Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 783
1.
Acta Orthop Belg ; 90(1): 41-45, 2024 Mar.
Article En | MEDLINE | ID: mdl-38669647

Hip resurfacing arthroplasty (HRA) has been advocated as an attractive therapy for a younger, more demanding patient population with debilitating hip osteoarthritis. Controversies surrounding metal-on-metal (MoM) hip resurfacing have, however, led to a significant decline in the popularity of the HRA. Despite this, substantial evidence supports the use of specific implants in a selected group of patients. This is a continued retrospective analysis of a single surgeon series of the Birmingham Hip Resurfacing (BHR). Initial medium-term analysis was done in 2011 and published by Van der Bracht et al.13. This analysis includes a long-term follow-up of 7 to 12 years, including functional scoring (HHS, HOOS and UCLA activity score), metal ion evaluation and survival analysis. Failure was defined as revision for any cause. A total of 267 resurfacing procedures with the BHR were included in 247 patients. We had a mean follow-up of 8.3 years. Overall survival at ten years was 94.8%(97.2% for males and 90.1% for females). There was a statistically significant increase in mean HHS score at follow-up (56.03 - IQR 47-65 to 96.07 - IQR 96-100). Elevated metal ions were correlated with a statistically significant increase in the probability of complications. This cohort study further proved that hip resurfacing arthroplasty with the Birmingham Hip Resurfacing implant provides a good alternative to conventional total hip arthroplasty in young patients. There was a significant increase in functional scores at follow-up. There is further evidence of less favorable outcomes in female patients.


Arthroplasty, Replacement, Hip , Hip Prosthesis , Osteoarthritis, Hip , Humans , Female , Arthroplasty, Replacement, Hip/methods , Male , Middle Aged , Retrospective Studies , Follow-Up Studies , Osteoarthritis, Hip/surgery , Adult , Metal-on-Metal Joint Prostheses , Prosthesis Failure , Prosthesis Design , Aged , Reoperation/statistics & numerical data , Radiography/methods , Treatment Outcome
2.
Bone Joint J ; 106-B(3 Supple A): 51-58, 2024 Mar 01.
Article En | MEDLINE | ID: mdl-38423080

Aims: Elevated blood cobalt levels secondary to metal-on-metal (MoM) hip arthroplasties are a suggested risk factor for developing cardiovascular complications including cardiomyopathy. Clinical studies assessing patients with MoM hips using left ventricular ejection fraction (LVEF) have found conflicting evidence of cobalt-induced cardiomyopathy. Global longitudinal strain (GLS) is an echocardiography measurement known to be more sensitive than LVEF when diagnosing early cardiomyopathies. The extent of cardiovascular injury, as measured by GLS, in patients with elevated blood cobalt levels has not previously been examined. Methods: A total of 16 patients with documented blood cobalt ion levels above 13 µg/l (13 ppb, 221 nmol/l) were identified from a regional arthroplasty database. They were matched with eight patients awaiting hip arthroplasty. All patients underwent echocardiography, including GLS, investigating potential signs of cardiomyopathy. Results: Patients with MoM hip arthroplasties had a mean blood cobalt level of 29 µg/l (495 nmol/l) compared to 0.01 µg/l (0.2 nmol/l) in the control group. GLS readings were available for seven of the MoM cohort, and were significantly lower when compared with controls (-15.5% vs -18% (MoM vs control); p = 0.025)). Pearson correlation demonstrated that GLS significantly correlated with blood cobalt level (r = 0.8521; p < 0.001). However, there were no differences or correlations for other echocardiography measurements, including LVEF (64.3% vs 63.7% (MoM vs control); p = 0.845). Conclusion: This study supports the hypothesis that patients with elevated blood cobalt levels above 13 µg/l in the presence of a MoM hip implant may have impaired cardiac function compared to a control group of patients awaiting hip arthroplasty. It is the first study to use the more sensitive parameter of GLS to assess for any cardiac contractile dysfunction in patients with a MoM hip implant and a normal LVEF. Larger studies should be performed to determine the potential of GLS as a predictor of cardiac complications in patients with MoM arthroplasties.


