Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 16.452
1.
Vestn Oftalmol ; 140(2): 34-39, 2024.
Article Ru | MEDLINE | ID: mdl-38742496

PURPOSE: This study evaluates the accuracy of modern intraocular lens (IOL) calculation formulas using axial length (AL) data obtained by ultrasound biometry (UBM) compared to the third-generation SRK/T calculator. MATERIAL AND METHODS: The study included 230 patients (267 eyes) with severe lens opacities that prevented optical biometry, who underwent phacoemulsification (PE) with IOL implantation. IOL power calculation according to the SRK/T formula was based on AL and anterior chamber depth obtained by UBM (Tomey Biometer Al-100) and keratometry on the Topcon KR 8800 autorefractometer. To adapt AL for new generation calculators - Barrett Universal II (BUII), Hill RBF ver. 3.0 (RBF), Kane and Ladas Super Formula (LSF) - the retinal thickness (0.20 mm) was added to the axial length determined by UBM, and then the optical power of the artificial lens was calculated. The mean error and its modulus value were used as criteria for the accuracy of IOL calculation. RESULTS: A significant difference (p=0.008) in the mean IOL calculation error was found between the formulas. Pairwise analysis revealed differences between SRK/T (-0.32±0.58 D) and other formulas - BUII (-0.16±0.52 D; p=0.014), RBF (-0.17±0.51 D; p=0.024), Kane (-0.17±0.52 D; p=0.029), but not with the LSF calculator (-0.19±0.53 D; p=0.071). No significant differences between the formulas were found in terms of mean error modulus (p=0.238). New generation calculators showed a more frequent success in hitting target refraction (within ±1.00 D in more than 95% of cases) than the SRK/T formula (86%). CONCLUSION: The proposed method of adding 0.20 mm to the AL determined by UBM allows using this parameter in modern IOL calculation formulas and improving the refractive results of PE, especially in eyes with non-standard anterior segment structure.


Biometry , Lenses, Intraocular , Phacoemulsification , Refraction, Ocular , Humans , Biometry/methods , Male , Female , Aged , Middle Aged , Reproducibility of Results , Refraction, Ocular/physiology , Phacoemulsification/methods , Axial Length, Eye/diagnostic imaging , Lens Implantation, Intraocular/methods , Cataract/physiopathology , Cataract/diagnosis , Optics and Photonics/methods , Microscopy, Acoustic/methods
2.
Sci Rep ; 14(1): 10921, 2024 05 20.
Article En | MEDLINE | ID: mdl-38769346

Differentiation between leukocyte subtypes like monocytes and lymphocytes is essential for cell therapy and research applications. To guarantee the cost-effective delivery of functional cells in cell therapies, billions of cells must be processed in a limited time. Yet, the sorting rates of commercial cell sorters are not high enough to reach the required yield. Process parallelization by using multiple instruments increases variability and production cost. A compact solution with higher throughput can be provided by multichannel flow cytometers combining fluidics and optics on-chip. In this work, we present a micro-flow cytometer with monolithically integrated photonics and fluidics and demonstrate that both the illumination of cells, as well as the collection of scattered light, can be realized using photonic integrated circuits. Our device is the first with sufficient resolution for the discrimination of lymphocytes and monocytes. Innovations in microfabrication have enabled complete integration of miniaturized photonic components and fluidics in a CMOS-compatible wafer stack. In combination with external optics, the device is ready for the collection of fluorescence using the on-chip excitation.


Flow Cytometry , Lab-On-A-Chip Devices , Leukocytes , Humans , Flow Cytometry/methods , Flow Cytometry/instrumentation , Leukocytes/cytology , Optics and Photonics/instrumentation , Optics and Photonics/methods , Monocytes/cytology , Lymphocytes/cytology , Equipment Design
3.
BMC Ophthalmol ; 24(1): 198, 2024 Apr 26.
Article En | MEDLINE | ID: mdl-38671381

