Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 1.772
1.
Sci Data ; 11(1): 494, 2024 May 14.
Article En | MEDLINE | ID: mdl-38744868

The standard of care for brain tumors is maximal safe surgical resection. Neuronavigation augments the surgeon's ability to achieve this but loses validity as surgery progresses due to brain shift. Moreover, gliomas are often indistinguishable from surrounding healthy brain tissue. Intraoperative magnetic resonance imaging (iMRI) and ultrasound (iUS) help visualize the tumor and brain shift. iUS is faster and easier to incorporate into surgical workflows but offers a lower contrast between tumorous and healthy tissues than iMRI. With the success of data-hungry Artificial Intelligence algorithms in medical image analysis, the benefits of sharing well-curated data cannot be overstated. To this end, we provide the largest publicly available MRI and iUS database of surgically treated brain tumors, including gliomas (n = 92), metastases (n = 11), and others (n = 11). This collection contains 369 preoperative MRI series, 320 3D iUS series, 301 iMRI series, and 356 segmentations collected from 114 consecutive patients at a single institution. This database is expected to help brain shift and image analysis research and neurosurgical training in interpreting iUS and iMRI.


Brain Neoplasms , Databases, Factual , Magnetic Resonance Imaging , Multimodal Imaging , Humans , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/surgery , Brain/diagnostic imaging , Brain/surgery , Glioma/diagnostic imaging , Glioma/surgery , Ultrasonography , Neuronavigation/methods
2.
Adv Tech Stand Neurosurg ; 49: 19-34, 2024.
Article En | MEDLINE | ID: mdl-38700678

Neurosurgical procedures are some of the most complex procedures in medicine and since the advent of the field, planning, performing, and learning them has challenged the neurosurgeon. Virtual reality (VR) and augmented reality (AR) are making these challenges more manageable. VR refers to a virtual digital environment that can be experienced usually through use of stereoscopic glasses and controllers. AR, on the other hand, fuses the natural environment with virtual images, such as superimposing a preoperative MRI image on to the surgical field [1]. They initially were used primarily as neuronavigational tools but soon their potential in other areas of surgery, such as planning, education, and assessment, was noted and explored. Through this chapter, we outline the history and evolution of these two technologies over the past few decades, describe the current state of the technology and its uses, and postulate future directions for research and implementation.


Augmented Reality , Neurosurgical Procedures , Virtual Reality , Humans , Neurosurgical Procedures/methods , Child , Neurosurgery/methods , Pediatrics/methods , Neuronavigation/methods
3.
J Clin Neurosci ; 123: 203-208, 2024 May.
Article En | MEDLINE | ID: mdl-38608532

OBJECTIVE: Neuronavigation is common technology used by skull base teams when performing endoscopic endonasal surgery. A common practice of MRI imagining is to obtain 3D isotopic gadolinium enhanced T1W magnetisation prepared rapid gradient echo (MPRAGE) sequences. These are prone to distortion when undertaken on 3 T magnets. The aim of this project is to compare the in vivo accuracy of MRI sequences between current and new high resolution 3D sequences. The goal is to determine if geometric distortion significantly affects neuronavigation accuracy. METHODS: Patients were scanned with a 3D T1 MPRAGE sequence, 3D T1 SPACE sequence and a CT stereotactic localisation. Following general anaesthesia, patients were registered on the Stealth Station (Medtronic, USA) using a side mount emitter for Electromagnetic navigation. A variety of surgically relevant anatomical landmarks in the sagittal and coronal plane were selected with real and virtual data points measured. RESULTS: A total of 10 patients agreed be enrolled in the study with datapoints collected during surgery. The distance between real and virtual datapoints trended to be lower in SPACE sequences compared to MPRAGE. Paired t test did not demonstrate a significant difference. CONCLUSION: We have demonstrated that navigational accuracy is not significantly affected by the type of MRI sequence selected and that current corrective algorithms are sufficient. Navigational accuracy is affected by many factors, with registration error likely playing the most significant role. Further research involving real time imaging such as endoscopic ultrasound may hopefully address this potential error.


