Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
BMC Pharmacol Toxicol ; 18(1): 73, 2017 11 16.
Artículo en Inglés | MEDLINE | ID: mdl-29145890

RESUMEN

BACKGROUND: Metolazone is a diuretic, saluretic and antihypertensive chemical compound from the quinazoline category that possesses medicinal features similar to those of other thiazide diuretic drugs. However, the pharmacokinetics of metolazone in the Chinese population has rarely been studied. This study aimed to examine the pharmacokinetic characteristics, safety characteristic, and tolerability of metolazone in healthy Chinese subjects after single and multiple doses taken orally as well as the effects that food and gender have on oral metolazone pharmacokinetic parameters. METHODS: An open-label, randomized, and single- and multiple-dosing investigation was performed in healthy Chinese subjects. The investigation included 3 study groups: the 0.5 mg, 1 mg and 2 mg dose groups were the single-dose study groups in the first stage. Eligible volunteers were randomly and orally administered a single 0.5 mg, 1 mg, or 2 mg metolazone tablet. The 0.5 mg dose group was also part of the multiple-dose study group, and the 1 mg dose group was the food-effect study group in the second stage. Human plasma samples were gathered pre-dosing and up to 48 h after dosing. The human plasma sample concentration of metolazone was quantified using a validated liquid chromatography tandem mass spectrometry method. Pharmacokinetic data were calculated by a noncompartmental analysis method using WinNonlin version 6.4. Tolerability was evaluated based on adverse events, medical examination, 12-lead ECG, and other clinical laboratory exams. RESULTS: Thirty eligible subjects (15 men and 15 women) were registered in our investigation and completed all of the study stages. The AUC and Cmax showed dose proportionality after a single dose based on the linear-regression analysis. A comparison of the pharmacokinetic data revealed that the differences between the male and female groups were not statistically significant. The tmax of metolazone was increased by approximately 100% in the fed condition. Metolazone was well tolerated at the tested dose, and no adverse effects were observed. CONCLUSIONS: Single dosing with 0.5 mg, 1 mg, or 2 mg metolazone yielded linear plasma pharmacokinetic properties in healthy Chinese subjects. Multiple oral doses of metolazone did not display significantly different distributions or elimination characteristics from those observed for a single dose. Gender factors did not appear to influence the pharmacokinetic parameter variation of metolazone. The tmax of metolazone increased in the fed condition. Metolazone was well tolerated at the tested dose in this study. TRIAL REGISTRATION: This investigation is retrospectively registered at chictr.org.cn (ChiCTR-IIR-17012929, October 09 2017).


Asunto(s)
Antihipertensivos/farmacocinética , Diuréticos/farmacocinética , Metolazona/farmacocinética , Administración Oral , Adolescente , Adulto , Antihipertensivos/administración & dosificación , Antihipertensivos/sangre , Área Bajo la Curva , Pueblo Asiatico , Diuréticos/administración & dosificación , Diuréticos/sangre , Esquema de Medicación , Femenino , Interacciones Alimento-Droga , Semivida , Voluntarios Sanos , Humanos , Masculino , Metolazona/administración & dosificación , Metolazona/sangre , Comprimidos , Adulto Joven
2.
Eur J Mass Spectrom (Chichester) ; 23(5): 305-312, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29028382