BACKGROUND: Postoperative performance, including best corrected distance visual acuity (BCDVA) and optical metrics (from the OQAS and iTrace devices), was compared among 4 different intraocular lenses (IOLs). METHODS: This prospective observational study included 104 eyes from 104 subjects who underwent cataract surgery combined with implantation of 4 different IOLs: monofocal (Mon) IOLs, segmental refractive (SegRef) IOLs, diffractive (Dif) IOLs and extended depth of focus (EDoF) IOLs. Postoperative BCDVA and optical metrics were collected at the 6th month. The OQAS optical metrics included the objective scattering index (OSI), Strehl ratio (SR), modulation transfer function (MTF) cut-off frequency, and predicted visual acuity (PVA); the iTrace optical metrics included blur/double vision, glare/halo, starburst, mixed focus, night myopia, and night hyperopia. RESULTS: There was no significant difference in BCDVA among the 4 groups (P = 0.059; power = 70.3%). Differences were observed in all OQAS optical metrics among the groups (all P < 0.001). Overall, Mon IOLs and EDoF IOLs exhibited better performance than Dif IOLs and SegRef IOLs. Starburst was the only iTrace optical metric that differed among the groups (P < 0.001): SegRef IOLs caused more starbursts than Mon IOLs (P = 0.001), Dif IOLs (P = 0.006) and EDoF IOLs (P < 0.001). Spearman rank correlation analysis was used to determine the relationships among the iTrace optical metrics, OQAS optical metrics and BCDVA: starburst was negatively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001); mixed focus was positively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001). CONCLUSIONS: Postoperative BCDVA and optical metrics varied among the different IOLs, which should be taken into account in the selection and management of IOLs for cataract patients. TRIAL REGISTRATION: This study was approved by the First Affiliated Hospital of Guangzhou Medical University Ethical Review Board (No. 50 2022).


Lenses, Intraocular , Visual Acuity , Humans , Prospective Studies , Visual Acuity/physiology , Female , Male , Aged , Middle Aged , Phacoemulsification , Refraction, Ocular/physiology , Lens Implantation, Intraocular , Prosthesis Design , Postoperative Period , Pseudophakia/physiopathology , Optics and Photonics
4.
ACS Biomater Sci Eng ; 10(5): 2784-2804, 2024 May 13.
Article En | MEDLINE | ID: mdl-38597279

Flexible electronics, applicable to enlarged health, AI big data medications, etc., have been one of the most important technologies of this century. Due to its particular mechanical properties, biocompatibility, and biodegradability, cocoon silk (or SF, silk fibroin) plays a key role in flexible electronics/photonics. The review begins with an examination of the hierarchical meso network structures of SF materials and introduces the concepts of meso reconstruction, meso doping, and meso hybridization based on the correlation between the structure and performance of silk materials. The SF meso functionalization was developed according to intermolecular nuclear templating. By implementation of the techniques of meso reconstruction and functionalization in the refolding of SF materials, extraordinary performance can be achieved. Relying on this strategy, particularly designed flexible electronic and photonic components can be developed. This review covers the latest ideas and technologies of meso flexible electronics and photonics based on SF materials/meso functionalization. As silk materials are biocompatible and human skin-friendly, SF meso flexible electronic/photonic components can be applied to wearable or implanted devices. These devices are applicable in human physiological signals and activities sensing/monitoring. In the case of human-machine interaction, the devices can be applicable in in-body information transmission, computation, and storage, with the potential for the combination of artificial intelligence and human intelligence.


Electronics , Humans , Animals , Biocompatible Materials/chemistry , Silk/chemistry , Fibroins/chemistry , Wearable Electronic Devices , Optics and Photonics , Bombyx
5.
J Refract Surg ; 40(4): e253-e259, 2024 Apr.
Article En | MEDLINE | ID: mdl-38593262

PURPOSE: To compare simulated keratometry (SimK) and total corneal power (TCP) in keratoconic eyes, to determine whether the differences are systematic and predictable and to evaluate an adjusted TCP-based formula for intraocular lens (IOL) power calculation. METHODS: In a consecutive series of keratoconic eyes, measurements of SimK, TCP, posterior keratometry, and anterior and posterior corneal asphericities (Q-values) were retrospectively collected. The difference between SimK and TCP was linearly correlated to the biometric parameters. In a separate sample of keratoconic eyes that had undergone cataract surgery, IOL power was calculated with the Barrett Universal II, Hoffer QST, Holladay 1, Kane, and SRK/T formulas using the SimK and an adjusted TCP power. The respective prediction errors were calculated. RESULTS: A total of 382 keratoconic eyes (271 patients) were enrolled. An increasing overestimation of SimK by TCP was detected from stage I to III, with a significant correlation between the SimK and TCP difference and SimK in the whole sample (P < .0001, r2 = 0.1322). Approximately 7% of cases presented an underestimation of SimK by TCP. IOL power calculation with the adjusted TCP improved outcomes, achieving a maximum of 80% of eyes with a prediction error within ±0.50 diopters with the Hoffer QST, Holladay 1, and Kane formulas. CONCLUSIONS: Overall, SimK overestimated TCP. Such a difference could not be predicted by any variable. The proposed TCP-adjustment formula (TCPadj = TCP + 0.56 diopters) in keratoconic eyes for IOL power calculation might be valuable for improving refractive outcomes. [J Refract Surg. 2024;40(4):e253-e259.].