Magnetic Resonance Imaging , Neuronavigation , Skull Base , Humans , Neuronavigation/methods , Magnetic Resonance Imaging/methods , Skull Base/surgery , Skull Base/diagnostic imaging , Male , Female , Middle Aged , Adult , Imaging, Three-Dimensional/methods , Neuroendoscopy/methods , Aged
4.
Clin Neurol Neurosurg ; 240: 108269, 2024 May.
Article En | MEDLINE | ID: mdl-38593567

OBJECTIVE: The V3 segment of the vertebral artery (V3-VA) is at risk during diverse approaches to the craniovertebral junction. Our objective is to present a system of anatomic and topographic landmarks to identify the V3-VA during the paramedian suboccipital approach (PMSOA) with the help of minimal or basic tools. MATERIAL AND METHODS: The first was a retrospective analysis of the angiotomography (CTA) of 50 patients over 18-years old, and 9 anatomical dissections. A series of lines were defined between the different bony landmarks. Within this lines the risk area of the vertebral artery (RAsV3-VA) and the risk point of the vertebral artery (RPsV3-VA) were defined. The second stage was a prospective study, where the previously defined measurements were carried out by using neuronavigation in 10 patients (20 sides) operated with the PMSO approach in order to confirm the presence of the V3 segment in the RAsV3-VA and RPsV3-VA. RESULTS: In the first stage, the V3 segment was found in the middle third of the X line in 96,6% of the cases. The distance between the inion and the UCP (percentile 5) was 20 mm and to the LCP (percentile 95) was 40 mm. In the range between the UCP and the LCP, in the middle third of the inion-mastoid line (RAsV3-VA), we found 90% of the V3-VA. The measurements taken during the second stage revealed that the artery was in the middle third of the X line in 97% of the cases. 85% of the patients presented the total of the V3s-VA on the RAsV3-VA and in 85% there was a direct relationship with the V3 segment and the RPV3s-VA. CONCLUSION: We propose an easy-to-implement system to delimit the risk area of the V3-VA during the PMSOA. We believe that these landmarks provide a practical, reliable, costless and useful tool that could decrease the risk of lesion of the V3-VA during this approach without the need of using.


Vertebral Artery , Humans , Vertebral Artery/anatomy & histology , Vertebral Artery/diagnostic imaging , Male , Female , Middle Aged , Adult , Retrospective Studies , Aged , Prospective Studies , Adolescent , Young Adult , Neurosurgical Procedures/methods , Neuronavigation/methods
5.
No Shinkei Geka ; 52(2): 248-253, 2024 Mar.
Article Ja | MEDLINE | ID: mdl-38514113

Recently, three-dimensional(3D)holograms from mixed-reality(MR)devices have become available in the medical field. 3D holographic images can provide immersive and intuitive information that has been reported to be very useful for preoperative simulations. Compared with conventional 3D images on a two-dimensional(2D)monitor, 3D holograms offer a higher level of realism, allowing observation of the images anytime and anywhere if the MR device is operational. Even during surgery, surgeons can check realistic 3D holograms in front of them, above the surgical field, without having to turn their heads toward a 2D monitor on the wall. 3D holograms can also be used for neuronavigation if the hologram is tracked to the patient's real head. This method can be defined as 3D augmented reality(AR)navigation, which shows a hologram of a target, such as a tumor or aneurysm, inside the head and brain. In the future, interventions using these techniques with 3D holograms from MR devices are expected to evolve and develop new types of treatments for endoscopic surgery or fluoroscopy-guided endovascular surgery.


Augmented Reality , Holography , Surgery, Computer-Assisted , Humans , Surgery, Computer-Assisted/methods , Neuronavigation/methods , Imaging, Three-Dimensional/methods , Holography/methods
6.
BMC Surg ; 24(1): 86, 2024 Mar 12.
Article En | MEDLINE | ID: mdl-38475783

OBJECTIVE: To compare neuronavigation-assisted intracerebral hematoma puncture and drainage with neuroendoscopic hematoma removal for treatment of hypertensive cerebral hemorrhage. METHOD: Ninety-one patients with hypertensive cerebral hemorrhage admitted to our neurosurgery department from June 2022 to May 2023 were selected: 47 patients who underwent endoscopic hematoma removal with the aid of neuronavigation in observation Group A and 44 who underwent intracerebral hematoma puncture and drainage in control Group B. The duration of surgery, intraoperative bleeding, hematoma clearance rate, pre- and postoperative GCS score, National Institutes of Health Stroke Scale (NIHSS) score, mRS score and postoperative complications were compared between the two groups. RESULTS: The duration of surgery, intraoperative bleeding and hematoma clearance were significantly lower in Group B than in Group A (p < 0.05). Conversely, no significant differences in the preoperative, 7-day postoperative, 14-day postoperative or 1-month postoperative GCS or NIHSS scores or the posthealing mRS score were observed between Groups A and B. However, the incidence of postoperative complications was significantly greater in Group B than in Group A (p < 0.05), with the most significant difference in incidence of intracranial infection (p < 0.05). CONCLUSION: Both neuronavigation-assisted intracerebral hematoma puncture and drainage and neuroendoscopic hematoma removal are effective at improving the outcome of patients with hypertensive cerebral hemorrhage. The disadvantage of neuronavigation is that the incidence of complications is significantly greater than that of other methods; postoperative care and prevention of complications should be strengthened in clinical practice.