RESUMEN

Combination of metolazone (0.5 mg) and valsartan (80 mg) has been verified as a promising therapy treatment for hypertension. In order to facilitate to pharmacokinetic research, it needs a method for the simultaneously determination of metolazone and valsartan in biological samples. However, there are no relative reports so far. In order to facilitate to pharmacokinetic research, an on-line solid phase extraction coupled with liquid chromatography-tandem mass spectrometry method for the simultaneous determination of metolazone and valsartan in beagle dog plasma was developed and validated in this study. An on-line solid phase extraction column Retain PEP Javelin (10 mm × 2.1 mm) was used to remove impurities in plasma samples. The metolazone, valsartan and internal standard (losartan) were separated on a Poroshell 120 SB-C18 column (4.6 mm × 50 mm × 2.7 µm) with a gradient elution procedure. Acidified acetonitrile/water mixture was used as a mobile phase. The selected multiple-reaction monitoring mode in positive ion was performed and the parent to the product transitions m/z 366/259, m/z 436.2/291 and m/z 423.4/207 were used to measure the metolazone, valsartan and losartan. The method was linear over the range of 0.1-100 ng/mL and 1-1000 ng/mL for metolazone and valsartan, respectively. This method was validated in terms of specificity, linearity, sensitivity, precision, accuracy, matrix effect, and stability and then successfully applied to pharmacokinetic studies of the metolazone and valsartan combination tablets in beagle dogs.


Asunto(s)
Cromatografía Liquida/métodos , Metolazona/sangre , Extracción en Fase Sólida/métodos , Espectrometría de Masas en Tándem/métodos , Valsartán/sangre , Animales , Perros , Modelos Lineales , Masculino , Metolazona/química , Metolazona/farmacocinética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Valsartán/química , Valsartán/farmacocinética
3.
J Chromatogr Sci ; 53(9): 1520-7, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25947361

RESUMEN

For the first time, we developed and validated a highly sensitive, selective and rapid HPLC-ESI-MS-MS method for simultaneous quantification of metolazone (MET), losartan (LOS) and its metabolite losartan carboxylic acid (LCA) in rat plasma. After solid-phase extraction, the analytes and internal standard (irbesartan) were extracted from 100 µL plasma sample on an Agilent Poroshell 120, EC-C18 (50 × 4.6 mm, i.d., 2.7 µm) column using 5 µL injection volume with a total run time of 3 min. Acidified methanol/water mixture was used as a mobile phase. The parent → product ion transitions for MET (m/z 366.0 → 258.9), LOS (m/z 423.2 → 207.0), LCA (m/z 437.0 → 235.1) and IS (m/z 429.2 → 207.0) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring and positive ion mode. The method was found to be linear in the range of 0.05-250 for MET, 2-3,000 for LOS and 4-3,500 ng/mL for LCA. The method was validated with respect to selectivity, linearity, accuracy, precision, recovery and stability according to accepted regulatory guidelines. The described method was successfully applied to preclinical pharmacokinetic studies of analytes after an oral administration of mixture of MET (1 mg/kg) and LOS (10 mg/kg) in rats.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Losartán/sangre , Losartán/farmacocinética , Metolazona/sangre , Metolazona/farmacocinética , Espectrometría de Masas en Tándem/métodos , Animales , Modelos Lineales , Losartán/química , Masculino , Metolazona/química , Ratas , Ratas Wistar , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Masa por Ionización de Electrospray/métodos
4.
Luminescence ; 29(5): 462-70, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23996979

RESUMEN

A new, specific and sensitive reversed-phase high-performance liquid chromatography method was developed for the simultaneous determination of metolazone (MET) and losartan potassium (LOS). Good chromatographic separation was achieved within 6.0 min on a 150 × 4.6 mm i.d., 5 µm Waters, Ireland and ProDIGY 5 ODS 3 100 A column. A mobile phase containing a mixture of methanol and 0.02 M phosphate buffer (65:35, v/v) at pH 3.0 was used. The analysis was performed at a flow rate of 1 mL/min with fluorescence detection at 410 nm after excitation at 230 nm. Aspirin (ASP) was used as an internal standard. The proposed method was rectilinear over 2.0-40.0 (MET) and 40.0-800.0 ng/mL (LOS), with limits of detection of 0.22 and 4.52 ng/mL and limits of quantification of 0.68 and 13.70 ng/mL for MET and LOS, respectively. The method was successfully applied for the simultaneous analysis of the studied drugs in their laboratory-prepared mixtures, single tablets and co-formulated tablets. Moreover, the method was applied to an in vitro drug release (dissolution) test. The method was further extended to the determination of LOS in spiked human plasma. Statistical evaluation and comparison of data obtained using the proposed and comparison methods revealed no significant difference between the two methods in addition to good accuracy and precision for the proposed method.