Keratoconus , Lenses, Intraocular , Phacoemulsification , Humans , Keratoconus/diagnosis , Lens Implantation, Intraocular/methods , Retrospective Studies , Phacoemulsification/methods , Optics and Photonics , Refraction, Ocular , Biometry/methods
6.
Eye (Lond) ; 38(Suppl 1): 4-8, 2024 May.
Article En | MEDLINE | ID: mdl-38580743

OBJECTIVES: The purpose of this study is to evaluate the optical and expected clinical performance of a new refractive Extended Depth of Focus (EDF) intraocular lens (IOL) designed to maintain a monofocal-like dysphotopsia profile. METHODS: Simulated visual acuity (sVA) with varying defocus was calculated using the area under the Modulation Transfer Function measured in an average eye model and from computer simulations in eye models with corneal higher-order aberrations. Tolerance to defocus was evaluated using computer simulations of the uncorrected distance sVA under defocus. To evaluate the dysphotopsia profile, halo pictures obtained using an IOL-telescope, as well as simulated images in a realistic eye model under defocus were assessed. The results of the refractive EDF were compared to those of a diffractive EDF of the same platform. RESULTS: The refractive EDF IOL provides similar range of vision to the diffractive EDF IOL with the same distance, and similar intermediate and near sVA. The refractive EDF IOL provides the same tolerance to hyperopia as the diffractive EDF but more tolerance to myopia. Halo pictures and simulations showed that the refractive EDF provides comparable dysphotopsia profile to the monofocal IOL and better than the diffractive EDF. CONCLUSIONS: The results of this preclinical study in clinically relevant conditions show that the new refractive EDF IOL is expected to provide similar range of vision to the diffractive IOL of the same platform and higher tolerance to refractive errors. The refractive EDF provides a dysphotopsia profile that is better than the diffractive EDF and comparable to that of the monofocal IOL, also in the presence of residual refractive errors.


Computer Simulation , Lenses, Intraocular , Visual Acuity , Humans , Visual Acuity/physiology , Refraction, Ocular/physiology , Depth Perception/physiology , Prosthesis Design , Optics and Photonics , Vision Disorders/physiopathology , Lens Implantation, Intraocular/methods
7.
Ophthalmic Res ; 67(1): 248-256, 2024.
Article En | MEDLINE | ID: mdl-38527448

INTRODUCTION: This study aimed to determine the interchangeability of bilateral anterior chamber depth (ACD) in intraocular lens (IOL) power calculations for cataractous eyes and refractive outcomes using the unaffected fellow eye's ACD in subluxated crystalline lenses. METHODS: The predicted postoperative spherical equivalent (SE) calculated using the Kane formula with and without fellow eye's ACD in 202 cataract patients was compared. Refractive outcomes of the newer formulas (the Kane, Barrett Universal II [BUII], and Pearl-DGS formulas) with affected eye's ACD and with unaffected fellow eye's ACD were compared in 33 eyes with lens subluxation (the affected eye) undergoing in-the-bag IOL implantation. The SD of the prediction error (PE) was assessed using the heteroscedastic method. RESULTS: In 202 paired cataractous eyes, no marked ACD difference was found bilaterally; the predicted SE obtained without the fellow eye's ACD was comparable with that calculated with the fellow eye one (p = 0.90), with a mean absolute difference of 0.03 ± 0.03 D. With the affected eye AL, keratometry, and ACD, the median absolute error (MedAE) was 0.38-0.64 D, and the percentage of PE within ±0.50 D was 30.30-57.58%. The unaffected eye's ACD improved the results (MedAE, 0.35-0.49 D; the percentage of PE within ±0.50 D, 54.55-63.64%). The SDs of the BUII (0.82 D) and Pearl-DGS formulas (0.87 D) with the affected eye's ACD were significantly larger than those of the Kane and Pearl-DGS formulas (both 0.69 D) with the unaffected eye's ACD. CONCLUSION: Bilateral ACD was interchangeable in IOL power calculation for cataractous eyes when using the Kane formula. Unaffected eye's ACD in lieu of affected eye's ACD can enhance the accuracy of newer formulas in patients with unilateral subluxated lenses undergoing in-the-bag IOL implantation.


Anterior Chamber , Lens Subluxation , Lenses, Intraocular , Refraction, Ocular , Humans , Male , Female , Aged , Refraction, Ocular/physiology , Middle Aged , Lens Subluxation/surgery , Lens Subluxation/diagnosis , Lens Subluxation/physiopathology , Adult , Visual Acuity , Retrospective Studies , Optics and Photonics , Lens Implantation, Intraocular/methods , Biometry/methods , Aged, 80 and over
8.
J Cataract Refract Surg ; 50(6): 637-643, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38465836

PURPOSE: To quantify the angular dependence of monofocal intraocular lens (IOL) power. SETTING: Ophthalmic Biophysics Laboratory, Kallam Anji Reddy campus, L V Prasad Eye Institute, Hyderabad, India. DESIGN: Laboratory study. METHODS: Experiments were performed on IOLs from 2 different manufacturers (APPALENS 207, Appasamy Associates and SN60WF, Alcon Laboratories, Inc.). IOL powers ranged from 17 to 25 diopters (D). The IOLs were mounted in a fluid-filled chamber, and the on-axis and off-axis powers were measured using a laser ray tracing system over the central 3 mm zone with delivery angles ranging from -30 to +30 degrees in 5-degree increments. The position of the best focus was calculated for each IOL at each angle. The angular dependence of IOL power was compared with theoretical predictions. RESULTS: Peripheral defocus increased significantly with increasing incidence angle and power. The peripheral defocus at ±30 degrees increased from 5.8 to 8.5 D when the power increased from 17.5 to 24.5 D for APPALENS 207 and from 4.9 to 7.4 D when the power increased from 17 to 25 D for SN60WF. The mean difference between the measured and theoretical tangential power at ±30 degrees was 0.50 ± 0.16 D for the APPALENS 207 and -0.40 ± 0.10 D for the SN60WF, independent of IOL power. CONCLUSIONS: IOLs introduce a significant amount of peripheral defocus which varies significantly with IOL power and design. Given that peripheral defocus is related to lens power, replacement of the crystalline lens (approximately 24 D) with an IOL will produce a significant difference in peripheral defocus profile after surgery.


Lenses, Intraocular , Optics and Photonics , Humans , Refraction, Ocular/physiology , Prosthesis Design
9.
Am J Ophthalmol ; 262: 237-245, 2024 Jun.
Article En | MEDLINE | ID: mdl-38452920

PURPOSE: To investigate the relationship between effective lens position (ELP) and patient characteristics, and to further develop a new intraocular lens (IOL) calculation formula for cataract patients with previous pars plana vitrectomy (PPV). DESIGN: Cross-sectional study. METHODS: A total of 2793 age-related cataract patients (group 1) and 915 post-PPV cataract patients (group 2) who underwent phacoemulsification with IOL implantation were included. The ELP of 2 groups was compared and the association between ELP and patient characteristics was further evaluated using standardized multivariate regression coefficients. An ensemble artificial intelligence-based ELP prediction model was developed using a training set of 810 vitrectomized eyes, and a thick-lens IOL formula (LISA-PPV) was constructed and compared with 7 existing formulas on an external multi-center testing set of 105 eyes. RESULTS: Compared to eyes with age-related cataract, vitrectomized eyes showed a similar ELP distribution (P = .19), but different standardized coefficients of preoperative biometry for ELP. The standardized coefficients also varied with the type of vitreous tamponade, history of scleral buckling, and ciliary sulcus IOL implantation. The LISA-PPV formula showed the lowest mean and median absolute prediction error (MAE: 0.63 D; MedAE: 0.44 D), and the highest percentages of eyes within ±0.5 D of prediction error (57.14%) in the testing dataset. CONCLUSIONS: The ELP prediction required optimization specifically for vitrectomized eyes based on their biometric and surgical characteristics. The LISA-PPV formula is a useful and accurate tool for determining IOL power in cataract patients with previous PPV (available at http://ppv-iolcalculator.com/).