Arthroplasty, Replacement, Hip , Arthroplasty, Replacement , Cardiomyopathies , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Humans , Cobalt/adverse effects , Stroke Volume , Metal-on-Metal Joint Prostheses/adverse effects , Ventricular Function, Left , Metals , Hip Prosthesis/adverse effects , Arthroplasty, Replacement, Hip/adverse effects , Chromium/adverse effects , Prosthesis Design
3.
Bone Joint J ; 106-B(3 Supple A): 44-50, 2024 Mar 01.
Article En | MEDLINE | ID: mdl-38423104

Aims: The first aim of this study was to evaluate whether preoperative renal function is associated with postoperative changes in whole blood levels of metal ions in patients who have undergone a Birmingham Hip Resurfacing (BHR) arthroplasty with a metal-on-metal bearing. The second aim was to evaluate whether exposure to increased cobalt (Co) and chromium (Cr) levels for ten years adversely affected renal function. Methods: As part of a multicentre, prospective post-approval study, whole blood samples were sent to a single specialized laboratory to determine Co and Cr levels, and the estimated glomerular filtration rate (eGFR). The study included patients with 117 unrevised unilateral BHRs. There were 36 females (31%). The mean age of the patients at the time of surgery of 51.3 years (SD 6.5), and they all had preoperative one-, four-, five-, and ten-year laboratory data. The mean follow-up was 10.1 years (SD 0.2). Results: Median Co levels at one year postoperatively increased significantly compared with the preoperative values, by a factor of 9.7, from 0.13 to 1.26 ppb (p < 0.001), and the median Cr levels increased significantly by a factor of 2.5, from 0.60 to 1.50 ppb (p < 0.001). Lower preoperative eGFRs were associated with significantly larger increases in Co at one year compared with the preoperative levels (ρ = -0.26; p = 0.005), but there was no relationship between preoperative eGFRs and changes in Cr at one year (ρ = -0.13; p = 0.153). Metal levels remained relatively constant with the passage of time, with a median ten-year value of 1.12 ppb for Co and 1.29 ppb for Cr. There was no significant relationship between the Co and Cr levels at ten-year follow-up and the change in eGFR from the preoperative level to that at ten years (ρ = -0.02; p = 0.827 for Co; ρ = -0.008; p = 0.933 for Cr). Conclusion: Although patients with lower preoperative eGFRs tended to have larger increases in Co levels at one year, increased metal levels for patients who underwent unilateral BHR did not adversely affect renal function during the first ten postoperative years.


Arthroplasty, Replacement, Hip , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Female , Humans , Middle Aged , Hip Prosthesis/adverse effects , Glomerular Filtration Rate , Prospective Studies , Metal-on-Metal Joint Prostheses/adverse effects , Prosthesis Design , Metals , Cobalt , Chromium
4.
J Biomed Mater Res B Appl Biomater ; 112(1): e35357, 2024 01.
Article En | MEDLINE | ID: mdl-38247242

To improve the wear resistance of articulating metallic joint endoprostheses, the surfaces can be coated with titanium niobium nitride (TiNbN). Under poor tribological conditions or malalignment, wear can occur on these implant surfaces in situ. This study investigated the biological response of human osteoblasts to wear particles generated from TiNbN-coated hip implants. Abrasive particles were generated in a hip simulator according to ISO 14242-1/-2 and extracted with Proteinase K. Particle characteristics were evaluated by electron microscopy and energy dispersive x-ray spectroscopy (EDS), inductively coupled plasma mass spectrometry (ICP-MS) and dynamic light scattering (DLS) measurements. Human osteoblasts were exposed to different particle dilutions (1:20, 1:50, and 1:100), and cell viability and gene expression levels of osteogenic markers and inflammatory mediators were analyzed after 4 and 7 days. Using ICP-MS, EDS, and DLS measurements, ~70% of the particles were identified as TiNbN, ranging from 39 to 94 nm. The particles exhibited a flat and subangular morphology. Exposure to particles did not influence cell viability and osteoblastic differentiation capacity. Protein levels of collagen type 1, osteoprotegerin, and receptor activator of nuclear factor κB ligand were almost unaffected. Moreover, the pro-inflammatory response via interleukins 6 and 8 was minor induced after particle contact. A high number of TiNbN wear particles only slightly affected osteoblasts' differentiation ability and inflammatory response compared to metallic particles. Nevertheless, further studies should investigate the role of these particles in peri-implant bone tissue, especially concerning other cell types.


Metal-on-Metal Joint Prostheses , Niobium , Titanium , Humans , Metals , Osteoblasts , Bone and Bones
5.
Int Orthop ; 48(3): 693-698, 2024 Mar.
Article En | MEDLINE | ID: mdl-37770674