Asunto(s)
Antihipertensivos/sangre , Cromatografía Líquida de Alta Presión/métodos , Diuréticos/sangre , Fluorometría/métodos , Losartán/sangre , Metolazona/sangre , Cromatografía Líquida de Alta Presión/instrumentación , Combinación de Medicamentos , Humanos , Comprimidos/análisis
5.
Biomed Chromatogr ; 25(10): 1138-43, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21387350

RESUMEN

A simple, rapid and accurate liquid chromatography-tandem mass spectrometry method has been developed. After a liquid-liquid extraction procedure, samples were chromatographed on an Agilent TC-C(18) (150 × 4.6 mm, 5 µm) column using an isocratic elution mobile phase composed of methanol and distilled water (70:30, v/v) at a flow rate of 0.5 mL/min. After single-dose administration of 0.5, 1 and 2 mg metolazone, the t(1/2) values were 6.6 ± 2.8, 7.9 ± 1.2 and 7.6 ± 1.9 h, respectively. The pharmacokinetic parameters of multiple doses (1 mg metolazone) were as follows: t(1/2) was 8.9 ± 1.0 h; C(max) was 22.4 ± 5.0 ng/mL; and AUC(0-48) was 156.8 ± 31.6 ng h/mL.


Asunto(s)
Cromatografía Liquida/métodos , Metolazona/sangre , Espectrometría de Masas en Tándem/métodos , Adulto , Área Bajo la Curva , Estabilidad de Medicamentos , Femenino , Humanos , Análisis de los Mínimos Cuadrados , Masculino , Metanol/química , Metolazona/administración & dosificación , Metolazona/farmacocinética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Artículo en Inglés | MEDLINE | ID: mdl-16908225

RESUMEN

A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometric method is described for the determination of metolazone in human blood. Metolazone was extracted from blood using ethyl acetate and separated on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. The mobile phase consisting of a mixture of acetonitrile, 10 mmol/l ammonium acetate and formic acid (60:40:0.1, v/v/v) was delivered at a flow rate of 0.5 ml/min. Electrospray ionization (ESI) source was operated in positive ion mode. Selected reaction monitoring (SRM) mode using the transitions of m/z 366-->m/z 259 and m/z 321-->m/z 275 were used to quantify metolazone and the lorazepam (internal standard), respectively. The linearity was obtained over the concentration range of 0.5-500 ng/ml for metolazone and the lower limit of quantitation (LLOQ) was 0.5 ng/ml. For each level of QC samples, inter- and intra-run precision was less than 8.07 and 3.56% (relative standard deviation (RSD)), respectively, and the bias was within +/-4.0%. This method was successfully applied to the pharmacokinetic study of metolazone formulation after oral administration to humans.


Asunto(s)
Cromatografía Liquida/métodos , Metolazona/sangre , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masas en Tándem/métodos , Estabilidad de Medicamentos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
J Chromatogr B Biomed Appl ; 653(2): 171-6, 1994 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-8205244

RESUMEN

A novel solid-phase on-line elution HPLC method employing fluorescence detection to measure metolazone in plasma and whole blood has been developed. The method is sensitive and selective for metolazone and linear over a dynamic range of 1-50 ng/ml with a sample requirement of 250 microliters. The limit of quantitation for the method is 1 ng/ml and combined intra- and inter-day accuracy and precision had an error and coefficient of variation of 2.9 and 5.5%, respectively.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Metolazona/sangre , Humanos , Fallo Renal Crónico/sangre , Fallo Renal Crónico/tratamiento farmacológico , Masculino , Metolazona/farmacocinética , Metolazona/uso terapéutico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Fluorescencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA