importance of safety screening in paediatric MRI scanning, along with its fallibility.


Foreign Bodies , Magnets , Male , Child , Humans , Child, Preschool , Magnets/adverse effects , Magnetic Resonance Imaging/adverse effects , Foreign Bodies/diagnostic imaging , Foreign Bodies/surgery , Emergency Service, Hospital , Neuroimaging
...