BACKGROUND: Metal allergy remains a controversial topic in the orthopaedic community. It is not known if or to what degree metal sensitivity contributes to inflammatory soft tissue failures, unexplained residual pain, or clinical complications after total joint replacement with metal prostheses. METHODS: We investigated the efficacy of the lymphocyte transformation test (LTT) in predicting adverse outcomes in patients after receiving a metal joint replacement. Our study cohort consists of 135 metal-on-metal hip resurfacing arthroplasty cases performed between 2013 and 2015. All study patients had an LTT preoperatively. We retrospectively analyzed clinical outcomes and failures for our cohort. RESULTS: There was no difference in LTT reactivity between men and women. Of the 135 patients tested, 46 (34.1% of cohort) tested positive to at least one of the materials comprising their implant, and 78 patients (57.8%) had at least one reactive score to any component of the LTT. After a minimum follow-up of two years, we did not observe an allergic response to the implant in any patients. There were no failures requiring revision. We observed a 2.2% rate of moderate residual pain; no patients with residual pain tested positive for metal sensitivity. When patients with moderate-high LTT reactivity (30.4% of cohort) were compared to the remainder of the study group, there was no difference in HHS or UCLA activity score. There was no correlation between blood metal ion levels and LTT reactivity. CONCLUSION: We were unable to prove any predictive value of the LTT. We failed to identify hypersensitivity to metals in patients with metal-on-metal hip resurfacing arthroplasty.


Arthroplasty, Replacement, Hip , Hip Prosthesis , Hypersensitivity , Metal-on-Metal Joint Prostheses , Male , Humans , Female , Arthroplasty, Replacement, Hip/adverse effects , Prospective Studies , Retrospective Studies , Metal-on-Metal Joint Prostheses/adverse effects , Lymphocyte Activation , Metals/adverse effects , Hypersensitivity/epidemiology , Hypersensitivity/etiology , Pain/etiology , Hip Prosthesis/adverse effects
6.
Hip Int ; 34(2): 215-220, 2024 Mar.
Article En | MEDLINE | ID: mdl-37545332

INTRODUCTION: Metal-on-metal (MoM) total hip arthroplasty (THA) may cause adverse reactions to metal debris (ARMD). ARMD causing femoral vessel compression with serious complications has been described in case reports, but the rate of compression by ARMD is not known. This study aims to investigate the rate, and quantify the severity, of femoral vessel compression in MoM hips with ARMD lesions. METHODS: Patients under surveillance for MoM THA investigated with MRI were studied. In patients with confirmed ARMD, femoral artery (FA) and vein (FV) diameters were measured at the point of maximal compression and compared to contralateral vessels. The primary outcome measure was presence or absence of compression. Cases were then classified by compression ratios. Secondary outcome measures were rates of deep vein thrombosis, revision surgery and time to ARMD from index procedure. RESULTS: MRI scans for 436 patients with MoM THA were screened. Of these, 211/436 (48.4%) showed evidence of ARMD. Measurements were obtained on 133/211 (63.0%) patients. The FV was compressed in 102/133 (76.7%) and FA in 58/133 (43.6%), while 31/133 (23.3%) patients had no compression. In FVs, 42 demonstrated mild compression, 39 moderate and 21 severe. In FAs, none were severely compressed, 6 were moderate and 52 showed mild compression. There were 3 DVT cases, 2 in patients with moderate FV compression and 1 in patients without FV compression. Revision rates were highest in patients with severe FV compression (14/21, 66.7%). The mean time for MRI-diagnosed ARMD from index procedure was 8 years and 1 month (range 11 months-14.5 years). CONCLUSIONS: Extra-luminal compression of the femoral vessels was found in >75% of patients with ARMD. Although it is not clear whether revision for femoral vessel compression is required, quantification of FV compression may be useful for surgeons and radiologists considering revision for ARMD.


Arthroplasty, Replacement, Hip , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Humans , Arthroplasty, Replacement, Hip/adverse effects , Hip Prosthesis/adverse effects , Metal-on-Metal Joint Prostheses/adverse effects , Metals/adverse effects , Femur , Reoperation , Prosthesis Design , Prosthesis Failure , Retrospective Studies
7.
J Arthroplasty ; 39(3): 801-805, 2024 Mar.
Article En | MEDLINE | ID: mdl-37648100

BACKGROUND: Synovial leukocyte count analysis is an important tool in the diagnosis of PJI. However, results can be poor if metallosis is present. The issue of metallosis was established for some rotating hinge knee arthroplasty designs. METHODS: This was a retrospective single-center analysis that included 108 patients who had a single-design metal-on-metal rotating hinge knee arthroplasty who underwent revision surgery and had prior synovial fluid analysis performed. The diagnostic accuracy of leukocyte count and the percentage of polymorphonuclear neutrophiles (% PMN) were investigated. RESULTS: Patients who had a PJI had a higher median leukocyte count and % PMN compared to aseptic revisions (7,905/µL (interquartile range (IQR) 2,419 to 37,400) and 85% (IQR 70.3 to 93.8) versus 450 (IQR 167 to 1,215) and 46% (IQR 28.5 to 67.4%), P < .001). The respective areas under the curves were 0.916 (95% confidence interval 0.862 to 0.970) for leukocyte count and 0.821 (95% confidence interval 0.739 to 0.902) for % PMN. We calculated an optimal cut-off value of 1,200 leukocytes/µL (Sensitivity 94.5%/specificity 75.5%) and 63% PMN (Sensitivity 85.5%/specificity 73.6%) to define PJI. Established thresholds were less sensitive, but more specific. The "infection likely" scenario of the European Bone and Joint Infection Society (EBJIS) definition was closest to the calculated thresholds. CONCLUSION: Currently used thresholds for leukocyte cell count and %PMN to define PJI were less sensitive and specific in the diagnosis of PJI in metal-on-metal RHK knees. Surgeons must consider lower cut-off values when evaluating such implants for PJI.