Artificial Intelligence , Biometry , Lens Implantation, Intraocular , Lenses, Intraocular , Optics and Photonics , Phacoemulsification , Vitrectomy , Humans , Cross-Sectional Studies , Male , Female , Aged , Vitrectomy/methods , Biometry/methods , Middle Aged , Visual Acuity/physiology , Aged, 80 and over , Refraction, Ocular/physiology , Cataract/physiopathology , Cataract/complications , Retrospective Studies
10.
Biosens Bioelectron ; 254: 116231, 2024 Jun 15.
Article En | MEDLINE | ID: mdl-38513540

Strong light-matter coupling between molecules and electromagnetic field lead to the formation of hybrid polaritonic states for surface enhanced Raman scattering (SERS) detection. However, owing to the inefficient interaction between zero-point fluctuations of photons/plasmons and molecular electronic transitions, the Raman enhancement is limited in relative low levels. Here, we propose and fabricate a TiOx/Cu2-xSe/R6G nanocavity based photonic-plasmonic-polaritonic resonator for single molecular SERS detection. Through precisely matching the energy levels of illuminated photon, generated plasmon, and molecular polariton, an extremely high Raman enhancement factor of 2.6 × 109 is implemented. The rationally designed SERS substrate allows sensitive detection of miRNA-21 in single molecular level with a detection limit of 1.58 aM. The hybrid SERS mechanism both from electromagnetic and chemical perspectives in this photonic-plasmonic-polaritonic resonance strategy provides insight into polaritonic semiconductor systems, thus paving the way for new experimental possibilities in light-matter hybrids.


Biosensing Techniques , MicroRNAs , Nanotechnology , Optics and Photonics , Spectrum Analysis, Raman
11.
Comput Biol Med ; 173: 108245, 2024 May.
Article En | MEDLINE | ID: mdl-38531253

PURPOSE: This study aimed to evaluate and optimize intraocular lens (IOL) power selection for cataract patients with high axial myopia receiving trifocal IOLs. DESIGN: A multi-center, retrospective observational case series was conducted. Patients having an axial length ≥26 mm and undergoing cataract surgery with trifocal IOL implanted were studied. METHODS: Preoperative biometric and postoperative outcome data from 139 eyes were collected to train and test various machine learning (ML) models (support vector machine, linear regression, and stacking regressor) using five-fold cross-validation. The models' performance was further validated externally using data from 48 eyes enrolled from other hospitals. Performance of seven IOL calculation formulas (BUII, Kane, EVO, K6, DGS, Holladay I, and SRK/T) were examined with and without ML models. RESULTS: The results of cross-validation revealed improvements across all IOL calculation formulas, especially for K6 and Holladay I. The model increased the percentage of eyes with a prediction error (PE) within ±0.50 D from 71.94% to 79.14% for K6, and from 35.25% to 51.80% for Holladay I. In external validation involving 48 patients from other centers, six out of seven formulas demonstrated a reduction in the mean absolute error (MAE). K6's PE within ±0.50 D improved from 62.50% to 77.08%, and Holladay I from 16.67% to 58.33%. CONCLUSIONS: In this study, we conducted a comprehensive evaluation of seven IOL power calculation formulas in high axial myopia cases and explored the effectiveness of the Stacking Regressor model in augmenting their accuracy. Of these formulas, K6 and Holladay I exhibited the most significant improvements, suggesting that integrating ML may have varying levels of effectiveness across different formulas but holds substantial promise in improving the predictability of IOL power calculations in patients with long eyes.


Cataract , Lenses, Intraocular , Myopia , Humans , Myopia/surgery , Optics and Photonics , Refraction, Ocular , Retrospective Studies
12.
Cells ; 13(5)2024 Feb 29.
Article En | MEDLINE | ID: mdl-38474397

This Editorial is the preface for the topical collection of "Computational Imaging for Biophotonics and Biomedicine", which collates the 12 contributions listed in Table 1 [...].


Optics and Photonics
13.
BMC Ophthalmol ; 24(1): 126, 2024 Mar 19.
Article En | MEDLINE | ID: mdl-38504225