Intracranial Hemorrhage, Hypertensive , Neuroendoscopy , Humans , Neuronavigation/methods , Intracranial Hemorrhage, Hypertensive/surgery , Paracentesis , Treatment Outcome , Drainage/methods , Neuroendoscopy/methods , Hematoma/surgery , Postoperative Complications/surgery , Retrospective Studies
7.
World Neurosurg ; 185: e1207-e1215, 2024 May.
Article En | MEDLINE | ID: mdl-38519017

BACKGROUND: Gliomas adjacent to the corticospinal tract (CST) should be carefully resected to preserve motor function while achieving maximal surgical resection. Modern high-field intraoperative magnetic resonance imaging (iMRI) enables precise visualization of the residual tumor and intraoperative tractography. We prospectively evaluated the extent of resection and distance between the tumor resection cavity and CST using 3-T iMRI combined with motor evoked potentials (MEP) in glioma surgery. METHODS: Participants comprised patients who underwent surgery for solitary supratentorial glioma located within 10 mm of the CST. All cases underwent surgery using neuronavigation with overlaid CST under MEP monitoring. The correlation between distance from CST and transcortical MEP amplitude was calculated using Spearman rank correlation. RESULTS: Among the 63 patients who underwent surgery, 27 patients were enrolled in the study. Gross total resections were achieved in 26 of the 27 cases. Volumetric analysis showed the extent of resection was 98.6%. Motor function was stable or improved in 24 patients (Stable/Improved group) and deteriorated in 3 patients (Deteriorated group). All patients in the Deteriorated group showed motor deficit before surgery. Mean intraoperative minimal distance was significantly longer in the Stable/Improved group (7.3 mm) than in the Deteriorated group (1.1 mm; P < 0.05). MEP amplitude correlated with minimal distance between the resection cavity and CST (R = 0.64). CONCLUSIONS: Resection of gliomas adjacent to CST with a navigation system using 3-T iMRI could result in an ultimate EOR >98%. The combination of intraoperative tractography and MEP contributes to maximal removal of motor-eloquent gliomas.


Evoked Potentials, Motor , Glioma , Magnetic Resonance Imaging , Neuronavigation , Pyramidal Tracts , Humans , Pyramidal Tracts/diagnostic imaging , Pyramidal Tracts/surgery , Glioma/surgery , Glioma/diagnostic imaging , Male , Female , Middle Aged , Adult , Magnetic Resonance Imaging/methods , Aged , Evoked Potentials, Motor/physiology , Neuronavigation/methods , Brain Neoplasms/surgery , Brain Neoplasms/diagnostic imaging , Neurosurgical Procedures/methods , Prospective Studies , Young Adult , Monitoring, Intraoperative/methods , Intraoperative Neurophysiological Monitoring/methods , Supratentorial Neoplasms/surgery , Supratentorial Neoplasms/diagnostic imaging
8.
World Neurosurg ; 185: 245, 2024 May.
Article En | MEDLINE | ID: mdl-38382753

Arteriovenous malformations (AVMs) are complex vascular lesions that can pose significant risk for spontaneous hemorrhage, seizures, and symptoms related to ischemia and venous hypertension.1 Microsurgical management of AVMs requires a deep understanding of the surrounding anatomy and precise identification of the lesion characteristics. We demonstrate the use of augmented reality in the localization of arterial feeders and draining veins in relation to bordering normal structures (Video 1). A 66-year-old man presented with several episodes of severe right frontal headaches. Magnetic resonance imaging revealed an AVM along the right frontal pole. Subsequent computed tomography angiography demonstrated arterial supply from the right anterior cerebral artery with venous drainage to the superior sagittal sinus. Due to the size, noneloquent location, and superficial pattern of venous drainage, the patient elected to proceed with microsurgery. A virtual planning platform was used in preparation for surgery. Augmented reality integrated with neuronavigation was used during microsurgical resection. Postoperative angiography showed complete resection of the AVM. The patient was discharged home on postoperative day 3 with no complications. He remains neurologically well at 4 months of follow-up.