Arthritis, Infectious , Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Metal-on-Metal Joint Prostheses , Prosthesis-Related Infections , Humans , Neutrophils , Arthroplasty, Replacement, Knee/adverse effects , Retrospective Studies , Synovial Fluid , Prosthesis-Related Infections/diagnosis , Leukocyte Count , Arthritis, Infectious/diagnosis , Sensitivity and Specificity , Biomarkers
8.
Int Orthop ; 48(3): 719-727, 2024 Mar.
Article En | MEDLINE | ID: mdl-37907694

PURPOSE: Revision of failed large head metal-on-metal (MoM) total hip arthroplasty (THA) is a challenging procedure particularly to reconstruct acetabular bone defect due to osteolysis and to achieve hip stability due to soft tissue damages, both potentially caused by adverse reaction to metal debris (ARMD). This study aimed to evaluate the outcome of dual mobility cup (DMC) constructs in revision THA for failed large head MoM bearings with a special attention to the occurrence of dislocation or re-revision. METHODS: Between 2015 and 2019, 57 patients (64 THAs, 41 men, mean age = 65 ± 10 years) underwent revision for MoM THA with the use of DMC were prospectively included in our total joint registry. Mean time to revision was 11 ± 2.5 years. The causes for revision were adverse reaction to metal debris (ARMD) in 49 THAs (76%), painful hip with elevated blood cobalt-chromium ions in seven (11%), and acetabular aseptic loosening in eight (13%). The revision was complete in 22 THAs (34%) and acetabular only in 42 (66%). Clinical and radiographic outcomes, complications, and re-revisions were evaluated at most recent follow-up. RESULTS: At mean follow-up of six ± 1.5 years, the pre- to postoperative Harris Hip Score improved from 74 ± 19 to 92 ± 4 (p = 0.004). Complications occurred in 11 cases (17%): five dislocations (8%), three periprosthetic infections (5%), two aseptic loosening of the acetabular component (3%), and two periprosthetic fractures (3%). Re-revision was required in six cases (9%). CONCLUSION: The use of DMC is a reliable option to prevent instability and ensure a stable acetabular reconstruction in revision THA for failed large head MoM bearings. However, dislocation after revision remains a concern, particularly in cases of severe soft tissue damage related to ARMD.


Arthroplasty, Replacement, Hip , Hip Prosthesis , Joint Dislocations , Metal-on-Metal Joint Prostheses , Male , Humans , Middle Aged , Aged , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis/adverse effects , Metal-on-Metal Joint Prostheses/adverse effects , Treatment Outcome , Retrospective Studies , Metals/adverse effects , Reoperation/methods , Joint Dislocations/etiology , Prosthesis Design , Prosthesis Failure , Follow-Up Studies
10.
JBJS Case Connect ; 13(4)2023 Oct 01.
Article En | MEDLINE | ID: mdl-38096339

CASE: There is an increasing emphasis on adverse reactions to metal debris around prosthetic hip implants. We present a case report of a patient with increasing pain around a previous total hip arthroplasty and magnetic resonance imaging findings consistent with a pseudotumor. Serum metal ion levels were not elevated and initial biopsy findings inconclusive. The patient was diagnosed with an extraskeletal chondrosarcoma after revision total hip arthroplasty and subsequently underwent external hemipelvectomy with negative margins. CONCLUSION: This report highlights the importance of remaining vigilant for malignant sarcomas presenting as pseudotumors around hip replacements, particularly in the absence of abnormal metal ion levels or definitive biopsy results.