BACKGROUND: This study evaluates the impact of corneal power on the accuracy of 14 newer intraocular lens (IOL) calculation formulas in cataract surgery. The aim is to assess how these formulas perform across different corneal curvature ranges, thereby guiding more precise IOL selection. METHODS: In this retrospective case series, 336 eyes from 336 patients who underwent cataract surgery were studied. The cohort was divided into three groups according to preoperative corneal power. Key metrics analyzed included mean prediction error (PE), standard deviation of PE (SD), mean absolute prediction error (MAE), median absolute error (MedAE), and the percentage of eyes with PE within ± 0.25 D, 0.50 D, ± 0.75 D, ± 1.00 D and ± 2.00 D. RESULTS: In the flat K group (Km < 43 D), VRF-G, Emmetropia Verifying Optical Version 2.0 (EVO2.0), Kane, and Hoffer QST demonstrated lower SDs (± 0.373D, ± 0.379D, ± 0.380D, ± 0.418D, respectively) compared to the VRF formula (all P < 0.05). EVO2.0 and K6 showed significantly different SDs compared to Barrett Universal II (BUII) (all P < 0.02). In the medium K group (43 D ≤ Km < 46 D), VRF-G, BUII, Karmona, K6, EVO2.0, Kane, and Pearl-DGS recorded lower MAEs (0.307D to 0.320D) than Olsen (OLCR) and Castrop (all P < 0.03), with RBF3.0 having the second lowest MAE (0.309D), significantly lower than VRF and Olsen (OLCR) (all P < 0.05). In the steep K group (Km ≥ 46D), RBF3.0, K6, and Kane achieved significantly lower MAEs (0.279D, 0.290D, 0.291D, respectively) than Castrop (all P < 0.001). CONCLUSIONS: The study highlights the varying accuracy of newer IOL formulas based on corneal power. VRF-G, EVO2.0, Kane, K6, and Hoffer QST are highly accurate for flat corneas, while VRF-G, RBF3.0, BUII, Karmona, K6, EVO2.0, Kane, and Pearl-DGS are recommended for medium K corneas. In steep corneas, RBF3.0, K6, and Kane show superior performance.


Cataract Extraction , Cataract , Lenses, Intraocular , Phacoemulsification , Humans , Retrospective Studies , Cornea , Eye, Artificial , Biometry , Refraction, Ocular , Optics and Photonics , Axial Length, Eye
14.
Sci Rep ; 14(1): 6343, 2024 03 15.
Article En | MEDLINE | ID: mdl-38491195

The in vivo diagnosis and monitoring of pulmonary disorders (caused for example by emphysema, Covid-19, immature lung tissue in infants) could be effectively supported by the non-invasive sensing of the lung through light. With this purpose, we investigated the feasibility of probing the lung by means of time-resolved diffuse optics, leveraging the increased depth (a few centimeters) attained by photons collected after prolonged propagation time (a few nanoseconds). We present an initial study that includes measurements performed on 5 healthy volunteers during a breathing protocol, using a time-resolved broadband diffuse optical spectroscopy system. Those measurements were carried out across the spectral range of 600-1100 nm at a source-detector distance of 3 cm, and at 820 nm over a longer distance (7-9 cm). The preliminary analysis of the in vivo data with a simplified homogeneous model revealed a maximum probing depth of 2.6-3.9 cm, suitable for reaching the lung. Furthermore, we observed variations in signal associated with respiration, particularly evident at long photon propagation times. However, challenges stemming from both intra- and inter-subject variability, along with inconsistencies potentially arising from conflicting scattering and absorption effects on the collected signal, hindered a clear interpretation. Aspects that require further investigation for a more comprehensive understanding are outlined.


Optics and Photonics , Photons , Humans , Spectrum Analysis/methods , Lung/diagnostic imaging
15.
J Refract Surg ; 40(3): e156-e163, 2024 Mar.
Article En | MEDLINE | ID: mdl-38466761

PURPOSE: To assess the performance of the Camellin-Calossi formula in eyes with prior myopic laser vision correction. METHODS: This was a retrospective case series. Patients included had a history of uncomplicated myopic laser vision correction and cataract surgery. The primary outcome measures were cumulative distribution of absolute refractive prediction error, absolute refractive prediction error, and refractive prediction error. These parameters were estimated post-hoc using the Camellin-Calossi, Shammas, Haigis-L, Barrett True-K with or without history, Masket, and Modified Masket formulas and their averages starting from biometric data, clinical records, postoperative refraction, and intraocular lens power implanted. RESULTS: Seventy-seven eyes from 77 patients were included. The Camellin-Calossi, Shammas, Haigis-L, Barrett True-K No History, Masket, Modified Masket, and Barrett True-K formulas showed a median absolute refractive error (interquartile range) of 0.25 (0.53), 0.51 (0.56), 0.44 (0.65), 0.45 (0.59), 0.40 (0.61), 0.60 (0.70), and 0.55 (0.76), respectively. The proportion of eyes with an absolute refractive error of ±0.25, 0.50, 0.75, 1.00, 1.50, and 2.00 diopters (D) for the Camellin-Calossi formula was 54.5%, 72.7%, 85.7%, 92.2%, 98.7%, and 100%, respectively. The cumulative distribution of the Camellin-Calossi formula showed the best qualitative performances when compared to the others. A statistically significant difference was identified with all of the others except the Haigis-L using a threshold of 0.25, with the Shammas, Modified Masket, and Barrett True-K at a threshold of 0.50 D and the Barrett True-K and Modified Masket at a threshold of 1.00 D. CONCLUSIONS: The Camellin-Calossi formula is a valid option for intraocular lens power calculation in eyes with prior myopic laser vision correction. [J Refract Surg. 2024;40(3):e156-e163.].