Augmented Reality , Intracranial Arteriovenous Malformations , Microsurgery , Humans , Male , Aged , Microsurgery/methods , Intracranial Arteriovenous Malformations/surgery , Intracranial Arteriovenous Malformations/diagnostic imaging , Neuronavigation/methods , Surgery, Computer-Assisted/methods , Neurosurgical Procedures/methods , Frontal Lobe/surgery , Frontal Lobe/diagnostic imaging , Frontal Lobe/blood supply
9.
World Neurosurg ; 185: 171-180, 2024 May.
Article En | MEDLINE | ID: mdl-38401754

Brainstem surgery is more difficult and riskier than surgeries in other parts of the brain due to the high density of critical tracts and cranial nerves nuclei in this region. For this reason, some safe entry zones into the brainstem have been described. The main purpose of this article is to bring on the agenda the significance of the intrinsic structures of the safe entry zones to the brainstem. Having detailed information about anatomic localization of these sensitive structures is important to predict and avoid possible surgical complications. In order to better understand this complex anatomy, we schematically drew the axial sections of the brainstem showing the intrinsic structures at the level of 9 safe entry zones that we used, taking into account basic neuroanatomy books and atlases. Some illustrations are also supported with intraoperative pictures to provide better surgical orientation. The second purpose is to remind surgeons of clinical syndromes that may occur in case of surgical injury to these delicate structures. Advanced techniques such as tractography, neuronavigation, and neuromonitorization should be used in brainstem surgery, but detailed neuroanatomic knowledge about safe entry zones and a meticulous surgery are more important. The axial brainstem sections we have drawn can help young neurosurgeons better understand this complex anatomy.


Brain Stem , Neurosurgical Procedures , Humans , Brain Stem/anatomy & histology , Brain Stem/surgery , Neurosurgical Procedures/methods , Neuronavigation/methods , Clinical Relevance
10.
J Neurosci Methods ; 404: 110062, 2024 04.
Article En | MEDLINE | ID: mdl-38309312

BACKGROUND: In clinical routine, navigated transcranial magnetic stimulation (nTMS) is usually applied down to 25 mm. Yet, besides clinical experience and mathematical models, the penetration depth remains unclear. This study aims to investigate the maximum cortical stimulation depth of nTMS in patients with meningioma above the primary motor cortex, causing a displacement of the primary motor cortex away from the skull. NEW METHOD: nTMS stimulation data was reviewed regarding the maximum depth of stimulations eliciting motor-evoked potentials (MEPs). Additionally, electric field values and stimulation intensity were analyzed. RESULTS: Out of a consecutive cohort of 17 meningioma cases, 3 cases of meningioma located in motor-eloquent regions of the upper extremity and 3 cases of the lower extremity were analyzed after fulfilling all inclusion criteria. Regarding the upper extremity motor representations, the MEP could be elicited at a stimulation depth of up to 44 mm, with an electric field of 69 V/m. These results were found in 1 case with the maximum potential distance to the cortex being higher than the maximum stimulation depth eliciting MEPs. For the lower extremities, a maximum depth of 40 mm was recorded (electric field 64 V/m). COMPARISON WITH EXISTING METHODS: None available CONCLUSIONS: The effect of nTMS is not limited to superficial cortical stimulation alone. Depending on electric-field intensity and focality, nTMS stimulation can be applied at a depth of 44 mm. In all cases, electric field strength was comparable and no superficial cortex with comparable electric field strength was observed to elicit MEPs.


Brain Neoplasms , Meningeal Neoplasms , Meningioma , Motor Cortex , Humans , Transcranial Magnetic Stimulation/methods , Motor Cortex/physiology , Brain Neoplasms/surgery , Brain Mapping/methods , Neuronavigation/methods
11.
J Med Syst ; 48(1): 25, 2024 Feb 23.
Article En | MEDLINE | ID: mdl-38393660