Arthroplasty, Replacement, Hip , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Sarcoma , Humans , Arthroplasty, Replacement, Hip/adverse effects , Cobalt , Hip Prosthesis/adverse effects , Metal-on-Metal Joint Prostheses/adverse effects , Metals/adverse effects , Prosthesis Design , Sarcoma/diagnosis , Sarcoma/etiology , Sarcoma/surgery , Diagnosis, Differential
11.
Musculoskelet Surg ; 107(4): 439-446, 2023 Dec.
Article En | MEDLINE | ID: mdl-37285004

PURPOSE: The aim of this retrospective study was to evaluate the medium-term clinical and radiographic results of current generation metal-on-metal resurfacing prostheses performed through anterolateral approach. MATERIALS AND METHODS: Fifty-seven hips in 52 patients underwent resurfacing arthroplasty. Two patients died from unrelated causes, leaving 55 hips in 35 males (3 bilateral) and 15 females (2 bilateral), with a mean age at surgery of 56.2 years (range, 27-70 years). Clinical and radiographic assessment was carried out preoperatively and at follow-up in all the survived cases. The cumulative survival rate was determined according to the method of Kaplan-Meier. RESULTS: At a mean follow-up of 5.2 years (range, 1.8-9.1 years), 2 HRs of the same female patient were revised because of early loosening of the acetabular component. Deep venous thrombosis and transient femoral nerve palsy occurred both in 1 case. No specific complications of HR were observed. Average Harris hip score improved significantly from 59.8 points (range, 30.4-90.6) preoperatively to 93.7 points (range, 53-100) at the latest examination. Neck narrowing showed an average of 3.27%, but it never exceeded 10%. Nonprogressive acetabular radiolucencies and osteolysis were detected both in 2 hips. A high rate of patients (32, 60.4%) developed heterotopic ossifications, although low-grade in most cases (27, 84.4%). The cumulative survival rate at 9.1 years with revision for any reason as the end point was 93.0%. CONCLUSIONS: The early clinical and radiographic results of modern metal-on-metal hip resurfacing performed through an anterolateral approach are promising, but longer-term follow-up studies are necessary.


Arthroplasty, Replacement, Hip , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Male , Humans , Female , Adult , Middle Aged , Aged , Arthroplasty, Replacement, Hip/methods , Treatment Outcome , Retrospective Studies , Metal-on-Metal Joint Prostheses/adverse effects , Follow-Up Studies , Reoperation , Hip Joint/diagnostic imaging , Hip Joint/surgery , Prosthesis Failure
12.
Orthopadie (Heidelb) ; 52(6): 504-508, 2023 Jun.
Article En | MEDLINE | ID: mdl-37171637

BACKGROUND: The history of total hip arthroplasty dates back to the first half of the twentieth century. Data on hip endoprostheses implanted during the 1960s and 1970s suggest widely varying survival rates of the prosthesis. CASE: A case of a patient who underwent total hip arthroplasty in 1972 using a Sivash prosthesis, developed in 1956 in the former Soviet Union, is presented in this article. The prosthesis has remained unrevised in the patient's body for 50 years and he continues to be widely free of implant-related symptoms. Despite the constrained metal-on-metal design of the implant, which can lead to adverse reactions to metal debris, no elevated systemic metal ion levels were detected. CONCLUSION: The likelihood of encountering patients with prosthesis survival beyond 50 years is still rare. Nevertheless, changing demographics and the steadily improving designs and materials of hip endoprostheses may likely result in such cases.


Arthroplasty, Replacement, Hip , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Male , Humans , Arthroplasty, Replacement, Hip/adverse effects , Hip Prosthesis/adverse effects , Metal-on-Metal Joint Prostheses/adverse effects , Prosthesis Design , Metals
13.
Eur J Orthop Surg Traumatol ; 33(7): 3089-3097, 2023 Oct.
Article En | MEDLINE | ID: mdl-37017738

PURPOSE: Growing number of hip arthroplasty in Poland performed with the use of metaphyseal stems results from the decreasing age of patients qualified for procedures and is consistent with the corresponding trends in European countries. To this day, a significant population functions after undergoing hip replacement using metal-on-metal implant. This study was aimed at the assessment of the variability of the oxidative system, as well as the concentrations of chromium and cobalt ions in serum and blood and their potential impact on postoperative clinical status. MATERIAL AND METHODS: The analysis included 58 men. The first group-operated using J&J DePuy ASR metal-on-metal implant with metaphyseal stem ProximaTm. Second group-operated using K-Implant SPIRON® femoral neck prosthesis in full ceramic articulation. Selected parameters of oxidative stress and the antioxidant system as well as the concentration of metal ions in blood were determined twice. Each patient underwent two clinical evaluations using acclaimed physical examination scale systems. RESULTS: In the first group, significantly higher concentrations of Cr (p = 0.028) and Co (p = 0.002) were demonstrated compared to the group of femoral neck arthroplasty. The mean concentrations of Cr and Co, 10.45 and 9.26 µg/l, respectively, were higher in patients operated bilaterally. In the ASR group, greater pain intensity in the operated hip and higher indicators of oxidative stress were found. CONCLUSIONS: Metal-on-metal articulation of the hip significantly increases the concentration of Cr and Co in blood, induces oxidative stress and modifies function of the antioxidant system and generates greater pain in the operated hip.