Keratomileusis, Laser In Situ , Lenses, Intraocular , Myopia , Phacoemulsification , Humans , Lens Implantation, Intraocular , Retrospective Studies , Refraction, Ocular , Myopia/surgery , Biometry , Lasers , Optics and Photonics
16.
J Biomed Opt ; 29(3): 036502, 2024 Mar.
Article En | MEDLINE | ID: mdl-38515831

Significance: The reprojection setup typical of oblique plane microscopy (OPM) limits the effective aperture of the imaging system, and therefore its efficiency and resolution. Large aperture system is only possible through the use of custom specialized optics. A full-aperture OPM made with off the shelf components would both improve the performance of the method and encourage its widespread adoption. Aim: To prove the feasibility of an OPM without a conventional reprojection setup, retaining the full aperture of the primary objective employed. Approach: A deformable lens based remote focusing setup synchronized with the rolling shutter of a complementary metal-oxide semiconductor detector is used instead of a traditional reprojection system. Results: The system was tested on microbeads, prepared slides, and zebrafish embryos. Resolution and pixel throughput were superior to conventional OPM with cropped apertures, and comparable with OPM implementations with custom made optical components. Conclusions: An easily reproducible approach to OPM imaging is presented, eliminating the conventional reprojection setup and exploiting the full aperture of the employed objective.


Lenses , Optical Devices , Animals , Microscopy/methods , Zebrafish , Optics and Photonics , Oxides
17.
ACS Sens ; 9(4): 1799-1808, 2024 Apr 26.
Article En | MEDLINE | ID: mdl-38549498

Photonic technologies promise to deliver quantitative, multiplex, and inexpensive medical diagnostic platforms by leveraging the highly scalable processes developed for the fabrication of semiconductor microchips. However, in practice, the affordability of these platforms is limited by complex and expensive sample handling and optical alignment. We previously reported the development of a disposable photonic assay that incorporates inexpensive plastic micropillar microfluidic cards for sample delivery. That system as developed was limited to singleplex assays due to its optical configuration. To enable multiplexing, we report a new approach addressing multiplex light I/O, in which the outputs of individual grating couplers on a photonic chip are mapped to fibers in a fiber bundle. As demonstrated in the context of detecting antibody responses to influenza and SARS-CoV-2 antigens in human serum and saliva, this enables multiplexing in an inexpensive, disposable, and compact format.


Biosensing Techniques , COVID-19 , SARS-CoV-2 , Humans , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , SARS-CoV-2/immunology , COVID-19/diagnosis , COVID-19/immunology , Saliva/chemistry , Antibodies, Viral/immunology , Antibodies, Viral/blood , Optics and Photonics , Lab-On-A-Chip Devices
18.
Curr Eye Res ; 49(6): 605-614, 2024 Jun.
Article En | MEDLINE | ID: mdl-38363071

PURPOSE: To investigate the influence of lens thickness (LT) on accuracy of Kane, Hill-RBF 3.0 Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO), and Pearl-DGS formulas in eyes with different axial lengths (AL). METHODS: The prospective cohort study was conducted at Eye and ENT Hospital of Fudan University. Patients who had uneventful cataract surgery between March 2021 and July 2023 were recruited. Manifest refraction was conducted two-month post-surgery. Eyes were divided into 4 groups based on AL: short (<22mm), medium (22-24.5 mm), medium long (24.5-26mm) and very long (≥26mm). In each AL group, eyes were then divided into 3 subgroups based on the LT measured with IOLmaster700: thin (<4.5 mm), medium (4.5-5.0 mm), and thick (≥ 5 mm). The influence of LT on accuracy of Kane, Hill-RBF 3.0, BUII, EVO, and Pearl-DGS formulas were investigated in each AL group. RESULTS: A total of 327 eyes from 327 patients were analyzed, with 64, 102, 73 and 88 eyes in each AL group, respectively. In eyes with AL < 24.5 mm, myopic PE was significantly associated with greater LT using all the 5 formulas (all p < 0.05). Backward stepwise multivariate regression analyses revealed that LT was an important influencing factor for PE in all 5 formulas, particularly in eyes with AL <24.5 mm. In eyes with AL <24.5 mm and LT > 5.0 mm, PE of all 5 formulas calculated with the optional parameter LT were more myopic than those calculated without LT. CONCLUSIONS: Thicker LT was associated with more myopic PE among eyes with AL <24.5 mm when using all 5 formulas. Further optimization of current formulas is necessary, especially for eyes with short AL and thick LT.