Precise neurosurgical guidance is critical for successful brain surgeries and plays a vital role in all phases of image-guided neurosurgery (IGN). Neuronavigation software enables real-time tracking of surgical tools, ensuring their presentation with high precision in relation to a virtual patient model. Therefore, this work focuses on the development of a novel multimodal IGN system, leveraging deep learning and explainable AI to enhance brain tumor surgery outcomes. The study establishes the clinical and technical requirements of the system for brain tumor surgeries. NeuroIGN adopts a modular architecture, including brain tumor segmentation, patient registration, and explainable output prediction, and integrates open-source packages into an interactive neuronavigational display. The NeuroIGN system components underwent validation and evaluation in both laboratory and simulated operating room (OR) settings. Experimental results demonstrated its accuracy in tumor segmentation and the success of ExplainAI in increasing the trust of medical professionals in deep learning. The proposed system was successfully assembled and set up within 11 min in a pre-clinical OR setting with a tracking accuracy of 0.5 (± 0.1) mm. NeuroIGN was also evaluated as highly useful, with a high frame rate (19 FPS) and real-time ultrasound imaging capabilities. In conclusion, this paper describes not only the development of an open-source multimodal IGN system but also demonstrates the innovative application of deep learning and explainable AI algorithms in enhancing neuronavigation for brain tumor surgeries. By seamlessly integrating pre- and intra-operative patient image data with cutting-edge interventional devices, our experiments underscore the potential for deep learning models to improve the surgical treatment of brain tumors and long-term post-operative outcomes.


Brain Neoplasms , Surgery, Computer-Assisted , Humans , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/surgery , Brain Neoplasms/pathology , Neuronavigation/methods , Surgery, Computer-Assisted/methods , Neurosurgical Procedures/methods , Ultrasonography , Magnetic Resonance Imaging/methods
12.
Medicina (Kaunas) ; 60(2)2024 Feb 16.
Article En | MEDLINE | ID: mdl-38399622

Background and Objectives: To investigate the role of augmented reality (AR) in skull base (SB) neurosurgery. Materials and Methods: Utilizing PRISMA methodology, PubMed and Scopus databases were explored to extract data related to AR integration in SB surgery. Results: The majority of 19 included studies (42.1%) were conducted in the United States, with a focus on the last five years (77.8%). Categorization included phantom skull models (31.2%, n = 6), human cadavers (15.8%, n = 3), or human patients (52.6%, n = 10). Microscopic surgery was the predominant modality in 10 studies (52.6%). Of the 19 studies, surgical modality was specified in 18, with microscopic surgery being predominant (52.6%). Most studies used only CT as the data source (n = 9; 47.4%), and optical tracking was the prevalent tracking modality (n = 9; 47.3%). The Target Registration Error (TRE) spanned from 0.55 to 10.62 mm. Conclusion: Despite variations in Target Registration Error (TRE) values, the studies highlighted successful outcomes and minimal complications. Challenges, such as device practicality and data security, were acknowledged, but the application of low-cost AR devices suggests broader feasibility.


Augmented Reality , Neurosurgery , Surgery, Computer-Assisted , Humans , Surgery, Computer-Assisted/methods , Neuronavigation/methods , Skull Base/surgery
13.
World Neurosurg ; 185: 285-289, 2024 May.
Article En | MEDLINE | ID: mdl-38403019

BACKGROUND: Sacroiliac joint (SIJ) fusion, to treat back pain caused by SIJ dysfunction, can employ open or minimally invasive surgery (MIS) techniques and either cylindrical (screw-shaped) or triangular (wedge-shaped) implants. Fusion nonunion sometimes explains recurrent SIJ pain following fusion and occasionally requires hardware revision. MIS revision minimizes patient pain, infection, and disability, but due to the triangular implant size and form factor, implant removal can present challenges for MIS access during the explantation and achieving good bony purchase for reinstrumentation. Here, we report a prone single-position lateral MIS/posterior mini-open procedure for triangular-implant SIJ fusion revision. METHODS: The patient is a 72-year-old female who underwent right SIJ fusion for lower back and leg pain sustained after a fall 2 years prior but experienced recurrent pain over the subsequent 2 years, with imaging findings of right SIJ peri-hardware lucencies and diagnostic injections confirming persistent right-sided sacroiliitis. RESULTS: The patient underwent hardware removal using the lateral MIS incision with table-mounted tubular access and image-guided navigation to maintain exposure, plus simultaneous reinstrumentation using a navigated S2-alar-iliac screw and iliac bolt construct with connecting rod through the posterior mini-open incision made for the navigation reference frame spinous process clamp. CONCLUSIONS: The use of navigation and MIS access can significantly decrease the complexity of lateral hardware removal, and mini-open navigated screw-and-rod constructs offer reinstrumentation options accessible to surgeons unfamiliar with specialized posterior SIJ systems.