Arthroplasty, Replacement, Hip , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Male , Humans , Hip Prosthesis/adverse effects , Femur Neck , Antioxidants , Metal-on-Metal Joint Prostheses/adverse effects , Prosthesis Design , Metals , Arthroplasty, Replacement, Hip/adverse effects , Cobalt , Chromium , Ceramics , Ions , Oxidative Stress
14.
Arch Orthop Trauma Surg ; 143(9): 5967-5976, 2023 Sep.
Article En | MEDLINE | ID: mdl-36802238

BACKGROUND: Pseudotumors and muscle atrophy have been associated with metal-on-metal (MoM) resurfacing hip arthroplasty (RHA). We aimed to investigate the influence of the anterolateral (AntLat) and the posterior (Post) surgical approach on the location, grade and prevalence of pseudotumors and muscle atrophy in MoM RHA. PATIENTS AND METHODS: Forty-nine patients were randomized to MoM RHA by the AntLat (n = 25) or the Post (n = 24) approach at Aarhus University Hospital. Patients underwent metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) scans for investigation of location, grade and prevalence of pseudotumors and muscle atrophy. Plain radiographs, metal-ions concentrations and clinical outcome scores were evaluated to compare outcomes of the surgical approaches. RESULTS: MRI-detected pseudotumors were seen in 7 of 18 patients (39%) in the AntLat group and in 12 of 22 patients (55%) in the Post group (p = 0.33). Pseudotumors were mainly located anterolaterally to the hip joint in the AntLat group and postero-lateral to the hip joint in the Post group. Higher grades of muscle atrophy of the caudal part of the gluteus medius and minimus (p < 0.004) were seen in the AntLat group, and higher grades of muscle atrophy of the small external rotators were seen in the Post group (p < 0.001). The AntLat group had higher anteversion angles of mean 15.3° (range 6.1-7.5) versus mean 11.5° (range 4.9-22.5) in the Post group (p = 0.02). Metal-ion concentrations and clinical outcome scores were similar between groups (p > 0.08). CONCLUSION: Muscle atrophy and pseudotumor location after MoM RHA follow the surgical approach used for implantation. This knowledge may help differentiate between "normal postoperative appearance" and "MoM disease."


Arthroplasty, Replacement, Hip , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Humans , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Metals , Magnetic Resonance Imaging/methods , Muscular Atrophy/diagnostic imaging , Muscular Atrophy/etiology , Prosthesis Design , Cobalt
15.
Orthopadie (Heidelb) ; 52(3): 206-213, 2023 Mar.
Article En | MEDLINE | ID: mdl-36820850

Metal-on-metal (MoM) bearing hip arthroplasty saw increasing utilization and peaked in the 1990s and early 2000s. Although the linear and volumetric wear rate for a MoM bearings was lower than its polyethylene counterpart, metal ion particles were found to be approximately 10â€¯× smaller and 500â€¯× higher in quantity compared to polyethylene wear debris. Research into these articulations have demonstrated their relationship to the formation of lymphocyte-mediated adverse local tissue reactions. The work-up for metal particle-associated conditions (metallosis) includes a thorough patient history and physical examination, blood laboratory studies for metal ion concentrations, and advanced imaging studies including magnetic resonance imaging (MRI). The treatment of metallosis and adverse local tissue reactions ranges from close serial observation to extensive debridement and full revision of arthroplasty components, when indicated.


Arthroplasty, Replacement, Hip , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Humans , Arthroplasty, Replacement, Hip/adverse effects , Hip Prosthesis/adverse effects , Metal-on-Metal Joint Prostheses/adverse effects , Metals , Polyethylene
16.
Arch Orthop Trauma Surg ; 143(7): 4501-4510, 2023 Jul.
Article En | MEDLINE | ID: mdl-36443614

INTRODUCTION: Few studies have examined the survival rates of total hip arthroplasty (THA) with the same femoral stem, and the predictive factors leading to the revision of stemmed metal-on-metal (MoM) THA remain unknown. We determined the long-term survival rate of stemmed MoM THA compared with that of metal-on-polyethylene (MoP) bearing THA, the effect of head size and cup placement angle on revision rate, and predictors of revision. MATERIALS AND METHODS: A total of 130 hips in 110 patients who underwent primary THA by the same surgeon were included. M2a-RingLoc with a metal-on-polyethylene bearing (group P, 53 hips), M2a-Taper with MoM bearing (group T, 44 hips), and M2a-Magnum with MoM bearing (group M, 33 hips) were used. The mean age at surgery was 63.1 ± 9.5 years, and the mean postoperative follow-up duration was 133.7 ± 39.1 months. Whole blood metal ion concentrations were measured preoperatively and postoperatively, and magnetic resonance imaging was performed to identify aseptic local tissue reactions (ALTRs). Kaplan-Meier survivorship analysis and multiple logistic regression analysis were performed. RESULTS: The THA survival rate up to the maximum postoperative follow-up period was 96.2% at 173 months, 46.6% at 179 months, and 47.8% at 145 months in groups P, T, and M, respectively, with revision as the endpoint. The stemmed MoM THA recorded a very low survival rate (p < 0.001). The ALTR rates were 70.5% and 63.6% in groups T and M, respectively. The risk factor for revision was the use of MoM bearing, and there was no difference in the results based on the head size in group M. Cobalt levels continued to increase postoperatively, although they were not accurate predictors of revision. CONCLUSIONS: Stemmed MoM THA has a very low survival rate and should be used with caution. It is important to monitor the patient's symptoms and perform appropriate imaging to ensure timely revision.