Axial Length, Eye , Biometry , Emmetropia , Lens, Crystalline , Myopia, Degenerative , Refraction, Ocular , Humans , Prospective Studies , Male , Female , Refraction, Ocular/physiology , Axial Length, Eye/pathology , Emmetropia/physiology , Biometry/methods , Middle Aged , Lens, Crystalline/pathology , Lens, Crystalline/diagnostic imaging , Aged , Myopia, Degenerative/diagnosis , Myopia, Degenerative/physiopathology , Visual Acuity , Optics and Photonics , Lenses, Intraocular , Lens Implantation, Intraocular , Reproducibility of Results , Myopia/physiopathology , Myopia/diagnosis
19.
Opt Express ; 32(2): 2631-2643, 2024 Jan 15.
Article En | MEDLINE | ID: mdl-38297787

Among various specifications of near eye display (NED) devices, a compact formfactor is essential for comfortable user experience but also the hardest one to accomplish due to the slowest progresses. A pinhole/pinlight array based light-field (LF) technique is considered as one of the candidates to achieve that goal without thicker and heavier refractive optics. Despite those promising advantages, however, there are critical issues, such as dark spots and contrast distortion, which degrade the image quality because of the vulnerability of the LF retinal image when the observer's eye pupil size changes. Regardless of previous attempts to overcome those artifacts, it was impossible to resolve both issues due to their trade-off relation. In this paper, in order to resolve them simultaneously, we propose a concept of multiplexed retinal projections to integrate the LF retinal image through rotating transitions of refined and modulated elemental images for robust compensation of eye pupil variance with improved conservation of contrast distribution. Experimental demonstrations and quantitative analysis are also provided to verify the principle.


Pupil , Retina , Refraction, Ocular , Optics and Photonics , Photic Stimulation
20.
Sci Rep ; 14(1): 4228, 2024 02 20.
Article En | MEDLINE | ID: mdl-38378801

This study evaluates the accuracy of a newly developed intraocular lens (IOL) power calculation method that applies four different IOL power calculation formulas according to 768 biometric subgroups based on keratometry, anterior chamber depth, and axial length. This retrospective cross-sectional study was conducted in at Korea University Ansan Hospital. A total of 1600 eyes from 1600 patients who underwent phacoemulsification and a ZCB00 IOL in-the-bag implantation were divided into two datasets: a reference dataset (1200 eyes) and a validation dataset (400 eyes). Using the reference dataset and the results of previous studies, the Eom IOL power calculator was developed using 768 biometric subgroups. The median absolute errors (MedAEs) and IOL Formula Performance Indexes (FPIs) of the Barrett Universal II, Haigis, Hoffer Q, Holladay 1, Ladas Super, SRK/T, and Eom formulas using the 400-eye validation dataset were compared. The MedAE of the Eom formula (0.22 D) was significantly smaller than that of the other four formulas, except for the Barrett Universal II and Ladas Super formulas (0.24 D and 0.23 D, respectively). The IOL FPI of the Eom formula was 0.553, which ranked first, followed by the Ladas Super (0.474), Barrett Universal II (0.470), Holladay 1 (0.444), Hoffer Q (0.396), Haigis (0.392), and SRK/T (0.361) formulas. In conclusion, the Eom IOL power calculator developed in this study demonstrated similar or slightly better accuracy than the Barrett Universal II and Ladas Super formulas and was superior to the four traditional IOL power calculation formulas.


Lenses, Intraocular , Phacoemulsification , Humans , Refraction, Ocular , Visual Acuity , Retrospective Studies , Cross-Sectional Studies , Axial Length, Eye , Phacoemulsification/methods , Biometry/methods , Optics and Photonics
...