Device Removal , Minimally Invasive Surgical Procedures , Reoperation , Sacroiliac Joint , Spinal Fusion , Humans , Female , Sacroiliac Joint/surgery , Sacroiliac Joint/diagnostic imaging , Aged , Reoperation/methods , Spinal Fusion/methods , Spinal Fusion/instrumentation , Device Removal/methods , Minimally Invasive Surgical Procedures/methods , Neuronavigation/methods , Low Back Pain/surgery , Low Back Pain/etiology , Prostheses and Implants
14.
World Neurosurg ; 185: 60-70, 2024 May.
Article En | MEDLINE | ID: mdl-38325702

OBJECTIVE: Precise planning and execution is key for neuroendoscopic interventions, which can be based on different available aiding technologies. The aim of this retrospective study is to report a case-based use of guided neuroendoscopy and to develop a stratification algorithm for the available technologies. METHODS: We reviewed consecutive neuroendoscopic cases performed at our center from 2016 to 2018. We distinguished between patients receiving a new burr hole (group A) and those with a preexisting burr hole (group B). Case-specific technical requirements for procedure planning and execution, complication rate, surgical outcome, and possible subsequent surgery were evaluated. From this experience, a stratification system was developed to tailor the available guiding technologies. RESULTS: A total of 309 neuroendoscopic interventions in 243 patients were included in the present study. The cases included hydrocephalic (81.6%) and nonhydrocephalic (18.4%) conditions. The interventions were supported by coordinate-based (group A, n = 49; group B, n = 67), guide-based (group A, n = 42; group B, n = 0), ultrasound-guided (group A, n = 50; group B, n = 7), or navigated augmented reality-guided (group A, n = 85; group B, n = 9) techniques. The overall complication rate was 4.5%. Stratified by the surgical indication, fontanel status, entry point localization, presence of a preexisting burr hole, ventricular size, and number of targets, an approach toward image-guided neuroendoscopy is suggested. CONCLUSIONS: Planning and technical guidance is essential in neuroendoscopic procedures. The stratified decision-making algorithm for different available technologies aims to achieve lower cost and time consumption, which was found to be safe and efficient. Further investigations are warranted to deliver solid data on procedure efficiency.


Neuroendoscopy , Humans , Neuroendoscopy/methods , Retrospective Studies , Female , Male , Middle Aged , Adult , Aged , Adolescent , Neuronavigation/methods , Young Adult , Surgery, Computer-Assisted/methods , Child , Child, Preschool , Hydrocephalus/surgery , Hydrocephalus/diagnostic imaging
15.
Sensors (Basel) ; 24(3)2024 Jan 30.
Article En | MEDLINE | ID: mdl-38339612

Addressing conventional neurosurgical navigation systems' high costs and complexity, this study explores the feasibility and accuracy of a simplified, cost-effective mixed reality navigation (MRN) system based on a laser crosshair simulator (LCS). A new automatic registration method was developed, featuring coplanar laser emitters and a recognizable target pattern. The workflow was integrated into Microsoft's HoloLens-2 for practical application. The study assessed the system's precision by utilizing life-sized 3D-printed head phantoms based on computed tomography (CT) or magnetic resonance imaging (MRI) data from 19 patients (female/male: 7/12, average age: 54.4 ± 18.5 years) with intracranial lesions. Six to seven CT/MRI-visible scalp markers were used as reference points per case. The LCS-MRN's accuracy was evaluated through landmark-based and lesion-based analyses, using metrics such as target registration error (TRE) and Dice similarity coefficient (DSC). The system demonstrated immersive capabilities for observing intracranial structures across all cases. Analysis of 124 landmarks showed a TRE of 3.0 ± 0.5 mm, consistent across various surgical positions. The DSC of 0.83 ± 0.12 correlated significantly with lesion volume (Spearman rho = 0.813, p < 0.001). Therefore, the LCS-MRN system is a viable tool for neurosurgical planning, highlighting its low user dependency, cost-efficiency, and accuracy, with prospects for future clinical application enhancements.


Augmented Reality , Surgery, Computer-Assisted , Humans , Male , Female , Adult , Middle Aged , Aged , Neuronavigation/methods , Feasibility Studies , Tomography, X-Ray Computed , Lasers , Surgery, Computer-Assisted/methods , Imaging, Three-Dimensional/methods
16.
Childs Nerv Syst ; 40(5): 1603-1607, 2024 May.
Article En | MEDLINE | ID: mdl-38165414

Mucopolysaccharidosis type II (MPS II) results from the genetic deficiency of a lysosomal enzyme and is associated with central nervous system (CNS) dysfunction. In Japan, in addition to intravenous enzyme administration, intracerebroventricular enzyme delivery through the Ommaya reservoir has recently gained approval. Nevertheless, the ideal approach for safely implanting the reservoir into the narrow ventricles of infantile MPS II patients remains uncertain. In this report, we present two cases of successful reservoir placement in infantile MPS II patients using ultrasound guidance via the anterior fontanelle, coupled with flameless electromagnetic neuronavigation.