Arthroplasty, Replacement, Hip , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Humans , Arthroplasty, Replacement, Hip/methods , Survival Rate , Reoperation/methods , Risk Factors , Metals , Polyethylene , Prosthesis Design , Prosthesis Failure
17.
Hip Int ; 33(5): 872-879, 2023 Sep.
Article En | MEDLINE | ID: mdl-36314413

BACKGROUND: Elevated serum chrome (sCr) and cobalt (sCo) concentrations are associated with local tissue adverse reactions to metal debris following metal-on-metal hip resurfacing (MoM-HR). Serum metal ions <2 µg/l are probably of little clinical relevance and a pragmatic "safe" threshold <5 µg/l has been suggested.The primary aim of this study was to evaluate if a careful selection of patients combined with optimal implant positioning could eliminate cases with "unsafe" serum metal ion levels. A secondary aim was to study the association between different risk factors and having Co and/or Cr levels >5 µg/l. PATIENTS AND METHODS: This is a retrospective, single-institution cohort study of 410 consecutive patients operated on with a Birmingham Hip Resurfacing (BHR) implant between 2001 and 2014. 288 of these had a unilateral MoM-HR, pelvic and true lateral radiographs, and a related sCo and sCr sample, and were included in the final analysis. They were allocated to either a presumed "optimal group" consisting of only men aged <60 years old, with femoral head component >48 mm diameter, and with a cup positioned within Lewinnek's safe zones, or a "suboptimal group" consisting of the remaining patients. Fisher's exact test and multiple logistic regression analyses were performed. RESULTS: In the optimal group 48% (47/97) had serum metal ions >2 µg/l and 8% (8/97) >5 µg/l compared to 61% (116/191) and 18% (34/191) in the suboptimal group, p = 0.059 and p = 0.034 respectively. Acetabular cups with an anteversion <5 degrees had the highest odds ratio, 6.5 (95% CI, 3.0-14.3), of having sCo and sCr concentrations exceeding 5 µg/l. CONCLUSIONS: A well oriented BHR acetabular component in a presumably "optimal" patient reduces the risk of having elevated serum metal ions but does not eliminate it. Insufficient cup anteversion seems to be the strongest associated factor of elevated serum metals.


Arthroplasty, Replacement, Hip , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Male , Humans , Middle Aged , Cobalt , Arthroplasty, Replacement, Hip/adverse effects , Patient Selection , Cohort Studies , Retrospective Studies , Metal-on-Metal Joint Prostheses/adverse effects , Chromium , Metals , Hip Prosthesis/adverse effects , Ions , Prosthesis Design
18.
Orthopedics ; 46(1): e45-e51, 2023.
Article En | MEDLINE | ID: mdl-36314875

Total hip arthroplasty (THA) in young patients has varying results, and some reports show inferior results when compared with those of older patients. This study evaluated the outcomes of contemporary uncemented THA in patients 45 years or younger. This was a retrospective review from 2003 to 2015 at an academic institution. Three hundred one uncemented THAs in 232 patients 45 years or younger were evaluated. All patients had a minimum follow-up of 5 years. Ninety-day complications, survivorship free of revision, and dislocations were evaluated. Mean age was 35.7 years, 43.1% of patients were women, and mean follow-up was 9.3 years. Ninety-day complications included 26 emergency department visits, 11 readmissions, 3 revisions, and 3 dislocations. The rate of 10-year survivorship free of revision was 85.5%, and the rate of 10-year survivorship free of aseptic revision was 87.7%. Excluding metal-on-metal (MOM) THAs, 10-year aseptic survivorship was 93.3%. The most common reasons for revision were adverse local tissue reaction after MOM THA (16 hips) and periprosthetic joint infection (6 hips). In a multivariable logistic regression model, sickle cell disease (SCD) and conversion THA were associated with 90-day readmissions. Both MOM THA and SCD were associated with revision (P<.05). Patients who are 45 years or younger undergoing THA (excluding MOM articulation) had a rate of 10-year survival free of aseptic revision of 93.3%. At 9.3 years' mean follow-up, THA in young patients was associated with low revision rates with acceptable risk of prosthetic joint infection and dislocation. Patients with SCD are at increased risk for early readmission and revision at latest follow-up. [Orthopedics. 2023;46(1):e45-e51.].