Cranial Fontanelles , Mucopolysaccharidosis II , Humans , Neuronavigation/methods , Electromagnetic Phenomena , Drug Delivery Systems/methods
17.
J Neurosurg Pediatr ; 33(4): 343-348, 2024 Apr 01.
Article En | MEDLINE | ID: mdl-38277648

OBJECTIVE: Neuronavigation is a useful adjunct for catheter placement during neurosurgical procedures for hydrocephalus or ventricular access. MRI protocols for navigation are lengthy and require sedation for young children. CT involves ionizing radiation. In this study, the authors introduce the clinical application of a 1-minute rapid MRI sequence that does not require sedation in young children and report their preliminary clinical experience using this technique in their pediatric population. METHODS: All patients who underwent ventricular catheter placement at a children's hospital using a rapid noncontrast MRI protocol, standard MRI, or head CT from July 2021 to August 2023 were included. Type of procedure, etiology of hydrocephalus, ventricle configuration and size, morphology of ventricles, need for adjunctive intraoperative ultrasound, duration of procedure, accuracy of catheter placement, and need for proximal revision within 90 days were retrospectively recorded and compared across imaging modalities. RESULTS: Sixty-eight patients underwent 83 procedures: 21 underwent CT navigation, 29 standard MRI, and 33 rapid MRI. Patients who received standard MRI more often had tumor etiology, while those who underwent CT and rapid MRI had posthemorrhagic etiology (χ2 = 13.04, p = 0.042). Intraoperative ultrasound was required for 1 patient in the standard MRI group and 1 patient in the CT group. There was no difference in procedure time across groups (p = 0.831). On multivariable analysis, procedure time differed by procedure type, where external ventricular drain placement and proximal revision were faster (p < 0.001 and p < 0.028, respectively). Proximal revision due to obstruction within 90 days occurred in 3 cases (in the same patient with complex loculated hydrocephalus) in the rapid MRI group and 2 cases in the CT group. CONCLUSIONS: Although this study was not powered for statistical inference, the authors report on the clinical use of a 1-minute rapid MRI sequence for neuronavigation in hydrocephalus or ventricular access surgery. There were no instances in which intraoperative ultrasound was required as an adjunct for procedures navigated with rapid MRI, and intraoperative time did not differ from that of standard navigation protocols.


Cerebral Ventricles , Hydrocephalus , Humans , Child , Child, Preschool , Retrospective Studies , Cerebral Ventricles/diagnostic imaging , Cerebral Ventricles/surgery , Neuronavigation/methods , Catheters/adverse effects , Magnetic Resonance Imaging , Hydrocephalus/diagnostic imaging , Hydrocephalus/etiology , Hydrocephalus/surgery , Ventriculoperitoneal Shunt/adverse effects
18.
Neurosurg Focus ; 56(1): E16, 2024 01.
Article En | MEDLINE | ID: mdl-38163340

OBJECTIVE: The surgical approach to lesions near eloquent areas continues to represent a challenge for neurosurgeons, despite all of the sophisticated tools currently used. The goal of surgery in eloquent areas is to maintain a good oncofunctional balance, that is, to preserve neurological function and ensure maximum tumor resection. Among all the available tools, extended reality (used to describe both virtual reality [VR] and mixed reality) is rapidly gaining a pivotal role in such delicate lesions, especially in preoperative planning, and recently, even during the surgical procedure. VR creates a completely new world in which only digital components are present. Augmented reality (AR), using software and hardware to introduce digital elements into the real-world environment, enhances the human experience. In addition, mixed reality, a more recent technique, combines VR and AR by projecting virtual objects into the real world, allowing the user to interact with them. METHODS: A systematic literature review of the last 23.5 years was conducted (January 2000-June 2023) to investigate and discuss all progress related to the emerging role and use of these new technologies (VR, AR, and mixed reality), particularly in eloquent area lesions as a pre- and/or intraoperative tool. RESULTS: Five hundred eighty-four published studies were identified. After removing duplicates and excluding articles that did not meet the inclusion criteria, 21 papers were included in the systematic review. The use of AR or VR was fully analyzed, considering their roles both intraoperatively and for surgical planning. CONCLUSIONS: The increasing use of such innovative technologies has completely changed the way to approach a lesion, using 3D visualization to foster a better understanding of its anatomical and vascular characteristics.