Arthroplasty, Replacement, Hip , Hip Prosthesis , Joint Dislocations , Metal-on-Metal Joint Prostheses , Humans , Female , Adult , Male , Arthroplasty, Replacement, Hip/adverse effects , Hip Joint/surgery , Hip Prosthesis/adverse effects , Prosthesis Failure , Risk Factors , Metal-on-Metal Joint Prostheses/adverse effects , Reoperation , Metals , Joint Dislocations/surgery , Retrospective Studies , Prosthesis Design
19.
Orthop Traumatol Surg Res ; 109(1): 103472, 2023 02.
Article En | MEDLINE | ID: mdl-36336293

In 2005 and 2011, we reported results for a comparative study of two types of 28-mm bearing (metal-on-metal (MoM) and ceramic-on-polyethylene (CoP) in active patients with respectively 5 and 12 years' follow-up. The present report is an update at a mean 20 years' follow-up, addressing 2 issues: (1) implant survival at a mean 20 years; and (2) long-term complications with the metal-on-metal bearing. Twenty-eight millimeters MoM bearings show good survival at 20 years in young active subjects. Two groups of cementless hip prostheses were compared: Metasul™ 28mm MoM versus 28mm CoP. The MoM group comprised 30 patients (39 hips), with a mean age of 40±6.7 years [range, 22.6-49 years], and the CoP group comprised 32 patients (39 hips), with a mean age of 40.5±8.7 years [range, 15-50 years]. The groups were matched in 2005 for age, activity level and preoperative Harris score. At a mean 20±5.3 years' follow-up [range, 5-23 years], in the MoM group 2 hips (5%) showed limited non-progressive acetabular osteolysis, not requiring revision surgery; in the CoP group, there were 21 revision procedures (54%), including 15 for polyethylene wear. In the MoM group, the median total blood cobalt concentration was 1.03g/L [range, 0.3-3.5] and the median chromium concentration was 1.07g/L [range, 0.3-3.2]. Twenty-year all-cause survival was 100% in the MoM group, and 46% (95% CI, 37-59%) in the CoP group (p<0.0001). At long-term follow-up, MoM implants showed better survival than CoP implants in a young active population. Level of evidence: III, matched case series.


Arthroplasty, Replacement, Hip , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Humans , Adult , Middle Aged , Arthroplasty, Replacement, Hip/methods , Polyethylene , Retrospective Studies , Metals , Reoperation/methods , Prosthesis Design , Ceramics
20.
Hip Int ; 33(5): 864-871, 2023 Sep.
Article En | MEDLINE | ID: mdl-35848136

BACKGROUND: Studies investigating changes in blood metal ion levels during the second decade of the implant lifetime in MoM hip resurfacing patients are scarce. METHODS: Patients implanted with either Birmingham Hip Resurfacing (BHR) or Articular Surface Replacement (ASR) hip resurfacings with >10 years follow-up and repeated blood metal ion measurements were identified at 2 large specialist European arthroplasty centres. After excluding patients with initial metal ion levels >7 ppb, the proportion of patients with an increase in blood metal ion levels above previously validated implant-specific thresholds (cobalt 2.15 ppb for unilateral implants, cobalt or chromium 5.5 ppb for bilateral) was assessed. RESULTS: We included 2743 blood metal ion measurements from 457 BHR patients (555 hips) and 216 ASR patients (263 hips). Of patients with initial metal ion levels below implant specific thresholds, increases in cobalt or chromium level, respectively, to above these thresholds during the second decade were seen as follows: unilateral BHR (cobalt = 15.6%), unilateral ASR (cobalt = 13.8%), bilateral BHR (cobalt = 8.2%, chromium = 11.8%), bilateral ASR (cobalt = 8.5%, chromium = 4.3%). Measurement-to-measurement changes exceeding +2.15 ppb or +5.5 ppb were, however, uncommon during the second decade. Subgroup results with small diameter (<50 mm) implants were similar. CONCLUSIONS: We recommend less frequent blood metal ion measurements are needed (every 3 to 5 years) for hip resurfacing patients if initial values were below 7ppb.


Arthroplasty, Replacement, Hip , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Humans , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Follow-Up Studies , Prosthesis Design , Metal-on-Metal Joint Prostheses/adverse effects , Hip Prosthesis/adverse effects , Metals , Chromium , Cobalt , Prosthesis Failure
...