Augmented Reality , Surgery, Computer-Assisted , Virtual Reality , Humans , Surgery, Computer-Assisted/methods , Neuronavigation/methods , User-Computer Interface
19.
Neurosurg Focus ; 56(1): E7, 2024 01.
Article En | MEDLINE | ID: mdl-38163345

OBJECTIVE: This study aimed to rigorously assess the accuracy of mixed-reality neuronavigation (MRN) in comparison with magnetic neuronavigation (MN) through a comprehensive phantom-based experiment. It introduces a novel dimension by examining the influence of blue-green light (BGL) on MRN accuracy, a previously unexplored avenue in this domain. METHODS: Twenty-nine phantoms, each meticulously marked with 5-6 fiducials, underwent CT scans as part of the navigation protocol. A 3D model was then superimposed onto a 3D-printed plaster skull using a semiautomatic registration process. The study meticulously evaluated the accuracy of both navigation techniques by pinpointing specific markers on the plaster surface. Precise measurements were then taken using digital calipers, with navigation conducted under three distinct lighting conditions: indirect white light (referred to as no light [NL]), direct white light (WL), and BGL. The research enlisted two operators with distinct levels of experience, one senior and one junior, to ensure a comprehensive analysis. The study was structured into two distinct experiments (experiment 1 [MN] and experiment 2 [MRN]) conducted by the two operators. Data analysis focused on calculating average and median values within subgroups, considering variables such as the type of lighting, precision, and recording time. RESULTS: In experiment 1, no statistically significant differences emerged between the two operators. However, in experiment 2, notable disparities became apparent, with the senior operator recording longer times but achieving higher precision. Most significantly, BGL consistently demonstrated a capacity to enhance accuracy in MRN across both experiments. CONCLUSIONS: This study demonstrated the substantial positive influence of BGL on MRN accuracy, providing profound implications for the design and implementation of mixed-reality systems. It also emphasized that integrating BGL into mixed-reality environments could profoundly improve user experience and performance. Further research is essential to validate these findings in real-world settings and explore the broader potential of BGL in a variety of mixed-reality applications.


Augmented Reality , Neuronavigation , Humans , Neuronavigation/methods , Green Light , Tomography, X-Ray Computed , Skull
20.
Neurosurg Focus ; 56(1): E3, 2024 01.
Article En | MEDLINE | ID: mdl-38163347

OBJECTIVE: This study aimed to evaluate the impact of augmented reality intraoperative fiber tractography (AR-iFT) on extent of resection (EOR), motor functional outcome, and survival of patients with primary motor area (M1) intra-axial malignant tumors. METHODS: Data obtained from patients who underwent AR-iFT for M1 primary tumors were retrospectively analyzed and compared with those from a control group who underwent unaugmented reality intraoperative fiber tractography (unAR-iFT). A full asleep procedure with electrical stimulation mapping and fluorescein guidance was performed in both groups. The Neurological Assessment in Neuro-Oncology (NANO), Medical Research Council (MRC), and House-Brackmann grading systems were used for neurological, motor, and facial nerve assessment, respectively. Three-month postoperative NANO and MRC scores were used as outcome measures of the safety of the technique, whereas EOR and survival curves were related to its cytoreductive efficacy. In this study, p < 0.05 indicated statistical significance. RESULTS: This study included 34 and 31 patients in the AR-iFT and unAR-iFT groups, respectively. The intraoperative seizure rate, 3-month postoperative NANO score, and 1-week and 1-month MRC scores were significantly (p < 0.05) different and in favor of the AR-iFT group. However, no difference was observed in the rate of complications. Glioma had incidence rates of 58.9% and 51.7% in the study and control groups, respectively, with no statistical difference. Metastasis had a slightly higher incidence rate in the control group, without statistical significance, and the gross-total resection and near-total resection rates and progression-free survival (PFS) rate were higher in the study group. Overall survival was not affected by the technique. CONCLUSIONS: AR-iFT proved to be feasible, effective, and safe during surgery for M1 tumors and positively affected the EOR, intraoperative seizure rate, motor outcome, and PFS. Integration with electrical stimulation mapping is critical to achieve constant anatomo-functional intraoperative feedback. The accuracy of AR-iFT is intrinsically limited by diffusion tensor-based techniques, parallax error, and fiber tract crowding. Further studies are warranted to definitively validate the benefits of augmented reality navigation in this surgical scenario.


Augmented Reality , Brain Neoplasms , Motor Cortex , Humans , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/surgery , Brain Neoplasms/pathology , Retrospective Studies , Motor Cortex/diagnostic imaging , Motor Cortex/surgery , Neuronavigation/methods , Seizures/surgery
...